Loading...
HomeMy WebLinkAboutLETTER-INSPECTION J�8 RECEIVED JAN 2 4 2022 PAUL WELCH INC. St.Lucie County Mechanical Electrical Civil Engineering Permittinq 1984 S.W.Biltmore St.Suite#114 Port Saint Lucie,FL 34984 Phone(772) 785-9888 January 21,2022 Re: Case#44214 Carrasco Porch Alteration 280 se Celestia Dr. Port St.Lucie,Florida To Whom It May Concern: Our office has personally inspected the Porch Alterations on 1/21/21 at the above referenced address per scope below: 1. Existing 1x non structural framing was removed 2. Framing as follows: - 44 PT posts attached with Simpson ABU44 w/(12)-16d nails'and(1)5/8"A.B.at bottom to foundation,posts wrapped w/2x framing at 16"o.c.max w/%"x 1%"embd.lags at 24"o.c.and finished w/stucco on wirelath w/11ga x 2"nails w/3/8"dia.head at 6"o.c.over tyvak bldg..wrap on 15/32"cdx plywood sheathing w/10d nails at 6"o.c. - 4x6 header attached to end post w/Simpson PC44 w/(18)-10d nails and Simpson HUSC46 w/(8)-16d nails - 2x6 rafters at 24"o.c.w/Simpson MT520 w/(14)-10d nails to 46 beam and Simpson HUS26 w/(6)-10d nails at existing rafter - 2x8 RSC fascia and stucco soffit to truss tails w/wirelath w/11ga x 2"long nails with 3/8"dia.head at 6"o.c. over 30#felt - Fiberglass shingle roof w/ 1 %" roofing nails (6) per tab on 30#felt w/tin tabs at 6" o.c. at laps and (2) staggered rows at 12"o.c.and the drip edge/valley metals w/.1%"roofing nails at 4"o.c.over 19/32"cdx plywood sheathing w/8d ringshank nails at 4"o.c.perimeters and corners and 6"o.c.in the field Our office finds that all work meets the FBC and FRC 2020,71h Edition and our engineering requirements. `:'Thank yore fo(you'r�attentign to this matter. _ f � ,,:tiAAu CHIN.• � -T` r.-d'7•''r` �., tin r Paul) e ch, E��, �• ' it.a�, y .,�.: •� �, ,;:f