HomeMy WebLinkAboutCompaction Test UES Project No: 3310.2100412.0000
Workorder No: 252585-1
Report Date: 12/06/2021
607 Northwest Commodity Cove,Port St.Lucie,FL 34986 -P:772-924-3575 -F:772-924-3580
In-Place Density Test Report
Client: Williams Construction UES Technician: Mark Rogers
2306 N 49th St. Date Tested: 11/23/2021
Fort Pierce, FL 34946
Project: CMT Williams Construction
Various Locations,TBD County, FL
Type of Test:
Area Tested: 4906 Matanza Ave, Ft. Pierce-House Field: ASTM D-6938 Nuclear Gauge Method
Pad
Material: Backfill Laboratory: ASTM D1557 Modified Proctor
Reference Datum: 0=Top of Fill
The tests below meet the 95%minimum compaction requirement.
Maximum Optimum Field Dry Field Soil Pass
Test Density Moisture Density Moisture Compaction or
No. Location of Test Range (pcf) (%) (pcf) (%) (%) Fail
1 Northeast corner of pad 0-1 ft 115.1 12.2 112.3 11.7 98 Pass
2 Southwest comer of pad 0-1 ft 115.1 12.2 111.7 11.7 97 Pass
3 Center of pad 0-1 ft 115.1 12.2 111.9 11.6 97 Pass
Remarks: Permit:2103-0734
Reviewed By
GFA International,Inc
FBPE Registry No.4930
�..� :.;�tiNSF.. Digitally signed by
Q:r No. 92555 �" Alexander Albandoz
a+: :.
9'. �TA7E OF 'fu Date:2021.12.06
O��`•••.......OR1 Op'�j��:� 12:58:39-05'00'
•'SSiON A�E„`O,
Alex Albandoz,P.E.
STATE OF FLORIDA
Professional Engineer No.92555
This item has been digitally signed and sealed by Alex Albandoz,
P.E.on the date adjacent to the seal.Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.
P�G0'v�P
G`eG
S�\6\e."
og
To establish a mutual protection to Universal's clients,the Public and ourselves,all reports are submitted as confidential property of our clients and
authorization for publication of statements,conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1