APPROVED AC Manual J
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-10 09:43:22 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW 1587Job:Load Short Form 8/9/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Key Largo Spec Home (RHF), Air Conditioning UnlimitedFor: 5708 Tangelo Dr, Fort Pierce, FL 34982 Design Information InfiltrationClgHtg SimplifiedMethod9041Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1529Design TD (°F) L-Daily range 5030Inside humidity (%) 572Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX16S361A AHRI ref Coil ASPT47D14A AHRI ref 201785534 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW7.9 Sensible cooling Btuh24500 Heating output Btuh27037 Latent cooling Btuh10500 Temperature rise °F21 Total cooling Btuh35000 Actual air flow cfm1167 Actual air flow cfm1167 Air flow factor cfm/Btuh0.046 Air flow factor cfm/Btuh0.053 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.76 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Laundry 36 425 819 20 43 Bed 2 136 2380 1636 110 86 Bath 42 58 38 3 2 Bath 2 51 760 501 35 26 Hall 30 0 0 0 0 Bed 3 153 3171 2434 147 128 Bed 4 157 2465 1703 114 90 Foyer GR 426 5173 5661 239 298 Pantry 14 0 0 0 0 Kitchen DR 411 4595 6071 213 320 Master Bath 95 2049 824 95 43 Hers 20 402 135 19 7 His 9 12 8 1 0 Master Bed 222 3716 2327 172 123 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-10 09:43:22 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 2 ...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW House 1801 25206 22156 1167 1167 Other equip loads 1769 939 Equip. @ 0.95 RSM 22033 Latent cooling 7228 TOTALS 1801 26975 29261 1167 1167 2021-Aug-10 09:43:22 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW 1587Job:Building Analysis 8/9/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Key Largo Spec Home (RHF), Air Conditioning UnlimitedFor: 5708 Tangelo Dr, Fort Pierce, FL 34982 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 17.246503.1Walls 14.0377717.4Glazing 000Doors 6.617851.0Ceilings 21.357343.23.2Floors 11.831842.2Infiltration 22.56076Ducts 00Piping 00Humidification 6.61769Ventilation0Adjustments 100.026975Total Cooling Walls Glazing Ceilings Infiltration Ducts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 12.428671.9Walls 20.6475822.0Glazing 000Doors 4.710960.6Ceilings 000Floors 3.98900.6Infiltration 29.46795Ducts 4.1939Ventilation 24.95750Internal gains 00Blower 0Adjustments 100.023095Total Latent Cooling Load = 7228 Btuh Overall U-value = 0.104 Btuh/ft²-°F Data entries checked. 2021-Aug-10 09:43:22 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW 1587Job:Component Constructions 8/9/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Key Largo Spec Home (RHF), Air Conditioning UnlimitedFor: 5708 Tangelo Dr, Fort Pierce, FL 34982 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Blk Wall, Stucco Ext, R-4.1 Ext Bd inI, 8" Thk, 1/2" Gyp Bd Int Fnsh 7913.155.10.109251ne 5062.02 7482.0211693.155.10.109371se 7802.0212203.155.10.109387sw 4592.027173.155.10.109228nw 24932.0238973.155.10.1091237all Partitions Frm Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"x4", 16" OC Stud 3741.467542.9411.00.101257 Windows Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht 103722.184118.000.62047ne Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 4.7 ft overhang (6.7 ft window ht, 1 ft sep.); 6.8 ft head ht 66116.567616.800.58040ne Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (2.17 ft window ht, 1 ft sep.); 6.8 ft head ht 9520.27916.800.5805sw Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht 68121.852516.800.58031sw 70622.652516.800.58031nw 138722.2105016.800.58062all Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 8 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht 21013.526216.800.58016sw 2021-Aug-10 09:43:22 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 2 ...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 8 ft overhang (6.7 ft window ht, 1 ft sep.); 6.8 ft head ht 56314.075818.800.65040sw Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (2.2 ft window ht, 1 ft sep.); 6.8 ft head ht 14922.611116.800.5807nw Doors (none) Ceilings Attic, Metal Roof, R-30 Ceil Ins, 1/2" Gyp Bd Int Fnsh 0.0341801 10960.6117850.9930.0 Floors On Grade Depth, Tile Flr Fnsh 00573428.700.989200 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-10 09:43:22 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW 1587Job:Project Summary 8/9/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Key Largo Spec Home (RHF), Air Conditioning UnlimitedFor:5708 Tangelo Dr, Fort Pierce, FL 34982 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh19130 Structure Btuh15361 Ducts Btuh6076 Ducts Btuh6795Central vent (56 cfm) 1769 Btuh Central vent (56 cfm) Btuh939 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh26975 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh22033 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh3032 Ducts Btuh2051Central vent (56 cfm) Btuh2145 CoolingHeating Outside air18011801Area (ft²) Equipment latent load Btuh7228 1577215772Volume (ft³)Air changes/hour 0.200.38 Equipment Total Load (Sen+Lat)Btuh29261 Equiv. AVF (cfm) 53100 Req. total capacity at 0.70 SHR ton2.6 Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg.Trade Trade GOODMAN Model Cond GSX16S361AAHRI ref Coil ASPT47D14A AHRI ref 201785534Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW7.9 Sensible cooling Btuh24500Heating output Btuh27037 Latent cooling Btuh10500 Temperature rise °F21 Total cooling Btuh35000Actual air flow cfm1167 Actual air flow cfm1167 Air flow factor cfm/Btuh0.046 Air flow factor cfm/Btuh0.053Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.76 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-10 09:43:22Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW 1587Job:Right-J® Worksheet 8/9/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name House Laundry 2 Exposed wall 199.9 ft 5.5 ft 3 Room height 8.8 ft 8.0 heat/coolft 4 Room dimensions ft6.5x5.5 5 Room area 1800.8 ft²35.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nene 3.153.15 2.022.02 338 251 791 506 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nene 17.9817.98 22.1522.15 47 0 841 1037 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 16.4516.45 40 0 676 661 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 sese 3.153.15 2.022.02 371 371 1169 748 0 0 0 0 11 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 swsw 3.153.15 2.022.02 479 387 1220 780 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 20.2120.21 5 1 79 95 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 21.8221.82 31 4 525 681 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 13.4813.48 16 16 262 210 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 swsw 18.8518.85 14.0214.02 40 40 758 563 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nwnw 3.153.15 2.022.02 266 228 717 459 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.6422.64 7 0 111 149 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.6422.64 31 0 525 706 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 257 257 754 374 44 44 129 64 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 1801 1801 1785 1096 36 36 35 22 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 1801 200 5734 0 36 6 158 0 6 c) AED excursion 655 -18 Envelope loss/gain 15946 8721 322 68 12 a) Infiltration 3184 890 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 5 1150 0 0 Appliances/other 4600 500 Subtotal (lines 6 to 13)19130 15361 322 568 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 19130 15361 322 568 15 Duct loads 32%44%6076 6795 32%44%102 251 Total room load 25206 22156 425 819 Air required (cfm)Air required (cfm)1167 1167 20 43 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-10 09:43:22Right-Suite® Universal 2021 21.0.08 RSU29066 Page 2...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW 1587Job:Right-J® Worksheet 8/9/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bed 2 Bath 2 Exposed wall 24.0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft135.8x1.0 ft6.0x7.0 5 Room area 135.8 ft²42.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nene 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nene 17.9817.98 22.1522.15 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 16.4516.45 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 sese 3.153.15 2.022.02 0 0 0 0 0 0 0 0 11 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 swsw 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 20.2120.21 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 21.8221.82 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 swsw 18.8518.85 14.0214.02 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nwnw 3.153.15 2.022.02 84 68 216 138 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.6422.64 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.6422.64 16 0 262 353 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 108 108 317 158 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 136 136 135 83 42 42 42 26 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 136 24 688 0 42 0 0 0 6 c) AED excursion 99 -1 Envelope loss/gain 1618 830 42 25 12 a) Infiltration 184 51 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 250 0 Subtotal (lines 6 to 13)1802 1131 42 25 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 4 3 2 1 14 Subtotal 1806 1134 44 26 15 Duct loads 32%44%574 502 32%44%14 12 Total room load 2380 1636 58 38 Air required (cfm)Air required (cfm)110 86 3 2 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-10 09:43:22Right-Suite® Universal 2021 21.0.08 RSU29066 Page 3...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW 1587Job:Right-J® Worksheet 8/9/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bath 2 Hall 2 Exposed wall 6.0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft6.0x8.5 ft8.5x3.5 5 Room area 51.0 ft²29.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nene 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nene 17.9817.98 22.1522.15 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 16.4516.45 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 sese 3.153.15 2.022.02 0 0 0 0 0 0 0 0 11 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 swsw 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 20.2120.21 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 21.8221.82 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 swsw 18.8518.85 14.0214.02 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nwnw 3.153.15 2.022.02 48 41 130 83 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.6422.64 7 0 111 149 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.6422.64 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 51 51 51 31 30 30 29 18 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 51 6 172 0 30 0 0 0 6 c) AED excursion 50 -1 Envelope loss/gain 464 314 29 18 12 a) Infiltration 105 29 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)569 343 29 18 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 7 4 -29 -18 14 Subtotal 577 348 0 0 15 Duct loads 32%44%183 154 32%44%0 0 Total room load 760 501 0 0 Air required (cfm)Air required (cfm)35 26 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-10 09:43:22Right-Suite® Universal 2021 21.0.08 RSU29066 Page 4...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW 1587Job:Right-J® Worksheet 8/9/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bed 3 Bed 4 2 Exposed wall 25.5 ft 21.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft153.3x1.0 ft157.0x1.0 5 Room area 153.3 ft²157.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nene 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nene 17.9817.98 22.1522.15 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 16.4516.45 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 sese 3.153.15 2.022.02 0 0 0 0 64 64 202 129 11 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 swsw 3.153.15 2.022.02 96 80 253 162 104 88 279 178 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 20.2120.21 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 21.8221.82 16 2 262 340 16 2 262 340 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 swsw 18.8518.85 14.0214.02 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nwnw 3.153.15 2.022.02 108 92 291 186 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.6422.64 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.6422.64 16 0 262 353 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 153 153 152 93 157 157 156 96 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 153 26 731 0 157 21 602 0 6 c) AED excursion 173 83 Envelope loss/gain 1953 1308 1501 826 12 a) Infiltration 447 125 368 103 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 250 250 Subtotal (lines 6 to 13)2399 1683 1869 1179 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 7 4 2 1 14 Subtotal 2407 1687 1871 1181 15 Duct loads 32%44%764 746 32%44%594 522 Total room load 3171 2434 2465 1703 Air required (cfm)Air required (cfm)147 128 114 90 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-10 09:43:22Right-Suite® Universal 2021 21.0.08 RSU29066 Page 5...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW 1587Job:Right-J® Worksheet 8/9/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Foyer GR Pantry 2 Exposed wall 34.5 ft 0 ft 3 Room height 9.5 heat/coolft 8.0 heat/coolft 4 Room dimensions ft426.3x1.0 ft5.5x2.5 5 Room area 426.3 ft²13.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nene 3.153.15 2.022.02 223 152 478 306 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nene 17.9817.98 22.1522.15 31 0 561 691 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 16.4516.45 40 0 676 661 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 sese 3.153.15 2.022.02 0 0 0 0 0 0 0 0 11 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 swsw 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 20.2120.21 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 21.8221.82 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 swsw 18.8518.85 14.0214.02 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nwnw 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.6422.64 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.6422.64 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 105 105 307 152 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 426 426 423 259 14 14 14 8 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 426 35 989 0 14 0 0 0 6 c) AED excursion -123 0 Envelope loss/gain 3435 1947 14 8 12 a) Infiltration 489 137 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 3 690 0 0 Appliances/other 1150 0 Subtotal (lines 6 to 13)3924 3923 14 8 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 2 1 -14 -8 14 Subtotal 3926 3925 0 0 15 Duct loads 32%44%1247 1736 32%44%0 0 Total room load 5173 5661 0 0 Air required (cfm)Air required (cfm)239 298 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-10 09:43:22Right-Suite® Universal 2021 21.0.08 RSU29066 Page 6...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW 1587Job:Right-J® Worksheet 8/9/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Kitchen DR Master Bath 2 Exposed wall 28.0 ft 19.5 ft 3 Room height 9.5 heat/coolft 8.0 heat/coolft 4 Room dimensions ft410.5x1.0 ft9.0x10.5 5 Room area 410.5 ft²94.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nene 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nene 17.9817.98 22.1522.15 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 16.4516.45 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 sese 3.153.15 2.022.02 71 71 224 144 72 72 227 145 11 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 swsw 3.153.15 2.022.02 195 139 438 280 84 79 250 160 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 20.2120.21 0 0 0 0 5 1 79 95 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 21.8221.82 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 13.4813.48 16 16 262 210 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 swsw 18.8518.85 14.0214.02 40 40 758 563 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nwnw 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.6422.64 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.6422.64 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 411 411 407 250 95 95 94 57 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 411 28 803 0 95 20 559 0 6 c) AED excursion 432 16 Envelope loss/gain 2892 1879 1209 473 12 a) Infiltration 583 163 342 96 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 1700 0 Subtotal (lines 6 to 13)3475 4202 1550 568 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 12 7 5 3 14 Subtotal 3487 4209 1555 571 15 Duct loads 32%44%1108 1862 32%44%494 253 Total room load 4595 6071 2049 824 Air required (cfm)Air required (cfm)213 320 95 43 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-10 09:43:22Right-Suite® Universal 2021 21.0.08 RSU29066 Page 7...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW 1587Job:Right-J® Worksheet 8/9/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Hers His 2 Exposed wall 4.0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft4.0x5.0 ft8.9x1.0 5 Room area 20.0 ft²8.9 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nene 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nene 17.9817.98 22.1522.15 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 16.4516.45 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 sese 3.153.15 2.022.02 32 32 101 64 0 0 0 0 11 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 swsw 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 20.2120.21 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 21.8221.82 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 swsw 18.8518.85 14.0214.02 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nwnw 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.6422.64 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.6422.64 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 20 20 20 12 9 9 9 5 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 20 4 115 0 9 0 0 0 6 c) AED excursion -3 0 Envelope loss/gain 235 74 9 5 12 a) Infiltration 70 20 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)305 93 9 5 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 305 93 9 5 15 Duct loads 32%44%97 41 32%44%3 2 Total room load 402 135 12 8 Air required (cfm)Air required (cfm)19 7 1 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-10 09:43:22Right-Suite® Universal 2021 21.0.08 RSU29066 Page 8...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW 1587Job:Right-J® Worksheet 8/9/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Master Bed 2 Exposed wall 31.9 ft 3 Room height 8.5 heat/coolft 4 Room dimensions ft222.4x1.0 5 Room area 222.4 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Blk Wall, Stucco Ext 0.109 ne 3.15 2.02 115 99 312 200 .G Impact, Clear Low-e 0.620 ne 17.98 22.15 16 0 280 346 .G Impact, Clear Low-e 0.580 ne 16.82 16.45 0 0 0 0 .W Blk Wall, Stucco Ext 0.109 se 3.15 2.02 132 132 415 266 11 W Blk Wall, Stucco Ext 0.109 sw 3.15 2.02 0 0 0 0 G Impact, Clear Low-e 0.580 sw 16.82 20.21 0 0 0 0 G Impact, Clear Low-e 0.580 sw 16.82 21.82 0 0 0 0 G Impact, Clear Low-e 0.580 sw 16.82 13.48 0 0 0 0 G Impact, Clear Low-e 0.650 sw 18.85 14.02 0 0 0 0 W Blk Wall, Stucco Ext 0.109 nw 3.15 2.02 26 26 80 51 G Impact, Clear Low-e 0.580 nw 16.82 22.64 0 0 0 0 G Impact, Clear Low-e 0.580 nw 16.82 22.64 0 0 0 0 P Frm Wall, 1/2" Gyp B 0.101 -2.94 1.46 0 0 0 0 C Attic, Metal Roof, R 0.034 -0.99 0.61 222 222 220 135 F On Grade Depth, Tile 0.989 -28.68 0.00 222 32 915 0 6 c) AED excursion -51 Envelope loss/gain 2224 947 12 a) Infiltration 596 167 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 500 Subtotal (lines 6 to 13)2820 1613 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2820 1613 15 Duct loads 32%44%896 714 Total room load 3716 2327 Air required (cfm)172 123 2021-Aug-10 09:43:22 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW 1587Job:Duct System Summary 8/9/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Key Largo Spec Home (RHF), Air Conditioning UnlimitedFor: 5708 Tangelo Dr, Fort Pierce, FL 34982 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.70in H2O0.70 Supply / return available pressure 0.541 / 0.159 in H2O in H2O0.541 / 0.159 Lowest friction rate in/100ft0.197in/100ft0.197 Actual air flow cfm1167cfm1167 Total effective length (TEL) ft355 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk 00VlFx0x0002338hBath st3120.025.5VlFx0x04.00.3723242760hBath 2 st195.012.2VlFx0x06.00.5051031322380hBed 2 st3120.029.1VlFx0x07.00.3631541763171hBed 3 st3120.024.4VlFx0x06.00.3751081372465hBed 4 st2100.032.6VlFx0x07.00.4081791442831cFoyer GR st2100.032.9VlFx0x07.00.4071791442831cFoyer GR-A st5200.048.9VlFx0x04.00.218922402hHers st5230.044.5VlFx0x04.00.1970112hHis st2100.032.6VlFx0x07.00.4081921283035cKitchen DR-A st2100.032.4VlFx0x07.00.4091921283035cKitchen DR-B st195.013.1VlFx0x04.00.5015224819cLaundry st5195.050.9VlFx0x06.00.220521142049hMaster Bath st5195.048.5VlFx0x06.00.222741031858hMaster Bed st5195.044.1VlFx0x06.00.226741031858hMaster Bed-A Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st5 Peak AVF 343 208 0.197 629 10.0 0x0 VinlFlx st2 st3 Peak AVF 355 293 0.363 804 9.0 0x0 VinlFlx st1 st1 Peak AVF 511 448 0.363 651 12.0 0x0 VinlFlx st2 Peak AVF 886 949 0.197 888 14.0 0x0 VinlFlx Bold/italic values have been manually overridden 2021-Aug-10 09:43:22 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 2 ...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb5 0x 1370 108 78.8 0.201 512 7.0 x0 0 VlFx rt1 rb6 0x 1760 154 80.4 0.197 505 8.0 x0 0 VlFx rt1 rb7 0x 1320 103 66.1 0.240 495 7.0 x0 0 VlFx rt1 rb1 0x 7250 879 66.8 0.237 498 18.0 x0 0 VlFx rt1 rb8 0x 2290 156 0 0 0 0 x0 0 VlFx Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 1171 1244 0.197 704 18.0 0x0 VinlFlx 2021-Aug-10 09:43:22 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...ts\Wrightsoft HVAC\5708 Tangelo Dr PSL Prop.rup Calc = MJ8 Front Door faces: SW 1587Job:Manual S Compliance Report 8/9/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Key Largo Spec Home (RHF), Air Conditioning UnlimitedFor: 5708 Tangelo Dr, Fort Pierce, FL 34982 Cooling Equipment Design Conditions °F76.8Entering coil DB:Btuh23095Sensible gain:°F90.4Outdoor design DB: °F64.0Entering coil WB:Btuh7228Latent gain:°F77.4Outdoor design WB: Btuh30323Total gain:°F75.0Indoor design DB: cfm1167Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: GSX16S361A+ASPT47D14AModel:Goodman Mfg.Manufacturer: cfm1167Actual airflow: % of load106Btuh24500Sensible capacity: % of load145Btuh10500Latent capacity: %70SHR:% of load115Btuh35000Total capacity: Heating Equipment Design Conditions °F68.1Entering coil DB:Btuh26975Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: Model:Manufacturer: cfm1167Actual airflow: °F50Temp. rise:% of load100kW7.9Output capacity: Meets all requirements of ACCA Manual S.