HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFING BCIS Home t Log In User Registration I Hot Topics t Submit Surcharge Stats&Facts Publications Contact Usi BCIS Site Map' I Links i Search'
Florida
`' Product Approval
USER:Public User RECEIVED
FF Product Approval Menu>Product or Application Search>Application List>Application Detail q JAN 2 `� 2022 FILE t-"®Py
FL# FL33818 St.Lur iP GQUIlty
�a t Application Type New t' ff�? inn
Code Version 2020
Application Status Approved R VIEwa)
C % n ®R
Comments "r
LIANC
_- E
Archived
�� 3� 7�
Product Manufacturer Gulf Coast Supply&Manufacturing, LLC. Zv I _
Address/Phone/Email 4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352)498-0778 Ext 0565
jared.pearce@gulfcoastsupply.com
Authorized Signature Jared Pearce
jared.pearce@gulfcoastsupply.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2023
Validated By Steven M. Urich, PE
C? Validation Checklist- Hardcopy Received
Certificate of Independence FL33818 RO COI GCS20002a 2020 FBC Eval Metal Roofing NonHVHZ
final.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM B 117 2016
ASTM G 155 2013
FM 4471 1992
TAS 100 1995
TAS 110 2000
TAS 125 2003
UL1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/11/2020
Date Validated 10/31/2020
Date Pending FBC Approval 11/05/2020
Date Approved 12/16/2020
Summa of Products
FL# Model, Number or Name Description
33818.1 Metal Roofing Systems (HVHZ) GulfLok,VersaLoc, 5V Crimp, GulfPBR and GUIfRib
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL33818 RO II GCS20002b 2020 FBC Eval Metal Roofing.
Approved for use outside HVHZ: No HVHZ final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: +0/-164.25 Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL33818 RO AE GCS20002b 2020 FBC Eva[ Metal Roofing.
HVHZ final.pdf
Created by Independent Third Party: Yes
3818.2 Metal Roofing Systems (nonHVHZ) Gulfl-ok, GulfSeam, Megal-oc,VersaLoc, Crimp, lfPBR,
GulfRib and GulfWave
se Installation Instru 11 ctions
Approved for use in HVHZ: No FL33818 RO II GCS20002a 2020 FBC Eva] Metal Roofing,
Approved for use outside HVHZ:Yes NonHVHZ final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: +0/-164.25 Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL33818 RO AE GCS20002a 2020 FBC Eval Metal Roofing,
NonHVHZ final.pdf
Created by Independent Third Party: Yes
Hnck Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
W-711 ® er;heck
ffW
Credit Card
Safe
Certificate of Authorization No. 29824
R E E K17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,7T"EDITION(2020)
Manufacturer: GULF COAST SUPPLY& MANUFACTURING, LLC Issued October 22, 2020
14429 SW 2"d Place,Suite G30
Newberry, FL 32669
(352)498-7852
www.gulfcoastsupp[V.com
Manufacturing Locations: Alachua, FL
Sebring, FL
Montgomery,AL
Quality Assurance: Keystone Certifications, Inc. (QUA1824)
SCOPE
Category: Roofing
Subcategory: Metal Roofing
Code Sections: 1504.3
Properties: Wind Resistance
REFERENCES
Entity Report No. Standard Year
Force Engineering&Testing(TST5328) 72-0313T-06A-C UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 72-0198T-07A-C UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0033T-05 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0053T-05 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0062T-07A-C UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0062T-07D-F UL 580 2006
UL1897 2012
Force Engineering&Testing(TST5328) 117-0062T-07G-1 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0062T-07J-K UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0065T-07A-C UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0076T-12A UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0089T-05.1 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0089T-05.2 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0102T-05 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0165T-11 B UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0238T-09D FM 4471 1992
Force Engineering&Testing(TST5328) 117-0238T-09E FM 4471 1992
Force Engineering&Testing(TST5328) 117-0238T-11A FM 4471 1992
Force Engineering&Testing(TST5328) 117-0248T-07A,B UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0284T-09A UL 580 2006
UL 1897 2012
GCS20002a FL33818 Page 1 of 6
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEKGULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES, LLC
Entit Report _
� q rt No. Standard Year
Force Engineerin &Testin TST5328 117-0285T-09A U 9 9( ) L 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0301T-10A-C UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0330T-10A-B UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0331T-08A UL 580 2006
UL 1897 - 2012
Force Engineering&Testing(TST5328) 117-0331T-08B UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0331T-08D UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0337T-10 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 11 7-0378T-1 1A FM 4471 1992
Force Engineering&Testing(TST5328) 117-0378T-116 FM 4471 1992
Force Engineering&Testing(TST5328) 117-0378T-11 C FM 4471 1992
Force Engineering&Testing(TST5328) 117-0407T-09 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 117-0407T-09A UL 580 2006
UL.1897 2012
Intertek-West Palm Beach(an ATI company) (TST1527) B9000.01-450-18 UL 580 2006
UL 1897 2012
Intertek-West Palm Beach(an ATI company) (TST1527) C0308.01-450-18 UL 580 2006
UL 1897 2012
Intertek-West Palm Beach(an ATI company) (TST1527) D0818.01-450-18 UL 580 2006
Intertek-West Palm Beach(an ATI company) (TST1527) D1692.01-450-44 UL 580 2006
UL 1897 2012
ASTM E 8
Intertek-West Palm Beach(an ATI company) (TST1527) G7287.01-450-44 UL 580 2006
PRI Construction Materials Technologies(TST5878) 1272T0005 ASTM G 155 2013
1
GCS20002a FL33818 Page 2 of 6
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
" CREEK GULF COAST SUPPLY_ &MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
GulfLok ( Profile: _ ! 1 in.snap lock seam;Max.16 in.coverage
�Descri tion: Non-structural,snap lock standing seam roof panel with 7/8 in.slotted nail strip
Material: Min.26 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint
k finish; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3
Min.0.032 in.ASTM B209,3105 H24 aluminum; Optional Fluropon®paint finish;
Fy=min.24"ksi; Shall conform with"FBC Section 1507.4.3
._.___.._._._.......... -_...._................__......... —- .................. --._..._..._._........................_-.__.........._......_...__............_.......__._......
_-...-
I
1n
12"'an0116 I overage
GulfSeam Profile: 1 3/4 in.snap lock seam; Max. 18 in. coverage
I Description: ( Non-structural,snap lock standing seam roof panel
Material: Min.24 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint
{ finish; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 _
Min.0.032-inch ASTM B209,3105 H24 aluminum, Optional Fluropon®.paint finish;
Fy=min.21 ksi; Shall conform with FBC Section 1507.4.3
3ra�
441"AV%;and 18".Coveragel.
MegaLoc Profile: ( 2 in.mechanical seam; Max. 18 in.coverage_
_..._._..._._ —_......................---... _ _...._....................._
Description: E Non-structural,mechanical,lock 180°standing seam roof panel
Material: Min.24 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint
( finish; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3
I
I z^
16'-18'Covcrage
GCS20002a FL33818 Page 3 of 6
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
GDEEK GULF COAST SUPPLY&MANUFACTURING,LLC
it Metal Roofing
TECHNICAL SERVICES, LLC
VersaLoc i Profile:- - 1.5 in. mechanical seam; Max. 18 in.coverage -- - ---
—'—
Description Non-structural, mechanical lock 1800 standing seam roof panel
Material: Min.24 ga:ASTM A792 AZ50 or ASTM A653 G90;Optional Fluropon®paint
finish; F =min 50 ksi; Shall conform with FBC Section 1507.4.3
i __..._.._..........._..-�--- __Y._._.—__... .._._......._._.. --......._ ._...............---.-.--'--.:._...................
i
I
f
i
i
i
1!2
16".-l8"CoveragQ;
5V Crimp rofile: 7/16 in. ribs at 12 in.o.c.;24 in.coverage
i escri tion: Non structural,through fastened roof panel
Material: Min.26 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®,paint
finish; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 _
Min. 0.032 in.ASTM B209, 3105 H?4 aluminum;Optional Fluropon®paint finish;
i I Fy=min.25 ksi; Shall conform with FBC Section 1507.4.3
i
i
I
i
+
i
71,16"# 12"
- - � 24"Coverage-.
GulfPBR Profile: 1 1/4 in.ribs at 12 in.o.c.;36 in.coverage
Description: Non-structural,through fastened roof panel
......................-__-—'----__....y... — __._.........__.-'--'--'---..._................----"-'---.__...-__......._........._..-____...--'---__..............
Material: ( Min.26 ga.ASTM A792 AZ50 or ASTM A653 G90;Optional Fluropon®paint
j finish; F min.80 ksi; Shall conform with FBC Section 1507.4.3
_......................__ .............
__._.........__..._..-.. ---_ --- _
i
I
i
�Z!'
Coverage=
i ..
GCS20002a FL33818 Page 4 of 6
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEKGULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES, LLC
GulfRib j Profile: 3/4 in. ribs at 9 in.o.c._36 in.coverage
_..__ _
Description: i Non-structural,through fastened roof panel
Material: Min.29 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint
finish; Fy=min.80 ksi; Shall conform with FBC Section 1507.4.3
9 .
n
36"'Coverage.
GulfWave Profile: 3/4 in.corrugation;29 in.coverage
— _..-. - - ---. _..... ---
Description: Non-structural,through fastened roof panel
_....._........-- --- -- --
-------
Material: Min.26 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint
- finish; Fv=min.80 ksi; Shall conform with FBC Section 1507.4.3
I
"DWI
3/4"
Z.g"..Cove'rage;
GCS20002a FL33818 Page 5 of 6
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GULF COAST SUPPLY&MANUFACTURING,LLC
CREEKMetal Roofing
TECHNICAL SERVICES, LLC
LIMITATIONS
1. Fire classification is not within the scope of this evaluation.
2. This report is not for use in the HVHZ.
3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
4. Roof slope shall be in accordance with FBC Section 1507.4.2.
5. Reroofing shall be in accordance with FBC Section 1511. Recovery versus replacement shall be evaluated
in accordance with FBC Section 1511.3.
6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
7. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code,7`h Edition(2020)as evidenced in the referenced documents submitted by the named manufacturer.
%`QG,�PaG E N3 /�S,ii .,_.,: 2020. 10.22
* • ••.* 15:51 :16
' No 74021
_ * e� .r '<�dWH4pnaEgLrleryRPrleet <+`�.• :. •.ei• 4
a�•• STATE OF '�/
����F•'• O R 1'D.• 0���`� Zachary R. Priest, P.E.
i��sSIONA;Sim��', Organa ation No.Floridl on ANE9641 21
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
APPENDICES
1) APPENDIX A—Installation (5 pages)
2) APPENDIX B—Approved Roof Systems(7 pages)
3) APPENDIX C—Design Wind Loads (4 pages)
GCS20002a FL33818 Page 6 of 6
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GULF COAST SUPPLY&MANUFACTURING,LLC
CREEKMetal Roofing
TECHNICAL SERVICES, LLC
APPENDIX A
INSTALLATION
Note-Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system.
Unless otherwise specified in this report the following installation details shall be met for the named products:
Component Product Installation Detail
#9-15 HWH wood screw
with sealing washer
#9-15 HWH WoodZAC
screw
#10-12 Pancake Type A Shall penetrate through the sheathing a minimum 3/8 in. Shall be corrosion
screw resistant in accordance with FBC section 1507.4.4.
Fasteners #12-11 Pancake Type A
screw
#12-8 HWH Woodgrip
XG screw with sealing
washer
1/4-14 HWH ZAC Impax Installed at panel side lap;Shall be corrosion resistant in accordance with FBC
Lap screw section 1507.4.4.
24 ga.in-seam clip
11 r
I k _T
GulfLok Clip
c*i
Clips
18 ga.in-seam clip
T I�
Fixed Clip
\>/
-2.11 `
GCS20002a FL33818
Page I o f5
`This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
' CREEKGULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL"SERVICES, LLC
APPENDIX A
Component Product Installation Detail
0.78
- - - - - - - - - - - -
2"
NC-33003-3 Sliding Clip
7�_� 2
1/2"
Clips(Cont'd) -
22 ga.top; 16 ga.base;in-seam clip
(109.22)
4.30 (9.65) (6.86)
1
0.38 0.27
1
1500SC Sliding Clip _T j
(51,31) (38.61)
❑ ir3 _a 2.02 1.52
to 16,
0.40 1
Sealants TiteBond Weathermaster Shall be applied in 1/4%5/16"continuous beads on the male rib along the seam
Metal Roof Sealant
Fastening Details
Nomenclature Attachment
GulfLok Type 1
(1) #10-12 X 1"TYPE A PANCAKE
1.18" 43 STAINLESS
GULF LOK PANEL STEEL RIVET @ 6"
(OVERLAP StDEy O C
GulfLok Overlap
GULF L01C PANEL
�"Ul�`DERLAP SIDE)
PANCLIP SCREL"",t
GCS20002a FL33818 Page 2 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
Ii
i
CREEKGULF COAST SUPPLY&MANUFACTURING,LLC
R Metal Roofing
TECHNICAL SERVICES, LLC APPENDIX A
Fastening Details
Nomenclature Attachment
GulfLok'" CLIP 24 GA.
GulfLok Type 2
(1) #10-12 X 1"TYPE A PANCAKE
18 Ga. Fixed Clip MT
GulfSeam Type 1
(2) #10-12 x 2"Pancake Type A Per Clip.
CV
MegaLoc Type 1
C-33003 SLIDING CLIP
(2) #10-12 x 1"per Clip—/
*=1N
T
VersaLoc Type 1 -�
T-1500SC SLIDING CLIP `
(2)#12-11 x 1"Panhead per Clip
(1) #9-15 x 1-1/2" HWH w/Sealing Washer
5V Type 1
12" 12" �
At Panel Lap
(1) #9-15 x 1 -1/2" HWH w/Sealing Washer
5V Type 2 � 2" � 9.511
.5'I joillit 9.511
.5" �211
GCS20002a FL33818 Page 3 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GULF COAST SUPPLY&MANUFACTURING,LLC
CREEKx Metal Roofing
TECHNICAL SERVICES, LLC APPENDIX A
Fastening Details
Nomenclature Attachment
A1211A 1211 �
5V Type 3
At Panel Lap
(1) #9-15 x 1-1/2" HWH w/Sealing Washer
At Panel Lap
#1/4-14 x 7/8"Lap Screw @ 24"O.C. Max.
1211 1211 1211
GulfPBR Type 1
(1) #9-15 x 1-1/2"
#1/4-14 x 7/8"Lap Screw @ 24"O.C.Max.
511 711 511 �711 511 711 511
GuIiPBR Type 2 � � �I �
l
(1)#9-15 x 1-1/2"
At Panel Lap
GulfRib Type 1
�(1)#9-15 x 1-1/2°w/Sealer Washer
6.5" 2.511-{-6.5" 2.5"-{—6.5"�2.5"-{-6.5"�2.5"
GulfRib Type 2 /I I i
�(1)#9-15 x 1-1/2"w/Sealer Washer
GCS20002a FL33818 Page 4 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
GULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
\ TECHNICAL SERVICES, LLC
APPENDIX A
Fastening Details
Nomenclature Attachment
GulfRib Type 3
#�15. w Sealer Washer
At Panel Lap
919 911 911 7�F 6.5"-72.5"
GulfRib Type 4
zo)#12-8 x 1-1/2"WoodGrip XG W/Sealer Washer
At Panel Lap
�811�811�811�5.3311�
GulfWave Type 1
1) #9-15 x 1-1/2" HWH w/Sealin9 Washer
GCS20002a FL33818 Page 5 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES,LLC APPENDIX B
APPROVED ROOF SYSTEMS
The following notes shall be observed when using the assembly tables below.
1. Maximum Design Pressure(MDP)was calculated using a 2:1 margin of safety per FBC Section 1504.9.
2. Refer to LIMITATIONS and sections of this evaluation when using the table(s)below.
3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly.
4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the rated system.
5. The panel thickness or gauge is the minimum allowable.
6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga (Fy=min.40 ksi)Wide Rib Deck(Type WR)
conforming to ANSI/SDI-RD1.0&FBC.
7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32-inch thick APA Span-Rated plywood
sheathing at maximum 24-inch span.
Roof System Numbers and Definitions
LOK-W# GulfLok over Wood Deck New or Existing)
SEAM-W# GulfSeam over Wood Deck(New or Existing)
MEGA-W# Me aLoc over Wood Deck New or Existing)
VL-W# 1.5"VersaLoc over Wood Deck new or Existing)
5V-W# 5V Crimp over Wood Deck New or Existing)
PBR-W# GulfPBR over Wood Deck New or Existing)
RIB-W# GulfRib over Wood Deck New or Existing
WAVE-W# GulfWave over Wood Deck New or Existing)
Approved Systems for GulfLok over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No.
(psf)
Min. 15/32 OPTIONAL 26 ga.,Grade 80 GulfLok GulfLok Type 1 attachment #10-12 x 1"
LOK-W-1 B-C plywood Approved fire barrier As required per FBC Max. 16-inch coverage Pancake Type A p screws spaced 5-3/16 in.o.c -63.5
or insulation
Min. 15/32 OPTIONAL Min.0.032"All GulfLok GulfLok Type 1 attachment with #10-12 x 1"
LOK-W-2 B-C plywood Approved or insulation fire barrier As required per FBC Max. 16-inch coverage Pancake Type A screws spaced 5-3/16 in.o.c. -65.5
Min. 15/32 OPTIONAL 24 ga.GulfLok GulfLok Type 1 attachment with#10-12 x 1"
LOK-W-3 B-C plywood Approved fire barrier As required per FBC Max. 16-inch coverage Pancake Type A screws spaced 10-1/4 in.o.c. -81.75
or insulation
Min. 15/32 OPTIONAL 24 ga.GUIfLok GulfLok Type 1 attachment with#10-12 x 1"
LOK-W 4 B-C plywood Approved fire barrier As required per FBC Max. 16-inch coverage Pancake Type A screws spaced 5-1/8 in.o.c. 96.75
or insulation
GCS20002a FL33818 Page 1 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
CREEK
�Lo." GULF COAST SUPPLY&MANUFACTURING,LLC
�- jam.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for GulfLok over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
OPTIONAL GulfLok Type 1 attachment with #10-12 x 1"
Min.15/32 Min.0.032"AI Gulfl-ok Pancake Type A screws spaced 5-3/16 in.o.c.
LOK-W-5 B_C plywood Approved fire barrier As required per FBC or insulation Max. 16-inch coverage Titebond Weathermaster Metal Roof Sealant -116
applied to male rib.
OPTIONAL GulfLok Type 1 attachment with#10-12 x 1"
Min. 15/32 Min.26 ga.Gulfl-ok Pancake Type A screws spaced 5-3/16 in.o.c.
LOK-W-6 CDX plywood Approved fire barrier As required per FBC or insulation Max. 16-inch coverage Titebond Weathermaster Metal Roof Sealant -121.75
applied to male rib.
Min. 15/32 OPTIONAL 26 ga.,Grade 80 Gulfl-ok GulfLok Type 2 attachment with
LOK-W-7 B_C plywood Approved fire barrier As required per FBC Max.16-inch coverage #10-12 x 1"Pancake Type A screws through -161
or insulation clip and spaced 5-3/16 in.o.c.
Approved Systems for GulfSeam over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min.15/32 OPTIONAL Min.24 ga.GulfSeam GulfSeam Type 1 attachment
SEAM-W-1 g_C plywood Approved fire barrier As required per FBC or insulation Max.18-inch coverage with clips spaced 24 in.o.c. 69.25
Min. 15/32 OPTIONAL Min.0.032"AI GulfSeam GulfSeam Type 1 attachment
SEAM-W-3 COX plywood Approved fire barrier As required per FBC Max. 18-inch coverage with stainless steel clips spaced 18 in.o.c. -86
or insulation
Min. 1x4 No.2
SYP wood
purlins spaced OPTIONAL Min.24 ga.GulfSeam GulfSeam Type 1 attachment with clips spaced
SEAM-W-4 18 in.o.c. Approved fire barrier As required per FBC Max.16-inch coverage 18 in.o.c.over wood purlins -93.5
over or insulation
Min. 15/32
B-C plywood
Min. 15/32 OPTIONAL Min.24 ga.GulfSeam GulfSeam Type 1 attachment
SEAM-W-5 B_C plywood Approved or insulation fire barrier As required per FBC Max. 18-inch coverage with clips spaced 12 in.o.c. -108.5
GCS20002a FL33818 Page 2 of 7
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEKGULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES, LLC APPENDIX B
Approved Systems for GulfSeam over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min.1x4 No.2
SYP wood
purlins spaced OPTIONAL Min.24 ga.GulfSeam GulfSeam Type 1 attachment with clips spaced
SEAM-W-6 24 in.o.c. Approved fire barrier As required per FBC Max. 18-inch coverage 24 in.o.c.over wood purlins -114.25
over or insulation
Min.15/32
CDX plywood
Min. 15/32 OPTIONAL Min.0.032"Al GulfSeam GulfSeam Type 1 attachment
SEAM-W-7 CDX plywood Approved fire barrier As required per FBC Max. 16-inch coverage with stainless steel clips spaced 6 in.o.c. -138.5
or insulation
Min. 1x4 No.2
SYP wood
purlins spaced OPTIONAL Min.24 ga.GulfSeam GulfSeam Type 1 attachment with clips spaced
SEAM-W-8 12 in.o.c. Approved fire barrier As required per FBC Max. 18-inch coverage 12 in.o.c.over wood purlins -159.25
over or insulation
Min. 15/32
CDX plywood
Approved Systems for MegaLoc over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min. 15/32 OPTIONAL Min.24 ga.MegaLoc MegaLocType 1 attachment
MEGA-W-1 g_C plywood Approved or insulation fire barrier As required per FBC Max. 18-inch coverage with clips spaced 24 in.o.c. -71
Min.15/32 OPTIONAL Min.24 ga.MegaLoc MegaLocType 1 attachment
MEGA-W-2 B-C plywood Approved or insulation fire barrier As required per FBC Max.18 inch coverage with clips spaced 12 in.o.c. -108.5
GCS20002a FL33818 Page 3 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
"Approved Systems for VersaLoc over Wood Deck(New or Existing)
System DP
Deck ,Fire Barrier ��- Underlayment" R- of Panel . � � Panel Attachment M
No o0
P,
Min. 15/32 - OPTIONAL Min.24 ga.VersaLoc VersaLoc Type 1 attachment
VL-W-1 B-C plywood Approved fire barrier As required per FBC, Max. 16-inch coverage with clips'spaced 24 in.o.c. -59.75
or insulation
Min. 15/32 OPTIONAL Min.24 ga.VersaLoc VersaLoc Type 1 attachment
VL-W-2 B-C plywood Approved or insulation fire barrier As required per FBC Max.16-inch coverage with clips spaced 6 in.o.c. -123.5
Approved Systems for 5V Crimp over Wood Deck(New or Existing)
System -Fire-Barrier/ 'MDP�,
Deck _ Underlayment Roof Panel Panel Attachment
No. =Insulation (psi _
OPTIONAL
Min.15/32 Min.26 ga.5V Crimp 5V Crimp Type 3 attachment with#9-15 HWH wood
5V-W1 B-C plywood
or insulation Approved fire barrier As required per FBC 24-inch coverage screws with sealing washers spaced 16 in.o.c. -94.25
OPTIONAL. Min.0.032"Al or
5V-W2 Min.plywood
Approved fire barrier As required per FBC . Min.26 ga.5V Crimp 5V Crimp Type 1 attachment with aced#9-1 HWH wood -108.5
B-C plywood or insulation 24-inch coverage screws with sealing washers spaced 12 in.o.c:
- 5V-W3
Min.15/32 OPTIONAL n.26 ga.5 attachment with#9-15 HWH wood
Min. Crimp 5V Crimp Type 2 att g_C plywood Approved or insulation fire barrier As required per FBC 24-inch coverage screws with sealing washers spaced 16 in.o.c. -131 "
Min.15/32 OPTIONAL Min.26 ga.5V Crimp 5V Crimp Type 1 attachment with
5V-W4 B-C plywood Approved fire barrier As required per FBC 24-inch coverage #9-15 HWH wood screws with sealing washers spaced 6 -156.5
or insulation in.o.c.
GCS20002a FL33818 Page 4 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other
product attributes that are not specifically addressed herein.
I
` CREEK GULF COAST SUPPLY&MANUFACTURING,LLC
TECHNICAL SERVICES, LLC Metal Roofing
APPENDIX B
Approved Systems for GulfPBR over Wood Deck(New or Existing)
System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP
No. Insulation (psf)
OPTIONAL GulfPBR Type 1 attachment with#9-15 15 HWH WoodZAC
Min.15/32 Min.26 ga.GuIfPBR screws spaced 24 in.o.c.
PBR-W-1 B-C plywood Approved fire barrier As required per FBC or insulation 36-inch coverage Laps fastened with 1/4-14 x 7/8"HWH ZAC Impax Lap -60.5
screws spaced 24 in.o.c.
Min.1x4 No.2
SYP wood GulfPBR Type 1 attachment with 99-15 HWH WoodZAC
purlins spaced OPTIONAL Min.26 ga.GUIfPBR screws spaced 24 in.o.c.into wood purlins
PBR-W-2 24 i Approved fire barrier As required per FBC 36-inch coverage Laps fastened with 1/4-14 x 7/8 ZAC Impax Lap screws -100.5
ovverr or insulation
Min.15/32 spaced 24 in.o.c.
B-C plywood
Min.1x4 No.2
SYP wood
purlins spaced OPTIONAL GulfPBR Type 2 attachment with#9-15 15 HWH
PBR-W-3 12 in.o.c. Approved fire barrier As required per FBC Min.26 ga.GulfPBR WoodZAC screws spaced 12 in.o.c.into wood purlins -151.75
over or insulation 36-inch coverage Laps fastened with 1/4-14 x 7/8"HWH ZAC Impax Lap
Min.15/32 screws spaced 24 in.o.c.
B-C plywood
OPTIONAL GulfPBR Type 2 attachment with#9-15 HWH WoodZAC
Min.15/32 Min.26 ga.GulfPBR screws spaced 12 in.o.c.
PBR-W 4 B-C plywood Approved fire barrier As required per FBC or insulation 36-inch coverage Laps fastened with 1/4-14 x 7/8"HWH ZAC Impax Lap -154.75
screws spaced 24 in.o.c.
Approved Systems for GulfRib over Wood Deck(New or Existing)
System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP
No. Insulation (psf)
OPTIONAL Min.29 ga.GulfRib GulfRib Type 4 attachment with#12-8 HWH Woodgrip XG
RIB-W-1 Min.7/16 OSB Approved fire barrier As required per FBC 36-inch coverage wood screws with sealing washers spaced 24 in.o.c. -22.66
or insulation
Min. 15/32 OPTIONAL Min.29 ga.GulfRib GulfRib Type 3 attachment with#9-15 HWH wood screws
RIB-W-2 CDX plywood Approved fire barrier As required per FBC 36-inch coverage with sealing washers spaced 24 in.o.c. -56
or insulation
GCS20002a FL33818 Page 5 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for GulfRib over Wood Deck(New or Existing)
System Fire Barrier/ MDP
Deck UnderlaY ment Roof Panel Panel Attachment "
No.. Insulation (Psfl-.
Min.15/32 OPTIONAL Min.29 ga.GulfRib GulfRib Type 9 attachment with#with#9-15 HWH
RIB-W-3 B-C plywood Approved fire barrier As required per FBC 36-inch coverage. WoodZAC screws spaced 24 in.o.c -71.75
or insulation
Min.1x4 No,
2
SYP wood
purlins spaced OPTIONAL GulfRib Type 1 attachment with#9-15 x•1 1/2"HWH wood
RIB-W-4 24 in.o.c. Approved fire barrier As required per FBC Min.nc ga. BragGulfRib screws with sealing washers spaced 24 in.o.c. -76.75
over or insulation 36-inch coverage into wood purlins
Min.'15/32
B-C plywood
Min.1x4 No.2
SYP wood OPTIONAL GulfRib Type 1 attachment with x 1 1/2"HWH wood
RIB-W-5 purlins spaced Approved fire barrier As required per FBC Min.29 ga.GulfRib screws with sealing washers spaced 24 in.o.c. -101
24 in.o.c. or insulation 36-inch coverage into wood purlins
over
Min.7/16 OSB
OPTIONAL
Min.15/32 Min.29 ga.GulfRib GulfRib Type 3 attachment with#9-15 HWH wood screws
RIB-W-6 CDX plywood. Approved fire barrier As required per FBC 36-inch coverage with sealing washers spaced 12 in.o.c. -101
or insulation
Min.1x4 No.2
SYP wood
purlin's spaced OPTIONAL Min.26 ga.GulfRib GulfRib Type 1 attachment with#9-15 HWH WoodZAC
RIB-W-7 24 i Approved fire barrier As required per FBC 36-inch coverage screws spaced 24 in.o.c.into wood purlins 106.75
ovverr or insulation
Min.15/32
B-C plywood
OPTIONAL Min.29 ga.GulfRib GulfRib Type 4 attachment with#12-8 HWH Woodgrip XG
RIB-W-8 Min.7/16 OSB Approved fire barrier As required per FBC -116.0
or insulation 36-inch coverage wood screws with sealing washers spaced 6 in.o.c.
GCS20002a FL33818 Page 6 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
{ CREEKGULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for GulfRib over Wood Deck(New or Existing)
System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP
No. Insulation (psf)
Min. 1x4 No.2
SYP wood
purlins spaced OPTIONAL GUIfR%b Type 2 attachment with#9-15 x 1 1/2"HWH wood
RIB-W-9 24 in.o.c. Approved fire barrier As required per FBC Min.36-i nc ga.h coverage
GulfRib screws with sealing washers spaced 24 in.o.c. -123.5
over or insulation e into wood purlins
Min.15/32
B-C plywood
Min.15/32 OPTIONAL Min.29 ga.GulfRib GulfRib Type 2 attachment with#9-15 HWH wood screws
RIB-W-10 B-C plywood Approved fire barrier As required per FBC 36-inch coverage with sealing washers spaced 12 in.o.c. -146.0
or insulation
Min. 15/32 OPTIONAL Min.26 ga.GulfRib GulfRib Type 2 attachment with#9-15 HWH WoodZAC
RIB-W-11 B-C plywood Approved fire barrier As required per FBC 36-inch coverage screws spaced 12 in.o.c. -159.25
or insulation
Min.1x4 No.2
SYP wood
purlins spaced OPTIONAL Min.26 ga.GulfRib GulfRib Type 1 attachment with#9-15 HWH WoodZAC
RIB-W-12 12 in.o.c. Approved fire barrier As required per FBC 36-inch coverage screws spaced 12 in.o.c.into wood purlins -164.25
over or insulation
Min.15/32
B-C plywood
Approved Systems for GulfWave over Wood Deck(New or Existing)
System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP
No. Insulation (psf)
Min. 15/32 OPTIONAL Min.26 ga.GulfWave GulfWave Type 1 attachment with
WAVE-W1 B-C plywood Approved fire As required per FBC 29-inch coverage #9-15 HWH wood screws with sealing washers -78.5
barrier or insulation spaced 24 in.o.c.
GCS20002a FL33818 Page 7 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
CREEK GULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX C
DESIGN WIND LOADS
The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-16 under the following
provisions:
1. Wind speeds for risk category I, Il, III,and IV buildings shall be as defined in Section 1609 of the FBC.
2. Exposure B,C,and D shall be as defined in section 1609 of the FBC.
3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12
4. All calculations are based on an effective wind area of 10-ft2 or less.
5. Topographic factors such as escarpments or hills have been excluded from the analysis
6. Overhangs have been excluded from the analysis.
7. Wind directionality factor, Kd=0.85
8. Vuit is shown in the tables below. Design wind loads are calculated using Vasd=Vult110.6 per 1609.3.1.
9. Zone 2 is inclusive of Zone 2e,Zone 2n,and Zone 2r
10. Zone 3 is inclusive of Zone 3e and Zone 3r
11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional
12. Zones 1, 2,and 3 shall be defined as shown below. Dimension"a"shall be 10%of the least horizontal dimension or(0.4 x Mean Roof Height),whichever
is smaller, but not less than either 4%of the least horizontal dimension or 3ft
Gable Hip
_ X
3 2 3 3 2 3 a \ [X2
3 a
2 1 2 2 1 2 2
_3 2 3 3 2 3 a 3 a
lal laIal lal lal lal
GCS20002a FL33818 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
:2 CREEKGULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX C
Gable/Hip Roofs in Exposure B Roof slope between 2:12 and 12:12
Mean Basic Wind Speed I mph)
Building Type Zone - Roof - 120 .130 140 150 160 170 180 ' 190` 200
Height ft
20 -25.4 -29.8 -34.6 -39.7 -45.2 -51.0 -57.2 -63.7 -70.6
25 -27.5 -32.2 -37.4 -42.9 -48.8 -55.1 -61.8 -68.8 -76.3
1 30 -28.7 -33.7 -39.1 44.8 -51.0 -57.6 -64.6 -71.9 -79.7
40 -31.2 -36.6 -42.4 -48.7 -55.4 -62.5 -70.1 -78.1 -86.5
50 -33.2 -39.0 -45.2 -51.9 -59.0 -66.6 -74.7 -83.2 -92.2
60 -34.8 -40.9 -47.4 -54.4 -61.9 -69.9 -78.4 -87.3 -96.8
20 -37.1 -43.5 -50.5 -57.9 -65.9 -74.4 -83.4 -92.9 -103.0
25 -40.1 -47.0 -54.5 -62.6 -71.2 -80.4 -90.1 -100.4 -111.3
Enclosed/ 2 30 -41.9 -49.1 -57.0 -65.4 -74.4 -84.0 -94.2 -104.9 -116.3
Partially Open 40 -45.4 -53.3 -61.9 -71.0 -80.8 -91.2 -102.2 -113.9 -126.2
50 -48.4 -56.8 -65.9 -75.7 -86.1 -97.2 -109.0 -121.4 -134.5
60 -30.0 -35.3 -40.9 -46.9 -53.4 -60.3 -67.6 -75.3 -83.5
20 -44.1 -51.7 -60.0 -68.8 -78.3 -88.4 -99.1 -110.5 -122.4
25 -47.6 -55.9 -64.8 -74.4 -84.7 -95.6 -107.1 -119.4 -132.3
3 30 49.8 -58.4 -67.7 -77.7 -88.4 -99.8 -111.9 -124.7 -138.2
40 -54.0 -63.4 -73.5 -84.4 -96.0 -108.4 -121.5 -135.4 -150.0
50 -57.6 -67.6 -78.4 -90.0 -102.3 -115.5 -129.5 -144.3 -159.9
60 -60.4 -70.9 -82.2 -94.4 -107.4 -121.2 -135.9 -151.4 -167.8
20 -29.7 -34.9 -40.5 46.5 -52.8 -59.7 -66.9 -74.5 -82.6
25 -32.1 -37.7 -43.7 -50.2 -57.1 -64.5 -72.3 -80.5 -89.2
1 30 -33.6 -39.4 -45.7 -52.4 -59.7 -67.4 -75.5 -84.1 -93.2
40 -36.4 42.8 -49.6 -56.9 -64.8 -73.1 -82.0 -91.3 -101.2
50 -38.8 -45.6 -52.9 -60.7 -69.0 -77.9 -87.4 -97.4 -107.9
60 40.8 -47.8 -55.5 -63.7 -72.4 -81.8 -91.7 -102.2 -113.2
20 -41.4 -48.6 -56.3 -64.7 -73.6 -83.1 -93.1 -103.7 -115.0
25 -44.7 -52.5 -60.9 -69.9 -79.5 -89.8 -100.6 -112.1 -124.2
Partially 30 -46.7 -54.8 -63.6 -73.0 -83.1 -93.8 -105.1 -117.1 -129.8
Enclosed 2 40 -50.7 -59.5 -69.0 -79.3 -90.2 -101.8 -114.1 -127.2 -140.9
50 -54.1 -63.4 -73.6 -84.5 -96.1 -108.5 -121.6 -135.5 -150.2
60 -56.7 -66.6 -77.2 -88.6 -100.9 -113.9 -127.6 -142.2 -157.6
20 48.4 -56.8 -65.8 -75.6 -86.0 -97.1 -108.8 -121.3 -134.4
25 -52.3 -61.4 -71.2 -81.7 -92.9 -104.9 -117.6 -131.1 -145.2
3 30 -54.6 -64.1 -74.3 -85.3 -97.1 -109.6 -122.9 -136.9 -151.7
40 -59.3 -69.6 -80.7 -92.7 -105.4 -119.0 -133.4 -148.7 -164.7
50 -63.2 -74.2 -86.0 -98.8 -112.4 -126.8 -142.2 -158.4 -175.6
60 -66.3 -77.8 -90.3 -103.6 -117.9 -133.1 -149.2 -166.3 -184.2
GCS20002a FL33818 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
CREEKGULF COAST SUPPLY&MANUFACTURING,LLC
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX C
Gable/Hip Roofs in Exposure C Roof slope between 2:12 and 12:12
Mean Basic Wind Speed I mph)
Building Type 'Zone Roof 1�20 130 140' �150 160 170 180 190' 206
Height ft
20 -36.9 -43.3 -50.2 -57.6 -65.6 -74.0 -83.0 -92.5 -102.5
25 -38.5 -45.2 -52.4 -60.2 -68.5 -77.3 -86.7 .-96.6 -107.0
1 30 -40.2 -47.1 -54.7 -62.8 -71.4 -80.6 -90.4 -100.7 -111.6
40 -42.6 -50.0 -58.0 -66.6 -75.8 -85.6 -95.9 -106.9 -118.4
50 -44.7 -52.4 -60.8 -69.8 -79.4 -89.7 -100.5 -112.0 -124.1
60 -46.3 -54.4 -63.0 -72.4 -82.3 -93.0 -104.2 -116.1 -128.7
20 -53.8 -63.2 -73.2 -84.1 -95.7 -108.0 -121.1 -134.9 -149.5
25 -56.2 -66.0 -76.5 -87.8 -99.9 -112.8 -126.5 -140.9 -156.1
Enclosed/ 2 30 -58.6 -68.8 -79.8 -91.6 -104.2 -117.6 -131.8 -146.9 -162.8
Partially Open 40 -62.2 -73.0 -84.6 -97.2 -110.5 -124.8 -139.9 -155.9 -172.7
50 -65.2 -76.5 -88.7 -101.8 -115.9 -130.8 -146.6 -163.4 -181.0
60 -67.6 -79.3 -92.0 -105.6 -120.1 -135.6 -152.0 -169.4 -187.7
20 -64.0 -75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7
25 -66.8 -78.4 -90.9 -104.4 -118.8 -134.1 -150.3 -167.5 -185.6
3 30 -69.7 -81.7 -94.8 -108.8 -123.8 -139.8 -156.7 -174.6 -193.5
40 -73.9 -86.7 -100.6 -115.5 -131.4 -148.3 -166.3 -185.3 -205.3
50 -77.5 -90.9 -105.4 -121.0 -137.7 -155.5 -174.3 -194.2 -215.2
60 -80.3 -94.3 -109.3 -125.5 -142.8 -161.2 -180.7 -201.3 -223.1
20 -43.2 -50.6 -58.7 -67.4 -76.7 -86.6 -97.1 -108.2 719.9
25 -45.1 -52.9 -61.3 -70.4 -80.1 -90.4 -101.4 -113.0 -125.2
1 30 -47.0 -55.1 -64.0 -73.4 -83.5 -94.3 -105.7 -117.8 -130.5
40 -49.9 -58.5 -67.9 -77.9 -88.6 -100.1 -112.2 -125.0 -138.5
50 -52.3 -61.3 -71.1 -81.7 -92.9 -104.9 -117.6 -131.0 -145.2
60 -54.2 -63.6 -73.7 -84.7 -96.3 -108.7 -121.9 -135.8 -150.5
20 -60.1 -70.5 -81.8 -93.9 -106.8 -120.6 -135.2 -150.6 -166.9
25 -62.7 -73.6 -85.4 -98.0 -111.5 -125.9 -141.2 -157.3 -174.3
Partially 2 30 -65.4 -76.8 -89.0 -102.2 -116.3 -131.3 -147.2 -164.0 -181.7
Enclosed 40 -69.4 -81.5 -94.5 -108.5 -123.4 -139.3 -156.2 -174.0 -192.8
50 -72.8 -85.4 -99.0 -113.7 -129.3 -146.0 -163.7 -182.4 -202.1
60 -75.4 -88.5 -102.7 -117.8 -134.1 -151.4 -169.7 -189.1 -209.5
20 -70.2 -82.4 -95.6 -109.7 -124.8 -140.9 -158.0 -176.0 -195.1
25 -73.3 -86.1 -99.8 -114.6 -130.4 -147.2 -165.0 -183.9 -203.7
3 30 -76.5 -89.7 -104.1 -119.5 -135.9 -153.5 -172.0 -191.7 -212.4
40 -81.1 -95.2 -110.5 -126.8 -144.3 -162.9 -182.6 -203.4 -225.4
50 -85.0 -99.8 -115.8 -132.9 -151.2 -170.7 -191.4 L -213.2 -236.2
60 -88.2 -103.5 -120.0 -137.8 -156.7 -177.0 -198.4 1 -221.0 1 -244.9
GCS20002a FL33818 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
CREEKGULF COAST SUPPLY&MANUFACTURING,LLC -�
f Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX C
Gable/Hip Roofs in Exposure D Roof.slo a between 2:12 and 12:12
Mean : Basic Wind Speed m h
Building Type. Zone Roof,, _
Height_ft 120 130�"e` 1'40 150 " 160�" 170 " , ; 180 190 -200
_.s
20 -44.3 -52.0 -60.3 69.2 -78.7 -88.8 -99.6 -111.0 -123.0
25 -45.9 -53.9 -62.5 -71.7 -81.6 -92.1 -103.3 -115.1 -127.5
1 30 -47.5 -55.8 -64.7 -74.3 -84.5 -95.4 -107.0 -119.2 .-132.1
40 -50.0 -58.7 -68.1 -78.1 -88.9 -100.4 -112.5 -125.4 -138.9
50 -52.1 -61.1 -70.9 -81.3 -92.5 -104.5 -117.1 -130.5 -144.6
60 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.1
20 -64.6 -75.8 -87.9 -100.9 -114.8 -129.6 -145.3 -161.9 -179.4
25 -67.0 -78.6 -91.1 -104.6 -119.0 -134.4 -150.7 -167.9 -186.0
Enclosed/ 30 -69.4 -81.4 -94.4 -108.4 -123.3 -139.2 -156.0 -173.9 -192.6
Partially Open 2 40 -72.9 -85.6 -99.3 -114.0 -129.7 -146.4 -164.1 -182.9 -202.6
50 -75.9 -89.1 -103.3 -118.6 -135.0 -152.4 -170.8 -190.4 -210.9
60 -78.3 -91.9 -106.6 -122.4 -139.2 -157.2 -176.2 -196.3 -217.6
20 -76.8 -90.1 -104.5 -119.9 -136.5 -154.0 -172.7 -192.4 -213.2
25 -79.6 -93.4 -108.3 -124.4 -141.5 -159.7 -179.1 -199.5 -221.1
3 30 -82.4 -96.8 -112.2 -128.8 -146.6 -165.4 -185.5 -206.7 -229.0
40 -86.7 -101.8 -118.0 -135.5 -154.1 -174.0 -195.1 -217.4 -240.8
50 -90.3 -105.9 -122.8 -141.0 -160.5 -181.1 -203.1 -226.3 -250.7
60 -93.1 -109.3 -126.7 -145.5 -165.5 -186.8 -209.5 -233.4 -258.6
20 -51.8 -60.8 -70.5 -80.9 -92.1 -103.9 -116.5 -129.8 -143.8
25 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.2
1 30 -55.6 -65.3 -75.7 -86.9 -98.9 -111.6 -125.1 -139.4 -154.5
40 -58.5 -68.7 -79.6 -91.4 -104.0 -117.4 -131.6 -146.6 -162.5
50 -60.9 -71.5 -82.9 -95.1 -108.2 -122.2 -137.0 -152.6 -169.1
60 -62.8 -73.7 -85.5 -98.1 -111.7 -126.0 -141.3 -157.5 -174.5
20 -72.1 -84.6 -98.1 -112.6 -128.2 -144.7 -162.2 -180.7 -200.2
25 -74.8 -87.7 -101.7 -116.8 -132.9 -150.0 -168.2 -187.4 -207.6
Partially 30 -77.4 -90.9 -105.4 -121.0 -137.6 -155.4 -174.2 -194.1 -215.1
Enclosed 2 40 -81.4 -95.6 -110.8 -127.2 -144.8 -163.4 -183.2 -204.1 -226.2
50 -84.8 -99.5 -115.4 -132.4 -150.7 -170.1 -190.7 -212.5 -235.5
60 -87.4 -102.6 -119.0 -136.6 -155.4 -175.5 -196.7 -219.2 -242.9
20 -84.3 -98.9 -114.7 -131.7 -149.8 -169.1 -189.6 -211.3 -234.1
25 -87.4 -102.6 -118.9 -136.5 -155.4 -175.4 -196.6 -219.1 -242.7
3 30 -90.5 -106.2 -123.2 -141.4 -160.9 -181.6 -203.6 -226.9 -251.4
40 -95.2 -111.7 -129.6 -148.7 -169.2 -191.0 -214.2 -238.6 -264.4
50 -99.1 -116.3 -134.9 -154.8 -176.2 -198.9 -223.0 -248.4 -275.2
60 -102.2 -120.0 -139.1 -159.7 -181.7 1 -205.1 -230.0 -256.2 1 -283.9
GCS20002a FL33818 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other
product attributes that are not specifically addressed herein.