HomeMy WebLinkAboutEnergy Efficiency Code 5-14-159z
FORM 46b--10 �a� �� ��l NOS-- olgL
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: ETTER RESIDENCE
Builder Name:
Street: LOT 560 NETTLES BLVD.
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (2046.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0 1918.20 ft2
b. Frame - Wood, Exterior
R=13.0 128.00 f12
3. Number of units, if multiple family 1
c. WA
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1704.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=19.0 1704.00 ft2
6. Conditioned floor area above grade (ft2) 1704
b. N/A
R= ft2
Conditioned floor area below grade (W) 0
c.
R= ft2
11. Ducts
R ft2
7. Windows(153.5 sgft.) Description Area
a. Sup: Main, Ret: Main, AH: Main
6 340.8
a. U-Factor: Sgl, U=0.29 153.50 ft2
SHGC: SHGC=0.29
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
36.0 SEER:16.00
c. U-Factor. NIA ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
36.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.290
14. Hot water systems
a. Electric Tankless
Cap: 1 gallons
8. Floor Types (1704.0 sgft.) Insulation Area
EF: 0.990
a. Slab -On -Grade Edge Insulation R=0.0 1704.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.090 Total Proposed Modified Loads: 28.06
PASS
Total ndar eferenc
oads: 36.59
I hereby certify that the plans and specifications c�ered
Review of the plans and
UE ST9?�p
this calculation are in compliance with the Florida Energy
specifications covered by this
OQ`
.y _
Code.
calculation indicates compliance
PREPARED BY: %�XSt�(d �i/1�l . ��% ��/�
DATE:
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
r
Q
1 hereby certify that this bu' ing, as designed, is in compliance
Florida Statutes.
lAl
COD
with the Florida Energy C Ile.
WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
d
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
5/5/20151:34 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 77
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows*"
Description
a. U-Factor:
Sgl, U=0.29
SHGC:
SHGC=0.29
b. U-Factor:
N/A
SHGC:
c. U-Factor.
N/A
SHGC:
d. U-Factor.
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
LOT 560 NETTLES BLVD., FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0
1918.20 ft'
b. Frame - Wood, Exterior
R=13.0
128.00 ft
1
c. WA
R=
ft2
2
d.. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
No
a. Under Attic (Vented)
R=19.0
1704.00 ft2
1704
b. N/A
R=
ft2
Area
c. WA
R=
ft2
153.50 ft2
Ducts
R ft2
a.
a. Sup: Main, Ret: Main, AH: Main
6 340.8
ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
36.0 SEER:16.00
ft2
1.000 ft.
0.290
8. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1704.00 ft2
b. N/A R= ft2
c. N/A R= ft2
13. Heating systems
a. Electric Strip Heat
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final i9vection. Otherwise, a new EPL Display Card will be completed
based on installed Code pliant features.
Builder Signature: Date:- Ua4,1o�,�
Address of New Home/ .(,% Al�1 6/, City/FL Zip:
kBtu/hr Efficiency
36.0 COPA .00
Cap: 1 gallons
EF: 0.99
CF, Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
ETTER RESIDENCE
User
1
ST. LUCIE COUNTY
Single-family
New (From Plans)
Bedrooms: 2
Conditioned Area: 1704
Total Stories: 2
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
LOT 560 NETTLES BL
ST. LUCIE
FT. PIERCE,
FL,
CLIMATE
Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL ST_LUCIE_CO_INTL 2 39 90
70
75 722
62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1704 13632
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
1704 13632 Yes 1
2
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 227 ft 0
1704 ft2
____
0 0 1
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip
Metal 1846 ft2 0 ft2 Medium
0.96
No 0.9
No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300
1704 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac
Truss Type
1
Under Attic (Vented)
Main 19 1704 ft2
0.11
Wood
5/5/2015 1:34 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
WALLS
v
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
Space
1
S
Exterior
Concrete Block - Int Insul
Main
5
10
8
80.0 ft2
0 0.75
0
2
W
Exterior
Concrete Block - Int Insul
Main
5
4
8
32.0 ft2
0 0.75
0
3
S
Exterior
Concrete Block - Int Insul
Main
5
11.5
8
92.0 ft2
0 0.75
0
4
W
Exterior
Concrete Block - Int Insul
Main
5
4
8
32.0 ft2
0 0.75
0
5
W
Exterior
Concrete Block - Int Insul
Main
5
16
8
128.0 ft2
0 0.75
0
6
E
Exterior
Concrete Block - Int Insul
Main
5
16
8
128.0 ft2
0 0.75
0
7
W
Exterior
Concrete Block - Int Insul
Main
5
14
8
112.0 ft2
0 0.75
0
8
W
Exterior
Concrete Block - Int Insul
Main
5
14
8
112.0 ft2
0 0.75
0
9
N
Exterior
Concrete Block - Int Insul
Main
5
10
8
80.0 ft2
0 0.75
0
10
NE
Exterior
Concrete Block - Int Insul
Main
5
10
8
80.0 ft2
0 0.75
0
11
NE
Exterior
Concrete Block - Int Insul
Main
5
9
8
72.0 ft2
0 0.75
0
12
NE
Exterior
Concrete Block - Int Insul
Main
5
10
8
80.0 ft2
0 0.75
0
13
E
Exterior
Concrete Block - Int Insul
Main
5
13
8
104.0 ft2
0 0.75
0
14
E
Exterior
Concrete Block - Int Insul
Main
5
A
8
32.0 ft2
0
0 0.75
0
15
E
Exterior
Concrete Block - Int Insul
Main
5
8
8
64.0 ft2
0 0.75
0
16
S
Exterior
Frame - Wood
Main
13
16
8
128.0 ft2
0.23 0.75
0
17
S
Exterior
Concrete Block - Int Insul
Main
5
10.2
8.5
86.7 ft2
0 0.75
0
18
W
Exterior
Concrete Block - Int Insul
Main
5
10
8.5
85.0 ft2
0 0.75
0
19
W
Exterior
Concrete Block - Int Insul
Main
5
12
8.5
102.0 ft2
0 0.75
0
20
NE
Exterior
Concrete Block - Int Insul
Main
5
14
8.5
119.0 ft2
0 0.75
0
21
NE
Exterior
Concrete Block - Int Insul
Main
5
12
8.5
102.0 ft2
0 0.75
0
22
E
Exterior
Concrete Block - Int Insul
Main
5
8
8.5
68.0 ft2
0 0.75
0
23
W
Exterior
Concrete Block - Int Insul
Main
5
9
8.5
76.5 ft2
0 0.75
0
24
NE
Exterior
Concrete Block - Int Insul
Main
5
6
8.5
51.0 ft2
0 0.75
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
S
Wood
Main
None
.46
3
7
21 ft2.
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC
U-Factor
SHGC
Area
Depth
Separation
Int Shade
Screening
1
S 3
Metal Single (Tinted)
Yes
0.29
0.29
12.0 ft2
1 ft 0 in
0 ft 0 in
Drapes/blinds
None
2
W 4
Metal Single (Tinted)
Yes
0.29
0.29
22.5 ft2
1 ft 0 in
0 ft 0 in
Drapes/blinds
None
3
E 6
Metal Single (Tinted)
Yes
0.29
0.29
10.0 ft2
1 ft 0 in
0 ft 0 in
Drapes/blinds
None
4
W 7
Metal Single (Tinted)
Yes
0.29
0.29
22.5 ft2
1 ft 0 in
0 ft 0 in
Drapes/blinds
None
5
W 8
Metal Single (Tinted)
Yes
0.29
0.29
4.0 ft2
1 ft 0 in
0 ft 0 in
Drapes/blinds
None
6
N 9
Metal Single (Tinted)
Yes
0.29
0.29
12.0 ft2
1 ft 0 in
0 ft 0 in
Drapes/blinds
None
7
NE 11
Metal Single (Tinted)
Yes
0.29
0.29
6.0 ft2
1 ft 0 in
0 ft 0 in
Drapes/blinds
None
8
NE 12
Metal Single (Tinted)
Yes
0.29
0.29
15.0 ft2
1 ft 0 in
0 ft 0 in
Drapes/blinds
None
9
E 15
Metal Single (Tinted)
Yes
0.29
0.29
19.5 ft2
1 ft 0 in
0 ft 0 in
Drapes/blinds
None
10
W 19
Metal Single (Tinted)
Yes
0.29
0.29
15.0 ft2
1 ft 0 in
0 ft 0 in
Drapeslblinds
None
5/5/20151:34 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
WINDOWS -
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Area Depth Separation Int Shade
Screening
11
12
NE 20 Metal Single (Tinted) Yes
NE 21 Metal Single (Tinted) Yes
0.29 0.29 12.0 ft2 1 ft 0 in 0 ft 0 in Drapes/blinds
0.29 0.29 , 3.0 ft2 1 ft 0 in 0 ft 0 in Drapes/blinds
None
None
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Best Guess
.0005
2234.8 122.69 230.73 .4494 9.8363
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Strip Heat
None
COP: 1 36 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit
None
SEER: 16 36 kBtu/hr 1080 cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric Tankless
Exterior
0.99 1 gal 50 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
#
— Supply —
Location R-Value Area
— Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
Main 6 340.8 ft
Main
85.2 ft2 Default Leakage Main (Default) (Default)
1 1
5/5/2015 1:34 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6
I
�
1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Heat ng Jan
Feb
Mar
Apr
Apr
I
I May
Jun
rl Jul
Aug
ri
ri
Sep
j Oct
OctXi
Nov
Nov
Dec
Dec
Venting Jan
Feb
Mar
Jun
Jul
Aug
Sep l�J
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
5/5/20151:34 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6
FORM 405-10
1
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: LOT 560 NETTLES BLVD. PERMIT #:
FT. PIERCE, FL,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
5/5/20151:34 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6