HomeMy WebLinkAboutPRODUCT APPROVAL 1120/22,3:39 PM Florida Building Code Online
I
i .
Business a Professional
BCIS Home Log In User Registration Hot TWes Submit Surcharge Stats&Facts Publications Contact Us BOS Site Map Links Search
bProduct
r Approval
IUSER:Public User
product APProval Menu>ProGutt or Application 5earch>ARohcation List>Appncatfon Detail
FL* FL13339-R9
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Attic Breeze
Address/Phone/Email 1370 FM 116
Gatesville,TX 76528
(254)865-9999
travis.hipp@atticbreeze.net
Authorized Signature Travis Hipp
travis.hipp@atticbreeze.net
Technical Representative Travis Hipp
Address/Phone/Email 1370 FM 116
Gatesville,TX 76528
(877)288-4234
travis.hipp@atticbreeze.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the James L. Buckner,RE, @ CBUCK Engineering
Evaluation Report
Florida License PE-31242
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration pate 12/01/2029
Validated By Steven M.Urich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL13339 R9 Col Cent of Independence James Buckner 202Q ds.pdf Standard and Year(of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
1708.2
https://floridabuilding.org/pr/pr_app_dU.aspx?param=wGEVXQwtDquFsbTbi%2b3jRWwJ%2bwxNAS%2bcivbtFg6fgmR5XFHjRonipw%3d%3d 113
1/20/22,3:39 PM Florida Building Code Online
Product Approval Method Method 2 Option B
Date Submitted 04/07/2021
Date Validated 04/11/2021
Date Pending FBC Approval 04/13/2021
Date Approved 06/08/2021
Summary,of Products
FL• Model,Number or Name Description
13339.1 01_Solar Attic Fan Models AB-2022A,AB-3022A,AB-4022A,AB-2523A,AB-
3523A,AB-4S23A Self-flashing,solar powered fan units,with
solar panel directly attached to fan unit shroud/dome
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL13339 R9 II 21-416 01 Attic Breeze-SPAF Panel Direct to
Approved for use outside HVHZ:Yes Flush Mount Unit ER-ds.gdf
Impact Resistant: No Verified By:James L. Buckner,P.E.@ CBUCK,Inc.P.E.*31242
Design Pressure: +115/-115 Created by Independent Third Party: Yes
Other: Refer to evaluation report for limitations and conditions Evaluation Reports
of use. Refer to manufacturer's installation Instructions as a FL13339 R9 AE 21-416 01 Attic Breeze-SPAF Panel Direct to
supplemental guide. Flush Mount Unit ER-ds.p_df
Created by Independent Third Party: Yes
13339.2 02_Solar Attic Fan Models AB-2022D,AB-3022D,AB-4022D,AB-6022D,AB-
2523D,AB-3523D,AB-4523D,AB-6523D&AB-1015.Self-
flashing,solar powered fan units,with solar panel(s)remotely
attached from fan unit,using low profile mounting brackets
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL13339 R9 II 21-416 02 Attic Bree a-SPAF Panel Remote to
Approved for use outside HVHZ:Yes Low Profile ER-ds.gdf
Impact Resistant: No Verified By:James L Buckner,P.E.@ CBUCK,Inc. P.E.*31242
Design Pressure: +115/-115 Created by Independent Third Party:Yes
Other: Refer to evaluation report for limitations and conditions Evaluation Reports
of use.Refer to manufacturer's installation instructions as a FL13339 R9 AE 21-416.02 Attic Breeze-SPAF Panel Remote
supplemental guide. to Low Profile ER-ds.pdf
Created by Independent Third Party:Yes
13339.3 03_Solar Attic Fan Models AB-2022D,AS-3022D,AB-4022D,AB-25231),AB-
35230,AS-4523D,Self-flashing,solar powered fan units,with
solar panel(s)remotely attached from fan unit,using universal
mounting bracket
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL13339 R9 II 21-416 03 Attic Breeze-SPAF Panel Remote
Approved for use outside HVHZ:Yes Inclined ER-ds.gdf
Impact Resistant: No Verified By:James L.Buckner,P.E. U CBUCK,Inc.P.E. *31242
Design Pressure: +115/-135 Created by Independent Third Party:Yes
Other: Refer to evaluation report for limitations and conditions Evaluation Reports
of use.Refer to manufacturer's installation Instructions as a FL13339 R9 AE 21-416 03 Attic Breeze-SPAF Panel Remote
supplemental guide. Inclined ER-ds.pl
Created by Independent Third Party:Yes
e13339.4 04 Curb Mount Series Curb Profile vent fan base for attad Trent to roof curbs.Sae
report for multiple Model numbers
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL13339 R9 II 21.416.04 Curb-SPA-CM-ER-cis.gd(
Approved for use outside HVHZ:Yes Verified By:James L Buckner,P.E.OCBUCK,Inc P.E. *31242
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: +115/-115 Evaluation Reports
Other: Refer to evaluation report for limitations and conditions FL13339 R9 AE 21-416.04 Curb-SPA-CM-ER-ds.gdj
of use. Created by Independent Third Party:Yes
back w—
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850<87-1824
The State of Florida is an AA/EE0 employer Coavriaht 2007-2013 State of Florida. ::Private Statement::Accesiblllty Statement::Refund Statement
Under Hands law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the onlm by phone or by traditional mall.it you have any questions,please contact 850.487.1395.'Pursuant to Seddon 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under chapter 455,F.S.must provide the department with an email address If may have One.The emalls
provided may be used far official communication with lye iterate.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine If you are a licensee under chapter 455,F.S.,please dick 0g .
Product Approved Accepts:
® ® ® `I.r
https://floridabuilding.org/pr/pr_app_d0.aspx?param--wGEVXOwtDquFsbTbi%2b3jRWwJ%2b=NAS%2bcivbtFg6fgmR5XFHJRonlpw%3d%3d 2/3
1120/22,3:39 PM Florida Building Code Online
Credit Card
Safe
https://floridabuilding.org/pr/pr_app_dtl.aspx7pammwGEVXQwtDquFsbTbi%2b3jRVVWJ%2bwxNA5%2bcivbtFg6fgmR5XFHJRonipwO/o3d%3d 3/3
CBUCK EnginL==rinq
Spe--ldlty Structural Engine-L-ring CBUCK,Inc.Certificate of Authorization#8064
Evaluation Report
Curb Mount Profile Base
Solar Powered Roof Ventilation
Appendix A
To Evaluation Reports: FL13339 .1 To .3
Manufacturer
Attic Breeze, LLC.
1370 FM 116
Gatesville, Texas 76528
(877) 288-4234
for
Florida Product Approval
# FL 13339.4 R9
Florida Building Code 7th Edition (2020)
Per Rule 61G20-3
Method: 2- B
Category: Roofing
Sub- Category: Roofing Accessories that are an Integral
Part of the Roofing System
Product Name: Curb Mount This item has been electronically signed and sealed
by lames L.Buckner,P.E.,on this date using a
Product Description: Curb Mount Series Digital Signature.Printed copies of this document
with Hood/Dome Mounted Solar Panel are not considered signed and sealed,and the
& Remote Mount Solar Panel signature must be verified on any electronic copies.
\\\I\1111111/I///
`\���E9 L. BUC��,�
Prepared by: �P.•' \GENgF' ..CCp
James L. Buckner, P.E., SECB No 91242
Florida Professional Engineer# 31242 (_
=1d ; W=
Florida Evaluation ANE ID: 1916 - 0 [t/,
T . STATE OF
Report No. 21-416.04-C-SPA-CM-ER %(C '•.,FLORIOP,.' C/'�
Date: 03/ 30/ 2021 '/'10NM-
Contents:
Evaluation Report Pages 1-6
2021 .03.30 22:11 :49 -04'00'
CBUCK, Inc. - Palm Beach County, Florida
Phone: (561)491-9927- Email:cbuck@cbuckinc.net-Website:www.cbuckinc.net
FL#: FL 13339.4 R9
Engineering Date: 03/30/2021
CBUCK En q q Report No.: 21-416.06-C-SPA-CM-ER
Page 2 of 6
speclalty structural Engineerinq CBUCK,Inc.Certificate of Authorization#8064
Manufacturer: Attic Breeze, LLC.
Product Name: Curb Mount Vent and Fan Base Models
Product Category: Roofing
Product Sub-Category Roofing Accessories that are an Integral part of the Roofing System
Compliance Method:
State Product Approval Rule 61G20-3.005 (2) (b)
Product Description:
Curb profile vent fan base for attachment to roof curbs. Curb material is the
same as the self flashing base in FL13339 Evaluation reports .1 to .4.
Product Assembly as
Evaluated: Curb profile base attached to roof curb designed by others.
Appendix A Scope:
This Appendix A is linked to FL13339 Reports .1 through .3
The vent units model numbers in this report are the same product specification
in Reports .1 to .3, including the same minimum base specifications.
This report .4 includes additional model numbers. The envelope
structural components are the same as previous reports. The differences
are internal mechanical and/or electrical.
This report addresses options for attaching the Curb Profile to roof curbs.
Model Numbers
Included in This Report:
GEN2 GEN3 Passive Vent
AB-2042A AB-2543A AB-1020
AB-3042A AB-3543A
AB-4042A AB-4543A
AB-2042D AB-2543D
AB-3042D AB-3543D
AB-4042D AB-4543D
AB-6042D AB-6543D
FL#: FL 13339.6 R9
Date: 03/30/2021
CBUCK Engineering ReportNo.: 21-416.06-C-SPA-CM-ER
Page 3 of 6
sp�_-cialtW structural Engineering CBUCK,Inc. Certificate of Authorization#8064
Vent Unit Curb Base Support: Type& Minimum Strength Specification :
Design of curbs is outside the scope of this evaluation
M Wood
Description:
15/32"or greater Plywood,or
Wood (based on minimum density/specific gravityof0.42)
2 Steel
22 gauge minimum thickness, 33 ksi minimum yield strength
(3)Aluminum
1/8 inch minimum thickness, alloy 6063-T52 or 6063-T6
Roof Slope: Slope shall be in compliance with FBC, Chapter 15 based on the type of roof covering.
Allowable Wind Resistance:
Performance: : Positive Design Pressure: +115 PSF
• Negative Design Pressure: -115 PSF
•Allowable design pressures for allowable stress design(ASD).
Performance Standards: The following test protocol was performed to demonstrate compliance with the
intent of the code as this product is not specifically addressed in the performance
standards listed in the code.
• ASTM E330-02—Standard Test Method for Structural Performance of Exterior
Windows, Curtain Walls, and Doors and by Uniform Static Air Pressure
Difference
Code Compliance: The product described herein has demonstrated compliance with the Florida
Building Code 7th Edition (2020),Section 1708.2.
FL M FL 13339.6 R9
Date: 03/30/2021
CBUCK Engineering Report No.: 21-416.06-C-SPA-CM-ER
Page 4 of 6
Speclalty structural Englneerinq CBUCK,Inc.Certificate of Authorization#8064
Evaluation Report Scope: This product evaluation demonstrates compliance of this product with the structural
wind load requirements of the Florida Building Code 7th Edition(2020), as related
to Florida Product Approval Rule 61G20-3.001.
Limits of Use: • Scope of"Limitations and Conditions of Use"for this evaluation:
This evaluation report for"Optional Statewide Approval'contains technical
documentation, specifications and installation method(s)which include
"Limitations and Conditions of Use"throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under"Optional Statewide Approval'.
• Option for application outside "Limitations and Conditions of Use"
Rule 61G20-3.005(l)(e) allows engineering analysis for "project specific
approval by the local authorities having jurisdiction in accordance with the
alternate methods and materials authorized in the Code". Any modification of
the product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the responsibility
of others.
Design of support system is outside the scope of this report.
Fire Classification is outside the scope of Rule 61G20-3,and is therefore not
included in this evaluation.
This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade& Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof vent products in accordance
with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a
quality assurance program audited by an approved quality assurance entity through
Keystone Certification, Inc. (FBC Organization#: QUA 1824)
FL M FL 13339.6 R9
Date: 03/30/2021
CBUCK Engineerinq ReportNo.: 21-416.06-C-SPA-CM-ER
Page 5 of 6
SpPclalty Structural EnglnPerinq CBUCK,Inc.Certificate of Authorization#8064
Component(s) Vent Base
Material Standards: Material Steel
Thickness: 22 ga•
Yield Strength: 33 ksi Minimum
Corrosion Resistance: Galvalume or Zincalume per ASTM A792 AZ 50
or in compliance with the FBC,Section 1507.4.3.
Fastener for Wood Curb
Type: Pancake or Hex Head Wood Screw
Size: #10 x 1 in. Minimum
Standard: Per ANSI/ASMEB18.6.1
Corrosion Resistance: Per FBC Section 1506.6
Fastener for Steel&Aluminum Curb
Type: Self Tapping or Self Drilling Screw
Size: #12 x 1 in. Minimum
Standard: Per FBC Section 1507.4.4 and/or SAE J78-1979
Corrosion Resistance: Per FBC Section 1506.6
Evaluated Referenced Data: 1. ASTM E330-02—Uniform Static Air Pressure DifferenceTest
By Certified Testing Laboratories, Inc. (FBC Organization ID#TST 1577)
Project#:CTLA 2002W, Dated: 11/20/09
2. Quality Assurance
By Keystone Certification, Inc. (FBC Organization ID#QUA 1824)
Attic Breeze, L-C. Licensee#740
3. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization#ANE 1916)
4. Engineering Analysis
By CBUCK Engineering
Report#17-144-EA, Dated: 6/11/17
FL#: FL 13339.6 R9
Date: 03/30/2021
CBUCK EnglnPl=rinq ReportNo.: 21-416.06-C-SPA-CM-ER
Page 6 of 6
Spxlalty structural EnglnPPrinq CBUCK,Inc.Certificate of Authorization#8064
Installation Methods
Attic Breeze, LLC.
Solar Powered Roof Vent Attachment To Curbs
Attach to Wood Curb:
Option to attach vertical leg or horizontal flange.
Screw: pancake head or hex head minimum#10 x 1
inch 3 screw on each side for a minimum total of 12.
Maximum spacing of 12 inches on center
and within 6 inches of corners
minimum distance to base edge 1 inch
Attach to Steel (22 gauge min.) or Aluminum ( 1/8 in min.) Curb:
Option to attach vertical leg or horizontal flange.
Screw: pancake head or hex
head minimum#10 x 1 inch
3 screws on each side for a minimum total of 12.
Maximum spacing of 12 inches on center
and within 6 inches of corners
minimum distance to base edge 1 inch