Loading...
HomeMy WebLinkAboutTri-Built Underlayment NOA12/7/21, 9:50 AM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtDQ1YvhxNfJqGNYw2SlyjWsijWc%2fsUEu7i0vOVs7IRvA%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL34539 Application Type New Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Beacon Sales Acquisitions, Inc. c/o Owens Corning Roofing and Asphalt LLC Address/Phone/Email 1 Owens Corning Parkway Toledo, OH 43657 (740) 587-3562 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Zachary R. Priest Florida License PE-74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 12/31/2024 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL34539_R0_COI_OCR20001 2020 FBC Eval TRI-BUILT Granular.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D 1970 2015 ASTM D 226 2009 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D 12/7/21, 9:50 AM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtDQ1YvhxNfJqGNYw2SlyjWsijWc%2fsUEu7i0vOVs7IRvA%3d%3d 2/2 Date Submitted 10/14/2020 Date Validated 10/15/2020 Date Pending FBC Approval 10/25/2020 Date Approved 12/16/2020 Summary of Products FL #Model, Number or Name Description 34539.1 TRI-BUILT Granular Underlayment A self-adhered underlayment used as an alternative to ASTM D 226, Type II roofing felt. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Installation Instructions FL34539_R0_II_OCR20001 2020 FBC Eval TRI-BUILT Granular.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL34539_R0_AE_OCR20001 2020 FBC Eval TRI-BUILT Granular.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: CREEK Technical Services, LLC OCR20001 FL34539 Page 1 of 3 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020) Manufacturer: BEACON SALES ACQUISITIONS, INC. Issued October 14, 2020 c/o OWENS CORNING ROOFING AND ASPHALT LLC 1 Owens Corning Parkway Toledo, OH 43657 (800) 438-7465 www.owenscorning.com Manufacturing Location: Houston, TX Brentwood, NH Quality Assurance: PRI Construction Materials Technologies, LLC (QUA9110) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1, 1507.1.1.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST6049) OCF-294-02-01 ICC-ES AC 1881 ICC-ES AC 48 2012 2012 PRI Construction Materials Technologies (TST6049) OCF-338-02-01 ASTM D 1970 2015a 1Determined to be equivalent to ASTM D 226-09, Type II PRODUCT DESCRIPTION TRI-BUILT Granular Underlayment A self-adhered underlayment used as an alternative to ASTM D 226, Type II roofing felt. The underlayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is suppli ed with a nominal thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. See manufacturer’s installation instructions for further detail. A CREEK Technical Services, LLC OCR20001 FL34539 Page 2 of 3 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. BEACON SALES ACQUISITIONS, INC. c/o OWENS CORNING ROOFING AND ASPHALT LLC TRI-BUILT Granular Underlayment APPLICATION Roof Deck: The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8” gap at abutting joints. Min. slope: 2:12 or in accordance in with FBC Application: Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment installation shall comply with FBC Table 1507.1.1.1. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave fold the underlayment away from eave onto itself. The underlayment shall be installed direct-to-decking with the lower release backer removed and pressed firmly into place to ensure complete contact with the deck. Repeat with upper release backer. Overlap successive courses with minimum 3” side laps and minimum 6” staggered end laps. In steep-slope applications (>6:12), it is permissible to nail the underlayment 12- inches on-center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). For valley applications, the roll shall be applied centered along the valley prior to installing the underlayment at the eave and overlapped a minimum of 6 -inches. For eave protection, the underlayment should extend to a point 18-inches beyond the interior wall. Min. Application Temperature: 40°F; Contact the manufacturer when installing at temperatures below the minimum application temperature. Allowable roof coverings: Mechanical attachment of asphalt shingles and slate shingles shall be permitted in accordance with the FBC. A CREEK Technical Services, LLC OCR20001 FL34539 Page 3 of 3 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. BEACON SALES ACQUISITIONS, INC. c/o OWENS CORNING ROOFING AND ASPHALT LLC TRI-BUILT Granular Underlayment LIMITATIONS 1)This evaluation report is not for use in the HVHZ. 2)Fire Classification is not within the scope of this evaluation. 3)Wind uplift resistance in not within scope of this evaluation. 4)Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer’s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5)Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6)The underlayment may be used as described in other current FBC product approval documents. 7)Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 8)The underlayment shall not be installed over existing roof coverings. 9)The underlayment shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. The first layer shall cover the entire bottom edge of the deck. End laps shall be staggered a minimum of 24-inches from the preceding course. 10)The underlayment shall be exposed on the roof deck for a maximum duration of 30 days. 11)All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT 2020.10.14 15:45:22 -04'00'