Loading...
HomeMy WebLinkAboutTruss A Lumber designjvalues are in accordance with ANSI/TPI 1-200TEMED A-1 ROOF These truss designs rely on lumber values established by Whers. TRU5,5EIS JUN 2 7 2014 A FLORIDA CORPORATION e HHUTTING j St—� 1e Cou RE: Job 58824 A-1 Roof TrusaSq(sFL 4451 St Lucie Blvd Site Information: Fort Pierce,FL 34946 Customer Info: JWN CONSTRUCTION INC. Project Name: ETTER RES Iot/Block: Model: ETTER RESIDENCE Address: LOT 560 NETTLES ISLAND, JENSEN BEACH)division: City: County: St Lucie State: FL Name Address and License#of Structural Engineer of Record, If there is one,for the building. Name: SHAWN M STAMBAUGH, PE License#: 33467 Address: 3001 PGA BLVD SUITE 203 City: PALM BEACH GARDENS, FL General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2010/TP12007 Design Program: MiTek 20/20 7.5 Wind Code:ASCE 7-10 Wind Speed: 165 MPH Roof Load: 55.0 psf Floor Load: 65.0 psf This package includes 96 individual, dated Truss Design Drawings and 0 Additional Drawings. With my-seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules, No. Seal# Truss Name Date No. Seal# Truss Name Date No. Seal# Truss Name Date 1 A0357866 A01 G 6/20/14 13 A0357877 B06 6/20/14 25 A0357890 CJ3C 6/20/14 2 A0357888 CJ3A 6/20/14 14 A0357878 B07 6/20/14 26 A0357891 CJ4 6/20/14 3 A0357867 A02 6/20/14 15 A0357879 808 6/20/14 27 A0357892 CJ4A 6/20/14 4 A0357868 A03 6/20/14 16 A0357880 B09 6/20/14 28 A0357893 CJ5 6/20/14 5 A0357869 A04 6/20/14 17 A0357881 CA 6/20/14 29 A0357894 CJ5C 6/20/14 6 A0357870 A05 6/20/14 18 A0357882 CAA 6/20/14 30 A0357895 CJ6 6/20/14 7 A0357871 A06G 6/20/14 19 A0357883 CAB 6/20/14 31 A0357896 CJ6A 6120/14 8 A0357872 B01 G 6/20/14 20 A0357884 CJ 1 C 6/20114 32 A0357897 D01 G 6/20/14 9 A0357873 B02 6/20/14 21 A0357885 CJ2 6/20/14 33 A0357898 D02 6/20/14 10 A0357874 B03 6/20/14 22 A0357886 CJ2A 6/20114 34 A0357899 D03 6/20/14 11 A0357875 804 6/20/14 23 A0357887 CJ3 6/20/14 35 A0357900 D03D 6/20/14 12 A0357876 1 805 6/20/14 24 A0357889 CJ313 1 6/20/14 136 IA0357927 I HJ5 6/20114 Julius Lee,PE!Florida Certification Number 34869 The truss drawing(s) referenced have been prepared by MiTek 1109 Coastal Bay,Boynton Beach,FL 33435 Industries, Inc. under my direct supervision based on the parameters 6/20/14 provided by A-1 Roof Trusses, Ltd. v, K Truss Design Engineer's Name: Julius Lee My license renewal date for the state of Florida is February 28,2015. ]J \GENSF NOTE: The seal on these drawings indicate acceptance of * 34869 professional engineering responsibility solely for the truss _-U components shown. The suitability and use of this component for any particular building is the responsibility of the building �� STATE OF _4u� designer, per ANSI/TPI-1 Sec. 2. /011111100 Page 1 of 2 1109 COASTAL BAY BOYNTON BC, FL 33435 612012014 Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3 designs rely on lumber values established by others. A-1 ROOF These truss TRUSSES A FLORIDA CORPORATION RE: Job 58824 No. Seal# Truss Name Date No. Seal# Truss Name Date 37 A0357928 HJ7 6/20/14 75 A0357905 F05 6120/14 38 A0357929 HJ7A 6/20/14. 76 A0357906 F06 6/20/14 39 A0357930 HJA 6/20/14 77 A0357907 F07 6/20/14 40 A0357931 HJB 6/20/14 78 A0357908 F08 6120114 41 A0357932 HJC 6/20114 79 A0357909 F09 6/20/14 42 A0357933 HJD 6/20/14 80 A0357910 F10 6/20/14 43 A0357934 J5 6/20/14 81 A0357911 F11 6/20/14 44 A0357935 J7 6/20/14 82 A0357912 F12 6/20/14 45 A0357936 JA 6/20/14 83 A0357913 F13 6/20/14 46 A0357937 JB 6/20/14 84 A0357914 F14 6/20/14 47 A0357938 JC 6/20/14 85 A0357915 F15 6/20/14 48 A0357939 JD 6/20/14 86 A0357916 F16 6/20/14 49 A0357940 JE 6/20/14 87 A0357917 F17 6120/14 50 A0357941 JF 6/20/14 88 A0357918 F18G 6/20/14 51 A0357942 JFG 6/20/14 89 A0357919 F19 6/20/14 52 A0357943 JH 6/20/14 90 A0357920 F20 6/20114 53 A0357944 JI 6/20/14 91 A0357921 F21G 6/20/14 54 A0357945 JK 6/20/14 92 A0357922 F22- 6/20/14 0000 55 A0357946 JM 6/20/14 93 A0357923 F23 6/20/14 56 A0357947 JN 6/20/14 94 A0357924 F24G 6/20/14 57 A0357948 JO 6/20/14 95 A0357925 F25G 6/20/14 58 A0357949 JP 6/20/14 96 A0357926 F26G 6/20/14 59 A0357950 JQ 6/20/14 60 A0357951 A 6/20/14 i 61 A0357952 JS 6/20/14 i 62 A0357953 JT 6/20/14 63 A0357954 JU 6/20/14 64 A0357955 JV 6/20/14 65 A0357956 JW 6/20/14 66 A0357957 JX 6/20/14 67 A0357958 JY 6/20/14 68 A0357959 " JZ 6/20/14 69 A0357960 VM2 6/20/14 70 A0357961 VM4 6/20/14 71 A0357901 F01 6/20/14 72 A0357902 F02 6/20/14 73 A0357903 F03 6/20/14 74 A0357904 F04 6/20/14 Page 2 of 2 P-0151 NSs fuss ype ty y2 Job Reference o tional A0357866 4 A01G Roof Special Girder 1 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:05 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=\Mutzsz-RgZcfDxpFCYIG51?2?Eo8gEpUSyu?mz4NKa 7-0-11 10-4-3 15-8-14 20-11-11 27-1-4 2LI11-4, 7-0-11 3-3-9 5 4-11 5-2-13 6-1-9 1-9-0 ' Scale=1:47.1 1.50112 4x6= 2.94 F12 3x4 3 3x = 3x8 MT 2 H= 2 4 5 3x4= 6 4x8= 7 a1 LLI d d 12 11 10 9 4x12= 4x8- 3x6 11 12x18 MT201 - 10x10= 3x6 11 -10- 7-0-11 1 9-10-7 1 4 3 15-8-14 20-11-11 27-1-4 28-10-4 1 6-2-5 2-9-12 0-5- 2 5 4-11 5-2-13 6-1-9 1-9-0 Plate Offsets(X Y)- [1:0-0-9 Edgel [1:1-2-13 0-2-21 [7:0-6-5 0-2-10] r10:0-5-0 0-6-121 [11:0-9-0 0-6-41 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.82 Vert(LL) 0.68 9-10 >500 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.87 Vert(TL) -1.22 9-10 >279 240 MT20H 187/143 BCLL 0.0 ' Rep Stress Incr NO WB 0.36 Horz(TL) 0.14 8 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:327 lb FT=0% LUMBER- TOP CHORD 2x4 SP M 30'Except- 7)Plate(s)at joint(s)10 checked for a plus or minus 1 T1:2x4 SP No.2 BOT CHORD degree rotation about its center. BOT CHORD 2x8 SP No.1 'Except' 1-18=-341/694,1-1=-2487/5003, 8)This truss has been designed for a 10.0 psf bottom 132:2x8 SP 2400F 1.8E 1-28=-5004/10284,12-28=-5004/10284, chord live load nonconcurrent with any other live WEBS 2x4 SP No.3'Except' 1 1-1 2=-5004/1 02 84,1 1-2 9=-6 844/1 3 645, loads. W4,W3:2x6 SP No.2 29-30=6844/13645,1 0-3 0=-6 844/1 3 64 5, 9)'This truss has been designed for a live load of BRACING- 1 0-31=6250/1 21 23,31-32=-6250/12123, 20.Opsf on the bottom chord in all areas where a TOP CHORD 9-32=-6250/12123,9-33=-6250/12123, rectangle 3-6-0 tall by 2-0-0 wide will fit between the Structural wood sheathing directly applied or 3-0-6 oc 33-34=6250/12123,34-35=-6250/12123, bottom chord and any other members. purlins. 7-35=-6250/12123 10)Provide mechanical connection(by others)of BOT CHORD WEBS truss to bearing plate capable of withstanding 100 lb Rigid ceiling directly applied or 7-5-4 oc bracing. 2-12=7837/375,3-11=-1839/3691, uplift at joint(s)except at=lb)8=1190,1=1671. 4-11=-2582/1291,4-10=-36/343, 11)"Semi-rigid pitchbreaks with fixed heels"Member REACTIONS. (lb/size) 6-10=-702/1709,6-9=-891/486, end fixity model was used in the analysis and design 8 = 2172/1-1-5 (min.0-1-8) 2-11=-686/1 393 of this truss. 1 = 354310-8-3 (min.0-2-1) 12)Hanger(s)or other connection device(s)shall be Max Horz NOTES- provided sufficient to support concentrated load(s) 1 = 73(LC 8) 1)2-ply truss to be connected together with 12d 382 lb down and 480 lb up at 5-7-0,106 lb down and Max Uplift (0.131"x3.25")nails as follows: 115 lb up at 11-3-15,113 lb down and 119 lb up at 8 = -1190(LC 5) Top chords connected as follows:2x4-1 row at 0-7-0 13-7-10,192 lb dawn and 171 lb up at 15-11-6,151 1 = -1671(LC 4) oc clinched. lb down and 144 lb up at 18-3-1,109 lb dawn and Bottom chords connected as follows:2x8-2 rows 116 lb up at 20-6-12,90 lb down and 88 lb up at FORCES. (lb) staggered at 0-9-0 oc clinched. 22-10-8,and 77 lb down and 58 lb up at 25-2-3,and Max.Comp./Max.Ten.-All forces 250(lb)or less Webs connected as follows:2x4-1 row at 0-9-0 oc 179 lb down and 261 lb up at 27-0-2 on top chord, except when shown. clinched,2x6-2 rows staggered at 0-9-0 oc clinched. and 34 lb down and 221 lb up at 5-7-0,2379 lb down TOP CHORD 2)All loads are considered equally applied to all plies, and 1385 lb up at 10-3-12,292 lb down and 150 lb 1-17=-744/367,1-1=-4712/2355, except if noted as front(F)or back(B)face in the up at 11-3-15,227 lb down and 118 lb up at 13-7-10, 1-1 9=-1 0645/5237,2-19=-10587/5290, LOAD CASE(S)section.Ply to ply connections have 55 lb down at 15-11-6,35 lb down and 3 lb up at 2-3=-11576/5913,3-20=-11294/5793, been provided to distribute only loads noted as(F)or 18-3-1,19 lb down and S lb up at 20-6-12,10 lb 20-21=-1 1 31 5/5794,4-21=-11353/5798, (B),unless otherwise indicated. down and 13 lb up at 22-10-8,and 3 lb down and 35 4-5=-13750/6982,5-22=-13757/6978, 3)Unbalanced roof live loads have been considered lb up at 25-2-3,and 121 lb up at 27-0-2 on bottom 22-23=-1 37 92/69 86,6-23=-13798/6987, for this design. chord. The design/selection of such connection 6-24=12217/6350,24-25=-12222/6348, 4)Wind:ASCE 7-10;Vult=165mph(3-second gust) device(s)is the responsibility of others. 7-25=-12250/6342,7-26=-12305/6366, Vasd=128mph;TCDL=5.Opsf;BCDL=S.Opsf;h=20ft; 13)Warning:Additional permanent and stability 26-27=-1 226 9/6 336,7-27=-1228516333 Cat.ll;Exp D;Encl.,GCpi=0.18;MWFRS(envelope); bracing for truss system(not part of this component BOT CHORD cantilever left and right exposed;end vertical left design)is always required. 1-18=-341/694,1-1=-2487/5003, exposed;Lumber DOL=1.60 plate grip DOL=1.60 1-28=5 0 04/1 0284,12-28=-5004/10284, 5)All plates are MT20 plates unless otherwise 11-1 2=-5004/10284,11-29=-6844/13645, indicated. LOAD CASE(S) 29-30=-6844/13645,10-30=-6844/13645, 6)Plate(s)at joint(s)3,5,2,12,4,6,9,11,7,1 and 1 Standard 10-31=-6250/12123,31-32=-6250/12123, checked for a plus or minus 0 degree rotation about 1)Dead+Roof Live(balancdullus Lee,P.E. #34869 9-32=6250/12123,9-33=-6250/12123, its center. Increase=1.25,Plate Incrd109 Coastal Bay Continued on page 2 Uniform Loads(plf) Boynton Beach,FL 33435 .0 A, Job toss cuss Type ty y Ao3s7ass 2 Job Reference(optional) 58824 �"01G Roof Special Girder 1 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:05 2014 Page 2 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=Wtutzsz RgZcfDxpFCYjG51?2?Eo8gEpUSyu?mz4NKa LOAD CASE(S) Standard Uniform Loads(plf) Vert:1-3=-90,3-27=-90,7-27=-30,1-9=-20 Concentrated Loads(lb) Vert:4=-123(B)10=-32(B)11=-2379(B)19=128(B) 20=37(B)21=-43(B)22=-82(B)23=40(B)24=4(B) 25=51(B)26=261(B)28=-34(B)29=292(B) 30=227(B)31=20(B)32=-7(B)33=8(B)34=21(B) 35=65(B) Julius Lee;P.E. #34869 1109 Coastal Bay Boynton Beach,FL"33435 Job toss runs Type y y A0357867 58824 A02 Roof Special 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,Fl.34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:05 2014 Page 1 ID:YRb6ZZgQrA7iabOgpSwopfz7lH_Wtutzsz—RgZcfDxpFCYjG51_v?Gy8aOpUSyu?mz4NKa 6 6-13 11-6-5 16�-13 22-8-14 28-4-14 6 6-13 4-11-7 5-0-8 6-2-2 5-8-0 Scale:1/4"=l' 4x6 1.50112 = 2.94 F12 3 3x4= 3x4 4 5x10 MT201 : 3.00 12 2 5 Ivi v1 6 v d d 11 10 9 8 7 3x6 3x8 11 1.5x4 11 3x8= 5x10 MT20H WB= 1.5x4 11 3x8= 4x4= -10- 6-6-13 11-6-5 15§113 22-8-14 28-4-14 -10- 5-84 4-11-7 5-0.8 6-2-2 54!1-0 Plate Offsets(X Y)— [1:0-0-4 1-9-51 [1:0-4-1 Edge] r5:0-6-8,0-3-01 LOADING(psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.89 Vert(LL) 0.63 7-8 >540 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.73 Vert(TL) -0.83 7-8 >411 240 MT20H 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.74 Horz(TL) 0.16 6 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:121 lb FT=0% LUMBER- TOP CHORD 2x4 SP M 30*Except* NOTES- T3:2x4 SP No.2 1)Unbalanced roof live loads have been considered BOT CHORD 2x4 SP M 30*Except* for this design. B1:2x4 SP M 31 2)Wind:ASCE 7-10;Vult=165mph(3-second gust) WEBS 2x4 SP No.3 Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; WEDGE Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) Left:2x4 SP No.3 and C-C Extedor(2)zone;cantilever left and right BRACING- exposed;end vertical left exposed;C-C for members TOP CHORD and forces&MWFRS for reactions shown;Lumber Structural wood sheathing directly applied or 2-2-0 oc DOL=1.60 plate grip DOL=1.60 purlins. 3)All plates are MT20 plates unless otherwise BOT CHORD indicated. Rigid ceiling directly applied or 3-11-5 oc bracing. 4)Plates checked for a plus or minus 0 degree MiTek recommends that Stabilizers and required rotation about its center. cross bracing be installed during truss erection,in 5)This truss has been designed for a 10.0 psf bottom accordance with Stabilizer Installation ouidp. chord live load nonconcurrent with any other live loads. REACTIONS. (lb/size) 6)*This truss has been designed for a live load of 6 = 1536/0-8-0 (min.0-2-0) 20.Opsf on the bottom chord in all areas where a 1 = 1589/0-8-3 (min.0-1-8) rectangle 3-6-0 tall by 2-0-0 wide will fit between the Max Horz bottom chord and any other members. 1 = -70(LC 13) 7)Provide mechanical connection(by others)of truss Max Uplift to bearing plate capable of withstanding 100 lb uplift 6 = -613(LC 9) atjoint(s)except Gt=lb)6=613,1=560. 1 = -560(LC 8) 8)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design FORCES. (lb) of this truss. Max.Comp./Max.Ten.-All forces 250(lb)or less 9)Warning:Additional permanent and stability except when shown. bracing for truss system(not part of this component TOP CHORD design)is always required. 1-1=-1963/1374,1-2=-4717/3331, 2-3=-3993/2848,3-4=-3951/2851, 4-5=-5179/3691,5-6=-5068/3536 LOAD CASE(S) BOT CHORD Standard 1-1 5=1 332/1909,1-11=-3111/4505, 10-11=-31 11/4505,9-1 0=-3471/5065, 8-9=-3471/5065,7-8=-3318/4849, 6-7=-3328/4844 WEBS 2-10=827/615,3-10=-589/944, 4-1 0-1 363/1006,5-8=-1 57/278 -Julius Lee;PZ #34869 1.169 Coastal Bay Boynton Beach,FL 33435 1` Job I russ I cuss Type ty y �7868 58824 A03 Hip 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc, Fri Jun 20 14:35:05 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=—3SFBC—dC_hTGNW?pv3yoJZ79Pdft5dzi6hRXCz4NKZ 7-1-10 12-0-9 13-6 g8 18 10 4 21 4 0 _ 27-11-13 r 7-1-10 4 10-15 1-5-15 5-3-12 2-5-12 6-7-13 Scale:1/4"=V 1.50112 4x4= 4x6= 2.94 12 3 4 4x4= 3.00112 3x4% 5 1.5x4 2 6 cr , 05 Io 11 10 9 8 3x6= 3x8 11 1.5x4 11 3x8= 4x4= 3x8— 3x6 -10- 7-1-10 12-0-9 13-6-8 18-10-4 27-11-13 6-3-1 4 10-15 1-5-15 5-3-12 9-1-9 Plate Offsets(X,Y)— [1:0-0-4,1-9-51,[1:0-4-1,Edgel,[3:0-2-0,0-2-4],[5:0-1-12,0-2-8),[7:0-3-14,Edge) LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/de0 L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.99 Vert(LL) 0.53 8-10 >639 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.70 Vert(TL) -0.68 8-10 >495 240 BCLL 0.0 * Rep Stress Incr YES WB 0.48 Horz(TL) 0.14 7 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:120 lb FT=0% LUMBER- TOP CHORD 2x4 SP M 30*Except* NOTES- T2,T4:2x4 SP No.2 1)Unbalanced roof live loads have been considered BOT CHORD 2x4 SP M 30'Except' for this design. B1:2x4 SP M 31 2)Wind:ASCE 7-10;Vult=165mph(3-second gust) WEBS 2x4 SP No.3 Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; WEDGE Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) Left:2x4 SP No.3 and C-C Extedor(2)zone;cantilever left and right BRACING- exposed;end vertical left exposed;C-C for members TOP CHORD and forces&MWFRS for reactions shown;Lumber Structural wood sheathing directly applied. DOL=1.60 plate grip DOL=1.60 BOT CHORD 3)Provide adequate drainage to prevent water Rigid ceiling directly applied or 4-0-7 cc bracing. ponding. MiTek recommends that Stabilizers and required 4)Plate(s)at joint(s)3,5,7,2,11,10,8,6,1 and 1 cross bracing be installed during truss erection,in checked for a plus or minus 0 degree rotation about accordance with Stabilizer Installation guide. its center. 5)Plate(s)at joint(s)4 and 9 checked for a plus or REACTIONS. (lb/size) minus 4 degree rotation about its center. 7 = 1514/0-8-0 (min.0-2-0) 6)This truss has been designed for a 10.0 psf bottom 1 = 1564/0-8-3 (min.0-1-8) chord live load nonconcurrent with any other live Max Horz loads. 1 = -73(LC 13) 7)*This truss has been designed for a live load of Max Uplift 20.Opsf on the bottom chord in all areas where a 7 = -597(LC 9) rectangle 3-6-0 tall by 2-0-0 wide will fit between the 1 = -585(LC 8) bottom chord and any other members. 8)Provide mechanical connection(by others)of truss FORCES. (lb) to bearing plate capable of withstanding 100 lb uplift Max.Comp./Max.Ten.-All forces 250(lb)or less at joint(s)except Qt=lb)7=597,1=585. except when shown. 9)"Semi-rigid pitchbreaks with fixed heels"Member TOP CHORD end fixity model was used in the analysis and design 1-1=-1915/1336,1-2=-4584/3234, of this truss. 2-3=-3753/2675,3-4=-3646/2671, 10)Warning:Additional permanent and stability 4-5=-4257/3063,5-6=4328/3062, bracing for truss system(not part of this component 6-7=-4807/3435 design)is always required. BOT CHORD 1-15=1301/1867,1-11=-3010/4372, 10-11=-3010/4372,9-10=2427/3623, LOAD CASE(S) 8-9=-2427/3623,7-8=-3217/4581 Standard WEBS 2-10=886010,3-10=-368/582, 6-8=-534/531,4-10=-319/191, 4-8=-382/663 Julius Lee;P.E. #34869 1109 Coastal Bay Boynton Beach„FL 33435 Job I russ I cuss Type -- ty y 58824 A04 Roof Special 1 1 Job Reference o tional A03578fi9 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:06 2014 Page 1 I D:YRb6ZZgQrA7iabCgpBwopfz7lH_-_3SFBC_dC_hTGNW?pv3yoJZC7Pbtt8yzj6hRXCz4NKZ 7-0-1 10-6-5 13-11-6 17 4 8 20-10-12 27-8-0 7-0-1 3-6-3 3-5-1 3-5-1 3-6-5 6-9-4 Scale=1:46.5 4 4x4= x = 2.94 12 3x4= 4 3.00112 5 1.5x4 I 1.5x4 2 6 3x8 11 d N ' v1 7 v �! Lj F =1 I I II 0Lj0 10 9 8 3x6 zz 3x8— 3x8 MT20H= 3x6 3x8= 10- 10-6-5. 17-4-8 27-8-0 101 9-7-11 6-10-3 10-3-9 Plate Offsets(X,Y)— [1:0-0-8,1-9-5),[1:0-4-1,Edgel,[7:0-3-14,Edgel LOADING(psf) SPACING- 2-0-12 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.67 Vert(LL) 0.53 8-10 >624 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.81 Vert(TL) -0.70 8-13 >477 240 MT20H 1871143 BCLL 0.0 * Rep Stress Incr NO WB 0.27 Horz(TL) 0.15 7 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:116 lb FT=0% LUMBER- TOP CHORD 2x4 SP M 30*Except* NOTES- T2:2x4 SP No.2 1)Unbalanced roof live loads have been considered BOT CHORD 2x4 SP M 30*Except* for this design. B1:2x4 SP M 31 2)Wind:ASCE 7-10;Vult=165mph(3-second gust) WEBS 2x4 SP No.3 Vasd=128mph;TCDL=S.Opsf;BCDL=S.Opsf;h=20ft; WEDGE Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) Left:2x4 SP No.3 and C-C Exterior(2)zone;cantilever left and right BRACING- exposed;end vertical left exposed;C-C for members TOP CHORD and forces&MWFRS for reactions shown;Lumber 2-0-0 oc purlins(2-9-15 max.) DOL=1.60 plate grip DOL=1.60 (Switched from sheeted:Spacing>2-0-0). BOT CHORD 3)Provide adequate drainage to prevent water Rigid ceiling directly applied or 4-0-4 oc bracing. 4)All.plates ll.plates are MT20 plates unless otherwise REACTIONS. (lb/size) indicated. 7 = 1544/0-8-0 (min.0-2-0) 5)Plates checked for a plus or minus 0 degree 1 = 1595/0-8-3 (min.0-1-8) rotation about its center. Max Horz 6)This truss has been designed for a 10.0 psf bottom 1 = -66(LC 13) chord live load nonconcurrent with any other live Max Uplift loads. 7 = -620(LC 9) 7) This truss has been designed for a live load of 1 = -644(LC 8) 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the FORCES. (lb) bottom chord and any other members. Max.Comp./Max.Ten.-All forces 250(lb)or less 8)Provide mechanical connection(by others)of truss except when shown. to bearing plate capable of withstanding 100..lb uplift TOP CHORD atjoint(s)except at=lb)7=620,1=644. 1-1=-1926/1326,1-2=-4593/3268, 9)"Semi-rigid pitchbreaks with fixed heels"Member 2-3=-4013/2801,3-4=-3911/2785, end fixity model was used in the analysis and design 4-5=-3961/2817,5-6=4073/2839, of this truss. 6-7=-4814/3447 10)Graphical purlin representation does not depict BOT CHORD the size or the orientation of the purlin along the top 1-14=1304/1878,1-10=-3033/4378, and/or bottom chord. 9-10=2724/4087,8-9=2724/4087, 11)Warning:Additional permanent and stability 7-8=-3226/4588 bracing for truss system(not part of this component WEBS design)is always required. 2-10=-625/598,3-10=-325/581, 5-8=-377/643,6-8=-800/775, LOAD CASE(S) 4-10=-485/283,4-8=434/242 Standard Jullus Lee;P.E. 934,869'. 1109 Coastal Bay Boynton Beach,,FL'33435 1 Job I russ I russ I ype y y A0357870 58824 A05 Roof Special 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:07 2014 Page 1 ID:YRb6ZZgQrA7labOgp8wopfz7lH_SFOdOY?FzHpKuW5BNdaBLW6KcpwgcW96ymR?3ez4NKY 5-9 6 8 4 4 13-8-6 19-0-9 21-7-7 27-2-10 5-9-6 2-6-13 5-4-3 5-4-3 2-6-14 5-7-3 Scale=1:45.7 2.94 F12 4x4= 3x4= 4x4= 3.00 12 1.5x4 3 5 1.5x4 2 6 3x8 11 m N vi 7i Li '? IC5 10 9 8 3x6= 3x8— 5x10 MT20H WB= 3x8= 3x6 -10- 8-4-4 19-0-9 27-2-10 10- 7-5-10 10-8-6 8-2-1 Plate Offsets(X Y)— [1'0-0-12 1-9-5] [1:0-4-1 Edoe] [3:0-2-0 0-2-4] [5:0-2-0 0-2-41 [7:0-3-14,Edge] LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.88 Vert(LL) 0.63 8-10 >515 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.84 Vert(TL) -1.11 8-10 >293 240 MT20H 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.59 Horz(TL) 0.16 7 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:114 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2*Except* NOTES- TV 2x4 SP M 31 1)Unbalanced roof live loads have been considered BOT CHORD 2x4 SP M 30 for this design. WEBS 2x4 SP No.3 2)Wind:ASCE 7-10;Vult=165mph(3-second gust) WEDGE Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Left:2x4 No.3 Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) BRACING-- and C-C Exterior(2)zone;cantilever left and right TOP CHORD exposed;end vertical left exposed;C-C for members Structural wood sheathing directly applied or 2-2-0 oc and forces&MWFRS for reactions shown;Lumber purlins. DOL=1.60 plate grip DOL=1.60 BOT CHORD 3)Provide adequate drainage to prevent water Rigid ceiling directly applied or 3-11-3 oc bracing. ponding. MiTek recommends that Stabilizers and required 4)All plates are MT20 plates unless otherwise cross bracing be installed during truss erection,in indicated. accordance with Stabilizer Installation ouide. 5)Plates checked for a plus or minus 0 degree rotation about its center. REACTIONS. (lb/size) 6)This truss has been designed for a 10.0 psf bottom 7 = 1471/0-8-0 (min.0-1-14) chord live load nonconcurrent with any other live 1 = 1524/0-8-3 (min.0-1-15) loads. Max Horz 7)*This truss has been designed for a live load of 1 = -50(LC 13) 20.Opsf on the bottom chord in all areas where a Max Uplift rectangle 3-6-0 tall by 2-0-0 wide will fit between the 7 = -606(LC 9) bottom chord and any other members. 1 = -627(LC 8) 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift FORCES. (lb) atjoint(s)except(jt=lb)7=606,1=627. Max.Comp./Max.Ten.-All forces 250(lb)or less 9)"Semi-rigid pitchbreaks with fixed heels"Member except when shown. end fixity model was used in the analysis and design TOP CHORD of this truss. 1-1=-1895/1304,1-2=-4346/3021, 10)Warning:Additional permanent and stability 2-3=-4175/2837,3-4=-4102/2821, bracing for truss system(not part of this component 4-5=-4188/2876,5-6=-4274/2900, design)is always required. 6-7=-4673/3242 BOT CHORD 1-14=-1164/1701,1-10=-2807/4133, LOAD CASE(S) 9-10=-3295/4811,8-9=3295/4811, Standard 7-8=-3043/4457 WEBS 3-10=-279/537,4-10=-942/745, 4-8=-870/686,5-8=-343/628, 6-8=-408/451 Julius Lee;F.S. #34869. 1109 Coastal Bay Boynton Beach,.FL'33435 Job I russ I cuss Type City Ply A0357871 58824 A06G Roof Special Girder 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:07 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH--sFOdOY?FzHpKu W5BNdaBLW6KEpwgcRl6ymR?3ez4NKY 7-1-14 13-6-12 19-11-11 26-11-11 7-1-14 6-4-14 6-4=14 .,' 7-0-0 Scale=1:45.6 2.94 12 8x = 2x4 II 7 8= 3.00 12 3 4x8 11 v Ins 9 8 7 6 3x8= 1.5x4 11 5x8= 5x10 MT20H WB= 1.5x4 11 3x10= -10- 7-1-14 13-6-12 19-11-11 26-11-11 10- 6-3-5 6-4-14 6-4-14 7-0-0 Plate Offsets(X Y)— [1:0-0-8,1-8-131 f1:0-2-12 Edgel,[2:0-2-4 0-4-01 [4:0-2-0 0-4-01,[8:0-4-0 0-1-81 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.84 Vert(LL) 0.52 8 >621 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.83 Vert(TL) -1.10 6-8 >294 240 MT20H 187/143 BCLL 0.0 ' Rep Stress]nor NO WB 0.94 Horz(TL) 0.20 5 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:120 lb FT=0% LUMBER- TOP CHORD 2x4 SP M 31 *Except* 10)Hanger(s)or other connection device(s)shall be T2:2x6 SP 240OF 2.OE,T3:2x4 SP M 30 WEBS provided sufficient to support concentrated load(s)36 BOT CHORD 2x4 SP M 31 2-9=-33/420,2-8=-850/2458, lb down and 126 lb up at 7-1-14,and 99 lb down and WEBS 2x4 SP No.3 3-8=-813/493,4-8=-703/1994, 161 lb up at 8-6-8,and 162 lb down and 268 lb up at OTHERS 2x4 SP No.3 4-6=-71/562 19-11-10 on top chord,and 221 lb down and 143 lb WEDGE up at 7-1-14,57 lb down at 8-6-8,57 lb down at Left:2x4 SP No.3 NOTES- 10-6-8,57 lb down at 12-6-8,57 lb down at 13-10-15 BRACING- 1)Unbalanced roof live loads have been considered 57 lb down at 15-10-15,and 57 lb down at TOP CHORD for this design. 17-10-15,and 331 lb down and 176 lb up at 19-10-15 Structural wood sheathing directly applied or 2-4-0 oc 2)Wind:ASCE 7-10;Vuit=165mph(3-second gust) on bottom chord. The design/selection of such purlins. Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; connection device(s)is the responsibility of others. BOT CHORD Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope); 11)Warning:Additional permanent and stability Rigid ceiling directly applied or 5-1-12 oc bracing. cantilever left and right exposed;end vertical left bracing for truss system(not part of this component MiTek recommends that Stabilizers and required exposed;Lumber DOL=1.60 plate grip DOL=1.60 design)is always required. cross bracing be installed duringtruss erection,in 3)Provide adequate drainage to prevent water ondin 12)In the LOAD CASE(S)section,loads applied to accordance with Stabilizer Installation uide. p g• the face of the truss are noted as front(F)or back(B). 4)All plates are MT20 plates unless otherwise REACTIONS. (lb/size) indicated. 5 = 1987/0-8-omin.0-1-10 5)Plates checked for a plus or minus 0 degree ( ) LOAD CASE(S) 1 = 1989/0-8-3 (min.0-1-10) rotation about its center. Standard Max Horz 6)This truss has been designed for a 10.0 psf bottom 1)Dead+Roof Live(balanced):Lumber 1 = -43(LC 9) chord live load nonconcurrent with any other live Increase=1.25,Plate Increase=1.25 Max Uplift loads. Uniform Loads(p0) *7) This truss has been designed for a live load of 5 = -813(LC 5) Vert:1-2=-90,2-4=-90,4-5=90,10-13=-20 1 = -839(LC 4) 20.Opsf on the bottom chord in all areas where a Concentrated Loads(lb) rectangle 3-6-0 tall by 2-0-0 wide will fit between the Vert:2=-36(F)4=-105(F)7=-33(F)9=-221(F) FORCES. (lb) bottom chord and any other members. 6=-331(F)18=-99(F)19=-33(F)20=-33(F) Max.Comp./Max.Ten.-All forces 250(lb)or less 8)Provide mechanical connection(by others)of truss 21=-33(F)22=-33(F)23=-33(F) except when shown. to bearing plate capable of withstanding 100 lb uplift TOP CHORD atjoint(s)except Ot=1b)5=813,1=839. 1-1=-2367/992,1-2=-5650/2365, 9)"Semi-rigid pitchbreaks with fixed heels"Member 2-18=-7588/3034,3-18=-7594/3035, end fixity model was used in the analysis and design 3-4=-7593/3035,4-5=-6076/2453 of this truss. BOT CHORD 1-13=-945/2212,1-9=-2242/5418, 9-19=-2244/5443,19-20=-2244/5443, 20-21=-2244/5443,8-21=-2244/5443, 8-22=-2305/5858,7-22=-2305/5858, 7-23=2305/5858,6-23=-2305/5858, 5-6=-2299/5821 WEBS Julius,Lee,P.E. 934869 2-9=-33/420,2-8=-850/2458, 1109 Coastal Bay Boynton Beach,,FL 33435 u Job I russ I cuss Type ty y A0357872 58824 B01G GABLE 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,.FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc, Fri Jun 20 14:35:08 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=wSa?cuOtkbxBWgfOwK5QtkeZkDLEL?XGBQAYb5z4NKX 6-7-4 10-9-12 14-11-10 21-10-5 6-7-4 4-2-9 4-1-13 6-10-12 4x4= Scale=1:38.8 3 6.00 F12 3x8 5 \ 5.87 Ll2 2 T T 4 W3 W5 T I W4 3x10= STr T T T T T 0 1 5. 81 B2 1} 2x4 11 2x4 11 12 11 2x4 11 3x4= 2x4 11 4x6—_ 5x10= 2x4 11 2x4 11 2x4 11 2x4 11 4x8 11 4x4= 10 9 8 7 6 3x4= 6-7-4 10-7-15 10�0-12 14-11-10 20-11-15 �1-10-� 6-7 4 4-0-11 0- -14 4-1-13 6-0-5 0-10-6 Plate Offsets(X Y)— 11:0-2-0 Edgel [4:0-3-12 0-2-4] [5:0-1-1 Edge] [5:0-1-7 1-1-61,[10:0-5-0 0-2-121,[14:0-1-8,0-0-12],[23:0-1-8 0-0-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.60 Vert(LL) 0.05 12-28 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.50 Vert(TL) -0.09 12-28 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.45 Horz(TL) 0.01 30 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:155 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 10)"Semi-rigid pitchbreaks with fixed heels"Member BOT CHORD 2x6 SP No.2 TOP CHORD end fixity model was used in the analysis and design WEBS 2x4 SP No.3*Except* 1-2=-496/188,23=-109/379, of this truss. W4:2x6 SP No.2 3-33=-135/416,33-34=-86/313, 11)Hanger(s)or other connection device(s)shall be OTHERS 2x4 SP No.3 4-34=-37/294 provided sufficient to support concentrated load(s) WEDGE BOT CHORD 121 lb down and 194 lb up at 11-3-1,and 121 lb Right:2x4 SP No.3 1-12=-140/352,11-12=-137/344, down and 194 lb up at 13-3-1,and 166 lb down and BRACING- 11-36=-137/344,10-36=-137/344 319 lb up at 15-3-1 on top chord,and 265 lb down TOP CHORD WEBS and 184 lb up at 9-8-12,and 46 lb down and 102 lb Structural wood sheathing directly applied or 6-0-0 oc 10-26=-754/417,3-26=-652/367, up at 13-3-1,and 209 lb down and 443 lb up at purlins. 4-10=-388/268,4-8=-413/319, 15-3-1 on bottom chord. The design/selection of such BOT CHORD 2-10=-777/424,2-12=-62/327 connection device(s)is the responsibility of others. Rigid ceiling directly applied or 6-0-0 oc bracing, 12)Warning:Additional permanent and stability Except: NOTES- bracing for truss system(not part of this component 10-0-0 oc bracing:12-28,10-12. 1)Unbalanced roof live loads have been considered design)is always required. JOINTS for this design. 13)In the LOAD CASE(S)section,loads applied to 1 Brace at Jt(s):26 2)Wind:ASCE 7-10;Vu1t=165mph(3-second gust) the face of the truss are noted as front(F)or back(B). MiTek recommends that Stabilizers and required Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; cross bracing be installed during truss erection,in Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope); accordance with Stabilizer Installation guide. cantilever left and right exposed;end vertical left LOAD CASE(S) exposed;Lumber DOL=1.60 plate grip DOL=1.60 Standard REACTIONS.All bearings 10-4-0 except at=length) 3) Truss designed for wind loads in the plane of the 1)Dead+Roof Live(balanced):Lumber 1=0-8-0. truss only. For studs exposed to wind(normal to the Increase=1.25,Plate Increase=1.25 (lb)-Max Horz face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as Uniform Loads 1=-146(LC 6) Vert:1-3=-90,3-5=-90,1-5=-20 Max Uplift per ANSI/TPI 1. Concentrated Loads(lb) 4)All plates are 1.5x4 MT20 unless otherwise All uplift 100 lb or less at joint(s)7, Vert:8=-25(B)33=-81(B)34=-81(B)35=-74(B) indicated. 9 except 1=-176(LC 8),10=-969(LC 8), in Plates checked for a plus or minus 0 degree 36=-265(B)37=-25(B)38=184(B)39=-100(F) 8=-729(LC 4),6=-174(LC 9),5=-118(LC 40=-100(F) 9) rotation about its center. Max Grav 6)Gable studs spaced at 2-0-0 oc. All reactions 250 lb or less at joint(s) 7)This truss has been designed for a 10.0 psf bottom 7,9,5 except 1=470(LC 1), chord live load nonconcurrent with any other live 10=1807(LC 1),10=1807(LC 1),8=692(LC loads. 20),6=285(LC 1),5=283(LC 20) 8).This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a FORCES. (lb) rectangle 3-6-0 tall by 2-0-0 wide will fit between the Max.Comp./Max.Ten.-All forces 250(lb)or less bottom chord and any other members. except when shown. 9)Provide mechanical connection(by others)of truss TOP CHORD to bearing plate capable of withstanding 100 lb uplift 1-2=-496/188,2-3=-109/379, atjoint(s)7,9 except at--lb)1=176,10=969,8=729, Julius Lee,P.E. #34869 3-33=-135/416,33-34=86/313, 6=174,5=118,5=118. 1109 Coastal Bay Boynton Beach,FL'33435 oruss cuss Type ty y A0357873 58824 �,102 Roof Special 1 1 Job Reference o ticnal Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc Fri Jun 20 14:35:08 2014 Page 1 ID:YRb671gQrA7iabOgp8wopfz7lH=wSa?cu0tkbxBWgfOwK5QtkeUDDIHL:_gGBQAYb5z4NKX 5-8-14 11.M 15-10-10 20-8-15 _, 22-3-6 , 5-8-14 537 4-10-5 4-10-5 1.6-8 Scale=1:38.3 4x4= 3 6.00 12 5.87 12 1.5x4= 4x4 4 2 T 8 5 - 1.5x4 11 1. x II 1. x II 5 N F1 B3 1� e 3105k�11 1.5x4 11 2.9412 " 1.5x4 I I. 7 3x4= 3x6= 5x6= 10-7-2 20-8-15 21-5-022-3-6 10-7-2 10-1-12 0-8-1 0-10-6 Plate Offsets MY)— [1:0-1-2 0-0-71 [3:0-2-0 0-2-4] [4:0-0-4 0-2-0] [5:0-3-6 0-0-121,[8:0-1-12 0-0-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.95 Vert(LL) -0.29 7-8 >854 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.69 Vert(TL) -0.81 7-8 >308 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.57 Horz(TL) 0.27 7 n/a n/a BCDL 10.0 Code FBC201 OITP12007 (Matrix-M) Weight:121 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP M 30*Except* WEBS B3:2x4 SP No.2,F1:2x4 SP No.3 2-8 1052/1158,3-8=-935/1653, WEBS 2x4 SP No.3 4-8=-345/551,4-7=-2516/1921, BRACING- 5-7=-504/652 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc NOTES- purlins. 1)Unbalanced roof live loads have been considered BOT CHORD for this design. Rigid ceiling directly applied or 5-9-12 cc bracing. 2)Wind:ASCE 7-10;Vult=165mph(3-second gust) Except: Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; 4-9-0 cc bracing:8-15 Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) WEBS and C-C Exterior(2)zone;cantilever left and right 1 Row at midpt 4-7 exposed;end vertical left exposed;C-C for members with 2x4 SYP No.3 with 2-12d(0.131"x3.25")nails and and forces&MWFRS for reactions shown;Lumber cross brace spacing of 20-0-0 oc. DOL=1.60 plate grip DOL=1.60 3)Plates checked for a plus or minus 0 degree MiTek recommends that Stabilizers and required rotation about its center. cross bracing be installed during truss erection,in 4)This truss has been designed for a 10.0 psf bottom accordance with Stabilizer Installation nuide chord live load nonconcurrent with any other live loads. REACTIONS. (lb/size) 5)'This truss has been designed for a live load of 1 = 1131/0-8-0 (min.0-1-8) 20.Opsf on the bottom chord in all areas where a 7 = 1320/0-8-0 (min.0-1-11) rectangle 3-6-0 tall by 2-0-0 wide will fit between the Max Horz bottom chord and any other members. 1 = -148(LC 10) 6)Bearing at joint(s)1 considers parallel to grain Max Uplift value using ANSI/TPI 1 angle to grain formula. 1 -409(LC 12) Building designer should verify capacity of bearing 7 = -472(LC 13) surface. 7)Provide mechanical connection(by others)of truss FORCES. (lb) to bearing plate capable of withstanding 100 lb uplift Max.Comp./Max.Ten.-All forces 250(lb)or less at joint(s)except Gt=lb)1=409,7=472. except when shown. 8)"Semi-rigid pitchbreaks with fixed heels"Member TOP CHORD end fixity model was used in the analysis and design 1-2=-3747/2654,2-3=-2664/1671, of this truss. 3-4=-2389/1540,4-5=-308/114 9)Warning:Additional permanent and stability BOT CHORD bracing for truss system(not part of this component 1-8=-2278/3353,7-8=-1514/2340, design)is always required. 6-7=-121/287 WEBS LOAD CASE 2-8=-105211158,3-8=-935/1653, L Julius Lee;P.E. #34869 4-8=-345/551,47 Standard O=-2516/1921, 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ I cuss Type Qty ply A0357874 58824 B03 Roof Special 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:09 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_Oe8OpE1 Wv317gEaU2cfQxBdXce74QgPP4w6BXz4NKW 5-10-2 11-2-13 16-2-6 21-2-0 1 22� 5-10-2 5-4-11 4-11-10 4-11-10 1�8 Scale=1:39.0 4x4= 3 6.00 F12 5.87 12 1.5x4= 4 4x4 2 8 5x8 5 N 6 Cn B3 1$ 3.00 12 2.94112 7 3x4= 3x6% 5x6= 22-8-8 10-9-10 21-2-0 10.9-10 10-4-5 0-8-1 alas Plate Offsets(X,Y)— [1:0-1-6,0-0-71,[3:0-2-0,0-2-41,[4:0-0-4,0-2-01,[5:0-3-6,0-0-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.98 Vert(LL) -0.32 7-8 >804 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.65 Vert(TL) -0.87 7-8 >291 240 BCLL 0.0 Rep Stress Incr YES WB 0.59 Horz(TL) 0.29 7 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:102 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 NOTES- BOT CHORD 2x4 SP M 30*Except* 1)Unbalanced roof live loads have been considered B3:2x4 SP No.2 WEBS 2x4 SP No.3 for this design. BRACING- 2)Wind:ASCE 7-10;Vult=165mph(3-second gust) TOP CHORD Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Structural woad sheathing directly applied. Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) SOT CHORD and C-C Exterior(2)zone;cantilever left and right Rigid ceiling directly applied or 4-7-9 oc bracing. exposed;end vertical left exposed;C-C for members WEBS and forces&MWFRS for reactions shown;Lumber 1 Row at midpt 4-7 DOL=1.60 plate grip DOL=1.60 with 2x4 SYP No.3 with 2-12d(0.131"x3.25")nails and 3)Plates checked for a plus or minus 0 degree cross brace spacing of 20-0-0 oc. rotation about its center. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live MiTek recommends that Stabilizers and required loads. cross bracing be installed during truss erection,in 5).This truss has been designed for a live load of accordance with Stabilizer Installation quide. 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the REACTIONS. (lb/size) bottom chord and any other members. 1 = 1155/0-8-0 (min.0-1-8) 6)Bearing at joint(s)1 considers parallel to grain 7 = 1343/0-8-0 (min.0-1-12) value using ANSI/TPI 1 angle to grain formula. Max Horz Building designer should verify capacity of bearing 1 = -151(LC 10) surface. Max Uplift 7)Provide mechanical connection(by others)of truss 1 = -417(LC 12) to bearing plate capable of withstanding 100 lb uplift 7 = -480(LC 13) atjoint(s)except Qt=lb)1=417,7=480. 8)"Semi-rigid pitchbreaks with fixed heels"Member FORCES. (lb) end fixity model was used in the analysis and design Max.Comp./Max.Ten.-All forces 250(lb)or less of this truss. except when shown. 9)Warning:Additional permanent and stability TOP CHORD bracing for truss system(not part of this component 1-2=-3837/2719,2-3=-2727/1712, design)is always required. 3-4=-2449/1579,4-5=-330/121, 5-6=-255/4 BOT CHORD LOAD CASE(S) 1-8=-2335/3435,7-8=-1566/2413, Standard 6-7=-122/288 WEBS 2-8=-1080/1186,3-8=-961/1696, 4-8=-363/576,4-7=-2575/1965, 5-7=-517/669 Julius,Lee;P.E. #34869 1109 Coastal Bay Boynton BeachTL 33435 Job Fruss Iruss lype y y A0357875 58824 B04 Roof Special 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 2014:35:09 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wcpfz7lH_-Oe8OpE1 Wv3l7gEaU2cfQxBjucej4QPPP4w68Xz4NKW 5-11-6 11-5-5165-0 21-7-1 5-11-6 5-5-15 5-0-14 5-0-14 155 Scale=1:39.7 44= 3 6.00 12 5.87 12 1.5x4= 4 4x4 2 IF 5x8= 1.5x4 11 5 ti N d < e83 1� 3.00 F12 2.94112 7 3x4= 3x6% 5x6= 11�3 21-7-1 22-3a23-1-9, 11-0.3 10�14 0.8-1 0.10--6 Plate Offsets(X Y)— [1:0-1-10,0-0-71,f3:0-2-0,0-2-8] [4:0-1-12,0-04] [5:0-3-6 0-0-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.64 Vert(LL) -0.34 7-8 >759 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.68 Vert(TL) -0.94 7-8 >277 240 BCLL 0.0 Rep Stress Incr YES WB 0.61 Horz(TL) 0.29 7 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:104 lb FT=0% LUMBER- TOP CHORD 2x4 SP M 30*Except* T2:2x4 SP No.2 WEBS BOT CHORD 2x4 SP M 30*Except* 2-8=-1101/1207,3-8=-988/1740, B3:2x4 SP No.2 4-8=-381/603,4-7=-2622/2001, WEBS 2x4 SP No.3 5-7=-534/690 BRACING- TOP CHORD NOTES- Structural wood sheathing directly applied or 3-2-1 cc 1)Unbalanced roof live loads have been considered purlins. for this design. BOT CHORD 2)Wind:ASCE 7-10;Vult=165mph(3-second gust) Rigid ceiling directly applied or 4-6-11 cc bracing. Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; WEBS Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) 1 Row at midpt 4-7 and C-C Exterior(2)zone;cantilever left and right with 2x4 SYP No.3 with 2-12d(0.131"x3.25")nails and exposed;end vertical left exposed;C-C for members cross brace spacing of 20-0-0 cc. and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 MiTek recommends that Stabilizers and required 3)Plates checked for a plus or minus 0 degree cross bracing be installed during truss erection,in rotation about its center. accordance with Stabilizer Installation quide. 4)This truss has been designed for a 10.0 psf bottom chard live load nonconcurrent with any other live REACTIONS. (lb/size) loads. 1 = 1179/0-8-0 (min.0-1-8) 5)*This truss has been designed for a live load of 7 = 1365/0-8-0 (min.0-1-12) 20.Opsf on the bottom chord in all areas where a Max Horz rectangle 3-6-0 tall by 2-0-0 wide will fit between the 1 = -154(LC 10) bottom chord and any other members. Max Uplift 6)Bearing at joint(s)1 considers parallel to grain 1 = -426(LC 12) value using ANSI/TPI 1 angle to grain formula. 7 = -488(LC 13) Building designer should verify capacity of bearing surface. FORCES. (lb) 7)Provide mechanical connection(by others)of truss Max.Comp./Max.Ten.-All forces 250(lb)or less to bearing plate capable of withstanding 100 lb uplift except when shown, atjoint(s)except Qt=lb)1=426,7=488. TOP CHORD 8)"Semi-rigid pitchbreaks with fixed heels"Member 1-2=-3924/2779,2-3=-2791/1754, end fixity model was used in the analysis and design 34=-2512/1620,4-5=-369/132, of this truss. 5-6=-280/12 9)Warning:Additional permanent and stability BOT CHORD bracing for truss system(not part of this component 1-8=-2388/3514,7-8=-1624/2492, design)is always required. 6-7=-55/302 WEBS 2-8=-1101/1207,3-8=-988/1740, LOAD CASE(S) Julius.Leei P.E. 934869 4-8=-381/603,4-7=-2622/2001, Standard 1.108 Coastal Bay Boynton Beach,EL 33435 Job Truss Truss Type Qty HY A035787fi 58824 B05 Roof Special 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc Fri Jun 20 14:35:10 2014 Page 1 I D:YR b6ZZg QrA7iabOq p8wopfz7lH--sq imOZ 17 G C Bul—pm2l8uz9ktF0_aptGZekffgzz4N KV 6-0-10 11-7-13 1610-0 3-6 22-0-2 2 -10 i 6-0-10 5-7-3 5 2-3 5-2-3 1-6-8 Scale=1:40.5 4x4•= 3 6.00 F12 5.87 12 1.5x4= 4x4 4 2 8 5x8= 1,5x4 II 5 N M 1 6 M ° `63 Ig 3.00 12 2.94112 7 3x4= 3x8% 5x6= 23-frlo 11-2-11 , 22-0-2 22-8-4 , 11-2-11 10-9-8 0-8-1 0.10-6 Plate Offsets(X Y)— [1:0-0-10 Edge] r3:0-2-0,0-2-81,[4:0-1-12,0-0-4],r5:0-3-6 0-0-12] LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.66 Vert(LL) -0.37 7-8 >716 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.70 Vert(TL) -1.01 7-8 >262 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.63 Horz(TL) 0.30 7 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:106 lb FT=0% LUMBER- TOP CHORD 2x4 SP M 30*Except* T2:2x4 SP No.2 WEBS BOT CHORD 2x4 SP M 30*Except* 2-8=-1128/1235,3-8=-1014/1784, LOAD CASE(S) B3:2x4 SP No.2 4-8=-399/628,4-7=-2681/2046, Standard l WEBS 2x4 SP No.3 5-7=-547f708 BRACING- TOP CHORD NOTES- Structural wood sheathing directly applied or 3-0-15 oc 1)Unbalanced roof live loads have been considered purlins. for this design. BOT CHORD 2)Wind:ASCE 7-10;Vult=165mph(3-second gust) Rigid ceiling directly applied or 4-5-5 oc bracing. Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; WEBS Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) 1 Row at midpt 4-7 and C-C Exterior(2)zone;cantilever left and right with 2x4 SYP No.3 with 2-12d(0.131"x3.25")nails and exposed;end vertical left exposed;C-C for members cross brace spacing of 20-0-0 oc. and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 MiTek recommends that Stabilizers and required 3)Plate(s)at joint(s)1,3,6,7,2,4 and 5 checked for cross bracing be installed during truss erection,in a plus or minus 0 degree rotation about its center. accordance with Stabilizer Installation quide. 4)Plate(s)at joint(s)8 checked for a plus or minus 3 degree rotation about its center. REACTIONS. (lb/size) 5)This truss has been designed for a 10.0 psf bottom 1 = 1202/0-8-0 (min.0-1-8) chord live load nonconcurrent with any other live 7 = 138810-8-0 (min.0-1-13) loads. Max Horz 6)'This truss has been designed for a live load of 1 = -157(LC 10) 20.Opsf on the bottom chord in all areas where a Max Uplift rectangle 3-6-0 tall by 2-0-0 wide will fit between the 1 = -434 LC 12 bottom chord and any other members. 7 = -497(LC 13) 7)Bearing at joint(s)1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. FORCES. (lb) Building designer should verify capacity of bearing Max.Comp./Max.Ten.-All forces 250(lb)or less surface. except when shown. 8)Provide mechanical connection(by others)of truss TOP CHORD to bearing plate capable of withstanding 100 lb uplift 1-2=4015/2844,2-3=-2854/1795, at joint(s)except(jt=lb)1=434,7=497. 34=-2572/1659,4-5=-392/139, 9)"Semi-rigid pitchbreaks with fixed heels"Member 5-6=-297/16 end fixity model was used in the analysis and design BOT CHORD of this truss. 1-8=-2445/3596,7-8=-1676/2566, 10)Warning:Additional permanent and stability 6-7=-62/323 bracing for truss system(not part of this component WEBS design)is always required. 2-8=-1128/1235,3-8=-1014/1784, Juflus Lee;P.E. #34869 4-8=-399/628,4-7=-2681/2046, 1109 Coastal Bay Boynton Beach,FL"33435 Job russ I russ ype ty y A0357877 58824 B06 Roof Special 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Prink 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:10 2014 Page 1 ID:YRb6ZZg Q rA7iab Og p8wo pfz7lH_-sgimOZ17G C Bu I_pm218uz9ktrOz9 psrZe kffgzz4 N KV 61-14 11-10-5 17-1-12 225-3 23-11-11 , 6-1-14 5-8-7 5-3-7 5-3-7 1-6-8 Scale=1:41.2 44= 3 6.00 12 5.87 12 1.5x4= 4x4 4 2 8 5x8= 2x4 11 r 5 0 N cl 1 6 Cl) e , B3 Io ` 3.00 12 2.94112 7* ` 3x4 3x8; = 5x6= 23-11-11 11-5-3 22-5-3 23-1-5 , 11-5.3 11-0-1 0-t3-1 0-10.6 Plate Offsets(X,Y)— [1:0-0-10 Edgel,r3:0-2-0,0-2-81,[4:0-1-12,0-0-41,[5:0-3-6,0-0-81 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.69 Vert(LL) -0.40 7-8 >677 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.73 Vert(TL) -1.08 7-8 >249 240 BCLL 0.0 Rep Stress Incr YES WB 0.66 Horz(TL) 0.31 7 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight:108 lb FT=0% LUMBER- TOP CHORD 2x4 SP M 30*Except* T2:2x4 SP No.2 WEBS BOT CHORD 2x4 SP M 30*Except* 2-8=-1156/1263,3-8=-1040/1827, LOAD CASE(S) B3:2x4 SP No.2 4-8=-418/653,4-7=-2739/2090, Standard WEBS 2x4 SP No.3 5-7=-561/726 BRACING- TOP CHORD NOTES- Structural wood sheathing directly applied or 2-11-10 oc 1)Unbalanced roof live loads have been considered purlins. for this design. BOT CHORD 2)Wind:ASCE 7-10:Vu1t=165mph(3-second gust) Rigid ceiling directly applied or 4-3-13 oc bracing. Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; WEBS Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) 1 Row at midpt 4-7 and C-C Exterior(2)zone;cantilever left and right with 2x4 SYP No.3 with 2-12d(0.131"x3.25")nails and exposed;end vertical left exposed;C-C for members cross brace spacing of 20-0-0 oc. and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 MiTek recommends that Stabilizers and required 3)Plate(s)at joint(s)1,3,6,7,2,4 and 5 checked for cross bracing be installed during truss erection,in a plus or minus 0 degree rotation about its center. accordance with Stabilizer Installation guide. 4)Plate(s)at joint(s)8 checked for a plus or minus 3 degree rotation about its center. REACTIONS. (lb/size) 5)This truss has been designed for a 10.0 psf bottom 1 = 1226/0-8-0 (min.0-1-9) chord live load nonconcurrent with any other live 7 = 1411/0-8-0 (min.0-1-13) loads. Max Horz 6)*This truss has been designed for a live load of 1 = -160(LC 10) 20.0psf on the bottom chord in all areas where a Max Uplift rectangle 3-6-0 tall by 2-0-0 wide will fit between the 1 = -443 LC 12 bottom chord and any other members. 7 = -505(LC 13) 7)Bearing at joint(s)1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. FORCES. (lb) Building designer should verify capacity of bearing Max.Comp./Max.Ten.-All forces 250(lb)or less surface. except when shown. 8)Provide mechanical connection(by others)of truss TOP CHORD to bearing plate capable of withstanding 100 lb uplift 1-2=-4105/2909,2-3=-2917/1835, at joint(s)except Ot=lb)1=443,7=505. 3-4=-2632/1698,4-5=-416/149, 9)"Semi-rigid pitchbreaks with fixed heels"Member 5-6=-314/20 end fixity model was used in the analysis and design BOT CHORD of this truss. 1-8=-2502/3678,7-8=-1729/2640, 10)Warning:Additional permanent and stability 6-7=-68/345 bracing for truss system(not part of this component WEBS design)is always required. 2-8=-1156/1263,3-8=-1040/1827, Julius Lee;P.E. 934869 4-8=-418/653,4-7=-2739/2090, 1109 Coastal Bay Boynton Beacti,'FL 33435 F. t Job I russ cuss I ype y y A0357878 58824 607 Roof Special 1 1 - Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:11 2014 Page 1 , ID:YRb6ZZgQrA7iabOgp8wopfz7lH--K1 G8Ev211 WJIN80zcSf7VMGOvQILYE?itOPCCQz4NKU 632 12-0-13 175-9 22-10-5 24-4-12 632 5-9-11 5-4-12 5-4-12 1�8 Scale=1:42.0 4x4= 3 6.00 12 5.87 12 N 3x4 1.5x4= 4 2 9 5x8= 4x10 5 ob 8 N 1 5x6// 6 M 83 Io ` 3.00 FIT 2.94112 7' � 3x4 3x8 = 5x6= 24-4-12 11-7-11 17-3.0 22-10-5 23-&6 1 11-7-11 5-7-5 5-7-5 0-8-1 0-10-6 Plate Offsets(X,Y)— [1:0-0-10,Edgel,[3:0-2-0,0-2-81,[5:0-3-12,0-2-01,f7:0-1-12,0-2-81,[8:0-2-8,0-2-81 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.80 Vert(LL) -0.40 9-12 >689 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.80 Vert(TL) -1.07 9-12 >257 240 BCLL 0.0 Rep Stress Incr YES WB 0.98 Horz(TL) 0.32 7 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight:111 lb FT=0% LUMBER- TOP CHORD 2x4 SP M 30*Except* T2:2x4 SP No.2 WEBS BOT CHORD 2x4 SP No.2*Except* 2-9=-1192/1286,3-9=-1074/1855, LOAD CASE(S) B1:2x4 SP M 30 4-9=-535/591,4-8=-288/317, Standard WEBS 2x4 SP No.3 5-8=-1835/2801,5-7=-1574/1329 BRACING- TOP CHORD NOTES- Structural wood sheathing directly applied or 2-11-3 oc 1)Unbalanced roof live loads have been considered purlins. for this design. BOT CHORD 2)Wind:ASCE 7-10;Vult=165mph(3-second gust) Rigid ceiling directly applied or 2-2-0 oc bracing. Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; WEBS Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) 1 Row at micipt 5-8. and C-C Exterior(2)zone;cantilever left and right with 2x4 SYP No.3 with 2-12d(0.131"x3.25")nails and exposed;end vertical left exposed;C-C for members crass brace spacing of 20-0-0 oc. and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 MiTek recommends that Stabilizers and required 3)Plate(s)at joint(s)1,3,6,7,2,4,8 and 5 checked cross bracing be installed during truss erection,in for a plus or minus 0 degree rotation about its center. accordance with Stabilizer Installation guide. 4)Plate(s)at joint(s)9 checked for a plus or minus 3 degree rotation about its center. REACTIONS. (lb/size) 5)This truss has been designed for a 10.0 psf bottom 1 = 1247/0-8-0 (min.0-1-9) chord live load nonconcurrent with any other live 7 = 1437/0-8-0 (min.0-1-14) loads. Max Horz 6).This truss has been designed for a live load of 1 = -163(LC 10) 20.Opsf on the bottom chord in all areas where a Max Uplift rectangle 3-6-0 tall by 2-0-0 wide will fit between the 1 = -450 LC 12 bottom chord and any other members. 7 = -514(LC 13) 7)Bearing atjoint(s)1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. FORCES. (lb) Building designer should verify capacity of bearing Max.Comp./Max.Ten.-All forces 250(lb)or less surface. except when shown. 8)Provide mechanical connection(by others)of truss TOP CHORD to bearing plate capable of withstanding 100 lb uplift 1-2=-4181/2973,2-3=-2957/1878, at joint(s)except at--lb)1=450,7=514. 3-4=-2671/1741,4-5=-3157/2083, 9)"Semi-rigid pitchbreaks with fixed heels"Member 5-6=-296/177 end fixity model was used in the analysis and design BOT CHORD of this truss. 1-9=-2559/3747,8-9=-1688/2780, 10)Warning:Additional permanent and stability 6-7=-235/405 bracing for truss system(not part of this component WEBS design)is always required. 2-9=-1192/1286,3-9=-1074/1855, Julius Lee;P.E. #34869' 4-9=-535/591,4-8=-288/317, 1109 Coastal Bay Boynton Beach,'FL'33435 Job Truss I cuss Type Qty y A0357879 pl 58824 B08 Roof Special 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc Fri Jun 2014:35:11 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_K1 G8Ev211 WJIN80zcSf7VMGOfQKxYllitOPCCQz4NKU 6-4-6 12-3-6 17-9-6 23-3-6 24-9-14 , 6-4-6 5-10-15 5-6-0 5-" 1-6-8 Scale=1:42.7 44= 3 6.00 12 5.87 12 3x4 3x4 4 2 9 5x8= 3x6 5 10 8 1 1.5x4 11 5x6 zz 6 M $[ B3 Ia 3.00 12 2.94112 7`* ` 4x4� 5x6= 3x4= 24-9-14 6.1-13 11-10-3 17-6-13 , 23-3-6 23.117 , r.1-13 5-" 5.8.9 5-8-9 0-8-1 0-10-6 Plate Offsets(X,Y)— [1:0-1-10,Edoe),[3:0-2-0,0-2-81 [7:0-1-12 0-2-81 LOADING(pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.81 Vert(LL) 0.38 9-10 >741 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.69 Vert(TL) -0.54 9-10 >513 240 BCLL 0.0 Rep Stress[nor YES WB 0.71 Horz(TL) 0.34 7 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix-M) Weight:115 lb FT=0% LUMBER- TOP CHORD 2x4 SP M 30*Except* T2:2x4 SP No.2 WEBS BOT CHORD 2x4 SP N0.2*Except* 2-9=-1224/1171,3-9=-1150/1905, LOAD CASE(S) B1:2x4 SP-M 30 4-9=-570/604,4-8=-283/333, Standard WEBS 2x4 SP No.3*Except* 5-8=-1873/2898,5-7=-1606/1346 W6:2x4 SP No.2 BRACING- NOTES- TOP CHORD 1)Unbalanced roof live loads have been considered Structural wood sheathing directly applied or 2-9-9 oc for this design. purlins. 2)Wind:ASCE 7-10;Vult=165mph(3-second gust) BOT CHORD Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Rigid ceiling directly applied or 4-4-9 oc bracing. Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) WEBS and C-C Exterior(2)zone;cantilever left and right 1 Row at midpt 5-8 exposed;end vertical left exposed;C-C for members with 2x4 SYP No.3 with 2-12d(0.131"x3.25")nails and and forces&MWFRS for reactions shown;Lumber cross brace spacing of 20-0-0 oc. DOL=1.60 plate grip DOL=1.60 3)Plate(s)atjoint(s)1,3,6,7,2,10,4,8 and 5 MiTek recommends that Stabilizers and required checked for a plus or minus 0 degree rotation about cross bracing be installed during truss erection,in its center. accordance with Stabilizer Installation quide. 4)Plate(s)at joint(s)9 checked for a plus or minus 3 degree rotation about its center. REACTIONS. (lb/size) 5)This truss has been designed for a 10.0 psf bottom 1 = 1270/0-8-0 (min.0-1-9) chord live load nonconcurrent with any other live 7 = 1460/0-8-0 (min.0-1-14) loads. Max Horz 6)*This truss has been designed for a live load of 1 = 165(LC 10) 20.Opsf on the bottom chord in all areas where a Max Uplift rectangle 3-6-0 tall by 2-0-0 wide will fit between the 1 = -459(LC 12) bottom chord and any other members. 7 = -522(LC 13) 7)Bearing atjoint(s)1 considers parallel to grain value using ANSI/fPI 1 angle to grain formula. FORCES. (lb) Building designer should verify capacity of bearing Max.Comp./Max.Ten.-All forces 250(lb)or less surface. except when shown. 8)Provide mechanical connection(by others)of truss TOP CHORD to bearing plate capable of withstanding 100 lb uplift 1-2=-4277/2889,2-3=-3002/1950, atjoint(s)except Qt=lb)1=459,7=522. 3-4=-2718/1792,4-5=-3242/2139, 9)"Semi-rigid pitchbreaks with fixed heels"Member 5-6=-331/169 end fixity model was used in the analysis and design BOT CHORD of this truss. 1-1 O=2471/3798,9-10=-2477/3813, 10)Warning:Additional permanent and stability 8-9=-1741/2856,6-7=-222/455 bracing for truss system(not part of this component WEBS design)is always required. Julius Lee;F.E. #34869 2-9=-1224/1171,3-9=-1150/1905, 1109 Coastal Bay Boynton Beach,.FL 33435 1 > R Job russ cuss Type y y 58824 809 Roof Special 1 1 Job Reference(optional) A0357880 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:11 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_K1 G8Ev211 WJIN80zcSf7VMG?FQJeYlbitOPCCQz4NKU 65-10 125-14 18-1-2 23.8-7 25-2-15 , 6-5-10 6-0-3 5-7-5 5-7-5 1.6.8 ' Scale=1:43.4 4x4= 3 6.00 12 5.87 12 3x4 3x4 4 2 9 5x8= 3x6 5 10 8 N 1 1.5x4 11 5x6 zz� 6 rY� 3 Id ` 3.00 12 2.94112 7e `r 5x6= 3x4= 3x6= 25-2-15 fs3-1 12-0-11 17-10-9 23-8.7 24-4-9 1 fi3.1 5-9-10 5-9.14 5.9-14 8.1 0-164 Plate Offsets(X,Y)— [3:0-2-0,0-2-8),[7:0-1-12,0-2-8) LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/de0 L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.84 Vert(LL) 0.39 9-10 >723 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.71 Vert(TL) -0.57 9-10 >500 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.75 Horz(TL) 0.35 7 n/a n/a BCOL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:117 lb FT=0% LUMBER- TOP CHORD 2x4 SP M 30*Except' T2:2x4 SP No.2 WEBS BOT CHORD 2x4 SP No.2*Except* 2-9=-1254/1198,3-9=-1176/1947, LOAD CASE(S) 131:2x4 SP M 30 4-9=-592/627,4-8=-282/334, Standard WEBS 2x4 SP No.3*Except* 5-8=-1912/2962,5-7=-1637/1372 W6:2x4 SP No.2 BRACING- NOTES- TOP CHORD 1)Unbalanced roof live loads have been considered Structural wood sheathing directly applied or 2-7-14 oc for this design. purlins. 2)Wind:ASCE 7-10;Vult=165mph(3-second gust) BOT CHORD Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Rigid ceiling directly applied or 4-3-13 oc bracing. Cat.II;Exp,D;Encl.,GCpi=0.18;MWFRS(envelope) WEBS and C-C Exterior(2)zone;cantilever left and right 1 Row at midpt 5-8 exposed;end vertical left exposed;C-C for members with 2x4 SYP No.3 with 2-12d(0.131"x3.25")nails and and forces&MWFRS for reactions shown;Lumber crass brace spacing of 20-0-0 oc. DOL=1.60 plate grip DOL=1.60 3)Plate(s)at joint(s)1,3,6,7,2,10,4,8 and 5 MiTek recommends that Stabilizers and required checked for a plus or minus 0 degree rotation about cross bracing be installed during truss erection,in its center. accordance with Stabilizer Installation guide. 4)Plate(s)at joint(s)9 checked for a plus or minus 3 degree rotation about its center. REACTIONS. (lb/size) 5)This truss has been designed for a 10.0 psf bottom 1 = 1293/0-8-0 (min.0-1-10) chord live load nonconcurrent with any other live 7 = 1483/0-8-0 (min.0-1-15) loads. Max Horz 6)*This truss has been designed for a live load of 1 = -168(LC 10) 20.Opsf on the bottom chord in all areas where a Max Uplift rectangle 3-6-0 tall by 2-0-0 wide will fit between the 1 = -467(LC 12) bottom chord and any other members. 7 = -530(LC 13) 7)Bearing at joint(s)1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. FORCES. (lb) Building designer should verify capacity of bearing Max.Comp./Max.Ten.-All forces 250(lb)or less surface. except when shown. 8)Provide mechanical connection(by others)of truss TOP CHORD to bearing plate capable of withstanding 100 lb uplift 1-2=-4370/2952,2-3=-3064/1990, at joint(s)except Qt=lb)1=467,7=530. 34=-2777/1831,4-5=-3327/2197, 9)"Semi-rigid pitchbreaks with fixed heels"Member 5-6=-335/173 end fixity model was used in the analysis and design BOT CHORD of this truss. 1-10=2527/3882,9-10=-2533/3897, 10)Warning:Additional permanent and stability 8-9=-1791/2933,6-7=-227/460 bracing for truss system(not part of this component WEBS design)is always required. Julius Lee;P.E. #30169 2-9=-1254/1198,3-9=-1176/1947, 1109 Coastal Bay Boynton Beach,FL 33435 1 o russ cuss ype Qy y . ' t A0357881 58824 CA Comer Jack 3 j:1; Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946.. Run:7.520 s May 8 2014 Print 7.520 a May 8 2014 Mi rek Industries,Inc. Fri Jun 2014:35:12 2014 Page 1 ID:YRb6ZZgQrA7iabO4pSwopfz71H_pDgWRF3NogRa Iz99AAM2apNfgpoHwcr529mksz4NKT 0-11-11 Scale=1:6.4 6.00 12 i i 1 T1 d 0 � d B1 3 2x4= 0-10-14 0-10-14 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.03 Vert(LL) 0.00 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.08 Vert(TL) 0.00 4 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC20101TP12007 (Matrix-M) Weight:3 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 6)Provide mechanical connection(by others)of truss BRACING- to bearing plate capable of withstanding 100 lb uplift TOP CHORD atjoint(s)2,4. StStructural wood sheathing directly applied or 0-11-11 oc 7)Non Standard bearing condition. Review required. St r 8) 'Semi-rigid pitchbreaks with fixed heels"Member BOT CHORD end fixity model was used in the analysis and design of this truss. Rigid ceiling directly applied or 6-0-0 oc bracing. 9)Warning:Additional permanent and stability MiTek recommends that Stabilizers and required bracing for truss system(not part of this component cross bracing be installed.during truss erection,in design)is always required. accordance with Stabilizer Installation guide. REACTIONS. (lb/size) LOAD CASE(S) 2 = 73/Mechanical Standard 4 = 35/Mechanical Max Horz 2 = 89(LC 1) 4 = -89(LC 1) Max Uplift 2 = -32(LC 12) 4 = -16(LC 8) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=S.Opsf;BCDL=S.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. J61ius Lee,P.E. 934869: 5)Refer to girder(s)for truss to truss connections. 1109 Coastal Bay Boynton Beach,'FL'33435 r x Y A Job I russ inuss I ype Qty y A0357882 58824 CJ1A Comer Jack 1 1 - Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc Fri Jun 20 14:35:12 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_pDgWRF3NcgRc_lz99AAM2apNxgggHwcr529mksz4NKT r 0-11-11 Scale=1:6.4 6.00 12 r r 11 XI o 1 T1 g d � d B1 Qo Qo Qo Al 2x4= 0-11-11 , 0-11-11 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.01 Vert(LL) -0.00 6 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(TL) -0.00 4 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:3 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 6)Provide mechanical connection(by others)of truss BOT CHORD 2x4 SP No.2 to bearing plate capable of withstanding 100 lb uplift BRACING- at joint(s)3,2. TOP CHORD 7)"Semi-rigid pitchbreaks with fixed heels"Member Structural wood sheathing directly applied or 0-11-11 oc end fixity model was used in the analysis and design purT of this truss. ROT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. 8)Warning:Additional permanent and stabilitybracing for truss system(not part of this component MiTek recommends that Stabilizers and required design)is always required. cross bracing be installed during truss erection,in accordance with Stabilizer Installation quide. LOAD CASE(S) REACTIONS.All bearings 0-11-11 except Qt=length) Standard 2=Mechanical. (lb)-Max Harz 1= 32(LC 12) Max Uplift All uplift 100 lb or less at joint(s)3, 2 Max Grav All reactions 250 lb or less at joint(s) 1,3,2,1 FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)'This.truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the Julius Lee;P.E. #34B69 bottom chord and any other members. 1:109 Coastal Bay 5)Refer to girder(s)for truss to truss connections. Boynton Beach,FL'334M Job I russ I russ Type Qty ply A0357883 58824 CAB Comer Jack 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:12 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz71H--pDgWRF3NogRc Iz99AAM2apMygplHwcr529mksz4NKT 1-5-11 1-5-11 3.00 F12 Scale=1:5.7 i i 1 0 i B1 3x4= 2x4 II 1-4-0 1-4-0 0-1-11 Plate Offsets(X Y)— [1:0-0-15 0-7-10] [1:0-1-4 Edoel LOADING(psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.07 Vert(LL) 0.00 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.08 Vert(TL) -0.00 4 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 1 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:5 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4)'This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 1-5-11 oc 5)Refer to girder(s)for truss to truss connections. purlins. 6)Provide mechanical connection(by others)of truss BOT CHORD to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 10-0-0 oc bracing. atjoint(s)3,2 except(jt=lb)1=160. MiTek recommends that Stabilizers and required 7)"Semi-rigid pitchbreaks with fixed heels"Member cross bracing be installed during truss erection,in end fixity model was used in the analysis and design accordance with Stabilizer Installation guide. of this truss. 8)Warning:Additional permanent and stability REACTIONS. (lb/size) bracing for truss system(not part of this component 1 = 200/0-5-8 (min.0-1-8) design)is always required. 3 = -25/Mechanical 2 = -14/Mechanical Max Harz LOAD CASE(S) 1 = 24(LC 8) Standard Max Uplift 1 = -160(LC 8) 3 = -25(LC 1) 2 = -14(LC 1) Max Grav 1 = 200(LC 1) 3 = 14(LC 8) 2 = 1O(LC 8) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=o.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60-plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. Julius Lee;P.E. #34869: 3)This truss has been designed for a 10.0 psf bottom 1109 Coastal Bay chord live load nonconcurrent with any other live loads. Boynton Beach,FL 33435 Job I russ I cuss ype Qty ply A0357884 58824 CJ1C Comer Jack 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:13 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=HPNufb40Z7ZTcRYLjthbanMYQEAoONs7KiuJHlz4NKS 1-5-11 1-5-11 3.00 Fl2 Scale=1:5.7 i 1 T1 i 1 / o Qo Qo . Qo Qo 2x4 1-5-11 1-5-11 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft . Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.03 Vert(LL) -0.00 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.03 Vert(fL) -0.00 4 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:5 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 6)Provide mechanical connection(by others)of truss BOT CHORD 2x4 SP No.2 to bearing plate capable of withstanding 100 lb uplift BRACING- atjoint(s)1,3,2. TOP CHORD 7)"Semi-rigid pitchbreaks with fixed heels"Member Structural wood sheathing directly applied or 1-5-11 oc end fixity model was used in the analysis and design BOT CHORD purT of this truss. 8)Warning:Additional permanent and stability Rigid ceiling directly applied or 10-0-0 oc bracing. bracing for truss system(not part of this component MiTek recommends that Stabilizers and required design)is always required. cross bracing be installed during truss erection,in accordance with Stabilizer Installation quide. LOAD CASE(S) REACTIONS. (lb/size) Standard 1 = 83/0-8-0 (min.0-1-8) 3 = 38/Mechanical 2 = 40/Mechanical Max Horz 1 = 24(LC 8) Max Uplift 1 = -31(LC 8) 3 = -17(LC 8) 2 = -20(LC 8) FORCES. (lb). Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=S.Opsf;BCDL=S.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the Julius Lee;P.E. 934869 bottom chord and any other members. 1109 Coastal Bay 5)Refer to girder(s)for truss to truss connections. Boynton Beach,FL 33435 I Job I Russ Truss Fype Qty my A0357885 58824 CJ2 Comer Jack 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:13 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_HPNufb4OZ7ZTcRYLjthbanMY?E9PONs?KiuJHlz4NKS 1-2-9 1-2-9 3.00 12 Scale=1:5.4 i 1 � \ � m T1 r4 d � m B1 2x4 1-2-9 i 1-1-1 10-13 1-1-1 -0.12 0.0.12 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.06 Vert(LL) 0.00 6 n/r 120 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.12 Vert(TL) -0.00 6 n/r 120 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC201 OITP12007 (Matrix-M) Weight:4 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4)'This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 1-2-9 oc 5)Refer to girder(s)for truss to truss connections. purlins. 6)Provide mechanical connection(by others)of truss BOT CHORD to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 6-0-0 oc bracing. at joint(s)3,2. MiTek recommends that Stabilizers and required 7)Non Standard bearing condition. Review required. cross bracing be installed during truss erection,in 8)"Semi-rigid pitchbreaks with fixed heels"Member accordance with Stabilizer Installation quide. end fixity model was used in the analysis and design of this truss. REACTIONS. (lb/size) 9)Warning:Additional permanent and stability 3 = 54/Mechanical bracing for truss system(not part of this component 2 = 83/Mechanical design)is always required. Max Horz 3 = -232(LC 1) 2 = 232(LC 1) LOAD CASE(S) Max Uplift Standard 3 = -44(LC 8) 2 = -72(LC 8) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-547/253 BOT CHORD 1-3=-252/558 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=S.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Julius,Lee;P.E. #34869 1109 Coastal Bay Boynton Beach,FL"33435 Job Truss I rues Type y y A0357886 58824 CJ2A Comer Jack 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:13 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_HPNufb4OZ7ZTcRYLjthbanMXbEBbONs7KiuJHlz4NKS 1-6-1 1-6-1 2.94 F12 Scale=1:5.7 r i 1 d T1 ay d B1 a 2x4= 1-4-8 1-4-8 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/de0 Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.08 Vert(LL) 0.00 6 n/r 120 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.17 Vert(TL) -0.00 6 n/r 120 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix-M) Weight:5 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4)'This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 1-6-1 oc 5)Refer to girder(s)for truss to truss connections. purlins. 6)Provide mechanical connection(by others)of truss BOT CHORD to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 6-0-0 oc bracing. at joint(s)3,2. MiTek recommends that Stabilizers and required 7)Non Standard bearing condition. Review required. cross bracing be installed during truss erection,in 8)"Semi-rigid pitchbreaks with fixed heels"Member accordance with Stabilizer Installation guide. end fixity model was used in the analysis and design of this truss. REACTIONS. (lb/size) 9)Warning:Additional permanent and stability 3 = 49/Mechanical bracing for truss system(not part of this component 2 = 115/Mechanical design)is always required. Max Horz 3 = -288(LC 1) 2 = 288(LC 1) LOAD-CASES) Max Uplift Standard 3 = -44(LC 8) 2 = -94(LC 8) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-682/317 BOT CHORD 1-3=-312/691 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Julius Lee;P.E. #34869 1109 Coastal Bay Boynton Beach,.FL 33435 Job I russ I cuss I ype Qty y 7887 58824 CJ3 Comer Jack 3 1 Job Reference(optional) A035 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:14 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=IcxHsx4eKRhKEb7XHbCg7?uizdT2lg68ZMetpkz4NKR 2-11-11 2-11-11 Scale=1:11.1 6.00 12 T1 d 1 W1 Li B1 2x4= Q, 3x8 11 -8 2-11-11 00-10-101 2-1-3 Plate Offsets(X,Y)— [1:0-14 Edgel,[1:0-0-8,1-0-51 LOADING(psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.10 Vert(LL) -0.00 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.16 Vert(TL) -0.01 4 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:12 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 3)This truss has been designed for a 10.0 psf bottom BOT CHORD 2x4 SP No.2 chord live load nonconcurrent with any other live WEDGE loads. Left:2x6 SP No.2 4)'This truss has been designed for a live load of BRACING- 20.Opsf on the bottom chord in all areas where a TOP CHORD rectangle 3-6-0 tall by 2-0-0 wide will fit between the Structural wood sheathing directly applied or 2-11-11 oc bottom chord and any other members. pudins. 5)Refer to girder(s)for truss to truss connections. BOT CHORD 6)Provide mechanical connection(by others)of truss Rigid ceiling directly applied or 10-0-0 oc bracing. to bearing plate capable of withstanding 100 lb uplift MiTek recommends that Stabilizers and required at jcint(s)2,3,1. cross bracing be installed during truss erection,in 7)"Semi-rigid pitchbreaks with fixed heels"Member accordance with Stabilizer Installation quide. end fixity model was used in the analysis and design of this truss. REACTIONS. (lb/size) 8)Warning:Additional permanent and stability 2 = 65/Mechanical bracing for truss system(not part of this component 3 = -5/Mechanical design)is always required. 1 = 261/0-8-0 (min.0-1-8) Max Harz 1 = 98(LC 12) LOAD CASE(S) Max Uplift Standard 2 = -63(LC 12) 3 = -5(LC 1) 1 = -80(LC 12) Max Grav 2 = 65(LC 1) 3 = 18(LC 3) 1 = 261(LC 1) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 Julius Lee;P.E. 934869. 2)Plates checked for a plus or minus 0 degree rotation 1109 Coastal Bay about its center. Boynton B6ach,'EL 33435 Job I russ russ Type y y A0357888 58824 CJ3A Comer Jack 1 1 Job Reference o tional Al ROOF TRUSSES,FORT PIERCE,FL 34946 _ Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:14 2014 Page 1 ID:YRb6ZZgQrA7iabOgpBwopfz7lH=IcxHsx4eKRhKEb7XHbCg7?uh2dTRlg68ZMetpkz4NKR 2-11-11 2-11-11 Scale=1:11.1 6.00 F12 0 T1 1 B1 0° 2x4= 2-11-11 2-11-11 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.16 Vert(LL) 0.01 3-6 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.13 Vert(TL) -0.01 3-6 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:10 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 2)Plates checked for a plus or minus 0 degree BOT CHORD 2x4 SP No.2 rotation about its center. BRACING- 3)This truss has been designed for a 10.0 psf bottom TOP CHORD chord live load nonconcurrent with any other live Structural wood sheathing directly applied or 2-11-11 oc loads. BOT CHORD purT 4)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a Rigid ceiling directly applied or 10-0-0 oc bracing. rectangle 3-6-0 tall by 2-0-0 wide will fit between the MiTek recommends that Stabilizers and required bottom chord and any other members. cross bracing be installed during truss erection,in 5)Refer to girder(s)for truss to truss connections. accordance with Stabilizer Installation guide. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift REACTIONS. (lb/size) atjoint(s)1,2,3. 1 = 185/0-8-0 (min.0-1-8) 7)"Semi-rigid pitchbreaks with fixed heels"Member 2 = 99/Mechanical end fixity model was used in the analysis and design 3 = 37/Mechanical of this truss. Max Horz 8)Warning:Additional permanent and stability 1 = 98(LC 12) bracing for truss system(not part of this component Max Uplift design)is always required. 1 = -57(LC 12) 2 = -78(LC 12) 3 = -3(LC 12) LOAD CASE(S) Max Grav Standard 1 = 185(LC 1) 2 = 99(LC 1) 3 = 48(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-292/289 BOT CHORD 1-3=-530/419 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=S.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber Julius Lee;P.E. 934869 DOL=1.60 plate grip DOL=1.60 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ cuss I ype y y A0357889 58824 CAB Comer Jack 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:14 2014 Pa 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=IcxHsx4eKRhKEb7XHbCg7?uhHdTSlg68ZMetpkz4NIZR 3-5-11 3-5-11 Scale:1.5'=V 3.00 12 � o T1 r 1 �n '- d d B1 3x4= 2x4 II >< 0-10-8 3-5-11 0-10 8 2-7-3 Plate Offsets(X Y)— [1:0-0-15,0-7-101 rl:0-1-4,Edgel LOADING(pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.15 Vert(LL) -0.00 7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.13 Vert(TL) -0.00 3-7 >999 240 BCLL 0.0 ' Rep Stress]nor YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight:11 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4)*This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.0psf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 3-5-11 oc 5)Refer to girder(s)for truss to truss connections. purlins. 6)Provide mechanical connection(by others)of truss BOT CHORD to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 10-0-0 oc bracing. at joint(s)2 except Qt=lb)1=109. MiTek recommends that Stabilizers and required 7)"Semi-rigid pitchbreaks with fixed heels"Member cross bracing be installed during truss erection,in end fixity model was used in the analysis and design accordance with Stabilizer Installation guide. of this truss. 8)Warning:Additional permanent and stability REACTIONS. (lb/size) bracing for truss system(not part of this component 1 = 275/0-5-8 (min.0-1-8) design)is always required. 2 = 87/Mechanical 3 = 14/Mechanical Max Horz LOAD CASE(S) 1 = 57(LC 8) Standard Max Uplift 1 = -109(LC 8) 2 = -61(LC 8) Max Grav 1 = 275(LC 1) 2 = 87(LC 1) 3 = 35(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=o.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom Julius Lee;P.E. #34869 chord live load nonconcurrent with any other live loads. 1109 Coastal Bay Boynton Beackfl-"33435 Job I russ cuss Type ty y 58824 CJ3C Comer Jack 1 1 Job Reference o tional A0357890 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 M7ek Industries,Ina Fri Jun 20 14:35:15 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_DoVf4H5G51pBdikrlj3gCRsm1 pvUHLIoONQLBz4NKQ 3-5-11 3-5-11 Scale:1.5'=V 3.00 F12 T1 c�5 1 u� d d B1 0° Q° 2x4 Zz 3-5-11 3-5-11 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.17 Vert(LL) 0.02 3-6 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.18 Vert(TL) -0.02 3-6 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 1 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:11 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 2)Plates checked for a plus or minus 0 degree BOT CHORD 2x4 SP No.2 rotation about its center. BRACING- 3)This truss has been designed for a 10.0 psf bottom TOP CHORD chord live load nonconcurrent with any other live Structural wood sheathing directly applied or 3-5-11 oc loads. pT BOT CHORD 4).This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a Rigid ceiling directly applied or 10-0-0 oc bracing. rectangle 3-6-0 tall by 2-0-0 wide will fit between the MiTek recommends that Stabilizers and required bottom chord and any other members. cross bracing be installed during truss erection,in 5)Refer to girder(s)for truss to truss connections. accordance with Stabilizer Installation guide. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift REACTIONS. (lb/size) atjoint(s)1,2,3. 1 = 210/0-8-0 (min.0-1-8) 7)"Semi-rigid pitchbreaks with fixed heels"Member 2 = 113/Mechanical end fixity model was used in the analysis and design 3 = 52/Mechanical of this truss. Max Horz 8)Warning:Additional permanent and stability 1 = 57(LC 8) bracing for truss system(not part of this component Max Uplift design)is always required. 1 = -82(LC 8) 2 = -71(LC 8) 3 = -7(LC 8) LOAD CASE(S) Max Grav Standard 1 = 210(LC 1) 2 = 113(LC 1) 3 = 57(LC 3) FORCES..(lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-390/361 BOT CHORD 1-3=-435/415 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat,11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber Julius Lee;P.E. #34866 DOL=1.60 plate grip DOL=1.60 1109 Coastal Bay Boynton Beach,FL 33M Job Truss I russ I ype Qty ply A0357891 58824 CJ4 Comer Jack 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc Fri Jun 20 14:35:15 2014 Pagge� 1 ID:YRb6ZZgQrA7iabCgp8wopfz7lH_-DoVf4H5G5lpBrlikrlj3gCRshl pTUHLIoONQLBz4NKQ 3-8-2 3-8-2 Scale=1:8.3 3.00 F12 v T1 N 1 � Bi 3x4= 2x4 II >< 0-10-8 3-8-2 0-10-8 2-9-10 Plate Offsets(X,Y)— (1:0-0-15 0-7-10] 11:0-1-4 Edge] LOADING(pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.17 Vert(LL) -0.00 3-7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.14 Vert(TL) -0.00 3-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:11lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4)'This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom cho?d in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural woad sheathing directly applied or 3-8-2 cc 5)Refer to girder(s)for truss to truss connections. ROT CHORD purT 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 10-0-0 cc bracing. at joint(s)2 except(jt=lb)1=114. MiTek recommends that Stabilizers and required 7)"Semi-rigid pitchbreaks with fixed heels"Member cross bracing be installed during truss erection,in end fixity model was used in the analysis and design accordance with Stabilizer Installation quide. of this truss. 8)Warning:Additional permanent and stability REACTIONS. (lb/size) bracing for truss system(not part of this component 1 = 286/0-5-8 (min.0-1-8) design)is always required. 2 = 95/Mechanical 3 = 17/Mechanical Max Horz LOAD CASE(S) 1 = 61(LC 8) Standard Max Uplift 1 = -114(LC 8) 2 = -66(LC 8) Max Grav 1 = 286(LC 1) 2 = 95(LC 1) 3 = 39(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom Julius Lee;P.E. #34869 chord live load nonconcurrent with any other live loads. 1109 Coastal Bay Boynton Beach,FL'33435 Job I russ cuss Type Uty ply A0357892 58824 CJ4A Comer Jack 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 2014:35:15 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopf771H--DoVf4H5G5IpBdikrlj3gCRsn1 pBUHLIoONQLBz4NKQ 3-6-9 3-6-9 Scale:1.5'=V 2.94 12 d. T1 c� 1 n d d i B1 X 3x4= 2x4 II Q' A* 0' 0-10-9 3-6-9 0-10-9 2-8-0 Plate Offsets(X,Y)— [1:0-0-15,0-7-81,[1:0-1-8,Edge) LOADING(psif) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.16 Vert(LL) -0.00 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.16 Vert(TL) -0.00 4 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:11 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4)*This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 3-6-9 oc 5)Refer to girder(s)for truss to truss connections. pudins. 6)Provide mechanical connection(by others)of truss BOT CHORD to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 10-0-0 oc bracing. at joint(s)2 except at--lb)1=115. MiTek recommends that Stabilizers and required 7)"Semi-rigid pitchbreaks with fixed heels"Member cross bracing be installed during truss erection,in end fixity model was used in the analysis and design accordance with Stabilizer Installation Quide. of this truss. 8)Warning:Additional permanent and stability REACTIONS. (lb/size) bracing for truss system(not part of this component 1 = 288/0-8-3 (min.0-1-8) design)is always required. 2 = 87/Mechanical 3 = 8/Mechanical Max Harz LOAD CASE(S) 1 = 57(LC 8) Standard Max Uplift 1 = -115(LC 8) 2 = -62(LC 8) Max Grav 1 = 288(LC 1) 2 = 87(LC 1) 3 = 32(LC 3) FORCES. (lb) Max.Camp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;End.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom Julius Lee;P.E. #34869 chord live load nonconcurrent with any other live loads. 1109 Coastal Bay Boynton Beach,.FL 33435 Job I russ I cuss Type y y Job Reference(optional) A0357893 58824 CJ5 Comer Jack 1 1 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 2014:35:16 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=h_31 Hd6ur2y2TvHwOOEICQ_y1 R7YDjbROg7zudz4NKP 5-5-11 5-5-11 Scale=1:10.9 3.00 12 Ti m � c9 1 B1 3x4= 0-10-8 5-5-11 0.10.8 4-7-3 Plate Offsets(X Y)— [1:0-5-8 0-0-81 LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Well Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.45 Vert(LL) -0.02 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.28 Vert(TL) -0.03 3-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:17 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 2)Plates checked for a plus or minus 0 degree BOT CHORD 2x4 SP No.2 rotation about its center. BRACING- 3)This truss has been designed for a 10.0 psf bottom TOP CHORD chord live load nonconcurrent with any other live Structural wood sheathing directly applied or 5-5-11 cc loads. purlins. 4).This truss has been designed for a live load of BOT CHORD 20.Opsf on the bottom chord in all areas where a Rigid ceiling directly applied or 10-0-0 cc bracing. rectangle 3-6-0 tall by 2-0-0 wide will fit between the MiTek recommends that Stabilizers and required bottom chord and any other members. cross bracing be installed during truss erection,in 5)Refer to girder(s)for truss to truss connections. accordance with Stabilizer Installation uide. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift REACTIONS. (lb/size) atjoint(s)except at=lb)1=158,2=110. 1 = 394/0-5-8 (min.0-1-8) 7)"Semi-rigid pitchbreaks with fixed heels"Member 2 = 1621Mechanical end fixity model was used in the analysis and design 3 = 39/Mechanical of this truss. Max Holz 8)Warning:Additional permanent and stability 1 = 91(LC 8) bracing for truss system(not part of this component Max Uplift design)is always required. 1 = -158(LC 8) 2 = -110(LC 8) Max Grav LOAD CASE(S) 1 = 394(LC 1) Standard 2 = 162(LC 1) 3 = 72(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-223/261 BOT CHORD 1-7=-317/267 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=S.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl_GCpi=O.18;MWFRS(envelope) and C-C Extedor(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber Jullus Lee;P.E. 934869 DOL=1.60 plate grip DOL=1.60 1109 Coastal Bay Boynton Beach,FL 33435 Job Inuss russ Type ty y A0357894 58824 CJ5C Comer Jack 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Pdnt:7.520 s May 8 2014 MiTek Industries,Ina Fri Jun 2014:35:16 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_-h_31 Hd6ur2y2TvHwOOEICQyMR61 DjbROg7zudz4NKP 5-5-11 5-5-11 Scale=1:10.8 3.00 12 T1 1 B1 Q, 2x4 II �5-5-11-5-11 5-5-11 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.50 Vert(LL) 0.09 3-6 >691 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.38 Vert(TL) -0.09 3-6 >707 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 1 n/a n/a BCDL 10.0 Code FBC201 OrrPI2007 (Matrix-M) Weight:17 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 3)This truss has been designed for a 10.0 psf bottom BOT CHORD,2x4 SP N0.2 chord live load nonconcurrent with any other live BRACING- loads. TOP CHORD 4)`This truss has been designed for a live load of Structural wood sheathing directly applied or 5-5-11 cc 20.Opsf on the bottom chord in all areas where a purlins. rectangle 3-6-0 tall by 2-0-0 wide will fit between the BOT CHORD bottom chord and any other members. Rigid ceiling directly applied or 10-0-0 oc bracing. 5)Refer to girder(s)for truss to truss connections. MiTek recommends that Stabilizers and required 6)Provide mechanical connection(by others)of truss cross bracing be installed during truss erection,in to bearing plate capable of withstanding 100 lb uplift accordance with Stabilizer Installation guide. atjoint(s)except Qt=lb)1=138,2=116. 7)"Semi-rigid pitchbreaks with fixed heels"Member REACTIONS. (lb/size) end fixity model was used in the analysis and design 1 = 348/0-8-0 (min.0-1-8) of this truss. 2 = 181/Mechanical 8)Warning:Additional permanent and stability 3 = 66/Mechanical bracing for truss system(not part of this component Max Horz design)is always required. 1 = 91(LC 8) Max Uplift 1 = -138(LC 8) LOAD CASE(S) 2 = -116(LC 8) Standard Max Grav 1 = 348(LC 1) 2 = 181(LC 1) 3 = 87(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-1070/1010 BOT CHORD 1-3=-1182/1165 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.ll;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 Julius Lee;P.E. #34869: 2)Plates checked for a plus or minus 0 degree rotation 1109 Coastal Bay about its center. Boynton Beach,.FL S3435 ! f f Job I russ I cuss Type tyPly A0357895 58824 CA Comer Jack 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:16 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_h_31Hd6ur2y2TvHwOOEICQ wiR6kDjbROg7zudz4NKP 6-1-12 6-1-12 Scale:1"=1' 3.00 F12 u-, T1 1 Ell 4x4= 0-10 8 6-1-12 0-10-8 5-3-4 Plate Offsets(X Y)— fl:0-5-8,0-0-01 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.60 Vert(LL) -0.03 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.33 Vert(TL) -0.06 3-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 2 n/a n/a BCDL 10.0 Cade FBC201 O/TPI2007 (Matrix-M) Weight:19 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 2)Plates checked for a plus or minus 0 degree BOT CHORD 2x4 SP No.2 rotation about its center. BRACING- 3)This truss has been designed for a 10.0 psf bottom TOP CHORD chord live load nonconcurrent with any other live Structural wood sheathing directly applied or 6-0-0 oc loads. purlins. 4)•This truss has been designed for a live load of BOT CHORD 20.Opsf on the bottom chord in all areas where a Rigid ceiling directly applied or 10-0-0 oc bracing. rectangle 3-6-0 tall by 2-0-0 wide will fit between the MiTek recommends that Stabilizers and required bottom chord and any other members: cross bracing be installed during truss erection,in 5)Refer to girder(s)for truss to truss connections. accordance with Stabilizer Installation guide. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift REACTIONS. (lb/size) atjoint(s)except Qt=lb)1=175,2=126. 1 = 437/0-5-8 (min.0-1-8) 7)"Semi-rigid pitchbreaks with fixed heels"Member 2 = 186/Mechanical end fixity model was used in the analysis and design 3 = 46/Mechanical of this truss. Max Horz 8)Warning:Additional permanent and stability 1 = 102(LC 8) bracing for truss system(not part of this component Max Uplift design)is always required. 1 = -175(LC 8) 2 = -126(LC 8) Max Grav LOAD CASE(S) 1 = 437(LC 1) Standard 2 = 186(LC 1) 3 = 83(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-367/403 BOT CHORD 1-7=-483/433 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber Julius.Lee;P.E. #34869' DOL=1.60 plate grip DOL=1.60 1109 Coastal Bay Boynton Beach,'FL 33435 Job I russ FrUSS Type Qty Ply A0357896 58824 CJ6A Comer Jack 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 2014:35:17 2014 Page� 1 ID:YRb6ZZgQrA7iabOgpBwopfz7lH--9AdPVz7WcM4v53r6yjmXld W7KrSuyAraFKsXQ3z4NKO 5-7-2 5-7-2 Scale=1:11.0 2.94 F12 T1 m Y 1 B1 3x4= 0 10-9 5-7-2 0-10-9 4-8-9 Plate Offsets(X,Y)— f1:0-5-10,0-0-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.48 Vert(LL) -0.02 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.34 Vert(TL) -0.03 3-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 2 n/a n/a BCDL 10.0 Code FBC2010fTPI2007 (Matrix-M) Weight:17 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 3)This truss has been designed for a 10.0 psf bottom BOA CHORD 2x4 SP No.2 BRACING- chord live load nonconcurrent with any other live loads. TOP CHORD 4) This truss has been designed for a live load of Structural wood sheathing directly applied or 5-7-2 cc 20.Opsf on the bottom chord in all areas where a purT rectangle 3-6-0 tall by 2-0-0 wide will fit between the ROT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. bottom chord and any other members.5)Refer to girder(s)for truss to truss connections. MiTek recommends that Stabilizers and required 6)Provide mechanical connection(by others)of truss cross bracing be installed during truss erection,in to bearing plate capable of withstanding 100 lb uplift accordance with Stabilizer Installation guide. at joint(s)except at=lb)1=164,2=112. 7)"Semi-rigid pitchbreaks with fixed heels"Member REACTIONS. (lb/size) end fixity model was used in the analysis and design 1 = 407/0-8-3 (min.0-1-8) of this truss. 2 = 164/Mechanical 8)Warning:Additional permanent and stability 3 = 37/Mechanical bracing for truss system(not part of this component Max Horz design)is always required. 1 = 91(LC 8) Max Uplift 1 = -164(LC 8) LOAD CASE(S) 2 = -112(LC 8) Standard Max Grav 1 = 407(LC 1) 2 = 164(LC 1) 3 = 71(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. BOT CHORD 1-7=-279/225 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=S.Opsf;BCDL=S.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation Julius Lee;P.E. #34869 about its center. 1:109 Coastal Bay Boynton Beach,FL 33435 o russ fuss ype y y A0357897 58824 D01G Hip Girder 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:17 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH-9AdPVz7WcM4v53r6yjmXIdW5VrRiy9SaFKsXQ3z4NKO 5-6-8 5.0.0 b3-4 10.6-8 5-0-0. 3 5-0-0 0.3-4 Scale=1:19.0 4x4= 6.00 12 T1 W7 T1 3 1 B 1 [� 0 6 4 Q. 4 c d 3x4 1.5x4 11 = 3x4= 4x10 11 5-6-8 5-0-0 (r3-4 9-6-0 _ 10-Fr8 5-0-0 3 4-1-8 0-10-8 0-3-4 Plate Offsets(X Y)— [3:0-1-4 0-0-2] [3:0-04,Edgel LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in ([cc) I/dell Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.60 Vert(LL) 0.04 4-7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.41 Vert(TL) -0.08 4-7 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.09 Horz(TL) 0.01 3 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight:39 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4)This truss has been designed for a 10.0 psf bottom BOT CHORD 2x4 SP No.2 chord live load nonconcurrent with any other live WEBS 2x4 SP No.3 loads. WEDGE 5).This truss has been designed for a live load of Right:2x6 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 5-7-12 cc 6)Provide mechanical connection(by others)of truss purlins. to bearing plate capable of withstanding 100 lb uplift BOT CHORD at joint(s)except at=lb)1=312,3=329. Rigid ceiling directly applied or 10-0-0 cc bracing. 7)"Semi-rigid pitchbreaks with fixed heels"Member MiTek recommends that Stabilizers and required end fixity model was used in the analysis and design cross bracing be installed during truss erection,in of this truss. accordance with Stabilizer Installation guide. 8)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s) REACTIONS. (lb/size) 225 lb down and 477 lb up at 5-3-4 on top chord,and 1 = 629/0-8-0 (min.0-1-8) 40 lb down and 14 lb up at 5-0-0,and 40 lb down and 3 = 710/0-8-0 (min.0-1-8) 14 lb up at 5-5-12 on bottom chord. The Max Horz design/selection of such connection device(s)is the 1 = 69(LC 5) responsibility of others. Max Uplift 9)Warning:Additional permanent and stability 1 = -312(LC 8) bracing for truss system(not part of this component 3 = -329(LC 9) design)is always required. 10)In the LOAD CASE(S)section,loads applied to FORCES. (lb) the face of the truss are noted as front(F)or back(B). Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD LOAD CASE(S) 1-2=-1010/567,2-3=-747/398 Standard BOT CHORD 1)Dead+Roof Live(balanced):Lumber 1-4=-820/1326,3-4=-305/571, Increase=1.25,Plate Increase=1.25 3-11=-461/327 Uniform Loads(pll) NOTES- Vert:1-2=-90,2-3=90,5-8=-20 Concentrated Loads(lb) 1)Unbalanced roof live loads have been considered for Vert:4=-51(B)2=-129(B) this design. 2)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope); cantilever left and right exposed;end vertical left exposed;Lumber DOL=1.60 plate grip DOL=1.60 Julius Lee;P.E. #34869 3)Plates checked for a plus or minus 0 degree rotation 1109 Coastal Bay about its center. Boynton Be1ach,'FL'33435 o russ russ Type ty y 58824 D02 Cammon 2 1 Job Reference(optional) A0357898 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:17 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=9AdPVz7WcM4v53r6yjmXIdW6 rTfy9gaFKsXQ3z4NKO 5-3-4 10-6-8 5-3-4 5-3-4 Scale=1:19.0 4x4= 2 6.00 F12 T1 T1 W1 1 W2 3 B1 Ii 0 0 6• 4 e• o' 1.5x4 11 6 6 3x4= 3x4= 4x8 I I 5-3-4 9-8-0 1 10-6-8 , 5-3-4 4-4-12 0-10-8 Plate O_ffsets_(X,Y)-- r1:0-1-0,0-0-41,[3:0-0-12,0-0-41,[3:0-0-12,0-11-131 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.57 Vert(LL) 0.05 4-7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.29 Vert(TL) -0.06 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.07 Horz(TL) 0.01 3 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:39 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 3)Plates checked for a plus or minus 0 degree BOT CHORD 2x4 SP No.2 rotation about its center. WEBS 2x4 SP No.3 4)This truss has been designed for a 10.0 psf bottom WEDGE Right:2x6 SP No.2 chord live load nonconcurrent with any other live BRACING- loads. TOP CHORD 5)"This truss has been designed for a live load of Structural wood sheathing directly applied or 5 4-11 cc 20.Opsf on the bottom chord in all areas where arectangle 3-6-0 tall by 2-0-0 wide will fit between the ROT CHORD purT bottom chord and any other members. 6)Provide mechanical connection(by others)of truss Rigid ceiling directly applied or 10-0-0 cc bracing. to bearing plate capable of withstanding 100 lb uplift MiTek recommends that Stabilizers and required atjoint(s)except at=lb)1=206,3=227. cross bracing be installed during truss erection,in 7)"Semi-rigid pitchbreaks with fixed heels"Member accordance with Stabilizer Installation guide. end fixity model was used in the analysis and design of this truss. REACTIONS. (lb/size) 8)Waming:Additional permanent and stability 1 = 545/0-8-0 (min.0-1-8) bracing for truss system(not part of this component 3 = 61410-8-0 (min.0-1-8) design)is always required. Max Horz 1 = 71(LC 9) Max Uplift LOAD CASE(S) 1 = -206(LC 12) Standard 3 = 227(LC 13) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-1110/1007,2-3=-627/452 BOT CHORD 1-4=-1439/1504,3-4=-179/417, 3-11=256/16 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Extedor(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members Jul[us Lee;P.E. 934869. and forces&MWFRS for reactions shown;Lumber 1109 Coastal Bay DOL=1.60 plate grip DOL=1.60 Boynton Beach,FL 33435 o russ cuss ype y y A0357699 58824 D03 Common 2 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:18 2014 Page 1 ID:YRb6ZZgQrA7iabOgpBwopfz7lH-dNBnil88NgCmiDQJWQHmHr3GIFpQhcvkU—c 4yWz4NKN 5-3-4 9-8-0 5-34 44-12 Scale=1:19.1 4x4= 2 6.00 F12 T2 T1 3 3x4 W1 4 HW d B1 LJ e' 5 o' 1.5x4 11 3x4= 3x6 11 5-34 9-8-0 5-34 44-12 Plate Offsets(X Y)— [1:0-1-0 0-0-4] LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.60 Vert(LL) 0.04 5-8 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.32 Vert(TL) -0.05 5-8 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.08 Horz(TL) 0.01 4 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:37 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 3)Plates checked for a plus or minus 0 degree BOT CHORD 2x4 SP No.2 rotation about its center. WEBS 2x4 SP No.3 4)This truss has been designed for a 10.0 psf bottom SLIDER chord live load nonconcurrent with any other live BRACING- loads. TOP CHORD 5) This truss has been designed for a live load of Structural wood sheathing directly applied or 5-6-12 oc 20.Opsf on the bottom chord in all areas where a pudins. rectangle 3-6-0 tall by 2-0-0 wide will fit between the BOT CHORD bottom chord and any other members. Rigid ceiling directly applied or 9-6-8 oc bracing. 6)Refer to girder(s)for truss to truss connections. MiTek recommends that Stabilizers and required 7)Provide mechanical connection(by others)of truss cross bracing be installed during truss erection,in to bearing plate capable of withstanding 100 lb uplift accordance with Stabilizer Installation auide. at joint(s)except at=lb)1=210,4=176. 8)"Semi-rigid pitchbreaks with fixed heels"Member REACTIONS. (lb/size) end fixity model was used in the analysis and design 1 = 559/0-8-0 (min.0-1-8) of this truss. 4 = 504/Mechanical 9)Warning:Additional permanent and stability Max Horz bracing for truss system(not part of this component 1 = 83(LC 12) design)is always required. Max Uplift 1 = -210(LC 12) 4 = -176(LC 13) LOAD CASE(S) Standard FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-1048/970,2-3=-618/552, 34=-273770 BOT CHORD 1-5=-1408/1417,4-5=-355/505 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=S.Opsf;BCDL=S.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber Jullus,Lee;P.E. #34869. DOL=1.60 plate grip DOL=1.60 1109 Coastal Bay Boynton Beach,FL 33435 o russ cuss Type ty y A0357900 58824 D03D Common Girder 1 2 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:18 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_dNBnil88NgCmiDQJWQHmHr3DHFrAhdskU_o4yWz4NKN 5-3-4 9-8-0 _ 5-3-4 4-4-12 Scale=1:19.7 4x4= 2 6.00 12 3 3x4 T2 T1 W1 4 HW2 1 cy B1 d 2x4= 1.5x4 11 3x6 11 5 5-3-4 9-8-0 5-3-4 4-4-12 Plate Offsets MY)— [1:0-1-4,Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.79 Vert(LL) -0.01 1-5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.14 Vert(TL) -0.03 1-5 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.02 Horz(TL) -0.00 4 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix) Weight:76 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 2)All loads are considered equally applied to all plies, BOT CHORD 2x4 SP N0.2 except if noted as front(F)or back(B)face in the WEBS 2x4 SP No.3 LOAD CASE(S)section.Ply to ply connections have SLIDER been provided to distribute only loads noted as(F)or BRACING- (B),unless otherwise indicated. TOP CHORD 3)Unbalanced roof live loads have been considered Structural wood sheathing directly applied or 6-0-0 oc for this design. purlins. 4)Wind:ASCE 7-10;Vult=165mph(3-second gust) BOT CHORD Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Rigid ceiling directly applied or 6-0-0 cc bracing. Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) REACTIONS.All bearings 9-8-0. and C-C Exterior(2)zone;cantilever left and right , x Horz exposed;end vertical left exposed;C-C for members (lb)-Ma 1= Hor(LC 36) and forces&MWFRS for reactions shown;Lumber Max Uplift DOL=1.60 plate grip DOL=1.60 All uplift 100 lb or less at joint(s) 5)Plates checked for a plus or minus 0 degree rotation about its center. except 1=-514(LC 39),4=-567(LC 40) Max Grav 6)This truss has been designed fora 10.0 psf bottom All reactions 250 lb or less at joint(s) chord live load nonconcurrent with any other live loads. except 1=460(LC 50),4=466(LC 35), 4=430(LC 1),5=285(LC 53) 7)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a FORCES. (lb) rectangle 3-6-0 tall by 2-0-0 wide will fit between the Max.Comp./Max.Ten.-All forces 250(lb)or less bottom chord and any other members. except when shown. 8)Provide mechanical connection(by others)of truss TOP CHORD to bearing plate capable of withstanding 514 lb uplift 1-2=-979/1242,2-3=-555/911, at joint 1 and 567 lb uplift at joint 4. 3-4=-885/1175 9)This truss has been designed for a total drag load BOT CHORD of 101 plf.Lumber DOL=(1.33)Plate grip DOL=(1.33) 1-5=-948f788,4-5=-814/653 Connect truss to resist drag loads along bottom chord from 0-0-0 to 9-8-0 for 101.0 plf. OS- 10)"Semi-rigid pitchbreaks with fixed heels"Member NOTES- truss to be connected together with 12d end fixity model was used in the analysis and design of this truss. (0.131"x3.25")nails as follows: Top chords connected as follows:2x4-1 row at 0-9-0 bra 11)blaming:Additional permanent and stability oc clinched. bracing for truss system(not part of this component Bottom chords connected as follows:2x4-1 row at design)is always required. 0-9-0 oc clinched. Webs connected as follows:2x4-1 row at 0-9-0 oc LOAD CASE(S) clinched. Standard Julius Lee;P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job Truss Truss Type y y A0357901 58824 F01 ROOF TRUSS 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 Mi rek Industries,Inc Fri Jun 20 14:35:19 2014 Page 1 I D:YRb6ZZgQ rA7iabOgp8wopfz71H--6ZIAve8m8zKd KM?V48o?g2ca N e D IQ31tieLeUyz4N KM 0-3-8 0-9-11 0-10-8 0 6 6 1 4x4\\ 3x6 11 3x6 11 4x4// Scale=1: .2 2 5 3 T1 4 T1 0 1 c 81 8 7 6 3x3= 3x3= 9 0-3-8 , 1-2-0 2-2-0 3-0-7 3-6-13 0-3-8 0-10-7 1-0-0 0-10-7 026-6 Plate Offsets(X,Y)— [2:0-0-12,Edge],[4:0-3-0,Edge],[5:0-1-14,Edgel LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.06 Vert(LL) -0.00 9 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.06 Vert(TL) -0.01 9 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.07 Horz(TL) 0.00 5 n/a n/a BCDL 10.0 Code FBC2010ITP12007 (Matrix) Weight:21 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) 8)"Semi-rigid pitchbreaks with fixed heels"Member BOT CHORD 2x4 SP No.2(flat) end fixity model was used in the analysis and design WEBS 2x4 SP No.3(flat) of this truss. BRACING- 9)Gap between inside of top chord bearing and first TOP CHORD diagonal or vertical web shall not exceed 0.500in. Structural wood sheathing directly applied or 3-6-13 oc purlins. 10)Warning:Additional permanent and stability BOT CHORD bracing for truss system(not part of this component Rigid ceiling directly applied or 10-0-0 cc bracing, design)is always required. REACTIONS. (lb/size) LOAD CASE(S) 1 = 128/0-2-10 (min.0-1-8) Standard 5 = 131/0-5-14 (min.0-1-8) Max Uplift 1 = -63(LC 8) 5 = -64(LC 8) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=S.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;End.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;porch left and right exposed;C-C for members and forces&MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)Provide adequate drainage to prevent water ponding. 3)Plates checked for a plus or minus 0 degree rotation about its center. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)•This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Provide mechanical connection(by others)of truss to bearing plate at joint(s)1. 7)Provide mechanical connection(by others)of truss to Jul!u5iLee,P.E. #34869. bearing plate capable of withstanding 63 lb uplift at joint 1109 Coastal Bay 1 and 64 lb uplift at joint 5. Boynton Beagh,.FL 33436 Job russ Truss I ype y y A0357902 58824 F02 ROOF TRUSS 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Pdnt:7.520 s May 8 2014 Mrrek Industries,Inc Fri Jun 20 14:35:19 2014 Page 1 ID:YRb6ZZgQrA7iabOgpBwopfz71H -6zlAve8m8zKdKM?V48o?g2cYUeBxQ2CtieLeUyz4NKM 0-3-8 1-5-0 1-8-4 0-6-6-6 ScalA=1:11.2 3x4� 3x3 11 3x3 11 3x4,i 1 2 5 13 T2 T1 T3 0 o`t 1 B1 8 7 6 3x3= 9 3x3= 0-3-8 3-7-12 5-0-12 5-7-2 5-7-3 3 4 4 1-5-0 0-6-6 0- -1 Plate Offsets(X,Y)— [2:Edge,0-2-4] [S:Edge 0-2-4] LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.18 Vert(LL) -0.05 6 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.00 BC 0.17 Vert(TL) -0.08 9 >721 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.14 Horz(TL) 0.00 5 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:29 lb FT=O%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) 5)`This truss has been designed for a live load of BOT CHORD 2x4 SP No.2(flat) 20.Opsf on the bottom chord in all areas where a WEBS 2x4 SP No.3(flat) rectangle 3-6-0 tall by 2-0-0 wide will fit between the BRACING- bottom chord and any other members. TOP CHORD 6)Provide mechanical connection(by others)of truss Structural wood sheathing directly applied or 5-7-2 cc to bearing plate at joint(s)1. purlins. 7)Provide mechanical connection(by others)of truss BOT CHORD to bearing plate capable of withstanding 107 lb uplift Rigid ceiling directly applied or 10-0-0 cc bracing. at joint 1 and 109 lb uplift at joint 5. REACTIONS. (lb/size) 8)"Semi-rigid pitchbreaks with fixed heels"Member 1 = 216/0-2-10 (min.0-1-8) end fixity model was used in the analysis and design 5 = 219/0-5-14 (min.0-1-8) of this truss. Max Uplift 9)Gap between inside of top chord bearing and first 1 = 107(LC 8) diagonal or vertical web shall not exceed 0.500in. 5 = 109(LC 8) 10)Warning:Additional permanent and stability bracing for truss system(not part of this component FORCES. (lb) design)is always required. Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. LOAD CASE(S) TOP CHORD Standard 2-3=-228/324,3-4=-228/329, 4-5=-229/325 BOT CHORD 7-8=-323/228 WEBS 5-7=-408/288,2-8=408/288 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=S.Opsf;BCDL=S.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;porch left and right exposed;C-C for members and forces&MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)Provide adequate drainage to prevent water ponding. 3)Plates checked for a plus or minus 0 degree rotation about its center. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Jullus Lee;P.E. #34B69 1109 Coastal Bay Boynton Beach,.FL"33435 a } Job Truss Fruss Type Qty y A0357903 58824 F03 ROOF TRUSS 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc Fri Jun 20 14:35:19 2014 Page 1 ID:YRb6ZZgQrA7iabCgp8wopfz71H--6ZIAve8m8zKdKM?V48o?g2cYfeAoQ1 TtieLeUyz4NKM 0-3-8 1-5-0 , 1-10-5 0-10-11 F4 0-6-6 Scale=1:15.1 3x4 3x3 11 3x6 11 5x8= 1 3x3= 2 4 7 0 o 12 11 13 3x6= 3x3= 9 3x6= 0-3-8 1-8-8 6-2-10 , 6-8-5 7-1-2, 7-7-8 , 0-3-8 1-5-0 4-6-1 0-5-12 0 4-13 0-6-6 Plate Offsets(X Y)— f2:Edge,0-2-41 17:0-3-4,Edge1 LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.17 Vert(LL) -0.17 13 >431 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.25 Vert(TL) -0.17 13 >422 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.25 Horz(TL) 0.00 7 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:45 lb FT=0%F,O%E LUMBER- TOP CHORD 2x4 SP No.2(flat) NOTES- BOT CHORD 2x4 SP M 30(flat) 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) WEBS 2x4 SP No.3(flat) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; BRACING- Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) TOP CHORD and C-C Exterior(2)zone;cantilever left and right Structural wood sheathing directly applied or 6-0-0 cc exposed;end vertical left exposed;porch left pT exposed;C-C for members and forces&MWFRS for ROOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 REACTIONS.All bearings 1-6-7 except Qt=length) 2)Provide adequate drainage to prevent water 1=0-2-10,7=0-5-14,10=0-3-8. 3)Plates es checked for a plus or minus 0 degree (lb)-Max Uplift Plat All uplift 100 lb or less at joint(s)8, rotation about its center. 1l except 0 lb or less 8),7=t(s)8,C 1), 4)This truss has been designed for a 10.0 psf bottom 10 ex (LC 8) chord live load nonconcurrent with any other live loads. Max Grav All reactions 250 lb or less at joint(s) 5)'This truss has been designed fora live load of 8,10 except 1=264(LC 1),7=250(LC 8), rectangle f on the bottom chard i all areas where a 9=579(LC 1) rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. FORCES. (lb) 6)Provide mechanical connection(by others)of truss Max.Comp./Max.Ten.-All forces 250(lb)or less to bearing plate at joint(s)1. except when shown. 7)Provide mechanical connection(by others)of truss TOP CHORD to bearing plate capable of withstanding 100 lb uplift 2-3=-311/495,3-4=-312/501, at joint(s)8,10 except Qt=lb)1=153,7=329,9=477. 4-5=-145/431 8)"Semi-rigid pitchbreaks with fixed heels"Member BOT CHORD end fixity model was used in the analysis and design 11-12=-582/336,10-11=-400/136, of this truss. 9-10=-400/136 9)Gap between inside of top chord bearing and first WEBS diagonal or vertical web shall not exceed 0.500in. 7-9=-294/580,2-12=-627/394, 10)Warning:Additional permanent and stability 5-11=-509/138,5-9=-323/834 bracing for truss system(not part of this component design)is always required. LOAD CASE(S) Standard Jullus,Lee;P.E. #34869. 1109 Coastal Bay Boynton Beach,FL 33435 I L � 1 � Job Truss I russ Typi ty y A0357904 58824 F04 ROOF TRUSS 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:20 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_aIIY7 9PvHSUyWandrJENG8i92Up9Wvlxl5B1 Oz4NKL 0-3-8 1-5-0 2-6-0 0-5-15, 2-6-0 0 6 6 kale=1:18.8 3x4 3x6= 3x3 11 3x3— 3x3 11 3x4 ii 1 2 4 5 7 oy 9 1 11 9 8 12 3x3= 3x6= 10 3x6= p-3-$ 4-6-14 9-1-7 9-7-13, -3- 4-3-6 4-6-9 0 6-6 Plate Offsets(X,Y)— [2:Edge 0-2-4],[5:0-1-4,Edge] [7:Edge,0-2-4],[10:0-1-12,Edge] LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 1 TC 0.25 Vert(LL) -0.09 12 >613 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 i BC 0.26 Vert(TL) -0.10 12 >512 240 BCLL 0.0 Rep Stress Incr YES WB 0.11 Horz(TL) -0.00 7 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:54 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) 6)Provide mechanical connection(by others)of truss BOT CHORD 2x4 SP No.2(flat) to bearing plate atjoint(s)1. WEBS 2x4 SP No.3(flat) 7)Provide mechanical connection(by others)of truss BRACING- to bearing plate capable of withstanding 100 lb uplift TOP CHORD atjoint(s)1,7 except at=lb)10=231. Structural wood sheathing directly applied or 6-0-0 cc purlins. 8)"Semi-rigid pitchbreaks with fixed heels"Member BOT CHORD end fixity model was used in the analysis and design of this truss. Rigid ceiling directly applied or 10-0-0 oc bracing. 9)Gap between inside of top chord bearing and first REACTIONS. (lb/size) diagonal or vertical web shall not exceed 0.500in. = 159/0-2-10 (min.0-1-8) 10)Warning:Additional permanent and stability 1 1 = 159/0-5-1 (min.0-1-8) bracing for truss system(not part of this component 10 = 45411-6-7 (min.0-1-8) design)is always required. Max Uplift 1 = 80(LC 8) LOAD CASE(S) 7 = -62(LC 12) Standard 10 = -231(LC 8) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. WEBS 2-11=-275/222,3-10=-276/329 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;End.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;porch left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Provide adequate drainage to prevent water ponding. 3)Plates checked for a plus or minus 0 degree rotation about its center. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)*This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the Julius Lee;P.E. #34869 bottom chord and any other members. 9:109 Coastal Bay Boynton Beach,FL'33435 Job I russ russ Fype ty y A0357905 58824 F05 �"OOFTRUSS 1 1 Job Reference(optional) At ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:20 2014 Page 1 ID:YRb6ZZgQrA7iabOgpBwopfz7lH-a11Y7 9PvHSUyWandrJENGBhh2TR9TL1xl5B10z4NKL 0-3-8 1-5-0 0 5-15 2-6-0 1-9-5 2-6-0 0-6 6 Sca e=1:2 .0 3x4,� 3x6= 3x3 11 3x4—_ 3x3 11 3x4 1 2 1. 4 5 6 3x4= 8 0 o 15 12 11 10 9 1.5x4 11 1.5x4 11 3x6= 14 13 30= 3x6= p-3-$ 1-8-8 2- 11 5-7 11-1-12 , -8-21 3- 1_ _0 0-8-15 8-8-5 Plate Offsets(X,Y)— [2:Edge,0-2-41,[5:0-1-8,Edgel,[6:0-1-8,Edgel,[8:Edge,0-2-41,[13:0-1-4,Edgel LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.28 Vert(LL) 0.05 10-11 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.35 Vert(TL) -0.07 10-11 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.27 Horz(TL) -0.01 8 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:64 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) 3)Plates checked for a plus or minus 0 degree BOT CHORD 2x4 SP No.2(flat) rotation about its center. WEBS 2x4 SP No.3(flat) 4)This truss has been designed for a 10.0 psf bottom BRACING- chord live load nonconcurrent with any other live TOP CHORD loads. Structural wood sheathing directly applied or 6-0-0 cc 5)"This truss has been designed for a live load of purlins. 20.Opsf on the bottom chord in all areas where a BOT CHORD rectangle 3-6-0 tall by 2-0-0 wide will fit between the Rigid ceiling directly applied or 10-0-0 cc bracing. bottom chord and any other members. REACTIONS.All bearings 1-6-7 except(jt=length) 6)Provide mechanical connection(by others)of truss 1=0-2-10,8=0-5-14. to bearing plate at joint(s)1. (lb)-Max Uplift 7)Provide mechanical connection(by others)of truss All uplift 100 lb or less at joint(s)1, to bearing plate capable of withstanding 100 lb uplift 14 except 8=-140(LC 8),13=-111(LC 8) at joint(s)1,14 except Qt=Ib)8=140,13=111. Max Grav 8)"Semi-rigid pitchbreaks with fixed heels"Member All reactions 250 lb or less at joint(s) end fixity model was used in the analysis and design 1,14 except 8=388(LC 1),13=283(LC 1) of this truss. 9)Gap between inside of top chord bearing and first FORCES. (lb) diagonal or vertical web shall not exceed 0.500in. Max.Comp./Max.Ten.-All forces 250(lb)or less 10)Warning:Additional permanent and stability except when shown. bracing for truss system(not part of this component TOP CHORD design)is always required. 5-6=-721/529,6-7=467/337, 7-8=467/333 LOAD CASE(S) BOT CHORD Standard 12-13=-524/720,11-12=-524/720, 10-11=-5241720 WEBS 8-10=420/590,6-10=-280/211, 5-13=669/483 NOTES- 1)Wind:ASCE 7-10:Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) - and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;porch left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 Julius Lee;P.E. 934869 2)Provide adequate drainage to prevent water ponding. 1109 Coastal Bay Boynton Beach,FL 33435 I a 1 A / Job I russ Fruss rype Qty Ply A0357906 58824 F06 Floor 1 1 I Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:21 2014 Pa gge 1 ID:YRb67ZgQrA7iabOgp8wopfz7lH_-2yswKKA1 gbaKZg9uBZgTvThi_SkDuvjAAygkZgz4NKK 0-3-8 --14-1 0-9-4—I 1-5-2 2-6-0 2-0-0 10-0 i 1-6-0 � 0 6-6 S.e=1: 3.4 3x4\\ 3x6 11 3x6 11 3x4= 1.5x4 11 3x4= 3x3= 3x3 11 3x4,i 1 2 3 4 5 6 7 8 9 10 0 � Y 16 15 14 13 12 11 3x6= 3x3= 3x6= 1.5x4 11 1.5x4 11 3x6= 13-8-8 8-6-2 9 6-2 10� 2 11-9 1 13-2-1 13-8-7 8-2-10 1-0-0 1-0-0 1-0 0 1S-0 0- 0-0-1 Plate Offsets(X Y)— [2:0-2-5 Edgel [7:0-1-8,Edge] [10:Edge,0-2-41 LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.95 Vert(LL) -0.16 14-15 >947 480 MT20 2441190 TCDL 15.0 Lumber Increase 1.00 1 BC 0.70 Vert(TL) -0.30 14-15 >501 360 BCLL 0.0 Rep Stress Incr YES WB 0.33 Horz(TL) 0.03 10 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:75 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) 4)"Semi-rigid pitchbreaks with fixed heels"Member BOT CHORD 2x4 SP M 30(flat) end fixity model was used in the analysis and design WEBS 2x4 SP No.3(flat) of this truss. BRACING- 5)Recommend 2x6 strongbacks,on edge,spaced at TOP CHORD 10-0-0 oc and fastened to each truss with 3-10d Structural wood sheathing directly applied or 2-2-0 oc (0.131"X 3")nails. Strongbacks to be attached to purlins. walls at their outer ends or restrained by other means. BOT CHORD 6)Gap between inside of top chord bearing and first Rigid ceiling directly applied or 10-0-0 oc bracing. diagonal or vertical web shall not exceed 0.500in. REACTIONS. (lb/size) 18 = -132/1-1-4 (min.0-1-8) LOAD CASE(S) 10 = 527/0-5-14 (min.0-1-8) Standard 17 = 742/1-1-4 (min.0-1-8) Max Uplift 18 = -136(LC 7) Max Grav 10 = 529(LC 4) 17 = 742(LC 1) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 4-5=-352/0,5-6=-1363/0,6-7=-1363/0, 7-8=-1129/0,8-9=546/0,9-10=-549/0 BOT CHORD 1 16-17=0/331,15-16=0/821,14-15=0/1129, 13-14=0/1 129,12-13=0/1129 WEBS 8-13=0/266,7-15=-21/306,6-15=-258/0, 5-15=0/602,5-16=-611/0,4-16=0/333, 8-12=867/0,10-12=0/690,4-17=-531/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at Jul[us Lee;P.E.4#34869. joint(s)except Qt=lb)18=136. 1109 Coastal Bay Boynton Sochi,FL'33435 I Job I russ I russ Type tyPly A0357907 58824 F07 Floor 1 1 Job Reference o tional Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 2014:35:21 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_2yswKKAlgbaKZg9uBZgTvThlnSklusZAAygkZgz4NKK 0-3-8 - 1-5-0 , 1-1-11 , 2-6-0 2-0 0 0 8 3 I 1-5-0 ,0-6-6 Sca e-1.26.9 3x4 3x3 11 3x4= 1.5x4 11 3x4= 3x4= 1.5x4 11 3x6= 5x6= 1 2 3 4 5 6 7 8 9 10 9v 18 17 16 15 14 13 12 11 3x6= 3x6= 1.5x4[I 1.5x4 11 3x6= 3x4= -3 8 1-8-8 8-2-11 9-2-11 10-2-11 13-9-7 15 2-7 5 8-1 -3- 1-5-0 6-6-3 1-0-0 1-0-0 3-6-11 1-5 Plate Offsets(X Y)— [2:Edge 0-2-41 [6:0-1-8 Edge] 17:0-1-8 Edge] [10:0-2-8,Edge],[12:0-1-8 Edgel,[17:0-2-8,Edgel LOADING(psf) SPACING- 14-0 CSI. DEFL. in (loc) I/deft L/d PLATES' GRIP TCLL 40.0 Plates Increase .1.00 TC 0.71 Vert(LL) -0.20 15-16 >931 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.69 Vert(TL) -0.35 15-16 >515 360 BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(TL) -0.04 10 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:82 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) 6)Gap between inside of top chord bearing and first BOT CHORD 2x4 SP M 30(flat) diagonal or vertical web shall not exceed 0.500in. WEBS 2x4 SP No.3(flat) BRACING- TOP CHORD LOAD CASE(S) Structural wood sheathing directly applied or 6-0-0 oc Standard purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 = 655/0-2-10 (min.0-1-8) 10 = 659/0-5-14 (min.0-1-8) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-877/0,3-4=-880/0,4-5=-1 98510, 5-6=-1985/0,6-7=-1963/0,7-8=-1046/0, 8-9=-1049/0,9-10=-780/0 BOT CHORD 16-17=0/1318,15-16=0/1963, 14-15=0/1963,13-14=0/1963,12-13=0/752 WEBS 6-16=250/182,5-16=-255/0,4-16=0/738, 4-17=620/0,7-13=-1023/0,10-12=0/987, 2-17=0/1113,9-12=-528/0,9-13=0/486 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)Provide mechanical connection(by others)of truss to bearing plate atjoint(s)1. 4)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d Julius Lee;P.E. #34869 (0.131"X 3")nails. Strongbacks to be attached to walls 1109 coastal Bay at their outer ends or restrained by other means. Boynton Beach,FL 33435 Job I toss I cuss Type City Ply Job Reference o tional A0357908 58824 FOB Floor I1 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:21 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH-72yswKKA1 gbaKZg9uBZgTvThl5SgaupfAAygkZgz4NKK 0-3-8 1-5-0 10-10-5 2-6-0 2-0-0 � cale-1:30.4 3x4= 4x4 3x3 11 3x4= 1.5x4 11 3x4= 3x4= 3x6 FP= 1.5x4 11 3x3 11 4x4 1 2 3 4 5 6 7 8 9 TA 10 11 12 13 o 0 22 21 20 19 18 17 16 15 14 4x6= 3x6 FP= 1.5x4 11 1.5x4 11 3x6= 4x6= 3x6= q 3�8 1-8 8 7-11-5 8-11-5 9-11-5, 15-9-12 17-2-12 17-9-2 Ora-8 1-5-0 6-2-13 1-0-0 1-0-0 5-10-7 1-5-0 6- Plate Offsets(X,Y)- [2:Edge,0-3-131 [4:0-1-12,Edgel [6:0-1-8 Edo_el [7:0-1-8 Edo_el,[10:0-1-12 Edg_el,[12:Edge,0-2-61 [15:0-2-0,Edgel LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.75 Vert(LL) -0.20 18-20 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.93 Vert(TL) -0.37 18-20 >574 360 BCLL 0.0 Rep Stress Incr YES WB 0.72 Horz(TL) -0.06 13 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:92 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) 5)"Semi-rigid pitchbreaks with fixed heels"Member BOT CHORD 2x4 SP No.2(flat) end fixity model was used in the analysis and design WEBS 2x4 SP No.3(flat) of this truss. BRACING- 6)Recommend 2x6 strongbacks,on edge,spaced at TOP CHORD 10-0-0 oc and fastened to each truss with 3-1 Od Structural wood sheathing directly applied or 6-0-0 oc (0.131".X 3")nails. Strongbacks to be attached to pudins. walls at their outer ends or restrained by other means. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. LOAD CASE(S) REACTIONS. (lb/size) Standard 1 = 76610-2-10 (min.0-1-8) 13 = 763/0-2-14 (min.0-1-8) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-1039/0,3-4=1043/0,4-5=-2394/0, 5-6=-2394/0,6-7=-2807/0,7-8=-2355/0, 8-9=-2355/0,9-10=-2355/0, 10-11=-1189/0,11-12=1180/0 BOT CHORD 20-21=0/1474,19-20=0/2807, 18-19=0/2807,17-18=0/2807, 16-17=0/2807,15-16=0/1427 WEBS 6-20=648/0,4-20=0/1017,4-21=-710/0, 7-16=681/0,10-16=0/1027,10-15=-559/0, 2-21=0/1319,11-15=-370/0, 12-15=0/1504 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Plate(s)atjoint(s)19 checked for a plus or minus 5 degree rotation about its center. 3)Plate(s)atjoint(s)8,3,11,18,6,17,7,5,20,4,9,16 ,10,21,2,15 and 12 checked for a plus or minus 0 degree rotation about its center. 4)Provide mechanical connection(by others)of truss to Jul[us Lee;P.E.#34869. bearing plate atjoint(s)1,13. 1109 Coastal Bay Boynton Beach FL'33435 Job Truss Fruss Type Qly Hly A0357909 58824 F09 Floor 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:22 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_W8QIYgBfRuiBBgk41GLiShEwys2rdGfKPcal5Hz4NKJ 0-3-8 r r 1-5-0 —I 2-6-0 2-0-0 O*F=� 3x4= 1.5x4 11 4x4 3x6= 1.5x4 II 3x4= 3x4= 3x6 FP= 3x4= 3x6= 5x6= 1 2 3 4 5 6 7 8 9 10 1112 13 1--tS 24 23 22 21 2019 18 17 1615 14 3x3= 3x6= 3x8 MT20H FP-- 1.5x4 11 3x6= 4x10= 4x6= 1.5x4 11 Or3,8 1-8-8 2 4-1¢ 7-7-15 8-7-15,9-7-15, 17-10-1 19-3-1 19-9 7 0-3-8 1'� 5� 5-3-0 1-0-0 1-0-0 8-2-2 1-5-0 Plate Offsets MY)— [2:Edge,0-3-131 [4:0-1-8 Edgel [6:0-1-8 Edge] [7:0-1-8 Edgel [13:0-2-8,Edge] [16:0-4-4,Edgel,[21:0-2-8 Edge],[23:0-1-8,Edgel LOADING(psf) SPACING- 14-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.74 Vert(LL) -0.27 17-18 >851 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.80 Vert(TL) -0.52 17-18 >447 360 MT20H 187/143 BCLL 0.0 Rep Stress Incr YES• WB 0.73 Horz(TL) -0.07 13 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:105 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) 4)Provide mechanical connection(by others)of truss BOT CHORD 2x4 SP M 30(flat) to bearing plate at joint(s)1. WEBS 2x4 SP No.3(flat) 5)"Semi-rigid pitchbreaks with fixed heels"Member BRACING- end fixity model was used in the analysis and design TOP CHORD of this truss. Structural wood sheathing directly applied or 5 4-14 oc 6)Recommend 2x6 stongbacks,on edge,spaced at purlins. 10-0-0 oc and fastened to each truss with 3-10d BOT CHORD (0.131"X 3")nails. Strongbacks to be attached to Rigid ceiling directly applied or 10-0-0 oc bracing. walls at their outer ends or restrained by other means. REACTIONS. (lb/size) 7)Gap between inside of top chord bearing and first 1 = 831/0-2-10 (min.0-1-8) diagonal or vertical web shall not exceed 0.500in. 13 = 834/0-5-14 (min.0-1-8) FORCES. (lb) LOAD CASE(S) Max.Comp./Max.Ten.-All forces 250(lb)or less Standard except when shown. TOP CHORD 2-3=-1214/0,3-4=1439/0,4-5=-2560/0, 5-6=-2560/0,6-7=3270/0,7-8=-3114/0, 8-9=-3114/0,9-10=-3114/0, 10-1 1=-1 165/0,11-12=1161/0, 12-13=-998/0 BOT CHORD 22-23=0/1164,21-22=011460, 20-21=0/3270,19-20=0/3270, 18-19=0/3270,17-18=0/3270, 16-17=0/2332,15-16=0/956 WEBS 6-21=-930/0,4-21=0/1211,4-22=-514/0, 7-17=476/121,10-17=01865, 10-1 6=-1290/0,12-16=0/688,3-23=-908/0, 3-22=0/596,2-23=0/1535,12-15=-776/0, 13-15=0/1263 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are MT20 plates unless otherwise indicated. 3)Plates checked for a plus or minus 0 degree rotation Jul[us Lee,P.E. #34869 about its center. t109 Coastal Bay Boynton Beach,FL 33435 a + A 1 Job russ runs I ype Qty Hly 58824 1"10 Floor 1 1 Job Reference(optional) A0357910 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Ina Fri Jun 20 14:35:22 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_w8QIYgBfRuiBBgk41GLiShEtys5ZdDvKPca15Hz4NKJ 0-3-6 1-5-0 1�-11 2-0-0' r 0-0 1-4-0 F le=1:38.1 1.5x4 II 4x4 3x6= 1.5x4 11 3x4= 1.5x4 11 3x3= 1.5x4 11 3x3= 3x6 FP= 3x4= 3x3 II 5x6— 1 2 3 4 5 6 7 8 9 1011 12 13 14 15 r d 'id 26 25 24 23 22 21 20 19 18 17 16 3x3= 5x6= 5x6= 3x6 FP= 4x6 11 3x6 11 5x6= 3x6 FP= 5x6= 7x6 II 3x3= 3x3= Or3r6 1-8 6 7-4-9 8 4-9 9 4 9, 21-2-9 21-9i1 0-3-6r 0+ 5-8-3 1-0-0 TV 11-10-0 6- Plate Offsets(X,Y)— [2:Edge,0-3-11],[5:0-1-12,Edge],[12:0-1-12,Edge],[14:0-2-9,Edge],[17:0-3-0,Edge],[18:0-3-0,Edge],[20:0-3-0,Edge],[21:0-3-0,0-0-0],[22:0-3-0 ,Edge],[24:0-3-0,Edgel,[25:0-1-8,Edgel LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.94 Vert(LL) -0.36 20-21 >717 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.63 Vert(TL) -0.70 20-21 >372 360 BCLL 0.0 Rep Stress Incr YES WB 0.91 Horz(TL) -0.11 15 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix) Weight:140 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) 4)"Semi-rigid pitchbreaks with fixed heels"Member BOT CHORD 2x4 SP No.2(flat)*Except* end fixity model was used in the analysis and design 132,133:2x4 SP M 30(flat) of this truss. WEBS 2x4 SP No.3(flat) 5)Recommend 2x6 strongbacks,on edge,spaced at BRACING- 10-0-0 oc and fastened to each truss with 3-10d TOP CHORD (0.131"X 3")nails. Strongbacks to be attached to Structural wood sheathing directly applied. walls at their outer ends or restrained by other means. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) LOAD CASE(S) 1 = 939/0-2-8 (min.0-1-8) Standard 15 = 935/0-5-14 (min.0-1-8) FORCES. (lb) Max.Comp.lMax.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-1 36510,3-4=2194/0,4-5=2194/0, 5-6=-4166/0,6-7=-4166/0,7-8=-4467/0, 8-9=4467/0,9-10=-3588/0, 10-11=-3588/0,11-12=3588/0, 12-13=-1505/0,13-14=-1491/0 BOT CHORD 24-25=0/1370,23-24=0/3300, 22-23=0/3300,21-22=0/4166, 20-21=0/4166,19-20=0/4167, 18-19=0/4167,17-18=0/2669 WEBS 7-21=360/0,5-22=0/1079,5-24=-1265/0, 3-24=0/1057,7-20=-187/571,9-20=0/353, 9-18=663/0,12-18=0/1051, 12-17=-1332/0,13-17=-468/0, 14-17=0/1906,3-25=917/0,2-25=0/1698 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Plates checked for a plus or minus 0 degree rotation about its center. Julius Lee;P.E. #34869 3)Provide mechanical connection(by others)of truss to 1109 Coastal Bay bearing plate at joint(s)1. Boynkon Beach,.FL 33435 Job I russ I russ Type Qty my A0357911 58824 F11 Floor 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Pdnt 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:23 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=_K_gIOBHCCg2p_JGJ_sx_um8xGQIMgVTdGJrd]z4NKl 0-3-8 Q-51 2-0-0 2-0-0 I� 1�5-0 S le=1:41.9 1.5x4 II 3x3= 1.5x4 II 1.5x4 II 3x6= 4x4= 1.5x4 II 3x3= 1.5x4 II 3x3= 3x6 FP= 4x4= 4x6- 6x6- 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TI LOIN ICI¢ d 29 28 27 26 25 24 23 22 21 20 19 18 17 3x3= 3x6 FP= 3x6 11 3x6.1I 3x6 FP= 3x3= 3x3= 3x3= 23-10-2 Or3,8 1 8-8 12-M ,13-9-8i 14 9-8i 21-10-12 233-12 i , 0-33 1S 0 11-1-0 1-0-0 1-0-0 7-1-4 1S-0 Plate Offsets(X,Y)- [2:0-0-2,Edge],[5:0-1-12,Edge],[13:0-1-12,Edge],[16:0-2-12,Edge],[18:0-1-8,Edge],[19:0-3-0,Edge],[20:0-3-0,Edge],[22:0-3-0,0-0-0],[24:0-3-0 Edgel,[26:0-3-0,Edge] [27:0-3-0 Edge] [28:0-3-0 Edgel LOADING(psf) SPACING- 1-4-5 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL , 40.0 Plates Increase 1.00 TC 0.54 Vert(LL) -0.39 23-24 >712 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.69 Vert(TL) -0.76 23-24 >367 360 BCLL 0.0 Rep Stress Incr YES WB 0.95 Horz(TL) -0.12 16 n/a n/a BCDL 10.0 Code FBC201 OITP12007 (Matrix) Weight:157 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat)*Except* NOTES- T2:2x4 SP M 30(flat) . 1)Unbalanced floor live loads have been considered BOT CHORD 2x4 SP No.2(flat)*Except* for this design. B2:2x4 SP M 30(flat) 2)All plates are 5x6 MT20 unless otherwise WEBS 2x4 SP No.3(flat) indicated. BRACING- 3)Plates checked for a plus or minus 0 degree TOP CHORD Structural wood sheathing directly applied or 5-9-11 cc rotation about its center.4)Provide mechanical connection(by others)of truss purlins. to bearing plate at joint(s)1. BOT CHORD 5)"Semi-rigid pitchbreaks with fixed heels"Member Rigid ceiling directly applied or 10-0-0 cc bracing. end fixity model was used in the analysis and design REACTIONS. (lb/size) of this truss. 1 = 1026/0-2-10 (min.0-1-8) 6)Recommend 2x6 strongbacks,on edge,spaced at 16 = 1030/0-5-14 (min.0-1-8) 10-0-0 cc and fastened to each truss with 3-1 Od (0.131"X 3")nails. Strongbacks to be attached to FORCES. (lb) walls at their outer ends or restrained by other means. Max.Comp./Max.Ten.-All forces 250(lb)or less 7)Gap between inside of top chord bearing and first except when shown. diagonal or vertical web shall not exceed 0.5001n. TOP CHORD 2-3=-1609/0,3-4=-1932/0,4-5=-1920/0, LOAD CASE(S) 5-6=-4196/0,6-7=-4196/0,7-8=-5198/0, Standard 8-9=-5198/0,9-1 0=-501 0/0, 10-11=-4096/0,11-12=-4096/0, 12-13=-4096/0,13-14=-1831/0, 14-15=-1836/0,15-16=-1323/0 BOT CHORD 27-28=0/1544,26-27=0/3205, 25-26=0/4842,24-25=0/4842, 23-24=0/5010,22-23=0/5010, 21-22=0/5010,20-21=0/5010, 19-20=0/3116,18-19=0/1268 WEBS 9-23=328/37,10-22=0/388, 9-24=299/499,7-24=0/419,7-26=-739/0, 5-26=0/1133,5-27=-1471/0,3-27=0/730, 10-20=-1202/0,13-20=0/1122, 13-19=-1470/0,15-19=0/951, 3-28=-1135/0,15-18=-950/0,2-28=0/1995, 16-18=011640 Julius Lee%P.E. #34869 1109 Coastal Bay Boynton Beach,.FL'33435 Job Truss I russ Type �Qty ply A0357912 58824 F12 Floor 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 2014:35:23 2014 Page 1 ID:YRb6ZZg4rA7iabCgp8wopfz7lFL K._gIOBHCCg2p_JGJ-sx um7UGRvMkRTdGJrdjz4NKl 0-3-8 1-8-9 i 2-6-0 � 2-0-0 0 4H0! S le=1:45.3 3x6 FP= 3x6 FP= 5x6= 5x6= 5x6= 4x6 II 5x6= 5x6= 6x12= 1 2 3 4 5 6 7 8 9 10 11 12Tj 13 1415 d tolNimI� d 27 26 25 2423 22 21 20 19 18 17 16 3x3= 6x6= 5x8= 3x6 FP= 5x6= 5x6= 5x10= 3x3= 5x6= 3x6 FP= 25-10-7 Or3i8 2-1-9 12-6-1 i131-1,14-6-11 24-10-9 25-4r1 038 1-10-1 10 1-0-0 1-0-0 10�� S 0-0-6 Plate Offsets(X,Y)- [2:0-0-2,Edge],[3:0-1-8,Edge],[5:0-3-0,Edge],[8:0-3-0,Edge],[9:0-3-0,0-0-0],[11:0-1-8,Edge],[12:0-3-0,Edge],[14:0-5-8,Edge],(18:0-3-12,Edge], [19:0-1-8,Edge] [21:0-1-8 Edge],[23:0-3-0,Edgel,[25:0-3-12,Edge],[26:0-1-8,Edgel LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.63 Vert(LL) -0.43 22 >712 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.62 Vert(TL) -0.83 22 >368 360 BCLL 0.0 Rep Stress Incr YES WB 0.70 Horz(TL) -0.11 15 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:197 lb FT=O%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) 3)Plate(s)atjoint(s)27,10,22,8,21,9,6,23,5,4, BOT CHORD 2x4 SP M 30(flat) 25,3,26,26,11,19,12,13,18,14,2,17 and 7 WEBS 2x4 SP No.2(flat)*Except* checked for a plus or minus 0 degree rotation about W2,W4:2x4 SP,No.3(flat) its center. BRACING-TOP CHORD 4)minus 5 degree rotation about its center.Plate(s)at joint(s)24 and 20 checked for a plus or i Structural wood sheathing directly applied or 6-0-0 cc 5)Provide mechanical connection(by others)of truss puriins. to bearing plate at joint(s)1. BOT CHORD 6)"Semi-rigid pitchbreaks with fixed heels"Member Rigid ceiling directly applied or 10-0-0 cc bracing. end fixity model was used in the analysis and design REACTIONS. (lb/size) of this truss. 1 = 1093/0-2-10 (min.0-1-8) 7)Required 2x6 strongbacks,on edge,spaced at 15 = 1097/0-5-14 (min.0-1-8) 10-0-0 cc and fastened to each truss with 3-1 Od (0.131"X 3")nails. Strongbacks to be attached to FORCES. (lb) walls at their outer ends or restrained by other means. Max.Comp./Max.Ten.-All forces 250(lb)or less 8)Gap between inside of top chord bearing and first except when shown. diagonal or vertical web shall not exceed 0.500in. TOP CHORD 2-3=-2032/0,3-4=3849/0,4-5=-3849/0, LOAD CASE(S) 5-6=-6076/0,6-7=6076/0,7-8=6076/0, Standard 8-9=-6286/0,9-10=-6286/0, 10-11=-6286/0,11-12=5557/0, 12-13=-2679/0,13-14=2679/0, 14-15=-325/0 BOT CHORD 25-26=0/2032,24-25=0/5202, 23-24=0/5202,22-23=0/6286, 21-22=0/6286,20-21=0/5557, 19-20=0/5557,18-19=0/4353,17-18=0/395 WEBS 8-23=693/246,5-23=0/949,5-25=-1469/0, 3-25=0/1965,3-26=-1183/0, 11-21=0/1097,11-19=-469/0, 1 2-19=0/1 307,12-18=-1818/0, 1 4-1 8=0124 71,2-26=0/2380, 14-17=-1173/0,15-17=0/1237 NOTES- 1)Unbalanced floor live loads have been considered for Julius Lee,P.E. #34869' this design. 1109 Coastal Bay 2)All plates are 3x6 MT20 unless otherwise indicated. Boynton Beach,.FL'33435 Job I russ russ Type Qty Ply A0357913 58824 F13 Floor 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:24 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wapfz7lH_SXY3zMCvzWyvQ8uSshOAX6JMpfnB58Gcsw3OA9z4NKH 0-3-8 I 1-5-3 1 2-6-0 2-0-0 1N7 Scale=1:46.9 4x6 II 3x6 FP= 3x6 FP= 6x6= 5x6= 5x6= 4x6 II 5x6= 5x6= 5x6= 1 2 3 4 5 6 7 8 9 10 11 12Tj 13 14 15 I ITIII CS lO IN I�I¢ O 27 26 25 24 23 22 21 20 19 18 17 16 3x3=6x6= 5x8= 3x8 MT20H FP-- 5x8= 6x8= 5x6 11 3x3= 3x3= 5x8= 3x8 MT20H FP= 14-2-11 26-3-14 0,3,81 12-2-11 13-2-11 24-7-3 , 26-0-7 , 0f-81�- ol1 10� 1-00 1-0-0 10-4-8 1-5�037 Plate Offsets(X,Y)— [3:0-1-8,Edge],[5:0-3-0,Edge],[8:0-3-0,Edge],[9:0-3-0,Edge],112:0-3-0,Edge],[14:0-1-8,Edge],[15:0-2-9,Edge],[17:0-3-0,Edge],[18:0-2-4,Edge], H9:0-4-0,Edgel,[21:0-3-0,0-0-01,[24:0-4-0,Edgel,[25:0-4-0,Edgel,[26:0-1-8,Edge] LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.34 Vert(LL) -0.42 21-22 >745 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.62 Vert(TL) -0.81 21-22 >384 360 MT20H 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.85 Horz(TL) -0.10 15 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:201 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP M 30(flat) NOTES- BOT CHORD 2x4 SP M 30(flat) 1)Unbalanced floor live loads have been considered WEBS 2x4 SP No.3(flat)*Except* for this design. W3,W1:2x4 SP No.2(flat) 2)All plates are MT20 plates unless otherwise BRACING- indicated. TOP CHORD 3)All plates are 3x6 MT20 unless otherwise Structural wood sheathing directly applied or 6-0-0 cc indicated. purlins. 4)Plates checked for a plus or minus 0 degree BOT CHORD rotation about its center. Rigid ceiling directly applied or 10-0-0 oc bracing. 5)Provide mechanical connection(by others)of truss REACTIONS. (lb/size) to bearing plate atjoint(s)1,15. = 1124/0-2-10 (min.0-1-8) 6)"Semi-rigid pitchbreaks with fixed heels"Member 1 15 = 112 /0-2-1 (min.0-1-8) end fixity model was used in the analysis and design of this truss. 7)Required 2x6 strongbacks,on edge,spaced at FORCES. (lb) Max.Comp./Max.Ten.-All farces 250(lb)or less 10-0-0 cc and fastened to each truss with 3-10d except when shown. (0.131"X 3")nails. Strongbacks to be attached to P CHORD walls at their outer ends or restrained by other means. TOP 2-3 CHOl0,3 4=-3802/0,4-5=-3802/0, 8)Gap between inside of top chord bearing and first 5-6=-6282/0,6-7=6282/0,7-8=-6282/0, diagonal or vertical web shall not exceed 0.500in. 8-9=-6685/0,9-10=-6155/0, 10-11=-6155/0,11-12=6155/0, LOAD CASE(S) 12-13=-3526/0,13-14=-3526/0, Standard 14-15=-1405/0 BOT CHORD 25-26=0/1834,24-25=015275, 23-24=0/6685,22-23=0/6685, 21-22=0/6685,20-21=0/6685, 19-20=0/6685,18-19=0/5068, 17-18=0/1405 WEBS 8-24=859/113,5-24=0/1093, 5-25=-1600/0,3-25=0/2129,3-26=-1281/0, 9-19=957/15,12-19=0/1180, 12-18=-1674/0,14-18=0/2295, 14-17=-1065/0,2-26=0/2265, 15-17=0/1789 Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FIL 33435 a f 4 1 Job Truss I russ Type Qty ply A0357914 58824 F14 Floor 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s Mayy 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 2014:35:24 2014 Page 1 I D:YRb6ZZgQrA7 is bOq p8wopfz7lH_-SXY3zM Cvz WyvQ8 u Ssh OAX6JImfn 0566csw3OA9z4N KH 0-3-8 1-1-13 2-6-0 2-0-0 1-3-11 0 3 7 �� l--[Scale=1:46.4 4x6 I I 3x6 FP= 3x6 FP= 6x6= 5x6= 5x6= 4x6 II 5x6= 5x6= 5x6= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 O I4IN I�I� d 27 26 25 24 23 22 21 20 19 18 17 16 3x3= 5x8= 3x8 MT20H FP-- 5x8= 5x8= 5x6=3x3= 5x6 11 5x8= 3x8 MT20H FP= 1-6-13 13-11-5 26-M p,3 8 11-11-5 12-11-5 24-0-13 25-9-1 , , 0L-81-3-5 10-4-8 1-0-0 1-0-0 10-4-8 1-5403-7 Plate Offsets(X,Y)— [3:0-1-8,Edge],[5:0-3-0,Edge],[8:0-3-0,Edge],[9:0-3-0,Edge],(12:0-3-0,Edge],[14:0-1-8,Edge],[15:0-2-9,Edge],[17:0-1-8,Edge],[18:0-2-4,Edge], 119:0-4-0,Edgel,[21:0-3-0,0-0-01,[24:0-4-0,Edge],[25:0-3-12,Edgel,[26:0-3-0,Edgel LOADING(psf) SPACING- 14-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.60 Vert(LL) -0.44 21-22 >704 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.60 Vert(TL) -0.85 21-22 >363 360 MT20H 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.99 Horc(TL) -0.11 15 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:199 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) NOTES- BOT CHORD 2x4 SP M 30(flat) 1)Unbalanced floor live loads have been considered WEBS 2x4 SP No.3(flat)`Except' for this design. W3:2x4 SP No.2(flat) 2)All plates are MT20 plates unless otherwise BRACING- indicated. TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc 3)All plates are 3x6 MT20 unless otherwiseindicated. ROT CHORD purT 4)Plates checked for a plus or minus 0 degree rotation about its center. Rigid ceiling directly applied or 10-0-0 oc bracing. 5)Provide mechanical connection(by others)of truss REACTIONS. (lb/size) to bearing plate atjoint(s)1,15. 1 = 1112/0-2-10 (min.0-1-8) 6)"Semi-rigid pitchbreaks with fixed heels"Member 15 = 1116/0-2-15 (min.0-1-8) end fixity model was used in the analysis and design of this truss. FORCES. (lb) 7)Required 2x6 strongbacks,on edge,spaced at Max.Comp./Max.Ten.-All forces 250(lb)or less 10-0-0 oc and fastened to each truss with 3-10d except when shown. (0.131"X 3")nails. Strongbacks to be attached to TOP CHORD walls at their outer ends or restrained by other means. 2-3=-1552/0,3-4=3559/0,4-5=-3559/0, 8)Gap between inside of top chard bearing and first 5-6=-6085/0,6-7=6085/0,7-8=-6085/0, diagonal or vertical web shall not exceed 0.500in. 8-9=-6546/0,9-10=-6044/0, 10-11=-6044/0,11-12=6044/0, LOAD CASE(S) 12-13=-3474/0,13-14=-3474/0, Standard 14-15=-1384/0 BOT CHORD 25-26=0/1552,24-25=015066, 23-24=0/6546,22-23=0/6546, 21-22=0/6546,20-21=0/6546, 19-20=0/6546,18-19=0/4995, 17-18=0/1384 WEBS 8-24=-896/61,5-24=0/1107,5-25=-1635/0, 3-25=0/2172,3-26=1343/0, 9-19=928/29,12-19=0/1139, 12-18=-165110,14-18=0/2261, 14-17=-1052/0,2-26=0/2080, 15-17=0/1765 Julius Lee;P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 � D o russ 35 cuss Type ty y A07915 58824 F15 Floor 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:25 2014 Page 1 ID:YRb6ZZgGirA7iabOgp8wopfz7lH_wj6RAiDXkp4m2HTfQPvP4JsSn37ggaNm5Zoyicz4NKG 0-3-8 10-, 2-6-0 2-0-0 1-3-11 N 0 3 7 ~� Srale=1:45.8 6x6= 3x6 FP= 3x6 FP- 5x6= 5x6= 4x6 11 4x6 11 5x6= 5x6= 5x6= 1 2 3 4 5 6 7 8 9 10 11 12 TI 13 14 15 O 27 26 25 24 23 22 21 20 19 18 17 16 5x6 11 5x8= 3x8 MT20H FP-- 5x8.= 5x8= 5x6=3x3= 5x8= 3x8 MT20H FP-- 1-3-7 13-7-15 25-9-2 0 M i 11-7-15 12-7-15 24-0-7 i 255-11, , 0-3-8 10-4-8 1-0 0 1-0-0 10-4-8 1-5�0-3-7 0-11-15 Plate Offsets(X,Y)— [3:0-1-8,Edge],[5:0-3-0,Edge],[8:0-3-0,Edge],[9:0-3-0,Edge],[12:0-3-0,Edge],[14:0-1-8,Edge],[15:0-2-9,Edge],[17:0-1-8,Edge],[18:0-2-4,Edge], It9:0-4-0 Edge] [21:0-3-0 0-0-0] [24:0-4-0 Edge] [25:0-3-12,Edge] [26:0-3-0,Edge] LOADING(psf) SPACING- 1-4-0 CS1. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.58 Vert(LL) -0.42 21-22 >726 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.59 Vert(TL) -0.82 21-22 >374 360 MT20H 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.93 Horz(TL) -0.11 15 n/a n/a BCDL 10.0 Code FBC2010lrP12007 (Matrix) Weight:197 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) NOTES- BOT CHORD 2x4 SP M 30(flat) 1)Unbalanced floor live loads have been considered WEBS 2x4 SP No.3(flat)'Except' for this design. W3:2x4 SP No.2(flat) 2)All plates are MT20 plates unless otherwise BRACING- indicated. TOP CHORD 3)All plates are 3x6 MT20 unless otherwise Structural wood sheathing directly applied or 6-0-0 oc indicated. purlins. 4)Plates checked for a plus or minus 0 degree BOT CHORD rotation about its center. Rigid ceiling directly applied or 10-0-0 oc bracing. 5)Provide mechanical connection(by others)of truss REACTIONS. (Ib/size), to bearing plate atjoint(s)1,15. 1 = 1100/0-2-10 (min.0-1-8) 6)"Semi-rigid pitchbreaks with fixed heels"Member 15 = 1104/0-2-15 (min.0-1-8) end fixity model was used in the analysis and design of this truss. FORCES. (lb) 7)Required 2x6 strongbacks,on edge,spaced at Max.Comp./Max.Ten.-All farces 250(lb)or less 10-0-0 oc and fastened to each truss with 3-10d except when shown. (0.131"X 3")nails. Strongbacks to be attached to P CHORD walls at their outer ends or restrained by other means. TOP 2-3 CHO/0,3 4=3321/0,4-5=-3321/0, 8)Gap between inside of top chord bearing and first 5-6=-5899/0,6-7=-5899/0,7-8=-5899/0, diagonal or vertical web shall not exceed 0.500in. 8-9=-6403/0,9-10=-5944/0, 10-1 1=-5944/0,11-12=5944/0, LOAD CASE(S) 12-13=-3430/0,13-14=3430/0, Standard 14-15=-1368/0 BOT CHORD 25-26=011268,24-25=0/4853, 23-24=0/6403,22-23=0/6403, 21-22=0/6403,20-21=0/6403, 19-20=0/6403,18-1 9=0/4922, 17-18=0/1368 WEBS 8-24=922/20,5-24=0/1136,5-25=-1663/0, 3-25=0/2221,3-26=1439/0, 9-19=887/56,12-19=0/1111, 12-18=-1620/0,14-18=0/2230, 14-17=-1039/0,2-26=0/1944, 15-17=0/1746 Jullus Lee;P.E. 934869. 1109 coastal Bay. Boynton Beachz"FL 33435 t r Job I russ russ Type Qty Ply A0357916 58824 F16 Floor 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,Fl.34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:25 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=wj6RAiDXkp4m2HTfQPvP4JsS137ggaQm5Zoyicz4NKG 0-3-8 2-6-0 2-0-0 1-3-11 N 0 3 7 ~� Scale=1:45.3 7x6= 3x6 FP= 3x6 FP= 5x6= 5x6= 4x6 I I 4x6 11 5x6= 5x6= 5x6= 1 2 3 . 4 5 6 7 8 9 10 11 12 Tj 13 14 15 II d 27 26 25 24 23 22 21 20 19 18 17 16 4x8 I I 5x10= 3x8 MT20H FP-- 5x8= 5x8= 5x6=3x3= 5x8= 3x8 MT20H FP-- 1-0-1 255-11 OT38 , 11-4-9 12-4-9,13�-9, 23-9-1 25-2-4 i , 0-3-8 104-8 1-0-0 1-0-0 10-4-8 1S_0"7 0-8-9 Plate Offsets MY)— [3:0-1-8,Edge],[5:0-3-0,Edge],[8:0-3-0,Edge],[9:0-3-0,Edge],[12:0-3-0,Edge],[14:0-1-8,Edge],[15:0-2-9,Edge],[17:0-1-8,Edge],[18:0-2-4,Edge], [19:0-4-0 Edgel,[21:0-3-0 0-0-01,[24:0-4-4 Edge1,[21:0-3 0-0 [24:0-4-0,Edgel,[25:0-4-8,Edgel[25:0-4-8,Edgel LOADING(psf) SPACING- 1-4-5 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.58 Vert(LL) -0.41 21-22 >733 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.59 Vert(TL) -0.80 21-22 >378 360 MT20H 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.92 Horz(TL) -0.11 15 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:195 lb FT=O%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) 3)All plates are 3x6 MT20 unless otherwise BOT CHORD 2x4 SP M 30(flat) indicated. WEBS 2x4 SP No.3(flat)`Except' 4)Plates checked for a plus or minus 0 degree BRACING- W3:2x4 SP No.2(flat) rotation about its center. ' TOP CHORD 5)Provide mechanical connection(by others)of truss Structural wood sheathing directly applied or 6-0-0 cc to bearing plate at joint(s)1,15. puriins. 6) 'Semi-rigid pitchbreaks with fixed heels"Member BOT CHORD end fixity model was used in the analysis and design of this truss. Rigid ceiling directly applied or 10-0-0 oc bracing. 7)Required 2x6 strongbacks,on edge,spaced at REACTIONS. (Ib/size) 10-0-0 oc and fastened to each truss with 3-10d = 1109/0-2-10 (min.0-1-8) (0.131"X 3")nails. Strongbacks to be attached to 1 15 = 1109/0-2-15 (min.0-1-8) walls at their outer ends or restrained by other means. 8)Gap between inside of top chord bearing and first FORCES. (lb) diagonal or vertical web shall not exceed 0.500in. Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. LOAD CASE(S) TOP CHORD Standard 2-3=-997/0,3-4=-3145/0,4-5=-3145/0, 5-6=-5825/0,6-7=-5825/0,7-8=-5825/0, 8-9=-6382/0,9-10=-5959/0, 10-1 1=-5959/0,11-12=5959/0, 12-13=-3451/0,13-14=3451/0, 14-15=-1379/0 BOT CHORD 25-26=01997,24-25=0/4730,23-24=0/6382, 22-23=0/6382,21-22=0/6382, 20-21=0/6382,19-20=0/6382, 18-19=0/4943,17-18=0/1379 WEBS 8-24=-967/0,5-24=0/1189,5-25=-1721/0, 3-25=0/2324,3-26=-1631/0,9-19=-862/84, 12-19=0/1103,12-18=-1620/0, 14-18=0/2242,14-17=-1047/0, 2-26=0/1937,15-17=0/1759 NOTES- 1)Unbalanced floor live loads have been considered for this design. Jullus Lee;P.E. #34869 2)All plates are MT20 plates unless otherwise indicated. 1109 Coasta6Bay Boynton Beaeh,'FL 33435 o -as I russ Type y y A0357917 58824 �1`17 Floor 1 1 Job Reference o tional Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Ina Fri Jun 20 14:35:26 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_OvgpN2E9V7CdgR2r 6QecXOd4TOEZ3OvJDYVE2z4NKF 0-3-9 1-5-0 1 4 7 , 2-6-0 2-0-0 1-3-12 0 3 7 �� Scale=1:44.8 4x6 11 3x6 FP= 3x6 FP= 6x6= 5x6= 5x6= 4x6 II 5x6= 5x6= 5x6= 1 2 3 4 5 6 7 8 9 10 11 12 Tj 13 14 15 l� 1 �1 d 1' NI�1� O 27 26 25 24 23 22 21 20 19 18 17 16 3x3= 6x6= 5x8= 5x8= 3x6 FP= 4x6 II 5x6= 5x8= 5x6=3x3= 3x3= 3x6 FP= 25-2-3 0 3,9 1�-9 11-1-0 ,12-1-0,13-1-0, 23-" 12 110 10-12 0-3-9 1 S-0 9-4-7 1-0 0 1-0-0 104-8 1-5�13-7 Plate Offsets(X,Y)- [3:0-1-8,Edge],[5:0-3-0,Edge],[8:0-3-0,Edge],[9:0-3-0,0-0-0],[11:0-3-0,Edge],[12:0-3-0,Edge],[14:0-1-8,Edge],[15:0-2-9,Edge],[17:0-1-8,Edge], [18:0-2-4 Edgel [19:0-1-8 Edgel [21:0-3-0 Edge] [24:0-4-0,Edge] 125:04-0,Edgel,[26:0-1-8 Edgel LOADING(pso SPACING- 1-4-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.61 Vert(LL) -0.42 21 >710 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.90 Vert(TL) -0.81 21-22 >367 360 BCLL 0.0 Rep Stress Incr YES WB 0.81 Horz(TL) -0.10 15 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:193 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) NOTES- BOT CHORD 2x4 SP No.2(flat) 1)Unbalanced floor live loads have been considered WEBS 2x4 SP No.3(flat)*Except* for this design. W4,W1:2x4 SP No.2(flat) 2)All plates are 3x6 MT20 unless otherwise BRACING- indicated. TOP CHORD 3)Plate(s)atjoint(s)27,10,22,8,21,9,6,24,5,4, Structural wood sheathing directly applied or 6-0-0 cc 25,3,11,19,12,13,18,14,17,7,15,26,26,2 and purlins. 16 checked for a plus or minus 0 degree rotation BOT CHORD about its center. Rigid ceiling directly applied or 10-0-0 cc bracing. 4)Plate(s)at joint(s)23 and 20 checked for a plus or REACTIONS. (lb/size) minus 5 degree rotation about its center. = 1075/0-2-11 (min.0-1-8) 5)Provide mechanical connection(by others)of truss 1 15 = 107 /0-2-15 (min.0-1-8) to bearing plate atjoint(s)1,15. 6)"Semi-rigid pitchbreaks with fixed heels"Member FORCES. (lb) end fixity model was used in the analysis and design of this truss. Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. 7)Required 2x6 strongbacks,on edge,spaced at P CHORD 10-0-0 cc and fastened to each truss with 3-10d TOP 4=/0,3 2849/0,4-5=-2849/0, (0.131"X 3")nails. Strongbacks to be attached to 2-3CHO 5-6=-5527/0,6- =2847/0,7-8=-5527/0, walls at their outer ends or restrained by other means. 8-9=-6108/0,9-10=-6108/0, 8)Gap between inside of top chord bearing and first 10-11=-6108/0,11-12=5755/0, diagonal or vertical web shall not exceed 0.500in. 12-13=-3348/0,13-14=-3348/0, 14-15=-1339/0 LOAD CASE(S) BOT CHORD Standard 25-26=0/1718,24-25=0/4418, 23-24=0/6108,22-23=0/6108, 21-22=0/6108,20-21=0/5755, 19-20=0/5755,18-19=0/4773, 17-18=0/1339 WEBS 8-24=-970/0,5-24=0/1204,5-25=-1704/0, 3-25=0/1396,11-21=-126/794, 11-19=-347/0,12-19=0/1066, 12-18=-1547/0,14-18=0/2173, 14-17=-1014/0,15-17=0/1706, 3-26=1225/0,2-26=0/2130 Jullus Lee;P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 i 1 Job I russ Truss Type Qy y A0357918 58824 F18G FLOOR GIRDER 1 2 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:26 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH--OvgpN2E9V7CdgR2r 6QecXOhKTSDZ5fvJDYVE2z4NKF —11-9� 2-6-0 2-0-0 3-1-4 Scale=1:41.7 4x6= 1.5x4 11 3x4= 1.5x4 11 3x4= 1.5x4 11 5x6= 3x4= 1.5 11 4x8= 1 2 3 4 5 6 7 8 9 10 lu "I TP ; I 19. 18 17 16 15 14 13 12 11 2x4 II 3x8= 3x8= 4x6= 3x4= 3x4= 5x8= 3x4 II 1.5x4 11 0-gr12 10-9-9 ,11-9-912-9-9 24-9-13 24-,'10-9 0- -12 10-8-13 1-0-0 1-0-0 12-0-4 0- '-12 Plate Offsets(X Y)— [1:0-2-4 0-2-01 [7:0-3-0,0-3-01,[10:0-4-0 0-1-81,[12:0-1-12 0-2-01 LOADING(psf) SPACING- 0-11-3 CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.34 Vert(LL) -0.41 13-14 >706 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.64 Vert(TL) -0.80 13-14 >362 360 BCLL 0.0 Rep Stress Incr NO WB 0.67 Horz(TL) 0.09 11 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:232 Ito FT=0% LUMBER- TOP CHORD 2x4 SP M 31 'Except` 2)All loads are considered equally applied to all plies, 71:2x4 SP M 30 except if noted as front(F)or back(B)face in the BOT CHORD 2x4 SP M 31 LOAD CASE(S)section.Ply to ply connections have WEBS 2x4 SP No.3'Except* been provided to distribute only loads noted as(F)or W1:2x8 SP No.2,W5:2x4 SP M 30 BRACING- (B),unless otherwise indicated. TOP CHORD 3)Unbalanced floor live loads have been considered Structural wood sheathing directly applied or 5-6-6 oc for this design. pudins, except end verticals. 4) ,18,1 ,7,8,t12 19,1,11,10,15,5,plus 6,r 17, BOT CHORD 3,2,18,13,7,8,12 and 9 checked for a plus or minus 0 degree rotation about its center. Rigid ceiling directly applied or 10-0-0 oc bracing. 5)Plate(s)at joint(s)16 checked for a plus or minus 4 REACTIONS. (lb/size) degree rotation about its center. 19 = 1003/Mechanical 6)Refer to girder(s)for truss to truss connections. 11 = 2297/Mechanical 7)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design FORCES. (lb) of this truss. Max.Comp./Max.Ten.-All forces 250(lb)or less 8)Required 2x6 strongbacks,on edge,spaced at except when shown. 10-0-0 oc and fastened to each truss with 3-10d TOP CHORD (0.131"X 3")nails. Strongbacks to be attached to 1-1P CHO/0,10-11=-2173/0,1-2=-2017/0, walls at their outer ends or restrained by other means. -1=-968/ , 0-11=443/0,4-5=-5443/0, 9)Hanger(s)or other connection device(s)shall be 2-3=-014/0,6-7=7014/0,7-5=-5 43/0 provided sufficient to support concentrated load(s) 8-9=-7053/0,9-70 70183/0 1853 lb down at 21-2-9 on top chord. The BOT CHORD design/selection of such connection device(s)is the 17-18=0/3937,16-17=017014, responsibility of others. 15-16=0I7014,14-15=0/7014, 13-14=0/7840,12-13=017707,11-12=0/390 LOAD CASE(S) WEBS Standard 5-15=0/313,5-17=-1884/0,3-17=0/1618, 1)Dead+Floor Live(balanced):Lumber 3-18=-2064/0,1-18=0/2109,8-12=-713/0, Increase=1.00,Plate Increase=1.00 9-1 2=1 82310,10-12=017354, Uniform Loads(plf) 7-14=1221/0 Vert:11-19=-9,1-10=-51 NOTES- Concentrated Loads(lb) 1)2-ply truss to be connected together with 10d Vert:9=-1828(F) (0.131"x3")nails as follows: Top chords connected as follows:2x8-2 rows staggered at 0-9-0 oc,2x4-1 row at 0-2-0 oc. Bottom chords connected as follows:2x4-1 row at 0-9-0 oc. Julius Lee;P.E. #34869 Webs connected as follows:2x4-1 row at 0-9-0 oc. 110.9 Coastal Bay Boynton Beach,.FL 33435 Job Truss Truss Type Qty Hly A0357919 58824 F19 Floor 1 1 7JobRfrnce(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 2014:35:26 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH-OvgpN2E9V7CdgR2r 6QecXOfdTPKZ6cvJDYVE2z4NKF 0-3-8 2-6-4 2 � 2i Sta le le=1:35.8 1.5x4 II 3x6 3x3= 1.5x4 II 3x4= 1.5x4 II 3x4= 3x4= 3x6 FP= 1.5x4 II 3x6= 4x6= 1 2 3 4 5 6 7 8 9 10 11 12 13 22 21 20 19 18 17 16 15 14 4x8= 3x6 FP=3x6= 1.5x4 11 1.5x4 11 3x6= 4x6=3x3 11 Or3T8 10-8-4 11-8-4,12-8 4, - 20-11-8 0-3-8 10-4-12 1-0-0 1-0-0 8-3-4 Plate Offsets(X Y)- [2:Edoe 0-3-01 [7:0-1-8 Edge] [8:0-1-8,Edge1 [16:0-1-12,Edgel LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.51 Vert(LL) -0.33 18-19 >752 480 MT20 2441190 TCDL 15.0 Lumber Increase 1.00 BC 0.89 Vert(TL) -0.64 18-19 >388 360 BCLL 0.0 Rep Stress Incr YES WB 0.61 Horz(TL) -0.01 14 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:107 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP M 30(flat) - 5)Provide mechanical connection(by others)of truss BOT CHORD 2x,4 SP M 30(flat) to bearing plate atjoint(s)1. WEBS 2x4 SP No.3(flat)*Except* 6)"Semi-rigid pitchbreaks with fixed heels"Member W1:2x4 SP No.2(flat) end fixity model was used in the analysis and design BRACING- of this truss. TOP CHORD pa Structural wood sheathing directly applied or 6-0-0 oc 7)Recommend 2x6 strongbacks,on edge,s ced at 10-0-0 oc and fastened to each truss with 3-10d ROT CHORD purT except end verticals. (0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. Rigid ceiling directly applied or 10-0-0 oc bracing. 8)CAUTION,Do not erect truss backwards. REACTIONS. (lb/size) 14 = 903/Mechanical LOAD CASE(S) 1 = 899/0-2-10 (min.0-1-8) Standard FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 13-14=-929/0,2-3=-1939/0,3-4=-1941/0, 4-5=-1941/0,5-6=-3736/0,6-7=-3736/0, 7-8=-3808/0,8-9=-3025/0,9-10=-3025/0, 10-11=-3025/0,11-12=-632/0, 12-13=-632/0 BOT CHORD 20-21=0/3007,19-20=0/3007, 18-19=0/3808,17-18=0/3808, 16-17=0/3808,15-16=0/1874 WEBS 7-19=450/224,6-19=-263/0,5-19=0/806, 5-21=-1 179/0,4-21=-284/0,2-21=0/2123, 8-16=-1020/0,11-16=0/1273, 11-15=-1439/0,13-15=0/1115 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Plate(s)atjoint(s)20 checked for a plus or minus 5 degree rotation about its center. 3)Plate(s)atjoint(s)14,13,9,3,18,7,17,8,6,19,5,4 ,21,2,10,16,11,15 and 12 checked for a plus or Julius Lee;P.E. 934869 minus 0 degree rotation about its center. 1109 Coastal Bay 4)Refer to girder(s)for truss to truss connections. Boynton Beach,.FL 33435 Job NSS russ ype ty y 58824 F20 Floor 1 1 Job Reference(optional) A0357920 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:27 2014 Page 1 ID:YRb6ZZgQrA7iabOq p8wopfz7lH_-t6EBbNFoGRKUlbcl Ypxt9kxkTtjPIXg3YtH3mUz4N KE 0-3-8 0�6i 2-6-0 2�0-0 2-0-0 S le=1:35.3 1.5x4 II 1.5x4 II 4x4� 4x6= 3x4= 1.5x4 11 3x4= '3x4= 3x6 FP=1.5x4 11 3x6= 4x6= 1 2 3 4 5 6 7 8 9 10 11 12 13 N01 it VA 11 23 22 21 20 19 18 17 16 15 14 4x6= 4x6= 3x6 FP=3x6= 1.5x4 11 1.5x4 11 3x6= 4x6=3x3 11 Or318 1-8-8 10-4-14 11-4-1412 4-14, 20-8-1 0-3-8 1-5-0 8-8-6 1-0-0 1-0-6 8-3-4 Plate Offsets(X,Y)- [2:Edge,0-3-131,[7:0-1-8,Edge1 [8:0-1-8,Edge] [16:0-1-12,Edge],[22:0-1-8,Edge] LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.89 Vert(LL) -0.34 18-19 >723 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.90 Vert(TL) -0.66 18-19 >375 360 BCLL 0.0 Rep Stress Incr YES WB 0.74 Horz(TL) -0.02 14 n/a n/a BCDL 10.0 Code FBC201 OITP12007 (Matrix) Weight:108 lb FT=O%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) 4)Refer to girder(s)for truss to truss connections. BOT CHORD 2x4 SP No.2(flat) Except' x4 SP M 30(flat) 5)Provide mechanical connection(by others)of truss B2:2 WEBS 2x4 No. 30at) to bearing plate at joint(s)1. BRACING- 6)"Semi-rigid pitchbreaks with fixed heels"Member TOP CHORD end fixity model was used in the analysis and design Structural wood sheathing directly applied or 2-2-0 oc of this truss. pudins, except end verticals. 7)Recommend 2x6 stongbacks,on edge,spaced at BOT CHORD 10-0-0 cc and fastened to each truss with 3-1 Od Rigid ceiling directly applied or 10-0-0 cc bracing. (0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. REACTIONS. (lb/size) 8)CAUTION,Do not erect truss backwards. 14 = 890/Mechanical 1 . = 887/0-2-10 (min.0-1-8) LOAD CASE(S) FORCES. (lb) Standard Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 13-14=-918/0,2-3=-1219/0,3-4=-1708/0, 4-5=-1708/0,5-6=-3609/0,6-7=-3609/0, 7-8=-3716/0,8-9=2971/0,9-1 0=-2971/0, 10-11=-2971/0,11-12=-623/0, 12-13=-623/0 BOT CHORD 21-22=0/1223,20-21=0/2854, 19-20=0/2854,18-19=0/3716, 17-18=0/3716,16-17=0/3716, 15-16=0/1845 WEBS 7-19=468/191,5-19=0/835,5-21=-1267/0, 3-21=01862,8-16=-981/0,11-1 6=0/1 246, 11-15=-1415/0,1 3-15=0/1 100, 3-22=928/0,2-22=0/1547 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Plate(s)at joint(s)20 checked for a plus or minus 5 degree rotation about its center. 3)Plate(s)atjoint(s)14,13,9,3,18,7,17,8,6,19,5,4 Julius Lee;P.E. #34869 ,21,10,16,11,15,12,22 and 2 checked for a plus or minus 0 degree rotation about its center. 11 y Coastal Bay Boynton Beach,.FL 33435 Job russ I russ Type y y A0357921 58824 F21 G Floor Girder 1 , 2 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20-14:35:27 2014 Page 1 I D:YRb67ZgQrA7iabOgp8wopfz7lH_-t6EBbNFoGRKU Ibci Ypxt9kxgftvZlfQ3YtH3mUz4NKE 0 4 2-0-0 2-3-0 2-3-0 2-10-6 2-10-6 1i Scale=1:34.8 2x4 11 3x4= 1.5x4 11 1.5x4 11 3x4= 2x4 11 5x8= 2x4 11 3x6= 1 2 3 4 5 6 7 8 2 d, 4 6 d 17 16 15 14 12 10 4x6= 3x4= 3x4= 3x4= 4x12= 1.5x4 11 4x12= 1.5x4 II 4-11-5 5-11-5 6-11-5 12-0-4 12 0-6 15-4-2 18-7-14 18 8-0 20-7-14 4-11-5 1-0-0 1-0-0 5-0-15 0- -2 3-3-12 3-3-12 0- -2 1-11-14 Plate Offsets(X Y)— 17:0-4-0,0-3-01,[17:0-2-4,0-2-01 LOADING(psf) SPACING- 14-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.49 Vert(LL) -0.02 16 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.19• Vert(TL) -0.04 16 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.25 Horz(TL) 0.01 13 n/a n/a BCDL 10.0 Code FBC20101TP12007 (Matrix-M) Weight:196 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 NOTES- BOT CHORD 2x4 SP No.2 1)2-ply truss to be connected together with 1 Od WEBS 2x4 SP No.3*Except* (0.131"x3")nails as follows: W1:2x8 SP No.2,W7:2x6 SP No.2 Top chords connected as follows:2x8-2 rows BRACING-TOP CHORD staggered at 0-9-0 cc,2x6-2.rows staggered at 0-9-0 cc,2x4-1 row at 0-2-0 cc. Structural wood sheathing directly applied or 6-0-0 cc Bottom chords connected as follows:2x4-1 row at purlins, except end verticals. 0-9-0 oc. ROT CHORD Rigid ceiling directly applied or 6-0-0 cc bracing. Webs connected as follows:2x4-1 row at 0-9-0 cc,2x8-2 rows staggered at 0-9-0 cc. REACTIONS. (lb/size) 2)All loads are considered equally applied to all plies, 17 = 448/Mechanical except if noted as front(F)or back(B)face in the 11 = 1849/0-3-8 (min.0-1-8) LOAD CASE(S)section.Ply to ply connections have 13 = 1175/0-3-8 (min.0-1-8) been provided to distribute only loads noted as(F)or (B),unless otherwise indicated. Max Grav 454(LC 5) 3)Unbalanced floor live loads have been considered 17 11 = 191 (LC(LC for this design. 13 = 1188(LC 3) 4)Plates checked for a plus or minus 0 degree rotation about its center. FORCES. (lb) 5)Refer to girder(s)for truss to truss connections. Max.Comp./Max.Ten.-All forces 250(lb)or less 6)"Semi-rigid pitchbreaks with fixed heels"Member except when shown. end fixity model was used in the analysis and design TOP CHORD of this truss. - 2-3=-CHOR,3 4=1081/0,4-5=-1081/0, 7)Recommend 2x6 strongbacks,on edge,spaced at 5-3=-10836,6-18=0/736,6-7=0/736, 10-0-0 cc and fastened to each truss with 3-1 Od 7-8=00 736,6-9=0/1993 (0.131"X 3")nails. Strongbacks to be attached to BOT CHORD walls at their outer ends or restrained by other means. BOO C01775,15-16=0/1081,14-15=0/538, 8)CAUTION,Do not erect truss backwards. 13-14=0/538,12-13=/1081,, 9)Hanger(s)or other connection device(s)shall be 11-12=04538,0 provided sufficient to support concentrated load(s) 570 lb down at 11-6-2,and 1212 lb down at 20-5-2 WEBS WEBS712/0,8-11=-335/0,2-16=0/379, on top chord. The design/selection of such 2-17=789/0,5-15=0/622,5-13=1344/0, connection device(s)is the responsibility of others. 7-13=0/672,9-11=-2202/0,7-11=-1114/0 LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plo Vert:10-17=-13,1-9=-73 Julius Leer P.E. #34869 Concentrated Loads(lb) 1;109 Coastal Bay Vert:9=-1212(B)18=-516(F) Boynton Beach,FL 33435 Job I toss I cuss I ype Qt y ply A0357922 58824 F22 Floor 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MTek Industries,Inc Fri Jun 20 14:35:28 2014 Pagge�1 ID:YRb6ZZgQrA7iabOgp8wopfz71H=LlnZojFQIkSLviBE5XS6hyT12HA114mCnXlcJwz4NKD 0-3-8 15� i 1i� 2-0-0 2-6-0 1-6-9 Scale=1:18.9 3x4 3x3 11 3x3= 1.5x4 11 1.5x4 11 3x4= 3x3 11 1 2 3 4 5 6 7 8 0 l 13 12 11 10 9 3x6= 3x3= 3x4= 3x6= -3- 4-8-7 5-8 7 6-8-7 11-1-9 3- 4-4-15 1-0-0 1-0.0 4-5-1 Plate Offsets(X,Y)— [2:Edge,0-2-41,[10:0-1-8,Edge1 LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.32 Vert(LL) -0.07 11-12 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.48 Vert(TL) -0.14 9-10 >974 360 BCLL 0.0 Rep Stress Incr YES WB 0.37 Horz(TL) 0.01 9 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix) Weight:58 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) LOAD CASE(S) BRACING- Standard TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 9 = 477/Mechanical 1 = 473/0-2-10 (min.0-1-8) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-616/0,3-4=-617/0,4-5=1071/0, 5-6=-1071/0,6-7=1071/0 BOT CHORD 11-12=0/895,10-11=0/1071,9-10=0/571 WEBS 2-12=0/781,4-12=-363/0,7-10=0/554, 7-9=-704/0,4-11=0/325 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)Refer to girder(s)for truss to truss connections. 4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)1. 5)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131"X Tj nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. Jullus.Lee;P.E. #34869 7)CAUTION,Do not erect truss backwards. 1709 Coastal Bay Boynton Beach,.FL 33435 o } f Job I russ I runs Type Qty ply A0357923 58824 F23 Floor 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:28 2014 Page 1 ID:YRb6ZZgQrA7iabOgpBwopf771H=LlnZojFQ1kSLvIBE5XS6hyTlZHBxl4xCnXlcJwz4NKD 0-3-8 1-5-0 1, 1�13 2-0-0 2-6-0 1-6-9 tale=1:18.4 3x4 3x3 11 3x3= 1.5x4 11 1.5x4 11 3x4= 3x3 11 1 2 3 4 5 6 7 8 Ti CT 4 13 12 11 103x4= 9 3x6= 3x3= 3x6= 3- 4-5-1 5-5-1 6-5-1 10-10-2 -3- 4-1-9 1-0-0 1-0-0 4-5-1 Plate Offsets(X,Y)— [2:Edge,0-2-41,[10:0-1-8 Edgel LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.35 Vert(LL) -0.06 9-10 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.44 Vert(TL) -0.14 9-10 >907 360 BCLL 0.0 Rep Stress Incr YES WB 0.36 Horz(TL) 0.01 9 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:57 lb FT=O%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) LOAD CASE(S) BRACING- Standard TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 9 = 465/Mechanical 1 = 461/0-2-10 (min.0-1-8) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-598/0,3-4=-599/0,4-5=1019/0, 5-6=-1019/0,6-7=1019/0 BOT CHORD 11-12=0/840,10-11=0/1019,9-10=0/554 WEBS 2-12=01758,4-12=-329/0,7-10=0/517, 7-9=-684/0,4-11=0/332 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)Refer to girder(s)for truss to truss connections. 4)Provide mechanical connection(by others)of truss to bearing plate atjoint(s)1. 5)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. Julius Lee;P.E. 934869 7)CAUTION,Do not erect truss backwards. 1:109 Coastal Bay Boynton Beach,fl-33435 Job I russ I cuss Type City Ply A0357924 58824 F24G FLOOR GIRDER 1 2 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:28 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=LlnZojFQIkSLvIBE5XS6hyTOVH54lxOCnXlcJwz4NKD 1-9-10 1-7-14 2-0-0 2-7-5 2-7-5 Scale=1:25.2 1.5x4 11 1.5x4 I I 5x8= 1 4x8= 2 4x6= 3 3x4= 4 5 4x4= 6 7 W2 W 5 1 01 Li Li 5 a, 14 a' 13 12 11 10 9 8 3x4 11 3x6= 4x6= 3x4= 15-1-11 1.5x4 11 6x10= 2x4 II -0-8-7, 1-10-15 3-10 4 11-1-11 14-4-6 14r6-0 rt&7 1-10-15 1-11-6 7-3-7 3-2-11 0- -10 Plate Offsets(X,Y)-- [2:0-2-8,0-2-01,[3:0-1-12,0-1-81,[7:0-4-0,0-2-01,[9:0-3-8,0-2-81,rl1:0-1-12,0-1-81,fl2:0-2-8,0-2-01,rl3:0-1-12,0-1-81 LOADING(psf) SPACING- 14-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.42 Vert(LL) -0.16 10-11 >999 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.81 Vert(TL) -0.47 10-11 >368 360 BCLL 0.0 Rep Stress Incr NO WB 0.91 Horz(TL) -0.07 14 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:143 lb FT=0% LUMBER- TOP CHORD 2x4 SP M 31 2)All loads are considered equally applied to all plies, BOT CHORD 2x4 SP M 31 except if noted as front(F)or back(B)face in the WEBS 2x4 SP No.3*Except* LOAD CASE(S)section.Ply to ply connections have Concentrated Loads(lb) W2:2x8 SP No.2,W5:2x4 SP M 30 been provided to distribute only loads noted as(F)or Vert:6=-235(F) W1:2x4 SP No.2 4)2nd chase Dead+Floor Live(unbalanced):Lumber 3) BRACING- unless otherwise indicated. Increase=1.00,Plate Increase=1.00 TOP CHORD 3)Unbalanced floor live loads have been considered Uniform Loads(plo Structural wood sheathing directly applied or 4-6-15 cc for this design.4)Plates checked for a plus or minus 0 degree Vert:8-14=-13,1-4=-227,4-15=-403,7-15=-383 purlins, except end verticals. rotation about its center. Concentrated Loads(lb) BOT CHORD ro ro Load case(s)1,2,3,4,5,6 has/have been Vert:6=-61 O(F) Rigid ceiling directly applied or 10-0-0 cc bracing. modified.Building designer must review loads to 5)3rd chase Dead:Lumber Increase=1.00,Plate verify that they are correct for the intended use of this Increase Uniform LoadLoad 1.00 REACTIONS. (lb/size) s(plf) 14 = 3156/0-8-0 (min.0-1-8) truss. Vert:8-14=13,1-5=-403,5-15=-227,7-15=-207 8 = 3486/0-3-8 (min.0-1-8) 6)"Semi-rigid pitchbreaks with fixed heels"Member Concentrated Loads(lb) end fixity model was used in the analysis and design Vert:6=-235(F) FORCES. (lb) of this truss. 6)4th chase Dead:Lumber Increase=1.00,Plate Max.Comp./Max.Ten.-All forces 250(lb)or less 7)Recommend 2x6 strongbacks,on edge,spaced at Increase=1.00 10-0-0 cc and fastened to each truss with 3-10d except when shown. Uniform Loads(plf) (0.131"X 3")nails. Strongbacks to be attached to TOP CHORD Vert:8-14=-13,14=-227,4-15=403,7-15=-383 walls at their outer ends or restrained by other means. 1-14=3007/0,1-2=-5669l0,2-3=-9030/0, Concentrated Loads(lb) 3-4=-11060/0,4-5=-11060/0,5-6=8431/0, 8)Hanger(s)or other connection device(s)shall be Vert:6=-61 O(F) 6-15=-8431/0,7-15=-8431/0 provided sufficient to support concentrated load(s) BOT CHORD 610 lb down at 11-4-11 on top chord. The 13-14=0/383,12-13=0/5669,11-12=019030, design/selection of such connection device(s)is the 1 0-1 1=0/1 1 06 0,9-10=0111060 responsibility of others. WEBS 7-8=-3404/0,4-11=-953/0,6-9=-2001/0, LOAD CASE(S) 7-9=0/8906,5-9=-3343/0,2-13=2557/0, 1)Dead+Floor Live(balanced):Lumber 3-12=1783/0,1-13=0/5826,2-12=0/3813, Increase=1.00,Plate Increase=1.00 3-11=0/2801 Uniform Loads(plf) NOTES- Vert:8-14=-13,1-15=403,7-15=-330 1)2-ply truss to be connected together with 1Od Concentrated Loads(lb) (0.131"x3")nails as follows: Vert:6=-610(F) Top chords connected as follows:2x8-2 rows 2)Dead:Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) staggered at 0-9-0 cc,2x4-1 row at 0-7-0 cc. Bottom chords connected as follows:2x4-1 row at Vert:en14=ed 1 Loads (lb03,7-15=-330 0-9-0 cc. Concentrated Loads(lb) Vert:6=-61 Webs connected as follows:2x8-2 rows staggered at 3)1st chase Dead+Floor Live(unbalanced):Lumber 0-9-0 cc,2x4-1 row at 0-9-0 cc. Increase=1.00,Plate Increase=1.00 Julius Lee;P.E. #34869 Uniform Loads(plf) 1109 Coastal Bay Vert:8-14=-13,1-5=-403,5-15=-227,7-15=-207 Boynton Beach,FL 33435 Job Truss russ Type ty y 58824 F25G Floor Girder 1 1 Job Reference(optional) A0357925 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:28 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopf27lH_LlnZojFQIkSLvISE5XS6hyTvvHCcl76CnX1cJwz4NKD 1-5-0 1 3x3 11 2 3x3= 3 3x3 11 Scale=1:8.7 Ci W1 W1 W1 W1 3x6= 5 4 3x6= 0 3 0 3-4-0 --- -' 00 O 1 3-1-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.84 Vert(LL) 0.00 5 -- 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.33 Vert(TL) -0.04 4-5 >836 360 BCLL 0.0 Rep Stress Incr NO WB 0.16 Horz(TL) 0.00 4 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:22 lb FT=0%F,0%E LUMBER- TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) Standard BRACING- 1)Dead+Floor Live(balanced):Lumber TOP CHORD Increase=1.00,Plate Increase=1.00 Structural wood sheathing directly applied or 3-4-0 oc Uniform Loads(plf) purlins, except end verticals. Vert:4-5=-20,1-3=110 BOT CHORD Concentrated Loads(lb) Rigid ceiling directly applied or 10-0-0 oc bracing. Vert:6=-403(F)7=-391(F) REACTIONS. (lb/size) 5 = 590/Mechanical 4 = 606/Mechanical FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. BOT CHORD 4-5=0/516 WEBS 2-4=-656/0,2-5=-656/0 NOTES- 1)Plates checked for a plus or minus 0 degree rotation about its center. 2)Refer to girder(s)for truss to truss connections. 3)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)403 lb down at 1-0-8,and 391 lb down at 2-4-8 on top chord. The design/selection of such connection device(s)is the responsibility of others. 6)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Jullus.Lee;P.E. #34869 Standard 1.109 Coastal Bay Boynton Beach,FL 33435 Job Truss cuss I ype Qty ply A0357926 58824 F26G Floor Girder 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:29 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=pULyO3G2n2aCXvmQfEzLE908ZgXEmXFMOBm9rNz4NKC 3x611 1-3-8 3x611 3x611 1 2 3 Scale=1:8.7 W1 W1 2 W2 W1 W1 61 3x6= 5 4 3x6= 3-1-0 3-1-0 LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.59 Vert(LL) 0.00 5 "" 480 MT20 244/190 TCDL 15.0 Lumber Increase 1.00 BC 0.43 Vert(TL) -0.02 4-5 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.36 Horz(TL) 0.01 4 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:24 lb FT=0%F,O%E LUMBER- TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) LOAD CASE(S) BRACING- Standard TOP CHORD 1)Dead+Floor Live(balanced):Lumber Structural wood sheathing directly applied or 3-1-0 oc Increase=1.00,Plate Increase=1.00 purlins, except end verticals. Uniform Loads(plf) BOT CHORD Vert:4-5=-13,1-3=-473(F=-400) Rigid ceiling directly applied or 10-0-0 oc bracing. Concentrated Loads(lb) Vert:2=-842(F)6=-854(F) REACTIONS. (lb/size) 5 = 1863/Mechanical 4 = 1211/Mechanical FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-5=-897/0 BOT CHORD 4-5=0/1170 WEBS 2-4=-1505/0,2-5=1505/0 NOTES- 1)Plates checked for a plus or minus 0 degree rotation about its center. 2)Refer to girder(s)for truss to truss connections. 3)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131"X V1 nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)854 lb down at 0-5-9,and 842 lb down at 1-9-9 on top chord. The design/selection of such connection device(s)is the responsibility of others. 6)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). Julius Lee;P.E. 934869 1109 Coastal Bay Boynton Beach,FL 33435 Job Truss Truss yp tty Hly A0357927 58824 HJ5 Diagonal Hip Girder 2 - 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:29 2014 Pagge�1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=pULy03G2n2aCXvmQfEzLE90ARgazmcNMOBm9rNz4NKC 1-7-12 3-8-10 7-0-2 1-7-12 2-0-14 3-3-8 Scale:3/4"=1' 4.24 F12 T1 2 1 W1 131 4' 2x4= 0 3x8 11 5 1-2-2 7-0-2 1-2-2 5-10-0 Plate Offsets(X,Y)— (5:0-1-10,0-1-101 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (Ice) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.47 Vert(LL) 0.03 4-5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.19 Vert(TL) -0.05 4-5 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.03 Horz(TL) -0.01 3 n/a n/a BCDL 10.0 Code FBC20101TPI2007 (Matrix-M) Weight:23 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 NOTES- BOT CHORD 2x4 SP No.2 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) WEBS 2x8 SP No.2 Standard Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; BRACING- Concentrated Loads(lb) TOP CHORD Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope); Vert:2=118(F=78,B=40)9=58(F=10,B=49) Structural wood sheathing directly applied or 6-0-0 oc cantilever left and right exposed;end vertical left 10=11(F=-17.B=28) purlins. exposed;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree BOT CHORD rotation about its center. Rigid ceiling directly applied or 10-0-0 oc bracing. 3)This truss has been designed fora 10.0 psf bottom MiTek recommends that Stabilizers and required chord live load nonconcurrent with any other live cross bracing be installed during truss erection,in loads. accordance with Stabilizer Installation guide. 4)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a REACTIONS. (lb/size) rectangle 3-6-0 tall by 2-0-0 wide will fit between the 3 = 174/Mechanical bottom chord and any other members. . 4 = 45/Mechanical 5)Refer to girder(s)for truss to truss connections. 5 = 357/0-11-5 (min.0-1-8) 6)Provide mechanical connection(by others)of truss Max Horz to bearing plate capable of withstanding 100 lb uplift 5 = 165(LC 4) atjoint(s)except at--lb)3=135,5=171. Max Uplift 7)"Semi-rigid pitchbreaks with fixed heels"Member 3 = -135(LC 8) end fixity model was used in the analysis and design 5 = -171(LC 4) of this truss. Max Grav 8)Hanger(s)or other connection device(s)shall be 3 = 174(LC 1) provided sufficient to support concentrated load(s)58 4 = 75(LC 3) lb down and 78 lb up at 1-4-9,49 lb down and 54 lb 5 = 357(LC 1) up at 1-4-9,and 10 lb down and 92 lb up at 4-2-8, and 17 lb down and 85 lb up at 4-2-8 on top chord, FORCES. (lb) and 17 lb down and 36 lb up at 4-2-8,and 39 lb up at Max.Comp./Max.Ten.-All forces 250(lb)or less 4-2-8 on bottom chord. The design/selection of such except when shown. connection device(s)is the responsibility of others. TOP CHORD 9)Warning:Additional permanent and stability 1-2=-139/287 bracing for truss system(not part of this component BOT CHORD design)is always required. 1-5=-342/162 10)In the LOAD CASE(S)section,loads applied to WEBS the face of the truss are noted as front(F)or back(B). 2-5=-363/277 LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Julius Lee;P.E. 934869 Uniform Loads(plf) 1109 Coastal Bay Vert:1-3=-90,4-6=-20 Boynton Beach,FL 33435 t Job NSS NSS Fype Qty Ply A0357928 58824 HJ7 Diagonal Hip Girder 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc Fri Jun 20 14:35:29 2014 Page 1 I D:YRb6ZZgQrA7iabOq pBwopfz7lH--pU LyO3G2n2aCXvmQfEzLE90ABgX7mZC MOB m9rNz4N KC 6-8-10 9-10-1 6-8-10 -3-1-7 Scale=1:18.8 2.12 F12 [r' 3x4= 2 T1 � d 3x4= ab W1 �{ 1 rl B1 d 3x4= o• 6 5 6 1.5x4 II 3x4=4 1-2-2 1-6- 6-8-10 9-10-1 1-2-2 -3-14 5-2-10 3-1-7 Plate Offsets(X Y)— [1:0-9-5 0-0-31 [1:0-3-0,Edge] LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.49 Vert(LL) -0.03 6 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.44 Vert(TL) -0.06 6 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.23 Horz(TL) -0.02 3 n/a n/a BCDL 10.0 Code FBC20101TPI2007 (Matrix-M) Weight:35 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 NOTES- BOT CHORD 2x4 SP No.2. 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) WEBS 2x4 SP No.3 Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Standard BRACING- 1)Dead+Roof Live(balanced):Lumber Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope); TOP CHORD Increase=1.25,Plate Increase=1.25 end vertical left right exposed; Structural wood sheathing directly applied or 5-9-6 oc cantilever left and rig Uniform Loads(pif) purlins. exposed;Lumber DOL=1.60 plate grip DOL=1.60 Vert:1-3=-90,4-7=-20 BOT CHORD 2)Plates checked for a plus or minus 0 degree Concentrated Loads(lb) Rigid ceiling directly applied or 9-1-10 oc bracing. rotation about its center. Vert:11=117(F=66,B=51)12=41(F=10,B=32) 3)This truss has been designed for a 10.0 psf bottom 13=-70(F=-43,13=27)14=35(F=-3,B=38) MiTek recommends that Stabilizers and required chord live load nonconcurrent with any other live cross bracing be installed during truss erection,in loads. 15=-4(F=-17,B=13)16=-42(F=-32,B=-10) accordance with Stabilizer Installation guide. 4)•This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a REACTIONS. (lb/size) rectangle 3-6-0 tall by 2-0-0 wide will fit between the 1 = 488/0-7-12 (min.0-1-8) bottom chord and any other members. 3 = 126/Mechanical 5)Refer to girder(s)for truss to truss connections. 5 = 387/Mechanical 6)Provide mechanical connection(by others)of truss Max Horz to bearing plate capable of withstanding 100 lb uplift 1 = 116(LC 4) at joint(s)3 except at=lb)1=193,5=152. Max Uplift 7)"Semi-rigid pitchbreaks with fixed heels"Member 1 = -193(LC 4) end fixity model was used in the analysis and design 3 = -84(LC 4) of this truss. 5 = -152(LC 4) 8)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)60 FORCES. (lb) lb down and 66 lb up at 2-1-0,73 lb down and 80 lb Max.Comp./Max.Ten.-All forces 250(lb)or less up at 2-1-0,10 lb down and 92 lb up at 4-10-15,20 except when shown. lb down and 83 lb up at 4-10-15,and 43 lb down and TOP CHORD 138 lb up at 7-8-14,and 27 lb down and 132 lb up at 1-1 1=859/409,11-12=-865/413, 7-8-14 on top chord,and 3 lb down and 46 lb up at 2-12=-828/392 2-1-0,43 lb up at 2-1-0,17 lb down and 36 lb up at BOT CHORD 4-10-15,21 lb up at 4-10-15,and 32 lb down and 6 lb 1-7=-385/819,1-14=-410/819, up at 7-8-14,and 15 lb down and 10 lb up at 7-8-14 14-15=-410/819,6-15=410/819, on bottom chord. The design/selection of such 6-16=-410/819,5-16=-410/819 connection device(s)is the responsibility of others. WEBS 9)Warning:Additional permanent and stability 2-5=-884/443 bracing for truss system(not part of this component design)is always required. 10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). Julius.Lee;F.E. #34869 LOAD CASE(S) 1109 CoasMI Bay Standard Boynton Beach,FL'33435 o cuss I cuss Type Qty Ply A0 557929 58824 HJ7A Diagonal Hip Girder 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:30 2014 Page 1 ID:YRb6ZZgOrA7iabOgp8wopfz7lH=HhvKDPHgYMi393LcDyVanNZL54t4V1PVErWjjNpz4NKB 5-9-14 8-11-8 5-9-14 3-1-10 Scale=1:16.7 2.33 F12 3x4= 2 T1 3x4= W1 W2 1 B1 3x4= A a 6 5 1.5x4 11 3x4= 4 1-1-6 1 6 6, 5-1-3 8-11-8 �+0-51 3-6-13 3-10-5 Plate Offsets(X,Y)— [1:0-8-8 0-0-31,[1:0-2-e,Edgel LOADING(psn SPACING- 2-0-0 CSI. DEFL. in (Ice) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.48 Vert(LL) -0.02 6 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.39 Vert(TL) -0.05 5-6 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.17 Horz(TL) -0.01 3 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:33 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 2)Plates checked for a plus or minus 0 degree BOT CHORD 2x4 SP No.2 rotation about its center. WEBS 2x4 SP No.3 BRACING- 3)This truss has been designed fora 10.0 psf bottom TOP CHORD chord live load nonconcurrent with any other live loads Structural wood sheathing directly applied or 6-0-0 cc . purlins. 4) This truss has been designed for a live load of BOT CHORD 20.Opsf on the bottom chord in all areas where a Rigid ceiling directly applied or 10-0-0 cc bracing. rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. MiTek recommends that Stabilizers and required 5)Refer to girder(s)for truss to truss connections. cross bracing be installed during truss erection,in 6)Provide mechanical connection(by others)of truss accordance with Stabilizer Installation uide. to bearing plate capable of withstanding 100 lb uplift atjoint(s)except(jt=lb)1=232,3=107,5=118. REACTIONS. (lb/size) 7)"Semi-rigid pitchbreaks with fixed heels"Member 1 = 544/0-10-0 (min.0-1-8) end fixity model was used in the analysis and design 3 = 150/Mechanical of this truss. 5 = 296/Mechanical 8)Hanger(s)or other connection device(s)shall be Max Horz provided sufficient to support concentrated load(s)12 1 = 116(LC 4) lb down and 81 lb up at 4-5-13,24 lb down and 91 lb Max Uplift up at 4-8-13,and 38 lb down and 131 lb up at 7-0-11 1 = -232(LC 4) ,and 34 lb down and 150 lb up at 7-10-15 on top 3 = -107(LC 4) chord,and 19 lb up at 4-5-13,24 lb up at 4-8-13, 5 = -118(LC 4) and 20 lb down and 8 lb up at 7-0-11,and 20 lb down and 11 lb up at 7-10-15 on bottom chord. The FORCES. (lb) design/selection of such connection device(s)is the Max.Comp./Max.Ten.-All forces 250(lb)or less responsibility of others. except when shown. 9)Warning:Additional permanent and stability TOP CHORD bracing for truss system(not part of this component 1-11=664/305,2-11=-602/280 design)is always required. BOT CHORD 10)In the LOAD CASE(S)section,loads applied to 1-7=-277/610,1-14=-327/610, the face of the truss are noted as front(F)'or back(B). 6-14=327/610,6-15=-327/610, 15-16=-327/610,5-16=327/610 WEBS LOAD CASE(S) 2-5=-653/351 Standard 1)Dead+Roof Live(balanced):Lumber NOTES- Increase=1.25,Plate Increase=1.25 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Uniform Loads(pin Vasd=128mph;TCDL=5.Opsf;BCDL=S.Opsf;h=20ft; Vert:1-3=-90,4-7=20 Cat.II;Exp D;End.,GCpi=0.18;MWFRS(envelope); Concentrated Loads(lb) cantilever left and right exposed;end vertical left Vert:11=60(F=37,B=22)12=-38(B)13=-34(F) Julius Lee;P.E. 934869 exposed;Lumber DOL=1.60 plate grip DOL=1.60 14=28(F=14,B=14)15=-11(B)16=-13(F) .1:109 CoastatBay Boynton Beachr.FL 33435 Job I rvss cuss I ype Qty ply ' A0357930 58824 HJA Diagonal Hip Girder 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:30 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH-HhvKDPHgYMi393LcDyVanNZOt4xW2DVErWjjNpz4NKB 1 6-3 5-7-12 8-1-14 1-6-3 4-1-8 2-6-2 Scale=1:19.4 3x4 4.66 F12 3 T1 2x4 II W2 2 OH8 1 Li B1 Lj ri• 7 6 2x4= 6' o• 1.5x4 11 8 5 2x4 11 3x4= 1-0-14 1-6-3, 5-7-12 8-0-5 8-,1-it 4 1-0-14 6-5-5 4-1-8 2-4-9 01119 Plate Offsets(X,Y)— I6:Edge,0-1-81 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.30 Vert(LL) 0.01 7-8 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.17 Vert(TL) -0.01 7 >999 240 BCLL 0.0 ' Rep Stress Incr NO W3 0.12 Horz(TL) -0.01 4 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:34 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 NOTES- BOT CHORD 2x4 SP No.2 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) WEBS 2x4 SP No.3*Except Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Standard W1:2x8 SP No.2 Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope); Vert:14=-90,5-9=-2 BRACING- cantilever left and right exposed;end vertical left Concentrated Loads(lb) TOP CHORD exposed;porch left exposed;Lumber DOL=1.60 plate Vert:12=23(B)13=31(F)14=-37(B)15=16(B) Structural wood sheathing directly applied or 6-0-0 oc grip DOL=1.60 16=15(F)17=-10(B) purtins. 2)Plates checked for a plus or minus 0 degree BOT CHORD rotation about its center. Rigid ceiling directly applied or 10-0-0 cc bracing. 3)This truss has been designed for a 10.0 psf bottom MiTek recommends that Stabilizers and required chord live load nonconcurrent with any other live cross bracing be installed during truss erection,in loads. accordance with Stabilizer Installation guide. 4)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a REACTIONS. (lb/size) rectangle 3-6-0 tall by 2-0-0 wide will,fit between the 4 = 100/Mechanical bottom chord and any other members. 6 = 258/Mechanical 5)Refer to girder(s)for truss to truss connections. 8 = 498/0-10-10 (min.0-1-8) 6)Provide mechanical connection(by others)of truss Max Horz to bearing plate capable of withstanding 100 lb uplift 8 = 211(LC 8) at joint(s)4 except(jt=lb)6=315,8=384. Max Uplift 7)"Semi-rigid pitchbreaks with fixed heels"Member 4 = -82(LC 8) end fixity model was used in the analysis and design 6 = -315(LC 5) of this truss. 8 = -384(LC 4) 8)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)98 FORCES. (lb) lb up at 4-5-3,and 116 lb up at 5-0-11,and 37 lb Max.Comp./Max.Ten.-All forces 250(lb)or less down and 156 lb up at 7-0-1 on top chord,and 13 lb except when shown. down and 58 lb up at 4-5-3,and 15 lb down and 73 lb TOP CHORD up at 5-0-11,and 20 lb down and 95 lb up at 7-0-1 2-12=321/258 on bottom chord. The design/selection of such BOT CHORD connection device(s)is the responsibility of others. 1-8=-271/118,8-15=291/236, 9)Warning:Additional permanent and stability 15-16=-291/236,7-16=2911236, bracing for truss system(not part of this component 7-17=291/236,6-17=-291/236 design)is always required. WEBS 10)In the LOAD CASE(S)section,loads applied to 3-6=-323/399,2-8=-397/278 the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Jullus.Leei P.E. #34869 Increase=1.25,Plate Increase=1.25 1109 Coastal Bay Uniform Loads(plf) Boynton Beach,FL 33435 o Job I russ cuss Type ty y A0357931 58824 HJB Diagonal Hip Girder 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s Meyy 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:31 2014 Pa e 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH-ItTiRIIIJfgwmCwpnfOpJaScHUJfEWJeTVFGvFz4NIU 1-11-13 � 1-11-13 Scale=1:6.0 2.60 12 i i c5 1 d 0 T1 d, d 81 X o 3x4= Q' �o �o Qo 1-8-15 1-11-13 1-8-15 0-2-14 Plate Offsets(X Y)— [1:0-6-11 0-0-41 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.07 Vert(LL) -0.00 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.05 Vert(TL) -0.00 4 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 1 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix-M) Weight:6 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4)`This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 1-11-13 oc 5)Refer to girder(s)for truss to truss connections. purlins. 6)Provide mechanical connection(by others)of truss BOT CHORD to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 10-0-0 oc bracing. at joint(s)3,2,1. MiTek recommends that Stabilizers and required 7)."Semi-rigid pitchbreaks with fixed heels"Member cross bracing be installed during truss erection,in end fixity model was used in the analysis and design accordance with Stabilizer Installation ui(e. of this truss. 8)Warning:Additional permanent and stability REACTIONS. (lb/size) bracing for truss system(not part of this component 3 = -9/Mechanical design)is always required. 2 = 12/Mechanical 1 = 214/0-9-4 (min.0-1-8) Max Horz LOAD CASE(S) 1 = 29(LC 8) Standard Max Uplift 3 = -9(LC 1) 2 = -14(LC 8) 1 = -85(LC 8) Max Grav 3 = 6(LC 8) 2 = 12(LC 1) 1 = 214(LC 1) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Extedor(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation. about its center. Julius Lee;P.E.#34869. 3)This truss has been designed for a 10.0 psf bottom 1:109 Coastal Bay chord live load nonconcurrent with any other live loads. Boynton Beach,EL'33435 � a Job ss I russ Type Qty y A0357932 58824 HJC Diagonal Hip Girder 2 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:31 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_ItTiRIIIJfgwmCwpnfOpJa5bJUlcEWJeTVFGvFz4NKA 2-10-13 r 2-10-13' Scale=1:6.8 2.52 F12 i ci � d 1 T1 `7_ d d B1 3x4= Q° 1-0-4 1-5-1 2-10-13 1-0-4 0 4 13 1-5-12 Plate Offsets(X,Y)-- [1:0-7-7 0-0-31 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.13 Vert(LL) 0.01 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.12 Vert(TL) -0.01 4 >999 240 BCLL 0.0 * Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:9 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 3)Plates checked for a plus or minus 0 degree BOT CHORD 2x4 SP No.2 rotation about its center. BRACING- 4)Gable studs spaced at 2-0-0 cc. TOP CHORD 5)This truss has been designed for a 10.0 psf bottom Structural wood sheathing directly applied or 2-10-13 cc chord live load nonconcurrent with any other live pudins. loads. Rigid BOTOceilliing directly applied or 10-0-0 cc bracing.HORD 6)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a MiTek recommends that Stabilizers and required rectangle 3-6-0 tall by 2-0-0 wide will fit between the cross bracing be installed during truss erection,in bottom chord and any other members. accordance with Stabilizer Installation guide. 7)Refer to girder(s)for truss to truss connections. 8)Provide mechanical connection(by others)of truss REACTIONS. (lb/size) to bearing plate capable of withstanding 100 lb uplift 1 = 286/0-9-9 (min.0-1-8) atjoint(s)2,3 except(jt=lb)1=116. 2 = 49/Mechanical 9)"Semi-rigid pitchbreaks with fixed heels"Member 3 = -24/Mechanical end fixity model was used in the analysis and design Max Horz of this truss. 1 = 40(LC 8) 10)Waming:Additional permanent and stability Max Uplift bracing for truss system(not part of this component 1 = -116(LC 8) design)is always required. 2 = -38(LC 8) 3 = -24(LC 1) Max Grav LOAD CASE(S) 1 = 286(LC 1) Standard 2 = 49(LC 1) 3 = 20(LC 8) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Extedor(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the Julius Lee;P.E. 934869 face),see Standard Industry Gable End Details as 1109 Coastal Bay applicable,or consult qualified building designer as per Boynton Beach,.FL'33435 Job russ I russ I.ype Qty ply A0357933 58824 HJD JACK-CLOSED GIRDER 1 . 2 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s Meyy 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:32 2014 Page 1 I D:YR b6ZZg Q rA7iabO gp8wo pfz71H_-D314e5lw4zzn O MV?KNX3soe bOu RQzmdoi9?q Siz4 NK9 215 8-8-8 14-11-0 21-1-2 2 4-5 6-4-3 6-2-8 6-2-2 Scale=1:35.8 1.22 12 2x4 II 3x4-4x4- II 6 3.00 F12 3x4 4 5 44 Sx = 3 0 d N 1 T vVVz d e e 11 10 9 8 4x4= 7 3x4% 4x6 II 4x4= 3x6= 19-1 11 2 4 5 , 8-8-8 14-11-0 21-1-2 0-10-8' 1-5-13 ' 6-4-3 6-2-8 6-2-2 Plate Offsets(X,Y)- [1:0-5-0,0-0-61,[2:0-2-8,0-6-01 LOADING(psf) SPACING- 1-4-0 CSI. DEFL. in (ice) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.84 Vert(LL) 0.32 10 >779 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.91 Vert(TL) -0.53 8-10 >476 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.89 Horz(TL) 0.07 7 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:195 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 NOTES- 10)Hanger(s)or other connection device(s)shall be BOT CHORD 2x4 No.2'Except' 1)2-ply truss to be connected together with 12d provided sufficient to support concentrated load(s)39 62:2xx 4 SP M 30 (0.131"x3.25")nails as follows: lb down and 103 lb up at 2-4-5,39 lb down and 103 WEBS 2x4 SP No.3 Top chords connected as follows:2x4-1 row at 0-9-0 lb up at 2-4-5,12 lb down and 70 lb up at 4-8-12,12 BRACING- oc clinched. lb down and 70 lb up at 4-8-12,40 lb down and 92 lb TOP CHORD Bottom chords connected as follows:2x4-1 row at up at 6-11-0,40 lb down and 92 lb up at 6-11-0,66 Structural woad sheathing directly applied or 3-10-9 oc 0-9-0 oc clinched. lb down and 114 lb up at 9-1-5,66 lb down and 114 ROT CHORD purT except end verticals. Webs connected as follows:2x4-1 row at 0-9-0 oc lb up at 9-1-5,91 lb down and 135 lb up at 11-3-9, clinched. 91 lb down and 135 lb up at 11-3-9,116 lb down and Rigid ceiling directly applied or 6-10-6 oc bracing. 2)All loads are considered equally applied to all plies, 156 lb up at 13-5-14,116 lb down and 156 lb up at REACTIONS. (lb/size) except if noted as front(F)or back(B)face in the 13-5-14,31 lb down and 84 lb up at 15-8-2,31 lb 1 = 1244/0-8-0 (min.0-1-8) LOAD CASE(S)section.Ply to ply connections have down and 84 lb up at 15-8-2,13 lb down and 70 lb up 7 = 2395/Mechanical been provided to distribute only loads noted as(F)or at 17-10-6,13 lb down and 70 lb up at 17-10-6,and Max Horz (B),unless otherwise indicated. 64 lb down and 107 lb up at 20-0-11,and 58 lb down 1 = 112(LC 4) 3)Wind:ASCE 7-10;Vult=165mph(3-second gust) and 109 lb up at 20-0-11 on top chord,and 45 lb up Max Uplift Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; at 2-4-5,45 lb up at 2-4-5,25 lb up at 2-6-7,25 lb = 839(LC 7) Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope); up at 2-6-7,0 lb down and 8 lb up at 4-8-12,0 lb 1 1 = 136(L C 7) cantilever left and right exposed;end vertical left down and 8 lb up at 4-8-12,19 lb down and 3 lb up at exposed;Lumber DOL=1.60 plate grip DOL=1.60 6-11-0,19 lb down and 3 lb up at 6-11-0,35 lb down FORCES. (lb) 4)Plates checked for a plus or minus 0 degree at 9-1-5,35 lb down at 9-1-5,51 lb down at 11-3-9, Max.Comp./Max.Ten.-All forces 250(lb)or less rotation about its center. 51 lb down at 11-3-9,66 lb down at 13-5-14,66 lb except when shown. 5)This truss has been designed for a 10.0 psf bottom down at 13-5-14,196 lb down and 118 lb up at TOP CHORD chord live load nonconcurrent with any other live 15-8-2,196 lb down and 118 lb up at 15-8-2,250 lb 1-2=-2354/1750,2-22=6246/3573, loads. down and 153 lb up at 17-10-6,250 Ito down and 153 22-23=-6226/3559,3-23=-6201/3549, 6)*This truss has been designed for a live load of lb up at 17-10-6,and 162 lb down and 84 lb up at 3-24=5001/2820,24-25=-4985/2802, 20.Opsf on the bottom chord in all areas where a 20-0-11,and 248 lb down and 142 lb up at 20-0-11 25-26=-4954/2775,4-26=-4917/2748, rectangle 3-6-0 tall by 2-0-0 wide will fit between the on bottom chord. The design/selection of such 4-5=-4912/2750 bottom chord and any other members. connection device(s)is the responsibility of others. BOT CHORD 7)Refer to girder(s)for truss to truss connections. 11)Warning:Additional permanent and stability 1-14=-1649/2217,1-1=-1649/2217, 8)Provide mechanical connection(by others)of truss bracing for truss system(not part of this component 1-11=-1673/2217,11-15=-1620/2136, to bearing plate capable of withstanding 100 lb uplift design)is always required. 15-16=-1620/2136,10-16=-1620/2136, atjoint(s)except at=lb)1=839,7=1369. 9-10=-3562/6194,9-17=-3562/6194, 9)"Semi-rigid pitchbreaks with fixed heels"Member 17-18=-3562/6194,8-18=-3562/6194, end fixity model was used in the analysis and design LOAD CASE(S) 8-19=-2777/4930,19-20=-2777/4930, of this truss. Standard 20-21=-2777/4930,7-21=-2777/4930 1)Dead+Roof Live(balanced):Lumber WEBS Increase=1.25,Plate Increase=1.25 2-11=-354/233,2-10=-2123/4078, Uniform Loads(plo 3-10=359/376,3-8=-1291/801, Vert:1-2=-60,1-7=-13,2-6=60 5-8=-506/1204,5-7=-4971/2794 Concentrated*Loads(lb) Julius Lee;P.E. 934869 1:109 Coastal Bay Continued on page 2 Boynton Beach,FL`33435 Job I russ cuss I ype QtY Ply A0357933 58824 HJD JACK-CLOSED GIRDER 1 2 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:32 2014 Page 2 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_D314e5lw4zznOMV?KNX3soebOuRQzmdoi9?gSiz4NK9 LOAD CASE(S) Standard Concentrated Loads(lb) Vert:2=131(F=66,B=66)9=-35(F=-18,B=-18) 11=89(F=44,B=44)15=10(F=5,B=5)16=-15(F=-7, 13=7)17=-54(F=-27,B=27)1 8=-71(F=-36,B=-36) 19=-392(F=-196,B=-196)20=-499(F=-250,B=-250) 21=410(F=162,B=-248)22=25(F=-12,B=-12) 23=79(F=-40,B=40)24=-1 31(F=-66,B=-66) 25=-182(F=91,B=-91)26=-231(F=-116,B=-116) 27=-61(F=-31,B=-31)28=-26(F=-13,13=13) 29=-121(F=64,B=58) Julius Lee;P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ I cuss Type Qty y ' 58824 J5 Jack-Open 2 1 Job Reference(optional) A0357934 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 2614:35:32 2014 Page 1 ID:YRb6ZZgOrA7iabOgpBwopfz7lH_D314e5lw4zznOMV?KNX3soeiMua6zzZoi9?gSiz4NK9 5-0-0 5-0-0 Scale=1:15.8 6.00 F12 T1 L N N 3x8 II �{ 1 1 RJ 131 3x4= A 0-10-8 5-0-0 0 4-1-8 — Plate Offsets(X Y)— [1:0-1-4 0-0-2] [1'0-1-0 1-0-51 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.43 Vert(LL) -0.03 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.36 Vert(TL) -0.03 4 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.02 2 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:18lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 NOTES- BOT CHORD 2x4 SP No.2 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) WEDGE Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Left:2x6 SP No.2 Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) BRACING- and C-C Exterior(2)zone;cantilever left and right TOP CHORD exposed;end vertical left exposed;C-C for members. Structural wood sheathing directly applied or 5-0-0 oc and forces&MWFRS for reactions shown;Lumber purlins. DOL=1.60 plate grip DOL=1.60 BOT CHORD 2)Plates checked for a plus or minus 0 degree Rigid ceiling directly applied or 10-0-0 oc bracing. rotation about its center. MiTek recommends that Stabilizers and required 3)This truss has been designed for a 10.0 psf bottom cross bracing be installed during truss erection,in chord live load nonconcurrent with any other live accordance with Stabilizer Installation quide. loads. 4)'This truss has been designed for a live load of REACTIONS. (lb/size) 20.Opsf on the bottom chord in all areas where a 2 = 144/Mechanical rectangle 3-6-0 tall by 2-0-0 wide will fit between the 3 = 30/Mechanical bottom chord and any other members. 1 = 369/0-8-0 (min.0-1-8) 5)Refer to girder(s)for truss to truss connections. Max Horz 6)Provide mechanical connection(by others)of truss 1 = 165(LC 12) to bearing plate capable of withstanding 100 lb uplift Max Uplift atjoint(s)except at=lb)2=123,1=11S. 2 = -123(LC 12) 7)"Semi-rigid pitchbreaks with fixed heels"Member 1 = -118(LC 12) end fixity model was used in the analysis and design Max Grav of this truss. 2 = 144(LC 1) 8)Warning:Additional permanent and stability 3 = 61(LC 3) bracing for truss system(not part of this component 1 = 369(LC 1) design)is always required. FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less LOAD CASE(S) except when shown. Standard TOP CHORD 1-2=-158/340 BOT CHORD 1-7=-569/269,1-4=-129/357 Julius Lee;P.E. #34.869 1,109 Coastal Bay Boynton Beach.,'FL 33435 k Job Truss I cuss I ype Qty Fly A0357935 58824 J7 Jack-Open 7 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc Fri Jun 2014:35:33 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_hFbSrRJYrH5dOW4Bu42107Bn8luiiQpxwpkN_8z4NK8 7-0-0 r 7-0-0 Scale=1:13.2 3.00 F12 T1 1 c� B1 �j 4x4= 0-10 8 7-0-0 0-10-8 6-1-8 Plate Offsets(X Y)— rl:0-5-8,0-0-81 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.81 Vert(LL) -0.05 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.40 Vert(TL) -0.11 3-7 >781 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 2 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:21 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 2)Plates checked for a plus or minus 0 degree BOT CHORD 2x4 SP No.2 rotation about its center. BRACING- 3)This truss has been designed for a 10.0 psf bottom TOP CHORD chord live load nonconcurrent with any other live Structural wood sheathing directly applied or 6-0-0 oc loads. purT BOT CHORD 4)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a Rigid ceiling directly applied or 10-0-0 oc bracing. rectangle 3-6-0 tall by 2-0-0 wide will fit between the MiTek recommends that Stabilizers and required bottom chord and any other members. cross bracing be installed during truss erection,in 5)Refer to girder(s)for truss to truss connections. accordance with Stabilizer Installation auide. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift REACTIONS. (lb/size) at joint(s)except at=lb)1=198,2=146. 1 = 492/0-5-8 (min.0-1-8) 7)"Semi-rigid pitchbreaks with fixed heels"Member 2 = 217/Mechanical end fixity model was used in the analysis and design 3 = 54/Mechanical of this truss. Max Horz 8)Warning:Additional permanent and stability 1 = 116(LC 8) bracing for truss system(not part of this component Max Uplift 198(LC 8) design)is always required. 2 = -146(LC 8) Max Grav LOAD CASE(S) 1 = 492(LC 1) Standard 2 = 217(LC 1) 3 = 97(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-590/610 BOT CHORD 1-7=-724/690 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber Julius Lee;P.E. #34869 DOL=1.60 plate grip DOL=1.60 1109 Coastal.Bay Boynton Beach,'FL 33435 o A0357936 russ Truss ype, ty y 58824 JA Comer Jack 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:33 2014 Page 1 ID:YRb6ZZgQrA7iabOgpBwopfz7lH_-hFbSrRJYrH5dOW4Bu42107Bzq IyoiQpxwpkN_8z4NK8 1-5-9 1-5-9 Scale=1:7.6 6.00 F12 4 d 1 T1 d B1 2x4= 1-5-9 1-5-9 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.06 Vert(LL) 0.00 6 n/r 120 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.14 Vert(TL) -0.00 6 n/r 120 BCLL 0.0 ' Rep Stress]nor YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Cade FBC201 O/TP12007 (Matrix-M) Weight:5 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4)`This truss has been designed.for alive load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 1-5-9 oc 5)Refer to girder(s)for truss to truss connections. BOT CHORD purT 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 6-0-0 oc bracing. at joint(s)3,2. MiTek recommends that Stabilizers and required 7)Non Standard bearing condition. Review required. cross bracing be installed during truss erection,in 8)"Semi-rigid pitchbreaks with fixed heels"Member accordance with Stabilizer Installation ouidp. end fixity model was used in the analysis and design of this truss. REACTIONS. (lb/size) 9)Warning:Additional permanent and stability 3 = 31/Mechanical bracing for truss system(not part of this component 2 = 129/Mechanical design)is always required. Max Horz 3 = -154(LC 1) 2 = 154(LC 1) LOAD CASE(S) Max Uplift Standard 3 = -24(LC 8) 2 = -58(LC 12) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-394/193 BOT CHORD 1-3=-177/409 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Julius Lee;P.E. 934869 fl09 Coastal Bay Boynton Beack.FL 33435 o russ cuss ype ty y Jab Reference(optional) A0357937 58824 JB Comer Jack 1 1 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:33 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=hFbSrRJYrH5dOW4Bu4210?ByplyniQpxwpkN_8z4NK8 1-5-8 1-5-8 Scale=1:7.5 5.87 F12 i N 1 T1 d d E31 2x4= 1-4-0 1-4-0 1- LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (Icc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.06 Vert(LL) 0.00 6 n/r 120 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.14 Vert(TL) -0.00 6 n/r 120 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:5 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4)'This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 1-5-8 oc 5)Refer to girder(s)for truss to truss connections. purlins. 6)Provide mechanical connection(by others)of truss BOT CHORD to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 6-0-0 oc bracing. at joint(s)3,2. MiTek recommends that Stabilizers and required 7)Non Standard bearing condition. Review required. cross bracing be installed during truss erection,in 8)"Semi-rigid pitchbreaks with fixed heels"Member accordance with Stabilizer Installation guide. end fixity model was used in the analysis and design of this truss. REACTIONS. (lb/size) 9)Warning:Additional permanent and stability 3 = 31/Mechanical bracing for truss system(not part of this component 2 = 128/Mechanical design)is always required. Max Horz 3 = -156(LC 1) 2 = 156(LC 1) LOAD CASE(S) Max Uplift Standard 3 = -25(LC 8) 2 = -58(LC 12) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-399/195 BOT CHORD 1-3=-180/413 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Extedor(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Julius.Lee;P.E.#34869. 1:109 Coastal Bay Boynton Beack FL'33435 Q A o russ russ Type ty y A0357938 58824 JC Comer Jack 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 Mi rek Industries,Inc. Fri Jun 20 14:35:33 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH=hFbSrRJYrH5dOW4Bu42107BxLlyLiQpxwpkN_8z4NK8 3-6-1 3-6-1 Scale=1:12.2 5.87 F12 T1 d N N 1 1 B1 2x4= �, 3x8 II 3-6-1 00�0-10-91 2-7-8 Plate Offsets(X Y)-- [1:0-1Plate Offsets Y)-- [1:0-1-5,Edgel[1:0-0-8 1-0-101-0-8 1-0-101 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/de0 L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.16 Vert(LL) -0.00 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.17 Vert(TL) -0.00 4 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight:13 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 2)Plates checked for a plus or minus 0 degree BOT CHORD 2x4 SP No.2 rotation about its center. WEDGE 3)This truss has been designed for a 10.0 psf bottom Left:2x6 SP No.2 chord live load nonconcurrent with any other live BRACING- loads. TOP CHORD 4) This truss has been designed for a live load of Structural wood sheathing directly applied or 3-6-1 oc 20.Opsf on the bottom chord in all areas where a purlins. rectangle 3-6-0 tall by 2-0-0 wide will fit between the BOT CHORD bottom chord and any other members. Rigid ceiling directly applied or 10-0-0 oc bracing. 5)Refer to girder(s)for truss to truss connections. MiTek recommends that Stabilizers and required 6)Provide mechanical connection(by others)of truss cross bracing be installed during truss erection,in to bearing plate capable of withstanding 100 lb uplift accordance with Stabilizer Installation quide. at joint(s)2,3 except Qt=lb)1=171. 7)"Semi-rigid pitchbreaks with fixed heels"Member REACTIONS. (lb/size) end fixity model was used in the analysis and design 2 = 86/Mechanical of this truss. 3 = 6/Mechanical 8)Warning:Additional permanent and stability 1 = 286/0-8-3 (min.0-1-8) bracing for truss system(not part of this component Max Horz design)is always required. 1 = 113(LC 12) Max Uplift 2 = -78(LC 12) LOAD CASE(S) 3 = -33(LC 9) Standard 1 = -171(LC 9) Max Grav 2 = 86(LC 1) 3 = 31(LC 3) 1 = 286(LC 1) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat,11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;porch left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip Julius Lee;P.E. #34869 DOL=1.60 1109 Coastal Bay Boynton Beach,FL 33435 Job Truss I was Type ty y A0357939 58824 JD Comer Jack 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 2014:35:34 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_9S9r9nKBcaDUdgfNSozxxg53hlORs359TUwWaz4NK7 3-11-2 3-11-2 Scale=1:13.3 6.00 12 T1 � N 1 1 B1 2x4= �° 4° 3x8 11 0-1 -8 3-11-2 0-1001 1 3-0-10 Plate Offsets(X,Y)— [1:044 0-0-41,[1:0-0-8 1-0-51 LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.22 Vert(LL) -0.01 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.18 Vert(TL) -0.01 4 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:15 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 NOTES- BOT CHORD 2x4 SP No.2 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) WEDGE Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Left:2x6 SP No.2 Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) BRACING- and C-C Exterior(2)zone;cantilever left and right TOP CHORD exposed;end vertical left exposed;parch left Structural wood sheathing directly applied or 3-11-2 oc exposed;C-C for members and forces&MWFRS for purlins. reactions shown;Lumber DOL=1.60 plate grip BOT CHORD DOL=1.60 Rigid ceiling directly applied or 10-0-0 oc bracing. 2)Plates checked for a plus or minus 0 degree MiTek recommends that Stabilizers and required rotation about its center. cross bracing be installed during truss erection,in 3)This truss has been designed for a 10.0 psf bottom accordance with Stabilizer Installation guide. chord live load nonconcurrent with any other live loads. REACTIONS. (lb/size) 4)"This truss has been designed for a live load of 2 = 103/Mechanical 20.Opsf on the bottom chord in all areas where a 3 = 15/Mechanical rectangle 3-6-0 tall by 2-0-0 wide will fit between the 1 = 307/0-8-0 (min.0-1-8) bottom chord and any other members. Max Horz 5)Refer to girder(s)for truss to truss connections. 1 = 129(LC 12) 6)Provide mechanical connection(by others)of truss Max Uplift to bearing plate capable of withstanding 100 lb uplift 2 = -92(LC 12) at joint(s)2,3 except at--lb)1=182. 3 = -42(LC 9) 7)"Semi-rigid pitchbreaks with fixed heels"Member 1 = -182(LC 9) end fixity model was used in the analysis and design Max Grav of this truss. 2 = 103(LC 1) 8)Warning:Additional permanent and stability 3 = 41(LC 3) bracing for truss system(not part of this component 1 = 307(LC 1) design)is always required. FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(Ib)or less LOAD CASE(S) except when shown. Standard BOT CHORD 14=-101/280 Julius Lee;P.E. #34869 1.109 Coastal Bay Boynton Beach,FL 33435 0 I � Job russ I cuss Type Qty y A0357940 58824 JE Comer Jack 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:34 2014 Page 1 ` ID:YRb67ZgQrA7iabOgp8wopfz7lH_9S9r3nKBcaDUdgfNSoZXxCj?4hEhRs359TUwWaz4NK7 5-6-9 5-6-9 Scale=1:17.1 5.87 F12 N T1 d 6 c5 N 1 1 B1 i 3x4= 4x8 11 0-10-9 5-6-9 0-10-9 4-8-0 Plate Offsets(X,Y)— r1:0-0-9 0-0-01 r1:0-0-12,1-0-21 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.61 Vert(LL) 0.10 3-7 >691 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.41 Vert(TL) 0.09 3-7 >764 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.04 2 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:20 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 NOTES- BOT CHORD 2x4 SP No.2 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) WEDGE Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Left:2x6 SP No.2 Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) BRACING- and C-C Exterior(2)zone;cantilever left and right TOP CHORD exposed;end vertical left exposed;porch left Structural wood sheathing directly applied or 5-6-9 cc exposed;C-C for members and forces&MWFRS for BOT CHORD purT reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 Rigid ceiling directly applied or 10-0-0 cc bracing. 2)Plates checked for a plus or minus 0 degree MiTek recommends that Stabilizers and required rotation about its center. cross bracing be installed during truss erection,in 3)This truss has been designed for a 10.0 psf bottom accordance with Stabilizer Installation quide. chord live load nonconcurrent with any other live loads. REACTIONS. (lb/size) 4) This truss has been designed for a live load of 2 = 164/Mechanical 20.Opsf on the bottom chord in all areas where a 3 = 36/Mechanical rectangle 3-6-0 tall by 2-0-0 wide will fit between the 1 = 403/0-8-3 (min.0-1-8) bottom chord and any other members. Max Harz 5)Refer to girder(s)for truss to truss connections. 1 = 180(LC 12) 6)Provide mechanical connection(by others)of truss Max Uplift to bearing plate capable of withstanding 100 lb uplift 2 = -137(LC 12) at joint(s)3 except Qt=lb)2=137,1=243. 3 = -69(LC 9) 7)"Semi-rigid pitchbreaks with fixed heels"Member 1 = -243(LC 9) end fixity model was used in the analysis and design Max Grav of this truss. 2 = 164(LC 1) 8)Warning:Additional permanent and stability 3 = 71(LC 3) bracing for truss system(not part of this component 1 = 403(LC 1) design)is always required. FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less LOAD CASE(S) except when shown. Standard TOP CHORD 1-2=-221/668 BOT CHORD 1-7=-1021/375,1-4=-139/384 Julius Lee;P.E. 934869 1109 Coastal Bay Boynton B6ach,.FL'33435 b � F � t Job russ I russ Type Qty ply A0357941 58824 JF Jack-Open 3 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:34 2014 Page 1 ID:YRb67ZgQrA7iabOgp8wopfz7lH_9S9r3nKBcaDUdgfNSoZXxCjxkhBhRs359TUwWaz4NK7 6-4-8 r 6-4-8 Scale=1:19.6 6.00 12 T1 N 05 1 1 131 4,A= ° A' S e• 5x8 II 6-4-8 0-10 8 5-6-0 Plate Offsets(X,Y)— [1:0-1-12,0-0-41 [1:0-0-12,0-11-51 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.88 Vert(LL) 0.19 3-7 >391 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.61 Vert(TL) 0.17 3-7 >434 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.06 2 n/a n/a BCDL 10.0 Code FBC2010ITPI2007 (Matrix-M) Weight:22 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 NOTES- BOT CHORD 2x4 SP No.2 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) WEDGE Vasd=128mph;TCDL=5.Opsf,BCDL=5.Opsf;h=20ft; Left:2x6 SP No.2 Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) BRACING- and C-C Exterior(2)zone;cantilever left and right TOP CHORD exposed;end vertical left exposed;porch left Structural wood sheathing directly applied or 2-2-0 oc_ exposed;C-C for members and forces&MWRS for BOT CHORD purT Freactions shown;.Lumber DOL=1.60 plate grip DOL=1.60 Rigid ceiling directly applied or 10-0-0 cc bracing. 2)Plates checked for a plus or minus 0 degree MiTek recommends that Stabilizers and required rotation about its center. cross bracing be installed during truss erection,in 3)This truss has been designed for a 10.0 psf bottom accordance with Stabilizer Installation guide. chord live load nonconcurrent with any other live loads. REACTIONS. (lb/size) 4) This truss has been designed for a live load of 2 = 194/Mechanical 20.Opsf on the bottom chord in all areas where a 3 = 46/Mechanical rectangle 3-6-0 tall by 2-0-0 wide will fit between the 1 = 454/0-8-0 (min.0-1-8) bottom chord and any other members. Max Horz 5)Refer to girder(s)for truss to truss connections. 1 = 211(LC 12) 6)Provide mechanical connection(by others)of truss Max Uplift to bearing plate capable of withstanding 100 lb uplift 2 = -162(LC 12) atjoint(s)3 except at--lb)2=162,1=272. 3 = -82(LC 9) 7)"Semi-rigid pitchbreaks with fixed heels"Member 1 = -272(LC 9) end fixity model was used in the analysis and design Max Grav of this truss. 2 = 194(LC 1) 8)Warning:Additional permanent and stability 3 = 86(LC 3) bracing for truss system(not part of this component 1 = 454(LC 1) design)is always required. FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less LOAD CASE(S) except when shown. Standard TOP CHORD 1-2=408/1141 BOT CHORD 1-7=-1716/667,1-4=-159/441 Julius Lee;P.E. #34869: 1109 Coastal Bay Boynton Beach,FL'33435 4 } a Job I russ I russ I ype y y - A0357942 58824 JFG Jack-Closed Girder 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 Ml•ek Industries,Inc Fri Jun 20 14:35:35 2014 Page 1 ID:YRb6ZZgQrA7iabCgpBwopfz7lH=eeiDG6LpNuLLFgEaOV4mUQGFj5c1AJoEO7DU31z4NK6 0- 5-6-0 1-1 1-10-00 3-8-0 1.5x4 11 Scale=1:20.2 3 6.00 F12 4x6\\ T1 2 W2 1 1 W1 B1 0 0 0 o Q• o. 4 5 2x4 II 4x6 11 2x4 11 1-10-0 5-6-0 1-10-0 3-8-0 Plate Offsets(X Y)— (1:0-3-0 0-2-4] f2:0-2-4 0-1-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.29 Vert(LL) 0.01 4-5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.28 Vert(TL) -0.02 4-5 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.03 Horz(TL) -0.00 1 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:34 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 NOTES- BOT CHORD 2x6 SP No.2 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) WEBS 2x4 SP No.3'Except' Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; W1:2x8 SP No.2 Cat.ll;Exp D;Encl.,GCpi=0.18;MWFRS(envelope); SLIDER cantilever left and right exposed;end vertical left Left 2x6 SP No.2 1-8-9 exposed;porch left exposed;Lumber DOL=1.60 plate BRACING- grip DOL=1.60 TOP CHORD 2)Plates checked for a plus or minus 0 degree Structural woad sheathing directly applied or 5-6-0 oc rotation about its center. purlins, except end verticals. 3)This truss has been designed for a 10.0 psf bottom BOT CHORD chord live load nonconcurrent with any other live Rigid ceiling directly applied or 10-0-0 oc bracing. loads. MiTek recommends that Stabilizers and required 4)'This truss has been designed for a live load of cross bracing be installed during truss erection,in 20.Opsf on the bottom chord in all areas where a accordance with Stabilizer Installation auide. rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. REACTIONS. (lb/size) 5)Refer to girder(s)for truss to truss connections. 1 = -98/0-8-0 (min.0-1-8) 6)Provide mechanical connection(by others)of truss 4 = 288/Mechanical to bearing plate capable of withstanding 100 lb uplift 5 = 792/0-8-0 (min.0-1-8) at joint(s)1 except(jt=lb)4=152,5=487. Max Horz 7)"Semi-rigid pitchbreaks with fixed heels"Member 1 = 179(LC 8) end fixity model was used in the analysis and design Max Uplift of this truss. 1 = -98(LC 1) 8)Hanger(s)or other connection device(s)shall be 4 = -152(LC 8) provided sufficient to support concentrated load(s) 5 = -487(LC 8) 393 lb down and 196 lb up at 3-6-4 on bottom chord. Max Grav The design/selection of such connection device(s)is 1 = 201(LC 8) the responsibility of others. 4 = 288(LC 1) 9)Warning:Additional permanent and stability 5 = 792(LC 1) bracing for truss system(not part of this component design)is always required. FORCES. (lb) 10)In the LOAD CASE(S)section,loads applied to Max.CompdMax.Ten.-All forces 250(lb)or less the face of the truss are noted as front(F)or back(B). except when shown. WEBS 2-5=-327/307 LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(plf) Vert:1-3=-90,4-6=20 Jtlflus,Lee;P.E. #34869' Concentrated Loads(lb) 1109 Coastal Bay Vert:12=-393(F) Boynton Beach,FL 33435 � R Job Truss Truss Type Q y ply A0357943 58824 JH Comer Jack 2 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:35 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_-eeiDG6LpNuLLFgEaOV4mUQGI15f4AJIE07DU31 z4NK6 2-6-1 2-6-1 Scale=1:6.9 3.00 F12 1 fO T1 d u? d Bi 3x4= Al 2x4 II Q° A. 0° 0-10-8 2-6-1 0-10-8 1-7-9 Plate Offsets(X,Y)— [1:0-0-15,0-7-101,[1:0-1-4,Edge1 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.08 Vert(LL) -0.00 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.08 Vert(TL) -0.00 4 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 HOrz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:8 lb FT=0% LUMBER- ' TOP CHORD 2x4 SP No.2 4)'This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 2-6-1 oc 5)Refer to girder(s)for truss to truss connections. purlins. 6)Provide mechanical connection(by others)of truss BOT CHORD to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 10-0-0 oc bracing. atjoint(s)1,2,3. MiTek recommends that Stabilizers and required 7)"Semi-rigid pitchbreaks with fixed heels"Member cross bracing be installed during truss erection,in end fixity model was used in the analysis and design accordance with Stabilizer Installation guide. . of this truss. 8)Warning:Additional permanent and stability REACTIONS. (lb/size) bracing for truss system(not part of this component 1 = 244/0-8-0 (min.0-1-8) design)is always required. 2 = 44/Mechanical 3 = -19/Mechanical Max Horz LOAD CASE(S) 1 = 41(LC 8) Standard Max Uplift 1 = -96(LC 8) 2 = -35(LC 8) 3 = -19(LC 1) Max Grav 1 = 244(LC 1) 2 = 44(LC 1) 3 = 16(LC 8) FORCES. (lb) Max.Camp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=S.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. Jul[us.Lee;P.E. #34869. 3)This truss has been designed for a 10.0 psf bottom 1109 Coastal Bay chord live load nonconcurrent with any other live loads. Boynton Beach,'FL 33438 Job Truss russ Type uty Ply A0357944 58824 JI Comer Jack 2 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:36 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH-6gGbUSMR8CTCt omZCb?OdpSkV IvmYNdnz1 bTz4NK5 3-4-13 3-4-13 Scale:1.5"=l' 3.00 F12 T1 1 81 3x4= �" 2x4 11 Q" Q° 0-10-8 34-13 0-10-8 2-6-5 Plate Offsets(X Y)— [1:0-0-15 0-7-101 11:0-14 Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.15 Vert(LL) -0.00 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.15 Vert(TL) -0.00 4 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix-M) Weight:10 lb FT=0% LUMBER- TOP CHORD. 2x4 SP No.2 4).This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural woad sheathing directly applied or 34-13 oc 5)Refer to girder(s)for truss to truss connections. purlins. 6)Provide mechanical connection(by others)of truss BOT CHORD to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 10-0-0 oc bracing. at joint(s)2 except Qt=lb)1=111. MiTek recommends that Stabilizers and required 7)"Semi-rigid pitchbreaks with fixed heels"Member cross bracing be installed during truss erection,in end fixity model was used in the analysis and design accordance with Stabilizer Installation guide. of this truss. 8)Warning:Additional permanent and stability REACTIONS. (lb/size) bracing for truss system(not part of this component 1 = 279/0-8-0 (min.0-1-8) design)is always required. 2 = 82/Mechanical 3 = 6/Mechanical Max Horz LOAD CASE(S) 1 = 56(LC 8) Standard Max Uplift 1 = -111(LC 8) 2 = -58(LC 8) Max Grav 1 = 279(LC 1) 2 = 82(LC 1) 3 = 29(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom Julius Lee;P.E. #34869: chord live load nonconcurrent with any other live loads. 1:709 Coastal Bay Boynton Beach,FL'33435 Job Truss I russ Type y y A0357945 58824 JK Comer Jack 2 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 2014:35:36 2014 Page 1 ID:YRb6ZZgQrA7iabOgpBwopfz7lH--6gGbUSMR8CTCt—omZCb?OdpQOVz9vmYNdnz1 bTz4NK5 4-3-8 4-3-8 Scale=1:9.0 3.00 F12 T1 Y 1 d B1 3x4= 0� 2x4 II A' 0-10-8 4-3-8 0-10 8 3-5-0 Plate Offsets(X,Y)— [1:0-0-7,0-7-101,[1:0-1-4,Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/de0 L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.26 Vert(LL) -0.00 3-7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.22 Vert(TL) -0.01 3-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC20101TPI2007 (Matrix-M) Weight:13 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4)*This truss has been designed for a live load of BOA CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 4-3-8 cc 5)Refer to girder(s)for truss to,truss connections. purlins. 6)Provide mechanical connection(by others)of truss BOT CHORD to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 10-0-0 cc bracing. at joint(s)2 except Ot=lb)1=131. MiTek recommends that Stabilizers and required 7)"Semi-rigid pitchbreaks with fixed heels"Member cross bracing be installed during truss erection,in end fixity model was used in the analysis and design accordance with Stabilizer Installation quide. of this truss. 8)Warning:Additional permanent and stability REACTIONS. (lb/size) bracing for truss system(not part of this component 1 = 328/0-8-0 (min.0-1-8) design)is always required. 2 = 117/Mechanical 3 = 21/Mechanical Max Horz LOAD CASE(S) 1 = 71(LC 8) Standard Max Uplift 1 = -131(LC 8) 2 = -81(LC 8) Max Grav 1 = 328(LC 1) 2 = 117(LC 1) 3 = 48(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom Jul[us Lee;P.E. #34869 chord live load nonconcurrent with any other live loads. 1109 Coastal Bay Boynton B6ach,FL"33435 Job I toss FrUSS I ype ty y 7946 58824 JM Comer Jack 2 1 Job Reference(optional) A035 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:36 2014 Page 1 I D:YRb6ZZgQrA7iabOgp8wopfz7lH_-6gGbUSMR8CTCt_omZCb70dpOjVyxvmYNdnz1 bTz4NK5 5-2-3 5-2-3 Scale=1:10.0 3.00 F12 T1 1 131 Qo 3x4= � 0-10-8 5-2-3 0-10-8 4-3-11 Plate Offsets(X,Y)— (1:0-5-8,0-0-81 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.41 Vert(LL) -0.01 3-7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.30 Vert(TL) -0.02 3-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:16 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4)'This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 5-2-3 cc 5)Refer to girder(s)for truss to truss connections. ROT CHORD purT 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 10-0-0 oc bracing. at joint(s)except Qt=lb)1=153,2=102. MiTek recommends that Stabilizers and required 7)"Semi-rigid pitchbreaks with fixed heels"Member cross bracing be installed during truss erection,in end fixity model was used in the analysis and design accordance with Stabilizer Installation guide. of this truss. 8)Warning:Additional permanent and stability REACTIONS. (lb/size) bracing for truss system(not part of this component 1 = 381/0-8-0 (min.0-1-8) design)is always required. 2 = 150/Mechanical 3 = 32/Mechanical Max Horz LOAD CASE(S) 1 = 86(LC 8) Standard Max Uplift 1 = -153(LC 8) 2 = -102(LC 8) Max Grav 1 = 381(LC 1) 2 = 150(LC 1) 3 = 64(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantileverjeft and right exposed;end vertical left exposed;C-C for members and farces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom Julius Lee;P.E. 934869. chord live load nonconcurrent with any other live loads. 1109 Coastal Bay Boynton Be9ch,FL 33435 Job cuss russ Type y y A0357947 58824 �JIN Comer Jack 2 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Ina Fri Jun 20 14:35:36 2014 Page 1 ID:YRb6ZZgOrA7iabOgpBwopfz7lH_6gGbUSMRBCTCt—omZCb?OdpLrVxjvmYNdnz1 bTz4NK5 6-0-14 6-0-14 Scale:V=V 0 3.00 12 d T1 d 1 131 qq �° 4x4= �° 0-10-8 6-0-14 0-1 0-8 5-2-6 Plate Offsets(X,Y)— [1:0-5-8,0-0-0) LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.59 Vert(LL) -0.03 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.38 Vert(TL) -0.05 3-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 2 n/a n/a BCDL 10.0 Code FBC20101TP12007 (Matrix-M) Weight:18 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 2)Plates checked for a plus or minus 0 degree BOT CHORD 2x4 SP No.2 rotation about its center. BRACING- 3)This truss has been designed for a 10.0 psf bottom TOP CHORD chard live load nonconcurrent with any other live Structural wood sheathing directly applied or 6-0-0 oc loads. purlins. 4)•This truss has been designed for a live load of BOT CHORD 20.Opsf on the bottom chord in all areas where a Rigid ceiling directly applied or 10-0-0 oc bracing. rectangle 3-6-0 tall by 2-0-0 wide will fit between the MiTek recommends that Stabilizers and required bottom chord and any other members. cross bracing be installed during truss erection,in 5)Refer to girder(s)for truss to truss connections. accordance with Stabilizer Installation guide. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift REACTIONS. (lb/size) atjoint(s)except at=lb)1=175,2=124. 1 = 437/0-8-0 (min.0-1-8) 7)"Semi-rigid pitchbreaks with fixed heels"Member 2 = 182/Mechanical end fixity model was used in the analysis and design 3 = 42/Mechanical of this truss. Max Horz 8)Warning:Additional permanent and stability 1 = 101(LC 8) bracing for truss system(not part of this component Max Uplift design)is always required. 1 = 175(LC 8) 2 = -124(LC 8) Max Grav LOAD CASE(S) 1 = 437(LC 1) Standard 2 = 182(LC 1) 3 = 80(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when.shown. TOP CHORD 1-2=-289/332 BOT CHORD 1-7=405/347 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=S.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS.for reactions shown;Lumber Julius Lee;P.E. #34869 DOL=1.60 plate grip DOL=1.60 1109 Coastal Bay Boynton Beach,FL 33435 a � o russ cuss Type y y A0357948 56824 JO Comer Jack 2 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek IndusUies,Inc Fri Jun 20 14:35:37 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH-a1 gzhoM3vVb3U7Ny7w7EZrLTBvFpeDoXrRia7vz4NK4 6-11-9 6-11-9 Scale=1:13.2 3.00 F12 T1 1 B1 4x4— p• 0. 0-10-8 6-11-9 , 0-1 0-8 6-1-1 Plate Offsets(X Y)— 11:0-5-8 0-0-8) LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.81 Vert(LL) -0.04 3-7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.45 Vert(TL) -0.10 3-7 >860 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 HOrz(TL) -0.01 2 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:21 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 2)Plates checked for a plus or minus 0 degree BOT CHORD 2x4 SP No.2 rotation about its center. BRACING- 3)This truss has been designed for a 10.0 psf bottom TOP CHORD chord live load nonconcurrent with any other live Structural wood sheathing directly applied or 6-0-0 oc loads. purlins. 4)`This truss has been designed for a live load of BOT CHORD 20.Opsf on the bottom chord in all areas where a Rigid ceiling directly applied or 10-0-0 oc bracing. rectangle 3-6-0 tall by 2-0-0 wide will fit between the MiTek recommends that Stabilizers and required bottom chord and any other members. cross bracing be installed during truss erection,in 5)Refer to girder(s)for truss to truss connections. accordance with Stabilizer Installation guide. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift REACTIONS. (lb/size) atjoint(s)except Qt=lb)1=198,2=145. 1 = 494/0-8-0 (min.0-1-8) 7)"Semi-rigid pitchbreaks with fixed heels"Member 2 = 214/Mechanical end fixity model was used in the analysis and design 3 = 51/Mechanical of this truss. Max Holz 8)Warning:Additional permanent and stability 1 = 116(LC 8) bracing for truss system(not part of this component Max Uplift design)is always required. 1 = -198(LC 8) 2 = -145(LC 8) Max Grav LOAD CASE(S) 1 = 494(LC 1) Standard 2 = 214(LC 1) 3 = 95(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when,shown. TOP CHORD 1-2=-506/537 BOT CHORD 1-7=-644/598 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.ll;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber Julius Lee;P.E. #34869 DOL=1.60 plate grip DOL=1.60 1109 Coastal Bay Boynton Beach,EL 33435 ( D Job I russ I russ Type y y A0357949 58824 JP Comer Jack 2 Qt 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Ina Fri Jun 20 14:35:37 2014 Page 1 ID:Y.Rb6ZZgQrA7iabOgp8wopfz7lH_al gzhoM3vVb3U7Ny7w7EZrLYovGWeAOXrRia7vz4NK4 4-10-10 7-10-5 4-10-10 2-11-11 Scale=1:15.3 3.00 F12 3x4 2 T1 ti M �N W1 1 B1 El 5 0 3x4 3x4= 4 0-10 8 7-10-5 0-101 6-11-13 Plate Offsets MY)— [1:0-5-8,0-0-4) LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.45 Vert(LL) -0.06 5-9 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.41 Vert(TL) -0.14 5-9 >657 240 BCLL 0.0 Rep Stress Incr YES WB 0.22 Horz(TL) 0.01 3 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight:28 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 2)This truss is not designed to support a ceiling and BOT CHORD 2x4 SP No.2 is not intended for use where aesthetics are a WEBS 2x4 SP No.3 BRACING- consideration. TOP CHORD 3)Plates checked for a plus or minus 0 degree Structural wood sheathing directly applied or 6-0-0 oc rotation about its center. purlins. 4)This truss has been designed for a 10.0 psf bottom BOT CHORD chord live load nonconcurrent with any other live Rigid ceiling directly applied or 7-0-8 oc bracing. loads. 5)'This truss has been designed for a live load of MiTek recommends that Stabilizers and required 20.Opsf on the bottom chord in all areas where a cross bracing be installed during truss erection,in rectangle 3-6-0 tall by 2-0-0 wide will fit between the accordance with Stabilizer Installation guide. bottom chord and any other members. 6)Refer to girder(s)for truss to truss connections. REACTIONS. (lb/size) 7)Provide mechanical connection(by others)of truss 1 = 501/0-8-0 (min.0-1-8) to bearing plate capable of withstanding 100lb uplift 3 = 106/Mechanical at joint(s)3 except at--lb)1=189,5=104. 5 = 253/Mechanica( 8)"Semi-rigid pitchbreaks with fixed heels"Member Max Harz end fixity model was used in the analysis and design 1 = 131(LC 8) of this truss. Max Uplift 9)Warning:Additional permanent and stability 1 = -189(LC 8) bracing for truss system(not part of this component 5 = 104(C LC 88 design)is always required. FORCES. (lb) LOAD CASE(S) Max.Comp./Max.Ten.-All forces 250(lb)or less Standard except when shown. TOP CHORD 1-2=-604/538 BOT CHORD 1-6=-415/520,1-5=-673/590 WEBS 2-5=-642/733 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber Jullus.Lee;P.E. #34869: DOL=1.60 plate grip DOL=1.60 1.109 Coastal Bay Boynton 13each,"FL"33435 Job I russ Truss Type Qty Ply �AO57950 58824 JQ Comer Jack 2 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:37 2014 Page 1 ID:YRb6ZZgQrA7iabOgpSwopfz7lH-al gzhoM3vVb3U7Ny7w7EZrLXSvEgeAFXrRia7vz4NK4 5-10-7 8-9-0 5-10-7 2-10-9 Scale=1:16.9 3.00 F12 3x4= 2 N T1 N N N N W1 1 91 5 3x4=4 4x4= 0-10-8 8-9-0 0-10-8 7-10-8 Plate Offsets(X,Y)— [1:0-5-e,Edge] LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.55 Vert(LL) -0.10 5-9 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.52 Vert(TL) -0.24 5-9 >433 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.23 Horz(TL) -0.01 5 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) .Weight:31 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 2)This truss is not designed to support a ceiling and BOT CHORD 2x4 SP No.2 is not intended for use where aesthetics are a WEBS 2x4 SP No.3 consideration. BRACING- 3)Plates checked for a plus or minus 0 degree TOP CHORD rotation about its center. Structural wood sheathing directly applied or 6-0-0 cc 4)This truss has been designed for a 10.0 psf bottom purlins. chord live load nonconcurrent with any other live BOT CHORD loads. Rigid ceiling directly applied or 6-11-15 cc bracing. 5)*This truss has been designed for a live load of MiTek recommends that Stabilizers and required 20.Opsf on the bottom chord in all areas where a cross bracing be installed during truss erection,in rectangle 3-6-0 tall by 2-0-0 wide will fit between the accordance with Stabilizer Installation guide. bottom chord and any other members. 6)Refer to girder(s)for truss to truss connections. REACTIONS. (lb/size) 7)Provide mechanical connection(by others)of truss 1 = 555/0-8-0 (min.0-1-8) to bearing plate capable of withstanding 100 lb uplift 3 = 83/Mechanical atjoint(s)3 except(jt—lb)1=210,5=139. 5 = 320/Mechanical 8)"Semi-rigid pitchbreaks with fixed heels"Member Max Horz end fixity model was used in the analysis and design 1 = 145(LC 8) of this truss. Max Uplift 9)Warning:Additional permanent and stability 1 = -210(LC 8) bracing for truss system(not part of this component 5 = 139(C LC 8) design)is always required. FORCES. (lb) LOAD CASE(S) Max.Comp./Max.Ten.-All forces 250(lb)or less Standard except when shown. TOP CHORD 1-2=-626/533 BOT CHORD 1-9=0/273,1-6=-396/530,1-5=-676/605 WEBS 2-5=-685/766 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=S.Opsf;h=20ft; Cat.11;Exp D;.Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber Julius Lee;P.E. 934869 DOL=1.60 plate grip DOL=1.60 1109 Coastal Bay Boynton Beach,,FL'33435 ONSS NSS ype ty y A0357951 58824 �JIR Comer Jack 2 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:38 2014 Page 1 ID:YRb6ZZg QrA7iab0 gp8wopfz7l H_-2DOLv8 N hg pjw6Hy9h d eT52uhXJYVN c3g45S8f Lz4 NK3 5-8-4 9-7-11 r 5-8-4 3-11-8 Scale=1:18.5 3.00 FIT 3x4 2 T1 c& 1 N N 1 OI I .{ 1 c� B1 o' e o 3x4=4 4x4= 0-10-8 , 9-7-41 J 0-10 8 8-9-3 Plate Offsets(X Y)— [1:0-5-8 Edgel,[5:0-1-5,0-1-81 LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.58 Vert(LL) -0.15 5-9 >747 360 MT20 244/190 TCDL . 15.0 Lumber Increase 1.25 BC 0.68 Vert(TL) -0.37 5-9 >310 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.32 Horz(TL) -0.01 5 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:35 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 2)This truss is not designed to support a ceiling and BOT CHORD 2x4 SP No.2 is not intended for use where aesthetics are a WEBS 2x4 SP No.3 consideration. BRACING- 3)Plates checked for a plus or minus 0 degree TOP CHORD rotation about its center. Structural wood sheathing directly applied or 6-0-0 oc 4)This truss has been designed for a 10.0 psf bottom purlins. chord live load nonconcurrent with any other live BOT CHORD loads. Rigid ceiling directly applied or 5-11-11 oc bracing. 5)'This truss has been designed for a live load of MiTek recommends that Stabilizers and required 20.Opsf on the bottom chord in all areas where a cross bracing be installed during truss erection,in rectangle 3-6-0 tall by 2-0-0 wide will fit between the accordance with Stabilizer Installation guide. bottom chord and any other members. 6)Refer to girder(s)for truss to truss connections. REACTIONS. (lb/size) 7)Provide mechanical connection(by others)of truss 1 = 600/0-8-0 (min.0-1-8) to bearing plate capable of withstanding 100 lb uplift 3 = 141/Mechanical at joint(s)3 except(jt=1b)1=224,5=127. 5 = 315/Mechanical 8)"Semi-rigid pitchbreaks with fixed heels"Member Max Horz end fixity model was used in the analysis and design 1 = 160(LC 8) of this truss. Max Uplift 9)Warning:Additional permanent and stability 1 = -224(LC 8) bracing for truss system(not part of this component 5 98((C 8LC )) design)is always required. FORCES. (lb) LOAD CASE(S) Max.Comp./Max.Ten.-All forces 250(lb)or less Standard except when shown. TOP CHORD 1-2=-8411734 BOT CHORD 1-9=-10/336,1-6=598/742,1-5=-899/823 WEBS 2-5=-878/959 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber Julius Lee;P.E. #3480 DOL=1.60 plate grip DOL=1.60 1109 Coastal Bap BoyptomBeach,FL'33435 o toss toss Type y ��'y Job Reference(optional) A0357952 58824 JS Comer Jack 1 1 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:38 2014 Page 1 I D:YRb6ZZgQrA7iabOgp8wopfz7lH_-2DOLv8Nhgpjw6Hy9hdeT52ulUJfiNebg45S8fLz4NK3 O 7-9 4-1-8 0-7-9 3-5-15 3.00 12 Scale=1:15.3 I� d 4x4= T1 2 N_ m c6 N N W1 W2 O 8 Ll B1 6 5 1.5x4 11 3x4= 4 4-1-8 4-1-8 Plate Offsets(X,Y)— f2:0-2-0 0-2-41 LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.32 Vert(LL) 0.03 5-6 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.22 Vert(TL) -0.03 5-6 >999 240 BCLL 0.0 * Rep Stress Incr YES WB 0.16 Horz(TL) -0.00 5 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:20 lb FT=0% .LUMBER- TOP CHORD 2x4 SP No.2 3)This truss has been designed for a 10.0 psf bottom BOT CHORD 2x4 SP No.2 chord live load nonconcurrent with any other live WEBS 2x4 SP No.3 loads. BRACING- 4)*This truss has been designed for a live load of TOP CHORD 20.Opsf on the bottom chord in all areas where a Structural wood sheathing directly applied or 4-1-8 cc rectangle 3-6-0 tall by 2-0-0 wide will fit between the ROT CHORD purT except end verticals. bottom chord and any other members. 5)Refer to girder(s)for truss to truss connections. Rigid ceiling directly applied or 7-8-0 cc bracing. 6)Provide mechanical connection(by others)of truss MiTek recommends that Stabilizers and required to bearing plate capable of withstanding 100 lb uplift cross bracing be installed during truss erection,in at joints)1,3,5 except(jt=lb)7=124. accordance with Stabilizer Installation ouide. 7)Non Standard bearing condition. Review required. 8)"Semi-rigid pitchbreaks with fixed heels"Member REACTIONS.All bearings Mechanical. end fixity model was used in the analysis and design (lb)-Max Horz of this truss. 1=368(LC 1),7=368(LC 1) 9)Warning:Additional permanent and stability Max Uplift bracing for truss system(not part of this component All uplift 100 lb or less at joint(s)1, design)is always required. 3,5 except 7=-124(LC 12) Max Grav All reactions 250 lb or less at joint(s) LOAD CASE(S) 1,3,7,5 Standard FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-6=-158/330,1-2=-423/301 BOT CHORD 6-7=-549/519,5-6=-474/467 WEBS 2-5=-508/515 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 Julius Lee;P.E. #34869 2)Plates checked for a plus or minus 0 degree rotation 1109 Coastal Bay about its center. Boynton Beach,FL 33435 4# I Job I russ ruse ype y y A0357953 58824 JT Jack-Open 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 Walk Industries,Inc. Fri Jun 20 14:35:38 2014 Page 1 I D:YRb6ZZgQrA7iabOgp8wopfz71H--2DOLv8Nhgpjw6Hy9hdeT52uj7JbFNcog45S8fLz4NK3 4-7-11 8-5-13 4-7-11 3-10-3 Scale:3/4"=1' 3.00 F,2 3x4 2 T1 W1 OH8 1 B1 r1 3x4=0 4' 3x4= 4 0-10 8 8-5-13 0-8 6-1 7-7-5 Plate Offsets MY)— r1:0-5-8,0-0-4),r5:0-2-12,0-1-8) LOADING(psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/deli Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.48 Vert(LL) -0.09 5-9 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.50 Vert(TL) -0.20 5-9 >500 240 BCLL 0.0 Rep Stress Incr YES WB 0.27 Horz(TL) 0.01 3 n/a n/a BCDL 10.0 Code FBC2010frPI2007 (Matrix-M) Weight:31 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 NOTES- CHORD 2x4 SP No.2 WE 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) WEBS 2x4 SP No.3 Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; BRACING- Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) TOP CHORD and C-C Extedor(2)zone;cantilever left and right Structural wood sheathing directly applied or 6-0-0 cc exposed;end vertical left exposed;C-C for members purT ROT CHORD and forces&MWFRS for reactions shown;Lumber Rigid ceiling directly applied or 6-1-15 cc bracing. DOL=1.60 plate grip DOL=1.602)This truss is not designed to support a ceiling and MiTek recommends that Stabilizers and required is not intended for use where aesthetics are a cross bracing be installed during truss erection,in consideration. accordance with Stabilizer Installation guide. 3)Plates checked for a plus or minus 0 degree rotation about its center. REACTIONS. (lb/size) 4)This truss has been designed for a 10.0 psf bottom 1 = 531/0-8-0 (min.0-1-8) chord live load nonconcurrent with any other live 3 = 147/Mechanical loads. 5 = 250/Mechanical 5)*This truss has been designed for a live load of Max Horz 20.Opsf on the bottom chord in all areas where a 1 = 141(LC 8) rectangle 3-6-0 tall by 2-0-0 wide will fit between the Max Uplift bottom chord and any other members. 1 = -199(LC 8) 6)Refer to girder(s)for truss to truss connections. 3 = -101(LC 8) 7)Provide mechanical connection(by others)of truss 5 = -95(LC 8) to bearing plate capable of withstanding 100 lb uplift FORCES. (lb) a8t joint(s)5 except(jt=lb)1=199,3=101. Max.Comp./Max.Ten.-All forces 250(lb)or less )"Semi-rigid pitchbreaks with fixed heels"Member ( ) end fixity model was used in the analysis and design except when shown, of this truss. TOP CHORD 9)Warning:Additional permanent and stability 1-2=-783/713 bracing for truss system(not part of this component BOT CHORD design)is always required. 1-9=-1 47/307,1-6=-591/698, 1-5=-865/7772 WEBS LOAD CASE(S) 2-5=-808/906 Standard Julius Lee;P.E. 934869 1109 Coastal Bay Boynton Beach,FL"33435 Job I russ I russ Type Qty Ply A0357954 58824 JU Jack-Open 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MTek Industries,Inc. Fri Jun 20 14:35:39 2014 Page 1 ID:YRb6ZZgQrA7iabOgpBwopfz7lH_WPyk6UOJR7mkRXLFL9ieGRnBiwo67IgJIBhCoz4NK2 7-3-15 7-3-15 Scale=1:14.3 to 3.00 F12 T1 N 1 B1 �t Q' 4x4= 0-10-8 7-3-15 � 6-5-7 Plate Offsets(X Y)— [1:0-5-8 0-0-121 LOADING(psfi SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.91 Vert(LL) -0.05 3-7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.48 Vert(TL) -0.12 3-7 >708 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.02 2 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight:22 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 2)Plates checked for a plus or minus 0 degree BOT CHORD 2x4 SP No.2 rotation about its center. BRACING- 3)This truss has been designed for a 10.0 psf bottom TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc chord live load nonconcurrent with any other liveloads. purlins. 4)'This truss has been designed for a live load of BOT CHORD 20.0psf on the bottom chord in all areas where a Rigid ceiling directly applied or 10-0-0 oc bracing. rectangle 3-6-0 tall by 2-0-0 wide will fit between the MiTek recommends that Stabilizers and required bottom chord and any other members. cross bracing be installed during truss erection,in 5)Refer to girder(s)for truss to truss connections. accordance with Stabilizer Installation guide. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift REACTIONS. (lb/size) at joint(s)except Qt=1b)1=208,2=153. 1 = 518/0-8-0 (min.0-1-8) 7)"Semi-rigid pitchbreaks with fixed heels"Member 2 = 227/Mechanical end fixity model was used in the analysis and design 3 = 55/Mechanical of this truss. Max Harz 8)Warning:Additional permanent and stability 1 = 122(LC 8) bracing for truss system(not part of this component Max Uplift design)is always required. 1 = -208(LC 8) 2 = -153(LC 8) Max Grav LOAD CASE(S) 1 = 518(LC 1) Standard 2 = 227(LC 1) 3 = 101(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-609/632 BOT CHORD 1-7=-754f716 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber Julius Lee;P.E. 934869. DOL=1.60 plate grip DOL=1.60 1109 Coastal Bay Boynton Beach,'FL 33435 L Job I russ I russ I ype y y 58824 JV Jack-Open 1 1 Job Reference(optional) A0357955 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 Mrrek Industries,Inc Fri Jun 20 14:35:39 2014 Page 1 I D:YRb6ZZg QrA7ia bOgp8wopfz7lH--W Pyk6UOJ R7m kRXLFL9 ieGRskixl67lgJ IB hCoz4N K2 6-2-2 6-2-2 Scale=1:12.1 3.00 F12 T1 d_ 1 B1 4x4= 0-10-8 6-2-2 0-1 0-8 5-3-10 Plate Offsets(X,Y)— [1:0-5-8,0-0-01 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/de0 Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.61 Vert(LL) -0.03 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.39 Vert(TL) -0.05 3-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 2 n/a n/a BCDL 10.0 Code FBC2010(rP12007 (Matrix-M) Weight:19 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 rotation Plates checked for a plus or minus 0 degree BRACING- rotation about its center. TOP CHORD 3)This truss has been designed for a 10.0 psf bottom Structural wood sheathing directly applied or 6-0-0 oc chord live load nonconcurrent with any other live loads. BOT CHORD 4)"This truss has been designed for a live load of Rigid ceiling directly applied or 10-0-0 cc bracing. 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the MiTek recommends that Stabilizers and required bottom chord and any other members. cross bracing be installed during truss erection,in 5)Refer to girder(s)for truss to truss connections. accordance with Stabilizer Installation auide. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift REACTIONS. (lb/size) atjoint(s)except at=lb)1=178,2=126. 1 = 443/0-8-0 (min.0-1-8) 7)"Semi-rigid pitchbreaks with fixed heels"Member 2 = 186/Mechanical end fixity model was used in the analysis and design 3 = 43/Mechanical of this truss. Max Horz 8)Warning:Additional permanent and stability 1 = 102(LC 8) bracing for truss system(not part of this component Max Uplift 178 LC 8 design)is always required. ( ) 2 = -126(LC 8) Max Grav LOAD CASE(S) 1 = 443(LC 1) Standard 2 = 186(LC 1) 3 = 82(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-311/354 BOT CHORD 1-7=430/373 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber Jullus Lee;P.E. #34869 DOL=1.60 plate grip DOL=1.60 1109 Coastal Bay :Boynton Beach,.FL 33435 � y Job Truss cuss I ype Qty Ply FJobReference(optional) A0357956 58824 Jw Jack-Open 1 1 Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:39 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_wpyk6UOJR7mkRXLFL9ieGRwPizs67lgJIBhCoz4NK2 5-0-4 5-0-4 Scale=1:9.8 3.00 12 T1 1 B1 3x4= �° 0-1 0-8 5-0-4 0-10-8 4-1-12 Plate Offsets MY)— 11:0-5-8,0-0-41 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.38 Vert(LL) -0.01 3-7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.29 Vert(TL) -0.02 3-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:15 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4).This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 5-0-4 cc 5)Refer to girder(s)for truss to truss connections. purlins. 6)Provide mechanical connection(by others)of truss BOT CHORD to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 10-0-0 cc bracing. at joint(s)2 except Qt=lb)1=149. MiTek recommends that Stabilizers and required 7)"Semi-rigid pitchbreaks with fixed heels"Member cross bracing be installed during truss erection,in end fixity model was used in the analysis and design accordance with Stabilizer Installation guide. of this truss. 8)Warning:Additional permanent and stability REACTIONS. (lb/size) bracing for truss system(not part of this component 1 = 37110-8-0 (min.0-1-8) design)is always required. 2 = 144/Mechanical 3 = 30/Mechanical Max Horz LOAD CASE(S) 1 = 83(LC 8) Standard Max Uplift 1 = -149(LC 8) 2 = -98(LC 8) Max Grav 1' = 371(LC 1) 2 = 144(LC 1) 3 = 62(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom Julius Lee;P.E: #34869 chord live load nonconcurrent with any other live loads. 1109 Coastal Bay Boynton Bi ach,.FL 33 e � G a � oruss cuss Type y y A0357957 58824 �jjx Jack-Open 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:40 2014 Page 1 ID:YRb6ZZgQrA7iabOgp6wopfz7lH—-cW6JgPxCQzeLb6Xo2gxATz7u6LfraYzYPxFkEz4NK1 3-10-6 3-10-6 Scale=1:8.5 3.00 F12 C V 0 T1 r^5 1 � B1 3x4= A. 2x4 II Q° 0-10-8 23-10-6 1 0- -8 -11-14 Plate Offsets(X,Y)— [1:0-0-11,0-7-101,[1:0-1-4,Edgel LOADING(psfl SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.20 Vert(LL) -0.00 3-7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.19 Vert(TL) -0.00 3-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight:12 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4)'This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural woad sheathing directly applied or 3-10-6 cc 5)Refer to girder(s)for truss to truss connections. ROT CHORD purT 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 10-0-0 cc bracing. at joint(s)2 except(jt=lb)1=121. MiTek recommends that Stabilizers and required 7)"Semi-rigid pitchbreaks with fixed heels"Member cross bracing be installed during truss erection,in end fixity model was used in the analysis and design accordance with Stabilizer Installation uide. of this truss. 8)Warning:Additional permanent and stability REACTIONS. (lb/size) bracing for truss system(not part of this component 1 = 304/0-8-0 (min.0-1-8) design)is always required. 2 = 100/Mechanical 3 = 14/Mechanical Max Harz LOAD CASE(S) 1 = 64(LC 8) Standard Max Uplift 1 = -121(LC 8) 2 = -70(LC 8) Max Grav 1 = 304(LC 1) 2 = 100(LC 1) 3 = 40(LC 3) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Extedor(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom Julius Lee;F.E. #34869 chord live load nonconcurrent with any other live loads. 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ Truss Type Qty Ply A0357958 58824 JY Jack-Open 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:40 2014 Page 1 ID:YRb6ZZgQrA7iabOgpBwopfz7lH--cW6JgPxCQzeLb6Xo2gxATz9c6M1 raYzYPxFkEz4NK1 2-8-9 2-8-9 Scale=1:7.2 3.00 F12 1 T1 d o i B1 3x4= 0� 2x4 II Q� 0-10-8 2-8-9 0-10-8 1-10-1 Plate Offsets(X,Y)— r1:0-0-15,0-7-101,r1:0-1-4,Edge1 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (Icc) Well Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.09 Vert(LL) -0.00 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.10 Vert(TL) -0.00 4 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010fTPI2007 (Matrix-M) Weight:8 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4) This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 2-8-9 cc 5)Refer to girder(s)for truss to truss connections. purlins. 6)Provide mechanical connection(by others)of truss BOT CHORD to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 10-0-0 cc bracing. at joint(s)1,2,3. MiTek recommends that Stabilizers and required 7)"Semi-rigid pitchbreaks with fixed heels"Member cross bracing be installed during truss erection,in end fixity model was used in the analysis and design accordance with Stabilizer Installation guide. of this truss. 8)Warning:Additional permanent and stability REACTIONS. (lb/size) bracing for truss system(not part of this component 1 = 250/0-8-0 (min.0-1-8) design)is always required. 2 = 53/Mechanical 3 = -11[Mechanical Max Horz .LOAD CASE(S) 1 = 44(LC 8) Standard Max Uplift 1 = -99(LC 8) 2 = -40(LC 8) 3 = -11(LC 1) Max Grav 1 = 250(LC 1) 2 = 53(LC 1) 3 = 15(LC 8) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.11;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. Jul(us.Lee;P.E. 934869: 3)This truss has been designed for a 10.0 psf bottom 1109 Coastal Bay chord live load nonconcurrent with any other live loads. Boynton Beach,'FL 33435 . . v Job I russ I russ Type y y A0357959 58824 Jz Jack-Open 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc. Fri Jun 20 14:35:40 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wapfz7lH--_cW6JgPxC OzeLb6Xo2gxATzAl6N_raYzYPxF kEz4NK1 1-9-9 1-9-9 Scale=1:6.1 3.00 FIT 1 1 T1 B1 o 3x4= 2x4 II AO Qo Qo Qo 1-6-8 1-6-8 Plate Offsets(X,Y)— 11:0-0-15 0-7-101 11:0-14,,Edoel LOADING(psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/defi Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.05 Vert(LL) -0.00 4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.04 Vert(TL) -0.00 4 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(fL) -0.00 1 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:6 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 4) This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 1-9-9 oc 5)Refer to girder(s)for truss to truss connections. purlins. 6)Provide mechanical connection(by others)of truss BOT CHORD to bearing plate capable of withstanding 100 lb uplift Rigid ceiling directly applied or 10-0-0 oc bracing. atjoint(s)1,3,2. MiTek recommends that Stabilizers and required 7)"Semi-rigid pitchbreaks with fixed heels"Member cross bracing be installed during truss erection,in end fixity model was used in the analysis and design accordance with Stabilizer Installation guide. of this truss. 8)Warning:Additional permanent and stability REACTIONS. (lb/size) bracing for truss system(not part of this component 1 = 193/0-8-0 (min.0-1-8) design)is always required. 3 = -8/Mechanical 2 = 12/Mechanical Max Horz LOAD CASE(S) 1 = 30(LC 8) Standard Max Uplift 1 = -74(LC 8) 3 = -8(LC 1) 2 = -15(LC 8) Max Grav 1 = 193(LC 1) 3 = 5(LC 8) 2 = 12(LC 1) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.ll;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. Julius.Lee;P.E. #34869: 3)This truss has been designed for a 10.0 psf bottom 1109 Coastal Bay chord live load nonconcurrent with any other live loads. Boynton Beach,FL 33435 Job Fruss Iruss I ype ty y A0357960 58824 VM2 Valley 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc Fri Jun 20 14:35:41 2014 Page 1 ID:YRb6ZZgQrA7iabOgp8wopfz7lH_So4UXAPazk5VzlhkMmBAjhWKgWIVa1n7m3goGgz4NKO 2-0-0 2-0-0 Scale=1:7.2 6.00 12 1 B1 v d 2x4 I LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.06 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(TL) n/a n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix) Weight:5 lb FT=0% LUMBER- TOP CHORD 2x4 SP No2 5)`This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.Opsf on the bottom chord in all areas where a BRACING- rectangle 3-6-0 tall by 2-0-0 wide will fit between the TOP CHORD bottom chord and any other members. Structural wood sheathing directly applied or 2-0-0 oc 6)Bearing at joint(s)2 considers parallel to grain purlins. value using ANSI/TPI 1 angle to grain formula. BOT CHORD Building designer should verify capacity of bearing Rigid ceiling directly applied or 10-0-0 oc bracing. surface. MiTek recommends that Stabilizers and required 7)Provide mechanical connection(by others)of truss cross bracing be installed during truss erection,in to bearing plate capable of withstanding 100 lb uplift accordance with Stabilizer Installation guide. at joints)1,2. 8)"Semi-rigid pitchbreaks with fixed heels"Member REACTIONS. (lb/size) end fixity model was used in the analysis and design 1 = 75/1-11-8 (min.0-1-8) of this truss. 2 = 62/1-11-8 (min.0-1-8) 9)Warning:Additional permanent and stability 3 = 14/1-11-8 (min.0-1-8) bracing for truss system(not part'of this component Max Horz design)is always required. 1 = 46(LC 12) Max Uplift 1 = -21(LC 12) LOAD CASE(S) 2 = -51(LC 12) Standard Max Grav 1 = 75(LC 1) 2 = 62(LC 1) 3 = 27(LC 3) FORCES. (lb) Max.Camp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)Gable requires continuous bottom chord bearing. 4)This truss has been designed for a 10.0 psf bottom Julius Lee;P.E. 934869' chord live load nonconcurrent with any other live loads. 1109 Coastal Bay Boynton Beach,FL'33435 M ' � r • J `� Job Truss I cuss Type Qty Ply A0357961 58824 VM4 Valley 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946 Run:7.520 s May 8 2014 Pdnt:7.520 s May 8 2014 MiTek Industries,Inc, Fri Jun 20 14:35:41 2014 Page 1 ID:YRb6ZZgQrA71abOgpBwopfz7lH_So4UXAPazk5VzlhkMmBAjhWEeWiiva1n7m3goGgz4NKO 4-0-0 4-0-0 Scale=1:11.8 2 1.5x4 II 6.00 12 W1 1 q B1 d d 3 2x4 1.5x4 11 I LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.39 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.12 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:14 lb FT=0% LUMBER- TOP CHORD 2x4 SP No.2 5)"This truss has been designed for a live load of BOT CHORD 2x4 SP No.2 20.0psf on the bottom chord in all areas where a WEBS 2x4 SP No.3 rectangle 3-6-0 tall by 2-0.0 wide will fit between the BRACING- bottom chord and any other members. TOP CHORD 6)Provide mechanical connection(by others)of truss Structural wood sheathing directly applied or 4-0-0 oc to bearing plate capable of withstanding 100 lb uplift purlins, except end verticals. at joint(s)1 except(jt=1b)3=103. BOT CHORD 7)"Semi-rigid pitchbreaks with fixed heels"Member Rigid ceiling directly applied or 10-0-0 oc bracing. end fixity model was used in the analysis and design MiTek recommends that Stabilizers and required of this truss. cross bracing be installed during truss erection,in 8)Warning:Additional permanent and stability accordance with Stabilizer Installation guide. bracing for truss system(not part of this component REACTIONS. (lb/size) design)is always required. 1 = 177/3-11-8 (min.0-1-8) 3 = 177/3-11-8 (min.0-1-8) LOAD CASE(S) Max Horz Standard 1 = 108(LC 12) Max Uplift 1 = -49(LC 12) 3 = -103(LC 12) FORCES. (lb) Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-200/276 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust) Vasd=128mph;TCDL=5.Opsf;BCDL=5.Opsf;h=20ft; Cat.II;Exp D;Encl.,GCpi=0.18;MWFRS(envelope) and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)Gable requires continuous bottom chord bearing. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Jullus Lee;P.E. #34869 1109 Coastal Bay Boynton Beach,FL'33435 ASK e A4 ItUDF TR JSSES AFLORIDA CORPORATION Important Notes / Please Review Prior to Truss Installation: 1) Trusses are to be handled,installed and braced in accordance with the following standards: ANSI/TIP 1-2007;WTCA 1-1995—"Standard Responsibilities in the Design Process Involving Metal Plate Connected Wood Trusses",and"BCSI 1-03 Guide to Good Practice For Handling, Installing,&Bracing of Metal Plate Connected Wood Trusses"published by WTCA and.Truss Plate Institute. Any of this material can be obtained by contacting A-1 Roof Trusses. Spanish versions are also available. 2) All temporary and permanent bracing design,connection,material,and labor by others. 3) Truss designs are for an individual component,not for a truss system. Reactions and uplifts may vary from building designers calculated loads. The building designer is ultimately responsible for clarifying any discrepancies. 4) If provided by truss manufacturer,any engineered beams provided have been sized using information design guides or software provided by the beam manufacturer. The building designer should verify all loads uplifts,and bearing requirements. Truss manufacturer is not responsible for specifying beams,other than those provided by truss manufacturer. 5) Unless specified,roof trusses are not designed for any additional attic storage loads. 6) On flat surfaces,adequate drainage must be provided to avoid ponding. 7) It is the builder's responsibility to assure there is adequate room for A/C ducts,electrical wiring and plumbing runs to assure they do not interfere with the truss chords. (Roof and floor.) Truss chords and webs cannot be cut. Attic access opening should be located between trusses unless otherwise noted. 8) Unless specified,valley framing design,connection,material and labor to be supplied by the builder. 9) Attached drawings are standard details that cover most installation standards. Structural details provided by the building designer supersede any attached details. 10)Trusses are not designed to carry the chimney,cupola,steeple,or other structures unless specified. Structure should be framed through the trusses to be supported by the foundation. In cases where trusses are designed to carry the structure above all loads and uplifts MUST be verified by building designer. Connection of structure to trusses must be provided by the building designer. 1 1)The specific engineered truss drawings are subject to other terms,conditions,and details on the truss placement plan and/or individual truss design drawings. 12)Trusses are designed to carry ONLY the specified loads on the engineered drawings.Point loads for materials,erection personnel,equipment,whether temporary or permanent,are-not allowed unless specified on sealed engineered drawings. Any questions or comments feel free to contact A-1 Roof Trusses at 772-409-1010. 4451 St.Lucie Blvd.,Fort Pierce,FL 34946 772-409-1010 Office 772-409-1015 Fax www.AItruss.com Name: PU Address: STRUCTURAL Customer., CONNECTORS'O W Company Contact: Number. Hangers e� MIR Ilk. ir To In, IN 10 r U'UP] A_,�d Rao Tl JUS24 1883, 655 750 820 510 4-loci(Header) F1.821.39, 2-lod (Joist) 0510.01, RR 15779 LUS24 670 765 825 490 4-10d(Header) 2-10d(Joht) T2 JUS26 1881, 850 975 1060 1115 4-10d(H sad or) FI.821.4Z 4-10d (Joist) 0510.01, RR 25779 LUS26 865 990 1070 1165 4-10d(Header) 4-I od(Joist) T3 MSH422 1831, 22-loci (Face- Face Max Mailing) FL822.36, 6-10d (Face-Top Max Nailing) 08- 6--lod (Joist-Face Max-Nailing) 0303.06, 6-10d (Joist-Top Max Nailing) RR 25836, 4-lod (Top -Top Max Nailing) 13116-R THA422 2245 2245 2245 6-16d(CarriadMernber-FaceMount) 6-lod(Carried Member-Top Flange) 22-16d(Face-Face Mount) 2-16d(face-Top Flange) 4-16d(rap 4 rap Flange) MA1422 1835 1835 1835 2-10dxl-112or2-lodxl-112(Carried Member) 20-10d or 2-lod(Face) 10d(Top) USP Structural Connectors I�W T4 TH D26 1781. 2485 2855 3060 2170 - - - 18-16d (Face) FL13285.35 12-10d x 1-1/2(Joist) , 06- 0921.05, RR 25843 HTU26 2940 3340 3600 1555 I1-lad x 1-112(Carried Member) 20-lad x 1-112(Carried Member-Max Nailing) 20-16d(Carrying Member) 27-16d(Carrying Member-Max Nailing) T5 THD26-2 1781. 2540 2920 3175 2285 - 18- 16d (Face) FL13285.35 12-10d (Joist) , 06- 0921.05, RR 25843, 13116-R HHUS26 2 2785 3155 3405 1550 - 14-16d(Face) 6-16d(Joist) f{TU26-2 2940 3340 3600 2175 - - 20-lad(Carried Member-Max Nailing) 20-16d(Carrying Member-Max Nailing) T6 THD28 1781, 3865 3965 3965 2330 28-16d (Face) FL13285.35 16- 10d x 1-1/2(Joist) , 06- 0921.05, RR 25843 HTU28 3820 4340 4660 2140 26-lad x 1-112(Carried Member-Max Nailing) 26-16d(Corry(nq Member-Max Nailing) T7 THD28-2 17" 3950 4540 4935 2595 - - - 28- 16d (Face) F1.13285.35 16-10d (Joist) , 06- 0921.05, RR 25843, .13116-R HHUS28-2 4210 4770 5140 2000 22-16d(Face) 8-16d(joist) HTU28-2 3820 4340 4680 3485 - - 26-lad(Carried Member-Max Nalling) 26-16d(Carrying Member-Max Nailing) T8 THD46 17814 2540 2920 3175 2285 - 18- 16d (Face) FL13285.35 12-Iod (Joist) , 06- 0921.05, RR 25843, 13116-R USP Structural Connectors f HHUS46 2790 3I60 3410 J550 14-16d(Face) 6-I6d(Joist) T9 THD48 1781. 3950 4540 4935 2595 28-16d (Face) FL13285.35 16- 10d (Joist) 06- 0921.05, ` RR 25843, 13116-R HHUS48 4210 4770 5140 4^ 00 - - 22-16d(Face) 8-16d(Joist) T10 THDH26-2 1881, 3915 4505 4795 2235 20-I6d (Face) FL821.75, 8- 16d(Joist) 06- 0921.05, RR 25779, 13116-R HGUS26-2 4355 4875 S230 2155 - 20-16d(Face) 8-I6d(Joist) T11 THDH26-3 1881, 3915 4505 4795 2235 20-16d(Face) F1.821.75, 8-Ad (Joist) 06- 0921.05, RR 25779 HGUS26-3 4355 4875 5230 2155 20-16d(Face) a-16d(Joist) T12 THDH28-2 :1881, 6535 7515 $025 2665 - 36-16d (Face) 41.8=77, 10--16d (Joist) RR 25779, ,13116-R HGUS28-2 7460 7460 7460 3235 36-16d(Face) 12-16d(Joist) T13 THD1-128-3 1881. 6770 7785 8025 2665 - - 36-16d (Face) FL821.77, 12- 16d (Joist) +06- 0921.05, RR 25779 HGUS28-3 7460 7460 7460 3235 36.16d(Face) 12-16d(Joist) USP Structural Connectors Name: Address: STRUCTURAL Customer. CONNECTORS' A Wek-CompaWy Contact: Number. Fastener Comparison Table '�s�x=�r5. S i=-:c1:=•ia!r�b.y^v iL:-_ - - s `•pi; ._,s- aS��:-k'i- 'a'+.�+•=i .SQL-.=. Y1v✓^. `r._. �t�^•^ -•-_ ,�';�-cam - .:w' '_J:_..?:,...a.-= -�"•�� :�-.eF—�•-�'''C{•:�::�.-• 'rzy_s.L•:�_•x; ' "'�'� � � ..s�. _ ""^Y;"�= Ftc7:..:s-^a'..-n"��T.= _ _.r_•�. '`_o:�.?T' `�'`cF i'"'••' _.i:,.=.r k 'k�i..-c. r�-.m-�__ .v =re��-,-',�::�r-�c�---�`'•::k=-�==cc:..f �• _• �,� M1- �'• ,tee,-.u,.pu�,. � ,�,•�2.�����:c�`"Ys:s�--,,: -.._. A �^.r.:::2<�a5 .$-�::v^...,J�`r:�a"..R ".-:.;?isrr_re-r'+.._T•-a:�:9-�....r:�A.ruts.'cr`w.._:.'�Fau•�T2u.:��s'�:.'i`s.:xgr��''-,.:�r_ e - ^--c-=- 3.:.�_ :� -'.�.^• r� ._.:.;:�-.%:Ye'w =�• ..•'tee-:•e�.',Aiy a,..•-rK2==`�c,:rc�.a.�. e1.•+�. _a*: ,-•."'._ .�< r..-.. .::...Y ce_b• F-a`��'-�e.� = '.-.�'-`7 -,-K:.<+=ti `."'a'.`•+'^-_._' a.••P-4 x. � '-�--�-- -a.,o,=sl. e••� ?;cK., .`-�i-��"�;--x: � ::trsGi+riuLaFieicL[SP..Stoc[�Tifo< Regcnred Fastenerso =; {8`e eren :N �;s u r-p'Regu�rad!Fastenets<K�yt- � TI JUS24 4-10d(Header) LUS24 4-10d(Header) 2-10d(Joist) 2-10d(Joist) TIO THDH26-2 20-16d(Face) HGUS26-2 20-16d(Face) 8-16d(Joist) 8-16d(Joist) T11 THD H26-3 20-16d(Face) HGUS26-3 20-I6d(Face) 8-16d(Joist) 8-16d(Joist) T12 THD H28-2 36-16d(Face) HGUS28 2 36-16d(Face) 10-16d(Joist) 12-16d(Joist) T13 THDH28-3 36-16d(Face) HGUS283 36-16d(Face) 12-16d(Jaist) 12-I6d(Joist) T2 JUS26 4-10d(Header) LUS26 4-10d(Header) 4-10d(Joist) 4-10d(Joist) T3 MSH422 22-10d(Face-Face Max Nailing) TNA422 6-16d(Carried Member-Face Mount) 6-10d (Face-Top Max Nailing) 6-10d(Carried Member-Top Flange) 6-10d(Joist-Face Max Nailing) 22-16d(Face-Face Mount) 6-lOd(Joist-Top Max Nailing) 2-16d(Face-Top Range) 4-10d (Top-Top Max Naifing) 4-16d(Top-Top Flange) T4 TH026 18-16d(Face) HTU26 11-10d x 1-1 r2(Carried Member) 12-10 d x 1-1 j2(Joist) 20-10d x 1-1/2(Carried Member- Max Nailing) 20-16d(Carrying Member) 20-16d(Carrying Member-Max Nailing) TS THD26-2 18-16d(Face) HHUS26-2 14-16d(Face) 12-10d(Joiso 6-I6d(Joist) T6 THD28 28-16d(Face) HTU29 26-10dx1-12(Carried Member- 16-1od x 1-1/2(Joist) Max Mailing) 26-16d(Carrying Member-Max Nailing) 77 TH029-2 28-16d(Face) HHUS28 2 22-16d(Face) 16-10d(Jaist) 8-16d(Joist) T8 THD46 18-16d(Face) HHUS46 14-I6d(Face) 12-10d(Joist) 6-16d(Id&Q T9 THD48 28-I6d(Face) HHUS48 22-16d(Face) 16-10d(Joist) 8-I6d(Joist) USP Structural Connectors j -^4lhh U s p Address STRUCTURAL Customer: CONNECTORS' A=91 Company Comact: Number. P� • - a- JUS24 (Qty. I) THDH26-2- (Qty.- 1) THDH26-3 (Qty.-1), "y THDH28-2 (Qty. 1) THDH28-3 (Qty.- 1) JUS26 (Qty.'1) Ni Left flangePJ Right sg,,�-� ►�'v flange MSH4422 (Qty.•1) THD26 (Qty: 1) THD26-2 (Qty. 1) � - r a Left :�, Left _ t A _ flange `�c 3 flange '.: ., �fi?a. `_�.�: -xis;''��'✓ Right W ��D Right flange flange THD28 (Qty. 1) THD28-2 ((2 ty.-1) THD46 (Qty. I) USP Structural Connectors! - ; AM06Q c vil■, K , � � Wimp, 5 4 - ��` -fvVD4$ cnnecto% . v3sfg$� 10:13ff W76 JakOper7rvss , f IJ&AFfSzrznoa omionatt All P=Firr SSl:5,FDRTF&':K:=-R.3MB RurC735n5.4m22Z012Ptitr:739Dcdu1222D12MTdrIrbtcSltiS.I=r-ritX11913:165.22t112 page 03ZviM aObR E5�mWbWk0yPs 4-h4d3649EN70SuNA94 I/1'73 I WIN S1A 9.9.11 9 iD 2AI 5.1A 4&1 2 16d 6D 6 TYPICAL HIPJACK CONNECTION 'oe"aft Sce4e-,7:L 7►STBK MAX 55 PSF MAX ROOF LOAD rALr=D 170 MPH EX C H=26 MAX N"'131 A 24 t: 2. 72 N41LM 3s4 NAMED 3 N 12 d 4r n m e5 RAILED T1 r Ile HALM 11 o allcornarjadc j1 ukh 2-15d toe raSsTCIECtyp. r--I 87 u C S 14 is 7 76 1 ! NX11.2) NA1lE) 7 57rh n HAUD 3� 37A NAILED HAMM HAILM 24-str3p 6-10dr 1 S- eaadh end 4-8-1 e 9-10-1 g.1_g , Plate011s_ts (X. : dF0.8 0 i LOADING(Fsf) SPACING 240 CSI AEFL in (loc) Vd.11 Ud PLATES GRIP TCLL 30.0 Plates Increase 1.25 TC 0.71 Vert(LL) -0.03 6 7 >999 350 MT20 2441190 TCDL 15.0 Lumber increase 1.25 BC 0.49 Ved(TL) -0.09 6-7 >999 240 BCLL 0.0• Rep Strom Inc NO we 0.50 Hoe(tt) 0.01 6 nia nia CDL 10.0 Cod=FRC201 MTP12007 (Matrix M) Weight.:lb FT.Oy 613ER BRACING OP CHORD 2x4 SYP ra 38 TOP CHORD Structural mood sheathing directly applied or 6 0-0 oc purlins. BOT CHORD a(4 SP No.2 BOT CHORD Structural vmod sheathing directly applied or B-94 or bracing. VdEBS 2x4 SP No.3 NLTek recommends that Stabilizers and inquired cross bractng be Installed during truss erection.in accordance with Stabilizer Installation Guide. REACTIONS pbrsze) 4-1631raeehanleal,2-6 01101 0-1 S (min.0.1-8).6-362rMedlarical Max Horz2_W8(LC 4) Max UpGlt4--156(LC 4).2.-382(LC 4),6•.-169(LC 8) Max Grav4-219(LC 2),2-734(LC 4 6-212(LC 2) FORCES (b)-Max.Comp!Max.Ten.-All forces 250(Ib)or leas except when shorn. TOP CHORD 2-11.-933i645.11-12--85rv3D7.&12--B45i303 BOTCHORD 214--681/848,14-15-439i848.7-1S.-S39f848.7-16-43WB4&6-16-43?1848 WEBS 3-6-9164,75 NOTES 1)W rtd:ASCE 7 10;170mph(3-second gust)Vasd-132rnph;TCOL-S.Opsf.BCDL-&Ops;h-Mfl;CsL li;Exp C;End.,GCpl-(LiB; MWFP.S(envelope);cantilever left and right exposed;Lumber DOL•1.33 plate grip DOL-1.33 2)This buss is not designed to support a ceiling and is not Intended for use vdrere aesthetics are a=siderallon. 3)Plates checked for a plus or sinus 0 ftree rotation about its center. 4)This truss has been designed fora 10.0 psi bottom chord Eve load nonconcunerd with any other live loads. 5)'This truss has been designed fora five load of 20.Opsfon the bottom chord in ail areas where a rectangle 3-6-0 tall by 2-1}0 wide Wit fit beh,een the bottom chord and any other members. 11111111111., _= N 34869 =_ — 'O C� iL(u STATE OF =�; A%- liftiit111 1109 COASTAL SAY BOYNTON SC,FL 33435 10/20/12 v TYPICAL ALTERNATE BRACING DETAIL TOR EXTERIOR FLAT GIRDER TRUSS 12 G 4 1 2d PITCH TRUSS -24 ' o,o, 4 12d MAX 30" (2'—5") UPLIFT CONNECTION s... s 2X6 #2 SP BOTH FACES �.��`,'`�~'' SEE ROOF TRUSS .,. =*: ,,••,� 24°1 EXTERIOR FLAT .GIRDER SIMPSON H5 ° • STATE OF ,•>'�� 0 N'A�,� 1109 COASTAL BAY BOYNTON BC,FL 33435 10/29/22 - PEBRUARY 14. 2D12 STANDARD PIGGYBACK TRUSS ST•PIGGY-PERP. CONNECTION DETAIL(PERPENDICULAR) OQ ® Iffi-ek lydusVieS CheStmfJeld,MO page 1 of 1 F �1 11 MAX MEAN ROOF HEIGHT=30 FEET ��oQ BUILDING CATEGORY 11 WIND EXPOSURE Bor0 WIND DESIGN PER ASCE 7-98,ASCE 7-02,ASCE 7-05100 MPH(MWFRS) WIND DESIGN PERASCE 7-10129 MPH(MWFRS) Mi7ek industries,Inc. DURATION OF LOAD INCREASE FOR WIND LOADS:1.60 DETAIL IS NOT APPLICABLE FOR TRUSSES TRANSFERING DRAG LOADS(SHEAR TRUSSES ADDITIONAL CONSIDERATIONS BY BUILDING ENGINEERIDESIGNER ARE REQUIRED. THIS DETAIL SHALL BE ONLY USED FOR RESISTING A VERTICAL WIND UPLIFT UP TO i40 LBS rdf mum AT EACH COAINECTION POINT. BUILDING DESIGNER IS RESPONSIBLE FOR THE LOAD EXCEEDINGTHIS LIMITATION AND/OR IN OTHER DIRECTIONS. PIGGY-BACKTRUSS (CROSS-SECTION VIEW) ATTACH PIGGYBACKTRUSS Refer to actual.buss design drawingfot TO BASE TRUSS VfWTH additional piggyback truss urformadon. (2)-16d(0-131"X3-5'j NAILS TOENAILED. N EAR SIDE /FAR SIDE NOTES FOR TRUSS: 1. THIS DErAIL IS VALID FOR ONE-PLY PIGGYBACK TRUSS '; THE CHORD MEMBER OF PIGGYBACK AND BASE TRUSSES ONLY: 2. MUST BE SOUTHERN PINE OR DOUGLAS FIR-LARCH LUMBER: 3. THE SPACING OF PIGGYBACK TRUSSES AND BASE TRUSSES IS 2 FT OR LESS: 4. THE PIGGYBACKTRUSSES SHOULD BE PERPENDICULARTO BASE TRUSSES. 5 PIGGYBACK TRUSS MAY NOT CANTILEVER OVER BASE TRUSS OR HAVE AN OVERHANG WHICH WILL CREATE A HIGHER UPLIFT AT CONNECTING POINT. FLAT TOP CHORD �GENS F'< �� OF BASE TRUSS BASE TRUSS(SIDE VIEW) _ �' — Refer-to actual truss design drawing =-U for additional base tmss information. . ,U,l . STATE OF NOTES FOR TOE-NAIL:- %f S 1.TOE WITHTH DRIVEN AT AN ANGLE OF 30 DEGREES E MEMBER AND STARTED /3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 1109 COASTAL BAY 2.THE END DISTANCE,EDGE DISTANCE,AND SPACING OF BOYNTON BC,FL 33435 NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OFTHE WOOD. FEBRUARY 14.2012 Standard Gable End Detail SHEET 2 , MTek Indushies,CheawfwP—MO Page 2 of 2 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD Trusses ar 247 ox. o� HOP,IZONTAL BRACE 24 DIAG0IAL BRACE SPACED-*r O.C. (SEE SECTION A A) ATTACHED TD VERTICAL WITH(4)-16d WekIndustries,Inc. RoofSheathin� COMMON WIRE NAILS AND ATTCHED TO BLOCKING WITH(5)-tad C=;IONS. Max. TTIS THE RESPONSIBILITY QFTHEBLDG DESIGNER OR A NAIL DIAGONAL BRACETO EPROJECT ENGINEERJARCHTECTTODESGN T HE L I T'NQ16d NAILS CEILING DIAPHRAGMAND TSATTACHMENTTOTHE USSESTO RESISTALL OUT OF PLANE LOADS THAT MAYRESULTFROM THE BRACNr3 OFTHE GABLE ENDS 2X 4 PURLUV FASTENED TO FOUR TRUSSES WTH TWO 16d NAILS EACH.FASTEN PURLIN \ TO BL.00ICING WMVO I5d NAILS(MIN) Diag.Brace \ \ PROVIDEZrt BLOCKING BETWEEN THETRUSSES at 113 points SUPPORTINGTHEBRACEANDTHETWOTRUSSES it needed DN EfTHER SIDE AS NOTED.TOENAILBLOCI3NG ATTTACCH ou ONALe)RACE OBLOCTi G WIT—°' End Well (5)-Iad.COMMON WIRE NAILS, �•-e *•. CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCT URAL GABLETRUSSES MAY BE BRACED AS NOTED: STRUCTURAL METH001:AT AACHAMATCHWGGABLETRUSSTOTHEINSIDE GABLETRUSS FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAILING SCHEDULE. METHOD 2:ATTACH 2X SCABSTOTHHFACEOFEACHVERT1CAt SCASAL�lG MEMBER OI�THE STRUCTURAL GABLE PER THE FOLLOW ING SCAB ALL NAILING SCHEDULE.SCABS ARETO BE OF THE SAb1E SIZE GRADE AND SPECIES AS THE TRUSS VERTICALS NASUNG SCHEDULE: •FOR W IND SPEEDS 120 MPH(ASCE 7.96,02,05),150 MPH(ASCE 7--10)OR LESS,NAILALL 14MVIBERS WITH ONE ROW OF 10d(131-X 3')NAILS SPACED W O.C. -FOR W IND SPEEDS GREATER 12D MPH(ASCE 7.98,02,05},150 MPH(ASCE 7-10)NAIL ALL MEMBERS WITH TWO ROWS OF 10d 031•X 37 NAILS SPACED 6-O.C.(2X 4 STUDS MINIMUM) 0.14XIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALL BRACING METHODS SHOWN ON PAGE 1 ARE / VALID AND ARETOBE FASTENED TOTHE SCABS OR NLAYEDSTUD VERTICALSfUDS OFTHESTANDARD GABLETRUSS J ON THE INTERIOR SIDE OFTHE STRUCTURE. ` AN ADEQUATE DIAPHRAGM OR OTHER METHO, ffo CING MUST S:l'iUCTURAL 6EPRESENTTOPROVIDEFULLIATERAL tjR}'bRl b • GABLETA JSS / OTTOAI CHORD TO RESISTALL OUT OF PLANE •dA E ING"OWN IN THIS DETAIL IS FORTHE VERTIc*P _ Y..:-•f �/ :. NOTE:THIS DETAIL ISM MUSED ONLY FOR I 'z 869 = STRUCTURAL GABLES W MI INLAYED STUDS.TRUSSES W I TROUT INLAYED SiUDa^AAE hJ6i ADDRESSED HERE Q:• Rim _ STATE OF STANDARD ' / '•."ZORIDP`--'`� � GABLETRUSS S'OJYA.. 1 �>>�JIIlt111\\ 1109 COASTAL BAY BOYNTON 3C,FL 33435 i FEBRUARY 14,2012 STANDARD PIGGYBACK ST.PIGGY PLATE TRUSS CONNECTION DETAIL pp 0 MTek Ir kMbiM Cha-Wftld,MD Page 1 Of 1 o�o a McTek Industries.Inc. This detail is applicable for the following Wwtd conditions: ASCE 7-98,ASCE 7-02,ASCE 7-05,ASCE 7-10 Wind Standards under all endosure and exposure conditions as long as no uprrst exceeds 3777lbs. Refer to actual piggyback truss design drawing for uplifts. NOTE: This Detail is valid for one ply trusses spaced 24"o c.or less. PIGGYBACK TRUSS defer to actual truss design drawing for additional piggyback truss information. Attach piggyback truss to the base truss witit 3"xB"TEE-LOCK Mul i-Use connection plates spaced 48"o.c. Plates shall be pressed into the piggyback truss at 48'o.c.staggered from each face and named to the base truss with four(4)-6d(1.S"x0.099) nails in each plate to achieve a maximum uplift capacity of 3irr lbs. at each 3"x8"TEE-LOCK[Multi-Use connection plate- (Minimum of 2 pk6s) Attach each purtin to the top chord of the base truss. IJ (Purlins and connection by others) BASE TRUSS Refer to actual truss design drawing for additional base truss information. SPACE PURUNS ACCORDING TO THE fWXIMUM SPACNG ONTHE TOP CHORD DFTHE BASE TRUSS(SPACING NOT TO EXCEED W O.C.Q. A PURLN TO BE LOCATED AT EACH BASE TRUSS JOINT. •.cr ' VCENSF .•�� L _ N 34869 = 131 C � �= STATE OF =•.r?�� �� ;ONA%- 1109 COASTAL BAY BOYNTON BC,FL 33435 10/19/12 FEBRUARY 14.2012 TRUSSED VALLEY SET DETAIL ST VALLEY SYP mmsk Industries,Cheswffaid.Mo Page i of 1 GENERAL SPECIFICATIONS 1.NAIL SIZE=3.5'X 0.131'=16d Il_1` 2.INSTALL VALLEY TRUSSES(24-0.11 MAXIMUM)AND SECURE PER DETAILA Mi r'ek Industries.Inc. 3.BRACE VALLEY WEBS IN ACCORDANCE W ITN THE INDIVIDUAL DESIGN DRAWINGS. GABLE END.COAWON TRUSS 4.BASE TRUSS SHALL BE DESIGNED WITH A PURUN SPACING OR GRDERTRUSS EQUILIVANTTO THE RAKE DIMENSION OF THE VALLEYTRUSS SPACING. S.NAILING DONE PER NDS-Dt S.VALLEY STUD SPACING NOT TO EXCEED 4B'O.C. 7.ALL LUMBER SPECIES TO BE SYP. -- 1 i A q 1 1 1 1 SASETRUSSES VALLEYTRUSSTYPICAL I I -LL I VALLEY TRUSS TYPICAL GABLE END.COMMON TRUSS P 72 OR GIRDER TRUSS SEE DETAIL A BELOW(IYP.-) SECURE VALLEY FUSS W/ONE ROW OF15d NAILS 6"Q.C. WIND DESIGN PER ASCE 7.98.ASCE 7-02.ASCE 7-05 12D MPH WIND DESIGN PERASCE7-111 1SD MPH MAX MEAN ROOF HEIGHT a 30 FEET ATTACH 2X4 CONTINUOUS NO.2 SYP ROOF PITCH-MINIMUM 9;12 MAXIMUM 1DA2 TO THE ROOF WITWO 15d(0.131'X 3.5-)NAILS CATEGORY it BUILDING INTO EACH BASETRUSS. EXPOSURE C OR B WIND DURATION OF LOAD INCREASE:1IEoi I I I MAXTCP CHORD TOTAL LOAD-gApgv MAX SPACING-29 O.C.(BAS k%'� MINIMUM REDUCED DEAD F1' 7�F-•..: C�/ice ON THE TRUSSES N 34869 T ix � D1STATE OFDETAIL A / fiCORIDp`.•'`l��` (MAXIMUM V SHEATHING) : �\t Y�trrrlli►`� N.T.S. 1109 COASTAL BAY BOYNTON BC,FL 33435 OCTOBER 1,2006 LATERAL TOE-NAIL DETAIL ST TOENAIL SP R MTeklndustries,Chestetfield.MO page 1 oF1 ANDMUST HAVE)FULEL WOOD�pOR. (NAIL IL MUST BED I WITH VEN THROUGH D EXT AT THE BACK CORNER OFTHE MEMBER END AS SHOWN. '�Ij 2.THE END DISTANCE.EDGE DISTANCE,AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD_ MPTeI<Industries.Inc_ 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THETWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOE-NAIL SINGLE SHEAR VALUES PER NDS 2001 j1hinail) THIS DETAIL APPLICABLE TO THE THREE END DETAILS SHOWN BELOW DIAM. I SYP OF HF SPF IFS .131 882 80.6 ff74.2 BSA 591 p 135 93 5 ass 72.5 63.4 VIEVeSHOWNAREFOR .162 100.8 99.6 843 73.8 IU_USTRAMON PURPOSES ONLY Ni Z 128 74.2 67.9 B.9 1 570 'SU3 O .131 739 M.5 603 590 51.1 SIDE VIEW SICE VIEVV .148 R7 4 74.5 64.6 M.2 52.5 Np lw I267 3 NAILS eri L NFAR S10E NEAR SIDE VALUES SHOWW AI:E CApAcfiY PER TOE-NAIL NEAR SC APPLICABLE DURATION OF I_QaD INCREASES MAY BE APPLIED. NEAR SIDE NEAR SIC E7(AMPLE (3)-16d NAILS(.162'dram.X 3.SI WITH SPF SPECIES BOTTOM CHORD For load duration increase of 1.15: 3(nails)X 84.5(Ib/nail)X 1.15(DOL)=291.5 Ib Maximum Capacity ANGLE MAY ANGLE MAY ANGLE MAY VARY FROM VARY FROM VARY FROM 30"TO 60° 30'TO 60' 30°TO 600 45.00' 45.000 45.000 `,`1111tlltlt!!,! pus. •k '%f �' N 348ti9 ' 'U �� O'• 10/3.9/12 tL� •. STATE;OF :- �. 1109 MASTAL BAY BOYNTON BC,FL 33435 o� OCTOBER 1, 2006 UPLIFT TOE-NAIL DETAIL I ST-TOENAIL UPLIFT M-i rek Industries,Chaszrfield,MO Pagel Of 1 NOTES L�1 1.TOE tdAf LS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES WITH THE MEMBER o AND STAR T ED 113 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2.THE END DISTANCE,EDGE DISTANCE,AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD_ 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OFTHE BOTTOM CHORD SPECIES MTek Industries,Inc. OR TOP PLATE SPECIES FOR MEMBERS OF DIFFERENT SPECIES. END VIEW SIDE VIEW goo• TOP PLATE OF W NEAR SIDE 'LZL NEAR SIDE 113 VIEVS SHOWN ARE FOR FAR.SIDE ILLUSTRATION PURPOSES ONLY TOE-NAIL WITHDRAWAL VALUES PER NDS 2001(lb/nail) EXAM. SYP DF HF SPF SPF S 12 .131 58.5 49.1 31.6 299 20.3 p .135 ( 60.3 47.5 I 32.6 30.7 20.2 fa, .162 I 72.3 57.0 39.1 35.8 25.1 vo z 128 53.1 419 29.7 21.0 IS-4 of .131 543 429 293 27.7E213 189 N 148 6i,4 40.3 331 31.3 10/3.9/3.2 m T .120 45.9 3 �4 23A 153 O .128 49.0 38.6 26.5 25.0 17.0 ���� `US . 2 J CENS �� o .131 50.1 39.5 27.1 5.5 17?{ ` :- �1 F •,:� i `O 148 56.6 44.5 30.6 28.9 19 6 *'• ' N 34869 VALUES BLE DURATION ARE N OF LOAD PINCRE A NAIL. =-U � � APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE (3)-16d NAILS(.162"diam.x 3.5")WITH SPF SPECIES TOP PLATE _ STATE OF �iCJ`ForVMnd DOL of 1,33: 3(nails)X 36.8(Ibinall)X 1.33(DOL forwind)=146.81b Maximum Allowable UpGftReaction Due To Wmd For'Alnd DOL of 1.60: 3(nalls)X 36.8(Ib/na1)X 1.60(DOL forwind)=176.61b Maximum Allowable Uplift Reaction Due To Wind 1109 COASTAL BAY If the uplift reaction specified on the7russ Design BOYNTON BC,FL 33435 Drawing is more than 146.8 lbs(176.6lbs)another mechanical uplift connection must be used. USE(3)TOE,NAlIS ON 2.4 BEARING WALL ^'USE(4)TOE-NAILS ON 24 BEARING WALL