Loading...
HomeMy WebLinkAboutLETTER- RE-ROOFRECEIVED PAUL WELCH INC. JAN 2 6 2022 Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 �'p"°'iCmg Perrr�Itting Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 January 19, 2022 Re: Permit# 2112-0301 Re -Roof 606 S. Market St. Ft. Pierce, Florida To Whom It May Concern: Please allow approval of the shingle roof w/ Tamko asphalt shingles (FL# 35321.1) w/ 1 %" roofing nails (6 per tab) over Soprema Inc. peel and stick underlayment (FL# 2569.1) self -adhered to deck, drip edge and valley metals with 1 %" roofing nails at 4" o.c. over existing 19/32" cdx plywood sheathing w/ 8d ringshank nails at 4" o.c. at the above referenced address. Thank you for your attention to this matter. Since, ly: CAUL ELCH IN . Paul W Ich, P.E. Fla. Re . No. 29945 PW:ns I "'1 ,6�1 7`0,Z _ • J _ Planning & Development Services Department • Building &Code Regulations Division RECEIVED 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-15,RN 2 6 2022 Certification for Design Load Compliance St. Lucie county Permi#Inn Project Name: Project Address RE -ROOF 606 s. Market St. Permit #: INSTRUCTIONS FOR USE: Occupancy Type: B Construction Type: V • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (comolete all that a 1. DESIGN CODE: Florida Building Code 2020 7th Edition with 20 _Supplements using ASCE 7-16 2. Structure Designed as (check one): X Enclosed —Partially Enclosed _Open 3. Risk Category: _ I X II_ III_ IV Exposure Category: _ B X CD 4. Design Wind Velocity 165 mph 128 ASD N/A LRFD End Zone Width_ 5 ft S. Mean Roof Height: 20 ft Roof Pitch: N/A :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): 30.1 30.1 30.1 37.9 37.9 N/A Zone 1 Zone 2: Zone 3: Zone 4: Zone 5: Garage: -573 -91.3 -108.5 -41.1 -50.7 N/A 7. Design Loads: Floor: N/A PSF Roof/Dead: 7 PSF Roof/Live: 20 Balcony:. N/A PSF Dock N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED S. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certif that structural elements depicted on these plans provide adequate resistance to the design forces specified: Iy��'�� JI /1 '$'jl 1 Paul Welch P.E. 29945 / 5115 �' z7lzza Print Name Cert # & Co. Cent Auth. Paul Welch Inc. Signature, Date, and Seal SLCCDV Form # 020-12 Reviser) 3/15/12 (JS) 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL Company Name & Address