HomeMy WebLinkAbouthealth departmentSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
APPLICANT: Adams Homes of Northwest Florida, Inc
AGENT: Benjamin Drew"s Plumbing & Drain Services
PROPERTY ADDRESS: 5213 Birch Dr Fort Pierce, FL 34982
LOT: 37 BLOCK: 50
APPLICATION #:AP'1474250
PERMIT #:56-SF-2048882
DOCUMENT #:F11770545
DATE 2AID:03/18/2020
FEE PAID:545.00
RECEIPT #:56-PID-4343033
SUBDIVISION: Indian River Estates ID#: 3402-608-0385-000-1
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION
[ ] [01] TANK SIZE [1] 900.00 [21 225.00
[ ] [02] TANK MATERIAL Polypropylene
[ ] [031 OUTLET DEVICE
[ ] [04] MULTI -CHAMBERED [ L.2�j N ]
[ ] [051 OUTLET FILTER Polylok PL-68
[ ] [06] LEGEND 1. 70-156-90DC3 2. 70-156-02SC3
[ ] [071 WATERTIGHT
[ ] [081 LEVEL
[ ] [091 DEPTH TO LID
DRAINFIELD INSTALLATION
[ ] [101 AREA [1] 375 [21 SQFT
[ ] [111 DISTRIBUTION BOX HEADER X
[ ] [121 NUMBER OF DRAINLINES 1. 5.00 2.
[ ] [131 DRAINLINE SEPARATION
[ ] [141 DRAINLENE SLOPE
[ ] [15] DEPTH OF COVER
[ ] [161 ELEVATION [ ABOVE / BELOW ]BM 2.00
[ ] [171 SYSTEM LOCATION
[ ] [181 DOSING PUMPS 1.00
[ ] [19] AGGREGATE SIZE
[ ] [201 AGGREGATE EXCESSIVE FINES
[ ] [211 AGGREGATE DEPTH
FILL / EXCAVATION MATERIAL
[ ] (22] FILL AMOUNT
[ ] [231 FILL TEXTURE
[ ] (24] EXCAVATION DEPTH
[ ] [251 AREA REPLACED
[ ] [261 REPLACEMENT MATERIAL
Comments: Comments are on page 2.
SETBACKS
[ ] [271
SURFACE WATER
FT
[ ] [28]
DITCHES
FT
[ ] [291
PRIVATE WELLS
FT
[ ] [301
PUBLIC WELLS
FT
[ ] [31]
IRRIGATION WELLS 80
FT
[ ] [32]
POTABLE WATER 32
FT
[ ] [331
BUILDING FOUNDATIONS 6
FT
[ ] [341
PROPERTY LINES 11
FT
[ ] [351
OTHER
FT
FILLED / MOUND SYSTEM
[ ] [361
DRAINFIELD COVER
[ ] [37]
SHOULDERS
[ ] [381
SLOPES
[ ] [391
STABILIZATION
ADDITIONAL INFORMATION
[ ] [401
UNOBSTRUCTED AREA
[ ] [411
STORMWATER RUNOFF
[ ] [421
ALARMS
[ ] [431
MAINTENANCE AGREEMENT
[ ] [44]
BUILDING AREA
[ ] [451
LOCATION CONFORMS WITH SITE PLAN
[ ] [461
FINAL SITE GRADING
[ ] [471
CONTRACTOR (Reliable Septic & Services)
[ ] [481
OTHER INFILTRATOR ARC 24
ABANDONMENT
[ ] [491
TANK PUMPED
[ ] [501
TANK CRUSHED & FILLED
i
CONSTRUCTION [ APPROVED / St. Lucie CHD
DISAPPROVED Environmental ecialist a yi (Florida Department of He
FINAL SYSTEM [ APPROVED / DISAPPROVED ]: t.Lucie CHD
E ironmental Specialist I Ma e S V' i (Florida Department of H
(Explanation of Violations on following page)
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC
DATE: 01/14/9099
DATE: 01 /25/2022
Page 2 of 3
EH Database v 1.0.1 AP1474250 EID2048882
d>r'S�t
.e
,z ,ryr . STATE OF FLORIDA
DEPARTMENT OF HEALTH
'1r ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
,y CONSTRUCTION INSPECTION AND FINAL APPROVAL
,y6,'
Violation Number Comment
Comments
APPLICATION #:AP'1474250
PERMIT #:56-SF-2048882
DOCUMENT #:F11770545
DATE PAID:03/18/2020
FEE PAID:545.00
RECEIPT #:56-PID-4343033
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300
gpd.
New ST, DT, Llberty 1/3 hp pump, and 2x4+1x5+2x6 long BED DF installed. No violations, system ok to cover. Contractor
notified onsite. Needs final inspection for mound system, alarm and final site grading.
Final inspection conducted. Mound system checked, alarms checked, final site grading completed.
It was observed that the septic tank was uncovered for inlet connection and the inlet portion of the tank was damaged.
Photographs taken and contractor has been notified. Final inspection disapproved due to damage to septic tank. Re -inspection is
required.
Damaged septic tank replaced. No violations tank ok to cover. Contractor notified onsite. Needs final inspection for depth of cover,
mound system, and final site grading.
Final inspection conducted. Violations observed. Septic area was not completely sodded at time of inspection.
Needs re -inspection.
Final inspection completed. Mound system checked, depth of cover checked, and final site grading completed.
Final inspection approved. Emailed copy to building department and contractor.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1474250 EID2048882