HomeMy WebLinkAboutALUMINUM FENCE SPECIFICATIONPICKET TOP 3 FT 6 FT O.C. POSTS 5/8" PICKET 1" CHANNEL (TYP) ET 1.1 CHA NEL SPACED TO REJECT 4" SPHERE (TYP) FLAT TOP 2" MAX --j POSTS ARE ROUTERED TO ACCEPT NOTCHED CHANNEL FASTENED WITH # 8 HEX HD TECH SS SCREW 1" CHANNEL CORGIN 5/8" PICKET 3/8" MIN. # 8 HEX HD TECH SS SCREW PICKET -CHANNEL ASSEMBLY DETAIL FOOTING SCHEDULE - PANEL EXPOSURE C t D FENCE HEIGHT (ft) FOOTING SIZE ( WIDTH x DEPTH) (In) POST SIZE (in) 3 12x21 2 x 2 x.06D 4 12x25 2x2x.060 4.5 12x27 2x2x.060 5 12x29 2x2x.125 6 12 x 33 2.5 x 2.5 x .075 FLUSH BOTTOM 3y2" 0 CORE DRILL FILLED WITH 6KSI MIN. EPDXY (HILTI HY-150 OR EQUIV.) WITH 3.5" EMBEDMENT INTO 3.5KSI EXISTING CONCRETE 7" MIN. EDGE DISTANCE FROM CENTER OF CORDRILL TO ANY CONCRETE FACE HD BUTTERFLY HINGE 518" PICKET (TYP) 2" x 2" x .125" WELDED UPRIGHT FT STANDARD BOTTOM 1111taffilm 6FT X 6FT GATE'DETAIL NOTE: 6 FT WIDE GATE RECEIVE 3 RAILS AND U-RAIL SEE FOOTING SCHEDULE FOR POST SIZE FOOTING 5CHEDULE - GATE EXPOSURE C * D GATE HEIGHT (ft) GATE WIDTH (ft) FOOTING SIZE ( WIDTH x DEPTH) (in) POST SIZE (in) 3 3-6 12x21 2 x 2 x.125 4 3-6 12x25 2x2x.125 4.5 3-6 12 x 27 2 x 2 x .125 5 3-6 12x29 2x2x.125 6 3-6 12x36 2.5 x2.5 x.125 tom- 72" MAX. 2" x 2" x .125" WELDED BTM U-RAIL 3 KSI CONCRETE OR GROUT FILLED BLOCK: (2) %6" X 1.5" ITW TAPCON W/ 1 1/4" EMBED & 3" MIN. EDGE DISTANCE OR WOOD (G=0.55 MIN.) X16" X 1.75" ITW TAPCON W/ 1 1/2" EMBED & 1" MIN. EDGE DISTANCE 1" CHANNEL- GATE(TYP) ON LATCH 1" CHANN GATE(T) BUTTERFL HING 5/8" PICKE (TYF 72" MAX. 1.5" x 1.5" x .125 WELDED UPRIGH' SEE FOOTING 1 SCHEDULE FOR POST SIZE TYPICAL WALL CONNECTION WITH WALL BRACKET 00.201" SEE FOOTII SCHEDUL. rnR nIKArK1c1 6 FT SEE FOOTING SCHEDULE FOR DIMENSIONS 5FT X 5FT AND SMALLER GATES DETAIL TYPICAL WALL CONNECTION WITH WALL BRACKET TO THE POST POST PANEL CHANNEL PROFILE F 1.010" 0.052" T F+ 1.03" TE�f `PROFILE 0.055" • VoG`� p� l Q0.080" 1.03" STRIP PROFILE 0.76" 0.27" PICKET PROFILE 1 0.605" � 0.042.. - •-� 0.605" GATE BOTTOM U-RAIL GENERAL NOTES 1. Design: 2020 FBC (7th edition), sec. 1616.2.1 and IBC 2018. Wind speed 75 MPH( 33 m/s ) fastest mile wind speed or 115 MPH (40 m/s ) 3-second gust- exposure C & D . 2. Materials: Post and channel material shall be aluminum 6005-T5 alloy & temper and picket material shall be 6063-T52 alloy & temper. 4TCH 3. The fence design to be used at ground surface only, with use limited to decorative barrier purposes only. This fence is not Intended to meet codes governing elevated balconies or structural railings. 4. Materials and manufacturing of Type 3 - Aluminum Fence shall be in accordance with the Aluminum Association's 2015 "Aluminum Design Manual". 5. All Type 3 -Aluminum Fence fasteners are 410 stainless steel. 6. All Type 3 - Aluminum Fence welding shall be in accordance with AWS D1.2/D1.2M and performed by American Welding Society (AWS) certified welders 7. All concrete shall be uncracked only, with a minimum compressive strength of 3000psi and shall be minimum 1.5X thicker than any anchor embedment. All epoxy and grout shall meet or exceed compressive strength of the concrete and shall be iron -free, non -shrink and non -reactive. Concrete footers shall contain min 0.1 % fibermesh admixture ' per CY. 8. All wood shall be pressure treaded No. 2 Southern Yellow Pine with minimum specific gravity, G=0.55 9. Surrounding soil to be compacted to 98% optimum density, 2500 psf minimum and shall be classified or verified by others prior to construction. 10. Upon selection product for pool barrier please follow FBC 2020-Residential section R4501.17 Residential Swimming Barrier Requirements. Fence heights less than 48" are not approved for pool applications. 11. The design and installation of electrical grounding for the Type 3 - Aluminum Fence, when required, is by others. 12. Insulate aluminum from dissimilar metals to prevent electrolysis. Insure all bare metal is protected from corrosive environments such as installation near the ocean. 13. No changes are allowed without written authorization from the engineer. 14. Copies of this drawing without an original signature and seal of the engineer are invalid. 15. No inspection was made at this jobsite and the design depicted herein is based upon data supplier by the contractor. This engineer is to not be held liable or in any way responsible for the use of any inaccurate information supplied by others. The contractor shall field verify all measurements and information used in this design before any changes are made to field condition, fabrication and the installation of the materials. (2) # 8 HEX HD TECH I TYPE 3 - ALUMINUM FENCE SS SCREW WALL BRACKET DWG NO- TYPE 3 - 115MPH WIND 2020 FBC DATE: SCALE: 2/2/2021 NTS SLUZ), % CJ NS �i No 85244 .�•• ST,f1 E •40o Al %y/0N A; `%01. JACEK SLUZYNSKI. P.E. FL #85244 BARRETTE OUTDOOR LIVING 2401 CORPORATE BLVD - BROOKSVILLE, FL 34604 (352)754-8555 NOTE: 1. POSTS SHOWN IN VIEW ARE FOR REFERNCE ONLY. 2. BUILD PANEL ACCORDING TO BOM. 3. 5/8" ALUMINUM TUBING PICKETS MINUS 4.47" = 3.86" PICKET TO PICKET SPACING THE INFORMATION CONTAINED IN THIS DRAWING IS PROTECTED BY COPYRIGHT AND PATENT LAWS OF THE UNITED STATES AND OTHER COUNTRIES. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT WRITTEN PERMISSION IS PROHIBITED. 2 EP 5/24/2021 N/A 1 CRC 10/1 /2020 200 225 REV BY DATE PCR 73002356 BLACK REPLACED CORIGIN STRIP CHANGED PICKET TO EPN-0663 DESCRIPTION 73008703 PEWTER ITEM NO. 1 2 3 4 0 1.50 8.50 54.50 73008903 73020099 WHITE MATTE BLACK DESCRIPTION QTY. RES FENCE -RAIL 15HOL 72.3 BK 2 RES FENCE -RAIL 72.3 BK 1 5/8X53.75X045 AL -TUB 54" FT BK-H 15 CORIGIN BUMP STRIP #3-2.235"CTC 6 ;ANCES FRACTION ±1 /16 XX +0.01 XXX ±0.005 ANGLE ±1.0° FINISH 125 RMS UNLESS OTHERWISE SPECIFIED a BARRETTE Outdoor Living Driveworks 10/6/2016 PS CAll V!_% 1-1 ATT/1P1 PY1 a0%1i —w.— SHEET 1 OF 1 REVISION SCALE 1:20 WEIGHT: 11.37 A2 73002 SFT X SFT AND SMALLER GATES DETAIL 73009471 73009690 BLACK PEWTER 1" CHANNEL 60' MAX. --+I LATCH GATE(TYP) BUTTERFLY HINGE I s/8"PI(TMP) I ITEM NO. 1.5" x 1.5" x .125" 60' MAX. 1 WELDED UPRIGHT SEE FOOTING 2 SCHEDULE FOR POST SIZE _pool 15 MI 3 SEE FOOTING 4- 46.50 SCHEDULE FOR DIMENSIONS THE INFORMATION CONTAINED IN THIS DRAWING IS PROTECTED BY COPYRIGHT AND PATENT LAWS OF THE UNITED STATES AND OTHER COUNTRIES. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT WRITTEN PERMISSION IS PROHIBITED. 1 1 CRC 1 10/1/2020 REV I BY I DATE S-A y CHANGED PICKET TO EPN-0663. PCR I DESCRIPTION X 1.50 54.50 73009909 I 73020101 WHITE MATTE BLACK DESCRIPTION 1.5x55.5x09 AL -TUB MF RES G8 RAIL NHOL 4'W STRT 43.5 RES GATE RAIL 9HOL 4'W STRT 43.5 (EPN-0663) .615"X.615"X53.75" EXTR TOLERANCES FRACTION ±1/16 xx ±0.01 xxx ±0.005 ANGLE ±1.0° FINISH 1125 RMS UNLESS OTHERWISE SPECIFIED Notes: 1. Gate includes self closing Boerboel butterfly hinges 2. Each gate will have Child Safety Gate Latch by National Hardware N346-210 (see attached specification sheet) 3. Reference Engineering page showing picket width is 5/8". 5/8" Aluminum tube pickets minus 4.47" = 3.845" vertical picket to vertical picket spacing Notes: 1. Spacing: 4.47 In. QTY. 2 1 2 9 BARRETTE 0W-0, Outdoor Living C.CLARK 11-9-2018 PS 448 RESP FT 3R BK STR8 FB GT SHEET 1 OF 1 1 REVISION IPARTNUMBER SCALE 1:12 0 73009471 WEIGHT: 12.54 =Sn "900 1 Revision March 2019 Date 2 3116" [ 56mm ] l.. GAP VARIANCE 112" (13mm) - 1 1/2" (38mm) II N E CD N � 1 5/16" C E N 2 7/16" 62mm ] 1 7mm I 0 1 1/8" Material: POLYMER Finish: BLACK Fasteners: (1) #6 X 3/4", PAN HEAD, TYPE AB, TAPPING SCREW (12) #10 X 1 ", PAN HEAD, TYPE AB, TAPPING SCREW (2) #10 X1-5/8", PAN HEAD, TYPE AB, TAPPING SCREW (2) KEYS, BLANK=KW1 SN H6208 N 346-210 Dimensions are nominal Family Name SKU and subject to change. MAGNA LATCH, TOP PULL 02019 Spectrum Brands, Inc. Description DO NOT SCALE