Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTS BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL37784-R2 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Mule-Hide Products Co., Inc. Address/Phone/Email 1195 Prince Hall Dr Beloit, WI 53511-5481 (608) 365-3111 Ext 809 lindar@nemoetc.com Authorized Signature Timothy McFarland lindar@nemoetc.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Zachary R. Priest Florida License PE-74021 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/31/2024 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL37784_R2_COI_MHP21001.3a 2020 FBC Eval Underlayments FINAL.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D 1623 2017 ASTM D 1970 2015 ASTM D 2626 2004 ASTM D 4601 2004 FM 4474 2011 TAS 103 2020 TAS 110 2000 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/12/2021 Date Validated 08/15/2021 Date Pending FBC Approval 08/19/2021 Date Approved 10/12/2021 Date Revised 10/13/2021 Summary of Products FL #Model, Number or Name Description 37784.1 Base Sheets Shur-Gard #40 Base Sheet, ASTM D 2626, & F/G Base Sheet, ASTM D 4601, Type II Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Installation Instructions FL37784_R2_II_MHP21001.3b 2020 FBC Eval Underlayments FINAL.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL37784_R2_AE_MHP21001.3b 2020 FBC Eval Underlayments FINAL.pdf Created by Independent Third Party: Yes 37784.2 Shur-Gard Underlayments ASTM D 1970 self-adhered underlayments Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-90 Other: See evaluation report for limits of use. Installation Instructions FL37784_R2_II_MHP21001.3a 2020 FBC Eval Underlayments FINAL.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL37784_R2_AE_MHP21001.3a 2020 FBC Eval Underlayments FINAL.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: CREEK Technical Services, LLC MHP21001.3a FL37784-R2 Page 1 of 5 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. Registry No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020) Manufacturer: MULE-HIDE PRODUCTS CO., INC. Issued August 12, 2021 1195 Prince Hall Dr Beloit, WI 53511 (800) 786-1492 www.mulehide.com Manufacturing Location: Pryor, OK Quality Assurance: Keystone Certifications ,Inc. (QUA1824) SCOPE Category: Roofing Subcategory: Underlayments Code Edition: Florida Building Code, 7th Edition (2020) including High-Velocity Hurricane Zones (HVHZ) Code Sections: 1507.1.1, 1507.3.3, 1523.1.1, 1523.6.5.2.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) GAPR-014-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) GAPR-018-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) GAPR-029-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) GAPR-030-02-01 ASTM D 1623 2017 PRI Construction Materials Technologies (TST5878) GAPR-034-02-01 ASTM D 1623 2017 PRI Construction Materials Technologies (TST5878) GAPR-034-02-01.1 TAS 103 2020 PRI Construction Materials Technologies (TST5878) GAPR-034-02-02 TAS 110 2000 PRI Construction Materials Technologies (TST5878) 1047T0001 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) 1047T0004.1 TAS 110 TAS 103 2000 2020 PRI Construction Materials Technologies (TST5878) 1047T0011 TAS 110 TAS 103 2000 2020 PRI Construction Materials Technologies (TST5878) 1047T0012 TAS 110 2000 PRI Construction Materials Technologies (TST5878) 1047T0016 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) 1047T0017 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) 1047T0018.1 TAS 103 2020 PRI Construction Materials Technologies (TST5878) 1047T0029 ASTM D 1623 TAS 103 2017 2020 PRI Construction Materials Technologies (TST5878) 1047T0035 ASTM D 1623 TAS 103 2017 2020 PRI Construction Materials Technologies (TST5878) 1047T0038 ASTM D 7379 2008 (2015) PRI Construction Materials Technologies (TST5878) 1047T0046 UL1897 ASTM D 903 2012 1998(2010) PRI Construction Materials Technologies (TST5878) 1047T0040 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) 1047T0041 TAS 103 2020 PRI Construction Materials Technologies (TST5878) 1047T0047A ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) 1047T0047B ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) 1047T0047C ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) 1047T0049 ANSI/FM 4474 2011 A CREEK Technical Services, LLC MHP21001.3a FL37784-R2 Page 2 of 5 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. MULE-HIDE PRODCTS Shur-Gard Underlayments PRODUCT DESCRIPTION AND LIMITS OF USE Shur-Gard MU Force HT Shur-Gard MU Force HT is an ASTM D 1970, TAS 103, and FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition compliant self-adhered underlayment constructed of a SBS polymer modified asphalt top coating and a polymer film. The product is supplied in rolls having nominal dimensions of 39 3/8-in. x 66-ft. Exposure on the roof deck shall be limited to a maximum 180 days. Tiles shall be placed on battens for all roof slopes. Shur-Gard MU Ultra HT Shur-Gard MU Ultra HT is a nominal 60-mil thick ASTM D 1970 self-adhered underlayment constructed of a dual SBS polymer formulation and a non-woven, synthetic surface. The product is supplied in rolls having nominal dimensions of 36-in, x 67-ft. Exposure on the roof deck shall be limited to a maximum 120 days. Shur-Gard TU Force HT Shur-Gard TU Force HT is a nominal 80-mil thick ASTM D 1970, TAS 103, and FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition compliant self-adhered underlayment constructed of a dual SBS polymer formulation and a non-woven, polyester top surface. The product is supplied in 2 sq. rolls with nominal dimensions of 39 3/8-in x 66-ft. Exposure on the roof deck shall be limited to a maximum 180 days. The maximum roof slope shall be 6:12 when the roof tiles are placed directly on the underlayment. Tiles shall be placed on battens for roof slopes greater than 6:12. Shur-Gard TU Ultra HT Shur-Gard TU Ultra HT is a nominal 80-mil thick ASTM D 1970, TAS 103, and FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition self-adhered underlayment constructed of a dual SBS polymer formulation and a non- woven, polyester reinforced top surface. The product is supplied in 2 sq. rolls with nominal dimensions of 39 3/8-in x 66-ft. Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when the roof tiles are placed directly on the under layment. Tiles shall be placed on battens for roof slopes greater than 6:12. A CREEK Technical Services, LLC MHP21001.3a FL37784-R2 Page 3 of 5 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. MULE-HIDE PRODCTS Shur-Gard Underlayments PRODUCT APPLICATION Min. Roof Slope: 2:12 in accordance with the FBC Roof Deck: Shall be in accordance with the FBC requirements In the non-HVHZ, the following roof deck substrates are permitted for direct deck applications: Underlayment Plywood Primed Plywood Primed OSB Concrete Primed Concrete Shur-Gard MU Force HT Y Y N Y Y Shur-Gard MU Ultra HT Y N N N N Shur-Gard TU Force HT Y Y Y N Y Shur-Gard TU Ultra HT Y Y N Y Y Application: All underlayments shall be installed in accordance with the FBC and the manufacturer’s installation requirements. Substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the substrate shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3 - 5 minutes. The Shur-Gard underlayments shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the substrate. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with 4 ” headlaps (MetalGuard and Rain & Ice only) or 3” headlaps (TileGuard) and minimum 6” end laps staggered min. 6-ft.from preceding course. Shur-Gard TU Force HT end laps shall be sealed with Mule- Hide #420 Mod Bit Adhesive – Brush Grade or Mule-Hide #421 Mod Bit Flashing Adhesive – Trowel Grade. In the HVHZ, the Shur-Gard underlayments shall be installed over one of more plies of ASTM D 226 Type II or ASTM D 2626 organic felt with minimum 4” headlaps and minimum 6” endlaps in accordance with FBC Section 1518.3. It is permissible to backnail the Shur-Gard underlayments 12-inches o.c. within the headlaps (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Min. Application Temperature: 40°F and rising; Contact the manufacturer when installing at temperatures below the minimum application temperature. Roof Coverings: All Shur-Gard underlayments are permitted to be used with mechanically fastened metal roofing, slate shingles, asphalt shingles, photovoltaic shingles, and composite plastic shingles in accordance with the FBC. Shur-Gard MU Force HT is permitted to be used with mechanically fastened clay and concrete tiles set on battens only in accordance with the FBC. Shur-Gard TU Ultra HT is permitted to be used with mechanically fastened clay and concrete tiles in accordance with the FBC. Shur-Gard TU Force HT is permitted to be used with mechanically fastened clay and concrete roof tiles or clay and concrete roof tiles set in the following roof tile adhesive in accordance with the FBC. 1. DuPont TILE BONDTM Roof Tile Adhesive 2. DAP Touch’n Seal Storm Bond Roof Tile Adhesive 3. ICP Adhesives Polyset AH-160 A CREEK Technical Services, LLC MHP21001.3a FL37784-R2 Page 4 of 5 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. MULE-HIDE PRODCTS Shur-Gard Underlayments WIND RESISTANCE OF ROOF TILE UNDERLAYMENT SYSTEMS The Allowable Design Pressures below shall be used in accordance with the FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition for the selected underlayment system. The Allowable Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. System No. 1 Direct Deck application Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24” o.c. Underlayment: Shur-Gard MU Force HT, Shur-Gard TU Ultra HT or Shur-Gard TU Force HT shall be self-adhered to the deck in accordance with manufacturer’s installation instructions. The underlayment may be optionally backnailed along the selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through optionally primed, 32ga. x 1-5/8-inch Ø tin caps spaced 12” o.c. The applied underlayment shall be rolled with a minimum 75lb steel roller immediately following application. Allowable Design Pressure: -90 psf System No. 2 Direct Deck application Roof Deck: Concrete primed with ASTM D 41 primer Underlayment: Shur-Gard MU Force HT, Shur-Gard TU Ultra HT or Shur-Gard TU Force HT shall be self-adhered to the deck in accordance with manufacturer’s installation instructions. The applied underlayment shall be rolled with a minimum 75lb steel roller immediately following application. Allowable Design Pressure: -67.5 psf GENERAL LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer’s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 3) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 4) All headlaps shall be installed to shed water from the deck. 5) The underlayment may be used as described in other current FBC product approval documents. 6) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 7) All products listed in this report shall be manufactured under a quality assurance progr am in compliance with Rule 61G20-3. A CREEK Technical Services, LLC MHP21001.3a FL37784-R2 Page 5 of 5 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. MULE-HIDE PRODCTS Shur-Gard Underlayments COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 7th Edition (2020) including High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distri buting products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT This item has been digitally signed and sealed by Zachary R. Priest, PE, on 8/12/2021. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 2021.08.12 13:59:18 -04'00'