Loading...
HomeMy WebLinkAboutProduct Approval9/21/2018 Florida Building Code Online BCIS Home ; Log In ; User Registration = Hot Topics ; Submit Surcharge I Stats & Facts Publications i Contact Us ! BCIS Site Map j Links Search F�riA da Product Approval ros USER: Public User ProductAl Approval Menu > Product or Application Search > Application List > Application Detail i FL # FL16638-R2 Application Type Revision Code. Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Greg Keeler greg.keeler@owenscorning.com Greg Keeler 2790 Columbus Road Granville, -OH 43023 (740)321-6345- greg.keeler@owenscorning.com Roofing Asphalt Shingles Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL16638 R2 COI OCR13001.2 2017 FBC Evaluation Report - Shingles Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code final.pdf 1507.2.5 1507.2.7.1 .-..---"_ --- —1 CAC—Cl7fk-D—Do%7fidlRQ7.•.0%4i70%4,4 110 9/29/2018 i, Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 2 Option B 09/30/2017 10/03/2017 10/04/2017 12/12/2017 FL # Model, Number or Name Description 16638.1 SUPREME & CLASSIC ^ AC438 3-tab asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL16638 R2 II OCR13001.2 2017 FBC Evaluation Report - Shingles final.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL16638 R2 AE OCR13001.2 2017 FBC Evaluation Report - Shingles final.pd Created by Independent Third Party: Yes Bach fkxxt Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copytight 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee: However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with, an email address which can be made available to the public. To determine if you area licensee under Chapter 455, F.S., please click here . .. Product Approval Accepts: . S�C111'3.1:fthrTlTiCS, ,. � .. •. _. _._ ___ �.� _____n____--._.c. r. ivy.. �r.__� �____wni nrnn_nvuwcr_�.r��n..ni rwr..._n�c�_n _noi nr..r�o o-n..oi n.roi n,� non 7.I �,.• ¢ �� TECHNICAL SERVICES, LLC EVALUATION REPORT Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 FLORIDA BUILDING CODE, 6TH EDITION (2017) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC 1 Owens Corning Parkway Toledo, OH 43657 (800) -438-7465 www.owenscorning.com Manufacturing Plants: Quality Assurance: SCOPE Atlanta, GA Compton, CA Denver, CO Irving, TX Kearny, NJ Medina, OH Memphis, TN Portland, OR Summit, IL UL LLC (QUA9625) Category: Roofing Subcategory: Asphalt Shingles . Code Sections: 1507.2.5, 1507.2.7.1 Properties: Physical properties, Wind Resistance REFERENCES Issued September 30, 2017 ED-tilt Report No. Standard Year UL LLC (TST9628) 13NK05962 ASTM D 3462 2010A UL LLC (TST9628) 13NK05962 ASTM D 3161 2016 UL LLC (TST9628) 13NK05962 ASTM D 7158 2011 UL LLC (TST9628) 13NK05962 TAS 100 1995 UL LLC (TST9628) 13NK05962 ASTM G 155 2005a UL LLC (TST9628) 13NK05962 AC438 2011 PRODUCT DESCRIPTION AND APPLICATION SUPREME®& ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, 3-tab asphalt CLASSIC® roof shingle. Unless otherwise noted, the following application, details shall be followed for New and Existing construction. Basic Wind Speed: Max. 194 mph Deck (Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC and manufacturer's requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the OWENS CORNING when installing at slope greater than 2:12. Installation: Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Nailing requirements are detailed below in Figures 1 & 2. OCR13001.2 FL 16638-112 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC 36, OWENS CORNING ROOFING AND ASPHALT LLC Asphalt Shingles Min. 12 ga. corrosion resistant roofing nail with min. 318" diameter head 11" 1° 1° Continuous, facto"ppiied tab sealant 12" O O O 5 5/8" 5" Figure 1. SUPREME® and CLASSIC® 4 Nail Pattern 36" Min. 12.ga. corrosion resistant roofing nail With min. 318" diameter head Continuous, factory -applied. tab sealant O O 0 O 0 Figure 2. SUPREME® and CLASSIC® 6 Nail Pattern LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) This evaluation report is not for use in the HVHZ. 3) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 5) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 6) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive detail shall prevail. 7) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. OCR13001.2 Fl- 16638-R2 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. OWENS CORNING ROOFING AND ASPHALT LLC CREEKAsphalt Shingles N TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. ��►►►rlurrr� ������ �� INV No 74021 — :XZ STATE OFAl 0 R t O, `�� e--S;0NA' 0 1111110,4 � CERTIFICATION OF INDEPENDENCE 2017.09.30 15:36:37 -04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products - under this evaluation. Zachary. R. Priest, P.E. does not have, nor will acquire; a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR33001.2 FL 16638-R2 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.