Loading...
HomeMy WebLinkAboutPHOTOVOLTAIC ROOF MOUNT SYSTEM114'-2"62'-8"114'-4"49'-6"4'-7"34'-8"6'-9"21'-3"NSEW5'-1"8'-10"23'-11"10'-6"NSEW5'-1"8'-10"23'-11"10'-6"SHEET INDEX:A-00: COVER SHEETA-01:SITE PLANS-01:ATTACHMENT DETAILE-01:ELECTRICAL LINE DIAGRAME-02:ELECTRICAL NOTESE-03:WARNING LABELSDS-01+DATA SHEET ROOF ACCESS POINTROOF ACCESS POINT(S) SHALL BE LOCATED IN AREASTHAT REQUIRE THE PLACEMENT OF GROUND LADDERSOVER OPENINGS SUCH AS WINDOWS OR DOORS AND ARELOCATED AT STRONG LOCATIONS OF BUILDINGCONSTRUCTION THAT DO NOT CONFLICT WITHOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.SCALE: NTS2SATELLITE VIEWA-00SCALE: NTS3VICINITY MAPA-00SCALE: 1/16" = 1'1PLOT PLANA-00PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC ROOF MOUNT SYSTEM34 MODULES-ROOF MOUNTED - 12.240 kW DC, 9.860 kW AC, 6251 ARLINGTON WAY, FORT PIERCE, FL 349516251 ARLINGTON WAYFRONT OF HOUSEROOF #3(14) Q CELLS Q.PEAK DUOBLK-G10+ / AC 360WSLOPE: 26°AZIM.: 80°ROOF ACCESS POINTGOVERNING CODESALL WORK SHALL CONFORM TO THE FOLLOWING CODESa. 2017 NATIONAL ELECTRICAL CODEb. 2020 FL BUILDING CODE - 7TH EDITIONc. 2020 FL BUILDING CODE - 7TH EDITION RESIDENTIALd. FLORIDA FIRE PREVENTION CODEe. ANY OTHER LOCAL AMENDMENTSREVCASEY LORANGE RESIDENCE 6251 ARLINGTON WAY, FORT PIERCE, FL 34951 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERA-00SHEET NAMEPROJECT NAMESIGNATURE WITH SEAL650 2ND LANEVERO BEACH, FL 32962, USAPHONE: 772-567-3104FAX: (772)567-4553Website: www.climatocsolar.comCOVERSHEETGENERAL NOTES:1.APPLICABLE CODE: 2020 FLORIDA BUILDINGCODE (7TH EDITION) & ASCE 7-16 MINIMUMDESIGN LOADS FOR BUILDING AND OTHERSTRUCTURES.2.LAG SCREW DIAMETER AND EMBEDMENTLENGTHS ARE DESIGNED PER 2020 FLORIDABUILDING CODE (7TH EDITION)REQUIREMENTS. ALL BOLT CAPACITIES AREBASED ON A SOUTHER YELLOW PINE (SYP)RESIDENTIAL WOOD ROOF RAFTERS ASEMBEDMENT MATERIAL.3.ALL WIND DESIGN CRITERIA AND PARAMETERSARE FOR HIP AND GABLE RESIDENTIAL ROOFS,CONSIDERING FROM A 7° TO A MAXIMUM 23°(5/12 TO A MAXIMUM 7/12 PITCH) ROOF INSCHEDULE. CONTRACTOR TO FIELD VERIFYTHAT MEAN ROOF HEIGHT DOES NOT EXCEED30'-0".4.ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511, AND IS THERESPONSIBILITY OF THE CONTRACTOR TOPILOT DRILL AND FILL ALL HOLES.5.ALL DISSIMILAR MATERIALS SHALL BESEPARATED WITH NEOPRENE WASHERS,PADS, ETC OR SIMILAR.6.ALL ALUMINIUM COMPONENTS SHALL BEANODIZED ALUMINIUM 6105-T5 UNLESSOTHERWISE NOTED.7.ALL LAG SCREW SHALL BE ASTM A276STAINLESS STEEL UNLESS OTHERWISENOTED.8.ALL SOLAR RAILING AND MODULES SHALL BEINSTALLED PER MANUFACTURERINSTRUCTIONS.9.CONTRACTOR SHALL ENSURE ALL ROOFPENETRATIONS TO BE INSTALLED AND SEALEDPER 2020 FLORIDA BUILDING CODE (7THEDITION) OR LOCAL GOVERNING CODE.FENCEROOF #1(13) Q CELLS Q.PEAK DUOBLK-G10+ / AC 360WSLOPE: 26°AZIM.: 260°DRIVEWAYSYSTEM SIZE: 12.240 kW DC9.860 kW ACMODULE TYPE & AMOUNT:(34) Q CELLS Q.PEAK DUO BLK-G10+ / AC 360WMODULE DIMENSIONS:(L/W/H) 67.6"/41.1"/1.57"INVERTER:(34) ENPHASE IQ7PLUS-72-2-US [240V]INTERCONNECTION METHOD: LOAD SIDE TAPROOF #2(07) Q CELLS Q.PEAK DUOBLK-G10+ / AC 360WSLOPE: 26°AZIM.: 170°PROPERTY LINEPROPERTY LINEMEXISTING INTERIOR LOAD CENTERMAIN HOUSEPROPERTY LINEPROPERTY LINEPOOLSEXISTING EXTERIOR METERMAIN PANEL TIED TOEXTERIOR UTILITY METERAHJ: SAINT LUCIE COUNTYTHIS DIGITAL PDF PLAN SET WAS ELECTRONICALLY SIGNED AND SEALEDBY JOHN ALGER, P.E. ON THE DATE SHOWN USING IDENTRUST. THISCOVER PAGE SEALS ALL SUBSEQUENT PAGES OF THIS PLAN SET.PRINTED COPIES ARE NOT CONSIDERED SIGNED AND SEALED AND ALLSHA-1 AUTHENTICATION CODE MUST BE VERIFIED. 8'-3"10'-5"9"6'-11"8'-10"11'-2"24'-6"12'-4"57'-11"43'-8"8'-10"28'-0"9'-8"NSEW8'-10"23'-11"10'-6"NSEW8'-10"23'-11"10'-6"SCALE: 1/8" = 1'-0"1SITE PLANA-01CIRCUIT #3 - 10 MODULESCIRCUIT #2 - 11 MODULESCIRCUIT #1 - 13 MODULESSYSTEM LEGENDREVCASEY LORANGE RESIDENCE 6251 ARLINGTON WAY, FORT PIERCE, FL 34951 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERA-01SHEET NAMEPROJECT NAMESIGNATURE WITH SEAL650 2ND LANEVERO BEACH, FL 32962, USAPHONE: 772-567-3104FAX: (772)567-4553Website: www.climatocsolar.comSITE PLAN6251 ARLINGTON WAYFRONT OF HOUSECONTRACTOR IS PERMITTED TO SHIFTAND/OR RELOCATE MODULES TO CLEARROOF TOP OBSTRUCTIONS AND FORIMPROVED PERFORMANCE. FIELDVERIFICATION OF ACTUAL DIMENSIONS ISREQUIRED,ROOF SECTIONSMODULE-14SLOPE-26°AZIMUTH-80°MATERIAL-W TILERAFTER SIZE-2"X4" @ 24" O.C.MODULE- 07SLOPE-26°AZIMUTH-170°MATERIAL-W TILERAFTER SIZE-2"X4" @ 24" O.C.MODULE- 13SLOPE- 26°AZIMUTH- 260°MATERIAL- W TILERAFTER SIZE-2"X4" @ 24" O.C.ROOF#01ROOF#02ROOF#03CIRCUIT(S)GENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO SEE RAFTERS SHALL BEINSTALLED AS SHOWN IN SHEET S-01 AND ASFOLLOWS FOR EACH WIND ZONE:WIND ZONE 1: 6'-0" O.C.WIND ZONE 2e, 2r, AND 3 : 4'-0" O.C.2) PERIMETER WIDTH IS 4 FT IN ALL CASES AS PER THE2020 FBC 7TH EDMODULE RATING IS -75PSF SO IT MAY BEINSTALLED IN ANY ROOF ZONES.ROOF #01ROOF #024 FT SQUARE CORNERSARE ZONE 3ZONE 2e IS A 4 FT WIDEZONE ALONG THE EAVEZONE 2r IS A 4 FT.ZONE FROM RIDGE DOWNZONE 1PRESSURES WERE INTERPOLATED FROM THE COMPONENTS ANDCLADDING TABLE FOR HIP ROOFS P26 OF THE 2020 FBC 7TH EDRESIDENTIAL FOR RISK II EXPOSURE B ENCLOSED STRUCTURES WITHMEAN ROOF HEIGHT OF 30 FT. AN ADJUSTMENT FACTOR OF .94 WASUSED TO CONVERT TO EXPOSURE B AT MEAN ROOF HEIGHT OF 21 FT.WIND SPEED USED IS 157MPH, ROOF PITCH IS 26 DEGREES ANDAFFECTED AREA IS 18 SQ FTNEW DEDICATED PV SYSTEM COMBINER PANEL.34 NEW Q CELLS Q.PEAK DUO BLK-G10+ / AC 360WMODULES WITH NEW 34 - ENPHASE IQ7PLUS-72-2-US[240V] MICROIN VERTERS, MOUNTED ON THE BACK OFEACH MODULES.= CONDUIT EXTERIOR RUN= ATTACHMENT POINTS= TRUSS= ROOF OBSTRUCTIONS= WIND ZONE 1= RACKING SYSTEM= WIND ZONE 2e AND 2r= WIND ZONE 3NEW SOLADECK JUNCTION BOX.JBCMMEXISTING EXTERIOR METER MAIN COMBO PANEL &POINT OF INTERCONNECTIONEXISTING INTERIOR LOAD CENTERSNEW PHOTOVOLTAIC UTILITY DISCONNECTSWITCH. LOCATED WITHIN 10' OF MSP.ACMODULE, ARRAY WEIGHT(LOAD CALC'S)Number of Modules34Module Weight46.3LBSTotal Module (Array) Weight1574.20LBSNumber of Attachment point60Mounting System Weight(Per Module)1.5LBSMounting System Weight90.00LBSTotal System Weight(Module Weight + Mounting System Weight)1664.20LBSWeight at Each Attachment Point(Array Weight / Number of Attachment Point)26.24LBSModule Area (67.6"x41.1")19.29SqFtTotal Array Area656.00SqFtDistributed Load(Total System Weight / Total Array Area)2.48Per SqFtTotal Roof Area2214SqFtTotal Percentage or Roof CoveredTotal Array Area / Total Roof Area)*10029.63%DESIGN CRITERIAROOF LIVE LOAD (psf)20GROUND SNOW LOAD (psf)0WIND SPEED (mph)157EXPOSURE CATEGORYBROOF HEIGHT (ft.)21ROOF LENGTH (ft.)58ROOF WIDTH (ft.)44PARAPET HEIGHT (ft.)0DESIGN CALCULATIONWIDTH OF PRESSURE COEFFICIENTROOF LENGTH x 10% (ft.)4.1ROOF HEIGHT x 40% (ft.)8.4ZONE WIDTH "A"4.0'WIND ZONE 1-30.400WIND ZONE 2e, 2r AND 3-42.300ACCMMSJBTHIS PAGE IS PART OF A DIGITALLYSEALED PDF PLAN SET THAT WASELECTRONICALLY SIGNED AND SEALEDBY JOHN ALGER, P.E. ON THE COVERPAGE. PRINTED COPIES ARE NOTCONSIDERED SIGNED AND SEALED.ROOF #03 REVCASEY LORANGE RESIDENCE 6251 ARLINGTON WAY, FORT PIERCE, FL 34951 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERS-01SHEET NAMEPROJECT NAMESIGNATURE WITH SEAL650 2ND LANEVERO BEACH, FL 32962, USAPHONE: 772-567-3104FAX: (772)567-4553Website: www.climatocsolar.comMOUNTDETAIL"AS PER THE FBC 107.3.5, I HAVE EVALUATED THE STRUCTURE ANDCERTIFY THAT THE ADDITION OF A SOLAR PV SYSTEM WILL NOTMEASURABLY AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDINGBASED ON THE FOLLOWING:1. UPLIFT FORCES NOTED ARE THE SAME AS ACTING ON AN EXPOSEDPORTION OF THE ROOF. NO ADDITIONAL LOADS ARE ADDED BY ADDINGA SOLAR SYSTEM. ATTACHMENTS ARE INSTALLED INTO THE TRUSSSYSTEM THUS DIRECTING FORCES INTO THE STRUCTURALCOMPONENTS OF THE BUILDING. IN FACT, UPLIFT AFFECTS WILLACTUALLY BE REDUCED SOMEWHAT BY THE PRESENCE OF AN AIR GAPBETWEEN THE ROOF SURFACE AND THE TOP SURFACES OF THE PVMODULES WHICH TENDS TO LOWER THE AVERAGE UPLIFT PRESSURES.2. THE ONLY ADDED LOAD WILL BE THE WEIGHT OF THE PV MODULESAND ATTACHMENT SYSTEM OF RAILS AND FLASHINGS WHICH TYPICALLYIS UNDER 4 PSF. THIS IS AN INSIGNIFICANT ADDITIONAL LOAD TO THESTRUCTURE.SCALE: NTS1ATTACHMENT DETAIL (SIDE VIEW)S-01SCALE: NTS2ATTACHMENT DETAIL (ENLARGED VIEW)S-01THIS PAGE IS PART OF A DIGITALLYSEALED PDF PLAN SET THAT WASELECTRONICALLY SIGNED AND SEALEDBY JOHN ALGER, P.E. ON THE COVERPAGE. PRINTED COPIES ARE NOTCONSIDERED SIGNED AND SEALED.SOLAR MODULE(E) W TILE ROOF(E) 2"X4" RAFTER @ 24" O.C.L-FOOT(2) 5/16"DIA. X 3"MIN.EMBEDMENT LAG SCREWAT EACH ATTACHMENT POINTINTO EXISTING FRAMING(E) 2"X4" RAFTER @ 24" O.C.GROUNDING & END/MID CLAMPPV MODULEW TILE REPLACEMENTIRONRIDGE XR100 RAIL REVCASEY LORANGE RESIDENCE 6251 ARLINGTON WAY, FORT PIERCE, FL 34951 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERE-01SHEET NAMEPROJECT NAMESIGNATURE WITH SEAL650 2ND LANEVERO BEACH, FL 32962, USAPHONE: 772-567-3104FAX: (772)567-4553Website: www.climatocsolar.com3-LINEDIAGRAMRooftop conductor ampacities designed in compliancewith art. 690.8, Tables 310.15(B)(2)(a), 310.15(B)(3)(a),310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9.Location specific temperature obtained from ASHRAE2017 data tablesAMBIENT TEMP (HIGH TEMP 2%)RECORD LOW TEMP0°C33°CCONDUIT HEIGHT0.5"ROOF TOP TEMP55°CCONDUCTOR TEMPERATURE RATE OFF ROOF75°CCONDUCTOR TEMPERATURE RATE ON ROOF90°CENPHASE Q CABLE TO BE ATTACHED TO RAILMIN. 3-1/2" ABOVE ROOF SURFACESYSTEM DATATOTAL MODULES:34TOTAL INVERTERS:34SYSTEM RATINGS:12.240kW DC STCWIREQTYWIRETAG #CONDUITWIRE TYPEINVERTERQTY:NOC:CONDUITFILL:TEMPRATING:WIREAMPTEMPDE-RATE:WIREOCP:GRNDSIZEGRND WIRETYPEWIREGAUGE:TERMINAL75°C RATING:NEC:STRINGAMPSxx=xx=1.251.21A13#6SBC19.66A28.80A35A90°35Axx=1.251.21A13#8THWN-219.66Axx=24.32A90°65Axx=1.251.21A34#8THWN-251.43Axx=61.10A75°30A#1240A#1065A#63/4" EMTWIRE FROM - -JUNCTION BOX TO COMBINER PANELCOMBINER PANEL TO METER MAIN PANELARRAY TO JUNCTION BOX123THWN-2THWN-26N/A0.8031.000.960.760.94TRUNKCABLETHWN-26120% RULEBUS BAR RATING X 120%) - MAIN BREAKER RATING=MAX. PV OCPD(200A x 120%) - 200A = 40AGL1L1L2L213 MICRO-INVERTERS IN BRANCH CIRCUIT #1L2L2L1L111 MICRO-INVERTERS IN BRANCH CIRCUIT #2L2L2L1L110 MICRO-INVERTERS IN BRANCH CIRCUIT #3TERMINATOR CAP ON LAST CABLECONNECTOR AC TRUNK CABLE (TYP)L1L2NGN20AG20A20A123/4" EMTELECTRICAL CONDUIT TO ALLOW ROMEX IN UNEXPOSEDLOCATIONS SUCH AS ATTICS, EMT, FLEX PIPE, SMURF PIPEPVC OR ANY CONDUIT THAT MEETS NEC 2017 REQUIREMENTSFOR AC CURRENT.GN60A FUSES(N) BLADE TYPEFUSIBLE AC DISCONNECTNEMA 3R 60A-2P 120/240VAC(VISIBLE, LOCKABLE, LABELED)(N) COMBINER PANEL ENPHASE IQCOMBINER X-IQ- AM1-240-3 64A/240VCONTINUOUS, PROTECTION MAX80A BREAKER ON SOLAR OUTPUT;WITH 10 KAIC CIRCUIT BREAKERS(N) SOLADECK BOX OR UL 1741APPROVED EQUIVALENTTO TRANSITION FROMQ-CABLE TO THWN-2 WIRENO FUSE REQUIRED(34) (ENPHASE IQ7PLUS-72-2-US [240V]) MICROINVERTERS240VAC, 1.21A MAXCEC WEIGHTED EFFICIENCY 97.0%NEMA 4R, UL LISTED, INTERNAL GFDIM*IQ Envoy15A3LOAD SIDETAP(E) LOADS(E) LOADSEXISTINGWIRESNGNEXISTING GROUNDINGELECTRODE SYSTEMMPOINT OF INTERCONNECT, LOAD SIDE TAPEXISTING 240V/200A BUS BARRATING, METER MAIN COMBOPANEL, SINGLE PHASE, WITH A200A MAIN DISCONNECTEXISTING INTERIOR240V/200A INTERIOR LOADCENTER WITH NEW 200AMAIN BREAKER(E) 200ATHIS PAGE IS PART OF A DIGITALLYSEALED PDF PLAN SET THAT WASELECTRONICALLY SIGNED AND SEALEDBY JOHN ALGER, P.E. ON THE COVERPAGE. PRINTED COPIES ARE NOTCONSIDERED SIGNED AND SEALED.(E) LOADSINTERIOR OF BUILDING(E) LOADS3(E) 200A 1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, ANDLABELED FOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND90 DEGREE C WET ENVIRONMENT.3.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPSSHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSEAS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.4.WORKING CLEARANCES AROUND ALL NEW AND EXISTINGELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.5.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OFSYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARYOUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TOFULFILL APPLICABLE CODES AND STANDARDS.6.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, ANDCONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALLSIZE THEM ACCORDINGLY.7.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELYLABELED AND READILY VISIBLE.8.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEENMODULE FRAME AND MODULE SUPPORT RAIL, PER THEGROUNDING CLIP MANUFACTURER'S INSTRUCTION.9.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUSCOPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-INLUG.10.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THESERVICE ENTRANCE.11.WORKING CLEARANCES AROUND THE EXISTING AND NEWELECTRICAL EQUIPMENT WILL BE MAINTAINED INACCORDANCE WITH NEC ARTICLE 110.26.12.ALL EQUIPMENT INSTALLED SHALL BE LISTED BY ANATIONALLY RECOGNIZED TESTING LABORATORY (NRTL)PER NEC ARTICLE 110.3.13.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.14.ALL LABELS OR MARKINGS SHALL BE VISIBLE AFTERINSTALLATION. THE LABELS SHALL BE REFLECTIVE, AND ALLLETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUMHEIGHT OF 9.5 MM (3/8 IN) IN WHITE ON A RED BACKGROUND.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED ASSUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) ANDARTICLE 310.8 (D).16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BESUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE310.8 (C).REVCASEY LORANGE RESIDENCE 6251 ARLINGTON WAY, FORT PIERCE, FL 34951 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERE-02SHEET NAMEPROJECT NAMESIGNATURE WITH SEAL650 2ND LANEVERO BEACH, FL 32962, USAPHONE: 772-567-3104FAX: (772)567-4553Website: www.climatocsolar.comSYSTEM NOTES:1.ENPHASE IQ7 / 7PLUS MICROINVERTERS DO NOT REQUIREGROUNDING ELECTRODE CONDUCTORS OR EQUIPMENTGROUNDING CONDUCTORS. THE MICROINVERTERS ITSELF HASCLASS II DOUBLE-INSULATED RATING, WHICH INCLUDES GROUNDFAULT PROTECTION.2.ENPHASE Q CABLE HAS NO NEUTRAL WIRE - (2 WIRE DOUBLEINSULATED CABLING)3.MODULES ARE BONDED TO RAIL USING UNIRAC INTEGRATEDGROUNDING.4.RAILS ARE BONDED WITH UL 2703 RATED LAY-IN LUGS5.SYSTEM IS UNGROUNDED6.BARE COPPER IS TRANSITIONED TO THHN/THWN-2 VIAIRREVERSIBLE CRIMP; GEC TO BE CONTINUOUS PER CEC250.64(C)7.SUB-BRANCHES ARE CENTER-FED AT JBOX TO MAKE ONE TOTALBRANCH CIRCUIT.8.ENPHASE IQ ENVOY INSIDE IQ COMBINER REQUIRES A NEUTRALTO BE LANDED AT THE NEUTRAL BUSS AT MAIN PANEL PERENPHASE INSTALLATION INSTRUCTIONS.9.ENPHASE MICROINVERTERS ARE ALL RAPID SHUTDOWN READYPER NEC 690.12ELECTRICAL NOTES:ELECTRICALNOTESCERTIFICATE OFAUTHORIZATION#31930ENGINEER OF RECORDJOHN L. ALGERPROFESSIONAL ENGINEERFL. LICENSE NO. 74730PHOTOVOLTIAC AC OUTPUTAC OUTPUT CURRENTNOMINAL AC VOLTAGE240V41.14ALABLESRATED MPP CURRENTRATED MPP VOLTAGE34.31 V10.49 APHOTOVOLTAIC DC PER INVERTERMAX SYSTEM VOLTAGESHORT CIRCUIT CURRENT41.18 V11.04 VSYSTEM DATA# STRINGS:03SMALLEST STRING:10LARGEST STRING:13TOTAL MODULES:34TOTAL INVERTERS:34SYSTEM RATINGS:12.240kW DC STCBATTERY RATING:N/AINVERTER SPECIFICATIONSMANUFACTURERMAX. POWER AT 40 C60 VOLTSNOMINAL AC VOLTAGE235 WATTSMAX. AC CURRENT290 VOLTSMAX. OCPD RATINGMAX. PANELS/CIRCUITSHORT CIRCUIT CURRENT1.21 AMPS20 AMPSMAX. DC VOLT RATING1315 AMPSENPHASE ENERGY IQ7PLUS-72-2-US I JOHN L ALGER, PE# 74730, ANENGINEER PURSUANT TOCHAPTER 471 OF THE FLORIDASTATUTES, HERE BY STATE THATI HAVE EVALUATED ALL OF THECOMPONENTS AND THE SYSTEMAS A WHOLE AND CERTIFY THATIT MEETS OR EXCEEDS THEREQUIREMENTS OF:2020 FBC 7TH ED, 2020 FBC 7THED RESIDENTIAL & 2017 NECTHIS PAGE IS PART OF A DIGITAL SEALEDPDF PLAN SET THAT WAS ELECTRONICALLYSIGNED BY JOHN ALGER, P.E. ON THECOVER PAGE. PRINTED COPIES ARE NOTCONSIDERED SIGNED AND SEALEDPV MODULE RATING @ STCMANUFACTURERMAX. POWER-POINT CURRENT (IMP)MAX. POWER-POINT VOLTAGE (VMP)OPEN-CIRCUIT VOLTAGE (VOC)SHORT-CIRCUIT CURRENT (ISC)10.49 AMPS34.31 VOLTS41.18 VOLTS11.04 AMPSNOM. MAX. POWER AT STC (PMAX)MAX. SYSTEM VOLTAGEVOC TEMPERATURE COEFFICIENT360 WATT1000 VDC-0.27° %/°C Q CELLS Q.PEAK DUO BLK-G10+ / AC 360W INVERTER OUTPUT CONNECTIONPHOTOVOLTAIC SYSTEMCOMBINER PANELNOTES AND SPECIFICATIONS:·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIREDBY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ.·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USINGEFFECTIVE WORDS, COLORS AND SYMBOLS.·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT ORWIRING METHOD AND SHALL NOT BE HAND WRITTEN.·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THEENVIRONMENT INVOLVED.·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCTSAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.·DO NOT COVER EXISTING MANUFACTURER LABELS.WARNING!SOURCES: UTILITY GRIDAND PV SOLAR ELECTRICSYSTEMDUAL POWER SUPPLYLABEL LOCATION:UTILITY SERVICE METER AND MAIN SERVICEPANEL.PER CODE(S): NEC 2017: 705.12(D)(3), NEC 2011: 705.12(D)(4)ELECTRICAL SHOCK HAZARDDO NOT TOUCH TERMINALS.TERMINALS ON LINE AND LOADSIDES MAY BE ENERGIZED INTHE OPEN POSITIONWARNING!LABEL LOCATION:INVERTER(S), AC DISCONNECT(S), ACCOMBINER PANEL (IF APPLICABLE).PER CODE(S): CEC 2019: 690.17(B),NEC 2017: 690.17(E), NEC 2011: 690.17(4)WARNING!DO NOT RELOCATE THISOVERCURRENT DEVICELABEL LOCATION:ADJACENT TO PV BREAKER (IF APPLICABLE).PER CODE(S): CEC 2019: 705.12(B),NEC 2017: 705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7)!DO NOT ADD LOADSWARNINGLABEL LOCATION:PHOTOVOLTAIC AC COMBINER (IF APPLICABLE).PER CODE(S): CEC 2016: 705.12(D)(2)(3)(c), NEC2017: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4)WARNING: PHOTOVOLTAICPOWER SOURCEWARNING: PHOTOVOLTAICPOWER SOURCELABEL LOCATION:INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACHTURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULLBOX CONTAINING DC CIRCUITS.PER CODE(S): CEC 2019: 690.13, NEC 2017: 690.31(G)(3),690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012:605.11.1.4LABEL LOCATION:AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OFINTERCONNECTION.PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.54, NEC 2011: 690.54MAXIMUM AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE: 41.14 AMPS 240 VACPHOTOVOLTAIC AC DISCONNECTREVCASEY LORANGE RESIDENCE 6251 ARLINGTON WAY, FORT PIERCE, FL 34951 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERE-03SHEET NAMEPROJECT NAMESIGNATURE WITH SEAL650 2ND LANEVERO BEACH, FL 32962, USAPHONE: 772-567-3104FAX: (772)567-4553Website: www.climatocsolar.comWARNINGLABELSEMERGENCY RESPONDERTHIS SOLAR PV SYSTEM ISEQUIPPED WITH RAPID SHUTDOWNTURN RAPIDSHUTDOWN SWITCH TOTHE "OFF" POSITIONTO SHUTDOWN ENTIREPV SYSTEMSOLARELECTRICPV PANELSNEC690.56(C)(1) AND NEPA 111.12.2.1.1.1.1,11.12.2.1.4THIS PAGE IS PART OF A DIGITALLYSEALED PDF PLAN SET THAT WASELECTRONICALLY SIGNED AND SEALEDBY JOHN ALGER, P.E. ON THE COVERPAGE. PRINTED COPIES ARE NOTCONSIDERED SIGNED AND SEALED.