PROPERTY INFORMATION
Address: 560 Nettles Blvd
City I State / Zip: Jensen Beach, FI 34957
Parcel #: 4502-501-0746-000/2
Zoning: HIRD
REVIEW COMMENTS
Page 1
Owner(s):
John A Etter (Tr) / Ruth E Etter (Tr)
Jurisdiction: SAINT LUCIE COUNTY
Lot#:
APPLICATION INFORMATION
Permit Number: 1405-0142 Stories:
Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
CONTRACTOR INFORMATION
Contractor Name: James W Newman
Business Name:
Jwn Construction Inc
Business Addr:
1701 Se Carvaldo St
City / State / Zip:
Port St Lucie, FI 34983
REVIEWS AND COMMENTS
Review Type
DOCUMENTS MISSING
5/12/2014 Comment:
5/12/2014 Comment:
5/12/2014 Comment:
5/22/2014 Comment:
ENVIRONMENTAL REVIEW
Comment:
FRONT COUNTER REVIEW
Comment:
PLANS EXAMINER REVIEW
Comment:
5/29/2014
5/29/2014 Comment:
Comment:
5/29/2014
5/29/2014 Comment:
Block:
Automatic Sprinkler System? No
Fax Number: 772-871-9500
Email: Jwnconstruction@Bellsouth
.Net
Status Reviewed By Date Started Date Completed Date Released
PENDING
LETTER OF APPROVAL NETTLES HOA.
i
THE CONTRACTOR/AGENT IS REQUIRED TO SIGN THE FLOOD HAZARD MEMO AT TIME OF PICK UP.
DEMOLITION PERMIT MH
VEGETATION PERMIT IN DRAWER UNDER (E) N FEE
COMPLETE Ben Balcer 5/20/2014 5120/2014
COMPLETE Angela Huff 5/9/2014 5/9/2014 5/9/2014
INCOMPLETE Ed Roseberry 5/29/2014
THE PARKING AREA, ENCLOSED BY ROLL UP DOORS/SHUTTERS, DESIGNATED CARPORT IS ACTUALLY BY
DEFINITION A GARAGE, AND MUST MEET REQUIREMENTS FOR A GARAGE BELOW BASE FLOOD
ELEVATION, PER R309.2
ELECTRIC ROLL UP DOOR/SHUTTER CANNOT BE INSTALLED ON FRONT OF GARAGE BECAUSE IT
ELIMINATES THE REQUIRED PARKING AREA.
IF THE ROLL UP DOORISHUTTER ON THE LEFT SIDE OF GARAGE REMAINS, THEN HYDRO VENT
REQUIREMENTS OF R322.2.2 ARE APPLICABLE. THE ROLL UP DOOR/SHUTTER REMOVED FROM THE
FRONT OPENING CAN SERVE AS 1 HYDRO OPENING, WITH 1 MORE REQUIRED ON A DIFFERENT EXTERIOR
WALL. IF BOTH DOORS/SHUTTERS ARE REMOVED, THE CARPORT DESIGNATION IS CORRECT AND NO
HYDRO VENTS ARE REQUIRED.
OUTSWING EGRESS DOOR IS PROHIBITED FROM SWINGING OVER STEP DOWN EXCEEDING 1 1/2 "
BELOW THE TOP OF THRESHOLD, PER R311.3.1
jGr ,tzG2% 'Ott
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue.
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462.6443
REVIEW COMMENTS
Page 2
5/29/2014 Comment: PLEASE INCLUDE 2 COPIES OF PRODUCT APPROVAL,REFERENCED IN AFFIDAVIT WITH INSTALLATION
REQUIREMENTS HIGHLIGHTED, FOR SKYLIGHT.
5/29/2014 Comment: PLEASE NOTE ALL MATERIALS USED IN GARAGE SEPERATION FRAMED WALL MUST BE FLOOD
RESISTANT MATERIALS.
ZONING REVIEW COMPLETE Lydia Galbraith 5/12/2014 5112/2014 5112/2014
Comment: