Certification for Design Load Compliance
Bch Edition
Project Name: New Residence for Ryan & Shannyn Reed
Project Address: Sneed Road Fort Pierce Florida
Permit#: Occupancy Type: R3 Construction Type: V
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• If submitting hard copy, submit (2) copies with all pertinent information. St Lucie Fire District requires a digitally
signed electronic version.
• If submitting electronically, form should be uploaded into Bluebeam. Separate submission to Fire is still required
• All digital files must be in an unlocked Portable Document Format (PDF) version
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2020 Building Code 7th Edition using ASCE 7-16
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 160 Ult. mph 0.6 ASD 1.0 LRFD End Zone Width: 7.6 ft
S. Mean Roof Height 19.5 ft Roof Pitch: 6 :12 Parapet: n/a ft
6. Components & Cladding Design Pressures Used:
+35.4 -38.4 +35.4 -47.4 +30.1-38.3
Zone 4: Zone 5: Garage:
6a. Roofs
Maximum +/- pressures: + +26.4 psf _ -65A psf Or define individual zones on the plans
(+ 10 non-Conc.)
7. Design Loads: Floor: PSF Roof -Dead: 17 PSF Roof -Live: 20 Balcony+/- PSF
Dock: PSF Deck: PSF Stairs: PSF .Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Please Explain: ,
9. Is a Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes No Assumed
DESIGN PROFESSIONAL CERTIFICATION STATEMENT: By Builder to code at site -prep
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the current Florida Building Code as adopted.
Digitally S'i°gned by S.
I S. James Studebaker PE 47695 CA 33421
i a -Print Name Cent # & Co. CertofAuthorizatian
Date: 2021
1 3:05.5,9 _05 '00+ ' Studebaker Engineering Services
Revised 3/25"/�021 Company Name & Address