OFFICE OF THE FL# FL30310-R1
SFCRETARY
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer IKO Industries Ltd
Address/Phone/Email 40 Hansen Road South
Brampton, NON-US L6W 3H4
(905)457-2880 Ext4581
william.liu@iko.com
Authorized Signature William Liu
william.liu@iko.com
Technical Representative William Liu
Address/Phone/Email 40
Hansen Road South
Brampton, FL L6W 3H4
(416) 525-3740
william.liu@iko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 12/31/2024
Validated By Steven M. Urich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL30310 R1 COI IKO19002.2 2020 FBC Eval
Shin gles final.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D 3018 1990
ASTM D 3161 2016
ASTM D 3462 2010
ASTM E 108 2016
TAS 100 1995
TAS 107 2020
Equivalence of Product Standards
Certified By
www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvH%2bffZfjpUCSn6k7l pZ96MbxnNUZe3Q76B4ygcSbcE8w%3d%3d 1/2
1/20/2021 Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/16/2019
Date Validated 10/23/2020
Date Pending FBC Approval 10/28/2020
Date Approved 12/16/2020
Summary of Products
FL# Model,Number or Name Description
30310.1 IKO Shingles ASTM D 3161,Class F asphalt shingles, hip and ridge shingles,
starter strip&shingle strip
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL30310 R1 II IKO19002.2 2020 FBC Eval Shingles final.pdf
Approved for use outside HVHZ:Yes Verified By: Zachary R. Priest PE-74021
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See evaluation report for limits of use. FL30310 R1 AE IKO19002.2 2020 FBC Eva[Shingles final.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
0 U Kid 0
Credit Card
Safe
www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvH%2bffZfjpUCSn6k7l pZ96MbxnNUZe3Q76B4ygcSbcE8w%3d%3d 2/2
CREEK Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, L.L.0 (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,7T"EDITION (2020)
Manufacturer: IKO INDUSTRIES, LTD Issued October 22, 2020
40 Hansen Rd S
Brampton, ON L6W 3H4
Canada
(905)457-2880
www.iko.com
Manufacturing Plants: Calgary, Alberta
Hawkesbury, Ontario
Hillsboro,TX
Kankakee, IL
Sumas,WA
Sylacauga,AL
Toronto, Ontario
Wilmington, DE
Quality Assurance: PRI Construction Materials Technologies(QUA9110)
SCOPE
Category: Roofing
Subcategory: Asphalt Shingles
Code Edition: Florida Building Code, 7th Edition (2020)including High-Velocity Hurricane Zones(HVHZ)
Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.5.1, 1523.6.5.1
Properties: Physical properties,Wind Resistance,Wind Driven Rain
REFERENCES
Entity Report No. Standard Year
FM Approvals(TST1867) 3036971 FM 4475 2010
FM Approvals(TST1867) 3040947 FM 4475 2010
ASTM E 108 2016
FM Approvals(TST1867) 3041689 FM 4475 2010
FM Approvals(TST1867) 3044376 FM 4475 2010
FM Approvals(TST1867) 3045254 FM 4475 2010
FM Approvals(TST1867) 3046191 FM 4475 2010
PRI Construction Materials Technologies(TST5878) IKO-050-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-051-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-053-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-067-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-071-02-01 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) IKO-072-02-02 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-076-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-077-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-088-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-095-02-01 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) IKO-096-02-01 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) IKO-099-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-100-02-01 TAS 107 2020
PRI Construction Materials Technologies(TST5878) I KO-114-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) I KO-115-02-01 ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) I KO-117-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-120-02-01 ASTM D 3462 2010A
IK019002.2 FL30310-R2 Page 1 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK IKO IN LTD
Asphaltsphalt Shingles
TECHNICAL SERVICES, LLC
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST5878) IKO-121-02-01 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) IKO-123-02-01 ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) IKO-125-02-01 TAS 107 2020
ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) IKO-126-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-127-02-01 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) IKO-128-02-01 TAS 107 2020
ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) IKO-129-02-01 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) IKO-130-02-01 ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) IKO-131-02-01 TAS 107 2020
ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) IKO-140-02-01 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) IKO-148-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-153-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-171-02-01 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) IKO-171-02-02 TAS 107 2020
ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) IKO-171-02-03 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-198-02-01 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) IKO-198-02-02 TAS 100 2020
PRI Construction Materials Technologies(TST5878) IKO-198-02-03 ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) IKO-199-02-01 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) IKO-199-02-02 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-199-02-03 ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) IKO-201-02-01 ASTM D 3462 2010A
ASTM E 108 2016
ASTM D 3018 1990(R94)E1
PRI Construction Materials Technologies(TST5878) IKO-201-02-02 ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) IKO-201-02-07 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-202-02-01 ASTM D 3462 2010A
ASTM E 108 2011
ASTM D 3018 1990(R94)E1
PRI Construction Materials Technologies(TST5878) IKO-202-02-02 TAS 107 2020
ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) IKO-202-02-07 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-203-02-01 ASTM D 3462 2010A
ASTM E 108 2011
ASTM D 3018 1990(R94)E1
PRI Construction Materials Technologies(TST5878) IKO-203-02-02 ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) IKO-203-02-07 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-205-02-01 ASTM D 3462 2010A
ASTM E 108 2016
ASTM D 3018 1990(R94)E1
PRI Construction Materials Technologies(TST5878) IKO-205-02-02 ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) IKO-205-02-07 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-206-02-01 ASTM D 3462 2010A
ASTM E 108 2016
ASTM D 3018 1990(R94)E1
PRI Construction Materials Technologies(TST5878) IKO-206-02-02 ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) IKO-206-02-07 TAS 100 1995
PRI Construction Materials Technologies(TST5878) IKO-208-02-01 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) IKO-217-02-01 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) IKO-218-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) 476C0017.1 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) 476C0017.2 ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) 476C0017.3 ASTM E 108 2016
PRI Construction Materials Technologies(TST5878) 476C0020.1 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) 476C0020.2 ASTM D 3161 2016
IKO19002.2 FL30310-R2 Page 2 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK IKO IN LTD
Asphaltsphalt Shingles
TECHNICAL SERVICES, LLC
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST5878) 476C0020.3 ASTM E 108 2016
PRI Construction Materials Technologies(TST5878) 476C0033.1 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) 476C0033.2 ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) 476C0033.3 ASTM E 108 2016
PRI Construction Materials Technologies(TST5878) 476T0O02 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) 476T0O03 TAS 100 1995
PRI Construction Materials Technologies(TST5878) 476T0O04 ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) 476T0O12 ASTM D 3462 2010A
ASTM D 3018 1990(R94)E1
PRI Construction Materials Technologies(TST5878) 476T0O13 ASTM D 3161 2016
TAS 107 2020
PRI Construction Materials Technologies(TST5878) 476T0O21 ASTM D 3462 2010A
ASTM D 3018 1990(R94)E1
PRI Construction Materials Technologies(TST5878) 476T0022 ASTM D 3161 2016
TAS 107 2020
PRI Construction Materials Technologies(TST5878) 476T0O23 ASTM E 108 2016
PRI Construction Materials Technologies(TST5878) 476T0O34 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) 476T0O39 ASTM D 3462 2010A
ASTM D 3018 1990(R94)E1
PRI Construction Materials Technologies(TST5878) 476T0O40 ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) 476T0O41 TAS 100 1995
PRI Construction Materials Technologies(TST5878) 476T0O42 ASTM D 3462 2010A
ASTM D 3018 1990(R94)E1
PRI Construction Materials Technologies(TST5878) 476T0O43 TAS 100 1995
PRI Construction Materials Technologies(TST5878) 476T0O44 ASTM D 3462 2010A
ASTM D 3018 1990(R94)E1
PRI Construction Materials Technologies(TST5878) 476T0045 ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) 476T0O46 TAS 100 1995
PRI Construction Materials Technologies(TST5878) 476T0O57 ASTM D 3462 2010A
PRI Construction Materials Technologies(TST5878) 476T0O58 ASTM E 108 2016
PRI Construction Materials Technologies(TST5878) 476T0O59 ASTM D 3161 2016
PRI Construction Materials Technologies(TST5878) 476T0O61 ASTM D 7158 2019ael
PRODUCT DESCRIPTION
RoofshakeTm HW 13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Sumas) architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Shingles shall be used in the non-HVHZ only.
ArmourshakeTM 18-1/2" x 37-3/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Sumas) architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Royal Estate TM 13-1/4" x 40", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Toronto) architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Crowne Slate 13-1/4" x 39-1/2", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Toronto) architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Shingles shall be used in the non-HVHZ only.
Dynasty TM 13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Calgary, Hawkesbury, architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Hillsboro, Kankakee& Shingles manufactured in Calgary and Sumas shall be used in the non-HVHZ only.
Sumas)
NordiCTM 13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Hillsboro&Kankakee) architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
IKO19002.2 FL30310-R2 Page 3 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK IKO IN LTD
Asphaltsphalt Shingles
TECHNICAL SERVICES, LLC
Cambridge TM 13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Calgary, Hawkesbury, architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Hillsboro, Kankakee, Shingles manufactured in Calgary and Toronto shall be used in the non-HVHZ only.
Sumas, Sylacauga,
Toronto&Wilmington)
CRC Biltmore® 13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Calgary, Hawkesbury, architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Sumas& Toronto) Shingles manufactured in Calgary and Toronto shall be used in the non-HVHZ only.
CRC Regency® 13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Calgary& Hawkesbury) architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Shingles manufactured in Calgary shall be used in the non-HVHZ only.
CRC Superglass® 13-1/4" x 39-3/8", ASTM D 3161, Class F self-sealing, 3-tab asphalt shingle with
(Calgary, Hawkesbury& fiberglass mat coated on both sides with asphalt and surfaced with granules complying
Toronto) with ASTM D 3462. Shingles manufactured in Calgary and Toronto shall be used in the
non-HVHZ only.
MarathonT" Plus AR 13-1/4" x 39-3/8", ASTM D 3161, Class F self-sealing, 3-tab asphalt shingle with
(Calgary, Hawkesbury, fiberglass mat coated on both sides with asphalt and surfaced with granules complying
Hillsboro, Kankakee, with ASTM D 3462. Shingles manufactured in Calgary, Sumas and Toronto shall be
Sumas, Sylacauga& used in the non-HVHZ only.
Toronto)
Hip&Ridge " 12 13-1/4" x 36", ASTM D 3161, Class F fiberglass reinforced, monolayer asphalt hip and
(Kankakee&Sylacauga) ridge shingle surfaced with granules and perforated every 12-inches complying with
ASTM D 3462.
Hip&Ridge PIusTM 13414: x 39-3/8", ASTM D 3161, Class F fiberglass reinforced, monolayer asphalt hip
(Calgary) and ridge shingle surfaced with granules and perforated every 13-inches complying with
ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Hip and Ridge TM 13-1/4" x 39-3/8", ASTM D 3161, Class F fiberglass reinforced, monolayer asphalt hip
(Sumas) and ridge shingle surfaced with granules and perforated every 10-inches complying with
ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Armour Starter TM 13-1/4" x 39-3/8", ASTM D 3161, Class F fiberglass reinforced asphalt strip embedded
(Sumas) with granules complying with ASTM D 3462. For use with ArmourshakeTM shingles.
Leading Edge PIusTM 7-7/8" x 40-7/8", ASTM D 3161, Class F fiberglass reinforced, monolayer asphalt
(Hawkesbury) shingle strip surfaced with granules complying with ASTM D 3462.
IKO19002.2 FL30310-R2 Page 4 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK IKO IN LTD
Asphaltsphalt Shingles
TECHNICAL SERVICES, LLC
INSTALLATION
......................................................................................................................................................................................................................................................................................................................................................................................
RoofshakeT"' HW [..._Basic Wind...S.peed....(V I?)..............Max,....1.94..!p.P...h..................................................................................................................................................................................................
(Sumas) Basic Wind Speed....(Vasd.)..........._Max.....150 mph......................................................................................................................................................................................................................
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
...................................................................................................................:.............................................................................................................................................................................................................................................................
Deck(Non-HVHZ): Solidly sheathed in accordance with FBC requirements.
.......................................................................................... ........ ......... ......... ......... ......... .....
..._Underlayment:.......................................................I.n..accordance with...FBC...requirements...............................................................................................
Min. slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
....... ......... ......... .. ......... .........
Installation (Non-HVHZ): Installed with 5-7/8 inch exposure, in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using "4 Nail
Pattern"detailed below.
Nail Line Common Bond
Standard Application
Pequires4 Nails
7/8
- - - - - - - - - - - - - Nail •
Line
5-7/8
Figure 1. RoofshakeTm HW
4 Nail Pattern (Non-HVHZ only)
...................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
IKO19002.2 FL30310-R2 Page 5 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK IKO INDUSTRIES, LTD
Asphalt Shingles
TECHNICAL SERVICES, L,L,C
ArmourshakeTM Basic Wind Speed...(Vult)..............Max. 194 mph..................................................................................................................................................................................................
..................................
(Sumas) ..._Basic Wind Speed...(Vasd)............Max. 150 mph.................................................................................................................................................................................................
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
1...................................................................................................................:..............................................................................................................................................................................................................................................................._.
Deck(Non-HVHZ): Solidly sheathed in accordance with FBC requirements.
........................................................................................ .. ........ ......... .........
..._Underlayment:......................................................I.n..accordance with FBC requirements....................................................... ... ..................
Min. slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
......... ......... .. ......... ......... ......... ......:
Installation (HVHZ): Installed with 5-7/8 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
..........................................................
Installation (Non-HVHZ): Installed with 5-7/8 inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"5 Nail
Pattern"or"6 Nail Pattern"detailed below.
........................................................................................................................._..................................................................................................................._..................................................................................................................................................................................................................................................................
Standard Application
Requires 5 Nails/Fasteners
Nail Line
Alignment
Notches
Figure 2. ArmourshakeTM
5 Nail Pattern (Non-HVHZ only)
Nailing-Steep Slopes/High Wind Areas Applications
Requires 6 Nails/Fasteners
Nail Line
Alignment Alignment
Notches ' F Notches
Figure 3. ArmourshakeTM
6 Nail Pattern
IKO19002.2 FL30310-R2 Page 6 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK IKO INDUSTRIES, LTD
Asphalt Shingles
TECHNICAL SERVICES, L,L,C
RoyalEstate TM Basic Wind Speed...(Vult)..............Max, 194 mph..................................................................................................................................................................................................
.................................
(Toronto) ..._Basic Wind Speed...(Vasd)............Max. 150 mph.................................................................................................................................................................................................
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
1...................................................................................................................:..............................................................................................................................................................................................................................................................._I
Deck(Non-HVHZ): Solidly sheathed in accordance with FBC requirements.
......................................................................................... ... ......... ......... ......... ......... .......
..._Underlayment:......................................................I.n..accordance with FBC requirements...............................................................................................
Min. slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
... ......... ......... ......... .........
Installation (HVHZ): Installed with 5-7/8 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
...................................................................................................................:.................................................................................................................................................................................................................................................................
Installation (Non-HVHZ): Installed with 5-7/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
........................................................................................................................._..................................................................................................................._..................................................................................................................................................................................................................................................................
Standard Application
Requires 4 Nails/Fasteners
r - - - - - - - - --------- ------ i
JA I
Y F
7777
Nails
Figure 4. Royal Estate"
4 Nail Pattern non-HVHZ only)..............................................................................................................................................................................
Steep Slope/High Wind Applications
Requires6 Nails/Fasteners
T. +[-
Nails
Figure 5. Royal EstateTM
6 Nail Pattern
...................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
IKO19002.2 FL30310-R2 Page 7 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK IKO INDUSTRIES, LTD
Asphalt Shingles
TECHNICAL SERVICES, LLC
Crowne Slate Basic Wind S eed V Max. 194 mph
............................................................P...................(....._�It)............:......................................................P.......................................................................................................................................................................................................
(Toronto) ..._Basic Wind Speed...(Vasd)............Max. 150 mph.................................................................................................................................................................................................
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
I...................................................................................................................:..............................................................................................................................................................................................................................................................._
Deck(Non-HVHZ): Solidly sheathed in accordance with FBC requirements.
......................................................................................... ... ......... ......... ......... ....... .......
..._Underlayment:......................................................I.n..accordance with FBC requirements...............................................................................................
Min. slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
..... ......... ......... ......... .........
Installation (Non-HVHZ): Installed with 5-7/8 inch exposure, in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using "5 Nail
Pattern"detailed below.
Nail Line
10" EXPOSURE
ti
Standard Application
Requires 5 Nails/Fasteners *�
10"
I Nail Line
1
I
I
Figure 6. Crown Slate
5 Nail Pattern (Non-HVHZ only)
...................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
IK019002.2 FL30310-R2 Page 8 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK IKO INDUSTRIES, LTD
Asphalt Shingles
TECHNICAL SERVICES, L,L,C
DynastyTM
...Basic Wind Speed )...(V�l? ..............Max. 194 mph..................................................................................................................................................................................................
(Calgary(Non-HVHZ), ..._Basic Wind Speed...(Vasd)............Max. 150 mph...................................................................................................................................................................................................................................
Hawkesbury, Kankakee& Deck(HVHZ): In accordance with FBC requirements;
Sumas (Non HVHZ)) Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
and construction.
I...................................................................................................................:..............................................................................................................................................................................................................................................................._
Deck(Non-HVHZ): Solidly sheathed in accordance with FBC requirements.
.......................................................................................... ... .... .... .... ........
Nord
icTM Underla ment In accordance with FBC requirements.
.....................................y................................................... ....
(Kankakee) : Min. slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
and shin les at slopes greater than 21:12. .
... ....................9......................................p.............9..........................................................................................................................................................................i
Installation (HVHZ): Installed with 5-7/8 in. exposure in accordance with RAS
CRC Regency® 115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
...................................................................................................................:.................................................................................................................................................................................................................................................................
Installation (Non-HVHZ): Installed with 5-7/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either'A Nail
Pattern"or"6 Nail Pattern"detailed below.
........................................................................................................................._..................................................................................................................._..................................................................................................................................................................................................................................................................
MJ4• ArmourZone
ArmourZone
Standard Application `
Requires 4 Nails/Fasteners
Common Bond
-----------------------------------------------
"IrmtrmourZone
1/4
17 r7
Figure 7. DynastyTm and NordicT""
4 Nail Pattern (non-HVHZ only)
..............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................._
1 1/4•
1.1�4• ArmourZone
ArmourZone
Steep Slope/High Wind Applications
Requires6 NaiIs/Fasteners
Common Bond
- ---------
-----------
-- ---------- - ----------- -----------
- ----------- ------------ -----------
1-1/4"
ArmourZone
Figure 8. DynastyTm and NordicT""
6 Nail Pattern
...................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
IKO19002.2 FL30310-R2 Page 9 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK IKO INDUSTRIES, LTD
Asphalt Shingles
TECHNICAL SERVICES, LLC
Cambridge TM
...Basic Wind Speed...(V�.?)..............Max. 194 mph..................................................................................................................................................................................................
(Calgary(Non-HVHZ), ..._Basic Wind Speed...(Vasd)............Max. 150 mph...................................................................................................................................................................................................................................
Hawkesbury, Hillsboro, Deck(HVHZ): In accordance with FBC requirements;
Kankakee, Sumas, Solidly sheathed min. 19/32 in. plywood or wood plank for
Sylacauga, Toronto(Non- l new construction; Min. 15/32 in. plywood existing
HVHZ)&Wilmington) construction.
€...................................................................................................................:.................................................................................................................................................................................................................................................................
Deck(Non-HVHZ): Solidly sheathed in accordance with FBC requirements.
......................................................................................... ... .... ................. ....
and Underlayment: In accordance with FBC requirements.
....
Min. slope: 2:12 and in accordance with FBC requirements. Refer to
CRC BiltmoreTM the manufacturer's application instructions when installing
(Calgary(Non-HVHZ),
shing�es at slopes than21:12.. . e ._ .__._ ...............................................................................................
Hawkesbur , Kankakee,
Y Installation (HVHZ): Installed with 5-7/8 in. exposure in accordance with RAS
Sumas(Non-HVHZ)& 115 and manufacturer's published installation instructions.
Toronto(Non-HVHZ)) Shingles shall be attached using "6 Nail Pattern" detailed
below.
...................................................................................................................:.................................................................................................................................................................................................................................................................
Installation (Non-HVHZ): Installed with 5-7/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either'A Nail
Pattern"or"6 Nail Pattern"detailed below.
Nail Line Common Bond
Standard Application til
Requires 4 Nails/Fasteners
1
- - - - - - - - - - - - - - Nail . �
Line
5-7/8
Figure 9. Cambridge" and CRC BiltmoreTM
4 Nail Pattern (non-HVHZ only)
.........................
Nail Line Common Bond
Steep Slope/High Wind Applications
Requires 6 Nails/Fasteners
7/8"
L
s - - - - - - - - - - - - Nail
Line
5-7/8
Figure 10. CambridgeTM and CRC BiltmoreTM
6 Nail Pattern
L j
IKO19002.2 FL30310-R2 Page 10 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK IKO INDUSTRIES, LTD
Asphaltsphalt Shingles
TECHNICAL SERVICES, L,L,C
CRCSuperglassTM Basic Wind Speed...(V�I?)...............Max, 194 mph..................................................................................................................................................................................................
.................................
(Calgary(Non-HVHZ), ..._Basic Wind Speed...(Vasd)............Max. 150 mph...................................................................................................................................................................................................................................
Hawkesbury, &Toronto Deck(HVHZ): In accordance with FBC requirements;
(Non-HVHZ)) Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
and construction.
.1..................................................................................................................:.................................................................................................................................................................................................................................................................
Deck(Non-HVHZ): Solidly sheathed in accordance with FBC requirements.
MarathonTM Plus AR ......................................................................................... ... .... .... ....
Underlayment: In accordance with FBC requirements.
Non-HVHZ
(Calgary( ), Min. slope: 2:12 and in accordance with FBC requirements. Refer to
Hawkesbury, Hillsboro, the manufacturer's application instructions when installing
Kankakee, Sumas Non-
( shingles at slopes greater than 21:12. .
HVHZ , Sylacauga& (_...... )......... .........
Installation HVHZ : Installed with 5-7/8 in. exposure in accordance with RAS
Toronto(Non-HVHZ)) 115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
and below.
...................................................................................................................:.................................................................................................................................................................................................................................................................
Installation (Non-HVHZ): Installed with 5-7/8 in. exposure in accordance with FBC
MarathonTM requirements and manufacturer's published installation
(Hillsboro&Sylacauga) instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
Standard Application
Requires 4 Nails/Fasteners
Sealant Strip
Figure 11. CRC Superglass TM, MarathonTM Plus AR and MarathonTM
4 Nail Pattern (non-HVHZ only)
Steep Slope/High Wind Applications
Requires 6 Nails/Fasteners
Sealant Strip
Figure 12. CRC Superglass TM, MarathonTM Plus AR and MarathonTM
6 Nail Pattern
...................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
IKO19002.2 FL30310-R2 Page 11 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK IKO INDUSTRIES, LTD
Asphalt Shingles
TECHNICAL SERVICES, LLC
Hip&Ridge TM 12 Basic Wind Speed...(V�i?)..............Max, 194 mph..................................................................................................................................................................................................
.................................
(Kankakee&Sylacauga) Basic Wind Speed...(Vasd)............Max. 150 mph..................................................................................................................................................................................................
..................................
Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed
and min. 19/32 in. plywood or wood plank for new construction;
Min. 15/32 in. plywood existing construction..
Hip& Ridge PIusTM Deck(Non-HVHZ): Solidly sheathed in accordance with FBC requirements.
(Calgary) ` Underla ment: In accordance with FBC requirements.
non-HVHZ only) ......................................y.........................................................................:.................................................................................................................9........................................................................................................................................
y) . Min. slope:......................................................................2.�.2...and in with...FBC...requirements..................... ....... ..................................
Installation: Installed with 5-5/8 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
revailin wind.
...............................................................................................................................................p...............................g.....................................................................................................................................................................................................................
Perforation Marks
Start Direction pravailling wind
hem-
Ell
l
5
Nails
1 1
PO
1
1 �
• 1
1 1
1 �1 T Taper Cut
6-1/4"
1
Figure 13. Hip & RidgeTM 12 and
Hip& Rid 9 a PIusTM non-HVHZ only)
IKO19002.2 FL30310-R2 Page 12 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK IKO INDUSTRIES, LTD
Asphalt Shingles
TECHNICAL SERVICES, L,L,C
Hipand Ridge TM Basic Wind Speed...(Vult)..............Max, 194 mph..................................................................................................................................................................................................
.................................
(Sumas) ..._Basic Wind Speed...(Vasd)............Max. 150 mph.................................................................................................................................................................................................
Deck(Non-HVHZ): Solidly sheathed in accordance with FBC requirements.
... ......... ......... ......... ....... ........
Underlayment:......................................................I_n accordance with F_BC requirements...............................................................................................
Min slope 2 12 and in accordance with FBC requirements.
...... ......... ......... ......... ......... ........ .........
Installation: Installed with 5-5/8 inch exposure, in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailin wind.
..........................................................................................................................................................................................................................................._........................................9......................................................................................................................................................................................
Nails
I �
startDirection of gravelling wind
here _ -��` -- •
� I
1"Taper Cut
I
Perforation Marks 1" Optional Taper Cut
I I I I I I
I I 1 I { I
I I 1 I { I
I { {
i
Figure 14. Hip and RidgeTM (non-HVHZ only)
IKO19002.2 FL30310-R2 Page 13 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK IKO INDUSTRIES, LTD
Asphalt Shingles
TECHNICAL SERVICES, LLC
ArmourStarter TM Basic Wind Speed...(V�Is)..............Max, 194 mph..................................................................................................................................................................................................
.................................
(Sumas) ..._Basic Wind Speed...(Vasd)............Max. 150 mph.................................................................................................................................................................................................
Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed
min. 19/32 in. plywood or wood plank for new construction;
Min. 15/32 in. plywood existing
....... ......... ......... construction.
Deck(Non-HVHZ): Solidly sheathed in accordance with FBC requirements.
........................................................................................ ........ ......... ......... .......
..._Underlayment:......................................................I.�..accordance with FBC requirements...............................................................................................
Min slope 2 12 and in accordance with FBC requirements.
..... ........ .........
Installation: Installed in accordance with the FBC and manufacturer's
published installation instructions. Shall be attached with
min. 1"x 12 a. roofing nails with min.3/8-inch head.
...................................................................................................................................................................................................................................................................................................... ................................... ............................................................................................................................................................
Standard Application Requires 4 Fails/Fasteners
Match Color
STARTER COURSE to Selected
1" and 13" from Each End Armourshake
Shingle
Figure 15.Armour Starter"
...................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
LeadingEdge PlusTM ..._Basic Wind Speed...(V �t)..............Max. 194._m.P...h..................................................................................................................................................................................................
(Hawkesbury) Basic Wind Speed...(Vasd)............Max.....1.50..mph.....................................................................................................................................................................................................................
Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed
min. 19/32 in. plywood or wood plank for new construction;
......,.
Min. 15/32 in. plywood existing construction.
Deck(Non-HVHZ): Solidly sheathed in accordance with FBC requirements.
......................................................................................... .. ......... ......... ......... ....... ..........................................................
..._Underlayment:......................................................I.n..accordance with...FBC requirements...............................................................................................
Min. slope: 2:12 and in accordance with FBC requirements.
Installation: Installed in accordance with the FBC and manufacturer's
published installation instructions. Shall be attached with
min. 1"x 12..9 a. roofing nails with min.3/8-inch head.
................................................................................................................................................................................................... .................................. ...........................................................................................................................................................
Standard ApPlleaticin
Requires 4 Nails/Fasteners 1'from Each End •
3'to 4"from Bottom
Figure 16. Leading Edge PIusTM
...................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
IKO19002.2 FL30310-R2 Page 14 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK IKO IN LTD
Asphaltsphalt Shingles
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
5) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
6) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
7) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7th Edition (2020) including High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents
submitted by the named manufacturer.
"""''1- 2020.10.22
p
R. ��i
.� 9
No 74021 •
ognanr•z•a by z.hn a.v
-04'00'
STATE OF
'o 0,�•,.Ac P ,�� Zachary R. Priest, P.E.
'����` •� O R \� N.•'� ��� Florida Registration No. 74021
SS;�NA ��`��� Organization No.ANE11669
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
IK019002.2 FL30310-R2 Page 15 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.