Loading...
HomeMy WebLinkAboutEnergy Efficiency Code9 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation -Residential Performance Method Project Name: REED RESIDENCE Builder Name: Street: SNEED ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: RYAN AND SHANNYN REED Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Typ02900.0 sgft.) Insulation Area 2, Single family or multiple family Detached a. Concrete Block.- Int Insul, Exterior R=5.0 2680.00 ft2 b. Concrete Block - Int Insul, Adjacent R=5.0 220.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Types (4070.0 sgft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 4070.00 ft2 6. Conditioned floor area above grade (ft2) 4070 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(533.3 sgft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 200 a. U-Factor. Sgl, U=1.05 533.33 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 130 SHGC: SHGC=0.25 b. U-Factor. N/A ft2 13. Cooling systems . kBtu/hr, Efficiency SHGC: a. Central Unit 48.0 SEER:17.00 c. U-Factor. N/A ft2 b. Central Unit 25.0 SEERA7.00 SHGC: Area Weighted Average Overhang Depth: 12.328 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat b. Electric Strip Heat 34.0 COP:1.00 17.0 COP:1.00 8. Skylights Area c. U-Factor.(AVG) N/A ft2 15. Hot water systems F SHGC(AVG): N/A a. Propane Tankless Cap: 1 gallons i poor Types (4070.0 sgft.) Insulation Area EF: 0.800 a. Slab -On -Grade Edge Insulation R=0.0 4070.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None . Total Proposed Modified Loads: 101.99 PASS GlasslFloor Area: 0.131 Total Baseline Loads: 103.87 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY0-, DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code.. ' OWNER/AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. - Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1, g>®R - Compliance requires an Air Barrier and Insulation Inspection Checklist in accorda t 'R4 1. anNyl, project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACV�C�9� _ � gCOU14TYof 7/912021 9:57 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7 ' � wrwAwT FORM R405-2020 INVU I ,unfinflAMT %onr-t,.nL-101 r«rvR r PROJECT. Title: REED RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 4070 Lot # (---'liner Name: RYAN AND SHANNYN REED Total Stories: 1 Block/Subdivision: .. of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: SNEED ROAD Permit Office: ST LUCIE COUNTY Cross Ventilation: No County. St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/E)asting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97,5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI' 39 90 70 75 299 62 Low BLOCKS Number Name . Area Volume 1 AHU 1 2752 22016 2 AHU 2 1318 10544 SPACES. Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 CABANA BATH 66 528 No 0 1 Yes Yes Yes -2 SILLARDS 272 2176 No 0 1 Yes Yes Yes 3 HALLWAY 135 1080 No 0 1 No Yes Yes 4 BEDROOM 3 218 1744 No 0 1 1 Yes Yes Yes 5 WIC 3 36 288 No 0 1 Yes Yes Yes 6 BATH 3 60 480 No 0 1 No Yes Yes 7 MUD ROOM 88 704 No 0 1 Yes Yes Yes 8 BEDROOM 2 213 1704 No 0 i 1' Yes Yes Yes 9 BATH 2 60 480 No 0 1 No Yes Yes 10 WIC 2 36 288 No 0 1 Yes Yes Yes 11 HALL 32 256 No 0 1 Yes Yes Yes 12 PANTRY 42 336 No 0 1 No Yes Yes 13 LAUNDRY RM 132 1056 No 0 1 No Yes Yes 14 FOYER 192 1536.No 0 1 Yes Yes Yes 15 KITCHENIDINING 550 4400 Yes 0 1 Yes Yes . Yes 16 GREAT RM 620 4960 No 0 1 Yes Yes Yes 17 MASTER BEDROO 531 4248 No b , 1 1 Yes Yes Yes 18 M W IC 70 560 No 0 1 Yes Yes Yes 19 M WIC 2 49 392 No 0 1 No Yes Yes 20 M HALL 20 160 No 0 1 No Yes Yes 91 M BATH 212 1696 No 0 1 Yes Yes Yes 7/9/2021 9:57 AM. EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7 F=nRnn Ran_,;_gngn INP11T RUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 M TOILET 36 288 No 0 1 Yes Yes Yes f- �23 ! OFFICE 400 3200 No 0 1 Yes Yes Yes FLOORS 4 Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation CABANA BATH 12 ft 66 ft' ____ 1 0 0 2 Slab -On -Grade Edge Insulation BILLARDS 21 ft 272 ft' ____ 1 0 0 3 Slab -On -Grade Edge Insulation HALLWAY 1 ft 135 ft' ____ 1 0 0 4 Slab -On -Grade Edge Insulation BEDROOM 3 29 ft 218 ft' 1 0 0 5 Slab -On -Grade Edge Insulation WIC 3 6 ft 36 ft' ___ 1 0 0 6 Slab -On -Grade Edge Insulation BATH 3 1 ft 60 ft' ___ , 1 0 0 7 Slab -On -Grade Edge Insulation MUD ROOM 1 ft 88 ft' ____ 1 0 0 8 Slab -On -Grade Edge Insulation BEDROOM 2 14 ft 213 ft' 1 0 0 9 Slab -On -Grade Edge Insulation BATH 2 1 ft 60 ft' ___ 1 0 0 10SIab-On-Grade Edge Insulation WIC 2 6 ft 36 ft' ____ 1 0 0 11Slab-On-Grade Edge Insulation HALL 8 ft 32 f.? ___ 1 0 0 12SIab-On-Grade Edge Insulation PANTRY 1 ft 42 ft' ____ 1 0 0 13SIab-On-Grade Edge Insulation LAUNDRY RM 1 ft 132 ft' ___ 1 0 0 14SIab-On-Grade Edge Insulation FOYER 12 ft 192 ft' 1 0 0 15SIab-On-Grade Edge Insulation KITCHENIDININ 28 ft 550 ft' 1 0 0 16SSIab-On-Grade Edge Insulation GREAT RM 20 ft 620 ft' ___ 1 0 0 17SIab-On-Grade Edge Insulation MASTER BEDRO 44 ft 531 ft' 0 0 18SIab-On-Grade Edge Insulation M WIC loft 70 ft' ____ 1 0 0 19SIab-On-Grade Edge Insulation M W IC 2 1 ft 49 ft' --- 1 0 0 20SIab-On-6rade Edge Insulation M HALL 1 ft 20 ft' 1 0 0 21SIab-On-Grade Edge Insulation M BATH 29 ft 212 ft' ___ 1 0 0 22SIab-On-Grade Edge Insulation M TOILET 4 ft 36 ft' __ 1 0 0 23SIab-On-Grade Edge Insulation OFFICE 24 ft 400 ft' ____ 1 0 0 7/9/2021 9:57 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INF'U I SUMMAKT Vr11tUr%L10 I M=rUR I ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color, Ban- Absor. Tested Tested Insul. (deg) 1 Hip Metal 4551 ft' 0 ft' Light N .'0.3 No 0.9 No 20 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC . 1 Full attic Unvented 0 4070 ft' N N " CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) CABANA BATH 0 Blown, 66 ft' 0.1 Wood 2 Under Attic (Unvented) BILLARDS 0 Blown 272 ft' 0.1 Wood 3 Under Attic (Unvented) HALLWAY 0 Blown 135 ft' 0.1 Wood 4 Under Attic (Unvented) BEDROOM 3 0 Blown 218 ft' 0.1 Wood 5 Under Attic (Unvented) WIC 3 0 Blown 36 ft' 0.1 Wood 6 Under Attic (Unvented) BATH 3 0 Blown 60 ft' 0A Wood 7 Under Attic (Unvented) MUD ROOM 0 Blown 88 ft' 0.1 Wood 8 Under Attic (Unvented) BEDROOM 2 0 Blown 213 ft' 0A Wood 9 Under Attic (Unvented) BATH 2 0 Blown 60 ft' 0.1 Wood 10 Under Attic (Unvented) WIC 2 0 Blown 36 ft' 0.1 Wood 11 Under Attic (Unvented) HALL 0 Blown 32 ft' 0.1 Wood 12 Under Attic (Unvented) PANTRY '0 Blown 42 ft' 0.1 Wood ( 13 Under Attic (Unvented) LAUNDRY RM 0 Blown 132 ft' 0.1 Wood 14 Under -Attic (Unvented) FOYER 0 Blown 192 ft' -0.1 Wood 15 Under Attic (Unvented) KITCHEN/DININ 0 Blown 550 W 0.1 Wood 16 Under Attic (Unvented) GREATRM 0 Blown 620ft' 0.1 Wood 17 Under Attic (Unvented) MASTER BEDRO 0 Blown 531 ft' 0.1' Wood 18 Under Attic (Unvented) MWIC 0 Blown 70ft' 0.1 Wood 19 Under Attic (Unvented) MWIC 2 0 Blown 49 ft' 0.1 Wood 20 Under Attic (Unvented) M HALL 0 Blown 20 ft' 0.1 Wood .. 21 Under Attic (Unvented) M BATH 0 Blown 212 W 0.1 Wood 22 Under Attic (Unvented) M TOILET 0 Blown 36 ft' 0.1 Wood 23 Under Attic (Unvented) OFFICE 0 Blown 400ft' 0.1 Wood WALLS Adjacent Cavity , Width Height Sheathing Framing Solar Below Space 0 _ 1 W Exterior Concrete Block - Int InsuxABANA BAT 5 6 0 W 0 60.0 ft' 0 0 0.3 0 _ 2 S Exterior Concrete Block - Int InsLXABANA BAT 5 6 0 10 0 60.0 ft' 0 0 0.3 0 _ 3 W Exterior Concrete Block - Int Insul BILLARDS .5 17 0 10 0 170.0 ft' 0 0 0.3 0 _ 4 N Exterior Concrete Block - Int Insul BILLARDS 5 4 0 10 0 40.0 ft' 0 0 0.3 0 _ 5 S Exterior Concrete Block - Int InsuBEDR00M 3 5 14 0 10 0 140.0 ft' 0 0 0.3 0 6 j W Exterior Concrete Block - Int InsuBEDR00M 3 5 15 0 10 0 150.0 ft' 0 0 0.3 0 7/9/2021 9:57 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPU I bUMMAKT I MCrUM i WALLS . . Adjacent Cavity Width Height Sheathing Framing Solar Below Space L. Et In Ef In Er Abs 0 7 W Exterior pop Concrete Block - Int Insul WIC 3 5 6 0 10 0 60.0 ft' 0 0 0.3. 0 _ 8 S Exterior Concrete Block - Int InsuMUD ROOM 5 1 0 10 0 10.0 ft' 0 0 0.3 0 9 S Garage Concrete Block - Int InsuMUD ROOM 5 7 0 10 0 70.0 ft' 0 0 0.3 0 _ 10 E Exterior Concrete Block - Int InsuBEDROOM 2 5 14 0 10 0 140.0 ft' 0 0 0.3 0 11 S Garage Concrete Block - Int InsuBEDR00M 2 5 15 0 10 0 150.0 ft' 0 0 0.3 0 12 E Exterior Concrete Block- Int Insul WIC 2 5 6 0 10 .0 60.0 ft' 0 0 0.3 0 13 E Exterior Concrete Block - Int Insul HALL 5 8 0 10 0 80.0 ft' 0 0 0.3 0 _ _ 14 W Exterior Concrete Block - Int Insul FOYER 5 12 . 0 10 0 120.0 ft' 0 0 0.3 0 _ 15 E Exterior Concrete Block - Int InsuKITCHENIDI- 5 16 0 10 0 160.0 ft' 0 0 0.3 0 _ 16 S Exterior Concrete Block - Int InsuKITCHEN/DI 5 10 0 10 0 100.0 ft' 0 0 0.3 0 _ 17 N Exterior Concrete Block - Int InsuKITCHEN/DI 5- 2 0 10 0 20.0 ft' 0 10 1 0.3 0 _ 18 E Exterior . Concrete Block - Int InsuIGREAT RM 5 20 0 10 0 200.0 ft' 0 0 0.3 0 _ 19 E Exterior Concrete Block - Int InsuMASTER BE 5 18 0 10 0 180.0 ft' 0 0 0.3 0 _ 20 N Exterior Concrete Block - Int InsuMASTER BE 5 26 0 10 0 260.0 ft' 0 0 0.3 0 _ 21 N Exterior Concrete Block - Int Insul .M W IC 5 10 0 10 0 100.0 ft' 0 0 0.3 0 _ 22 W Exterior Concrete Block - Int Insul M BATH 5 14 0 10 0 140.0 ft' 0 0 0.3 0 _ 23 N Exterior Concrete Block -'Int Insul M BATH 5 15 0 10 0 150.0 ft' 0 0 0.3 0 W Exterior Concrete Block - Int Insul M TOILET 5 4 0 10 0 40.0 ft' 0 0 0.3 0 _24 _ 25 S Exterior Concrete Block - Int Insul OFFICE 5 4 0 10 0 40.0 ft' 0 0 0.3 0 26 W Exterior Concrete Block - Int Insul OFFICE 5 20 0 10 0 200.0 ft' 0 0 0.3 0 DOORS i # Omt Door Type Space Storms U-Value Width Height Area Ft In . Ft 1n 1 S Insulated MUD ROOM None .23 3 6. 8 20 ft' WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 Metal Low-E Single Yes 1.05 0.25 Y 8.0 ft' 20 ft 0 in 1 ft 4 in None None 2 W 3 Metal Low-E Single Yes 1.05 0.25 Y 36.0 ft' 11 ft 4 in 1 ft4 in None None 3 W 6 Metal ' ' Low-E Single Yes 1.05 0.25 Y 36.0 ft' 7 ft 4 in 1 ft 4 in None None 4 E 10 Metal Low-E Single Yes 1.05 0.25 Y 36.0 ft' 1 ft 4 in 1 ft 4 in None None 5 E 13 Metal Low-E Single Yes 1.05 0.25 Y 24.0 ft' 20 ft 0 in 1 ft 4 in None None 6 W 14 Metal Low-E Single Yes 1.05 0.25 Y 18.7 ft' 15 ft 4 in 1 ft4 In None None 7 W 14 Metal Low-E Single Yes 1.05 0.25 Y 48.0 ft' 15 ft 4 in 1 ft 4 in None None 8 E 15 Metal Low-E Single Yes 1.05 0.25 Y 36.0 ft' 14 It 0 in 1 ft 4 in None None 9 E 18 Metal Low-E Single Yes 1.05 0.25 Y 32.0 ft' 14 ft 0 in 1 ft 4 in None None 10 N 18 Metal Low-E Single Yes 1.05 0.25 Y 48.0 ft' 14 ft 0 in 1 ft 4 in None None 11 E 19 Metal Low-E Single Yes 1.05 0.25 Y 32.0 ft' 14 ft 0 in 1 ft 4 in None None 12 E 19 Metal Low-E Single Yes 1.05 025 Y 48.0 ft' 14 ft 0 in 1 ft 4 in None None 13 N 20 Metal Low-E Single Yes 1.05 0.25. Y 32.0 ft' 11 ft 4 in 1 ft 4 in None None t 14 N 20 Metal Low-E Single Yes 1.05 0.25 Y 48.0 ft' 11 ft 4 in 1 ft4 in None None 7/9/2021 9:57 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7 F=nQnn PAn-_gngn IMPHT RUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. . / # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 _ 15 16 17 W 22 Metal Low-E Single N 23 Metal Low-E Single W 26 Metal Low-E Single Yes Yes Yes 1.05 0.25 Y 8.0 ft' 7 ft4 in 1 ft4 in , None 1.05 0.25 Y 6.7 ft' 11 ft 4 in 1 ft 4 in None 1.05 0.25 Y 36.0 ft' 11 ft 4 in 1 ft 4 in None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 950 ft' 950 ft' 23 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 2713.3 148.86 279.47 .0902 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 2 Electric Strip Heat] Electric Strip Heat] None None COPA 34 kBtulhr 1 COPA 17 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split Single SEER: 17 48 kBtu/hr 1440 cfm 0.8 1 Single SEER: 17 25 kBtu/hr 750 cfm 0.8 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Exterior '' 0.8 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM. FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS # -- Supply ---- Location R-Value Area — Return -- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # 'Heat. Cool 1 2 Attic 6 200 ft' Attic 6 130 ft' Attic Attic 20 ft' Default Leakage Attic (Default) c(Default) c 13 ft' Default Leakage Attic (Default) c(Default) c 1 1 2 2 7/9/2021 9:57 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Pnolin Jan HFeb (` sting Jan Feb Mar Mar Apr E Pr f M M Jun Jun (� Jul j Jul (� Auge [ t Aug r 1 Oct (� [ j Oct [Xj Nov Nov [ Dec [X] Dec itin Jan Feb Mar [X] A r [ May, [[[ jjj Jun E ] Jul ((j Aug Se [[[XXX]]] Oct [X) Nov [ j Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5. 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 CABANA BATH Default(8 lbs/sq.ft. ft' ft 0.3 BILLARDS Default(8 lbs/sq.ft. fN ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft' ft 0.3 " WIC 3 Default(8 Ibs/sq.ft. ft' ft 0.3 BATH 3 Default(8 Ibslsq.ft. f? ft 0.3 MUD ROOM Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft, ft' ft 0.3 BATH 2 Default(8 lbs/sq.ft. f? ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft' ft 0:3 HALL Default(8 Ibs/sq.ft, f? ft 0.3 PANTRY Default(8 Ibs/sq.ft• fe ft 0.3 LAUNDRY RM Default(8 Ibs/sq'•ft. fe ft 0.3 FOYER Default(8lbs/sq.ft. ft' ft 0.3 KITCHEN/DINING Default(8 Ibs/sq.ft. f? ft 0.3 GREAT RM Default(8 Ibs/sq.ft. ft' ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. f? ft 0.3 M W IC Default(8 Ibs/sq.ft. fN ft 0.3 M W IC 2 Default(8 Ibs/sq.ft. ft' ft 0.3 M HALL Default(8 Ibs/sq.ft. ft' ft 0.3 M BATH D'efault(8 Ibs/sq.ft. ft' ft 0.3 M TOILET Default 8 Ibs/s .ft. ft' - ft 0.3. OFFICE 7/9/2021 9:57 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7