Loading...
HomeMy WebLinkAboutAPPROVED 5708 Tangelo Dr PSL Prop Duct DrawingJob #: 1587 Performed by Chris Bateman for: Key Largo Spec Home (RHF) 5708 Tangelo Dr Ft. Pierce, FL 34982 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircalcs.com Scale: 1 : 120 Page 1 Right-Suite® Universal 2021 21.0.08 RSU29066 2021-Nov-10 13:25:17 ...ghtsoft HVAC\5708 Tangelo Dr.rup N Level 1 Garage Laundry Bed 2 Bath Bath 2Hall Bed 3Bed 4 Foyer GR Pantry Kitchen DR Master Bath Hers His Master Bed H/W DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL, 1 INCH MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE 100 CFM 6" Duct 6"Exhaust Vent 50 CFM 4" Duct 4"Exhaust Vent 50 CFM 4" Duct 4"Exhaust Vent 12 x 12 137 cfm 12 x 12 176 cfm 10 x 10 171 cfm 12 x 12 132 cfm 14 x 14 229 cfm 10 x 10 170 cfm 16 x 16 10 x 10 195 cfm 10 x 10 195 cfm 30 x 18 871 cfm F F F 12 x 8 132 cfm 12 x 8 137 cfm 8 x 8 53 cfm 8 x 8 3 cfm 8 x 4 42 cfm 8 x 8 103 cfm 8 x 8 103 cfm 8 x 4 22 cfm 8 x 4 1 cfm 12 x 8 176 cfm 8 x 8 114 cfm 6 " 10 " 7 " 4 " 8 " 7 " 4 " 7 " 7 " 14 " 6 " 6 " 7 "7 " 4 " 18 "12 "4 " 6 " 14 " 7 " 6 " 9 "