HomeMy WebLinkAboutAPPROVED ES 1500
SOLARBAN 70XL
3/16" Gray
0.09 sgp
3/16" Clear
SOLARBAN 70XL Surface 3
Visible transmittance %
Exterior visible reflectance %
Interior visible reflectance %
Solar exterior reflectance %
Solar transmittance %
Shading coefficient (sc)
The results represent Center-of-Glass performance data based on NFRC 100 Environmental Design Conditions utilizing the LBNL Window 7.3 software program.
Performance data is based on representative samples of factory production. Actual values may vary slightly due to variations in the production process. This data
is to be used for comparison purposes and should not be considered a contract. It is the recipient's responsibility to entire the manufacturability of the above
glazing con-gurations as well as evaluating appropriate design considerations such as wind and snow load analysis, thermal stress analysis, and local building
code compliance. Tecnoglass recommends that a full size mock-up be reviewed under the speci-c job-site conditions and retain the mock-up as a basis of
acceptable product.
Configuration
Gray,3/16"
0.09 sgp
Clear,3/16"
SOLARBAN
70XL
Performance
33
8
13
15
13
0.42
Solar heat gain coefficient (shgc)
U-Value (Winter W/m2*k)
U-Value (Summer W/m2*k)
U-Value (Winter BTU/h*ft2*f)
U-Value (Summer BTU/h*ft2*f)
Light to Solar Gain (LSG)
0.37
5.35
4.85
0.94
0.85
0.89
Tecnoglass Inc.www.tecnoglass.com
Note: Be aware that laminated glazing constructions may have increased optical distortion and/or strain iridescence from stacked multiple individual layers
especially when the glass lites are heat treated. In addition transmitted and re9ective color differences can occur when a low-e or re9ective coating is located
adjacent to the interlayer material. A coating facing an airspace in an IG unit may appear a different color than the same coating in a laminate.