HomeMy WebLinkAboutALUMINUM FENCE SPECIFICATIONPICKET TOP
3 FT
6 FT O.C. POSTS
5/8" PICKET 1" CHANNEL
(TYP) ET 1.1 CHA NEL
SPACED TO REJECT
4" SPHERE (TYP)
FLAT TOP
2" MAX --j
POSTS ARE ROUTERED TO ACCEPT
NOTCHED CHANNEL FASTENED WITH
# 8 HEX HD TECH SS SCREW
1" CHANNEL
CORGIN
5/8" PICKET
3/8" MIN.
# 8 HEX HD TECH
SS SCREW
PICKET -CHANNEL
ASSEMBLY DETAIL
FOOTING SCHEDULE - PANEL
EXPOSURE C t D
FENCE HEIGHT
(ft)
FOOTING SIZE
( WIDTH x DEPTH)
(In)
POST SIZE
(in)
3
12x21
2 x 2 x.06D
4
12x25
2x2x.060
4.5
12x27
2x2x.060
5
12x29
2x2x.125
6
12 x 33
2.5 x 2.5 x .075
FLUSH BOTTOM
3y2" 0 CORE DRILL
FILLED WITH 6KSI MIN.
EPDXY (HILTI HY-150 OR EQUIV.)
WITH 3.5" EMBEDMENT INTO 3.5KSI
EXISTING CONCRETE
7" MIN. EDGE DISTANCE FROM CENTER
OF CORDRILL TO ANY CONCRETE FACE
HD BUTTERFLY
HINGE
518" PICKET
(TYP)
2" x 2" x .125"
WELDED UPRIGHT
FT
STANDARD BOTTOM
1111taffilm
6FT X 6FT GATE'DETAIL
NOTE: 6 FT WIDE GATE RECEIVE 3 RAILS AND U-RAIL
SEE FOOTING
SCHEDULE FOR POST
SIZE
FOOTING 5CHEDULE - GATE
EXPOSURE C * D
GATE HEIGHT
(ft)
GATE WIDTH
(ft)
FOOTING SIZE
( WIDTH x DEPTH)
(in)
POST SIZE
(in)
3
3-6
12x21
2 x 2 x.125
4
3-6
12x25
2x2x.125
4.5
3-6
12 x 27
2 x 2 x .125
5
3-6
12x29
2x2x.125
6
3-6
12x36
2.5 x2.5 x.125
tom- 72" MAX.
2" x 2" x .125"
WELDED BTM U-RAIL
3 KSI CONCRETE OR
GROUT FILLED BLOCK:
(2) %6" X 1.5" ITW
TAPCON W/ 1 1/4"
EMBED & 3" MIN. EDGE
DISTANCE
OR
WOOD (G=0.55 MIN.)
X16" X 1.75" ITW
TAPCON W/ 1 1/2"
EMBED & 1" MIN. EDGE
DISTANCE
1" CHANNEL-
GATE(TYP)
ON
LATCH
1" CHANN
GATE(T)
BUTTERFL
HING
5/8" PICKE
(TYF
72" MAX.
1.5" x 1.5" x .125
WELDED UPRIGH'
SEE FOOTING
1 SCHEDULE FOR POST
SIZE
TYPICAL WALL CONNECTION
WITH WALL BRACKET
00.201"
SEE FOOTII
SCHEDUL.
rnR nIKArK1c1
6 FT
SEE FOOTING
SCHEDULE FOR DIMENSIONS
5FT X 5FT AND SMALLER GATES
DETAIL
TYPICAL WALL CONNECTION WITH WALL
BRACKET TO THE POST
POST
PANEL CHANNEL PROFILE
F
1.010" 0.052"
T F+
1.03"
TE�f `PROFILE
0.055"
• VoG`� p�
l Q0.080"
1.03"
STRIP PROFILE
0.76"
0.27"
PICKET PROFILE
1
0.605" � 0.042..
- •-� 0.605"
GATE BOTTOM U-RAIL
GENERAL NOTES
1. Design: 2020 FBC (7th edition), sec. 1616.2.1 and IBC 2018.
Wind speed 75 MPH( 33 m/s ) fastest mile wind speed or 115 MPH (40 m/s ) 3-second gust- exposure C & D .
2. Materials: Post and channel material shall be aluminum 6005-T5 alloy & temper and picket material shall be
6063-T52 alloy & temper.
4TCH 3. The fence design to be used at ground surface only, with use limited to decorative barrier purposes only. This fence is
not Intended to meet codes governing elevated balconies or structural railings.
4. Materials and manufacturing of Type 3 - Aluminum Fence shall be in accordance with the
Aluminum Association's 2015 "Aluminum Design Manual".
5. All Type 3 -Aluminum Fence fasteners are 410 stainless steel.
6. All Type 3 - Aluminum Fence welding shall be in accordance with AWS D1.2/D1.2M and
performed by American Welding Society (AWS) certified welders
7. All concrete shall be uncracked only, with a minimum compressive strength of 3000psi and shall be minimum 1.5X
thicker than any anchor embedment. All epoxy and grout shall meet or exceed compressive strength of the concrete
and shall be iron -free, non -shrink and non -reactive. Concrete footers shall contain min 0.1 % fibermesh admixture
' per CY.
8. All wood shall be pressure treaded No. 2 Southern Yellow Pine with minimum specific gravity, G=0.55
9. Surrounding soil to be compacted to 98% optimum density, 2500 psf minimum and
shall be classified or verified by others prior to construction.
10. Upon selection product for pool barrier please follow FBC 2020-Residential section R4501.17 Residential Swimming
Barrier Requirements. Fence heights less than 48" are not approved for pool applications.
11. The design and installation of electrical grounding for the Type 3 - Aluminum Fence, when required, is by others.
12. Insulate aluminum from dissimilar metals to prevent electrolysis. Insure all bare metal is protected from corrosive
environments such as installation near the ocean.
13. No changes are allowed without written authorization from the engineer.
14. Copies of this drawing without an original signature and seal of the engineer are invalid.
15. No inspection was made at this jobsite and the design depicted herein is based upon
data supplier by the contractor. This engineer is to not be held liable or in any way
responsible for the use of any inaccurate information supplied by others. The contractor
shall field verify all measurements and information used in this design before any changes
are made to field condition, fabrication and the installation of the materials.
(2) # 8 HEX HD TECH I TYPE 3 - ALUMINUM FENCE
SS SCREW
WALL BRACKET
DWG
NO- TYPE 3 - 115MPH
WIND 2020 FBC
DATE: SCALE:
2/2/2021 NTS
SLUZ),
% CJ NS �i
No 85244
.�•• ST,f1 E •40o
Al
%y/0N A; `%01.
JACEK SLUZYNSKI. P.E. FL #85244
BARRETTE OUTDOOR LIVING
2401 CORPORATE BLVD - BROOKSVILLE, FL 34604
(352)754-8555
NOTE:
1. POSTS SHOWN IN VIEW ARE FOR REFERNCE ONLY.
2. BUILD PANEL ACCORDING TO BOM.
3. 5/8" ALUMINUM TUBING PICKETS
MINUS 4.47" = 3.86" PICKET TO PICKET
SPACING
THE INFORMATION CONTAINED IN
THIS DRAWING IS PROTECTED BY
COPYRIGHT AND PATENT LAWS
OF THE UNITED STATES AND
OTHER COUNTRIES. ANY
REPRODUCTION IN PART OR AS A
WHOLE WITHOUT WRITTEN
PERMISSION IS PROHIBITED.
2 EP 5/24/2021 N/A
1 CRC 10/1 /2020 200 225
REV BY DATE PCR
73002356
BLACK
REPLACED CORIGIN STRIP
CHANGED PICKET TO EPN-0663
DESCRIPTION
73008703
PEWTER
ITEM NO.
1
2
3
4
0
1.50
8.50
54.50
73008903 73020099
WHITE MATTE BLACK
DESCRIPTION QTY.
RES FENCE -RAIL 15HOL 72.3 BK 2
RES FENCE -RAIL 72.3 BK 1
5/8X53.75X045 AL -TUB 54" FT BK-H 15
CORIGIN BUMP STRIP #3-2.235"CTC 6
;ANCES
FRACTION
±1 /16
XX
+0.01
XXX
±0.005
ANGLE
±1.0°
FINISH
125 RMS
UNLESS OTHERWISE SPECIFIED
a BARRETTE
Outdoor Living
Driveworks 10/6/2016 PS
CAll V!_% 1-1 ATT/1P1 PY1 a0%1i —w.—
SHEET 1 OF 1 REVISION
SCALE 1:20
WEIGHT: 11.37 A2
73002
SFT X SFT AND SMALLER GATES DETAIL 73009471 73009690
BLACK PEWTER
1" CHANNEL
60' MAX. --+I LATCH
GATE(TYP)
BUTTERFLY
HINGE I
s/8"PI(TMP) I ITEM NO.
1.5" x 1.5" x .125" 60' MAX. 1
WELDED UPRIGHT
SEE FOOTING 2
SCHEDULE FOR POST
SIZE
_pool 15 MI 3
SEE FOOTING 4- 46.50
SCHEDULE
FOR DIMENSIONS
THE INFORMATION CONTAINED IN
THIS DRAWING IS PROTECTED BY
COPYRIGHT AND PATENT LAWS
OF THE UNITED STATES AND
OTHER COUNTRIES. ANY
REPRODUCTION IN PART OR AS A
WHOLE WITHOUT WRITTEN
PERMISSION IS PROHIBITED.
1 1 CRC 1 10/1/2020
REV I BY I DATE
S-A y CHANGED PICKET TO EPN-0663.
PCR I DESCRIPTION
X
1.50
54.50
73009909 I 73020101
WHITE MATTE BLACK
DESCRIPTION
1.5x55.5x09 AL -TUB MF
RES G8 RAIL NHOL 4'W STRT 43.5
RES GATE RAIL 9HOL 4'W STRT 43.5
(EPN-0663) .615"X.615"X53.75" EXTR
TOLERANCES
FRACTION
±1/16
xx
±0.01
xxx
±0.005
ANGLE
±1.0°
FINISH
1125 RMS
UNLESS OTHERWISE SPECIFIED
Notes:
1. Gate includes self closing
Boerboel butterfly hinges
2. Each gate will have Child
Safety Gate Latch by National
Hardware N346-210 (see
attached specification sheet)
3. Reference Engineering page
showing picket width is 5/8". 5/8"
Aluminum tube pickets minus
4.47" = 3.845" vertical picket to
vertical picket spacing
Notes:
1. Spacing: 4.47 In.
QTY.
2
1
2
9
BARRETTE
0W-0,
Outdoor Living
C.CLARK 11-9-2018 PS
448 RESP FT 3R BK STR8 FB GT
SHEET 1 OF 1 1 REVISION IPARTNUMBER
SCALE 1:12 0 73009471
WEIGHT: 12.54
=Sn
"900
1
Revision
March 2019
Date
2 3116"
[ 56mm ]
l..
GAP VARIANCE
112" (13mm) - 1 1/2" (38mm)
II N E
CD
N �
1 5/16"
C E
N
2 7/16"
62mm ]
1
7mm
I
0
1 1/8"
Material: POLYMER
Finish: BLACK
Fasteners: (1) #6 X 3/4", PAN HEAD, TYPE AB, TAPPING SCREW
(12) #10 X 1 ", PAN HEAD, TYPE AB, TAPPING SCREW
(2) #10 X1-5/8", PAN HEAD, TYPE AB, TAPPING SCREW
(2) KEYS, BLANK=KW1
SN H6208 N 346-210
Dimensions are nominal Family Name SKU
and subject to change. MAGNA LATCH, TOP PULL
02019 Spectrum Brands, Inc.
Description
DO NOT SCALE