Loading...
HomeMy WebLinkAboutCompaction Test UES Project No: 3310.2100412.0000 Workorder No: 252585-1 Report Date: 12/06/2021 607 Northwest Commodity Cove,Port St.Lucie,FL 34986 -P:772-924-3575 -F:772-924-3580 In-Place Density Test Report Client: Williams Construction UES Technician: Mark Rogers 2306 N 49th St. Date Tested: 11/23/2021 Fort Pierce, FL 34946 Project: CMT Williams Construction Various Locations,TBD County, FL Type of Test: Area Tested: 4906 Matanza Ave, Ft. Pierce-House Field: ASTM D-6938 Nuclear Gauge Method Pad Material: Backfill Laboratory: ASTM D1557 Modified Proctor Reference Datum: 0=Top of Fill The tests below meet the 95%minimum compaction requirement. Maximum Optimum Field Dry Field Soil Pass Test Density Moisture Density Moisture Compaction or No. Location of Test Range (pcf) (%) (pcf) (%) (%) Fail 1 Northeast corner of pad 0-1 ft 115.1 12.2 112.3 11.7 98 Pass 2 Southwest comer of pad 0-1 ft 115.1 12.2 111.7 11.7 97 Pass 3 Center of pad 0-1 ft 115.1 12.2 111.9 11.6 97 Pass Remarks: Permit:2103-0734 Reviewed By GFA International,Inc FBPE Registry No.4930 �..� :.;�tiNSF.. Digitally signed by Q:r No. 92555 �" Alexander Albandoz a+: :. 9'. �TA7E OF 'fu Date:2021.12.06 O��`•••.......OR1 Op'�j��:� 12:58:39-05'00' •'SSiON A�E„`O, Alex Albandoz,P.E. STATE OF FLORIDA Professional Engineer No.92555 This item has been digitally signed and sealed by Alex Albandoz, P.E.on the date adjacent to the seal.Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. P�G0'v�P G`eG S�\6\e." og To establish a mutual protection to Universal's clients,the Public and ourselves,all reports are submitted as confidential property of our clients and authorization for publication of statements,conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1