HomeMy WebLinkAboutEnergy Efficiency Code9
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation -Residential Performance Method
Project Name: REED RESIDENCE
Builder Name:
Street: SNEED ROAD
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: RYAN AND SHANNYN REED
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall Typ02900.0 sgft.)
Insulation Area
2, Single family or multiple family
Detached
a. Concrete Block.- Int Insul, Exterior
R=5.0 2680.00 ft2
b. Concrete Block - Int Insul, Adjacent
R=5.0 220.00 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft2
11. Ceiling Types (4070.0 sgft.)
Insulation Area
5. Is this a worst case?
No
a. Roof Deck (Unvented)
R=20.0 4070.00 ft2
6. Conditioned floor area above grade (ft2)
4070
b. NIA
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
7. Windows(533.3 sgft.) Description
Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ft2
6 200
a. U-Factor. Sgl, U=1.05
533.33 ft2
b. Sup: Attic, Ret: Attic, AH: Attic
6 130
SHGC: SHGC=0.25
b. U-Factor. N/A
ft2
13. Cooling systems .
kBtu/hr, Efficiency
SHGC:
a. Central Unit
48.0 SEER:17.00
c. U-Factor. N/A
ft2
b. Central Unit
25.0 SEERA7.00
SHGC:
Area Weighted Average Overhang Depth:
12.328 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.250
a. Electric Strip Heat
b. Electric Strip Heat
34.0 COP:1.00
17.0 COP:1.00
8. Skylights
Area
c. U-Factor.(AVG) N/A
ft2
15. Hot water systems
F SHGC(AVG): N/A
a. Propane Tankless
Cap: 1 gallons
i poor Types (4070.0 sgft.)
Insulation Area
EF: 0.800
a. Slab -On -Grade Edge Insulation
R=0.0 4070.00 ft2
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
16. Credits
None .
Total Proposed Modified Loads: 101.99
PASS
GlasslFloor Area: 0.131
Total Baseline Loads: 103.87
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY0-,
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.. '
OWNER/AGENT:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code. -
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1, g>®R
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accorda t 'R4 1. anNyl, project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACV�C�9�
_ � gCOU14TYof
7/912021 9:57 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7
' � wrwAwT
FORM R405-2020
INVU I ,unfinflAMT %onr-t,.nL-101 r«rvR r
PROJECT.
Title:
REED RESIDENCE
Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 4070
Lot #
(---'liner Name:
RYAN AND SHANNYN REED
Total Stories: 1
Block/Subdivision:
.. of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
SNEED ROAD
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County.
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Family Type:
Detached
FL,
New/E)asting:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating Design Daily Temp
Design Location
TMY Site
97,5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH_MUNI' 39
90
70
75
299
62
Low
BLOCKS
Number
Name
. Area
Volume
1
AHU 1
2752
22016
2
AHU 2
1318
10544
SPACES.
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
CABANA BATH
66
528 No
0
1
Yes
Yes
Yes
-2
SILLARDS
272
2176 No
0
1
Yes
Yes
Yes
3
HALLWAY
135
1080 No
0
1
No
Yes
Yes
4
BEDROOM 3
218
1744 No
0
1
1
Yes
Yes
Yes
5
WIC 3
36
288 No
0
1
Yes
Yes
Yes
6
BATH 3
60
480 No
0
1
No
Yes
Yes
7
MUD ROOM
88
704 No
0
1
Yes
Yes
Yes
8
BEDROOM 2
213
1704 No
0
i
1'
Yes
Yes
Yes
9
BATH 2
60
480 No
0
1
No
Yes
Yes
10
WIC 2
36
288 No
0
1
Yes
Yes
Yes
11
HALL
32
256 No
0
1
Yes
Yes
Yes
12
PANTRY
42
336 No
0
1
No
Yes
Yes
13
LAUNDRY RM
132
1056 No
0
1
No
Yes
Yes
14
FOYER
192
1536.No
0
1
Yes
Yes
Yes
15
KITCHENIDINING
550
4400 Yes
0
1
Yes
Yes
. Yes
16
GREAT RM
620
4960 No
0
1
Yes
Yes
Yes
17
MASTER BEDROO
531
4248 No
b ,
1
1
Yes
Yes
Yes
18
M W IC
70
560 No
0
1
Yes
Yes
Yes
19
M WIC 2
49
392 No
0
1
No
Yes
Yes
20
M HALL
20
160 No
0
1
No
Yes
Yes
91
M BATH
212
1696 No
0
1
Yes
Yes
Yes
7/9/2021 9:57 AM. EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7
F=nRnn Ran_,;_gngn INP11T RUMMARY CHECKLIST REPORT
SPACES
Number Name Area Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
22 M TOILET 36
288
No 0
1 Yes
Yes
Yes
f-
�23
! OFFICE 400 3200
No 0
1 Yes
Yes
Yes
FLOORS
4 Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
CABANA BATH
12 ft
66 ft'
____ 1
0
0
2 Slab -On -Grade Edge Insulation
BILLARDS
21 ft
272 ft'
____ 1
0
0
3 Slab -On -Grade Edge Insulation
HALLWAY
1 ft
135 ft'
____ 1
0
0
4 Slab -On -Grade Edge Insulation
BEDROOM 3
29 ft
218 ft'
1
0
0
5 Slab -On -Grade Edge Insulation
WIC 3
6 ft
36 ft'
___ 1
0
0
6 Slab -On -Grade Edge Insulation
BATH 3
1 ft
60 ft'
___ , 1
0
0
7 Slab -On -Grade Edge Insulation
MUD ROOM
1 ft
88 ft'
____ 1
0
0
8 Slab -On -Grade Edge Insulation
BEDROOM 2
14 ft
213 ft'
1
0
0
9 Slab -On -Grade Edge Insulation
BATH 2
1 ft
60 ft'
___ 1
0
0
10SIab-On-Grade Edge Insulation
WIC 2
6 ft
36 ft'
____ 1
0
0
11Slab-On-Grade Edge Insulation
HALL
8 ft
32 f.?
___ 1
0
0
12SIab-On-Grade Edge Insulation
PANTRY
1 ft
42 ft'
____ 1
0
0
13SIab-On-Grade Edge Insulation
LAUNDRY RM
1 ft
132 ft'
___ 1
0
0
14SIab-On-Grade Edge Insulation
FOYER
12 ft
192 ft'
1
0
0
15SIab-On-Grade Edge Insulation
KITCHENIDININ
28 ft
550 ft'
1
0
0
16SSIab-On-Grade Edge Insulation
GREAT RM
20 ft
620 ft'
___ 1
0
0
17SIab-On-Grade Edge Insulation
MASTER BEDRO
44 ft
531 ft'
0
0
18SIab-On-Grade Edge Insulation
M WIC
loft
70 ft'
____ 1
0
0
19SIab-On-Grade Edge Insulation
M W IC 2
1 ft
49 ft'
--- 1
0
0
20SIab-On-6rade Edge Insulation
M HALL
1 ft
20 ft'
1
0
0
21SIab-On-Grade Edge Insulation
M BATH
29 ft
212 ft'
___ 1
0
0
22SIab-On-Grade Edge Insulation
M TOILET
4 ft
36 ft'
__ 1
0
0
23SIab-On-Grade Edge Insulation
OFFICE
24 ft
400 ft'
____ 1
0
0
7/9/2021 9:57 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INF'U I SUMMAKT Vr11tUr%L10 I M=rUR I
ROOF
/
Roof
Gable
Roof Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color, Ban-
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 4551 ft'
0 ft'
Light N
.'0.3
No 0.9
No 20
26.57
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC .
1
Full attic Unvented
0
4070 ft'
N
N "
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) CABANA BATH
0
Blown,
66 ft'
0.1
Wood
2
Under Attic (Unvented) BILLARDS
0
Blown
272 ft'
0.1
Wood
3
Under Attic (Unvented) HALLWAY
0
Blown
135 ft'
0.1
Wood
4
Under Attic (Unvented) BEDROOM 3
0
Blown
218 ft'
0.1
Wood
5
Under Attic (Unvented) WIC 3
0
Blown
36 ft'
0.1
Wood
6
Under Attic (Unvented) BATH 3
0
Blown
60 ft'
0A
Wood
7
Under Attic (Unvented) MUD ROOM
0
Blown
88 ft'
0.1
Wood
8
Under Attic (Unvented) BEDROOM 2
0
Blown
213 ft'
0A
Wood
9
Under Attic (Unvented) BATH 2
0
Blown
60 ft'
0.1
Wood
10
Under Attic (Unvented) WIC 2
0
Blown
36 ft'
0.1
Wood
11
Under Attic (Unvented) HALL
0
Blown
32 ft'
0.1
Wood
12
Under Attic (Unvented) PANTRY
'0
Blown
42 ft'
0.1
Wood
(
13
Under Attic (Unvented) LAUNDRY RM
0
Blown
132 ft'
0.1
Wood
14
Under -Attic (Unvented) FOYER
0
Blown
192 ft'
-0.1
Wood
15
Under Attic (Unvented) KITCHEN/DININ
0
Blown
550 W
0.1
Wood
16
Under Attic (Unvented) GREATRM
0
Blown
620ft'
0.1
Wood
17
Under Attic (Unvented) MASTER BEDRO 0
Blown
531 ft'
0.1'
Wood
18
Under Attic (Unvented) MWIC
0
Blown
70ft'
0.1
Wood
19
Under Attic (Unvented) MWIC 2
0
Blown
49 ft'
0.1
Wood
20
Under Attic (Unvented) M HALL
0
Blown
20 ft'
0.1
Wood ..
21
Under Attic (Unvented) M BATH
0
Blown
212 W
0.1
Wood
22
Under Attic (Unvented) M TOILET
0
Blown
36 ft'
0.1
Wood
23
Under Attic (Unvented) OFFICE
0
Blown
400ft'
0.1
Wood
WALLS
Adjacent
Cavity , Width Height
Sheathing Framing Solar
Below
Space
0
_ 1
W
Exterior Concrete Block - Int InsuxABANA BAT
5 6
0 W 0
60.0 ft'
0
0 0.3
0
_ 2
S
Exterior Concrete Block - Int InsLXABANA BAT
5 6
0 10 0
60.0 ft'
0
0 0.3
0
_ 3
W
Exterior Concrete Block - Int Insul BILLARDS
.5 17
0 10 0
170.0 ft'
0
0 0.3
0
_ 4
N
Exterior Concrete Block - Int Insul BILLARDS
5 4
0 10 0
40.0 ft'
0
0 0.3
0
_ 5
S
Exterior Concrete Block - Int InsuBEDR00M 3
5 14
0 10 0
140.0 ft'
0
0 0.3
0
6
j
W
Exterior Concrete Block - Int InsuBEDR00M 3
5 15
0 10 0
150.0 ft'
0
0 0.3
0
7/9/2021 9:57 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020
INPU I bUMMAKT I MCrUM i
WALLS . .
Adjacent
Cavity
Width
Height
Sheathing
Framing
Solar
Below
Space
L.
Et In
Ef
In
Er
Abs
0
7
W
Exterior
pop
Concrete Block - Int Insul WIC 3
5
6
0 10
0
60.0 ft'
0
0
0.3.
0
_ 8
S
Exterior
Concrete Block - Int InsuMUD ROOM
5
1
0 10
0
10.0 ft'
0
0
0.3
0
9
S
Garage
Concrete Block - Int InsuMUD ROOM
5
7
0 10
0
70.0 ft'
0
0
0.3
0
_ 10
E
Exterior
Concrete Block - Int InsuBEDROOM 2
5
14
0 10
0
140.0 ft'
0
0
0.3
0
11
S
Garage
Concrete Block - Int InsuBEDR00M 2
5
15
0 10
0
150.0 ft'
0
0
0.3
0
12
E
Exterior
Concrete Block- Int Insul WIC 2
5
6
0 10
.0
60.0 ft'
0
0
0.3
0
13
E
Exterior
Concrete Block - Int Insul HALL
5
8
0 10
0
80.0 ft'
0
0
0.3
0
_
_ 14
W
Exterior
Concrete Block - Int Insul FOYER
5
12
. 0 10
0
120.0 ft'
0
0
0.3
0
_ 15
E
Exterior
Concrete Block - Int InsuKITCHENIDI-
5
16
0 10
0
160.0 ft'
0
0
0.3
0
_ 16
S
Exterior
Concrete Block - Int InsuKITCHEN/DI
5
10
0 10
0
100.0 ft'
0
0
0.3
0
_ 17
N
Exterior
Concrete Block - Int InsuKITCHEN/DI
5-
2
0 10
0
20.0 ft'
0
10 1
0.3
0
_ 18
E
Exterior .
Concrete Block - Int InsuIGREAT RM
5
20
0 10
0
200.0 ft'
0
0
0.3
0
_ 19
E
Exterior
Concrete Block - Int InsuMASTER BE
5
18
0 10
0
180.0 ft'
0
0
0.3
0
_ 20
N
Exterior
Concrete Block - Int InsuMASTER BE
5
26
0 10
0
260.0 ft'
0
0
0.3
0
_ 21
N
Exterior
Concrete Block - Int Insul .M W IC
5
10
0 10
0
100.0 ft'
0
0
0.3
0
_ 22
W
Exterior
Concrete Block - Int Insul M BATH
5
14
0 10
0
140.0 ft'
0
0
0.3
0
_ 23
N
Exterior
Concrete Block -'Int Insul M BATH
5
15
0 10
0
150.0 ft'
0
0
0.3
0
W
Exterior
Concrete Block - Int Insul M TOILET
5
4
0 10
0
40.0 ft'
0
0
0.3
0
_24
_ 25
S
Exterior
Concrete Block - Int Insul OFFICE
5
4
0 10
0
40.0 ft'
0
0
0.3
0
26
W
Exterior
Concrete Block - Int Insul OFFICE
5
20
0 10
0
200.0 ft'
0
0
0.3
0
DOORS
i
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In .
Ft 1n
1
S
Insulated MUD ROOM
None
.23
3
6. 8
20 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
W 1
Metal Low-E Single Yes
1.05
0.25
Y
8.0 ft'
20 ft 0 in
1 ft 4 in
None
None
2
W 3
Metal Low-E Single Yes
1.05
0.25
Y
36.0 ft'
11 ft 4 in
1 ft4 in
None
None
3
W 6
Metal ' ' Low-E Single Yes
1.05
0.25
Y
36.0 ft'
7 ft 4 in
1 ft 4 in
None
None
4
E 10
Metal Low-E Single Yes
1.05
0.25
Y
36.0 ft'
1 ft 4 in
1 ft 4 in
None
None
5
E 13
Metal Low-E Single Yes
1.05
0.25
Y
24.0 ft'
20 ft 0 in
1 ft 4 in
None
None
6
W 14
Metal Low-E Single Yes
1.05
0.25
Y
18.7 ft'
15 ft 4 in
1 ft4 In
None
None
7
W 14
Metal Low-E Single Yes
1.05
0.25
Y
48.0 ft'
15 ft 4 in
1 ft 4 in
None
None
8
E 15
Metal Low-E Single Yes
1.05
0.25
Y
36.0 ft'
14 It 0 in
1 ft 4 in
None
None
9
E 18
Metal Low-E Single Yes
1.05
0.25
Y
32.0 ft'
14 ft 0 in
1 ft 4 in
None
None
10
N 18
Metal Low-E Single Yes
1.05
0.25
Y
48.0 ft'
14 ft 0 in
1 ft 4 in
None
None
11
E 19
Metal Low-E Single Yes
1.05
0.25
Y
32.0 ft'
14 ft 0 in
1 ft 4 in
None
None
12
E 19
Metal Low-E Single Yes
1.05
025
Y
48.0 ft'
14 ft 0 in
1 ft 4 in
None
None
13
N 20
Metal Low-E Single Yes
1.05
0.25.
Y
32.0 ft'
11 ft 4 in
1 ft 4 in
None
None
t
14
N 20
Metal Low-E Single Yes
1.05
0.25
Y
48.0 ft'
11 ft 4 in
1 ft4 in
None
None
7/9/2021 9:57 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7
F=nQnn PAn-_gngn IMPHT RUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation. .
/
#
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1
_ 15
16
17
W 22 Metal Low-E Single
N 23 Metal Low-E Single
W 26 Metal Low-E Single
Yes
Yes
Yes
1.05 0.25 Y 8.0 ft' 7 ft4 in 1 ft4 in , None
1.05 0.25 Y 6.7 ft' 11 ft 4 in 1 ft 4 in None
1.05 0.25 Y 36.0 ft' 11 ft 4 in 1 ft 4 in None
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
950 ft' 950 ft'
23 ft loft 11
INFILTRATION
#
Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1
Wholehouse Proposed ACH(50)
.000254
2713.3 148.86 279.47 .0902 5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
2
Electric Strip Heat]
Electric Strip Heat]
None
None
COPA 34 kBtulhr 1
COPA 17 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit/
Central Unit/
Split
Split
Single SEER: 17 48 kBtu/hr 1440 cfm 0.8 1
Single SEER: 17 25 kBtu/hr 750 cfm 0.8 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Propane Tankless
Exterior ''
0.8 1 gal 55.1 gal 120 deg None
SOLAR HOT WATER SYSTEM.
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft'
DUCTS
#
-- Supply ----
Location R-Value Area
— Return -- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
'Heat. Cool
1
2
Attic 6 200 ft'
Attic 6 130 ft'
Attic
Attic
20 ft' Default Leakage Attic (Default) c(Default) c
13 ft' Default Leakage Attic (Default) c(Default) c
1 1
2 2
7/9/2021 9:57 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat:
N
Ceiling Fans:
Pnolin Jan HFeb
(` sting Jan
Feb
Mar
Mar
Apr
E Pr
f
M
M
Jun
Jun
(� Jul
j Jul
(� Auge
[ t Aug
r 1 Oct (�
[ j Oct [Xj
Nov
Nov
[ Dec
[X] Dec
itin Jan
Feb
Mar
[X] A r
[
May,
[[[ jjj Jun
E ] Jul
((j Aug
Se
[[[XXX]]] Oct [X)
Nov
[ j Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5.
6
7
8
9 10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
80
80
78
78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
80
80
78
78
78
78
78 78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
68
68
Heating(WEH)
AM
65
65
65
65
65
65
65
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft'
0 ft
0.3
CABANA BATH
Default(8 lbs/sq.ft.
ft'
ft
0.3
BILLARDS
Default(8 lbs/sq.ft.
fN
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft'
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft'
ft
0.3 "
WIC 3
Default(8 Ibs/sq.ft.
ft'
ft
0.3
BATH 3
Default(8 Ibslsq.ft.
f?
ft
0.3
MUD ROOM
Default(8 Ibs/sq.ft.
ft'
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft,
ft'
ft
0.3
BATH 2
Default(8 lbs/sq.ft.
f?
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft'
ft
0:3
HALL
Default(8 Ibs/sq.ft,
f?
ft
0.3
PANTRY
Default(8 Ibs/sq.ft•
fe
ft
0.3
LAUNDRY RM
Default(8 Ibs/sq'•ft.
fe
ft
0.3
FOYER
Default(8lbs/sq.ft.
ft'
ft
0.3
KITCHEN/DINING
Default(8 Ibs/sq.ft.
f?
ft
0.3
GREAT RM
Default(8 Ibs/sq.ft.
ft'
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
f?
ft
0.3
M W IC
Default(8 Ibs/sq.ft.
fN
ft
0.3
M W IC 2
Default(8 Ibs/sq.ft.
ft'
ft
0.3
M HALL
Default(8 Ibs/sq.ft.
ft'
ft
0.3
M BATH
D'efault(8 Ibs/sq.ft.
ft'
ft
0.3
M TOILET
Default 8 Ibs/s .ft.
ft' -
ft
0.3.
OFFICE
7/9/2021 9:57 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7