HomeMy WebLinkAboutAPPROVED 5708 Tangelo Dr PSL Prop Duct DrawingJob #: 1587
Performed by Chris Bateman for:
Key Largo Spec Home (RHF)
5708 Tangelo Dr
Ft. Pierce, FL 34982
Air Calcs, LLC
7550 Hidden Hammock Ln
Vero Beach, FL 32966
Phone: 772.800.8413
vickilynne@aircalcs.com
Scale: 1 : 120
Page 1
Right-Suite® Universal 2021
21.0.08 RSU29066
2021-Nov-10 13:25:17
...ghtsoft HVAC\5708 Tangelo Dr.rup
N
Level 1
Garage
Laundry
Bed 2
Bath
Bath 2Hall
Bed 3Bed 4
Foyer GR
Pantry
Kitchen DR
Master Bath
Hers His
Master Bed
H/W
DUCTS IN THE GARAGE AND
DUCTS PENETRATING THE
WALLS OR CEILINGS
SEPARATING THE DWELLING
FROM
THE GARAGE SHALL BE
CONSTRUCTED OF A MINIMUM
NO.
26 GAGE (0.48 MM) SHEET
STEEL, 1 INCH MINIMUM RIGID
NONMETALLIC CLASS 0 OR
CLASS 1 DUCT BOARD, OR
OTHER APPROVED MATERIAL
AND SHALL HAVE NO
OPENINGS INTO THE GARAGE
100 CFM
6" Duct
6"Exhaust Vent
50 CFM
4" Duct
4"Exhaust Vent
50 CFM
4" Duct
4"Exhaust Vent
12 x 12
137 cfm
12 x 12
176 cfm
10 x 10
171 cfm
12 x 12
132 cfm
14 x 14
229 cfm
10 x 10
170 cfm
16 x 16
10 x 10
195 cfm 10 x 10
195 cfm
30 x 18
871 cfm
F
F
F
12 x 8
132 cfm
12 x 8
137 cfm
8 x 8
53 cfm
8 x 8
3 cfm
8 x 4
42 cfm
8 x 8
103 cfm
8 x 8
103 cfm
8 x 4
22 cfm
8 x 4
1 cfm
12 x 8
176 cfm
8 x 8
114 cfm
6 "
10 "
7 "
4 "
8 "
7 "
4 "
7 "
7 "
14 "
6 "
6 "
7 "7 "
4 "
18 "12 "4 "
6 "
14 "
7 "
6 "
9 "