HomeMy WebLinkAboutENGINEER REPORTFDN Engineering, LLC
Date:
Project:
Address:
Push Pier Foundation Support System – Completion Report
FDN Engineering, LLC
2412 N 179th St.
Omaha, NE 68116
(402) 739-9642
January 27, 2022
Hart Residence
344 Palms Ave.
Fort Pierce, FL 34982
This report is prepared for Alpha Foundation Specialists (contractor) by FDN Engineering (engineer). Push
piers were installed at the above referenced project. The foundation support system is intended to stabilize
and potentially lift the existing foundation – reducing pressure on existing soils. The original design instructed
the contractor to install push piers, brackets, and all related components per the support manufacturer’s
installation instructions, technical manual, and according to the latest ICC-ES AC358, as well as industry
standards. See original engineering report for the design and details of the push pier support system. See
page 2 for the field logs provided by the contractor. See page 3 for a layout of the supports as identified by
contractor on the field log.
The installation of the supports was inspected; and the contractor has supplied engineer a log of the installed
locations, depth, and final drive & lift pressure of the push piers. Reference contractor’s field logs for more
information. Upon review, the installed supports conform to the original design and plans.
To the best of my professional knowledge, belief, and opinion, the design of the push pier support system
meets the structural requirements of the 2020 Florida Building Code, Seventh Edition to the extent that it
applies to our scope of work.
Page 1 of 3
FDN Engineering, LLC
The above information is the field logs provided by the contractor.
FDN Engineering, LLC
2412 N 179th St.
Omaha, NE 68116
(402) 739-9642
Chad A. Keller, P.E. on the date adjacent to the seal.
Printed copies of this document are not
considered signed and sealed and the signature
must be verified on any electronic copies.
January 27, 2022
This item has been digitally signed and sealed by
Page 2 of 3
DRAWING NOT TO SCALE
January 27, 2022
adjacent to the seal.
Printed copies of this document are not
considered signed and sealed and the signature
must be verified on any electronic copies.
Project:This item has been digitally signed and
FDN Engineering, LLC sealed by Chad A. Keller, P.E. on the date
Hart Residence 2412 N 179th St.
344 Palms Ave.Omaha, NE 68116
Fort Pierce, FL 34982 (402) 739-9642
Page 3 of 3
FOOTPRINT OF
RESIDENCE
1
2
3 4 5 6 7 8 9
10
11
12
GARAGE
Notes:
1. Shown below is the as-built layout of
supports per contractor's field log.