HomeMy WebLinkAboutHEALTH DEPARMENT SEWAGE APPROVAL NCI-os-ls
STATE OF FLORIDA PERMIT #
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
EXISTING SYSTEM AND SYSTEM REPAIR EVALUATION
±ECEIVEG
4'ov'vo'ew
APPLICANT: -3 Ip U Q
CONTRACTOR/AGENT: /Ytd
Be:�ifHflg
LOT: BLOCK: SUBDIV: ID#:
TO BE COMPLETED BY FLORIDA REGISTERED ENGINEER, DEPARTMENT EMPLOYEE, SEPTIC TANK CONTRACTOR OR
OTHER CERTIFIED PERSON. SIGN AND SEAL ALL SUBMITTED DOCUMENTS. COMPLETE ALL APPLICABLE ITEMS.
COMPLETE TANK CERTIFICATION BELOW OR NOTE IN REMARKS WHY THE TANKS CANNOT BE CERTIFIED.
EXISTING TANK INFORMATION
GALLONS SEPTIC TANK/GPD ATU LEGEND: MATERIAL: � BAFFLED:(�N ]
[ ] GALLONS SEPTIC TANK/GPD ATU LEGEND: MATERIAL: BAFFLED: [Y/N ]
[ ] GALLONS GREASE INTERCEPTOR LEGEND: MATERIAL:
[ J GALLONS DOSING TANK LEGEND: t MATERIAL: # PUMPS: [ m` ]
I CERTIFY THAT THE LISTED TANKS WERE PUMPED ON \ I- /22 BY � �_ -��lC , E NE
THE VOLUMES SPECIFIED AS DETERMINED BY [ D ENSION /FILLING/LEGEND ] , ARE FRE OF OBSERVABLE
DIP OR S, AND HAVE A [ SOLIDS IaE ES IO EV (OUTLET T R DEVICE J Zl T
k
SIG URE OF LICENSED CONTRACTOR BUSINESS NAME DATE
EXISTING DRAINFIELD INFORMATION
SQUARE FEET PRIMARY DRAINFIELD SYSTEM NO. OF TRENCHES [ ] DIMENSIONS: 5' X G
[ ] SQUARE FEET SYSTEM NO. OF TRENCHES ] DIMEN IO
TYPE OF SYSTEM: STANDARD [ ] FILLED [ ] MOUND [ '] L- \ 2- 'e
CONFIGURATION: [ J TRENCH [ ] BED [ ]
DESIGN: [;� ] HEADER [ ] D-BOX (VI GRAVITY SYSTEM [ ] DOSED SYSTEM
ELEVATION OF BOTTOM OF DRAINFIELD IN RELATION TO EXISTING GRADE INCHES [ ABOVE/BELOW]
SYSTEM FAILURE AND REPAIR INFORMATION
[ ] SYSTEM INSTALLATION DATE TYPE OF WASTE [ ] DOMESTIC [ ] COMMERCIAL
[ ] GPD ESTIMATED SEWAGE FLOW BASED ON [ ] METERED WATER [ J TABLE 1, 64E-6, FAC
SITE [ ] DRAINAGE STRUCTURES [ ] POOL [ ] PATIO / DECK [ ] PARKING
CONDITIONS: [ j SLOPING PROPERTY [ ]
NATURE OF [ ] HYDRAULIC OVERLOAD [ ] SOILS [ ] MAINTENANCE [ ] SYSTEM DAMAGE
FAILURE: [ ] DRAINAGE / RUN OFF [ ] ROOTS [ ] WATER TABLE [ ]
FAILURE [ ] SEWAGE ON GROUND [ ] TANK [ ] D BOX/HEADER [ ] DRAINFIELD
SYMPTOM: [ ] PLUMBING BACKUP [ ]
�/ y�rf it
REMARKS/ADDITIONAL CRITERIA \ r�s -\ � u1 '--e \ V !- �
SUBMITTED TITLE/LICENSE DATE:`
DH 4015, 08 09 (0 soletes previous editions which may not be used)
Incorporate 64E- .001, FAC Page 4 of 4
93U' N' IVERSAL
a�o�^d5�s ENGINEERING SCIENCES
ASBESTOS CONTAINING MATERIALS
RECEIVED BUILDING SURVEY REPORT
Conducted on
4625 South Indian River Drive
Fort Pierce,St. Lucie County, Florida
St.Lucie County UES Project No. 3340.2100133.0000
perrn'Wng
Report Date:January 5, 2022
Prepared for:
Retrofits and Renovations
50 Northeast Dixie Highway, No.A7
Stuart, Florida 34994
Prepared by:
Universal Engineering Sciences
607 NW Commodity Cove
Port St. Lucie, Florida 34986
(772)924-3575
www.universalengineering.com
Geotechnical Engineering I Construction Materials Testing& Inspection
Building Code Compliance Occupational Health &Safety
Environmental Building Envelope
1
January 5,2022
Retrofits and Renovations
50 Northeast Dixie Highway, No.A7
Stuart, Florida 34997
Attn: Eden Agnew
Reference: ASBESTOS CONTAINING MATERIALS BUILDING SURVEY REPORT
4625 South Indian River Drive
Fort Pierce,St. Lucie County, Florida
UES Project No. 3340.2100133.0000
Dear Mr.Agnew:
On behalf of Retrofits and Renovations(the "client"), Universal Engineering Sciences, LLC(LIES) has
completed this National Emissions Standard for Hazardous Air Pollutants (NESHAP)Asbestos Containing
Materials Building Survey Report of one building structure located at 4625 South Indian River Drive in
Fort Pierce,St. Lucie County, Florida.This survey was conducted in accordance with Chapter 61-145 of
the United States Environmental Protection Agency's (USEPA)Title 40, Part 61,Subpart M of the Code of
Federal Regulations(CFR). This report includes the results of our findings from visual reconnaissance,field
sample collection and laboratory analysis.
This Asbestos Containing Materials Building Survey in general accordance with the scope and limitations
of NESHAP and UES's proposal dated December 10, 2021 and approved by Retrofits and Renovations on
December 14, 2021.
LIES appreciates this opportunity to provide environmental services to you and we look forward to future
endeavors. If you have any comments or questions regarding the information contained within this report or
if we can be of further service, please contact the undersigned.
Respectfully submitted,
Universal Engineering Sciences
�Ielvv-
Robert P.Crowell, P. G. Frederick G. Kaub, P.G.
AHERA Certified Asbestos Inspector Florida Licensed Asbestos Consultant
Certificate No. 08072001AM License No.AX71
i
1.0 INTRODUCTION ......................................................................................................................1
1.1 General..........................................................................................................................................1
1.2 Purpose and Scope of Work..........................................................................................................1
2.0 SURVEY METHOD....................................................................................................................1
3.0 SURVEY RESULTS.....................................................................................................................2
4.0 CONDITIONS AND LIMITATIONS OF THIS SURVEY.....................................................................3
ii
L LIST OF APPENDICES
FIGURES
SiteLocation Map.................................................................................................................Figure 1
Sample Location Sketch-15i Floor........................................................................................Figure 2A
Sample Location Sketch-Attic.............................................................................................Figure 2B
APPENDIX A
FieldLogs..........................................................................................................................................A
APPENDIX B
Laboratory Report for Asbestos Samples Collected December 23,2021........................................B
APPENDIX C
Certifications .............................................................................................................................................0
iii
Asbestos Containing .• • No.3440.2100133.0000
Building located at 4625 South Indian River Drive
Fort Pierce,St.Lucie County, • •. January 5,2022
1.0 INTRODUCTION
1.1 General
The purpose of this Asbestos Containing Materials Building Survey was to identify and assess suspect
asbestos containing materials (ACM) within one building structure located at 4625 South Indian River
Drive in Fort Pierce, St. Lucie County, Florida. UES understands that the building may be slated for
renovation/demolition.
1.2 Purpose and Scope of Work
The purpose of this study was to perform an evaluation of the above-referenced facility for the presence
of ACM, specifically those building surfaces/components which may be present or impacted during
potential renovation/demolition activities. The activities and procedures used to accomplish this task
were as follows:
1) Review available information concerning the subject building including the dates of initial
construction, significant renovations, types of construction, and information regarding the
on-site structures uses;
2) Visual building inspection of accessible areas by an inspector to identify, locate, and assess
suspect ACM;
3) Once identified,collect representative samples of suspected ACM for laboratory analysis using
polarized light microscopy;
4) Prepare and submit a report.
Complete destructive observation and sampling procedures were not generally used in UES'evaluation of
the subject building. Inaccessible areas within the building,such as crawl spaces, inside other sealed areas,
behind architectural details are beyond the scope of this study. The scope of UES' assessment did not
include an evaluation of the structure's fixtures, equipment,or stored materials.
2.0 SURVEY METHOD
On December 23, 2021, Robert Crowell, a certified Asbestos Hazard Emergency Response Act (AHERA)
Asbestos in Buildings Inspector, conducted an asbestos sampling survey of suspect asbestos-containing
building materials associated with the pending renovation/demolition of the building. A Site Location
Map is included as Figure 1. Building materials associated with the subject building proposed for
renovation/demolition were inspected and sampled as part of this survey.
During the NESHAP asbestos sampling survey conducted at the subject building,the inspector collected a
total of ten (10) bulk samples from six (6) identified homogeneous areas of suspect asbestos-containing
Page 1
Asbestos r Report Project r.3440,2100133.0000
Buildingr r at 4625 Southr Drive
Fort Pierce,St.Lucie County,Florida January 5, /
22
materials. The samples were delivered to Eurofins EMLab P&K, Fort Lauderdale, Florida, a certified
asbestos laboratory for analysis of asbestos by polarized light microscopy (PLM).
The following chart lists each homogeneous area identified and sampled during the Asbestos Containing
Materials Building Survey, the associated material class, material description, the estimated quantity of
material,the total number of samples of the material collected,the material condition, physical damage,
water damage, material contact level, and material friability:
HA ESTIMATED TOTAL (MATERIAL PHYSICAL WATER MATERIAL MATERIAL
MATERIAL MATERIAL SAMPLES
AREAS CLASS DESCRIPTION; QUANTITY CONDITION DAMAGE DAMAGE CONTACT FRIABILITY
COLLECTED
01 S Brick Mortar 200 SF 4 Good No No Low NF
02 TSI Yellow Spray-on unknown 1 Good No No Low NF
Insulation Material
03 S Brick Mortar at 50 SF 1 Good No No Low NF
Column
04 S White NC Duct Unknown 1 Good No No Low NF
Mastic
05 TSI Yellow Fibrous 500 SF 1 Good No No Low F
Insulation Material
Concrete Wall at
06 M Porch 80 SF 2 Good No No Low NF
Chart Abbreviation Notes:
HA= Homogeneous Area
M=Miscellaneous
S=Surfacing
SF=Square Feet
F=Friable
NF=Not Friable
ACT=Acoustical Ceiling Tile
VCFT—Vinyl Composite Floor Tile
Bold=Material reported to contain asbestos mineral fibers
Sketches showing the approximate sample locations for the building interior as included as Figures 2A
and 2B. Field Logs indicating the homogeneous area, sample number, description, location and NESHAP
Category of each sample collected are provided in Appendix A.
3.0 SURVEY RESULTS
The laboratory report and chain-of-custody documentation are included in Appendix B.
Asbestos mineral fibers were not detected above 1 percent in any of the building material
samples collected and tested.
UES was not informed of additional building materials that existed at the subject property prior to this
survey. If additional materials that have not been tested are discovered during renovation activities or if
any materials are found that were not accessible at the time of the survey, they should be considered
Page 2
ReportAsbestos Containing Materials Building Survey 1 1 1 1 1 1 1
Fort Pierce,St.Lucie County,Florida January 5,Building located at 4625 South Indian River Drive
Presumed Asbestos Containing Materials (PACM) in accordance with Chapter 1910.1001 of the
Occupational Safety and Health Administration's (OSHA) Title 29, Part 1910, Subpart Z of the CFR, until
laboratory testing proves otherwise. In addition,the contractor should notify the subject property owner
and UES of any such materials for further evaluation. A copy of the survey should be kept onsite during
renovation/demolition activities.
This report may not be used by the client to claim product endorsement by National Voluntary Laboratory
Accreditation Program (NVLAP) or any agency of the U.S. Government. Method used: EPA Method for
the Determination of Asbestos in Bulk Building Materials (EPA/600/R-93/116 July 1993). Copies of
relevant UES Asbestos Inspector Certifications are included as Appendix C.
4.0 CONDITIONS AND LIMITATIONS OF THIS SURVEY
A representative of UES performed the asbestos containing materials building survey on December 23,
2021. This survey is applicable for the time that the assessment was conducted. Inaccessible areas within
the building located at 4625 South Indian River Drive, such as inside partitions, under sealed, bolted metal
roof panels,inside crawl spaces,inside other sealed areas and behind architectural details are beyond the
scope of this study.
Page 3
i
lFIGURES
7-
l�`4
+, Y�
$ pYl
UNIVERSAL
ENGINEERING SCIENCES
1
u
s
s
x
UNIVERSAL
41
• .,. fir.
Jo
`N
S'N Cal
'N .. _ _
Y�Q ;
FIGURE 2A
SAMPLE LOCATION SKETCH
hu 1st Floor
4625 South Indian River Drive
Site Location
Fort Pierce, Florida UNIVERSAL
Fort Pierce FL ENGINEERING SCIENCES
10 2 3
Column Garage
Porch 5
6
4
1
9 I
Not To Scale
LEGEND
0 Asbestos Sample Location
y NORTH
.�.o.H,�. FIGURE 2B
SAMPLE LOCATION SKETCH
Attic
4625 South Indian River Drive
Florida
Site Location Fort Pierce, UNIVERSAL
FOrt PIe�Ce FL ENGINEERING SCIENCES
Stair Hatch
A/C
Handler 8
7 Q
Not To Scale
LEGEND
Q Asbestos Sample Location
M* NORTH
w-t
�4
i`
t.
�1
AM
AA
'd
UNIVERSAL
ENGINEERING SCIENCES
Date
® ASBESTOS BULK FIELD LOG
Li 6 2 S S 1 �c, �,Y, \ V� r\ve Page of
HOMOGENEOUS SAMPLE MATERIAL SAMPLE APPROXIMATE CONDITION NESHAP COMMENTS:
AREA NUMBER DESCRIPTION LOCATION QUANTITY CATEGORY
v C t i MATERIAL LOCATION:
v
0
a
Ct't Co
107 16C-C)
t,A-)1,4-c- k/c DLAz- -
�G S'�I c
yt S k l cn' �ov. a
�oG
v
NV
I�
APPENDIX B
,, �
L
mp-
UNIVERSAL
ENGINEERING SCIENCES
Oeurofins
EMLab P&K
Report for:
Mr. Rob Crowell
Universal Engineering Sciences-Port Saint Lucie
607 NW Commodity Cove
Port Saint Lucie, FL 34986
Regarding: Project: 3340.2100133.0000; 4625 Indian River Drive, Fort Pierce, FL
EML ID: 2818820
Approved by: Dates of Analysis:
Asbestos PLM: 12-30-2021
Signatory
Balu Krishnan
Service SOPs:Asbestos PLM (EPA 40CFR App E to Sub E of Part 763&EPA METHOD 600/R-93-116, SOP EM-AS-S-1267)
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report.The
results relate only to the samples as received and tested.The results include an inherent uncertainty of measurement associated
with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1%asbestos
concentration can be provided when requested.
Eurofins EMLab P&K("the Company")shall have no liability to the client or the client's customer with respect to decisions or
recommendations made,actions taken or courses of conduct implemented by either the client or the client's customer as a result
of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for
the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential
damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law,even if the Company has been
advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the
Test Results exceed the amount paid to the Company by the client therefor.
Eurofins EPK Built Environment Testing,LLC EMLab ID:2818820,Page 1 of 4
Eurofins EMLab P&K
Client: Universal Engineering Sciences-Port Saint 5750 S. Semoran Blvd.,Orlando,FL 32822
Lucie (866) 871-1984 Fax(954) 776-8485 www.emlab.com
C/O: Mr. Rob Crowell Date of Sampling: 12-23-2021
Re: 3340.2100133.0000; 4625 Indian River Drive, Date of Receipt: 12-28-2021
Fort Pierce, FL Date of Report: 01-03-2022
ASBESTOS PLM REPORT
Total Samples Submitted: 10
Total Samples Analyzed: 10
Total Samples with Layer Asbestos Content>1%: 0
Location: 01-01, Brick Mortar Lab ID-Version$:13506800-1
Sample Layers Asbestos Content
Gray Mortar ND
Sample Composite Homo enei : Good
Location: 01-02. Brick Mortar Lab ID-Version$: 13506801-1
Sample Layers Asbestos Content
Gray Mortar ND
Sample Composite Homogeneity: Good
Location: 01-03, Brick Mortar Lab ID-Version$: 13506802-1
_ Sample Layers Asbestos Content
Gray Mortar ND
Sample Composite Homogeneity: Good
Location: 01-04, Brick Mortar Lab ID-Version$: 13506803-1
Sample Layers Asbestos Content
Gray Mortar ND
Sample Composite Homogeneity: Good
The test report shall not be reproduced except in full,without written approval of the laboratory.The report must not be used by the client to
claim product certification,approval,or endorsement by any agency of the federal government.Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty(30)days,according to all state and federal guidelines,unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually.ND means no fibers were detected.when
detected,the minimum detection and reporting limit is less than 1%unless point counting is performed.Floor tile samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
I A"Version"indicated by-"x"after the Lab 1D#with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of"x".
Eurofins EPK Built Environment Testing,LLC EMLab ID:2818820,Page 2 of 4
Eurofins EMLab P&K
Client: Universal Engineering Sciences -Port Saint 5750 S. Semoran Blvd.,Orlando,FL 32822
Lucie (866) 871-1984 Fax(954) 776-8485 www.emlab.com
C/O: Mr. Rob Crowell Date of Sampling: 12-23-2021
Re: 3340.2100133.0000; 4625 Indian River Drive, Date of Receipt: 12-28-2021
Fort Pierce, FL Date of Report: 01-03-2022
ASBESTOS PLM REPORT
Location: 02-05,Yellow Spray-On Foam insulation Lab TD-Version$: 13506804-1
Sample Layers Asbestos Content
Yellow Foam ND
Sample Composite Homogeneity: Good
Location: 03-06 Brick Mortar at Column Lab ID-Version$:13506805-1
Sample Layers Asbestos Content
Gray Mortar ND
Sample Composite Homogeneity: Good
Location: 04-07, White A/C Duct Mastic Lab ID-Version$:13506906-1
Sample Layers Asbestos Content
White Mastic ND
Sample Composite Homogeneity: Good
Location: 05-08, Yellow Fibrous insulation Lab ID-Version$: 13506807-1
Sample Layers Asbestos Content
Yellow Insulation ND
Composite Non-Asbestos Content: 90%Mineral Wool
Sample Composite Homogeneity: Good
The test report shall not be reproduced except in full,without written approval of the laboratory.The report must not be used by the client to
claim product certification,approval,or endorsement by any agency of the federal government.Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty(30)days,according to all state and federal guidelines,unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually.ND means no fibers were detected.When
detected,the minimum detection and reporting limit is less than 1%unless point counting is performed.Floor tile samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
I A"Version"indicated by"x"after the Lab ID#with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of"x".
Eurofins EPK Built Environment Testing,LLC EMLab ID:2818820,Page 3 of 4
Eurofins EMLab P&K
Client: Universal Engineering Sciences -Port Saint 5750 S. Semoran Blvd., Orlando, FL 32822
Lucie (866) 871-1984 Fax(954) 776-8485 www.emiab.com
C/O: Mr. Rob Crowell Date of Sampling: 12-23-2021
Re: 3340.2100133.0000;4625 Indian River Drive, Date of Receipt: 12-28-2021
Fort Pierce, FL Date of Report: 01-03-2022
ASBESTOS PLM REPORT
Location: 06-09,Concrete Wall Lab iD-Version$: 13506808-1
Sample Layers Asbestos Content
Gray Concrete ND
Sample Composite Homogeneity: Good
Location: 06-10,Concrete Wall Lab ID-Version$:13506809-1
Sample Layers Asbestos Content
Gray Concrete ND
Sample Composite Homogeneity: Good
The test report shall not be reproduced except in full,without written approval of the laboratory.The report must not be used by the client to
claim product certification,approval,or endorsement by any agency of the federal goverment.Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty(30)days,according to all state and federal guidelines,unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually.ND means no fibers were detected.When
detected,the minimum detection and reporting limit is less than 1%unless point counting is performed.Floor tile samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$A"Version"indicated by--"x"after the Lab 1D#with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of"x".
Eurofins EPK Built Environment Testing,LLC EMLab ID:2818820,Page 4 of 4
CHAIN OF CUSTODY EM Lab P&K WNATHFR I KJ oleo '),ow wu•, i.lr•:a REQUES71ow-
III,I� �) �LIIiIL Il �I 1 �f'{'ll II
verww,EML aUPK-win rk,n-CuIturnc,i.•
002818820
•(666)871-1984 W Ter=
Cherry Hill,NJ: 1936 Olney Avenue,Cherry Hill,NJ 08003 -j H Swat S ore Biocossette
Phoenix, AZ: 1501 West Knudson Drive,Phoenix.AZ 85027 '(800)651-4802 Iran B,yt4 Water,Bulk,u...,...., ..-
San Bruno.CA: 115t)Bayhill Drive,#100, San Bruno.CA 940fii'1 ' (866)888-6653
CONTACT INFORMATION
z
Company universal Engineering Scwencos Address 607 NW Commodity Cove,Port St. Lucie, rL 34986
Spec,ml Insin,cbons _ _ _
Contact Rob Crowell &
j 8 E
Phone: Email rcrowell team fa.com
PROjECT INFORMATION LL
T11RN AROUND TIME CODES-{TAT) i ♦ ♦ I
Q !� •
STD Standard(DEFAULT) Rushes received afler 2pm or on W
Project 10 3340.2100133 0000 i1 it
ND•Next Business Day weekends,will be considered ' tt33
4625 Indian River Drive,Fort Pierce.FL received the next business day.
Project. Port St Sampling December 23,2021 SD-Same Business Day Rush Please alert us in advance of 4i
Lucie.FL ,Date& Time - weokend analysis needs.
WH Wecken<filfolida
PO Number 0
Sample Total
TAT NOTES
SAMPLE ID DESCRIPTION Type (Above) Volume Area (Time of day. Temp,RH,etc 1
(BerlowI (as appiicabte,) " a ~
X
03
02--�
ric. r
tP L c. S
.� C Cone
14171 INUUISHEU liY DATE 8 IIMF RECEIV Y DATF & Tl F
SAMPLE TYPE CODES _
NA
BC-B,oCassotte3
CP-Contact Plate T I apes D•Dust
AtS Andersen ST. Spore Trap. SW-Swab wV .Wetrn
Zefon.Allerperno
SAS surface Fur Sampler Bwki'd C
-Fulb SO•Sod
O-Other
By submitting this Chain of Custody,you agree to be bound by the lerr,s and conditions set forth At tivww emlabpk.rbmlirxms html ( 3d 2 i
Copyright*2002-2008 E MLab P&K P'4 e,, ( 0 f i 110Lm
DOC a"0116 Rw 73 Roiwwo 9n9-oa P094t t of 1.a,t
® v r
I
H
APPENDIX C
a�AN NOW
Ll
i
UNIVERSAL
ENGINEERING SCIENCES
i
Vern Roberts Environmental Training, Inc.
13987 94" Avenue N Seminole, FL 33776
727-239-1445
Certifies that
R.OE CRO ELL
Has satisfactorily completed the requisite training for asbestos accreditation under TSCA TITLE II, EPA Model
Accreditation Plan (40CFR763 E) for the 4-hour Inspector (Survey & Mechanical) Refresher Course on 8/3/2021,
and in testimony whereof, we do confer this certificate at Seminole, Florida on 8/3/2021 .
Date of Course: 8/3/2021 Expiration Date 8/3/2022
Certificate # 08032106AM
Course # FL49-0006322 Provider # FL49-0003810
/N.PT,PlIC7DR'
i
i
i
I
Ron DeSantis,Governor Halsey Beshears,Secretary
Floridar
{ STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
ASBESTOS LICENSING UNIT
THE ASBESTOS CONSULTANT HEREIN IS LICENSED UNDER THE
PROVISIONS OF CHAPTER 469, FLORIDA STATUTES
KAUB, FREDERICK GEO_RGE
GFA INTERNATIONAL INC = '
851 NE 71ST STREET
BOCA RATON FL 33487
LICENSE NUMBER: AX71
EXPIRATION DATE: NOVEMBER 30, 2022
Always verify licenses online at MyFloridaLicense.com
E A E
r.. tit
ILL- Do not alter this document in any form.
% FJ6 This is your license. It is unlawful for anyone other than the licensee to use this document.
Ron DeSantis, Governor Julie I. Brown, Secretary I
o� Florida pr
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
i
ASBESTOS LICENSING UNIT
THE ASBESTOS BUSINESS ORGANIZATION HEREIN IS LICENSED UNDER THE
PROVISIONS OF CHAPTER 469, FLORIDA STATUTES
FA INTERNATIONAL INC '
.
FREDERICK GEORGE KAUB
L.� 1215 WALLACE DRIVE ` �►►
DELRAY BEACH FL 33444
'A
LICENSE NUMBER: ZA404
EXPIRATION DATE: NOVEMBER 30, 2023
Always verify licenses online at MyFloridaLicense.com
REV.A .10
Do not alter this document in any form.
%j _
f& .. This is your license. It is unlawful for anyone other than the licensee to use this document.
0w