HomeMy WebLinkAbout7901 Sebastian RD - SS Designs ,11111111111 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D. o`oo�'Ew•�.•y�,,��� 8.9 7 IOW SOLAR ARRAY PLANS HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS P?•��G ENS"; DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE No 8747s PROJECT DESCRIPTION: E *: FOR 26 MODULES - MISSION SOLAR: MSE345SX5T SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. - 26 INVERTERS - ENPHASE: IQ7-60-2-US 90 STATE OF :��40 MAX 0 N �E B BAN C Digitally signed by Andrew Hall GOVERNING CODES: Andrew L}_ Hall, PE FLg747g Date: 2022.01.05 10:47:53 ,��'!,`,rs 10 0 A �� ,,, 7901 S E BAST A N R D 2020 FLORIDA PLUMBING CODE, 7TH EDITION -05'00' ��Ilnnnn11/�� 2020 FLORIDA BUILDING CODE, 7TH EDITION 2020 FLORIDA MECHANICAL CODE, 7TH EDITION FORT PUCE, FL0 R DA 34951 NEC 2017 WINDSPEED DESIGN DATA PER FBCR 2020 = NFPA 1 2018 WIND SPEED 170 MPHce cn RISK CATEGORY II o EXPOSURE C w DRIVEWAY GUST FACTOR t0.18 "A" DIMENSION 3 Ft C) ROOF PRESSURE FOR COMPONENTS AND CLADDING o 0 cn N O N GABLE ROOF o; Q N 0 ZONE 1 +23.3 PSF -57.6 PSF o o ZONE 2E +23.3 PSF -57.6 PSF TYP. EAVE ZONE 2N +23.3 PSF -84.1 PST DISCONNECT ZONE 2R +23.3 PSF -84.1 PST U) MIN. 4' CLEARANCE ZONE 3E +23.3 PSF -84.1 PSF z o a "' PER NEC 110.26(A) HIP ROOF c o ZONE 1 +23.3 PSF -52.3 PST :D Q M (D ZONE 2R +23.3 PSF -68.2 PST U-) _ o Q — ZONE 2E +23.3 PSF -73.5 PSF Z w o ZONE 3 +23.3 PSF -73.5 PSF w (DL' L11 v = r7 H Lo Ut N z N TYP. RIDGE z ii _ _ w Lu CIO g � I I I I z � ,--�---- � 1 /may cl- I♦ �'1f f � � t 1 1 H 1 • I 1 I z 1 1 I D I d I 1 1 (D 1 (D I Z 1 1 1 I 1 1 1 I s PLAN 1 I ?r I n l PLAN OBSTRUCTION 6ahle and Flat knots T°{0 S 45° Hip fteah 7"-c 9 S 451 GENERAL NOTES: MISSION SOLAR: 1. THIS IS TO CERTIFY THAT TO THE BEST OF DRAWING INDEX: MSE345SX5T (TYP) MY KNOWLEDGE AND BELIEF, THESE PLANS o 3 CONFORM WITH FLORIDA BUILDING CODE 2020 Li m 3' MIN. TYP WITH ALL SUPPLEMENTS AND ADDITIONS. S-1 COVER o 2. ALL PRooucTs To BE INSTALLED PER S-2 ARRAY LAYOUT & DETAILS " `° uj MANUFACTURER'S WRITTEN SPECIFICATIONS. � L S-3 ELECTRICAL o w o I, ANDREW D. HALL PEA 87479 AN ENGINEER S-4 NOTES N Z �' LICENSED PURSUANT TO CHAPTER 471, CERTIFY S-5 SPECIFICATIONS THAT THE PV ELECTRICAL SYSTEM AND w w w TYP. EAVE MODULE ROOF LAYOUT ELECTRICAL COMPONENTS ARE DESIGNED AND S-6 SPECIFICATIONS U Q U APPROVED USING THE STANDARDS CONTAINED IN S-7 SPECIFICATIONS NTS THE MOST RECENT VERSION OF THE FBC, FBC S-8 SPECIFICATIONS DWG. N0. 107. S-9 SPECIFICATIONS S- 1 o�•�`PEW '�! ''��, y THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D. HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS rc E N s DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE No $747s SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. = * = 0: STATE OF :.�/ �`'•• J 2 Q 3/8"-16 X 3/4" HEX HEAD BOLT EVEREST IMC CLIP m 3/8" - 16 FLANGE NUT (2) 5/16" DIA SS LAG SCREW w 2-1/2" EMBED MIN. PV MODULE U M O U �w I m N Z N CD Z CDK2 SPLICE FOOT XL;j W r Q 0 cn EVEREST o EVEREST CROSSRAIL 48-X (nPTyp AIL 48 X ) � J EXISTING ROOF TRUSS EXISTING UNDERLAYMENT K2 SPLICE FOOT X TOP VIEW U z o 1 2" PLYWOOD (TYP) NTS o o (2) 5/16" DIA SS LAG SCREW J ¢ o 2-1/2" EMBED MIN. o Q TYPICAL SHINGLE ROOF ATTACHMENT NTS z w H :� W O W U = M H Ln Ln N Z N z d r W co W Z O a_ z K2 SPLICE FOOT X 24" MAX. O.C. EVEREST IMC CLIP (TYP) (TYP) EVEREST EC CLIP (TYP) wC'� EVEREST EC CLIP MISSION SOLAR: MISSION SOLAR: z (TYP) MSE345SX5T EVEREST IMC CLIP MSE345SX5T Q (TYP) (TYP) (TYP) z � w V W J U m Q W U Z N UX m o� Q Ll cm cn EVEREST IMC CLIP EVEREST CROSSRAIL 48-X (TYP) EVEREST EC CLIP o w o 0 K2 SPLICE FOOT X (TYP) (nP) Z U N (TYP) TYPICAL SHINGLE ROOF LAYOUT W w o Of NTS U a DWG. NO. S-2 III/11111I THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D. ���•oPEw_�, y�.,�� HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS ��•`'P�•��cENSFq�� DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE No 8747s SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. = * = c= STATE OF J 2 Q m m im #6 THWN-2 (3 CONDUCTOR) NOTE: _ 3/4" EMT, FMC, FOR EXTERIOR ALL INVERTERS ARE EQUIPPED U APPLICATION USE PVC OR W/ INTERNAL RAPID SHUTDOWN LFMC/LFNMC CONDUIT 6 THWN-2 (3 CONDUCTOR) SYSTEM PER NEC 690.12 o 1 N L2 L1 3/4" EMT, FMC, FOR EXTERIOR m z N LOCKABLE FUSED APPLCATION USE PVC OR PV AC DISCONNECT LFMC/LFNMC CONDUIT ENPHASE Q CABLE MISSION SOLAR: MSE345SX5T 3 w J Z METER 60A 240V 2-POLE #10 THWN-2 (3 CONDUCTOR) ENPHASE Q CABLE Q-12-10-240 W/ ENPHASE IQ7-60-2-US N o 40A RK-1 FUSE 3/4" EMT, FMC, FOR EXTERIOR Q-12-10-240 (TYP) INVERTER 0 APPLCATION USE PVC (TYP) J OR LFMC CONDUIT -' z o o rry o N L2 L1 AC m J ¢ o M L1 L1 DC p J o L2 L2 NO. 1 N0. 13 N N SPACE 20 EVEREST CROSSRAIL z o SPACE 20 48-X (TYP) � W O 20 W U = M Z G NO. 1 NO. 13 NOTE: z � M ALL STRINGS TO HAVE Lu co-- 6 THWN-2 G AC AC TERMINATORS & SEALING CAPS L o DC DC INSTALLED PER MANUFACTURER'S Cl cl- 40 760OV/ K COMBINER BOX SPECIFICATIONS z NEUTRAL GROUNDON-FUSEDON RESIDENTIAL N BOX ENPHASE Q CABLE MISSION SOLAR: MSE345SX5T 6 BARE COPPER GEC BOND AT Q-12-10-240 W/ ENPHASE IQ7-60-2-US ENPHASE IQ COMBINER PLUS RACKING SYSTEM (TYP) INVERTER W/ (2) 20 AMP BREAKER (SEE NOTE #2) NEUTRAL GROUND AC PANEL 200 AMP/240V N Z O U m Q U O Q m � � N L� ON Z J U U N z cn � U O W J U d ¢ W W. NO. S-3 \\►►111111/j THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D. ,���.�Q�E E.�..y�` HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS P.<\c Ns z..x DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE = NO 8747s SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. = * = �: STATE OF :kt�/ NOTES: i��i;�`S'�.� O R 1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT is�ONA�- MODULE SPECIFICATION INVERTER SPECIFICATION SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND ��Nnnnl►\ MODULE MAKE MISSION SOLAR INVERTER MAKE ENPHASE STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION. MODULE MODEL MSE345SX5T INVERTER MODEL IQ7-60-2-US 2. ALL COMPONENTS Musr BE GROUNDED PER NEC 690.43. 3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D). _ FSEC CERTIFICATION # MAX AC POWER OUTPUT 250 VA 4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS o PMAX (STC) 345 W MAX. INPUT VOLTAGE 48 V RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPLIANCE WITH THE VOC (STC) 41.00 V NOM. DC VOLTAGE @ 240V 240 V ITEMS IDENTIFIED IN NOTE 1. m 5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING w VMPP (STC) 33.37 V NOM. AC VOLTAGE 16-48 V Y MAX. CONTINUOUS OUTPUT CURRENT 1.00 A MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ "WARNING-ELECTRIC SHOCK HAZARD - DO W ISO (STC) 10.92 A NOT TOUCH TERMINALS - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN IMPP (STC) 10.34 A MAX. DC CURRENT 15.0 A POSITION OR EQUIVALENT. NOCT 44 C MAX. DC POWER (STC) 350 W 6. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON TC ISO 0.039 %/C CEC EFFICIENCY 97 % THE PREMISES AT SERVICE ENTRANCE. o Mo TC VOC C.) N 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12. -0.262 %/C m N O N TO PMPP 8. PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION. Z `� -0.361 % C 9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED m OPERATING TEMP. -40-+85 C z o TO DIRECT SUNLIGHT. WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE w z HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO o o 3.OM (10ft) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICH EVER IS LESS. SAFETY LABELS AND MARKINGS GENERAL NOTES: NEC 310.15 (B)(2) I�I /� I�I �� �D�`�fY I�V �`0 fY I T/� �`T 10. ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE J N AN I\CJ I� I CONTACT I A I NEC. r, 1. EQUIPMENT SUCH AS INVERTERS AND SOLAR MODULES HAVE 12. PV ARRAY INTERCONNECTION TO BE MADE WITH BACK-FEED BREAKER. `n CD PRE-APPLIED LABELS FOUND HEREIN SHALL BE APPLIED TO SUCH US SOLAR 3. cFl BUILT IN To ALL INVERTERS. o EQUIPMENT FOR INFORMATIONAL PURPOSES. H 2. LABELS AND MARKINGS SHALL BE APPLIED TO COMPONENTS IN 1 —8 0 0—J 51 —J 4 J U r ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC. Q o 3. ALL REQUIRED PRODUCT SAFETY AND WARNING SIGNAGE SHALL BE UV `9 cif C-)Z wL � RESISTANT OUTDOOR-RATED LAMINATED VINYL IN ACCORDANCE WITH00 ANSI Z535.4-2011. w O 4. ALL LABELS SHALL BE REFLECTIVE PER NFPA 11.12 H Ln SAFETY AB B B Lu SAFETY LABELS AND MARKINGS LEGEND N w z CD A. LOCATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN cl- SERVICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT z POCC. SOLAR PHOTOVOLTAIC SYSTEM A� MAIN SERVICE DISCONNECT MARKING ® -WARNING- -WARNING- ELECTRIC SHOCK HAZARD. THE DC A LABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE AUTHORIZED PERSONNEL ONLY CONDUCTORS OF THIS PHOTOVOLTAIC DISCONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED CURRENT (DC) PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL BE RED WITH RATED AC CURRENT: 32.5A AUTHORIZED PERSONNEL ONLY WHITE CAPITAL LETTERS AT LEAST 3/4 IN. IN HEIGHT AND IN A NOMINAL AC VOLTAGE: 240V LOCATION: DISCONNECTS, INVERTERS, NONSERIF FONT, TO READ: "WARNING: PHOTOVOLTAIC POWER SOURCE." LOCATION: MAIN PV PANEL JUNCTION BOXES, OTHER ENCLOSES HOLDING DC CONDUCTORS THE MATERIALS USED FOR THE LABEL SHALL BE REFLECTIVE, WEATHER RESISTANT, AND SUITABLE FOR THE ENVIRONMENT. CIRCUIT DISCONNECTING MEANS MARKING PHOTOVOLTAIC DISCONNECT EMERGENCY RESPONDER: o THIS SOLAR PV SYSTEM IS „ m z A PERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT EQUIPPED WITH RAPID SHUTDOWN Z N BREAKER CONTROLLING THE INVERTER OR OTHER PHOTOVOLTAIC SYSTEM Ai RAPID ELECTRICAL CONTROLLER SERVING AC AND DC PHOTOVOLTAIC SYSTEMS. -WARNING- SHUTDOWN SWITCH TO 50 P� '° N THE LABEL SHALL HAVE CONTRASTING COLOR WITH CAPITAL LETTERS AT ELECTRIC SHOCK HAZARD THE "OFF" POSITION o DO NOT TOUCH TERMINALS. TERMINALS ON TO SHUT DOWN (n Z LEAST 3/8 IN. HEIGHT AND IN A NONSERIF FONT, TO READ: BOTH THE LINE AND LOAD SIDES MAY BE ENTIRE PV SYSTEM _ N c cn cn "PHOTOVOLTAIC DISCONNECT." THE LABEL SHALL BE CONSTRUCTED OF ENERGIZED IN THE OPEN POSITION. w o o :mJ o O DURABLE ADHESIVE MATERIAL OR OTHER APPROVED MATERIAL. LOCATION: AC DISCONNECT(S) z DWG. NO. S-4 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D. �•�` ''��, HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THISG E N• F�. '', DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE No 8747s SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. = * = STATE OF P P �� • Enphase IQ 7 and IQ 7+ Microinverters with Integrated MC4 Connectors PRELIMINARY INPUT DATA(DC) IQ7-60-M-US IQ7PLUS-72-M-US Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ J SPECIFICATIONELECTRICAL � ' Module compatibility 60-cell PV modules only 60-cell/120-half-cell and 72- x Product Type MSExxxSXST(xxx=P-) Solar Cells P-type mono-crystalline silicon cell/144-half-cell PV modules 0 Power Output Pm.x W p 330 335 340 345 Cell Orientation 60 cells(6x10) Maximum input DC voltage 48 V 60 V Module Efficiency % 17.9 18.2 18.5 18.7 Module Dimension 1748mm x 1054mm x 40mm Peak power tracking voltage 27 V-37 V 27 V-45 V m Operating range 16 V-48 V 16 V-60 V im Weight 20.3 kg(44.8lbs.) w Tolerance % 0/+3 0/+3 0/+3 0/+3 Min/Max start voltage 22 V/48 V 22 V/60 V Y Short Circuit Current Isc V 10.72 10.78 10.86 10.92 3.2mm,tempered,low-iron, U Front Glass P Max DC short circuit current(module Isc) 15 A 15 A w Open Circuit Voltage Voc A 40.40 40.58 40.82 41.00 anti-reflective Overvoltage class DC port II II c=� Rated Current Imp V 10.05 10.14 10.24 10.34 Frame Anodized DC port backfeed current 0 A 0 A Rated Voltage Vmp V 32.85 33.03 33.20 33.37 Encapsulant Ethylene vinyl acetate(EVA) PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; Fuse Rating A 20 20 20 20 Protection class IP67 AC side protection requires max 20A per branch circuit o Mo Junction Box OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter L cv System Voltage V 1000 1000 1000 1000 with 3 bypass-diodes m cal C:) c. Cable 1.0m,Wire 4mmz(12AWG) Peak output power 250 VA 295 VA 04 z c. Maximum continuous output power 240 VA 290 VA mLO ff"I In TWITRIT, Staubli PV-KBT4/611-UR and r -�:_ Connector Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208 V/ z w z Normal Operating Cell Temperature(NOCT) 44.43'C(±3.7%) PV-KST4/611-UR,MC4,Renhe 05-8 211-264 V 183-229 V 211-264 V 183-229 V 3:: t.:.i _J Temperature Coefficient of Pma. -0.361%/'C Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) o N o Temperature Coefficient of Voc -0.2625'o/'C Nominal frequency 60 Hz 60 Hz MSE3455X5T: 345WP, 60 CELL SOLAR MODULE Temperature Coefficient ofl,c 0.039%/°C CURRENT - VOLTAGE CURVE Extended frequency range 47-6811z 47-68Hz V AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms J Cells Temp.=25'C Maximum units per 20 A(L-L)branch circuits 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) --1 12 Incident Irrd.=1000 W/m2 Overvoltage class AC port III III U . CONDITIONS AC port backfeed current 18mA 18mA CD Maximum System Voltage 1,000Vdc 10 Incident z Irrd.=aoo w/m Power factor setting 1.0 1.0 1-4 Operating Temperature Range -40°C(407)to+85°C(185°F) ¢ Co s Power factor(adjustable) 0.85 leading0.85 lagging 0.85 leading 0.85 lagging ~ Co Maximum Series Fuse Rating20A d Incident Irrd.=eo0 w/m2 ( i ) "' 99 9 9"' 99 9 r O 6 EFFICIENCY @240 V @208 V @240 V @208 V Fire Safety Classification Type 1 3 Incident z Peak efficiency 97.6% 97.6% 97.5% 97.3% U Irrd.=400 W/m U) J Q 4 CEC weighted efficiency 97.0% 96.5% 97.0% 96.5% ¢ o 5600 Pa front and 4800 Pa back load ::A:� U U Ir Front&Back Load(UL Standard) Incident Irrd.=zoo W/m2 MECHANICAL DATA z O Tested to UL 61730 2 Iw Ambient temperature range -400Cto+650C(-40°Fto+1490F) -400Cto+650C(-40°Fto+1490F) H :� IL 00 Hail Safety Impact Velocity 25mm at 23 m/s 0 Relative humidity range 4%to 100%(condensing) W CO 0 '° m DC Connector type Staubli made MC4 W U = M Voltage M Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) H j c Current-voltage characteristics with dependence on irradiance Weight 1.1 kg(2.4 Ibs) UI C14 and module temperature Cooling Natural convection-No fans Z a t) W N" Approved for wet locations Yes W w BASIC DIMENSIONS(UNITS:mm) • Pollution degree PD3 O IEC 61215,61730,61701 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Or Cl- ILL 61730 Environmental category/UV exposure rating NEMA Type 6/outdoor z 1054----7 �1054 �I-aD FEATURES � Communication Power Line Communication(PLC) C CUD us t C Tw Monitoring Enlighten Manager and MyEnlighten monitoring options. suo Both options require installation of an Enphase IQ Envoy. LISTED Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect means required by NEC 690 and C22.1-2018 Rule 64-220. o1.0 77 Compliance CA Rule 21(UL 1741-SA) Mounting Hole UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, ' . CAN/CSA-C22.2 NO.107.1-01 as I I I I 1 as 17as Container FT Ship To Pallet Panels 345 W Bin This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017, 055 and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and Grounding Hole W) 53' Most states 34 884 304.98 kW DC conductors,when installed according manufacturer's instructions. Double Stack California 28 728 251.16 kW Pallet[26 Panels] Weight Height Width Length 1.No enforced DC/AC ratio.See the compatibility calculator at httos://enohase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 1263 lbs. 47.5 in 46 in 70.25 in 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. (573 kg) (120.65 cm) (116.84 cm) (178.43 cm) Note:Adapters 1 and 2 are qualified per UL subject 9703,Adapter 3 requires installers to field install their choice of connector. U Front View Side View Front View o it To learn more about Enphase offerings,visit enphase.com m Z©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7,Enphase IQ 7+,Enphase IQ Battery,EnphaseENPHASE J Enlighten, j Enphase IQ Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change.30-MAR-2021 zp m Mission Solar Energy reserves the right to make specification Mission Solar Energy 18303S.New Braunfels Ave.,San Antonio,Texas 78235 rr tit (/') changes without notice www.missionsolar.com I info@missionsolar.com o w o O to z U U N L� UJ U w CD MQ W J !Y C-., d Q DWG. NO. S-5 `11/111111// THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D. ����•o�,Ew•D, y�i,��� HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS \cEIVg�.<< DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE No 8747s SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. = * = STATE OF :4u�/ Enphase Q Cable Accessories Enphase IQ Combiner 3 MODEL NUMBER J Q AGGREGATOR SPECIFICATIONS IQ Combiner 3 IQ Combiner 3 with Enphase IQ Envoy"printed circuit board for integrated revenue grade PV = X-IQ-AM1 240-3 production metering(ANSI C12.20+/-0.5%)and optional*consumption monitoring(+/-2.5%). o Q Aggregator Q-BA-3-1P-60(single-phase).Combines up to three microinverter branches into one home run. ACCESSORIES and REPLACEMENT PARTS(not included,order separately) Protect with maximum 60 A,2-pole OCPD. r Q Commercial Aggregator Q-BA-3-3P-35(three-phase).Combines up to three,single-phase microinverter branches into a three- Enphase Mobile Connect" O7 phase home run.Protect with maximum 40 A,3-pole OCPD. CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 0 CELLMODEM-01(3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, Y Dimensions 190 mm(W)x 227 mm(D)x 80 mm(H)[7.5 in(W)x 9 in(D)x 3.2 in(H)] CELLMODEM-M1(4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) w Homerun conductor size range #12 to#4 AWG Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/-2.5%). C-) CT-200-SPLIT Enclosure rating NEMA3(up to 45°from horizontal) -Consumption monitoring is required for Enphase Storage Systems Ensemble Communications Kit Installed at the IQ Envoy.For communications with Enphase Encharge'storage and Enphase Temperature range 40°C to+55°C(40°F to+122°F) rh COMMS-KIT-01 Enpower"smart switch.Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner" C:) Compliance UL1741(assernbled product)and UL6703(bulkhead connectors) and allows wireless communication with Encharge and Enpower. N Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. °O 04 04 C:) N CONDUCTOR SPECIFICATIONS BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 r cn Certification UL3003(raw cable),UL 9703(cable assemblies),DG cable BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 z i�.i z Flame test rating FT4 3 �. � EPLC-01 Power line carrier(communication bridge pair),quantity-one pair o N o Compliance RoHS,OIL RES I,CE,UV resistant,combined UL for the United States XA-SOLARSHIELD-ES Replace the default solar shield with this Ensemble Combiner Solar Shield to match the look Conductor type THHN/THWN-2 dry/wet and feel of the Enphase Enpower'"smart switch and the Enphase Encharge'"storage system Disconnecting means The AC and DC bulhead connectors have been evaluated and approved by UL for use as the load-break XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) Q required b NEC 690. J disconnect re q y XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 --t Q CABLE TYPES/ORDERING OPTIONS ELECTRICAL SPECIFICATIONS r? V7 Model Number Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Z o Rating Continuous duty tJ 7 Q-12-10-240 277 VAC 1.3 m(4.2 ft) Portrait 240 I I System voltage 120/240 VAC,60 Hz Q-12-17-240 277 VAC 2.0 m(6.5 ft) Landscape(60-cell) 240 r Qp Eaton BR series busbar rating 125 A J ¢ U Q-12-20-200 277 VAC 2.3 m(7.5 ft) Landscape(72-cell) 200 Max.continuous current rating(output to grid) 65 A �' M ENPHASE Q CABLE ACCESSORIES Max.fuse/circuit rating(output) 90 A � Name Model Number Description LJ O rh Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Z Z w � -d- Raw Q Cable Q-12-RAW-200 300 meters of 12 AWG cable with no connectors Max.continuous current rating(input from PV) 64 A : 00 Field-wireable connector(male) LU CD Q-CONN-10M Make connections from any Q Aggregator open connector Max.total branch circuit breaker rating(input) 80 A of distributed generation/95 A with IQ Envoy breaker included W Field-wireable connector female r� ( ) Q-CONN-10F Make connections from any Q Cable open connector Envoy breaker 10A or 15A rating GE Q-line/Siemens Type QP/Eaton BR series included H LO U Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy Z a to Disconnect tool Q-DISC-10 Disconnect tool for Q Cable connectors,DC connectors,and AC module mount MECHANICAL DATA LL N W Q Aggregator sealing caps(male) Q-BA-CAP-10 Sealing cap for unused aggregator connections LU Dimensions(WxHxD) 49.5 x 37.5 x 16.8 cm(19.5"x 14.75"x 6.63").Height is 21.06"(53.5 cm with mounting brackets). CD Q Cable sealing caps(female) Q-SEAL-10 One needed to cover each unused connector on the cabling Weight 7.5 kg(16.5 Ibs) Terminator Q-TERM-10 Terminator cap for unused cable ends Ambient temperature range -400 C to+460 C(-400 to 1150 F) Z Replacement DC Adaptor(MC4) Q-DCC-2 DC adaptor to MC4(max voltage 100 VDC) Cooling Natural convection,plus heat shield Replacement DC Adaptor(UTX) Q-DCC-5 DC adaptor to UTX(max voltage 100 VDC) Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors TERMINATOR SEALING CAPS 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output: 10 to 2/0 AWG copper conductors Terminator cap for unused cable Sealing caps for unused aggregator Neutral and ground: 14 to 1/0 copper conductors ends,sold in packs often and cable connections Always follow local code requirements for conductor sizing. (Q-TERM-10) (Q-BA-CAP-10 and Q-SEAL-10) Altitude To 2000 meters(6,560 feet) INTERNET CONNECTION OPTIONS DISCONNECT TOOL CABLE CLIP Integrated WI-F! 802.111)/g/n Plan to use at least oine per Used to fasten cabling to the racking Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) installation,sold in packs often or to secure looped cabling,sold in(Q-DISC-10) packs of ten(Q-CLIP-1 00) Cellular CELLMODEM-M1 4G based LTE-M cellular modem(not included).Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. COMPLIANCE Compliance,Combiner UL 1741, CAN/CSA C22.2 No.107.1,47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 N z C:) it m To learn more about Enphase offerings,visit enphase.com I o learn more aDout tnpnase offerings,visit enon`Ise.com /1 ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. E N P H A S E ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 3,and other trademarks or service names are the ` E N P H A S E U (Dm 2018-01-03 `� trademarks of Enphase Energy,Inc.Data subject to change.2021-05-20 <n (/') Z L;.i O ¢ rn O cn z U li U w �O cm cm W DWG. NO. S-6 �►►1111111// THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D. ����•o�,Ew•D, y�i,��� HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS \cEIVg�.<< DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE No 8747s SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. = * = �:• STATE OF :4,u�/ Assembly 40RI'D N- its .' Ol ' • 1- Connection] 0 Corner out indmawk-,rray on roof. r Snap chalk lines for rail o location within shingle Y U course.(Refer to module = manufacturer frame clamping zones). Mark mounting locations o over rafters and chalk lines o U H N 04 within shingle course. °O z N Refer to engineering letters m for allowable mount spacing. 3 Q m Q N O For deck attachments,follow steps in 2a,but only use Splice Foot screws in the four corners of the mount. When possible always attach mounts to the rafter and only use deck attached as a secondary option when rafters are not within mounting zones for the array.Fallow K2 engineered calculations and span charts for deck attachments. J When deck attaching check for positive engagement into plywood and avoid plywood seams. Z o O r> H C) O Q O J 0 Q 00 1 START LU C' _ Using an additional piece of H r K2 butyl or a standard comp ,a rI Z � a M shingle starter course,level w Cn out the roof surface under the w z Splice Foot. o C'1 Cl- H For a video on mount leveling Z please refer to Splice Foot installation video:https:// www.youtube.com/c/ K2SystemsUSMX Locate the rafter and clean roofing surface for mount placement.Peel back protective paper from butyl,and stick down mount on a single shingle course with the two center holes lining up over the rafter.Position all mounts in the same direction with the long side towards the ridge.Drive provided lag screws into the rafter until the conical washer stops rotating,providing a positive seal.Do not over torque. N Z O U m Q U O m Of M (W Cn Z 4 N Q O <nGj z U U (n U w p p W J a:: cm a- U d < (n FDWG. N0. S-7 `11/111111// THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D. ����•o�,Ew•D, y�i,��� HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS \cEIVg�.<< DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE No 8747s SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. = * = 0: STATE OF :.4u�/ C-> 0 INA� J Sealant O application 0 Splicing two rails m 1 When connecting two rails to the Splice Foot,insert two T-Bolts through the Splice Foot slots and into side channel of CrossRail.Turn the T-Bolts clockwise ensuring that the mark at the end of the shaft is vertical, indicating proper alignment.Leave a 5/8"gap between rails in the center of the Splice Foot.Tighten to 25.8 ft- Ibs[35 Nm]. Note:Rail connector function for Splice Foot is only compatible with mill rail. 0 U o I C] N O N N Z N Ljj m Z O 3 �,..i z � 0 � I V Apply appropriate sealant to top and each side edge of mount,covering exposed butyl.No need to Proper T-Bolt Alignment � apply to the bottom of mount.If the mount falls on top of a shingle seam,fill and seal the seam with a Incorrect correct U) compatible roof sealant.If a seam comes within 2"of the lag screw,fill the seam with roof sealant. z o O C) H D co o O Q CC z w O H co W OALtaching single CrossRail LU J Z Ln Position and install rail on back side of Splice Foot towards the ridge,as shown in the image.Insert only one z cl- T-Bolt through one Splice Foot slot and into side channel of CrossRail.Turn the T-Bolt clockwise ensuring that w N the mark at the end of the shaft is vertical,indicating proper alignment.Tighten to 25.8 ft-Ibs[35 Nm]. z W o CI � H z .r ProperT-Bolt Alignment Incorrect Correct N Z CD fi U m Q U O < m Cn C/-) Z 6 O LLJ< rn O Q Cn z O O w O o L-I J Q' M d U Cl- Q (n M. NO. S-8 `11/111111// THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D. ����•o�,Ew•D, y�i,��� HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS \cEIVg�.<< DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE No 8747s SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. = * = STATE OF :4u�/ ��'�`�`• O Fi\Q P•Nam,. s,O N A X� Mounting systems for solar technology solar system o a Crossilail 48-X Technical Data Sheet 0 U Overview: U MECHANICAL PROPERTIES Material: 6000 Series Aluminum o 0 Ultimate Tensile Strength: 37.7 ksi(260 MPa) Cn N z N m Yield Strength: 34.8 ksi(240 MPa) Ljj o Weight: 0.56 lbs./ft.(0.833 kg/m) o o Finish: Mill or Dark Anodized v SECTION PROPERTIES —� J Sx: 0.199 in3(3.261 cm3) Z11 CDO Sy: 0.153 in3(2.507 cm3) �H A V-Section): 0.467 in2(3.013 cm2) jCOo U O Q General Dimensions: Z w O � H CO W 39 1 [4216.401— H Ln z 1.54 166 Z LU W z O [48] 1.89 0 Dimensions in [mm] Inches Notes: ► Structural values and span charts determined in accordance with Aluminum Design Manual and ASCE 7-10 ► UL2703 Listed System for Fire and Bonding U O C m LLJ Qodua w• U O CrossRail 48-X;Technical Data Sheet US1-0817 UL �(��1 Q m LLJ � V) C/') LISTED o w o 0 n < cn z z it U w o o w J d' d U Cl- Q (n W. NO. S-9