HomeMy WebLinkAboutFL25574_R2_II_SS3500 FPA - REV BFLORIDA PRODUCT APPROVAL # 25574 GENERAL NOTES: SS-3500 IMPACT -RESISTANT STOREFRONT WINDOW SYSTEM GENERAL NOTES: 1. THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FBC, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 2. SHUTTERS ARE NOT REQUIRED PER FBC REQUIREMENTS, WHEN USED IN WIND-BORNE DEBRIS REGIONS. 3. GLAZING TYPE: SEE GLAZING DETAILS ON SHEET 15. 4. DESIGN PRESSURES: A) NEGATIVE DESIGN LOADS BASED ON STRUCTURAL & CYCLE TESTING AND GLASS PER ASTM E1300 B) POSITIVE DESIGN LOADS BASED ON WATER INFILTRATION, STRUCTURAL & CYCLE TESTING AND GLASS PER ASTM E1300 C) DESIGN LOADS ARE BASED ON ALLOWABLE STRESS DESIGN, ASD. 5. THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE. THE 33-1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD. 6. INSTALLATION SCREWS & FRAME CORNERS TO BE SEALED WITH NARROW JOINT SEALANT. 7. DISSIMILAR MATERIALS THAT COME INTO CONTACT, INCLUDING PRODUCT FRAMING, ANCHORAGE AND OPENING SUBSTRATES, SHALL BE COATED OR PROTECTED TO PREVENT CORROSIVE REACTIONS AS REQUIRED BY THE FLORIDA BUILDING CODE. 8. REFERENCES: ELCO ULTRACON & CRETEFLEX NOA'S, ITW TAPCON NOA; TEST REPORTS FTL-7137, 7208, 8717 & 17-7007 ANCHOR NOTES: 1. FOR CONCRETE/CMU SUBSTRATE APPLICATIONS IN MIAMI-DADE COUNTY, USE ONLY MIAMI-DADE COUNTY APPROVED ELCO ANCHORS. SEE TABLE 1 ON THIS SHEET FOR EMBEDMENT, EDGE DISTANCE AND SUBSTRATE REQUIREMENTS. 2. FOR SUBSTRATE APPLICATIONS SEE TABLE 1 ON THIS SHEET. 3. WOOD BUCKS DEPICTED AS 1X ARE LESS THAN 1-1/2" THICK. PROPERLY SECURED, 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE OR CMU. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD & TO BE REVIEWED BY THE BUILDING OFFICIAL. 4. SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE. USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. WOOD BUCKS, BY OTHERS, MUST BE SUFFICIENTLY ANCHORED TO RESIST LOADS IMPOSED ON THEM BY THE WINDOW. 5. METAL SUBSTRATE TO MEET MIN. STRENGTH AND THICKNESS REQUIREMENTS PER THE FBC AND TO BE REVIEWED BY THE AUTHORITY HAVING JURISDICTION. 6. IF SILL IS TIGHT TO SUBSTRATE, GROUT OR OTHER MATERIAL IS NOT REQUIRED. IF USED, NON -SHRINK, NON-METALLIC GROUT, MAX. 1/4" THICK & 3400 PSI MIN., (DONE BY OTHERS) MUST FULLY SUPPORT THE ENTIRE LENGTH OF THE SILL THAT IS NOT TIGHT TO THE SUBSTRATE, AND TRANSFER SHEAR LOAD TO SUBSTRATE. IF SUBSTRATE IS WOOD, 30# FELT PAPER OR MASTIC IS REQUIRED BETWEEN THE GROUT AND WOOD SUBSTRATE, OR AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. INSTRUCTIONS: 1. DETERMINE THE BUILDING'S REQUIRED DESIGN PRESSURE USING THE ASCE 7 STANDARD. THE PRODUCT'S DESIGN PRESSURE MUST MEET OR EXCEED THIS VALUE. 2. DETERMINE THE ANCHOR TYPE FROM TABLE 1, SHEET 1. 3. DETERMINE THE GLASS DESIGN PRESSURE FROM TABLE 2, SHEET 4. 4. JAMB ANCHOR SPACING IS GIVEN IN TABLES 5 & 6, SHEETS 7 & 8 AND HAVE BEEN CALCULATED FOR THE PRODUCT'S MAXIMUM DP. 5. MID -PANEL ANCHOR QUANTITIES ARE GIVEN IN TABLES 7 & 8, SHEETS 9 & 10 AND HAVE BEEN CALCULATED FOR THE PRODUCT'S MAXIMUM DP. 6. IF THE STOREFRONT WINDOW IS ATTACHED TO ANOTHER WINDOW THROUGH A COMMON MULLION: A) DETERMINE THE MULLION DESIGN PRESSURE FROM TABLE 9, SHEET 11. B) DETERMINE THE MAXIMUM DESIGN PRESSURE DUE TO MULLION CLUSTER ANCHORAGE FROM TABLES 3 OR 4, SHEETS 5-6 BASED ON YOUR SHIM SPACE, ANCHOR TYPE AND THE QUANTITY OF ANCHORS REQUIRED TO ATTAIN THE REQUIRED DESIGN PRESSURE. 7. THE LOWEST DESIGN PRESSURE FROM 3 & 6 ABOVE, SHALL BE USED FOR THE ENTIRE ASSEMBLY. 8. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. TABLE 1: Min. Edge Min. Min. O.C. Group Anchor Substrate Distance Embedment Distance #14 Steel or P.T. Southern Pine A 410 SS SMS (G5) (SG=0.55) 1" 1-3/8" 1" Aluminum, 6063-T5" #14 Steel or (0.125" min. thickness) 3/8" 1/8" 5/8" B 410 SS SMS (G5) Steel, A36" (0.125" min. thickness) 3/8" 1/8" 5/8" Concrete (min. 2.85 ksi) 2-1/2" 1-3/8" 3" Grout -Filled CMU, 1/4" Elco Ultracon (ASTM C-90) 2-1/2" 1-3/4" 4" Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" 6" Concrete (min. 3.00 ksi) 2-1/2" 1-3/4" 3" Concrete C 1/4" DeWalt (min. 3.00 ksi) 2-1/2" 1-3/8" 4" Ultracon+ Grout -Filled CMU, (ASTM C-90) 2-1/2" 1-3/4" 4" Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" 3" 1/4" Elco 410 S.S. Ungrouted CMU, CreteFlex (ASTM C-90) 2-1/2" 1-1/4" 6" Ungrouted CMU, 5/16" Elco Ultracon (ASTM C-90) 3-1/8" 1-1/4" 6" 1/4" Elco 410 Concrete S.S. CreteFlex (min. 3.35 ksi) 2-1/2" 1-3/4" 3" Concrete D (min. 3.52 ksi) 3-1/8" 2" 3" 5/16" Elco Ultracon Grout -Filled CMU, (ASTM C-90) 2-1/2" 2-1/4" 5" Concrete 3/8" Large Diameter (min. 3 ksi) 3" 1-1/2" 4" E ITW Tapcon Ungrouted CMU, (ASTM C-90) 3" 1-1/2" 6" * : No. 58705 �21 i 0, STATE OF /�SS/FZ ORID P. �0, ;Y 0NAL \� ��•. A. LYNN MILLER, P.E. P.E.# 58705 THIS SYSYTEM HAS BEEN TESTED TO MEET THE 400 FT -LB KINETIC ENERGY IMPACT LOADING REQUIREMENTS OF ANSI Z97.1. Revised By: Date: Comm . ® Architectural Products Revised By: Dote: CGI WINDOWS AND DOORS, INC. 10100 NW 25TH STREET MIAMI, FL 33172; (305) 593-6590 PREPARED BY: A. LYNN MILLER 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275; (941) 480-1600 COPYRIGHT © 2020 CGI WINDOWS & DOORS, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING. CERT. OF AUTH. #29296 IMPACT RATING RATED FOR LARGE & SMALL MISSILE IMPACT RESISTANCE * MIN. OF 3 THREADS BEYOND THE METAL SUBSTRATE. METAL SUBSTRATE TO MEET MIN. STRENGTH AND THICKNESS REQUIREMENTS PER CURRENT FLORIDA BUILDING CODE AND TO BE REVIEWED BY THE AUTHORITY HAVING JURISDICTION. FOR STEEL STUDS, MIN. FU=45 KSI & MIN. FY=33 KSI. "UNGROUTED CMU" VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. ALL ANCHOR HEAD TYPES ARE ALLOWED. CONTENTS: GENERAL NOTES, INSTRUCTIONS..........................................1 ANCHOR TYPES, TABLE 1.........................................................1 ELEVATIONS............................................................................... 2-3 GLASS DP, TABLE 2...................................................................4 MULLION ANCHOR CLUSTER DP - 1/4" SHIM, TABLE 3..........5 MULLION ANCHOR CLUSTER DP - 1/2" SHIM, TABLE 4..........6 JAMB ANCHOR SPACING - 1/4" SHIM, TABLE 5.......................7 JAMB ANCHOR SPACING - 1/2" SHIM, TABLE 6.......................8 MID -PANEL ANCHOR QUANTIY - 1/4" SHIM, TABLE 7.............9 MID -PANEL ANCHOR QUANTIY - 1/2" SHIM, TABLE 8.............10 VERTICAL MULLION & ANCHORLESS JAMB DP, TABLE 9.....11 HORIZ. SECTIONS.......................................................................12 VERT. SECTIONS........................................................................13 PTAC & WINDOW INSERT SECTIONS.......................................14 GLAZING & IG SPACER DETAILS..............................................15 EXTRUSION PROFILES..............................................................16 CORNER DETAILS......................................................................16 PARTS LIST, TABLE 10...............................................................16 Revision: REVISED CONTENTS TO INCLUDE ANCHORLESS JAMB TO TABLE 9 Revision: Description: I Jawn By: ROSOWSKI GENERAL NOTES �Title Date: STOREFRONT WINDOW SYSTEM DETAILS - LMI 03/23/16 Series/model: Scale: Street: Drawing No. Rev: SS-3500 NTS 1 OF 16 MD-3500-2-LM B SEE TABLES SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES SEE TABLES 7 3 & 4 FOR & 8 FOR 3 & 4 FOR & 8 FOR 3 & 4 FOR & 8 FOR CLUSTER MID -PANEL CLUSTER MID -PANEL CLUSTER MID -PANEL ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR QUANTITIES QUANTITY QUANTITIES QUANTITY QUANTITIES QUANTITY J I J I I I J I J J I I I I Jr_1 I I I 13 I I I I I I I I I I I / MIN 4" LENGTH OF 12-3/4 13 ANCHOR CHANNEL, OA PART #8, REQ. AT ALL � 1 1 ANCHOR LOCATIONS IN CURVED HEADER. REINFORCEMENT 1/4" NUT &BOLT, 24" FROM EACH END SEE TABLE 9 AND 24" MAX O.C. lik MULTIPLE HORIZONTAL N START 3-71 MULLIONS ALLOWED, r _ 60" MAX. LENGTH T SEE O.C. SPACING / ON TABLES 5 & 6 1 2 6" MAX. 3-7/8" MAX. � f 6" MAX. — f SEE TABLES 7 SEE TABLES &8FOR 3&4FOR MID -PANEL CLUSTER ANCHOR ANCHOR QUANTITY QUANTITIES NOTES: 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. SEE TABLES FOR MAXIMUM ALLOWED SIZES. 3. SEE SHEET 4 FOR DAYLIGHT OPENING (DLO) FORMULAS. H f13 SEE TABLES 7 SEE TABLES &8FOR 3&4FOR MID -PANEL CLUSTER ANCHOR ANCHOR QUANTITY QUANTITIES SEE STOREFRONT DOOR APPROVALFOR SPECIFICATIONS — --_�--— ----------------- E 12 I I I I I -r-------------- I --------------- ATTACHED I STOREFRONT DOOR & TRANSOM, SEE SEPARATE APPROVALFOR I SPECIFICATIONS I 1_- -=___ I I I I I I _-'_ __ _-I- =_ I t I --J L--------J f f L_ J � J-----J SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE & 8 FOR 3 & 4 FOR & 8 FOR STOREFRONT MID -PANEL CLUSTER MID -PANEL DOOR ANCHOR ANCHOR ANCHOR APPROVALFOR QUANTITY QUANTITIES QUANTITY SPECIFICATIONS TYP. ELEVATION OF STOREFRONT WINDOW SYSTEM WITH EXAMPLES OF CURVED HEADER, HORIZONTAL MULLION & STOREFRONT DOOR 144" MAX. FRAME HEIGHT (DOOR MAY LIMIT MAX HEIGHT, SEE SEPARATE APPROVAL) * ff No. l 48/1 Q� STA • 'Q[ C q/ON A. LYNN P P.EJ ill///, i8705 rc 1/21 'E OF AL `\\�� 1ILLER, P.E. 58705 AN 1 M FIR ANCHOR QUANTITY HALF OF OPTIONAL MULLION CLUSTER CHORLESS ANCHORS, TABLES JAMB 3 & 4 3-1/4" MAX � � 3- I II I II I II I II I II I II 1 I1 44" AX. AME rk� HEIGHT SEE TABLES 7 & 8 FOR MID -PANEL ANCHOR QUANTITY 6" MAX. - 7/8" MAX. - 1 - F � 11 �13 6" MAX. T OPTIONAL REINFORCEMENT SEE TABLE 9 A SEE O.C. SPACING ON TABLES 5 & 6 1 AIL_ _ F 3-1/4" MAX 3_ ANCHOR QUANTITY HALF OF MULLION CLUSTER ANCHORS, TABLES 3 & 4 NOTES: L 6" MAX. SEE TABLES SEE TABLES 7 SEE TABLES 3& 4 FOR & 8 FOR 3& 4 FOR CLUSTER MID -PANEL CLUSTER ANCHOR ANCHOR ANCHOR QUANTITIES QUANTITY QUANTITIES �PT/IIONAL REINFORCEMENT SEE TABLE 9 1/4" NUT & BOLT, 24" FROM EACH END AND 24" MAX O.C. REINFORCEMENT SEE TABLE 9 SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES &8FOR 3&4FOR &8FOR 3&4FOR MID -PANEL CLUSTER MID -PANEL CLUSTER ANCHOR ANCHOR ANCHOR ANCHOR SEE TABLES 7 QUANTITY QUANTITIES QUANTITY QUANTITIES & 8 FOR MID -PANEL N ANCHOR 1- 1---- 1 4 QUANTIITY --- 5 - ---1 ----- 1 I I I I I ATTACHED PTAC LOUVER, SEE SEPARATE APPROVALFOR SPECIFICATION; r- - -- - -I-- 4 r----------_-- 7/8" MAX. - i E 6" MAX. - SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES & 8 FOR 3 & 4 FOR & 8 FOR 3 & 4 FOR MID -PANEL CLUSTER MID -PANEL CLUSTER ANCHOR ANCHOR ANCHOR ANCHOR QUANTITY QUANTITIES QUANTITY QUANTITIES 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. SEE TABLES FOR MAXIMUM ALLOWED SIZES. 3. AWNING WINDOW INSERT SHOWN BUT MAY BE ANY APPROVED WINDOW WITH A FLANGED FRAME. 4. SEE SHEET 4 FOR DAYLIGHT OPENING (DLO) FORMULAS. 5. MULTIPLE INSERTS WITHIN THE SAME STOREFRONT WINDOW ALLOWED. III ATTACHED 14 WINDOW, SEE SEPARATE APPROVALFOR SPECIFICATIONS / 24" MAX. 1 � 6" MAX. SEE O.C. SPACING 12 ON TABLES 5 & 6 6" MAX. H 13 6" MAX. I I KNEEWALL BY OTHERS 6" MAX. 3-7/8" MAX. � � 4 SEE TABLES 7 SEE TABLES I SEE TABLES 7 SEE TABLES 3 & 4 FOR SEE TABLES 7 & 8 FOR 3 & 4 FOR & 8 FOR CLUSTER ANCHOR & 8 FOR MID -PANEL CLUSTER MID -PANEL QUANTITIES (SPLIT MID -PANEL ANCHOR ANCHOR ANCHOR BETWEEN ADJOINING ANCHOR QUANTITY QUANTITIES QUANTITY WINDOWS) QUANTITY TYP. ELEVATION OF STOREFRONT WINDOW SYSTEM WITH EXAMPLES OF WINDOW INSERT, PTAC INSERT, KNEEWALL. ANGLED HEADER. & ANCHORLESS JAMB * f No. 8/1 �r Q� STA • 'Q[ O A. LYNN P P. E.4 ill//// YNN,� �''% i8705 1/21 'E OF AL `>>\� TILLER, P.E. 58705 TARI F 9 Glass DP, (sf) & Maximum Size Centerline Width Frame Height DLO Width DLO Height Glass Type A & D Glass Type B, E & E1 Glass Type C, F & F1 24" 48" 20-1/4" 421/2" +90/-90 +70/-80 +90/-120 36" 32-1/4" +90/-90 +70/-80 +90/-120 48" 44-1/4" +90/-90 +70/-80 +90/-120 60" 56-1/4" +90/-90 +70/-80 +90/-120 72" 68-1/4" +90/-90 +70/-80 +90/-120 84" 80-1/4" +84.5/-84.5 +70/-80 +90/-120 96" 92-1/4" +80.5/-80.5 +70/-80 +90/-120 108" 104-1 /4" +90/-120 120" 116-1 /4" +90/-120 132" 128-1 /4" +90/-100 144" 140-1 /4" +90/-100 24" 60" 20-1/4" 54 1 /2" +90/-90 +70/-80 +90/-120 36" 32-1/4" +90/-90 +70/-80 +90/-120 48" 44-1/4" +90/-90 +70/-80 +90/-12 60" 56-1/4" +90/-90 +70/-80 +90/-12 72" 68-1/4" +82.8/-82.8 +70/-80 +90/-12 84" 80-1 /4" +90/-119.5 90" 86-1 /4" +90/-115.2 92" 88-1 /4" +90/-11 96" 92-1/4" +90/-111. 108" 104-1/4" +90/-100 120" 116-1/4" +90/-100 132" 128-1 /4" +60/-65 24" 72" 20-1/4" 66 1 /2" +90/-90 +70/-80 +90/-12 36" 32-1/4" +90/-90 +70/-80 +90/-12 48" 44-1/4" +90/-90 +70/-80 +90/-12 60" 56-1/4" +82.8/-82.8 +70/-80 +90/-12 72" 68-1 /4" +90/-12Q 84" 80-1 /4" +90/-100 96" 92-1/4" +90/-100 108" 104-1 /4" +60/-65 24" 78 20-1/4" 72-1/2" +90/-90 +70/-80 +90/-120 36" 32-1/4" +90/-90 +70/-80 +90/-12 48" 44-1/4" +87.2/-87.2 +70/-80 +90/-12 60" 56-1/4" +78.5/-78.5 +70/-78.5 +90/-120 70" 66-1 /4" +90/-119.4 72" 68-1/4" +90/-118.9 84" 80-1 /4" +90/-100 92" 88-1 /4" +90/-100 96" 92-1/4" +60/-65 102" 98-1 /4" +60/-65 24" 84" 20-1/4" 781/2" +90/-90 +70/-80 +90/-120 36" 32-1/4" +90/-90 +70/-80 +90/-120 48" 44-1/4" +84.5/-84.5 +70/-80 +90/-120 54" 50-1/4" +79.1/-79.1 +70/-79.1 +90/-120 60" 56-1/4" +90/-119.5 70" 66-1 /4" +90/-10 72" 68-1 /4" +90/-10 84" 80-1 /4" +90/-10 96" 92-1/4" +60/-65 24" 9o- 20-1/4" 841/2" +90/-90 +70/-80 +90/-12 36" 32-1/4" +90/-90 +70/-80 +90/-120 42" 38-1/4" +90/-90 +70/-80 +90/-120 48" 44-1/4" +82.3/-82.3 +70/-80 +90/-120 54" 50-1/4" +90/-120 60" 56-1 /4"' +90/-115.2 72" 68-1 /4" +90/-100 84" 1/4" +60/ 65 92" P-8-:11/4" +60/-65 Glass DP, (ps & Maximum Size Centerline Width Frame Height DLO Width DL Heigh t Glass Type A & D Glass Type B, E & E1 Glass Type C, F & F1 24" 97-3/4" 20-1/4" 92-14" +90/-90 +70/-80 +90/-120 36" 32-1/4" +90/-90 +70/-80 +90/-120 42" 38-1/4" +87.9/-87.9 +70/-80 +90/-120 48" 44-1/4" +80/-80 +70/-80 +90/-120 54" 50-1/4" +90/-117.9 70" 66-1/4" +90/-100 72" 68-1 /4" +90/-98.9 84" 80-1 /4" +60/-65 24" 102" 20-1/4" 96-12" +90/-90 +70/-80 +90/-120 30" 26-1/4" +90/-90 +70/-80 +90/-120 36" 32-1/4" +90/-90 +70/-80 +90/-120 42" 38-1/4" +86.9/-86.9 +70/-80 +90/-120 48" 44-1/4" +90/-120 54" 50-1/4" +90/-116.1 60" 56-1/4" +90/-100 70" 66-1/4" +90/-97.9 72" 68-1 /4" +60/-65 24" 108" 20-1/4" 102-12" +90/-90 +70/-80 +90/-120 30" 26-1/4" +90/-90 +70/-80 +90/-120 36" 32-1/4" +90/-90 +70/-80 +90/-120 42" 38-1/4" +85.6/-85.6 +70/-80 +90/-120 48" 44-1/4" +90/-120 60" 56-1/4" +90/-100 72" 68-1 /4" +60/-65 24" 114" 20-1/4" 108-1 /2" +90/-90 +70/-80 +90/-120 30" 26-1/4" +90/-90 +70/-80 +90/-120 36" 32-1/4" +90/-90 +70/-80 +90/-120 48" 44-1/4" +90/-120 60" 56-1/4" +90/-100 72" 68-1 /4" +60/-65 24" 120" 20-1/4" 114-1 /2" +90/-90 +70/-80 +90/-120 30" 26-1/4" +90/-90 +70/-80 +90/-120 36" 32-1/4" +90/-90 +70/-80 +90/-120 46.25" 42-1/2" +90/-120 48" 44-1/4" +90/-120 60" 56-1/4" +90/-100 24" 126" 20-1/4" 120-1/2" +90/-90 +70/-80 +90/-120 30" 26-1/4" +90/-90 +70/-80 +90/-120 36" 32-1/4" +90/-90 +70/-80 +90/-120 42" 38-1/4" +90/-120 48" 44-1/4" +90/-100 54" 50-1/4" +90/-100 60" 56-1/4" +60/-65 24" 132" 20-1/4" 126-12" +90/-90 +70/-80 +90/-120 30" 26-1M4' +90/-90 +70/-80 +90/-120 36" 32-1/4" +90/-120 42" 38-1/4" +90/-120 48" 44-1/4" +90/-100 54" 50-1/4" +90/-100 60" 56-1 /4" +60/-65 24" 138" 20-1/4" 132-1/2" +90/-90 +70/-80 +90/-120 30" 26-1/4" +90/-90 +70/-80 +90/-120 36" 32-1/4" +90/-120 42" 38-1/4" +90/-100 48" 44-1/4" +90/-100 60" 56-1 /4" +60/-65 24" 144" 20-1/4" 138-1/2" +90/-90 +70/-80 +90/-120 30" 26-1/4" +90/-90 +70/-80 +90/-120 36" 32-1/4" +90/-120 42" 38-1/4" +90/-100 48" 44-1/4" +90/-100 58.25" 54-1 /2" +60/-65 Glass Types A Lami: 1/4"A, .090" SG, 1/4"A B Lami: 1/4"HS, .090" PVB, 1/4"HS C Lami: 1/4"HS, .090" SG, 1/4"HS D Lami IG: 1/4"A, .090" SG, 1/4"A, AIRSPACE, 1/4"T CAP E Lami IG: 1/4"HS, .090" PVB, 1/4"HS, AIRSPACE, 1/4"T CAP E1 Reversed Lami IG: 1/4"HS, .090" PVB, 1/4"HS, AIRSPACE, 1/4"TCAP F Lami IG: 1/4"HS, .090" SG, 1/4"HS, AIRSPACE, 1/4"T CAP F1 Reversed Lami IG: 1/4"HS, .090" SG, 1/4"HS, AIRSPACE, 1/4"T CAP SLL SHLL 1 1 b FUK FULL GLASS UESGKIP I TUNS. CE IIEDTH NE CE WIDTH NE `W 1 FRAME HEIGHT DLO WIDTH DLO WIDTH i CENTERLINE DLO DLO HEIGHT HEIGHT HEIGHT / FRAME HEIGHT 1-3/4" DLO WIDTH FRAME HEIGHT DLO HEIGHT CENTERLINE / HEIGHT FRAME WIDTH FRAME WIDTH 1-3/4" DLO (DAYLIGHT OPENING) FORMULAS: FRAME WIDTH - 5-1/2" = DLO WIDTH FRAME HEIGHT - 5-1/2" = DLO HEIGHT CENTERLINE WIDTH - 3-3/4" = DLO WIDTH CENTERLINE HEIGHT - 3-3/4" = DLO HEIGHT CENTERLINE WIDTH - 2-1/4" = GLASS WIDTH CENTERLINE HEIGHT - 2-1/4" = GLASS HEIGHT FRAME WIDTH - 4" = GLASS WIDTH FRAME HEIGHT - 4" = GLASS HEIGHT NOTES: 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. DLO = DAYLIGHT OPENING 3. SEE SHEET 15 FOR DESCRIPTIONS OF GLASS TYPES. l Z c3 U .,.41 v' z Vo Ui vI- 0, I« p +• z N Ula 3: ® Q N J 0 z Z LL C a� 0 0 m U Z Y Z J N U)Z? No°� Z Q w p W W X Za i apa U3:L)0 }O -jLI m 0LL aoocn I w= L I O) z F a I �WU �_no aF- U Wo> U a. \\\\\II * No.. -vl48/1 STA 111 A. LYNN I P.E.I r2 N W J m 0 W U) W uogdu�saQ 'nay CO Y T j M N_ O cy') U) O C aaoC J � � J �e J N UMOJQ a O O W L0 C W I— 'ON U) DMa LL O O > Q Z F- 7 Z V n L k O 7/07 N LL O L J LLJ 0 0 U) YN)V4j'''�. i :NSF i8705 k = 1/21 'E OF 4(/ RID11100 P. •�G��� 11LLER, P.E. 58705 TABLE 3: ead/Sill, (+/- psf) ShimThickness: 1/4" Mullion Anchor Cluster Design Pressure at Head/Sill, Thickness: 1/4" m AVERAGE CENTERLINE + CENTERLINE CENTERLINE = WIDTH 1 WIDTH 2 WIDTH 2 M CL J CENTERLINE m CENTERLINE WIDTH 2 Q WIDTH 1 0 LLJ U) / LU ry- FRAME uoi duasaQ nay HEIGHT / Cfl / Y j M N 0 O O aaoa SILL SHOWN, HEAD 0 2 SIMILAR, ANCHOR J QUANTITY MAY VARY (n i (8 SHOWN) Xe J N uM°aa O � O 'I3 i W u7 C.qI= U M ? Vio WINDOW WINDOW vl- o w W ^ I o w 'ON �~ 2-1/4" Iz a U) U) DMa O ' cn = S��ABLE1,SHEE-rlTU Q ch rn FOR ANCHOR MIN. O.C. ® O N M L SPACING, 4" MAX. z Z LL o � - O p v o � V HEAD &SILL o Z } -57 C, ANCHOR PATTERN z Y c� w o w cli N o r . z z 0,, M p � 2 � O a oas r ° f; °� 0 a = ¢ rn w a M O r o o -j ° U- W W OLr) 00 z " a °_ ° `� ° LIJ Ozww m M w w V f o it 0 w 1-- w 0 C/7 NOTES: a o > (n a z a �ll ssaQ sauas 1. A COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE ��� �� NY .. \� �� APPROVAL, \ i� (STOREFRONT\,\CENSF ENTRANCE DOOR, PTAC LOUVER OR WINDOW No. 58705 INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY 8/1 1 /21 ;• �` ASSEMBLY OR THE 0 STATE OF STOREFRONT WINDOW T F SHALL BE THE DESIGN '•. [ORIDP,•' i PRESSURE OR THE ���ss/0NAL `�`\ ENTIRE / / / 1 1 1 1 \ \ \ A. LYNN MILLER, P.E. P.E.# 58705 Mullion Anchor Cluster Design Pressure at (+/- psf) Shim Average Centerline Width Fame Hight Group Anchor "A" Quantity Group Anchor "B" Quantity Group Anchor "C" Quantity Group Anchor "D" Quantity Anchor Group "E" Quantity Average Centerline Width Frame Height Group Anchor "A" Quantity Group Anchor "B" Quantity Group Anchor "C' Quantity Group Anchor "D" Quantity Group Anchor "E" Quantity 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 24" 1 1 8" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0120.0 24" 97-3/4" 120.0120.0120.0120.0120.0120.0120.0120.0 20.0120.0120.0120.0120.0120.0120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 36" 118.5 120.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 42" 105.5 120.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 48" 96.1 120.0120.0120.0120.0120.0120.0120.0 20.0120.0120.0120.0120.0120.0120.0 72" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 54" 89.0 120.0 120.0 120.0 120.0 120.0 119.1 120.0 20.0120.0120.0120.0120.0120.0120.0 84" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0,120.0 120.0,120.0 120. 120.0 120.0 70" 77.4 1 6.2 120.0 107.2 120.0 120.0,103.6 120.0 20.0120.0120.0120.0120.0120.0120.0 96" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 72" 76.5 1 4.8120.0105.9120.0120.0102.3120.0 20.0120.0120.0120.0120.0120.0120.0 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 84" 72.6 109.0 120.0 100.6 120.0 120.0 97.2 120.0 20.0 114.9 120.0 120.0 120.0 120.0 120.0 120" 120.0120.0120.0120.0120.0120.0120.0120.0120.0120.0120.0120.0120. 120.0 120.0 24" 102" 120.0 10.0120.0120.0120.0120.0120.0120.0 20.0120.0120.0120.0120.0120.0120.0 132" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 30" 120.0 1 0.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 144" 120.01120.0 120.0 120..0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.. 1120.0 120.0 36" 112.5 10.0120.0120.0120.0120.0120.0120.0 20.0120.0120.0120.0120.0120.0120.0 24" 0„ 120.0120.0120.0120.0120.0120.0120.0120.0120.0120.0120.0120.0120. 120.0 120.0 42" 100.01 0.0120.0120.0120.0120.0120.0120.0 20.0120.0120.0120.0120.0120.0120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 48" 90.9 1 0.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0120.0120.0120.0120.0120.0120.0 48" 120.0 120.0 120.01120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 1.20.0 120. 120.0 120.0 54" 84.0 1 0.0 120.0 116.3 120.0 120.0 112.4 120.0 20.0120.0120.0120.0120.0120.0120.0 60" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 60" 78.7 1 8.1 120.0 109.6 120.0 120.0 105.31120.0 20.01120.0 120.0 120.0 120.0 120.0 120.0 72" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 70" 72.5 1 8.8 120.0 100.4 120.0 120.0 97.0 120.0 20.0 114.7 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 72" 71.6 1 7.4 120.0 99.1 120.0 120.0 95.8 120.0 20.0 113.2 120.0 120.0 119.5 120.0 120.0 90" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 24" 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 92" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 96" 120.0120.0120.0120.0120.0120.0120.0120.0120.0120.0120.0120.0120. 120.0120.0 36" 105.0120.0120.0120.0120.0120.0120.0120.0 20.0120.0120.0120.0120.0120.0120.0 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 42" 93.1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 120" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 48" 84.4 120.0 120.0 116.8 120.0 120.0 112.91120.0 20.0,120.0 120.0 120.0 120.0 120.0 120.0 132" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 60" 72.7 109.0 120.0 100.7 120.0 120.0 97.2 120.0 20.0 115.0 120.0 120.0 120.0 120.0 120.0 24" 2„ 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 72" 65.6 98.4 120.0 90.9 120.0 120.0 87.8 120.0 20.0 103.8 120.0 120.0 109.6 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 24" 114" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 30" 114.5 120.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 36" 98.4 1 0.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0�I 72" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 48" 78.7 118.1 120.0 109.0 120.0 120.0 105.3 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 60" 67.5 101.2 120.0 93.5 120.0 120.0 90.3 120.0 20.0 106.7 120.0 120.0 112.7 120.0 120.0 96" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 72" 60.6 9 .9 120.0 83.9 120.0 120.0 81.0 120.0 20.0 95.8 120.0 120.0 101.1 120.0 120.0 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 24" 120" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 24" 8" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 30" 108.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 36" 92.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 46.25" 81.8 120.0 120.0 113.3 120.0 120.0 109.4 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 118.1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 48" 73.8 110.7 120.0 102.2 120.0 120.0 98.8 120.0 20.0 116.8 120.0 120.0 120.0 120.0 120.0 70" 113.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 60" 63.0 9,4.5 120.0 87.2 120.0 120.0 84.3 120.0 20.0 99.6 120.0 120.0 105.2 120.0 120.0 72" 112.51120.0 120.0 120.0 120.0 120.0 120.0 120.01120.0 120.0 120.0 120.0 120. 120.0120.0 24" 126" 120.0 10.0120.0120.0120.0120.0120.0120.0 20.0120.0120.0120.0120.0120.0120.0 84" 111.8 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 30" 102.2 1 0.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 92" 111.8 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 36" 87.5 1 0.0 120.0 120.0 120.0 120.0 117.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 96" 111.8 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 42" 77.1 115.7 120.0 106.8 120.0 120.0 103.2 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 102" 111.8 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 48" 69.5 104.2 120.0 96.2 120.0 120.0 92.9 120.0 20.0 109.9 120.0 120.0 116.0 120.0 120.0 24" 4" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 54" 63.6 95.5 120.0 88.1 120.0 120.0 85.1 120.0 20.0 100.6 120.0 120.0 106.2 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 60" 59.1 88.6 118.1 81.8 120.0 120.0 79.0 118.5 20.0 93.4 120.0 120.0 98.6 120.0 120.0 48" 118.1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 24" 132" 118.1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 110.5 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 30" 96.9 120.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 105.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 36" 82.9 120.0 120.0 114.8 120.0 120.0 110.9 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 70" 99.2 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 42" 73.0 109.5 120.0 101.0 120.0 120.0 97.6 120.0 20.0 115.4 120.0 120.0 120.0 120.0 120.0 72" 98.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 48" 65.6 98.4 120.0 90.9 120.0 120.0 87.8 120.0 20.0 103.8 120.0 120.0 109.E 120.0 120.0 84" 96.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 54" 60.0 9 .0 120.0 83.1 120.0 120.0 80.3 120.0 20.0 94.9 120.0 120.0 100.2 120.0 120.0 96" 96.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 60" 55.6 80.4 111.2 77.0 115.5 120.0 74.4 111.5 20.0 87.9 120.0 120.0 92.8 120.0 120.0 24" 1 0" 120.0 120.0 120.0 120.0 120.0 120.01120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 24" 138" 112.5 10.0120.0120.0120.0120.0120.0120.0 '20.01120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 30" 92.2 1 0.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 117.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 36" 78.7 1 8.1 120.0 109.0 120.0 120.0 105.3 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 107.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 42" 69.2 103.8 120.0 95.9 120.0 120.0 92.6 120.0 20.0 109.5 120.0 120.0 115.6 120.0 120.0 54" 100.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 48" 62.2 93.3 120.0 86.1 120.0 120.0 83.2 120.0 20.0 98.3 120.0 120.0 103.8 120.0 120.0 60" 94.5 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 60" 52.5 7 .7 105.0 72.7 109.0 120.0 70.2 105.3 20.0 83.0 120.0 120.0 87.6 120.0 120.0 72" 87.5 120.0 120.0 120.0 120.0 120.0 117.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 24" 144 107.4 1 0.0 120.0 120.0 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 84" 84.4 120.0 120.0 116.8 120.0 120.0 112.9 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 30" 87.9 1 0.0 120.0 120.0 120.0 120.0 117.6 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 92" 84.0 120.0,120.01116.3.120.0 120.OL1 12.4 120.01120.0 120.0 120.0 120.0 120. 120.0120.0 36" 75.0 1 103.8 120.0 120.0 100.3 120.0 '20.0 118.6 120.0 120. 120.0 120.0 42„ 65.9 98.8 120.0 91.2 120.0 120.0 88.1 120.0 o20.O 104.1 120.0 120.0 109.9 120.0 120.0 48" 59.1 8 .6 118.1 81.8 120.0 120.0 79.0 118.5 20.0 93.4 120.0 120.0 98.6 1120.01120.0 58.25" 50.8 7 .3 101.7 70.4 105.E 120.0 68.0 102.0 20.0 80.4 120.0 120.0 84.9 120.0 120.0 TABLE 4: Design Pressure at Head/Sill, (+/- Shim Thickness: 1/2" m AVERAGE CENTERLINE +CENTERLINE CENTERLINE = WIDTH 1 WIDTH 2 WIDTH 2 CENTERLINE J m CENTERLINE WIDTH 2 Q WIDTH 1 0 LU ry- FRAME uoi duasaQ nay HEIGHT / CO / Y j M N 0 O O aa°a SILL SHOWN, HEAD 0 J SIMILAR, ANCHOR QUANTITY MAY VARY (n J (8 SHOWN) �e J N uM°aa O � O 'I3 i W u7 Cd' I c� U M z ' V o WINDOW WINDOW w vl- ) w W I o 'ON �~ 2-1/4" Iz a � �Ma OI ( , � cn F � o � CO SEE TABLE R SHEET 1 v I Q 0 N M L FOR ANCHOR MIN. O.C. ® O Co SPACING, 4" MAX. z Z LL o O Q C) o V 0 CO HEAD &SILL o z }aays to �j ANCHOR PATTERN z Y c� w ow c ¢ z w N U) O r- rn ~ Z z � rn O Oo w 2 7l°aS 0 `1: 06 a _ ¢ rn w D O r o o -j ° U- W W O� 00 z " o ° o w o 0 oz_ww m 01- M w w o U � z o Q w c w Cn NOTES: wow (n a z a �ll ssaQ sauas 1. A COMBINED WITH ANOTHER ASSEMBLY ``�\\\ WITH A SEPARATE �� NY NNtij APPROVAL, \ i� (STOREFRONT \,\CENSF ENTRANCE DOOR, PTAC LOUVER OR WINDOW No. 58705 INSERT) THE LESSER _ * : = DESIGN PRESSURE VALUE OF ANY 8/1 1 /21 ;• �` ASSEMBLY OR THE STATE OF STOREFRONT WINDOW T ' F SHALL BE THE DESIGN PRESSURE OR THE ���ss/0NAL A. LYNN MILLER, P.E. P.E.# 58705 Mullio Anchor Cluster Design Pressure at Head/Sill, (+/- psf) Shim hickness: 1/2" Mullion Anchor Cluster psf) Average Centerline Width Fame Hight Group Anchor "A" Quantity Group Anchor "B" Quantity Group Anchor "C" Quantity Group Anchor "D" Quantity Anchor 3roup "E" Quantity Average Centerline Width Frame Height Group Anchor "A" Quantity Group Anchor "B" Quantity Group Anchor "C' Quantity Group Anchor "D" Quantity Group Anchor "E" Quantity 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 24" 1 8" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0120.0 24" 97-3/4" 106.71 0.0120.0106.7120.0120.0120.0120.0 20.0120.0120.0120.0120.0120.0120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 36" 76.5 114.7 120.0 76.5 114.7 120.0 104.6 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 42" 68.1 1(2.2 120.0 68.1 102.2 120.0 93.2 120.0 20.0 118.7 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 48" 62.0 930 120.0 62.0 93.0 120.0 84.8 120.0 20.0 108.1 120.0 120.0 120.0 120.0 120.0 72" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 54" 57.5 83.2 114.9 57.5 86.2 114.9 78.6 117.9 20.0 100.2 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 70" 50.0 73.0 100.0 50.0 75.0 100.0 68.4 102.5 20.0 87.1 120.0 120.0 120.0 120.0 120.0 96" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 72" 49.4 74.1 98.8 49.4 74.1 98.8 67.5 101.3 20.0 86.1 120.0 120.0 120.0 120.0 120.0 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 84" 46.9 7).3 93.8 46.9 70.3 93.8 64.1 96.2 20.0 81.7 120.0 120.0 120.0 120.0 120.0 120" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 24" 102" 101.7 1 0.0120.0101.7120.0120.0120.0120.0 20.0120.0120.0120.0120.0120.0120.0 132" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 30" 84.1 1 0.0 120.0 84.1 120.0 120.0 115.1 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 144" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 36" 72.6 1 Q8.9 120.0 72.6 108.9 120.0 99.3 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 24" 0„ 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 42" 64.5 9 .8 120.0 64.5 96.8 120.0 88.3 120.0 20.0 112.5 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 48" 58.6 8 .0 117.3 58.6 88.0 117.3 80.2 120.0 20.0 102.2 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 54" 54.2 81.3 108.4 54.2 81.3 108.4 74.1 111.2 20.0 94.5 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 60" 50.8 7 .2 101.7 50.8 76.2 101.7 69.5 104.3 20.0 88.6 120.0 120.0 120.0 120.0 120.0 72" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 70" 46.8 7 .2 93.6 46.8 70.2 93.6 64.0 96.0 20.0 81.6 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 120.0120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 72" 46.2 6 .3 92.4 46.2 69.3 92.4 63.2 94.8 20.0 80.5 120.0 120.0 119.5120.0 120.0 90" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 24" 108" 95.3 1 0.0 120.0 95.3 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 92" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 30" 78.7 118.0 120.0 78.7 118.0 120.0 107.6 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 96" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 36" 67.8 101.7 120.0 67.8 101.7 120.0 92.7 120.0 20.0 118.1 120.0 120.0 120.0 120.0 120.0 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 42" 60.1 9).1 120.0 60.1 90.1 120.0 82.2 120.0 20.0 104.7 120.0 120.0 120.0 120.0 120.0 120" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 48" 54.5 81.7 108.9 54.5 81.7 108.9 74.5 111.7 20.0 94.9 120.0 120.0 120.0 120.0 120.0 132" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 60" 46.9 714, 93.8 46.9 70.4 93.8 64.2 96.2 20.0 81.8 120.0 120.0 120.0 120.0 120.0 24" 2„ 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 72" 42.4 63.5 84.7 42.4 63.5 84.7 57.9 86.9 15.9 73.8 110.7 120.0 109.6 120.0 120.0 36" 112.9 120.0 120.0 112.9 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 24" 114" 89.7 1 0.0 120.0 89.7 120.0 120.0 120.0 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 95.3 120.0 120.0 95.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 30" 73.9 1 0.9 120.0 73.9 110.9 120.0 101.1 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 87.1 120.0 120.0 87.1 120.0 120.0 119.2 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 36' 63.5 95.3 120.0 63.5 95.3 120.0 86.9 120.0 20.0 110.7 120.0 120.0 120.0 120.0 120.0 72" 84.7 120.0 120.0 84.7 120.0 120.0 115.9 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 48" 50.8 73.2 101.7 50.8 76.2 101.7 69.5 104.3 20.0 88.6 120.0 120.0 120.0 120.0 120.0 84" 84.7 120.0 120.0 84.7 120.0 120.0 115.9 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 60" 43.6 6 .3 87.1 43.6 65.3 87.1 59.6 89.4 19.2 75.9 113.9 120.0 112.7 120.0 120.0 96" 84.7 120.0 120.0 84.7 120.0 120.0 115.9 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 72" 39.1 50.6 78.2 39.1 58.6 78.2 53.5 80.2 06.9 68.1 102.2 120.0 101.1 120.0 120.0 108" 84.7 120.0 120.0 84.7 120.0 120.0 115.9 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 24" 120" 84.7 1 0.0 120.0 84.7 120.0 120.0 115.9 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 24" 8" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 30" 69.7 1(4.6 120.0 69.7 104.6 120.0 95.3 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 101.7 120.0 120.0 101.7 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 36" 59.8 8).7 119.6 59.8 89.7 119.6 81.8 120.0 20.0 104.2 120.0 120.0 120.0 120.0 120.0 48" 84.7 120.0 120.0 84.7 120.0 120.0 115.9 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 46.25" 52.8 7).2 105.6 52.8 79.2 105.6 72.2 108.3 20.0 92.0 120.0 120.0 120.0 120.0 120.0 60" 76.2 114.4 120.0 76.2 114.4 120.0 104.3 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 48" 47.7 71.5 95.3 47.7 71.5 95.3 65.2 97.8 20.0 83.1 120.0 120.0 120.0 120.0 120.0 70" 72.9 109.4 120.0 72.9 109.4 120.0 99.8 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 60" 40.7 61.0 81.3 40.7 61.0 81.3 55.6 83.4 11.2 70.9 106.3 120.0 105.2 120.0 120.0 72" 72.6 108.9 120.0 72.6 108.9 120.0 99.3 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 24" 126" 80.3 140.0 120.0 80.3 120.0 120.0 109.8 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 84" 72.2 108.3 120.0 72.2 108.3 120.0 98.7 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 30" 65.9 9 .9 120.0 65.9 98.9 120.0 90.2 120.0 20.0 114.9 120.0 120.0 120.0 120.0 120.0 92" 72.2 108.3 120.0 72.2 108.3 120.0 98.7 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 36" 56.5 8 .7 112.9 56.5 84.7 112.9 77.2 115.9 20.0 98.4 120.0 120.0 120.0 120.0 120.0 96" 72.2 108.3 120.0 72.2 108.3 120.0 98.7 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 42" 49.8 7 .7 99.6 49.8 74.7 99.6 68.1 102.1 20.0 86.8 120.0 120.0 120.0 120.0 120.0 102" 72.2 108.3 120.0 72.2 108.3 120.0 98.7 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 48" 44.8 6 .3 89.7 44.8 67.3 89.7 61.3 92.0 20.0 78.2 117.2 120.0 116.0 120.0 120.0 24" 4" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 54" 41.1 61.6 82.1 41.1 61.6 82.1 56.2 84.3 12.3 71.6 107.4 120.0 106.2 120.0 120.0 36" 92.4 120.0 120.0 92.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 60" 38.1 5 .2 76.2 38.1 57.2 76.2 52.1 78.2 04.3 66.4 99.7 120.0 98.6 120.0 120.0 48" 76.2 114.4 120.0 76.2 114.4 120.0 104.3 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 24" 132" 76.2 114.4 120.0 76.2 114.4 120.0 104.3 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 71.3 107.0 120.0 71.3 107.0 120.0 97.6 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 30" 62.6 9 .8 120.0 62.6 93.8 120.0 85.6 120.0 20.0 109.0 120.0 120.0 120.0 120.0 120.0 60" 67.8 101.7 120.0 67.8 101.7 120.0 92.7 120.0 120.0 118.1 120.0 120.0 120. 120.0 120.0 36" 53.5 8 .3 107.0 53.5 80.3 107.0 73.2 109.8 20.0 93.2 120.0 120.0 120.0 120.0 120.0 70" 64.0 96.0 120.0 64.0 96.0 120.0 87.5 120.0 120.0 111.6 120.0 120.0 120. 120.0 120.0 42" 47.1 7 .6 94.2 47.1 70.6 94.2 64.4 96.6 20.0 82.1 120.0 120.0 120.0 120.0 120.0 72" 63.5 95.3 120.0 63.5 95.3 120.0 86.9 120.0 120.0 110.7 120.0 120.0 120. 120.0 120.0 48" 42.4 6 .5 84.7 42.4 63.5 84.7 57.9 86.9 15.9 73.8 110.7 120.0 109.6 120.0 120.0 84" 62.2 93.4 120.0 62.2 93.4 120.0 85.1 120.0 120.0 108.5 120.0 120.0 120. 120.0 120.0 54" 38.7 5 .1 77.5 38.7 58.1 77.5 53.0 79.4 05.9 67.5 101.2 120.0 100.2 120.0 120.0 96" 62.2 93.4 120.0 62.2 93.4 120.0 85.1 120.0 120.0 108.5 120.0 120.0 120. 120.0 120.0 60" 35.9 5 .8 71.8 35.9 53.8 71.8 49.1 73.6 8.1 62.5 93.8 120.0 92.8 120.0 120.0 24" 0" 117.3 120.0 120.0 117.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 24" 138" 72.6 1 8.9 120.0 72.6 108.9 120.0 99.3 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 84.7 120.0 120.0 84.7 120.0 120.0 115.9 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 30" 59.5 8 .3 119.0 59.5 89.3 119.0 81.4 120.0 20.0 103.7 120.0 120.0 120.0 120.0 120.0 42" 75.8 113.6 120.0 75.8 113.6 120.0 103.6 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 36" 50.8 7 .2 101.7 50.8 76.2 101.7 69.5 104.3 20.0 88.6 120.0 120.0 120.0 120.0 120.0 48" 69.3 104.0 120.0 69.3 104.0 120.0 94.8 120.0 120.0 120.0 120.0 120.0 120. 120.0 120.0 42" 44.7 6 .0 89.4 44.7 67.0 89.4 61.1 91.7 20.0 77.9 116.8 120.0 115.E 120.0 120.0 54" 64.5 96.8 120.0 64.5 96.8 120.0 88.3 120.0 120.0 112.5 120.0 120.0 120. 120.0 120.0 48" 40.1 6 .2 80.3 40.1 60.2 80.3 54.9 82.3 09.8 69.9 104.9 120.0 103.8 120.0 120.0 60" 61.0 91.5 120.0 61.0 91.5 120.0 83.4 120.0 120.0 106.3 120.0 120.0 120. 120.0 120.0 60" 33.9 5 .8 67.8 33.9 50.8 67.8 46.3 69.5 2.7 59.1 88.6 118.1 87.6 120.0 120.0 72" 56.5 84.7 112.9 56.5 84.7 112.9 77.2 115.9 120.0 98.4 120.0 120.0 120. 120.0 120.0 24' 144 69.3 1 4.0 120.0 69.3 104.0 120.0 94.8 120.0 20.0 120.0 120.0 120.0 120.0 120.0 120.0 84" 54.5 81.7 108.9 54.5 81.7 108.9 74.5 111.7 120.0 94.9 120.0 120.0 120. 120.0 120.0 30" 56.7 8 .1 113.5 56.7 85.1 113.5 77.6 116.4 20.0 98.9 120.0 120.0 120.0 120.0 120.0 92" 54.2 81.3 108.4 54.2 81.3 108.4 74.1 111.2 120.0 94.5 120.0 120.0 120. 120.0 120.0 36" 48.4 7 .6 96.8 48.4 72.6 96.8 66.2 99.3 20.0 84.4 120.0 120.0 120.0 120.0 120.0 42„ 42.5 6 .8 85.0 42.5 63.8 85.0 58.1 87.2 16.3 74.1 111.1 120.0 109.9 120.0 120.0 48" 38.1 5 .2 76.2 38.1 57.2 76.2 52.1 78.2 04.3 66.4 99.7 120.0 98.6 120.0 120.0 58.25" 32.8 4 .2 65.6 32.8 49.2 65.6 44.9 67.3 9.8 57.2 85.8 114.4 84.9 120.0 120.0 TABLE 5: m nary LO uJ J m CENTERLINE _FRAME _ 1-3/4" WIDTH 1 WIDTH W (n > FRAME WIDTH � uogduasa(7 nay 6" MAX. _ Y / U) c j N OPTIONAL Q Co72' SEE TABLE 6, HORIZONTAL C7 O THIS SHEET MULLION Q a}oQ J J FRAME / (n HEIGHT UM e a J N Q C)13 i � C) o LU cM •� Z C U TO o vI— 0 0 w W + o °N I ._ U) 0M 0 ¢ � N 6" MAX. 0-. Fro > U I � 3.: ® N M CENTERLINE Z z U- WIDTH —I o_ 2 j Q Q C 2 Cti oo z }aays C2 0 w w w a z J 7 N af 0 H � JAMB AN z w -- o � F N N O o — rn SPACING z Oj oo W � Q alpaS } _ ,� z a x d c� c� U) w � O r o o - ° L W W O� Co 0 L a. 0 0 U) o o Z o Z w w m Co w=ui V—Fa H Q i W 2 o Q (n a. c w v v O (n o a � Z a�}�l asaQ sauas ���\\\\ I I I f' \��� �6NY �YNN���'%, �'� . ' \GENSF �� No. 58705 — * * - — = 8/1 1 /21 Q STATE OF T p s%ONAL �•` `�` A. LYNN MILLER, P.E. P.E.# 58705 Jamb Anchor Spacing Shim Thickness = 1/4" Jamb Anchor Spacing Shim Thickness = 1/4" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Installed with Group "E" Anchors Nominal Dim. Installed with Group "A" Anchors Installed with Group Anchors "B" Installed with Group "C" Anchors Installed with Group "D" Anchors Installed with Group "E" Anchors Centerline Width Frame Height enterline Width Frame Height 24' 48" 18" 18" 18" 18" 18" 24" 97-3/4" 18" 18' 18" 18" 18" 36' 18" 18" 18" 18" 18" 36" 18" 18' 18" 18" 18" 48' 18" 18" 18" 18" 18" 42" 18" 18' 17-1/8" 18" 18" 60' 18" 18" 18" 18" 18" 48" 18" 18' 17-1/8" 18" 18" 72' 18" 18" 18" 18" 18" 54" 17-1/8" 18' 14-5/16" 18" 18" 84' 18" 18" 18" 18" 18" 70" 14-5/16" 18' 12-1/4" 18" 18" 96' 18" 18" 18" 18" 18" 72 14-5/16" 18' 12-1/4" 18" 18" 10 " 18" 18" 18" 18" 18" 84" 14-5/16" 18' 12-1 /4" 17-1 /8" 18" 120" 18" 18" 18" 18" 18" 24" 102" 18" 18' 18" 18" 18" 13 " 18" 18" 18" 18" 18" 30" 18" 18' 18" 18" 18" 14 " 18" 181, 18" 18" 18" 36" 18" 18' 18" 18" 18" 24' 60„ 18" 18" 18" 18" 18" 42" 18" 18' 18" 18" 18" 36' 18" 18" 18" 18" 18" 48" 18" 18' 15" 18" 18" 48' 18" 18" 18" 18" 18" 54" 18" 18' 15" 18" 18" 60' 18" 18" 18" 18" 18" 60" 15" 18' 12-7/8" 18" 18" 18" 18" 18" 18" 18" 70" 15" 18' 12-7/8" 18" 18" 84' 18" 18" 18" 18" 18" 72" 15" 18' 12-7/8" 18" 18" 90' 18" 18" 18" 18" 18" 24" 108 18" 18, 18" 18" 18" 92' 18" 18" 18" 18" 18" 3-0 18" 18' 18" 18" 18" 96' 18" 18" 18" 18" 18" 36" 18" 18' 18" 18" 18" 10811 18" 18" 18" 18" 18" 42" 18" 18' 16" 18" 18" 12 " 18" 18" 18" 18" 18" 48" 18" 18, 16" 18" 18" " 18" 18" 18" 18" 18" 60" 16" 18' 13-11/16" 18" 18" 24' 72" 18" 18" 18" 18" 18" 72" 13-11/16" 18, 12" 18" 18" 36' 18" 18" 18" 18" 18" 24" 114" 18" 18' 18" 18" 18" 48' 18" 18" 18" 181, 18" 30" 18" 18' 18" 18" 181, 60' 181.181,15 18.1181,36 18" 18, 18" 18" 18" 72' 18" 18" 15" 18" 18" 48" 17" 18' 14-9/16" 18" 18" 84' 18" 18" 15" 18" 18" 60" 14-9/16" 18' 12-3/4" 18" 18" 96' 18" 18" 15" 18" 181, 72" 14-9/16" 18' 11-5/16" 17" 18" 10 " 18" 18" 15" 18" 18" 24" 120" 18" 18' 18" 18" 18" 24' 78 18" 18" 18" 18" 18" 30" 18" 18' 18" 18" 18" 36' 18" 18" 18" 18" 18" 36" 18" 18' 18" 18" 18" 48' 18" 18" 16-1/2" 18" 18" 46.25" 18" 18' 118" 18" 181, 60' 16-1/2" 18" 16-1/2" 18" 18" 48" 18" 18' 15-7/16" 18" 18" 70' 16-1/2" 18" 13-3/16" 18" 18" 60" 15-7/16" 18, 13-1/2" 18" 18" 72' 16-1/2" 18" 13-3/16" 18" 18" 24" 126" 18" 18' 18" 18" 18" 84' 16-1/2" 18" 13-3/16" 18" 18" 30" 18" 18' 18" 18" 18" 92' 16-1/2" 18" 13-3/16" 18" 18" 36" 18" 18' 18" 18" 18" 96' 16-1/2" 18" 13-3/16" 18" 18" 42" 18" 18' 16-5/16" 18" 18" 10 16-1/2" 181, 13-3/16" 18" 18" 48" 18" 18' 14-1/4" 18" 18" 24' 84" 18" 18" 18" 18" 18" 54" 16-5/16" 18, 14-1/4" 18" 18" 36' 18" 18" 18" 18" 18" 60" 14-1/4" 18' 12-11/16" 18" 18" 48' 18" 18" 18" 18" 18" 24" 132" 18" 18' 18" 18" 18" 54' 18" 18" 14-3/8" 18" 18" 30" 18" 18' 18" 18" 18" 60' 18" 18" 14-3/8" 18" 18" 36" 18" 18' 18" 18" 18" 70' 18" 18" 14-3/8" 18" 18" 42" 18" 18' 17-1 /8" 18" 18" 72' 18" 18" 14-3/8" 18" 18" 48" 17-1/8" 18' 15" 18" 18" 84' 18" 18" 14-3/8" 18" 18" 54" 15" 18, 13-5/16" 18" 18" 96' 18" 18" 14-3/8" 18" 18" 60" 15" 18' 12" 18" 181, 24' 90" 18" 18" 18" 18" 18" 24" 138" 18" 18, 18" 18" 18" 36' 18" 18" 18" 18" 18" 30" 18" 18' 18" 18" 18" 42' 18" 18" 18" 18" 18" 36" 18" 18' 18" 18" 18" 48' 18" 18" 15-5/8" 18" 18" 42" 18" 18, 15-3/4" 18" 181, 54' 18" 18" 15-5/8" 18" 18" 48" 18" 18, 14" 18" 181, 60' 15-5/8" 18" 15-5/8" 18" 18" 60" 14" 18' 12-5/8" 18" 18" 72' 15-5/8" 18" 13" 18" 18" 24" 144" 18" 18' 18" 18" 18" 84' 15;- /8" 18" 13" 18" 18" 30" 18" 18' 18" 18" 18" 92' 15-5/8" 18" 13" 18" 18" 36" 18" 18' 18" 18" 18" 42" 18" 18' 16-1/2" 18" 18" 48 16-1/2 18 14-11/16 18"18'/// 58.25" 14-11/16" 18' 12" 1 18" 18" TABLE 6: CENTERLINE FRAME 3/4" WIDTH 1 WIDTH FRAME WIDTH 6" MAX. OPTIONAL SEE TABLE 6, HORIZONTAL THIS SHEET MULLION FRAME HEIGHT �i CgIc� U .� � z Uio ai �a W v i— °o W °W zU) 6" MAX. " U _ � U 3��C. ® O N M CENTERLINE z z L` _ a WIDTH o Q CL 0 0 U ?YU JAMB ANCHOR N vi i SPACING z 0, af N o o k C >� =usZil "r a00a O�U0O ; J } J } O J � L m0LL a°°cn < ° z w O z w w F Q H Z U L W o > U adz -�C * No. �� 48/1 11 0 . STAI ' Fc0 ss� •,// ON A. LYNN P.E./ Jamb Anchor Spacing Shim Thickness = 1/2" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Installed with Group "E" Anchors Centerline Width Frame Height 2 " 48" 18" 18" 18" 18" 18" 3131. 18" 18" 18" 18" 18" 48" 18" 18" 18" 18" 18" 6)" 18" 18" 18" 18" 18" 7?" 18" 18" 18" 18" 18" 8 „ 18" 18" 18" 18" 18" 95.1 18" 18" 18" 18" 18" 1 8" 18" 18" 18" 18" 18" 1 0" 18" 18" 18" 18" 18" 1 2" 18" 18" 18" 18" 18" 1 4" 18" 18" 18" 18" 18" 2 " 60" 18" 18" 18" 18" 18" 3 " 16" 16" 18" 18" 18" 4 16" 16" 18" 18" 18" 6 ' 16" 16" 18" 18" 18" 7 16" 16" 18" 18" 18" 8 16" 16" 18" 18" 18" 9Y. 16" 16" 18" 18" 18" 9 ' 16" 16" 18" 18" 18" 951. 16" 16" 18" 18" 18" 1 8" 16" 16" 18" 18" 18" 1 0" 16" 16" 18" 18" 18" 1 2" 16" 16" 18" 18" 18" 2 " 72„ 18" 18" 18" 18" 18" 3 ' 15" 15" 18" 18" 18" 4 ' 12" 12" 18" 18" 18" 6 ' 12" 12" 15" 18" 18" 7 ' 12" 12" 15" 18" 18" 8 12" 12" 15" 18" 18" 9 " 12" 12" 15" 18" 18" 1 8" 12" 12" 15" 18" 18" 2 „ 78„ 18" 18" 18" 18" 18" 3 " 16-1/2" 16-1/2" 18" 18" 18" 4 13-3/16" 13-3/16" 16-1/2" 18" 18" 6 " 16-1/2" 18" 18" 7 " 13-3/16" 7 " 11" 11" 13-3/16" 18" 18" 8 11" 11" 13-3/16" 18" 18" 9 " 11 " ill. 13-3/16" 18" 18" 9 ill. 13-3/16" 18" 18" 1 2" 11.1 ill. 13-3/16" 18" 18" 2 " 84" 18" 18" 18" 18" 18" 3 " 14-3/8" 14-3/8" 18" 18" 18" 4 " 12" 12" 18" 18" 18" 5 " 12" 12" 14-3/8" 18" 18" 6 " 10-5/16" 10-5/16" 14-3/8" 18" 18" 7 " 10-5/16" 10-5/16" 14-3/8" 18" 18" 7 10-5/16" 10-5/16" 14-3/8" 18" 18" 8 10-5/16" 10-5/16" 14-3/8" 18" 18" 9 " 10-5/16" 10-5/16" 14-3/8" 18" 18" 2 " 90" 18" 18" 18" 18" 18" 3 " 15-5/8" 15-5/8" 18" 18" 18" 4 " 13" 13" 18" 18" 18" 4 " 13" 13" I 15-5/8" 18" 18" 5 " 11-1 /8" 15-5/8" 18" 18" 6 " 11-1 /8" 11-1 /8" 15-5/8" 18" 18" 7 " 9-3/4" 9-3/4" 13" 18" 18" r-8 " 9-3/4" 9-3/4" 13" 18" 18" 9 " 9-3/4" 9-3/4" 13" 15-5/8" 18"Al- Jamb Anchor Spacing Shim Thickness = 1/2" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anch rs Installed with Group "C" Anchors Installed with Group "D" Anchors Installed with Group "E" Anchors Centerline Width Frame Height 24" 97 3/4 18" 18' 18" 18" 18" 36" 14-5/16" 14-5/ 6" 18" 18" 18" 42" 12-1/4" 12-1/4" 17-1/8" 18" 18" 48" 12-1/4" 12-1/4" 17-1/8" 18" 18" 54" 10-3/4" 10-3/4" 14-5/16" 18" 18" 70" 9-1/2" 9-1/ " 12-1/4" 17-1/8" 18" 72" 9-1/2" 9-1/ " 12-1/4" 17-1/8" 18" 84" 8-9/16" 8-9/ 6" 12-1/4" 17-1/8" 18" 24" 102" 18" 18 18" 18" 18" 30" 18" 18" 18" 18" 18" 36" 15" 15" 18" 18" 18" 42" 12-7/8" 12-7/8" 18" 18" 18" 48" 11-1 /4" 11-1 4" 15" 18" 18" 54" 11-1 /4" 11-1 /4" 15" 18" 18" 60 10" 10" 12-7/8" 18" 18" 70" 9" 9" 12-7/8" 18" 18" 72" 9" 9" 12-7/8" 18" 18" 24" 108" 18" 18' 18" 18" 18" 30" 16" 16' 18" 18" 18" 36" 13-11/16" 13-1116" 18" 18" 18" 42" 13-11/16" 13-11.16" 16" 18" 18" 48" 12" 12" 16" 18" 18" 60" 9-5/8" 9-5/8" 13-11/16" 18" 18" 72" 8-3/4" 8-3/4" 12" 16" 18" 24" 114" 18" 18" 18" 18" 18" 30" 17" 17" 18" 18" 18" 36" 14-9/16" 14-9/ 6" 18 18" 18" 48" 11-5/16" 11-5/ 6" 14-9/16" 18" 18" 60" 9-1/4" 9-1/ " 12-3/4" 17" 18" 72" 8-1/2" 8-1/ " 11-5/16" 14-9/16" 18" 24" 120" 18" 18' 18" 18" 18" 30" 18" 18' 18" 18" 18" 36" 13-1/2" 13-12" 18" 18" 18" 46.25" 12" 12' 18" 18" 18" 48" 10-13/16" 10-13N16" 15-7/16" 18" 18" 60" 9-13/16" 9-13/16 13-1/2" 18" 18" 24" 126" 18" 18" 18" 30" 16-5/16" 16-5/16" 18" 18" 18" 18" 36" 14-1/4" 14-1/4" 18" 18" 42" 12-11/16" 12-11/16" 16-5/16" 18" 18" 48" 11-3/8" 11-3/8" 14-1 /4" 18" 18" 54" 10-3/8" 10-3 8" 14-1/4" 18" 18" 60" 9-1/2" 9-1/2" 12-11/16" 16-5/16" 18" 24" 132" 18" 18" 18" 18" 18" 30" 17-1/8" 17-1/8" 18" 18" 18" 36" 15" 15" 18" 18" 18" 42" 12" 12" 17-1/8" 18" 18" 48" 10-15/16" 10-15/16" 15" 18" 18" 54" 10" 10" 13-5/16" 17-1/8" 18" 60" 9-1/4" 9-1/4" 12" 17-1/8" 18" 24" 138" 18" 18" 18" 18" 18" 30" 15-3/4" 15-3 4" 18" 36" 14" 14' 18" 18" 18" 42" 12-5/8" 15-3/4" 18" 18" 48" 11-7/16" 11-7/16" 14" 18" 18" 60" 9" 9" 12-5/8" 15-3/4" 18" 24" 144" 18" 18" 30" 16-1/2" 16-1/2" 18" 18" 18" 36" 14-11/16" 14-1116" 18" 18" 18" 42" 12" 1�6- 16-1/2" 18" 18" 48" 11" 1 14-11/16" 18" 18" 58.25" 9-7/16" 9-7/ 12" 16-1/2" 18" III/// YNN� �''% i :NSF i8705 k = "E OF •' �(/ RIDP. •����� 91LLER, P.E. 58705 TABLE 7 Mid -Panel Anchor Quantity Shim Thickness = 1/4" Nominal Dim. Installed with Group "A" Anchors Installed with Group " Anchors " Installed with Group "C" Anchors Installed with Group "D" Anchors Installed with Group "E" Anchors Centerline Width Frame Height 24" 48" 1 1 1 1 1 36" 1 1 1 1 1 48" 2 2 2 2 1 60" 3 2 2 2 2 72" 4 3 3 3 3 84" 5 4 4 4 4 96" 5 5 5 5 5 108" 6 6 6 6 6 120" 7 6 6 6 6 132" 8 7 7 7 7 144" 9 8 8 8 8 24" 60„ 1 1 1 1 1 36" 1 1 1 1 1 48" 2 2 2 2 1 60" 3 2 2 2 2 72" 4 3 3 3 3 84" 5 4 4 4 4 90" 6 4 4 4 4 92" 6 5 5 5 5 96" 6 5 5 5 5 108" 7 6 6 6 6 120" 8 6 6 6 6 132" 9 7 7 7 7 24" 72„ 1 1 1 1 1 36" 1 1 1 1 1 48" 2 2 2 2 1 60" 3 2 2 2 2 72" 4 3 3 3 3 84" 5 4 4 4 4 96" 7 5 5 5 5 1081, 1 8 6 6 6 6 24" 78„ 1 1 1 1 1 36" 1 1 1 1 1 48" 2 2 2 2 1 60" 3 2 2 2 2 70" 4 3 3 3 3 72" 4 3 3 3 3 84" 5 4 4 4 4 92" 6 5 5 5 5 96" 7 5 5 5 5 102" 7 6 6 5 5 24" 84" 1 1 1 1 1 36" 1 1 1 1 1 48" 2 2 1 2 2 1 54" 3 2 2 2 2 60" 3 2 2 2 2 70" 4 3 3 3 3 72' 4 3 3 3 3 84" 5 4 4 4 4 96" 7 5 5 5 5 24" 90" 1 1 1 1 1 36" 1 1 1 1 1 42" 2 1 1 1 1 48" 2 2 2 2 1 54" 3 2 2 2 2 60" 3 2 2 2 2 72" 4 3 3 3 3 84" 5 4 4 4 1 4 92" 6 5 5 5 5 Mid -Panel Anchor Quanti y Shim Thickness = 1/4" Nominal Dim. Installed with Group "A" Anchors I nste wil Group Anchors Iled h "B" Installed with Group "C" Anchors Installed with Group "D" Anchors Installed with Group "E" Anchors Centerline Width Frame Height 24" 1 97-3/4" 1 1 1 1 1 36" 1 1 1 1 1 42" 2 1 1 1 1 48" 2 2 2 2 1 54" 3 2 2 2 2 70" 4 3 3 3 3 72" 4 3 3 3 3 84" 5 4 4 4 4 24" 102" 1 1 1 1 1 30" 1 1 1 1 1 36" 1 1 1 1 1 42" 2 1 1 1 1 48" 2 2 2 2 1 54" 3 2 2 2 2 60" 3 2 2 2 2 70" 4 3 3 3 3 72" 4 3 3 3 3 24" 108" 1 1 1 1 1 30" 1 1 1 1 1 36" 1 1 1 1 1 42" 2 1 1 1 1 48" 2 2 2 2 1 60" 3 2 2 2 2 72" 4 3 3 3 3 24" 114" 1 1 1 1 1 30" 1 1 1 1 1 36" 1 1 1 1 1 48" 2 2 2 2 1 60" 3 2 2 2 2 72" 4 3 1 3 3 3 24" 120" 1 1 1 1 1 30" 1 1 1 1 1 36" 1 1 1 1 1 46.25" 2 1 1 1 1 48' 2 2 2 2 1 60" 3 2 2 2 2 24" 126" 1 1 1 1 1 30" 1 1 1 1 1 36" 1 1 1 1 1 42" 2 1 1 1 1 48" 2 21 2 2 1 54" 3 2 2 2 2 60" 3 2 2 2 2 24" 132" 1 1 1 1 1 30" 1 1 1 1 1 36" 1 1 1 1 1 4_2 2 1 1 1 1 48" 2 2 2 2 1 54" 3 2 2 2 2 60" 3 2 2 2 2 24" 138" 1 1 1 1 1 30" 1 1 1 1 1 36" 1 1 1 1 1 42° 2 1 1 1 1 48" 2 2 2 2 1 60" 3 2 2 2 2 24" 144" 1 1 1 1 1 30" 1 1 1 1 1 36" 1 1 1 1 1 42" 2 11 1 1 1 48" 2 2 2 2 1 58.25" 3 2 2 2 2 FRAME HEIGHT SILL ANCHORAGE SHOWN, HEAD SIMILAR, QUANTITY MAY VARY MID -PANEL ANCHOR PATTERN NOTES: 1. MID -PANEL ANCHORS TO BE EQUALLY SPACED, +/- 1/2". Im CENTERLINE CENTERLINE CENTERLINE (i nab WIDTH �f WIDTH �f WIDTH I� J Q F- 0 CA W uoi}duosa(j nab{ Y � U>) M N O Cy') U) C:) u R O C a}oQ S, SEE J 2&3 i J �e J N uMaaQ 0 a o H Z Q M vl— o oW W U Q W oN z � 0 DMO IS N U 3: 'M ci ® C•NM� ZZW� LL 0 0 �oQ� O O o Q o Z }aa4S ?YU L J_ N r � r �"t N O N Z Z�� opW= * O a,00s W = ¢�v (906 U)W0� I` C) } O J O J LL LL W W L) mCD OW appcn O w=W ozFa m M W o > F- U) Cn a Z a!}!1 osa0 sauas LYNN * : No. 58705 Q ' STATE OF . F4 OR0% !0NAI � 0`'�`���� A. LYNN MILLER, P.E. P.E.# 58705 EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. U CORNER SEE TABLE 3 OR SEE TABLE 3 OR CORN ANCHORS, EE 4, SHEETS 5 OR 6 4, SHEETS 5 OR 6 ANCHOR SHEETS 2 & 3 SHEETS MID -PANEL MID -PANEL MID -PANEL ANCHORS, SEE ANCHORS, SEE ANCHORS, SEE TABLE 7, THIS TABLE 7, THIS TABLE 7, THIS SHEET SHEET SHEET TABLE 8: Mid -Panel Anchor Quantity Shim Thickness = 1/2" Nominal Dim. Installed with Group "A" Anchors InstalledInstalled with Group " Anchor " with Group "C" Anchors Installed with Group "D" Anchors Installed with Group "E" Anchors Centerline Width Frame Height 24" 48'' 1 1 1 1 1 36" 2 2 2 1 1 48" 3 3 2 2 1 60" 4 4 3 3 2 72" 6 6 4 3 3 84" 7 7 5 4 4 96" 8 8 6 5 5 108" 9 9 7 6 6 120" 11 11 8 6 6 132" 12 12 9 7 7 144" 13 13 10 8 8 24" 60„ 1 1 1 1 1 36" 2 2 2 1 1 48" 3 3 2 2 1 60" 4 6 4 3 3 2 72" 6 5 4 3 84" 8 8 6 5 4 90" 8 8 6 5 4 92" 9 9 6 5 5 96" 9 11 9 7 5 5 108" 11 8 6 6 120" 12 12 9 7 6 132" 14 14 10 8 7 24" 72„ 1 1 1 1 1 36" 2 2 2 1 1 48" 3 3 2 2 1 60" 4 4 3 3 2 72" 6 6 5 4 3 84" 8 8 6 5 4 96" 10 10 7 6 5 108" 12 12 9 7 6 24" 78„ 1 1 1 1 1 36" 2 2 2 1 1 48" 3 3 2 2 1 60" 4 4 3 3 2 70" 6 6 4 4 3 72" 6 6 5 4 3 84" 8 8 6 5 4 92" 10 10 7 6 5 96" 10 10 8 6 5 102" 11 11 8 7 5 24" 84'' 1 1 1 1 1 36" 2 2 2 1 1 48" 3 3 1 2 2 1 54" 4 4 3 2 2 60" 4 4 3 3 2 70" 6 6 4 4 3 72" 6 6 5 4 3 84" 8 10 8 6 5 4 96" 10 8 6 5 24" 90" 1 1 1 1 1 36" 2 2 2 1 1 42" 2 2 2 2 1 48" 3 4 4 3 2 2 1 54" 4 3 2 2 60" 4 3 3 2 72" 6 6 1 5 4 3 84" 8 8 1 6 5 4 92" 10 10 1 7 6 5 Mid -Panel Anchor Quantity Shim Thickness = 112" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Installed with Group "E" Anchors Centerline Width Frame Height 24" 97-3/4" 1 1 1 1 1 36" 2 2 2 1 1 42" 2 2 2 2 1 48" 3 3 2 2 1 54" 4 4 3 2 2 70" 6 6 4 4 3 72" 6 6 5 4 3 84" 8 A 6 5 4 24" 102" 1 11 1 1 1 30" 1 1 1 1 1 36" 2 2 1 1 42" 2 2 2 1 48" 3 2 2 1 54" 4 3 2 2 60" 4 3 3 2 70" 6 4 4 3 72" 6 5 4 3 24" 1 108" 1 1 1 1 1 30" 1 1 1 1 1 36" 2 2 1 1 CT 2 2 2 2 1 48" 3 3 2 2 1 60" 4 4 3 3 2 72" 6 6 5 4 3 24" 114" 1 1 1 1 1 30" 1 1 1 1 1 36" 2 2 2 1 1 4_8 3 3 2 2 1 60" 4 4 3 3 2 72" 6 6 5 4 3 24" 120" 1 1 1 1 1 30" 1 1 1 1 1 36" 2 2 1 1 46.25" 2 2' 2 2 1 48" 3 2 2 1 60" 4 4 3 3 1 2 24" 126" 1 1 1 1 1 30" 1 1 1 1 1 36" 2 2 1 1 42" 2 2 2 2 1 4- 3 a 2 2 1 54" 4 4 3 2 2 60" 4 4 3 3 2 24" 132" 1 1 1 1 1 30" 1 1 1 1 1 36" 2 2 1 1 42" 2 2 2 1 48" 3 3 2 2 1 54" 4 4 3 2 2 60" 4 4 3 3 2 24" 138" 1 1 1 1 1 30" 1 1 1 1 1 36" 2 2, 2 1 1 42" 2 2' 2 2 1 48" 3 3 2 2 1 60" 4 4 3 3 2 24" 144" 1 1 1 1 1 1 30" 1 1 1 1 1 36" 2 2 2 1 1 42" 2 2 2 2 1 48" 3 3 2 2 1 58.25" 4 4 3 3 2 FRAME HEIGHT SILL ANCHORAGE SHOWN, HEAD SIMILAR, QUANTITY MAY VARY MID -PANEL ANCHOR PATTERN NOTES: 1. MID -PANEL ANCHORS TO BE EQUALLY SPACED, +/- 1/2". m CENTERLINE q CENTERLINE (E CENTERLINE q nab WIDTH WIDTH �f WIDTH 00 W J Q W UJI uoi}duosa(j 'nay C>/) M N O Cy') U) O u R O C a}oQ S, SEE J S2&3 i J i �e j CV uMOJQ O Q O c3lZ b W M ,41v' z i C� c C/i vl— O E5 ow W w .(IN I L z¢ � HMO ® O N M L L zZLL CY)� > O O �o—o O 60 2 o Z }aa4S () W L J_ N af af ��" NO�i N Z Z w p W= * O a/pos o w = ¢�v �U)W06 0� � 00 Of O }OJ �o Jo LL W W Ltd CO O w a 0 0 U) O o=w Ozww m M wUU U��a O Ch a�Z (_9 Q WoW � 07 a Z a } l osaQ sa!Jas ♦♦♦ ONY LYNN 4 �,• ��'��•'' \,\GENSF • ���� * / No. 58705 /21 Q ' STATE OF ��sS.F[ORIDP`. YONAL /01111110 A. LYNN MILLER, P.E. P.E.# 58705 EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. U ANCHORS, EE CORNER SEE TABLE 3 OR SEE TABLE 3 OR CORN ANCHOR SHEETS 2 & 3 4, SHEETS 5 OR 6 4, SHEETS 5 OR 6 SHEET MID -PANEL MID -PANEL MID -PANEL ANCHORS, SEE ANCHORS, SEE ANCHORS, SEE TABLE 8, THIS TABLE 8, THIS TABLE 8, THIS SHEET SHEET SHEET TABLE 9: w m AVERAGE CENTERLINE CENTERLINE o + _ CENTERLINE = WIDTH 1 WIDTH 2 WIDTH 2 Q Maximum Vertical Mullion Design Pressure, (psf) Anchorless Jamb Pressure, Design (psf) Maximum Vertical Mullion Design Press re, (psf) Anchorless Jamb Pressure, Design (psf) o 0 0 CENTERLINE CENTERLINE Q WIDTH 1 WIDTH 2 o6 Average Centerline Width Frame Height No Reinforcement Alum. Reinforcement (part #4) Rein (p teel orcement rt #10) No Reinforcement Steel Reinforcement (part #10) Average Ce terline idth Frame Height No Reinforcement Alum. Reinforcement (part #4) Steel Reinforcement (part #10) No Reinforcement Steel Reinforcement (part #10) M w m F / o W co 24" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 4" 97-3/4" +90/-90 +90/-100 +90/-120 +60/-75 +90/-100 36" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 6" +90/-90 +90/-100 +90/-120 +60/-75 +90/-100 48" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 2" +87.9/-87.9 +90/-100 +90/-120 +60/-75 +90/-100 60" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 8" +80/-80 +90/-100 +90/-120 +60/-75 +90/-100 72" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 4" +90/-100 +90/-120 +60/-75 +90/-100 84" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 14" 0" +90/-100 +60/-65 48" w 2 0_ OPTIONAL HORIZONTAL uoi}duosaQ Aay 96" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 2" +90/-100 +60/-65 108" +90/-100 + 0/-120 +60/-75 +90/-100 +60/-65 +60/-65 120" +90/-100 + 0/-120 +90/-100 4" +90/-90 +90/-100 +90/-120 +60/-75 +90/-100 MULLION 132" + 0/-100 +60/-65 0" +90/-90 +90/-100 +90/-120 +60/-75 +90/-100 144" + 0/-100 +60/-65 6" +88.3/-88.3 +90/-100 +90/-120 +60/-75 +90/-100 Y r FRAME Cn CY) 24" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 2" +77.1/-77.1 +90/-100 +90/-120 +60/-75 +90/-100 102" HEIGHT ANCHORLESS CV 36" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 8" +90/-100 +90/-120 +60/-75 +90/-100 JAMB O CD O 48" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 4" +90/-100 +90/-120 +60/-75 +90/-100 60" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 0" +90/-100 +60/-65 72" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 0" +90/-100 +60/-65 60„ a}oQ O J U) J X2 J N uMOJQ Q O O 14 W L0 " o f) •� = z Q U 00 C/i Q 1 a o' 1 - o 2 E5 o w LLl 0 °N MO L — >- Q0 O_ Cr"-1 � E � = o C9 ® o N M 1.521" 1.125" Z Z LL M O Lo oo g O LO U g o Q U o V C, >z_ }aays w 6 z Y Q > U) N vi j N 0 o - rn Z Z 4.752" 4.751" z °' O p w = � 0 7077 } p = oa z a = — 187" d 0 v CD U) w � � O L O } >- o -j oLL LL W LLl O� .188" MOLL aoocn o o Z o Z w w J M Q w 0 0 LLO w m O a w c7 v Q o U ~ U a z a } l ssaQ sauas O ALUMINUM 10 STEEL REINFORCEMENT REINFORCEMENT `����IIII�►///�7� ��� r1Y LYNN �� ��• 'Y/�� ��� \ �'� , �,\GENSF '• �� 84" +90/-100 + 0/-120 +60/-75 +90/-100 2" +60/-65 +60/-65 90" +90/-100 + 0/-120 +60/-75 +90/-100 4" 108" +90/-90 +90/-100 +90/-120 +60/-75 +90/-100 92" +90/-100 + 0/-120 +60/-75 +90/-100 0" +87.5/-87.5 +90/-100 +90/-120 +60/-75 +90/-100 96" +90/-100 + 0/-120 +90/-100 6" +74/-74 +90/-100 +90/-120 +60/-75 +90/-100 108" + 0/-100 +60/-65 2" +64.5/-64.5 +90/-100 +90/-120 +60/-75 +90/-100 120" + 0/-100 +60/-65 8" +90/-100 +90/-120 +60/-75 +90/-100 132" + 0/-65 +60/-65 0" +90/-100 +60/-65 24" 72 +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 2" +60/-65 +60/-65 36" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 4" 114" +90/-90 +90/-100 +90/-120 +60/-75 +90/-100 48" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 0" +74.2/-74.2 +90/-100 +90/-120 +60/-75 +90/-100 60" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 6" +62.6/-62.6 +90/-100 +90/-120 +60/-75 +90/-100 72" +90/-100 + 0/-120 +60/-75 +90/-100 81, +90/-100 +90/-120 +60/-75 +90/-100 84" + 0/-100 +60/-65 0" +90/-100 +60/-65 96" + 0/-100 +60/-65 2" +60/-65 +60/-65 108" + 0/-65 +60/-65 4" 120" +78.5/-78.5 +90/-100 +90/-120 +60/-75 +90/-100 24" 78 +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 0" +63.4/-63.4 +90/-100 +90/-120 +60/-75 +90/-100 36" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 6" +53.5/-53.5 +90/-100 +90/-120 +60/-75 +90/-100 48" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 4 .25" +90/-100 +90/-120 +60/-75 +90/-100 60" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 8" +90/-100 +90/-120 +90/-100 70" +90/-100 + 0/-120 +60/-75 +90/-100 0" +90/-100 +60/-65 72" +90/-100 + 0/-120 +90/-100 4" 126" +67.7/-67.7 +90/-100 +90/-120 +60/-65 84" + 0/-100 +60/-65 0" +54.6/-54.6 +90/-100 +90/-120 +60/-65 92" + 0/-100 +60/-65 6" +46/-46 +90/-100 +90/-120 +60/-65 96" + 0/-65 +60/-65 2" +87.1/-96.8 +90/-116.5 +60/-65 102" + 0/-65 +60/-65 8" +90/-100 +60/-65 24" 84" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 4" +84/-93.4 +60/ 65 36" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 0" +60/-65 +60/-65 48" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 4" 132" +58.8/-58.8 +90/-100 +90/-120 +60/-65 54" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 0" +47.4/-47.4 +90/-100 +90/-120 +60/-65 60" +90/-100 + 0/-120 +60/-75 +90/-100 6" +87.1/-96.7 +90/-116.4 +60/-65 70" + 0/-100 +60/-65 2" +75.4/-83.8 +90/-100.9 +60/-65 72" + 0/-100 +60/-65 8" +80.5/-89.4 +60/-65 84" + 0/-100 +60/-65 4" +72.6/-80.6 +60/-65 96" + 0/-65 +60/-65 0" +60/-65 +60/-65 24" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 4" 138" +51.4/-51.4 +90/-100 +90/-120 +60/-65 36" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 0" +41.4/-41.4 +90/-100 +90/-120 +60/-65 42" +90/-90 +90/-100 + 0/-120 +60/-75 +90/-100 6" +76/-84.4 +90/-101.6 +60/-65 48" +89.4/-89.4 +90/-100 + 0/-120 +60/-75 +90/-100 2" +79.2/-88 +60/-65 90" NOTES: _ * ; No. 58705 — 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE _ -� o c�X — APPROVAL, (STOREFRONT ENTRANCE DOOR, PTAC LOUVER 8/1 1 /21 54" +90/-100 +i 0/-120 +60/-75 +90/-100 8" +70.1/-77.9 +60/-65 60" +90/-100 + 0/-120 +60/-75 +90/-100 0" +60/-65 +60/-65 72" + 0/-100 +60/-65 4" +45.2/-45.2 +90/-100 +90/-120 +60/-65 84" + 0/-65 +60/-65 0" +36.4/-36.4 +79.5/-88.3 +90/-106.3 +60/-65 92" + 0/-65 +60/-65 6" +66.7/-74.1 +80.3/-89.3 +60/-65 144" OR WINDOW INSERT) THE LESSER DESIGN PRESSURE O STATE OF VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2" +69.5/-77.2 +60/-65 8" +61.5/-68.3 +60/-65 5 .25" +60/-65 +60/-65 A. LYNN MILLER, P.E. P.E.# 58705 APPROVED MULLION, DETAIL D DETAIL Al DETAIL B DETAIL C ALUMINUM, STEEL FRAMING STOREFRONT OR STEEL STUD. SEE TABLE WINDOW TO DOOR INTO MASONRY MULLION 1/4" NUT & BOLT, 24" MAX. INTO METAL 1, SHEET 1. EMBEDMENT REINFORCEMENT #4 OR #10 FROM EACH END AND 24" MAX 1-3/4" ° 3 REQUIRED, SEE TABLE 9 10 O.C. TYP. ANCHOR TYPE, _ _ _ _ _ 1/4" NUT & BOLT, 24" a 6 OPTIONAL EMBEDMENT BEAD AND r MAX. FROM EACH ° a — ----� I EDGE DIST. a — — EDGE DISTANCE PER EDGE DIST. END AND 24" MAX O.C. SUBSTRATE, SEE = 1 3/8 c — �' TABLE 1, SHEET 1. i �1 TYP. ANCHOR TYPE, ° 40 OPTIONAL �11 LAMI IG GLASS EMBEDMENT AND A= ATTACHED EDGE DISTANCE PER ° 1 1 STOREFRONT SUBSTRATE, SEE DOOR, a L1 TABLE 1, SHEET 1. e ---------- SEE SEPARATE APPROVALFOR CONCRETE/CMU a °d. /SPECIFICATIONS PER ANCHOR REQUIREMENT DAYLIGHT OPENING WIDTH 42 EXTERIOR 41 EXTERIOR EXTERIOR m `'a 1 2 L ------------� 15 FRAME WIDTH 1/2" MAX. SHIM i- 1/2" MAX. SHIM — — — — — — — EMBEDMENT a. EDGE DIST. TYP. ANCHOR a TYPE, a ° EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. ° CONCRETE/CMU PER ANCHOR—' REQUIREMEN 1/2" MAX. GAP DETAIL A4 ANCHORLESS JAMB REINFORCED TO 2X WOOD 2X WOOD BUCK_I OR FRAMING O 1X WOOD BUCKSTRIP, SEE NOTE 2, THIS SHEET 1/2" MAX. I� SHIM EMBEDMENT DETAIL A2 t THRU 1X WOOD EDGE DIST. INTO MASONRY i TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. 2X WOOD BUCK EXTERIOR OR FRAMING 1/4" NUT & BOLT, 6" MAX. FROM EACH END AND 24" MAX O.C. REQUIRED BACKBEDDING 20" OUT FROM FRAME CORNERS U l 100% EXTENSION JOINT MOVEMENT CAPABLE SEALANT (BY OTHERS) REQUIRED AT JAMBS. SEALANT MUST BE COMPATIBLE WITH ALLADJACENT MATERIALS. DETAIL A3 INTO 2X WOOD O 1/4" NUT & BOLT, 24" MAX. FROM TOP OF FRAME, REQUIRED FOR TRANSOM HEIGHTS OVER 22-1/4" (SEE SEPARATE APPROVAL) EXTERIOR 1/2" MAX. SHIM 1/2" MAX. GAP DETAIL A5 ANCHORLESS JAMB NON -REINFORCED TO MASONRY CONCRETE/CMU PER ANCHOR °a �a REQUIREMENT a° ,aa EXTERIOR IIIII///// Comm . Q`, ® Architectural Products * : No. 58705 * _ CGI WINDOWS AND DOORS, INC. 10100 NW 25TH STREET MIAMI, FL 33172; (305) 593-6590 Y PREPARED BY: A. LYNN MILLER 1070 TECHNOLOGY DRIVE 8/ 1 1 /21 (v i O STATE OF N. VENICE, FL 34275; (941) 480-1600 COPYRIGHT© 2020 S v�� 10 SNAL �\ `� CGIWIWINDOWS& DOORS, LIMITED O MAKE A. LYNN MILLER, P.E. COPIES FOR PERMITTING. CERT. OF AUTH. #29296 P.E.# 58705 DETAIL E STOREFRONT WINDOW TO TRANSOM INSTALLATION NOTES: I ATTACHED �II STOREFRONT DOOR TRANSOM, I SEE SEPARATE I APPROVAL FOR 11 SPECIFICATIONS 2' I 11 II II illl I II IL�T-- II USE ONLY SUBSTRATE APPROPRIATE ANCHORS, FOLLOW EMBEDMENT, EDGE DISTANCE AND SUBSTRATE REQUIREMENTS PER TABLE 1, SHEET 1. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. ALL ANCHOR HEAD TYPES ARE ALLOWED. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL. UNIT MAY BE INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1 X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. MAXIMUM SHIM THICKNESS TO BE AS REQUIRED BY TABLES 3-8, SHEETS 5-10. Revised By: Dote: Revision: HC 08/10/21 ADDED DETAIL A4 & A5, GLASS STOP GASKET CHANGE Revised By: Dote: Revision: Description: Drown By: HORIZONTAL X—SECTION J ROSOWSKI I itic: Date: STOREFRONT WINDOW SYSTEM DETAILS — LMI 03/23/16 Series/Model: Scaie: Sheet: Drawing No. Rev: SS-3500 NTS 12 OF 16 MD-3500-2—LM B DETAIL F1 THRU 1X WOOD CONCRETE/CMU PER INTO MASONRY ANCHOR REQUIREMENT 1X WOOD BUCKSTRIP, SEE _ EDGE NOTE 2, THIS SHEET. DISTANCE m v w B FRAME HEIGHT 1/2" MAX. EXTERIOR a T DAYLIGHT OPENING HEIGHT EXTERIOR a 41 31 2X WOOD BUCKSTRIP OR FRAMING, SEE ANCHOR NOTE 3, SHEET 1 EMBEDMENT F_7�� L 1/2" MAX.vTr _ 7 TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. OPTIONAL 6 BEAD 1 60" MAX. HORIZ. MULLION LENGTH DETAIL G HORIZ. MULLION OPTIONAL LAMI IG GLASS TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE,SEE TABLE 1, SHEET 1. (3) REQUIRED AT EACH ANCHOR LOCATION 1/2" MAX. SHIM ° o EMBEDMENT o ° p° o ° ° CONCRETE/CMU PER ° ° EDGE ANCHOR REQUIREMENT DIST. DETAIL H INTO MASONRY DETAIL F2 INTO WOOD DETAIL F3 INTO MASONRY CONCRETE/CMU _ EDGE _ PER ANCHOR DISTANCE EDGE REQUIREMENT DISTANCE vP ° v no EMBEDMENT EMBEDMENT o ° p v v 1/2" 1/2" � a MAX. MAX. TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. L 1/2" j MAX. 9 a EXTERIOR a EDGE DISTANCE EMBEDMENT a TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1. SHEET 1. DETAIL F4 INTO METAL APPROVED MULLION, FBC COMPLIANT ALUMINUM/STEEL FRAMING OR STEEL STUD. MAY BE VERTICAL OR HORIZONTAL. SEE SUBSTRATE PROPERTIES, TABLE 1, SHEET 1 EDGE \ a DISTANCE EMBEDMENT TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. INSTALLATION NOTES: EXTERIOR TYP. ANCHOR TYPE, 1. USE ONLY SUBSTRATE APPROPRIATE a EMBEDMENT AND ANCHORS, FOLLOW EMBEDMENT, EDGE EDGE DISTANCE DISTANCE AND SUBSTRATE 41 PER SUBSTRATE, REQUIREMENTS PER TABLE 1, SHEET 1. SEE TABLE 1, ANY INSTALLATION OPTION SHOWN 31 SHEET 1. MAY BE USED ON ANY SIDE OF THE \ WINDOW. ALL ANCHOR HEAD TYPES ARE ALLOWED. 2. 4" LENGTH ANCHOR $ CHANNEL AT INSTALLATION ANCHORS. SEE SHEET 1 FOR REQUIRED LOCATIONS ALSO SEE FIGURE 1 BELOW. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL. UNIT MAY BE INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE #6 X 1-5/8" BUGLE -HEAD 51 SMS, 2-1/2" FROM EACH STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY END & 13-1/2" MAX. O.C. OF THE ENGINEER OR ARCHITECT OF DETAIL I RECORD. MAXIMUM SHIM THICKNESS TO BE AS REQUIRED BY TABLES 3-8, CURVED HEADER SHEETS 5-10. FIGURE 1: REMOVE s LTIVN ; `��`?`• ��cENsF • <<�,%, Commercial ..........................................................._ ......... Q`. P ® Architectural Products * : No. 58705 * _ CGI WINDOWS AND DOORS, INC. 5 *9�Q/� 10100 NW 25TH STREET MIAMI, FL 33172; (305) 593-6590 ai ` ` PREPARED BY: A. LYNN MILLER • 8/ 1 1 /21 (v O� STATE OF \ 1070 TECHNOLOGY N. V NICE, FLL 342 5D1E 9 480-1600 IF OD FIED AS //S�ONAt. `�\\\ CGI WINDOWS I SUSED HOWN ABOVE. LIMITED O MAKE A. LYNN MILLER, P.E. COPIES FOR PERMITTING. CERT. OF AUTH. #29296 P.E.# 58705 Revised By: Datc: HC 08/10/21 Revised By: Date: 1/2" MAX. SHIM EMBEDMENT 0 DETAIL H _ EDGE INTO MASONRY DIST. NOTE: REVERSED -GLAZING EXAMPLE ABOVE IS APPLICABLE FOR ALL SIDES AND SUBSTRATES SHOWN ON APPROVAL. Revision: GLASS STOP GASKET CHANGE Revision: Description: Drawn By: VERTICAL X-SECTION J ROSOWSKI Title: Date: STOREFRONT WINDOW SYSTEM DETAILS - LM 03/23/16 SerieslModel: Scale: Sheet: Drawing No. Rev: SS-3500 NTS 13 OF 16 MD-3500-2-LM B 40 1/4" NUT & BOLT, 24" MAX. FROM EACH END AND 24" MAX O.C. 2 DETAIL J PTAC LOUVER & WINDOW INSERT NOTES: PTAC INSERT 1. REFER TO SEPARATE WINDOW APPROVAL FOR ALL WINDOW INSERT REQUIREMENTS AND I, INSTALLATION. - ' 2. AWNING WINDOW INSERT SHOWN BUT MAY BE ANY REFER TO PTAC LOUVER APPROVED PGT WINDOW WITH A FLANGED FRAME. %, APPROVAL FOR LOUVER L INSTALLATION REQUIREMENTS 3. REFER TO PTAC LOUVER APPROVAL FOR ALL PTAC y II LOUVER REQUIREMENTS AND INSTALLATION. 4. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW II SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE PTAC LOUVER, REFER TO yt " L JL SYSTEM. SEPARATE APPROVAL FOR INSTALLATION REQUIREMENTS INSTALLATION NOTES: L L 1. USE ONLY SUBSTRATE APPROPRIATE ANCHORS, FOLLOW EMBEDMENT, EDGE DISTANCE AND ,� REMOVE GLAZING LEG AS SUBSTRATE REQUIREMENTS PER TABLE 1, SHEET EXTERIOR ;{' ;; REQUIRED FOR PTAC 1. ANY INSTALLATION OPTION SHOWN MAY BE LOUVER INSTALLATION USED ON ANY SIDE OF THE WINDOW. ALL ANCHOR HEAD TYPES ARE ALLOWED. 1.750" 1 /2" MAX. SHIM o n�� DETAIL K ° p � EMBEDMENT PTAC INSERT p o CONCRETE/CMU PER, EDGE ANCHOR REQUIREMENT DIST. DETAIL L PTACINSERT 1.750" JT & BOLT, 24" :ROM EACH END 4" MAX O.C. MOVE GLAZING LEG AS REQUIRED FOR PTAC LOUVER INSTALLATION 2. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL. UNIT MAY BE INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. MAXIMUM SHIM THICKNESS TO BE AS REQUIRED BY TABLES 3-8, SHEETS 5-10. PTAC LOUVER, REFER TO— EXTERIOR DETAIL M SEPARATE APPROVAL FOR INSTALLATION REQUIREMENTS � PTAC INSERT 2X WOOD BUCKSTRIP OR FRAMING, SEE ANCHOR NOTE 3, SHEET 1 L 1/2" MAX. L_ CVTCO I'I LN EDGE _ DISTANCE EMBEDMENT 1.750" DETAIL N WINDOW INSERT CGI, PGT OR WINDOOR FLANGED WINDOW (AWNING SHOWN), REFER TO SEPARATE APPROVAL FOR INSTALLATION REQUIREMENTS I n ' I I ' I I ii I CGI, PGT OR WINDOOR it 1.750" f FLANGED WINDOW NUT & BOLT, 24" (AWNING SHOWN), REFER FROM EACH END TO SEPARATE APPROVAL AND 24" MAX O.C. FOR INSTALLATION REQUIREMENTS 40-- -i--- T.- -- — lrl 5FFIA T , ' LL— DETAIL P REMOVE GLAZING LEG WINDOW INSERT @ WINDOW INSERT VUT & BOLT, 24" FROM EACH AND 24" MAX O.C. DETAIL O WINDOW INSERT EXTERIOR DETAIL Q WINDOW INSERT = * No. Q� STA' FC C A. LYNN P P.EJ iIII /// :NSF i8705 k = i2��r; 'E OF Al— `\\�\ 1ILLER, P.E. 58705 _ 9/16" LAMINATED 1/4" ANNEALED GLASS STACK GLASS EXTERIOR 090" SGP- 42 3/4" GLASS 41 BITE 1/4" ANNEALED GLASS 40 GLASS TYPE A 1/4" HEAT - STRENGTHENED GLASS EXTERIOR .090" SGP a t4l� 3/4" GLASS BITE 1/4" HEAT - STRENGTHENED EXTERIOR GLASS a 1 090" PVB 1 tl� 3/4" GLASS BITE 9/16" LAMINATED GLASS STACK 1/4" H EAT- STRENGTI GLASS 40 GLASS TYPE B 9/16" LAMINATED _ 1-3/16" I.G. GLASS STACK �� i _ 9/16" LAMINATED GLASS STACK GLASS STACK 1/4" ANNEALED GLASS EXTERIOR 7/16" AIRSPACE 1/4" HEAT- STRENGTHENED a 090" SGP TEMPERED GLASS GLASS GLASS 42 3/4" GLASS ��4�O BITE 41 40 3� u� GLASS TYPE C 1-3/16" I.G. 9/16" LAMINATED _ _ _ GLASS STACK GLASS STACK 1/4" HEAT - STRENGTHENED GLASS 7/16" AIRSPACE EXTERIOR PVB 1/4" TEMPERED .090" aGLASS 42 3/4" GLASS BITE 41 40 3� 47 GLASS TYPE E 31 "` GLASS TYPE D 1-3/16" I.G. 9/16" LAMINATED GLASS STACK GLASS STACK 1/4" HEAT - STRENGTHENED GLASS 7/16" AIRSPACE EXTERIOR 090" SGP 1/4" TEMPERED a GLASS 42 3/4" GLASS BITE 41 aO�7n4O NOTES: 1. GLAZING FOR ALL GLASS TYPES MEETS ASTM E1300 FOR ALL APPROVED SIZES. "PVB" = .090" TROSIFOL® PVB INTERLAYER BY KURARAY AMERICA, INC. "SG" = .090" SENTRYGLAS® INTERLAYER BY KURARAY AMERICA, INC. GLASS TYPE F STRUCTURAL POLYISOBUTYLENE WITH DESICCANT INT. GLASS SILICONE 1/4" NOM. EXT. GLASS 36 KODISPACE® 4SG TPS BUTYL & DESICCANT FOAM INT. GLASS ALUMINUM REINFORCEMENT 5/16" NOM. EXT. GLASS 3s DURASEAL® SPACER STRUCTURAL SILICONE FOAM WITH DESICCANT INT. GLASS, HOT -MELT BUTYL 3/16" NOM. EXT. GLASS 37 SUPER SPACER® NXTTM POLYI BUTYLE SE ROLL -FORME STAINLESS STEE INT. GLASS T FILL AREA 5/16" NOM. LICONE SEAL `EXT. GLASS 39 XL EDGE TM SPACER 1-3/16" I.G. 1-3/16" I.G. GLASS STACK 9/16" LAMINATED GLASS STACK _ _ 9/16" LAMINATED EXTERIOR GLASS STACK GLASS STACK EXTERIOR a7/16" AIRSPACE 1/4" HEAT- STRENGTHENED a 7/16" AIRSPACE 1/4" HEAT - STRENGTHENED 1/4" TEMPERED 0 GLASS 1/4" TEMPERED GLASS GLASS .090" PVB GLASS .090" SGP 42 INTERIOR 42 INTERIOR 1 3/4" GLASS 3/4" GLASS BITE 41 40 BITE 41 40 47 SEE NOTE 42 BELOW GLASS TYPE E1 SEE NOTE 42 BELOW GLASS TYPE F1 NOTE: FOR REVERSED -GLAZING (E1 & F1), ENTIRE PERIMETER OF GLASS EDGE TO HAVE BACKBEDDING. FOR CLARITY, SETTING BLOCKS ARE NOT SHOWN. * ff No. Q� STX C A. LYNN P P.EJ ill//// i INSF .``�� i8705 k a//2G1 r` 'E OF RID N��� Al- \ \\\�� 91LLER, P.E. 58705 FOR CURVED C HEADERS, C1 MAY BE WI 50 ASSEMBLY DETAILS ALL DETAILS SHOWN FROM THE EXTERIOR Z� FOR CLARITY, �HORI EXTERIOR 5.000" .969" 1.993" 1.000" 4.192" .125" .094" TT2.750" 4 .094" 094" 1.750" .454" O1 FRAME HEAD, 2 GLAZING SILL & JAMB O ADAPTER 4.192" .094" FLAT 342" 3 SNAP rOVFR NBLE 10: 2.908" 1.121" .062" 05 BEADING A 4.798" .094" 1.653" OANCHOR CHANNEL 2.185" �{ � 1.462" 1.121" .062" "r7 062" - I�- 60 BEADING B O BENDABLE BEADING 5.000" .969" 1.993" 1.000" .094" .094" 1.750"' OBENDABLE FRAME HEAD & JAMB Item CGI Part # Description Material 1 CGIC-001 FRAME HEAD, JAMB & SILL ALUM. (6063-T6) 2 CGIC-002 POCKET FILLER ALUM. (6063-T6) 3 CGIC-003 FLAT SNAP COVER ALUM. (6063-T6) 4 CGIC-008 ALUMINUM REINFORCEMENT ALUM. (6063-T6) 5 CGIC-004 GLASS STOP "A" ALUM. (6063-T6) 6 CGIC-005 GLASS STOP "B" ALUM. (6063-T6) 8 MISC-087 ANCHOR CHANNEL ALUM. (6063-T6) 9 ARCH-079 FRAME HEAD & JAMB (BENDABLE) ALUM. (6063-T6) 10 CGIC-009 STEEL REINFORCEMENT C. STEEL (A-36) 30 MISC-127 SETTING BLOCK 3/16" X 7/16"X 4", DURO=85 ±5 EPDM 31 MISC-128 IG SETTING BLOCK 3/16" X 1-3/32" X 4", DURO=85 ±5 EPDM 36 KOMMERLING KODISPACE 4SG TIPS SPACER SYSTEM SEE SHEET 15 FOR MATERIALS 37 QUANEX SUPER SPACER NXT WITH HOT MELT BUTYL 38 QUANEX DURASEAL 39 CARDINAL XL EDGE SPACER 40 GSKT-190 GLAZING GASKET, GLASS STOP, DURO=65 ±5 EPDM 41 GSKT-007 GLAZING GASKET, GLAZING LEG, DURO=80 ±5 SANTOPRENE 42 SILC-131/132 SILICONE BACKBEADING: DOW791,983,995, GE7700 50 1 SCRW-010 #12X1-1/2" HEX WASHER SCREW (ASSEMBLY) STAINLESS STEEL NOTES: 1. PARTS 11-29, 32-35, & 43-49 ARE NOT USED AND ARE NOT PART OF THIS APPROVAL. 2. SEE SHEET 11 FOR PARTS 4 & 10. ♦♦♦ ONY LYNN �,• �21 No. 58705 • VJ Q ' STATE OF ��sS.F[ORIDP`. !ONA� 0 �♦♦. A. LYNN MILLER, P.E. P.E.# 58705