Loading...
HomeMy WebLinkAboutAPPROVED Revision PABCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search dbpr 4 Product Approval USER: Public User Product Approval Menu > Application Detail FL # FL2569-R23 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Sbprema, Inc. (Canada) 1640 rue Haggarty Drummondville, NON -US 00000 (819 )_478_2400 memathieu@soprema.ca Marc -Etienne Mathieu memathieu@soprema.ca Marc -Etienne Mathieu 1688 Jean-Berchmans-Michaud Drummondville, NON -US 00000 (819)478-2400 Ext3327 memathieu@soprema.ca Jean -Francois Cote, Ph.D. 1640 rue Haggarty Drummondville j888)811-3145 jfcote@soprema.ca Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Robert J. M. Nieminen PE-59166 UL LLC 12/21/2023 John W. Knezevich, PE Validation Checklist - Hardcopy Received FL2569_R23 COI OZ 21 01_COI NIEMINEN.pd Referenced Standard and Year (of Standard) Standard ASTM D1970 ASTM D4601 https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEV._sKQFEnck8108Erx1Ud3xYldTUyLi2pFprvGZEoRjE%2fHg%3d%3d Year 2015 2012 1/27122, 8:45 AM Page 1 of 3 ASTM D4798 2011 FM 4474 2011 FRSA/TRI Sixth Edition 2018 TAS 103 2020 UL1897 2015 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 07/29/2021 Date Validated 08/03/2021 Date Pending FBC Approval 08/09/2021 Date Approved 10/12/2021 Summary of Products FL # Model, Number or Name Description 2569.1 Soprema Roof Underlayments for Self adhering roof underlayments use in FBC HVHZ jurisdictions Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER Section 5 for Limits of Use. Installation Instructions FL2569_R233_Il_2021_07_29_FINAL_ER_SOPREMA_HVHZ_ �3.pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports LF 2569 R23_LE_2021_U 29_FINAL ER SOPREMA_HVHZ_FL2569 R23.pdf Created by Independent Third Party: Yes 2569.2 Soprema Roof Underlayments for Self adhering roof underlayments use in FBC non-HVHZ jurisdictions Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-150 Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The design pressure noted herein pertains to underlayment systems used beneath the roof systems. Refer to ER Section 5.8.3 for details. Installation Instructions Fd2569_R23 11_-? GZ 1_Q7__EINAL_ SOPREMA_NON- HVH _FL 2569-f?23.pdf Verified By: Robert Nieminen, P.E. PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL2569 R23 AE 2021 QZ_2FINAL_E_SOPREMA NON- HVHZ_EL25C9-R23.pdf Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copy i ht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: �0�-1 hops://www.floridabuiiding.org/pr/pr_app_dti.asox?Daram=wGEV...sKOFEnckB108Erx1Ud3xYldTUyLi2pFprvGZEoRIE%2fHg%3db3d 1/27/22, 8 A5 AM Page 2 of 3 NEMO I etc. Certificate of Authorization #32455 14 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION .®. SOPREMA, Inc. Evaluation Report 3m-SOPC-2I-FBCER.A-RI 1640 rue Haggerty FL2569-R26 (HVHZ) Drummondville, Quebec 12C 5P8 Canada Date of Issuance: 04/19/2021 (819) 478-2400 Revision 1: 07/29/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with tKe 71h Edition (2020) Florida Building Code, High Velocity Hurricane Zone sections noted herein. DESCRIPTION: SOPREMA Roof Underlayments for use in FBC HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 07/29/2021. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEW ETC, LLC ONEMOletc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: SOPREMA Roof Underlayments, as produced by SOPREMA, Inc., have demonstrated compliance with the following sections of the 7" Edition (2020) Florida Building Code, High Velocity Hurricane Zone through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Property Standard Year TAS 110 Material standard ASTM D1970 2015 TAS 110 Material standard ASTM D4601 2012 TAS 110 Material standard TAS 103 2020 TAS 110 Accelerated Weathering ASTM D4798 2011 Entity Examination Reference Date ERD (TST6049) TAS 103 (MS) S43530.02.14-1-R1 02/21/2014 ERD (TST6049) ASTM D1970 (QC) S44870.04.14-3 04/02/2014 ERD (TST6049) ASTM D1970 (OH) S44870.04.14-1 04/10/2014 ERD (TST6049) ASTM D1970 (MS) S44870.04.14-4 04/10/2014 ERD (TST6049) ASTM D1970 (OH) S40540.10.14 10/31/2014 ERD (TST6049) Tensile Adhesion / Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) ASTM D4798 SOPC-SC8520.04.14 04/27/2015 NEMO (TST6049) ASTM D1970 /TAS 110 (QC) SOPC-SC8970.08.15-R1 04/25/2018 NEMO (TST6049) Tile Slippage 4S-SOPC-18-002.09.18 09/21/2018 NEMO (TST6049) ASTM D4601 (MS) 4q-SOP-I9-SSMBB-01.A 03/11/2019 NEMO (TST6049) ASTM D4601 (OH) 4q-SOP-I9-SSMBB-01.B 03/11/2019 NEMO (TST6049) ASTM D4798/D1970 (OH & MS) 4S-SOPC-18-002.05.19.A 05/31/2019 NEMO (TST6049) Tensile Adhesion / Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020 NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020 NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-20-SSUDL-01.A 01/07/2021 NEMO (TST6049) ASTM D1970 (MS) 4j-SOPC-2I-SSUDL-01.A 04/19/2021 PRI-(TST5878) ASTM D1970 (MS) SOP-064-02-01 12/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 NEMO Traceability FBC Cross -Listing 07/28/2021 UL, LLC (QUA9625) Quality Control MLA File No. R16814 12/10/2015 UL, LLC (QUA9625) Quality Control MLA File No. R27605 05/08/2019 UL, LLC (QUA9625) Quality Control Service Confirmation 06/29/2020 UL, LLC (QUA9625) Quality Control Florida BCIS Current Product Material Standard Plant(s) Description 4.1 LASTOBOND TU HT ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric surfaced, SBS TAS 103 modified bitumen roof underlayment 4.2 SRS TopShield DEFENDER TU ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric surfaced, SBS FRSA/TRI 09-18 modified bitumen roof underlayment 4.3 Tri-Built S/A HT TU ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric surfaced, SBS Underlayment TAS 103 modified bitumen roof underlayment 4.4 Shield ASTM D1970 Drummondville, QC self adhering, woven polyethylene surfaced, SBS modified [LASTOBOND bitumen roof underlayment available in two widths; 36 and 45 inch NEMO ETC, LLC. Evaluation Report 3m-SOPC-2I-FBCER.A-R1 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL2569-R23 (HVHZ) SOPREMA Roof Underlayments Revision 1: 07/29/2021 Page 2 of 7 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 i 4.16 4.17 4.18 4.19 Product Material Standard Plant(s) Description RESISTO SA SMOOTH PLY 40 ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment LASTOBOND Shield HT ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment LASTOBOND Pro HT-N ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch LASTOBOND Pro HT-S ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment EnviroShield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment LASTOBOND Eco ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfp6rt; MS modified bitumen roof underlayment Wadsworth, OH LASTOBOND Smooth Seal HT ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, SBS Wadsworth, OH modified bitumen roof underlayment Tri-Built Smooth HT S/A ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, SBS Underlayment Wadsworth, OH modified bitumen roof underlayment PrimeSource Grip -Rite ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, SBS Smooth Seal HT Wadsworth, OH modified bitumen roof underlayment RESISTO LB1236 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfport, MS modified bitumen roof underlayment Wadsworth, OH Sand-R SA Shingle ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SB5 �TRI-BUILT erlayment Gulfport, MS modified bitumen roof underlayment Wadsworth, OH PrimeSource Grip -Rite Eave ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS & Valley Protector Gulfport, MS modified bitumen roof underlayment Wadsworth, OH SRS TopShield ICE & WATER ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS DEFENDER Gulfport, MS modified bitumen roof underlayment Wadsworth, OH RESISTO LB1244 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfport, MS modified bitumen roof underlayment Wadsworth, OH MODIFIED SOPRA-G ASTM D4601, Type II Gulfport, MS Fiberglass reinforced, SBS modified asphaltic base sheet Wadsworth, OH 5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC Non -High Velocity Hurricane Zone jurisdictions (i.e., outside of Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. NEMO ETC, LLC. Evaluation Report 3m-SOPC-2I-FBCER.A-R1 Certificate of Authorization #32455 7T" EDITION (2020) FBC HVHZ EVALUATION FL2569-R23 (HVHZ) SOPREMA Roof Underlayments Revision 1: 07/29/2021 Page 3 of 7 tONEMO Ie c. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 SOPREMA Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS FBC Section.. TAS 110(S10), TAS 110(S11), RAS 133 TAS I10(S11) RAS 130 RAS 115 RAS 118, 119 & 120 Clay and Concrete Tile Underlayment Underlayment Shingles Asphalt Metal Slate or Slate- Shingles Wood Mechanical Adhesive- Attach Set LASTOBOND TU HT, SRS TopShield Yes DEFENDER TU, Tri-Built S/A HT TU Yes Yes Yes Yes Yes Underlayment See 5.6.1 LASTOBOND Shield, Pro HT-N, RESISTO SA Yes No No Yes Yes Yes SMOOTH PLY 40 LASTOBOND Shield HT, Pro HT-S Yes No No Yes Yes Yes EnviroShield Yes No No Yes Yes Yes LASTOBOND ECO, RESISTO LB1236, TRI- BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, Yes No No No Yes Yes TopShield ICE & WATER DEFENDER, RESISTO LB1244 LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment, Grip -Rite Yes No No Yes Yes Yes Smooth Seal HT 5.6.1 Adhesive -set the is limited to use of the following underlayment / tile -adhesive combinations. TABLE 1A: ALLOWABLE UNDERLAYMENT / TILE -ADHESIVE COMBINATIONS' Underlayment Adhesive Florida Product Approval LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Underlayment Dupont "Tile Bond— Roof Tile Adhesive" FL22525 ICP Adhesives and Sealants "Polyset® AH-160" NOA 20-1124.07 'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC. Evaluation Report 3m-SOPC-2I-FBCER.A-RI Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL2569-R23 (HVHZ) SOPREMA Roof Underlayments Revision 1: 07/29/2021 Page 4 of 7 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Substrates (designed to meet wind loads for project) Underlayment Application Type Primer Material(s) LASTOBOND Shield, LASTOBOND Pro HT-N, Deck ASTM D41 structural concrete RESISTO SA SMOOTH PLY 40, LASTOBOND Dens Deck Prime or SECUROCK Shield HT, LASTOBOND Pro HT-S, Insulation (Optional) Elastocol Stick Zero Gypsum -Fiber Roof Board EnviroShield, LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Underlayment, LASTOBOND ECO, RESISTO self- LB1236, TRI-BUILT Sand-R SA Shingle adhering Underlayment, Grip -Rite Eave & Valley Base Sheet (Optional) Elastocol Stick Zero ASTM D226, Type II felt Protector, TopShield ICE & WATER DEFENDER, RESISTO LB1244, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Underlayment, Existing sand -surfaced, glass -fiber RESISTO LB1236, TRI-BUILT Sand-R SA Shingle self- Existing RESISTO EXTERIOR PRIMER surfaced, mineral -surfaced or Underlayment, Grip -Rite Eave & Valley adhering substrate film -surfaced roof underlayment* Protector or TopShield ICE & WATER DEFENDER * Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Underlayment, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support. 5.8 Attachment Limitations: Refer to Section 6 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Maximum Installation Type Exposure (days) LASTOBOND Eco, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Mechanically attached 30 Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244 LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT Mechanically attached 90 S/A Underlayment or Grip -Rite Smooth Seal HT LASTOBOND TU HT, SRS TopShield DEFENDER TU or Tri-Built S/A HT TU Underlayment Mechanically attached or 180 adhesive -set tile roof system NEMO ETC, LLC. Evaluation Report 3m-SOPC-2I-FBCER.A-R1 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL2569-R23 (HVHZ) SOPREMA Roof Underlayments Revision 1: 07/29/2021 Page 5 of 7 NNEMOI etc. 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max. 10-tile stack 6:12 Lugged Max. 10-tile stack 5:12 Double -tile stacking method, as shown below 6:12 LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Lugged ri. Underlayment �i INSTALLATION*6. 6.1 SOPREMA Roof Underlayments shall be installed in accordance with SOPREMA published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 6.3.1 Approved Assemblies: Deck Type 1: Wood, Non -Insulated Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a staggered grid -pattern between the overlaps. Cap Ply: LASTOBOND TU HT, SRS TopShield DEFENDER TU or Tri-Built S/A HT TU Underlayment, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and Table 4 for tile stagging limitations. NEMO ETC, LLC. Evaluation Report 3m-SOPC-2I-FBCER.A-Rl Certificate of Authorization #32455 7'H EDITION (2020) FBC HVHZ EVALUATION FL2569-R23 (HVHZ) SOPREMA Roof Underlayments Revision 1: 07/29/2021 Page 6 of 7 C) 6.3.2 Deck Type 1: Wood, Non -Insulated Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a staggered grid -pattern between the overlaps. Cap Ply: LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Underlayment, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT, self -adhering. Surfacing: FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate -type shingles, wood shakes or wood shingles. 6.3.3 1 Deck Type 1: Wood, Non -Insulated Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a staggered grid -pattern between the overlaps. Cap Ply: LASTOBOND ECO, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244, self -adhering. Surfacing: FBC HVHZ Approved asphalt shingles, slate, slate -type shingles, wood shakes or wood shingles. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. UL LLC—QUA9625; (414) 248-6409; Karen.buchmann(@ul.com - END OF EVALUATION REPORT - MEMO ETC, LLC. Evaluation Report 3m-SOPC-2I-FBCER.A-R1 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL2569-R23 (HVHZ) SOPREMA Roof Underlayments Revision 1: 07/29/2021 Page 7 of 7