Loading...
HomeMy WebLinkAboutMobile Home Permit WorksheetMobile Home Permit Worksheet Application Number: Date: Installer: EDDIE GRUNDEL License # IH1118467 Address of home being installed i PAD Ca�,.T�N �d Manufacturer JACOBSEN Length x width & NOTE. if home is a single wide rill out one half of the blockinq plan if home is a triple or quad wide sketch in remainder of home I understand Lateral Arm Systems cannot be used on any home (new or used) where the sidewall ties exceed 5 ft 4 in. Installer's initials EG Typical p6' spacingI lateral Show locations of Longitudinal and Lateral Systems longltudlnal (use dark lines to show these locations) ;... ---i I---------------------- ------------------------------- --- -------------------- --... i---- marriage wall piers within T of end of home pe Rule 15C New Home Q Used Home Home installed to the Manufacturer's Installation Manual Home is installed in accordance with Rule 15-C Single wide R Wind Zone II Wind Zone III Double wide r_71 Installation Decal # TBD Triple/Quad Serial # TBD PIER SPACING TABLE FOR USED HOMES Load bearing capacity Footer size (sq in) 16" x 16" (256) 18 1/2" x 18 1/2" (342) 20" x 20" (400) 22" x 22" (484)' 24" X 24" (576)' 26" x 26" (676) 1000 psf 3' 4 5' 6 8' 1500 pst 4' 6" 6' 7' 8' 8' 8' 2000 psf 6' 8' 8 2500 psf T 6" 8' 8' 8' 8. 8' 3000 pst 8' 8' 8' 8 8' 8' 3500 pst 1 8' 8' 8' 8' 1 8' 8' Interpolatea from KUIe 1 bG- I pier spacing IaDle. PIER PAD SIZES I-beam pier pad size 17X22.5 Perimeter pier pad size 16X16 Other pier pad sizes (required by the mfq.) Draw the approximate locations of marriage wall openings 4 foot or greater. Use this symbol to show the piers. List all marriage wall openings greater than 4 foot and their pier pad sizes below. Opening Pier pad size 1-4 17X22.5 2-3, POPULAR PAD SIZES Pad Size Sq In 16x16 256 16 x 18 288 18.5 x 18.5 342 16 x 22.5 360 17 x 22 374 13 1 x 26 348 20 x 20 400 17 316x25316 441 17 1/2 x 25 1 2 446 24 x 24 576 26 x 26 676 ANCHORS 4ft —1/_5ft— — FRAME TIES within 2' of end of hc--- spaced at 5' 4" oc _ — TIEDOWN COMPONENTS OTHER TIES Number 23X31 Longitudinal Stabilizinq Device (LSD) Sidewall Manufacturer OLIVER Longitudinal Longitudinal Stabilizinq Device w/Lateral Arms Marriage wall Manufacturer Shearwall Page 1 of 2 Mobile Home Permit Worksheet Application Number: Date: POCKET PENETROMETER TEST The pocket penetrometer tests are rounded down to 1500 psf or check here to declare 1000 lb. soil without testing. X 1,500 X 1,500 X 1,500 POCKET PENETROMETER TESTING METHOD 1. Test the perimeter of the home at 6 locations. 2. Take the reading at the depth of the footer. 3. Usinq 500 lb. increments, take the lowest reading and round down to that increment. X 1,500 X 1,500 X 1,500 TORQUE PROBE TEST The results of the torque probe test is 290 inch pounds or check here if you are declaring 5' anchors without testing . A test showing 275 inch pounds or less will require 5 foot anchors. Note: A state approved lateral arm system is being used and 4 ft. anchors are allowed at the sidewall locations. I understand 5 ft anchors are required at all centerline tie points where the torque test reading is 275 or less and where the mobile home manufacturer may requires anchors with 4000 lb holding capacity. Installer's initials ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER Installer Name EDDIE GRUNDEL Date Tested Electrical Connect electrical conductors between multi -wide units, but not to the main power source. This includes the bonding wire between mutt -wide units. Pg. Plumbing Connect all sewer drains to an existing sewer tap or septic tank. Pg. Site Preparation Debris and organic material removed X Water drainage: Natural Swale Pad X Other Fastening multi wide units Floor: Type Fastener: LAG Length: 6" Spacing: 24" Walls: Type Fastener: LAG Length: 6" Spacing: 24" Roof: Type Fastener: GALV Length: CONT Spacing: 24,, For used homes a min. 30 gauge, 8" wide, galvanized metal strip will be centered over the peak of the roof and fastened with galy. roofing nails at 2" on center on both sides of the centerline. Gasket (weatherproofing requirement) I understand a properly installed gasket is a requirement of all new and used homes and that condensation, mold, meldew and buckled marriage walls are a result of a poorly installed or no gasket being installed. I understand a strip of tape will not serve as a gasket. Installer's initials Type gasket FACTORY FOAM Installed: Pg. Between Floors Yes X Between Walls Yes X Bottom of ridgebeam Yes X Weatherproofing The bottomboard will be repaired and/or taped. Yes X . Pg. Sidinq on units is installed to manufacturer's specifications. Yes x Fireplace chimney installed so as not to allow intrusion of rain water. Yes X Miscellaneous Skirting to be installed. Yes X No Dryer vent installed outside of skirting. Yes X N/A Range downflow vent installed outside of skirting. Yes X N/A Drain lines supported at 4 foot intervals. Yes X Electrical crossovers protected. Yes X Other : Installer verifies all information given with this permit worksheet is accurate and true based on the manufacturer's installation instructions and or Rule 15C-1 & 2 Connect all potable water supply piping to an existing water meter, water tap, or other Installer Signature independent water supply systems. Pg. Paqe 2 of 2 Date