Loading...
HomeMy WebLinkAboutEnergy Efficiency Code9 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: GREEN ADDITION Street: 109 MAIN STREET City, State, Zip: FT. PIERCE, FL, Owner. Design Location: FL, Fort Pierce 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms(Bedrms In Addition) 5. Is this a worstease7 6. Conditioned floor area above grade (W) Conditioned floor area below grade (fit') 7. Windows(188.0 sgfk) Description a. U-Factor. Sgl, U=1,D4 SHGC: SHGC=0.25 b. U-Factor_ NIA SHGC: c. U-Factor, NIA SHGC: d, U-Factor, N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: B ilder Name: P rmit Office: rmit Number. ST. Lucie County, Perm ittingCpunty: St. Lucie (Florida Climate Zone 2 ) Addition 9. Wall Types(1344.0 sgft.) Insulation Area Single-family a. Concrete Block - Int Insul, Exterior R=4.2 1000,00 W b. Concrete Block - Int Insui, Exterior R=5,4 344.00 ft' 1 c. N/A R= ft. 2(0) d. NIA R= ftz No 10. Ceiling Types (1171.0 sgft.) Insulation Area a. Under Attic (Vented) R=19.0 960-00 fF 1171 b. Under Attic (Vented) R=30.0 211.00 fit 0 c. NIA R= ftz 11, Ducts R tt2 Area a. Sup: Attic, Ret: Attic, AW ZONE 1 6 234.2 188.00 ftz fiz 12. Cooling systems kBtu/hr Efficiency a. Central Unit 30.0 SEER:16.50 ft 13. Heating systems kBtulhr Efficiency ttz , a. Electric Strip Heat 21.0 COP:1.00 8. Floor, Types (1171.0 OfL) Insulation a, Slab -On -Grade Edge Insulation R=0.0 b. NIA R= c. N/A R= 1.333 ft. 0.250 14' Hot water systems - Replacement equipment a, Electric Area 1171.00 W b, Conservation features ftz None' ft2 15.. Credits Cap: 5.0.gallons EF 0.970 Pstat I Glass/Floor Area: 0.161 Total Proposed Modified Loads: 40,09 n w Total Baseline Loads: 40' 18 PA I hereby certify that the plans and specifications cover this calculation are in compliance with the Florida En Code, PREPARE Y:�.- DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWN ER/AG ENT: .... .................. ............. ................... .............................. _... _._..................................... ............ ........................ DATE: _ Review of the plans and specifications covered by this calculation indicates compliance With the Florida Energy Code. Before construction is completed this building Will be inspected for compliance with Section 553.008 Florida Statutes.. BUILDING OFFICIAL: DATE: ._ ....... ....... -....._...... -- - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -seated in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.40 ACH50 (R402.4.1.2). � lzm, , 6/261202010:03 AM EnergyGaugeO USA 6,0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page: I of 4 " 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX` =100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Sfnale-famfly b) Return ducts R. 6.0 c) AHU location ZONE 1 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 20.0 a) Split system SEER 5. is this a worst case? (yes/no) 6. No b) Single package .SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1171 d) Room. unIUPTAC EER e) Other . 16.5 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.040 b) Solar Heat Gain -Coefficient (SHGC) 7b. 0.250 c) Area 7c. 188.0 8. Skylights a) U-factor(weighted average) Ba. NA b,) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floortype, insulation a) Stab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior. 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (insulation R-value) 9a: 0.0 9b. 9c. 10A1. 10A2. varies IOB1. 110132. 14. Heating system: Capacity21.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 10 d) Gas furnace, natural .gas AFUE e) Gas furnace, LPG . AFUE 0 Other. 15. Water heating system a) Electric resistance.._ EF 0.97 b) Gas fired, natural gas EF c) Gas fired, LPG EF . d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatReG% g) Other 16. HVAC credits claimed (Performance Method) 11. Ceiling type and. Insulation level a) Ceiling fans a) Under attic lie. varies b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c, d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, If not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) In this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 109 MAIN STREET City/FL Zfp: FT. PIERCE, FL 6/25/2020 10:03:07 AM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 - FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: GREEN ADDITION Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1171 Lot # Owner Name: Total Stories: i BlocklSubdivision: # or Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street 109 MAIN STREET Permit Office: Cross Ventilation: County: St Lucie Jurisdiction: Whole House Fan: City, State, Zip: Ft. PIERCE, Family Type: Single-family FL, NewtF_xtsting- Addition Comment CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location -...._-......�_._._.r_ _._._________., TMY Site 97.5 % 2.5 % ._..,._... Winter Summer Degree Days Moisture Range .......... _......... _.._..............................................._......._._...._..__..........__.................__.._...._..__...._. FL, Fort Pierce FL_VERO SEACI- MUNI 38 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Biockl 1171 9368 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled 4 Heated 1 ZONE 1. 1171 9368:. Yes 2 2 ' 1 Yes."- Yea Yes • FLOORS - _,_..._. Floor Type space Perimeter R Value y Area Tile Wood Carpet:_ 1 Stab -On -Grade Edge insulatio - ,ZOkI:.1, 178 0 0 0 1 ROOF Roof Gable Roof Red Solar SA Emitt Emitt begk Pitch 11 # Type Materials Area Area Color Barr Abidr. Tested Tested. .Insul. (deg) 1 Hip Composition shingles 1207 to Oft' Medium N 0.96 No 0.9 No 0 14 ATTIC V # Type _....._..._....._ Ventilation Vent Ratio (1 In) _ Area RBS IRCC _..____.__..__._._._._._._......---- 1 _-------- __....---..----..__ Full attic. ____ _._._ .___..___......___ Vented 150 1171 fe N N CEILING # Ceiling Type Spaoe R--Value Ins Type Area Framing Free Truss Type _.__..........__._._..._-....-__...... 1 Under Attic (Vented) _ ZONE 1 19 Blown 960 fN 0.11 Wood 2 Under Attic (Vented) ZONE 1 30 Blown 211 fe 0.11 Wood 6/25/202010:03 AM EnergyGaugeV USA 6.0.02 (Rev. I) - FlaRes2017 FSC 6th Edition (2017) Compliant Software Page 2 of 4 ' FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below RXalue ...-Fra -_Absor__.GradaV*._ Value. cti� I N Exterior Concrete Block - Int insul ZONE 1 4.2 48 8 384.0 112 4.2 0 0.75 0 2 S Exterior Concrete Block - Int Insul ZONE 1 4.2 31 8 248.0 ft2 4.2 0 0175 a 3 E Exterior Concrete Block - Int Insul ZONE 1 4.2 23 8 184-.0 ft' 4.2 0 0.75 0 4 W Exterior Concrete Block - Int Insul ZONE 1 4.2 23 8 184.0 IP 4.2 0 0.76 0 5 S Exterior Concrete Block - Int Insul ZONE 1 6.4 17 a 136.0 I'll SA a 0.75 a 6 E Exterior Concrete Block - Int Insul ZONE 1 5.4 13 8 104.0 W 5.4 0 015 0 7 W Exterior Concrete Block - Int Insul ZONE 1 5.4 13 a 104.0 11? 5.4 0 0.76 a DOORS # Omt Door Type Space Storms. U-Value Width Height Area Ft In Ft In I N Insulated ZONE 1 . .............. None . . .... . . .46 3 7 21 ft" WINDOWS Orientation shown Is the entered, Pro Msed orientation. Wall Overhang # . ... ... . ......... . ... . . . .......... . ...... . ... Omt ID Frame Panes NFRC ­,.­.­....­­ .............. . . ...... . .............. ....... . .......... U-Factor SHGC Imp ...... . .. . .......... ....... . .... . ....................... .......... Area Depth ....... . . . .......... ­1 .. . ... ........ Separabon. IntShAde . . . . ............... . ..... ScreenIng. 1 N I Metal Low-S Single Yes I.0 0.25 Y 16.0 ft2 I ft4 In I ftO in Drapesiblinds None 2 N 1 Metal Low-E Single Yes 1.04 0.25 Y 24.0 It" 1 ft4 In I ft0in Drapes/blinds. None 3 a 3 Metal Low-E Single Yes 1,04 0.26 Y 24.0 fe I A 4 In I ff0ln Drapes/blinds None 4 S 2 Metal Low-E Single Yes 1.04 026 Y 9,0 ft2 I It 4'ln I R 0 In Drapes/blinds, None 5 S 2 Metal -Low-E Single Yes'- 1,04. 0,25 Y &C fig I ft4in I ItOin Dra Inds None �6 W 4 Metal Low-;ESin.gle S Yes,.;; < 1,04 0.26 Y 9.0 fe .1ft41n,,:1-ft0Inr,,,..0 peslbriiids None* - k7 - S 6 Metal L6w-E Single Yes-,-f, 1,04 -0.25 Y 24.0 fV I*ft4in T400 Drapesiblinds None 8 E 'Yes 6 Metal Low-E Single 0.25 Y 56,0 f� I ft4in' None 9 W 7 Metal Low-E Single Yes --.,.1.04 US Y 211.0 fe 11114 in I ff 0 In Drapes/blinds None INFILTRATION Scope Method SLA CFM so ELA EqLA ACH ACH 60 ............ . ...... ........ . ­­.­ ................. . ....... ................. . ..... . . ................. . .... ................ . .................................. I Wholehouse Proposed CFM(50) .000326 . . ............. . . . .......... . . ... . ................ 11000 $4.9 103.25 .1128 7 ._.­.__,...._­ . . ............ 6,4048 . ...... . ....... . ........... HEATING SY3,TEM System Type Efficiency ... . . ..... Capa!R�L, . . ...... Block D6cts I Electric Strip HeaVaislinglao None CORI 21 kBtulhr 1 sys#1. COOLING SYSTEM System Type Subtype Efficiency capacity Air Flow SHR Block Ducts I Central Unit/Exletingtconfirme None SEER* 16.5 30 kStuthr 900 clin 0.75. 1 sys#1 612512020'10;03 AM EnerqyGaugeO USA 6.0.02 (Rev. 1) - FlaRes20117 FBC 6th Edition (2017) Compliant Software Page 3 of 4 " FORM R405:2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM System Type SubType Location EF Cap Use setpnt Conservation 1 Electric None ZONE 1 0.97 60 gal 50981 120 deg None SOLAR HOT WATER SYSTEM v FSEC Collector immo Cert # ..... ..... ......... -- -------------- . . .. . .... Company Nam . ................... System Model# Collector Model # Area Volume FEF . . . . - None None . ........ ftz DUCTS Supply Return Air CFM 26 CF425 HVAC # # Location R-Valve Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Coal I Attic 6 234.2 ft Attic . . ............... . .. .. . 58.55 It Default Leakage . ..... . .............. ZONE 1 .......... ........................... . . .... .......... .... . ..... ............. (Default) (Default) ...... . . .. ....... 1 1 TEMPERATURES Pr6gramable Thermostat* Y Calling Fans: Cooling Jan Heating Jan H reb Feb a M ar Mar A Apr' y Me J,'j'n Jul I I Ma n n Jul nAu u Se p Oct Oct W Nov H:De c a, - Venting Jan Feb Mar Apr May Jun Jul u Seo Oct Molv, Dec . . ....... .. ...... Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 a 9 10 11 12 .............. . .... . ... Cooling W) 78 ...... 78 n . . . ...... .. .......... 78 78 78 78 78 80 ................. so 8b 60 80 so 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78, 78 78 78 78, 78 78 78 78 78 78 PM _74, 78 78, 78, 78 78 78 .78' —,-78 78 ,'78 AM 66 66, - 68%, 68 68 68 '68,`-' 66 68, 68 68,... 68 68 68 68 6V 66; , 66 Heating MEH) AM S6 as 66 66 68 68 68'. 68 68 68 . e, J. PM 68 68 68' ',68 '68, 68 68 68 6 8' .,66 66 VASS Mass Type Area Thickness Furniture Fractl on Space Default (8 1bs/ .ft. . ... . 0 ft's .................................. . ........ Oft 0.3 ZONE 1 6/25/2020 10:03 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4