HomeMy WebLinkAboutPROJECT INFORMAATIONt1 t 11 2 zI W < 6 3 V 0 aa..aJa REPAIR OF TOWNHOUSE 2801 N. HIGHWAY A1A. APT - HUTCHINSON ISLAND, FL 34949 FileCOPy FOR STEVEN & GINA A. BEXLEY ,gp#"EO'011-ICE 1146 WINTER GREEN ST, CODE COMPLIANCE LAKE PLACID, FL 33852 ST. lLUCIE COUNTY +R��0CC clu/2z PROJECT DESCRIPTION: REPAIR EXTERIOR WALL OF TOWNHOUSE FOR SECOND FLOOR, REPLACE WINDOW, REPLACE DAMAGED STUDS, SHEATHING, AND STUCCO FINISH; AND REPLACE DAMAGED FLOOR JOIST, SUB FLOOR AND FLOORING. Certification for Desian Load Compliance 1. Design Code: Florida Residential code 2020 7th Edition using ASCE 7-10 2. Structure Design is: X Enclosed_ Partialty Enclosed_ Open Building 3. Risk Category: _I X II _III _IV Exposure Category _B __X LC _D Adjustment coefficient 11_21 4. Design Wind Velocity 165 mph _ASD _LRFD End Zone Width 336" ft. S. Mean Roof Height: Existing ft. Roof Pitch: Existing:12 Parapet: _ft. 6. Components & Cladding Design Pressure used: (PSF, based on Actual sq. ft. @ 30' MRH (Worst Case) Zone 1: N/A Zone 2: N/A Zone 3: N A Zone 4: 61.7 Zone 5: -74.1 Garage: NIA 7, Design Loads: Floor Exist PSF Roof/Dead: Exist PSF Roof/Live: Exist PSF Balcony: _PSF Dock: _PSF Deck: _PSF Stairs: _PSF Fence: _PSF Railings: _PSF B. Were Shear Walls Considered for Structure? —Yes X No Not applicable Explain Why Not: Existing 9. Is a Continuous Load Path Provided? Yes Not Applicable Explain Why 10. Design Soil Bearing Pressure: N/A PSF Soil boring Test required: _Yes X No(based upon section 1803.2 exception) PRODUCT REVIEW PRODUCT OPENING DESIGN PRODUCT MANUFACTURER MODEL # APPROVALS GLASS ATTACHMENT METHOD PRESSURES DESIGN TYPE (WORST CASE) PRESSURES WINDOW ZONE 4-56.5 +64.0/-80 PGT INDUSTRIES SH700 NOA# IMPACT %" ULTRACON @17-3/8"MAX. AND ZONE 5-64.5 With 16-0714.06 SOLAR ' 6-1/2" MAX. FROM EACH CORNER, Mullion HEAT WITH A 1-3/4" MIN. EMBEDMENT AND Tube GAIN 2-1/2" MIN. EDGE DISTANCE FBC107.1 0.53 THE SEAL HEREON IS PROVIDED ONLY TO INDICATE OUR REVIEW AND APPROVAL FOR USE OF PRODUCTS LISTED FOR THIS STRUCTURE. THE ACCEPTANCE OF THESE PRODUCTS AND METHODS OF ATTACHMENT ARE BASED ENTIRELY UPON TEST DATA PROVIDED BY THE MANUFACTURER, WHICH CARRIES ITS OWN ENGINEER'S CERTIFICATION AND IMPLIES NO WARRANTY OR GUARANTEE BY THIS ARCHITECT FOR THESE PRODUCTS. RICHAFD E. Drawing Title- Pro* No.- Drawing No.: AC17 S21-018 Wm+circaABeft COVER RCHRE ,tip. scale: NTS A 0• 1 tr�Daebw NOTES ue Date: Fat FMalRais! 1-10-22 S.R. North AM ��-----�®�� I WORK AREA I I WALL LINE OF WALL LEOOWF BELOW LINE OF WALL I I ui BELOW > ) J Z U) 0 U Z o 2801-H U 2801-1 LINE OF WALL 0 BELOW _ _ _ () 2801-J ROOF DECK LINE OF WALL BELOW ROOF OVER PATIO BELOW SITE PLAN ze LEGAL DESCRIPTION: CORAL COVE BEACH SECTION ONE--BLK 7N 16.66 FT OF S88.40 FT OF LOT 2 AND EAST 10 FT OF VAC ALLEY ADJ/ ON WEST (APT 2801-1). PUBLIC RECORDS OF ST LUCIE COUNTY, FLORIDA. N N W 2 PARKING SPACES ER UNIT. uQo 7Z Ld RICHARD E. Townhouse Drawing Tim: Prof. No: N o ATWOOD Rap& 21-018 o a o AFCHRECT Gin c�A Bexley ' of a a or I SCale NTS mo omawer ITDeeb � SITE PLAN saw Date rbn n.W004.O �m�o�s 1-10-22 Drawing No.- Al .1 N lal N nay J W RICHARD E. 3 a ATWOOD � N 0 o O Ar4Hff CT cat a a a. CiepNo Dedow momoca . FvlFA RUN 4m-aw-cm East Elevation (2) 3050 Second Floor Plan `j ITownhouee ste' �e ; + am a eery ti Existing Metal Roof Existing Gutter Existing Facia New Impact Energy Coated Windows New Stucco Existing Leader Existing Window To Remain Existing Door To Remain Approximate Finished Grade Existing 8" Block Existing Wood Studs New Impact Energy Coated Windows Drawing TiBe Froj. No: Drawing No.- 21-018 Scale NTS A 4.1 seue Date ELEVATION 1-6-22 N Cj N IIQ� c� th im oC3o aQa Note: Existing 2" x 4" wood studs @24"/o.c. with 5/8" CDX Plywood with 15# Felt and Paper Backed Wire Lath and 5/8" Brown Coat Stucco and %" Finish Coat and Paint. 5/8 CDX PLAYWOOD ! �AHEATHING, USE 8d. NAILS O.C. ADD 1 STUD TO EXISTING , 2 16-d @ 1 12" o.c. : i EXISTING TRUSS JOIST TO REMAIN T Existing Stud Wall EXISTING 2 x 4 STUD WALL @ 24" o.c. SIMPSON GA 1 STUD TO PLATE REMOVE DAMAGED TRUSS /JOIST FORM NEW MEMBERS 2-2X10 W PLYWOOD SPACER ADD 12X4 STUD TO EXISTING 2X4PLATE 2-16d NAILS SECTION THRU BEAM THRU BOTTO OF PLATE - ► 2X4STUD EGA 1 STUD TO PLATE -2X4PLATE 2 2 X 10 WITH %" PLYWOOD I; SPACER GLUED & NAILED V. A W/16d NAILS @ 8" o.c. STAGGERED BOTH SIDES 1 BEAM DETAIL RICHARD E. ATWOOD ARCHffECr ClrepWc DeeWm uC. M ao®®a Fv! PWM F184M y RepaIr Stem + Gina A Beft SIDE VIEW Second Floor East SIMPSON GA 1 STUD TO EX. 2 X 4 PLATES TWO STUDS @ BOTH SIDES 24" o.c. OFISTUDS NEW DBL 2 x 10 JOIST 16' LONG HGUS210-1 JOIST HANGER SECOND FLOOR ONLY STRAP STUDS TO EX. FRAMING BELOW WITH SIMPSON LSTA 12 W/14-10d NAILS CALCS: JOIST Ln = 16'22* = DL 40=LL M=3968'sq SM req =34.0' in cu A= 192/360 = .53 1 req=195.5"Sq DBL 2 x 10 = SM=48.8 in cu DBL 2 x10 = SM=48.8 in cu 1=232" sq Drawing Tft: DETAILS Prof. No: 21-018 Scallea NTS seas Date- 1-6-22 Drawing No.: A4.2 non NOTES: STUCCO ON RIBLATH OR PAPER BACK SHALL BE ATTACHED TO HORIZONTAL FRAMING AS PER AS71 M C-1063: LATH SHALL BE ATTACHED TO FRAMING MEMBERS WITH CORROSION RESISTANT MATERIALS. ATTACHMENTS SHALL BE SPACED NOT MORE THAN 5"O.C. ALONG SUPPORTS. FASTENERS TO BE USED CAN BE 6D COMMON OR ROOFING WAILS HAVING A MIN. V0 PENETRATION INTO HORIZONTAL FRAMI"lk;G MEMBERS OR STAPLES W/A MIN. 4" CROWN ENGAGED NOT LESS THAN (3) STRANDS OF LATH AND MUST PENETRATE THE WOOD FRAMING MEMBERS %" MIN. 2 X 4 STUDS AT 16" o/c STRAP EACH STUD WITH SIMPSON SP4 WITH 6- 10d X I Y2" NAILS 2 4" PLATE ANCHORED WITH 3/8 X5 LAG BOLTS 924" o.c. MAX FOR SECOND FLOOR. RICHARD E, ATWOOD ARCHMECT GrapW Daslgw umomoosw Fat ft Fl MW STRAP STUD TO EX. FRAMING & LINTEL ABOVE WITH SIMPSON LSTA 12 W/14-10d NAILS X HE4ER 2 X 6 W1 YVI PLYWOOD SPACER GLUED & NAILEDW/16d NAILS @ -P 8" o.c. STAGGERED BOTH 2" X 4" STUDS + Gina A, Beft NAIL NEW HEADER STUD TOGETHER W/16D NAILS @8"O.C. STAG AlINDOW 3PENING SIMPSON GA-1 STUD TO —PLATE -STRAP STUD TO EX. FRAMING BELOW WITH SIMPSON LSTA 12 W/14- 10d NAILS Drawing TdJe, lPr4 No: AW-111167i 1 21-018 18cale- NTS Date: 1-6-22 Drawing No.: A4.3