Loading...
HomeMy WebLinkAboutCertification Design Load ComplianceL^v,C1_ .� Planning & Development Services Department �14 Building & Code Regulations Division _..�� _,� v ,pro �..� 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1577 Certification for Design Load Compliance Bch Edition Project Name: New Residence for Ryan & Shannyn Reed Project Address: Sneed Road Fort Pierce Florida Permit#: Occupancy Type: R3 Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • If submitting hard copy, submit (2) copies with all pertinent information. St Lucie Fire District requires a digitally signed electronic version. • If submitting electronically, form should be uploaded into Bluebeam. Separate submission to Fire is still required • All digital files must be in an unlocked Portable Document Format (PDF) version * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2020 Building Code 7th Edition using ASCE 7-16 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 160 Ult. mph 0.6 ASD 1.0 LRFD End Zone Width: 7.6 ft S. Mean Roof Height 19.5 ft Roof Pitch: 6 :12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: +35.4 -38.4 +35.4 -47.4 +30.1-38.3 Zone 4: Zone 5: Garage: 6a. Roofs Maximum +/- pressures: + +26.4 psf _ -65A psf Or define individual zones on the plans (+ 10 non-Conc.) 7. Design Loads: Floor: PSF Roof -Dead: 17 PSF Roof -Live: 20 Balcony+/- PSF Dock: PSF Deck: PSF Stairs: PSF .Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Please Explain: , 9. Is a Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes No Assumed DESIGN PROFESSIONAL CERTIFICATION STATEMENT: By Builder to code at site -prep I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the current Florida Building Code as adopted. Digitally S'i°gned by S. I S. James Studebaker PE 47695 CA 33421 i a -Print Name Cent # & Co. CertofAuthorizatian Date: 2021 1 3:05.5,9 _05 '00+ ' Studebaker Engineering Services Revised 3/25"/�021 Company Name & Address