Loading...
HomeMy WebLinkAboutEnergy Efficiency Code 5-7-2014•S FORM'405 10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ETTER RESIDENCE Builder Name: Street: LOT 560 NETTLES BLVD. Permit Office: - ST. LUCIE COUNTY -City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (2046.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1918.20 ft2 b. Frame - Wood, Exterior R=13.0 128.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1704.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1704.00 ft2 6. Conditioned floor area above grade (ft2) 1704 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(153.5 sqft.) Description Area a. Sup: Exterior, Ret: RoomslnBlockl, AH: Roomsin 6 340.8 a. U-Factor: Sgl, U=0.29 153.50 ft2 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 36.0 SEER:15.50 c. U-Factor: N/A ft2 SHGC: I'Ir Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 36.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (1704.0 sqft.) Insulation Area EF: 0.990 a. Slab -On -Grade Edge Insulation R=0.0 1704.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.090 Total Proposed Modified Loads: 27.07 PASS Total itandard Refer nce Loads: 36.59 IN I hereby certify that the plans and specificatirncov red y Review of the plans and ��1 STthis calculation are in compliance with the FlEner specifications covered by this .�+`_ �0�, Code, calculation indicates compliance ` y "�i�,'';; - �.��` ,� �njG� with the Florida Energy Code. « ` PREPARED BY: 1F'S/►J'l��'!% f�Grs Before construction is completed DATE: W2�2/1V this building will be inspected for compliance with Section 553.908 I hereby certify that this b ' ing, as designed, is in compliance Florida Statutes. 1�C with the Florida Energy o e. ��'�'" COD WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 4/23/2014 11:33 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 74 The lower the EnergyPerformance Index, the more efficient the home. LOT 560 NETTLES BLVD., FT. PIERCE, FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Sgl, U=0.29 SHGC: SHGC=0.30 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1918.20 ft2 b. Frame - Wood, Exterior R=13.0 128.00 ft2 1 c. N/A R= ft2 2 d. N/A R= ft2 10. Ceiling Types Insulation Area No a. Under Attic (Vented) R=30.0 1704.00 ft2 1704 b. N/A R= ft2 Area c. N/A R= ft2 153.50 ft2 11. Ducts a. Sup: Exterior, Ret: RoomslnBlock1, AH: Roomsln R ft2 6 340.8 ft2 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 36.0 SEER:15.50 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= ft2 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 36.0 COPA.00 1.000 ft. 0.300 Area 14. Hot water systems 1704.00 ft2EF: a. Electric Cap: 1 gallons 0.91 ft2 b. Conservation features ft2 None 15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code Ampliant features. Builder Signature: ` Date: Address of New Ho City/FL Zip:` SOD *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "`Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: ETTER RESIDENCE FLProp2010 1 ST. LUCIE COUNTY Single-family New (From Plans) Bedrooms: 2 Conditioned Area: 1704 Total Stories: 2 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address LOT 560 NETTLES BL ST. LUCIE FT. PIERCE, FL, CLIMATE Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 1704 13632 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 RoomslnBlockl 1704 13632 Yes 2 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio RoomslnBlockl 227 ft 0 1704 ft2 _M 0 0 1 ROOF # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emift Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 1846 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1704 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) RoomslnBlockl 30 1704 ft2 0.11 Wood 4/23/201411:33 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 ` WALLS # Omt Adjacent Space To Wall Type1 Cavity Width Height Sheathing Framing Solar Below S Exterior Concrete Block - Int InsGIoomsInBloc 5 10 8 80 ftz 0 0.75 0 2 W Exterior Concrete Block - Int InSBIoomsInBloc 5 4 8 32 ft2 0 0.75 0 3 S Exterior Concrete. Block - Int Ins8l00mSInPloc 5 11.5 8 92 ft2 0 0.75 0 4 W Exterior Concrete Block - Int Ins6l00mSlnBloc 5 4 8 32 ft2 0 0.75 0 5 W Exterior Concrete Block - Int Ins13oomsInBIoc 5 16 8 128 ft2 0 0.75 0 6 E Exterior Concrete Block - Int Ins5l00mslnBloc 5 16 8 128 ft2 0 0.75 0 7 W Exterior Concrete Block - Int InsftomsInBIoc 5 14 8 112 ft2 0 0.75 0 8 W Exterior Concrete Block - Int InsEloomsInBloc 5 14 8 112 ft2 0 0.75 0 9 N Exterior Concrete Block - Int lnSBloomsInBloc 5 10 8 80 ft2 0 0.75 0 10 NE Exterior Concrete Block - Int InsBIooms1nBIoc 5 10 8 80 ft2 0 0.75 0 11 NE Exterior Concrete Block - Int InsI1oomsInBloc 5 9 8 72 ft2 0 0.75 0 12 NE Exterior Concrete Block - Int lnsBloomsinBloc 5 10 8 80 ft2 0 0.75 0 13 E Exterior Concrete Block - Int InS5Iooms1nBloc 5 13 8 104 ft2 0 0.75 0 14 E Exterior Concrete Block - Int InsRoomsInBloc 5 4 8 32 ft2 0 0 0.75 0 15 E Exterior Concrete Block - Int InSBIoomsInBloc 5 8 8 64 ft2 0 0.75 0 16 S Exterior Frame - Wood RoomslnBloc 13 16 8 128 ft2 0.23 0.75 0 17 S Exterior Concrete Block - Int Ins13oomslnBloc 5 10.2 8.5 86.69999 0 0.75 0 18 W Exterior Concrete Block - Int InsBloomslnBloc 5 10 8.5 85 ft2 0 0.75 0 19 W Exterior Concrete Block - Int InsfoomslnBloc 5 12 8.5 102 ft2 0 0.75 0 20 NE Exterior Concrete Block - Int InsBloomslnBloc 5 14 8.5 119 ft2 0 0.75 0 21 NE Exterior Concrete Block - Int InsBIooms1nBloc 5 12 8.5 102 ft2 0 0.75 0 22 E Exterior Concrete Block - Int InsBloomslnBloc 5 8 8.5 68 ft2 0 0.75 0 23 W Exterior Concrete Block - Int lnsl loomslnBloc 5 9 8.5 76.5 ft2 0 0.75 0 24 NE Exterior Concrete Block - Int InsBloomslnBloc 5 6 8.5 51 ft2 0 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood RoomslnBloc None 0.460000 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall . Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation int Shade Screening 1 S 3 Metal Single (Tinted) Yes 0.29 0.3 N 12 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 2 W 4 Metal Single (Tinted) Yes 0.29 0.3 N 22.5 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 3 E 6 Metal Single (Tinted) Yes 0.29 0.3 N 10 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 4 W 7 Metal Single (Tinted) Yes 0.29 0.3 N 22.5 ft2 1 ft 0 in 0 It 0 in HERS 2006 None 5 W 8 Metal Single (Tinted) Yes 0.29 0.3 N 4 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 6 N 9 Metal Single (Tinted) Yes 0.29 0.3 N 12 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 7 NE 11 Metal Single (Tinted) Yes 0.29 0.3 N 6 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 8 NE 12 Metal Single (Tinted) Yes 0.29 0.3 N 15 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 4/23/201411:33 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Storms Area Depth Separation Int Shade Screening 9 10 11 12 E 15 Metal Single (Tinted) Yes W 19 Metal Single (Tinted) Yes NE 20 Metal Single (Tinted) Yes NE 21 Metal Single (Tinted) Yes 0.29 0.3 N 19.5 ft2 1 ft 0 in 0 ft 0 in 0.29 0.3 N 15 ft2 1 ft 0 in 0 ft 0 in 0.29 0.3 N 12 ft2 1 ft 0 in 0 ft 0 in 0.29 0.3 N 3 ft2 1 ft 0 in 0 ft 0 in HERS 2006 HERS 2006 HERS 2006 HERS 2006 None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 BySpaces Proposed SLR 0.000360 1609.0 88.335 166.12 0.3235 7.0821 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP: 1 36 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 15.5 36 kBtu/hr 1080 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Exterior 0.9108 1 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS # — Supply - -- -- Return --- Air Percent Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF HVAC # Heat Cool 1 Exterior 6 340.8 ft RoomslnBloc 85.2 ft2 DSE=0.88 RoomslnBl 0.0 cfm 0.00 % 0.00 0.60 1 1 4/23/2014 11:33 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolln Vent JanX� Feb Mar IAI Apr Apr May M:y Jun Jun Jul XX Julr AugX� Sep XX Oct No �X� Nov XX Dec ngXj X� Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/23/2014 11:33 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405- i0' Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: LOT 560 NETTLES BLVD. PERMIT #: FT. PIERCE, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 4123/201411:33 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6