HomeMy WebLinkAboutAPPROVED, 13406 HARBOUR RIDGE BLVD -12.22.21-A-1WALL PLAN LEGEND 1. ALL WORK BY ALL TRADES TO BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE, LOCAL, & GOVERNMENTAL CODES, ORDINANCES, STANDARDS AND RESTRICTIONS. 2. ALL TRADES TO COORDINATE THEIR WORK WITH ALL OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 3. CONTRACTOR TO VERIFY ALL DIMENSIONS ON THE JOB PRIOR TO COMMENCING CONSTRUCTION AND NOTIFY ARCHITECT OF ALL DISCREPANCIES. DIMENSIONS ALWAYS TAKE PRECEDENCE OVER SCALED DRAWINGS. 4. ALL DIMENSIONS ARE NOMINAL TO THE FACE OF STUDS, CONC. BLK. OR EDGE OF MONOLITHIC SLAB FOOTING UNLESS NOTED OTHERWISE. DOOR AND WINDOW SIZE OPENINGS TO BE VERIFIED WITH THE MANUFACTURER. 5. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION, THE CONTRACTOR IS EXPECTED TO FURNISH & INSTALL ALL ITEMS FOR COMPLETE FULLY OPERATIVE SYSTEMS IN FIRST CLASS WORKMANLIKE MANNER. 6. INSULATE EXTERIOR MASONARY WALL WITH MIN. R-5.0 INSUL., EXTERIOR WD. FRAMED WALLS WITH R-19 INSUL. AND ATTIC SPACES WITH MIN. R-30 INSUL. 7. COMPACT ALL FILL TO A MIN. OF 95% DENSITY AND POISON SOIL FOR TERMITES; MIN. SOIL BRG.: 2500 P.S.F. 8. MIN. CONC. STRENGTH: 3000 P.S.I. @ 28 DAYS. MIN. CONCRETE COVERAGE FOR REINF. BARS. SLAB: 3/4"; BEAMS & COLS: 1 1/2"; TIE COLS: 3/4"; FORMED CONC. BELOW GRADE: 2" & UNFORMED CONC.: 3". 9. REINFORCING STEEL TO BE GRADE 60. 10. DETAILS OF CONCRETE REINF. SHALL BE IN ACCORDANCE WITH "THE MANUAL OF STD. PRACTICE FOR REINFORCED CONCRETE CONSTRUTION". TRAP. 11. TIE COLUMNS TO HAVE DOWELS INTO CONCRETE FTG. WITH THE SAME SIZE AND NUMBER OF DOWELS AS VERTICAL REINF. BARS.; REINF. STL. TO BE LAPPED 30 BAR DIAM. MIN. @ SPLICES. 12. PROVIDE CLEANOUT OPENINGS AT THE BOTTOM OF GROUTED CELLS OF CONCRETE BLK. TIE COLUMNS. 13. ALL WOOD IN CONTACT WITH CONC., MASONRY OR STL. SHALL BE PRESS. TRTD. WD. STRUCTURAL LUMBER TO BE A STRESS GRADE OF MIN. F = 1200 PSI (BENDING). 14. MIN. ELECTRICAL WIRE SIZE SHALL BE #14 A.W.G. (EXCLUDING THE CONTROL WIRING). ALL CONDUCTORS SHALL BE "COPPER" WITH "THHN" INSULATION. 15. ALL RACEWAYS UNDERGROUND OR LARGER THAN 2" IN DIAM. SHALL BE GALVANIZED RIGID STL. CONDUIT OR SCHED. 40 PVC.; OTHER RACEWAYS AS PER CODE REQRMTS. 16. PROVIDE "GFI" RECEPTACLES IN BATHROOMS, AT KITCHEN COUNTERS, IN GARAGE AND OUTSIDE LOCATIONS. 17. SANITARY PLBG. PIPING TO HAVE MIN. 1/8" PER FT. PITCH AT ALL HORIZ. RUNS. PROVIDE CLEANOUTS AT THE BASE OF WASTE STACKS. 18. ALL UNDERGRD. WATER PIPING SHALL BE COPPER TYPE "K; ALL OTHER WATER PIPING SHALL BE COPPER TYPE "L". 19. PROVIDE AIR CHAMBERS AND SHUT OFF VALVES FOR ALL WATER SUPPLY PIPING AT FIXTURES; PROVIDE VACUUM BREAKER AND SHUTOFF VALVE ON ALL HOSE BIBBS. 20. A/C AIR HANDLING UNITS TO HAVE CONDENSATE SAFE WASTE WITH TRAP. GENERAL CONSTRUCTION NOTES 3'-0" DR.3'-0" DR.2'-8" DR.2'-4" DR.2'-8" DR.CLOSETCLOSETCLOSETCLOSETMASTER BEDROOM DINING KITCHEN CLOSETCLOSET CLOSET FOYER TERRACE LIVING ROOM 1'-0"4"15'-0"4"4'-4"4"4'-4"4"5'-4"4"2'-10"4"2'-6"4"1'-0"8"4'-7"8'-5" 4" 2'-1"2'-1"8"4'-10"4'-10"8"11'-8"1'-4"8" 8"6'-4"6'-4"8"7'-5"7'-5"8"6'-2"6'-6"8" TENANT TENANT OUTSIDE OUTSIDE6'-0"7'-10"14'-10" 2'-4" PLYWOOD ROOF SHEATHING A-1 Construction Plan and Notes Oct. 22, 21 DATE:A New Condo Remodel For:PALM CITY, FL13406 HARBOUR RIDGE BLVDParcel ID: 4436-605-0002-000-2BLDG. DEPT. PLAN REVISIONS:6476 Kirsten Way, Lake Worth, FL 33467Phone | 561.248.5498 Fax | 561.561.828.26451 2 3 4 FL Lic. #: AA26002780 •AR 95385THE CONSTRUCTION ANDARCHITECTURE GROUP, INC.DRAWN BY: REVIEWED BY: MANAGED BY:SANDRA PUERTASHEET: SP CA SP Dec 23, 21 CONSTRUCTION PLAN SCALE: 1/4" = 1'- 0" TYP. FIRE WALL DETAIL2 A-1 SCALE: NOT TO SCALE SCOPE OF WORKSCOPE OF WORK 1.NEW RESIDENTIAL INTERIOR REMODEL 2.REMOVE & REPLACE SANITARY FIXTURES (SEE SHEET D-1) 3.NEW WOOD FRAME WALLS AS PER PLANS (SEE SHEET A-1) 4.EXISTING W/H TO REMAIN, ELECTRICAL PANEL TO REMAIN, INSTALL NEW OUTLETS, LIGHTS & WIRING FOR NEW INTERIOR REMODEL WHERE NECESSARY (SEE SHEET E-1) 5.NEW WOOD FRAME WALL CONSTRUCTION. SEE TYP. WALL SECTION FOR MORE INFORMATION (SEE SHEET A-3) 6.IDENTIFY HARD, NON-ABSORBENT WALL FINISH AT BATH & SHOWER TO A HEIGHT OF A 6 FT. IF TILE, THE SUBSTRATE MUST BE LISTED PER ADTM C1178/1278 FOR GYPSUM OR C1288/1325 FOR CEMENT BOARD. R307.2 (SEE SHEET EP-1) 7.INSTALL NEW WOOD FLOORING AS PER PLANS (SEE SHEET D-1) 8. REMOVE & REPLACE IN THE SAME LOCATION ALL THE KITCHEN EQUIPMENT AS PER PLANS (SEE SHEET D-1) 9.REMOVE THE BATHTUB IN THE MASTER BATHROOM AND REPLACE WITH A SHOWER 10.INSTALL NEW SLIDER DOOR 11.INSTALL NEW KITCHEN ISLAND DOOR SCHEDULE WINDOW SCHEDULE NO FOUNDATION, ROOFING, OR MECHANICAL WORK NOTE: ALL WINDOWS AND DOORS TO BE NEW, UNLESS NOTED WITH "E" FOR EXISTING TO REMAIN DESIGN WIND PRESSURES WINDOWS & DOORS POS +42.9 P.S.F. NEG -57.3 P.S.F. SCALE: NOT TO SCALEA-1 TYPICAL INTERIOR WALL1 11 1