HomeMy WebLinkAboutBARCLAY BEACH CLUBBARCLAY BEACH CLUB 2800 NORTH HIGHWAY A1A FORT PIERCE, FL 34949 1.NO FIRE ALARM WORK IS PERFORMED UNDER THIS PERMIT. 2.NO STRUCTURAL WORK, DESIGN CHANGES, OR ADDITIONS ARE PERFORMED UNDER THIS PERMIT THEREFORE ARCHITECTURAL DRAWINGS ARE NOT PROVIDED OR REQUIRED. a.ALL NEW WORK AND EXISTING CONSTRUCTION ARE CLEARLY IDENTIFY. DRAWINGS ARE OF SUFFICIENT CLARITY AND QUALITY TO EFFECTIVELY CONVEY THE NATURE AND SCOPE OF THE PROPOSED WORK. b.THE CLASS OF REHAB IS “RENOVATION” PER CHAPTER 43, SECTION 43.4… “THE REPLACEMENT IN KIND, STRENGTHENING OR UPGRADING OF BUILDING ELEMENTS, MATERIALS, EQUIPMENT OR FIXTURES THAT DOES NOT RESULT IN THE RECONFIGURATION OF THE BUILDING SPACES WITHIN”. c.WORK UNDER THIS PERMIT MEETS THE DEFINITION FROM FBC, EXISTING AS “ALTERATION - LEVEL 1” AND IS COVERED BY THE PROVISIONS OF CHAPTER 7. IAW CHAPTER 7, THE “ALTERATIONS” MADE BY THIS PERMIT MEET THE STANDARDS OF CONFORMANCE FOR ALL AREA WORK. 3.NO NEW DESIGN FEATURES OR ENGINEERING CHANGES ARE MADE UNDER THIS PERMIT. MECHANICAL AND ELECTRICAL DRAWINGS ARE BASED SOLELY ON THE SCOPE OF THE WORK TO BE PERFORMED; ALL WORK IS DIRECT REPLACEMENT OF EXISTING COMPONENTS. 4.ELECTRICAL CIRCUITS FOR THE ELEVATOR CAB LIGHTING, PIT LIGHTING, MACHINE ROOM (MR) LIGHTING AND MR GFCI CIRCUITS ARE ALL PRE-EXISTING CIRCUITS VERIFIED TO BE POWERED FROM SEPARATE SOURCES. REPLACEMENT OF THESE COMPONENTS AND FIXTURE ARE ALL DIRECT REPLACEMENT OF EXISTING EQUIPMENT; THE ONLY NEW CIRCUITS ADDED ARE AC MINI SPLIT IN THE MACHINE ROOM. 2800 North Highway A1A Fort Pierce, FL 34949 CS.1 - COVER SHEET E.0 - MR PANEL SCHEDULE E.1 - ELEVATOR MACHINE ROOM M.1 - ELEVATOR MACHINE ROOM 1.INSTALL NEW ELEVATOR MACHINE ROOM AIR CONDITIONER. 2.INSTALL NEW CIRCUITS FOR ELEVATOR MACHINE ROOM AC. 3.DIRECT REPLACEMENT OF ELEVATOR MAIN LINE DISCONNECTS. 4.DIRECT REPLACEMENT OF ELEVATOR CAB LIGHT DISCONNECTS. 5.DIRECT REPLACEMENT OF ALL NECESSARY LOAD SIDE CONDUIT AND WIRE FROM THE MAIN LINE POWER AND CAB LIGHT DISCONNECTS TO THE NEW ELEVATOR CONTROLLERS. 6.DIRECT REPLACEMENT OF LIGHT FIXTURES IN THE ELEVATOR MACHINE ROOM. 7.DIRECT REPLACEMENT OF EXISTING NON-GFCI OUTLET WITH GFCI RECEPTACLE IN THE ELEVATOR MACHINE ROOM. 8.DIRECT REPLACEMENT OF LIGHT FIXTURES IN THE ELEVATOR PITS. 9.DIRECT REPLACEMENT OF EXISTING NON-GFCI OUTLET WITH GFCI RECEPTACLE IN THE ELEVATOR PITS. 10.DIRECT REPLACEMENT OF EXISTING MOTOR OPERATED DAMPER IN HOISTWAY. 11.INSTALL NEW AUTOMATIC TRANSFER SWITCH. SCOPE OF WORK GENERAL NOTES DRAWING SCALE PROJECT NO. DRAWING NO. SHEET OF DATEDRAWN BY T H I S D O C U M E N T C O N T A I N S I N F O R M A T I O N T H A T C A N N O T B E R E P R O D U C E D O R D I V U L G E D , I N W H O L E O R I N P A R T , W I T H O U T W R I T T E N A U T H O R I Z A T I O N F R O M N I C H O L S C O N T R A C T I N G , I N C . 3 0 1 -9 2 4 -5 2 5 8 FREDERICK NICHOLS -CGC1522915 GREGORY JOHN GRESETH - EC13009689 GREGORY JOHN GRESETH - CAC1820514 5 0 8 O L N E Y S A N D Y S P R I N G R O A D S U I T E #2 0 0 S A N D Y S P R I N G , M D 2 0 8 6 0 PHONE:3 0 1 -9 2 4 -5 2 5 8 FAX:3 0 1 -9 2 4 -5 2 4 5 W W W .N I C H O L S C O N T R A C T I N G .C O M J.PaglinawanCONTRACT L I CENSE INFO R M A TIONLIST O F D R A W I N G S NO.BY REVISION DATE 1 2 3 SCOPE OF WORK GENERAL NOTES ARCH Full Bleed D (36.00 X 24.00 Inches) 12345678 F E D C B A 12345678 F E D C B A OCCUPANCY CLASSIFICATION TYPE OF CONSTRUCTION NO. OF STORIES APPLICABLE BUILDING CODES 01-20-21122 6242021 Barclay Beach Club 1 OF 5 CS.1 HOISTWAY RESIDENTIAL, GROUP R-2 TYPE IB 11 STORIES FBC 2020 - 7TH EDITION, NFPA 101, NFPA 90A, NFPA 70 - 2017 EDITION, NFPA 72 MACHINE ROOM (ROOF LEVEL) GENERATOR ROOM ENTRANCE (GROUND LEVEL) ELECTRICAL SYMBOL LEGENDS SHEET SYMBOL LEGENDS FIXTURE SCHEDULE AC UNIT 1-LINE DIAGRAM PANEL SCHEDULE VOLTAGE DROP DRAWING SCALE PROJECT NO. DRAWING NO. SHEET OF DATEDRAWN BY T H I S D O C U M E N T C O N T A I N S I N F O R M A T I O N T H A T C A N N O T B E R E P R O D U C E D O R D I V U L G E D , I N W H O L E O R I N P A R T , W I T H O U T W R I T T E N A U T H O R I Z A T I O N F R O M N I C H O L S C O N T R A C T I N G , I N C . 3 0 1 -9 2 4 -5 2 5 8 FREDERICK NICHOLS - CGC1522915 GREGORY JOHN GRESETH - EC13009689 GREGORY JOHN GRESETH - CAC1820514 5 0 8 O L N E Y S A N D Y S P R I N G R O A D S U I T E #2 0 0 S A N D Y S P R I N G , M D 2 0 8 6 0 PHONE:3 0 1 -9 2 4 -5 2 5 8 FAX:3 0 1 -9 2 4 -5 2 4 5 W W W .N I C H O L S C O N T R A C T I N G .C O M J.PaglinawanCONTRACT L I CENSE INFO R M A TIONSHEET C O N T E N T S NO.BY REVISION DATE 1 2 3 ARCH Full Bleed D (36.00 X 24.00 Inches) 12345678 F E D C B A 12345678 F E D C B A AS SHOWN VP ELEVATOR PIT 64 64 120 120 2X4 LED VAPORTIGHT LIGHT LITHONIA C232120RE FOUR BROTHERS C48232VP WHITE WHITE SURFACE MOUNT SURFACE MOUNT LOCATION WATTS VOLTS FIXTURE TYPE MODEL #FINISH COMMENTS G E N E R A L E L E C T R I C A L N O T E PLANS SUBMITTED FOR REVIEW AFTER DECEMBER 31, 2017 ARE DESIGNED IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRICAL CODE. FIXTURE SCHEDULE ELECTRICAL SYMBOL LEGEND MAGNETIC MOTOR STARTER COMBINATION MOTOR STARTER (480,0,20) = VOLTAGE, STARTER SIZE, FUSE AMPS MANUAL STARTER W/ OVERLOAD PROTECTION SURFACE JUNCTION BOX SURFACE JUNCTION BOX - WALL FLUSH JUNCTION BOX - CEILING FLUSH JUNCTION BOX - WALL FLUSH JUNCTION BOX - FLOOR MOTOR (# = HORSEPOWER) FIXED EQUIPMENT LOCATION NON FUSED DISCONNECT SWITCH (30 = AMP) FUSED DISCONNECT SWITCH (30/30 = AMP/FUSE) REVENUE METER, KWH/D CONDUIT UP, CONDUIT DOWN WIRING (480,0,20) $m J J J J J # F (30) (30/30) M DOOR SWITCH MOUNTING LOCATION:WALL 2-WAY SWITCH MOUNTING LOCATION:WALL 3-WAY SWITCH MOUNTING LOCATION:WALL $D $2 $3 TELEPHONE OUTLET SMOKE DETECTOR - CEILING HEAT DETECTOR - CEILING DUPLEX RECEPTACLE - GFCI QUAD RECEPTACLE - GFCI LED VAPORTIGHT LIGHT, 4' - T8 BULB, WHITE F F S H VP SHEET SYMBOL LEGEND LINE CONTINUE BREAK NEW WORK CONNECTION TO EXISTING WORK DETAIL REFERENCE TOP - DETAIL # BOTTOM - SHEET OF APPEARANCE # X0.0 SECTION REFERENCE TOP - DETAIL # BOTTOM - SHEET OF APPEARANCE # X0.0 #LOW VOLTAGE FEEDER DESIGNATOR ELEVATION DESIGNATION EQUIPMENT DESIGNATION# PLAN CONTINUATION DESIGNATION BOTTOM - SHEET OF CONTINUATIONX0.0 REFER REVISION ## 2 TON AC 1- LINE DIAGRAM PANEL SCHEDULE VOLTAGE DROP 2X4 LED VAPORTIGHT LIGHT LED VAPORTIGHT LIGHT, 4' - T8 BULB, WHITE 01-20-21122 6/24/2021 Barclay Beach CluE 2 OF 5 E0.1 Elevator Panel AC IDU (30) F (30/20) 3 #12 THWN + 12G in 1/2" Conduit 3 #12 THWN + 12G in 1/2" Conduit 2 # 12 THWN + 12G in 1/2" Conduit 2 # 12 THWN + 12G in 1/2" Conduit AC ODU Circuit 18 \ 19 F 2800 North Highway A1A Fort Pierce, FL 34949 GFCI $GFCI GFCIVP VP $GFCIVP VP $MACHINE ROOM ELECTRICAL ELEVATOR PIT ELECTRICAL 1.INSTALL NEW ELEVATOR MACHINE ROOM AIR CONDITIONER. 2.INSTALL NEW CIRCUITS FOR ELEVATOR MACHINE ROOM AC. 3.DIRECT REPLACEMENT OF ELEVATOR MAIN LINE DISCONNECTS. 4.DIRECT REPLACEMENT OF ELEVATOR CAB LIGHT DISCONNECTS. 5.DIRECT REPLACEMENT OF ALL NECESSARY LOAD SIDE CONDUIT AND WIRE FROM THE MAIN LINE POWER AND CAB LIGHT DISCONNECTS TO THE NEW ELEVATOR CONTROLLERS. 6.DIRECT REPLACEMENT OF LIGHT FIXTURES IN THE ELEVATOR MACHINE ROOM. 7.DIRECT REPLACEMENT OF EXISTING NON-GFCI OUTLET WITH GFCI RECEPTACLE IN THE ELEVATOR MACHINE ROOM. 8.DIRECT REPLACEMENT OF LIGHT FIXTURES IN THE ELEVATOR PITS. 9.DIRECT REPLACEMENT OF EXISTING NON-GFCI OUTLET WITH GFCI RECEPTACLE IN THE ELEVATOR PITS. 10.DIRECT REPLACEMENT OF EXISTING MOTOR OPERATED DAMPER IN HOISTWAY. 11.INSTALL NEW AUTOMATIC TRANSFER SWITCH. DRAWING SCALE PROJECT NO. DRAWING NO. SHEET OF DATEDRAWN BY T H I S D O C U M E N T C O N T A I N S I N F O R M A T I O N T H A T C A N N O T B E R E P R O D U C E D O R D I V U L G E D , I N W H O L E O R I N P A R T , W I T H O U T W R I T T E N A U T H O R I Z A T I O N F R O M N I C H O L S C O N T R A C T I N G , I N C . 3 0 1 -9 2 4 -5 2 5 8 FREDERICK NICHOLS - CGC1522915 GREGORY JOHN GRESETH - EC13009689 GREGORY JOHN GRESETH - CAC1820514 5 0 8 O L N E Y S A N D Y S P R I N G R O A D S U I T E #2 0 0 S A N D Y S P R I N G , M D 2 0 8 6 0 PHONE:3 0 1 -9 2 4 -5 2 5 8 FAX:3 0 1 -9 2 4 -5 2 4 5 W W W .N I C H O L S C O N T R A C T I N G .C O M J.PaglinawanCONTRACT L I CENSE INFO R M A TIONSHEET C O N T E N T S NO.BY REVISION DATE 1 2 3 ARCH Full Bleed D (36.00 X 24.00 Inches) 12345678 F E D C B A 12345678 F E D C B A G E N E R A L E L E C T R I C A L N O T E PLANS SUBMITTED FOR REVIEW AFTER DECEMBER 31, 2017 ARE DESIGNED IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRICAL CODE. DRAWINGS ARE PROVIDED TO REFERENCE LOCATIONS OF WORK SITES AND SURROUNDING AREAS. ALL MEASUREMENTS AND DISTANCES MUST BE VERIFIED AT THE WORK SITE. # NOTE CONSTRUCTION NOTES KEY PLAN 01-20-21122 6/24/2021 Barclay BeacN CluE 3 OF 5 E1.1 APPLICABLE BUILDING CODESAC IDUFeet 0 1.5 3 1/2" = 1' MACHINE ROOM- ELECTRICAL- GROUND LEVELA1 SCALE Feet 0 1.5 3 1/2" = 1' ELEVATOR PIT- ELECTRICAL- GROUND FLOORA2 SCALE AC CL FBC 2020 - 7TH EDITION, NFPA 101, NFPA 90A, NFPA 70 - 2017 EDITION, NFPA 72 2800 North Highway A1A Fort Pierce, FL 34949Feet 0 1.5 31/2" = 1' ELECTRICAL ROOM- GROUND FLOORA2 SCALE AC AC ODUCL ML ML ELEVATOR 1 MACHINE ELEVATOR 2 MACHINE CNTLR 1 CNTLR 2 ATS GENERATOR ATS 1 - LINE DIAGRAM 4 X 500 MCM + 3G THHN IN 3" C 4 X 500 MCM + 3G THHN IN 3" C NORMAL SOURCE GENERATOR 4 2 1 3 5 6 6 6 6 6 6 7 8 8 8 8 99 10 11 CL - 2 # 12 THHN + 12G 1 2" C ML - 3 # 3 THHN + 6G 1 1 4" C GFCI MACHINE ROOM MECHANICAL DRAWING SCALE PROJECT NO. DRAWING NO. SHEET OF DATEDRAWN BY T H I S D O C U M E N T C O N T A I N S I N F O R M A T I O N T H A T C A N N O T B E R E P R O D U C E D O R D I V U L G E D , I N W H O L E O R I N P A R T , W I T H O U T W R I T T E N A U T H O R I Z A T I O N F R O M N I C H O L S C O N T R A C T I N G , I N C . 3 0 1 -9 2 4 -5 2 5 8 5 0 8 O L N E Y S A N D Y S P R I N G R O A D S U I T E #2 0 0 S A N D Y S P R I N G , M D 2 0 8 6 0 PHONE:3 0 1 -9 2 4 -5 2 5 8 FAX:3 0 1 -9 2 4 -5 2 4 5 W W W .N I C H O L S C O N T R A C T I N G .C O M J.PaglinawanCONTRACT L I CENSE INFO R M A TIONSHEET C O N T E N T S NO.BY REVISION DATE 1 2 3 ANSI Expand B (11.00 X 17.00 Inches) 12345678 F E D C B A 12345678 F E D C B A DRAWINGS ARE PROVIDED TO REFERENCE LOCATIONS OF WORK SITES AND SURROUNDING AREAS. ALL MEASUREMENTS AND DISTANCES MUST BE VERIFIED AT THE WORK SITE. NOTE MECHANICAL NOTES DRAWING NOTES 1/2" = 1'-0" APPLICABLE BUILDING CODES NFPA 101 LIFE SAFE CODE 01-20-21122 6/24/2021 Barclay Beach Condo 4 OF 5 M1.1 ·THE CONDENSATE REMOVAL SYSTEM FOR THE INDOOR AC UNIT SHALL BE EQUIPPED WITH A WATER LEVEL MONITORING DEVICE THAT WILL SHUT OF THE EQUIPMENT SERVED IN THE EVENT THAT THE PRIMARY DRAIN BECOMES RESTRICTED (FBC M-307.2.3). ·THE CONDENSATE DRAIN LINE SHALL BE MADE OF POLYETHYLENE, ABS, CPVC OR PVC PIPE OR TUBING AND SHALL BE A MINIMUM ¾” INTERNAL DIAMETER AND NOT DECREASE IN SIZE FROM THE DRAIN PAN TO THE PLACE OF CONDENSATE DISPOSAL. IF A CONDENSATE PUMP IS NOT INSTALLED, THE LINE SHALL MAINTAIN A MINIMUM 1/8TH UNIT DOWNWARD SLOPE OVER ITS LENGTH (FBC 307.2.1). ·FASTEN THE CONDENSING UNIT TO WALL MOUNT BRACKET (FL PRE-APPROVED #18362.1) USING FOUR (4) M10, GRADE 80 BOLTS WITH LOCK WASHERS AND NUTS (FBC, MECHANICAL 301.13 AND FBC 1620). ·ALL THROUGH PENETRATIONS, RELATED TO THIS WORK, SHALL BE SEALED WITH FIRE RATED FOAM AND/OR MASONRY AND PROTECTED BY AN APPROVED PENETRATION FIRESTOP SYSTEM, USING INTUMESCENT MATERIALS, INSTALLED AS TESTED IAW WITH ASTM 814 OR UL 1479. ·THE CONDENSATE DRAIN SHALL TERMINATE IN THE CLOSEST PLACE THAT MEETS THE REQUIREMENTS AS AN APPROVED PLACE OF DISPOSAL (A GRASSY/DIRT/MULCHED AREA OR APPROVED DRAIN/DRAIN PIPE). CONDENSATE SHALL NOT DISCHARGE INTO A STREET, ALLEY OR OTHER AREAS SO AS TO CAUSE A NUISANCE. (FBC M-307.2). ·MINIMUM EFFICIENCY REQUIRED FOR PACKAGE UNIT AC AS PER FBC, ENERGY CONSERVATION C403.2.3 IS 14.0 SEER. ·MACHINE ROOM CONSTRUCTION IS POURED SLAB FLOOR, CMU WALLS AND POURED SLAB CEILING. DOOR IS HOLLOW METAL WITH THRESHOLD AND WEATHER-STRIPPING. EXISTING CONSTRUCTION IS IN ACCORDANCE WITH FBC, ENERGY EFFICIENCY C503.2 FREDERICK NICHOLS -CGC1522915 GREGORY JOHN GRESETH - EC13009689 GREGORY JOHN GRESETH - CAC1820514 CONFIGURATION A - 2 HR F RATINGS SECTION A-A SYSTEM NO. C-AJ-1014 F RATING – 2 HR T RATING – 0 HR L RATING AT AMBIENT – LESS THAN 1 CFM/SQ FT L RATING AT 400 F – LESS THAN 1 CFM/SQ FT A 2 A 4 4 2 1 3 1. FLOOR OR WALL ASSEMBLY – MIN 3-1/4 IN. (83 MM) THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600-2400 KG/M3) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS*. MAX DIAM OF CIRCULAR OPENING IS 6 IN. (152 MM). SEE CONCRETE BLOCK (CAZT) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS. 2. THROUGH PENETRANTS – ONE METALLIC PIPE OR CONDUIT TO BE CENTERED WITHIN THE FIRESTOP SYSTEM. A NOM ANNULAR SPACE OF 3/4 IN. (19 MM) IS REQUIRED WITHIN THE FIRESTOP SYSTEM. PIPE OR CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES OR CONDUITS MAY BE USED: A. STEEL PIPE – NOM 4 IN. DIAM (102 MM) (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. B. CONDUIT – NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR STEEL CONDUIT. 3. PACKING MATERIAL – MIN 4 PCF (64 KG/M3) MINERAL WOOL BATT INSULATION FIRMLY PACKED INTO OPENING AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL AS REQUIRE TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. MIN THICKNESS OF PACKING MATERIAL IN FLOORS AND WALLS TO BE 2-3/4 IN. (70 MM) AND 2-1/4 IN. (57 MM), RESPECTIVELY. 4. FILL, VOID OR CAVITY MATERIAL* – SEALANT – MIN 1/2 IN. (13 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH TOP SURFACE OF FLOOR OR WITH BOTH SURFACES OF WALL. AS AN ALTERNATE, THE PERMANENT FORMING MATERIAL (ITEM 3) MAY BE OMITTED IF THE FILL MATERIAL THICKNESS IS INCREASED TO A MIN 1-1/2 IN. (38 MM). 3M COMPANY – TYPES FB-1000 NS, FB-1003SL (FLOORS ONLY), FB-2000 OR FB-2000+. *BEARING THE UL CLASSIFICATION MARK "MACHINE ROOM" "OUTSIDE OF ROOF DECK" Feet 0 2.5 5 VOLTAGE DROP WALL PENETRATION NTSSCALE MACHINE ROOM- MECHANICAL-GROUND LEVELA1 NTSSCALE PENETRATION THRU WALLA1 1 ELEVATOR 1 NORTH AC IDUAC AC AC ODU2 WALL MOUNT BRACKET 2800 North Highway A1A Fort Pierce, FL 34949 ELEVATOR 2 NORTH MUZ-HM24NA MSZ-HM24NA MACHINE ROOM MECHANICAL DRAWING SCALE PROJECT NO. DRAWING NO. SHEET OF DATEDRAWN BY T H I S D O C U M E N T C O N T A I N S I N F O R M A T I O N T H A T C A N N O T B E R E P R O D U C E D O R D I V U L G E D , I N W H O L E O R I N P A R T , W I T H O U T W R I T T E N A U T H O R I Z A T I O N F R O M N I C H O L S C O N T R A C T I N G , I N C . 3 0 1 -9 2 4 -5 2 5 8 5 0 8 O L N E Y S A N D Y S P R I N G R O A D S U I T E #2 0 0 S A N D Y S P R I N G , M D 2 0 8 6 0 PHONE:3 0 1 -9 2 4 -5 2 5 8 FAX:3 0 1 -9 2 4 -5 2 4 5 W W W .N I C H O L S C O N T R A C T I N G .C O M J.PaglinawanCONTRACT L I CENSE INFO R M A TIONSHEET C O N T E N T S NO.BY REVISION DATE 1 2 3 ANSI Expand B (11.00 X 17.00 Inches) 12345678 F E D C B A 12345678 F E D C B A DRAWINGS ARE PROVIDED TO REFERENCE LOCATIONS OF WORK SITES AND SURROUNDING AREAS. ALL MEASUREMENTS AND DISTANCES MUST BE VERIFIED AT THE WORK SITE. NOTE MECHANICAL NOTES DRAWING NOTES ############ APPLICABLE BUILDING CODES NFPA 101 LIFE SAFE CODE 01-20-21122 6242021 Barclay Beach Condo 5 OF 5 M2.1 FREDERICK NICHOLS -CGC1522915 GREGORY JOHN GRESETH - EC13009689 GREGORY JOHN GRESETH - CAC1820514 Feet 0 2.5 5 VOLTAGE DROP WALL PENETRATION NTSSCALE TOP OF HOISTWAY- MECHANICAL-ROOF LEVELA1 2800 North Highway A1A Fort Pierce, FL 34949 ID #QTY.W (IN)H (IN)LOCATION 2-2 1 24.0 17.0 HOISTWAY TAG FREE AREA (ft2) FREE AREA (%) MAX WIND- LOAD (psf) SECT WIDE SECT HIGH SHIP SECT MULLION (IN) 1.10 39.0 200 1 1 3 STANDARD NOTE: DAMPER OPERATIONS *LOSS OF POWER - DAMPER SPRING OPERATED OPEN "PLAN VIEW" MOD (17"X24") LOCATION A ROOF LEVEL TOP OF HOISTWAY HOISTWAY MOD (17"X24") LOCATION 9' 1 1 "ROOF DECK" HOISTWAY HOISTWAY "SECTION VIEW" 1.DIRECT REPLACEMENT OF EXISTING MOTOR OPERATED DAMPER IN HOISTWAY.