HomeMy WebLinkAboutEngineering � ,c)
CHARETTE INTERNATIONAL ARCHITECTURE
AA 26002424 AR 0016279 NCARB#50462
Jan. 10,2022
TO: Port St Lucie Co Building Dept. RECEIVED
CONTRACTOR: JAN 10 2022
Southeast General Contracting St.Lucie county
10380 sw village Center#232 Permitting
Port St Lucie FL
PERMIT#2008-0279
Charette
633 SE Hidden River Dr
Port St Luice, FL 34983
Truss connection directive
DEAR SIRS:
THIS OFFICE HAS PREFORMED SITE VISITS AND DIRECTED THE FOLLOWING TRUSS
CONNECTIONS PER THE JOB SITE CONDITIONS
#1. TRUSS A2G SHALL SIT ON 2-2 X 6 LEDGERS WITH 2 5/8"WA 5"EMBED AND STRAPPED WITH
2-MTS 18 PER THE CONNECTION CHART. "
#2. TRUSS A6 AND A7 SHALL SIT ON A LEDGER LAGED TO A2G WITH 2-1/2"LAGS AND
STRAPPED WITH MTS 18 EACH TRUSS.
I PAUL CHARETTE,ARCHITECT HEREBYATTEST THAT THE DIRECTIVES STRUCTURALLY SOUND
AND THEY ARE ALL IN COMPLIANCE WITH THE APPROVED CONSTRUCTION PLANS,AND THE
FLORIDA BUILDING CODE 2020,7 TH EDITION.
Should you have any further questions please do not hesitate to contact the office.
p " Digitally
Sineir I1.signed by
Paul
Charette
PaCQhhr ''1 'Date:
,,�2022.01::1�0'
AY
evt.i a 10:03:13
-05'00'
2528 N 38 th Ave.Hollywood F133021 - 561-756-6094 - CIARCHITECTURE@YAHOO.COM