Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Design Pressure Report (Gregory Blomberg) - Florida Window & Door
Property Information Owner:Gregory Blomberg Address:586 Beach Ave Port Saint Lucie, FL 34952 Building Information Wind Zone:165 MPH. Exposure Category:D Minimum Building Dimension:30 ft. Mean Roof Height:12 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 120 80 7 37.9 -47.2 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1