HomeMy WebLinkAboutProduct Approval9/21/2018
Florida Building Code Online
BCIS Home ; Log In ; User Registration = Hot Topics ; Submit Surcharge I Stats & Facts Publications i Contact Us ! BCIS Site Map j Links Search
F�riA
da
Product Approval
ros USER: Public User
ProductAl
Approval Menu > Product or Application Search > Application List > Application Detail
i FL # FL16638-R2
Application Type Revision
Code. Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Greg Keeler
greg.keeler@owenscorning.com
Greg Keeler
2790 Columbus Road
Granville, -OH 43023
(740)321-6345-
greg.keeler@owenscorning.com
Roofing
Asphalt Shingles
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL16638 R2 COI OCR13001.2 2017 FBC Evaluation Report - Shingles
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
final.pdf
1507.2.5
1507.2.7.1
.-..---"_ --- —1 CAC—Cl7fk-D—Do%7fidlRQ7.•.0%4i70%4,4 110
9/29/2018
i,
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 2 Option B
09/30/2017
10/03/2017
10/04/2017
12/12/2017
FL #
Model, Number or Name
Description
16638.1
SUPREME & CLASSIC ^
AC438 3-tab asphalt shingles
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16638 R2 II OCR13001.2 2017 FBC Evaluation Report -
Shingles final.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL16638 R2 AE OCR13001.2 2017 FBC Evaluation Report -
Shingles final.pd
Created by Independent Third Party: Yes
Bach fkxxt
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copytight 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee: However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with, an email address which can be made available to the public. To determine if you area licensee under Chapter 455, F.S., please click here .
.. Product Approval Accepts: .
S�C111'3.1:fthrTlTiCS,
,. � .. •. _. _._ ___ �.� _____n____--._.c. r. ivy.. �r.__� �____wni nrnn_nvuwcr_�.r��n..ni rwr..._n�c�_n _noi nr..r�o o-n..oi n.roi n,� non
7.I �,.•
¢
��
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
FLORIDA BUILDING CODE, 6TH EDITION (2017)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC
1 Owens Corning Parkway
Toledo, OH 43657
(800) -438-7465
www.owenscorning.com
Manufacturing Plants:
Quality Assurance:
SCOPE
Atlanta, GA
Compton, CA
Denver, CO
Irving, TX
Kearny, NJ
Medina, OH
Memphis, TN
Portland, OR
Summit, IL
UL LLC (QUA9625)
Category: Roofing
Subcategory: Asphalt Shingles .
Code Sections: 1507.2.5, 1507.2.7.1
Properties: Physical properties, Wind Resistance
REFERENCES
Issued September 30, 2017
ED-tilt
Report No.
Standard
Year
UL LLC (TST9628)
13NK05962
ASTM D 3462
2010A
UL LLC (TST9628)
13NK05962
ASTM D 3161
2016
UL LLC (TST9628)
13NK05962
ASTM D 7158
2011
UL LLC (TST9628)
13NK05962
TAS 100
1995
UL LLC (TST9628)
13NK05962
ASTM G 155
2005a
UL LLC (TST9628)
13NK05962
AC438
2011
PRODUCT DESCRIPTION AND APPLICATION
SUPREME®& ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, 3-tab asphalt
CLASSIC® roof shingle. Unless otherwise noted, the following application, details shall be followed
for New and Existing construction.
Basic Wind Speed: Max. 194 mph
Deck (Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
Underlayment: In accordance with FBC and manufacturer's requirements.
Min. slope: 2:12 and in accordance with FBC requirements. Contact
the OWENS CORNING when installing at slope greater
than 2:12.
Installation: Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Nailing requirements are detailed below in
Figures 1 & 2.
OCR13001.2 FL 16638-112 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TECHNICAL SERVICES, LLC
36,
OWENS CORNING ROOFING AND ASPHALT LLC
Asphalt Shingles
Min. 12 ga. corrosion resistant roofing nail
with min. 318" diameter head
11"
1° 1°
Continuous, facto"ppiied tab sealant
12"
O O O
5 5/8" 5"
Figure 1. SUPREME® and CLASSIC®
4 Nail Pattern
36"
Min. 12.ga. corrosion resistant roofing nail
With min. 318" diameter head
Continuous, factory -applied. tab sealant
O O 0 O 0
Figure 2. SUPREME® and CLASSIC®
6 Nail Pattern
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) This evaluation report is not for use in the HVHZ.
3) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
5) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
6) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
detail shall prevail.
7) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
OCR13001.2 Fl- 16638-R2 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
OWENS CORNING ROOFING AND ASPHALT LLC
CREEKAsphalt Shingles
N
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
��►►►rlurrr�
������
��
INV
No 74021
—
:XZ
STATE OFAl
0 R t O, `��
e--S;0NA' 0
1111110,4
�
CERTIFICATION OF INDEPENDENCE
2017.09.30
15:36:37
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products -
under this evaluation.
Zachary. R. Priest, P.E. does not have, nor will acquire; a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR33001.2 FL 16638-R2 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not