Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL 1120/22,3:39 PM Florida Building Code Online I i . Business a Professional BCIS Home Log In User Registration Hot TWes Submit Surcharge Stats&Facts Publications Contact Us BOS Site Map Links Search bProduct r Approval IUSER:Public User product APProval Menu>ProGutt or Application 5earch>ARohcation List>Appncatfon Detail FL* FL13339-R9 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Attic Breeze Address/Phone/Email 1370 FM 116 Gatesville,TX 76528 (254)865-9999 travis.hipp@atticbreeze.net Authorized Signature Travis Hipp travis.hipp@atticbreeze.net Technical Representative Travis Hipp Address/Phone/Email 1370 FM 116 Gatesville,TX 76528 (877)288-4234 travis.hipp@atticbreeze.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the James L. Buckner,RE, @ CBUCK Engineering Evaluation Report Florida License PE-31242 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration pate 12/01/2029 Validated By Steven M.Urich, PE Validation Checklist- Hardcopy Received Certificate of Independence FL13339 R9 Col Cent of Independence James Buckner 202Q ds.pdf Standard and Year(of Standard) Equivalence of Product Standards Certified By Sections from the Code 1708.2 https://floridabuilding.org/pr/pr_app_dU.aspx?param=wGEVXQwtDquFsbTbi%2b3jRWwJ%2bwxNAS%2bcivbtFg6fgmR5XFHjRonipw%3d%3d 113 1/20/22,3:39 PM Florida Building Code Online Product Approval Method Method 2 Option B Date Submitted 04/07/2021 Date Validated 04/11/2021 Date Pending FBC Approval 04/13/2021 Date Approved 06/08/2021 Summary,of Products FL• Model,Number or Name Description 13339.1 01_Solar Attic Fan Models AB-2022A,AB-3022A,AB-4022A,AB-2523A,AB- 3523A,AB-4S23A Self-flashing,solar powered fan units,with solar panel directly attached to fan unit shroud/dome Limits of Use Installation Instructions Approved for use In HVHZ:No FL13339 R9 II 21-416 01 Attic Breeze-SPAF Panel Direct to Approved for use outside HVHZ:Yes Flush Mount Unit ER-ds.gdf Impact Resistant: No Verified By:James L. Buckner,P.E.@ CBUCK,Inc.P.E.*31242 Design Pressure: +115/-115 Created by Independent Third Party: Yes Other: Refer to evaluation report for limitations and conditions Evaluation Reports of use. Refer to manufacturer's installation Instructions as a FL13339 R9 AE 21-416 01 Attic Breeze-SPAF Panel Direct to supplemental guide. Flush Mount Unit ER-ds.p_df Created by Independent Third Party: Yes 13339.2 02_Solar Attic Fan Models AB-2022D,AB-3022D,AB-4022D,AB-6022D,AB- 2523D,AB-3523D,AB-4523D,AB-6523D&AB-1015.Self- flashing,solar powered fan units,with solar panel(s)remotely attached from fan unit,using low profile mounting brackets Limits of Use Installation Instructions Approved for use In HVHZ:No FL13339 R9 II 21-416 02 Attic Bree a-SPAF Panel Remote to Approved for use outside HVHZ:Yes Low Profile ER-ds.gdf Impact Resistant: No Verified By:James L Buckner,P.E.@ CBUCK,Inc. P.E.*31242 Design Pressure: +115/-115 Created by Independent Third Party:Yes Other: Refer to evaluation report for limitations and conditions Evaluation Reports of use.Refer to manufacturer's installation instructions as a FL13339 R9 AE 21-416.02 Attic Breeze-SPAF Panel Remote supplemental guide. to Low Profile ER-ds.pdf Created by Independent Third Party:Yes 13339.3 03_Solar Attic Fan Models AB-2022D,AS-3022D,AB-4022D,AB-25231),AB- 35230,AS-4523D,Self-flashing,solar powered fan units,with solar panel(s)remotely attached from fan unit,using universal mounting bracket Limits of Use Installation Instructions Approved for use in HVHZ: No FL13339 R9 II 21-416 03 Attic Breeze-SPAF Panel Remote Approved for use outside HVHZ:Yes Inclined ER-ds.gdf Impact Resistant: No Verified By:James L.Buckner,P.E. U CBUCK,Inc.P.E. *31242 Design Pressure: +115/-135 Created by Independent Third Party:Yes Other: Refer to evaluation report for limitations and conditions Evaluation Reports of use.Refer to manufacturer's installation Instructions as a FL13339 R9 AE 21-416 03 Attic Breeze-SPAF Panel Remote supplemental guide. Inclined ER-ds.pl Created by Independent Third Party:Yes e13339.4 04 Curb Mount Series Curb Profile vent fan base for attad Trent to roof curbs.Sae report for multiple Model numbers Limits of Use Installation Instructions Approved for use In HVHZ:No FL13339 R9 II 21.416.04 Curb-SPA-CM-ER-cis.gd( Approved for use outside HVHZ:Yes Verified By:James L Buckner,P.E.OCBUCK,Inc P.E. *31242 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: +115/-115 Evaluation Reports Other: Refer to evaluation report for limitations and conditions FL13339 R9 AE 21-416.04 Curb-SPA-CM-ER-ds.gdj of use. Created by Independent Third Party:Yes back w— Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850<87-1824 The State of Florida is an AA/EE0 employer Coavriaht 2007-2013 State of Florida. ::Private Statement::Accesiblllty Statement::Refund Statement Under Hands law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the onlm by phone or by traditional mall.it you have any questions,please contact 850.487.1395.'Pursuant to Seddon 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under chapter 455,F.S.must provide the department with an email address If may have One.The emalls provided may be used far official communication with lye iterate.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under chapter 455,F.S.,please dick 0g . Product Approved Accepts: ® ® ® `I.r https://floridabuilding.org/pr/pr_app_d0.aspx?param--wGEVXOwtDquFsbTbi%2b3jRWwJ%2b=NAS%2bcivbtFg6fgmR5XFHJRonlpw%3d%3d 2/3 1120/22,3:39 PM Florida Building Code Online Credit Card Safe https://floridabuilding.org/pr/pr_app_dtl.aspx7pammwGEVXQwtDquFsbTbi%2b3jRVVWJ%2bwxNA5%2bcivbtFg6fgmR5XFHJRonipwO/o3d%3d 3/3 CBUCK EnginL==rinq Spe--ldlty Structural Engine-L-ring CBUCK,Inc.Certificate of Authorization#8064 Evaluation Report Curb Mount Profile Base Solar Powered Roof Ventilation Appendix A To Evaluation Reports: FL13339 .1 To .3 Manufacturer Attic Breeze, LLC. 1370 FM 116 Gatesville, Texas 76528 (877) 288-4234 for Florida Product Approval # FL 13339.4 R9 Florida Building Code 7th Edition (2020) Per Rule 61G20-3 Method: 2- B Category: Roofing Sub- Category: Roofing Accessories that are an Integral Part of the Roofing System Product Name: Curb Mount This item has been electronically signed and sealed by lames L.Buckner,P.E.,on this date using a Product Description: Curb Mount Series Digital Signature.Printed copies of this document with Hood/Dome Mounted Solar Panel are not considered signed and sealed,and the & Remote Mount Solar Panel signature must be verified on any electronic copies. \\\I\1111111/I/// `\���E9 L. BUC��,� Prepared by: �P.•' \GENgF' ..CCp James L. Buckner, P.E., SECB No 91242 Florida Professional Engineer# 31242 (_ =1d ; W= Florida Evaluation ANE ID: 1916 - 0 [t/, T . STATE OF Report No. 21-416.04-C-SPA-CM-ER %(C '•.,FLORIOP,.' C/'� Date: 03/ 30/ 2021 '/'10NM- Contents: Evaluation Report Pages 1-6 2021 .03.30 22:11 :49 -04'00' CBUCK, Inc. - Palm Beach County, Florida Phone: (561)491-9927- Email:cbuck@cbuckinc.net-Website:www.cbuckinc.net FL#: FL 13339.4 R9 Engineering Date: 03/30/2021 CBUCK En q q Report No.: 21-416.06-C-SPA-CM-ER Page 2 of 6 speclalty structural Engineerinq CBUCK,Inc.Certificate of Authorization#8064 Manufacturer: Attic Breeze, LLC. Product Name: Curb Mount Vent and Fan Base Models Product Category: Roofing Product Sub-Category Roofing Accessories that are an Integral part of the Roofing System Compliance Method: State Product Approval Rule 61G20-3.005 (2) (b) Product Description: Curb profile vent fan base for attachment to roof curbs. Curb material is the same as the self flashing base in FL13339 Evaluation reports .1 to .4. Product Assembly as Evaluated: Curb profile base attached to roof curb designed by others. Appendix A Scope: This Appendix A is linked to FL13339 Reports .1 through .3 The vent units model numbers in this report are the same product specification in Reports .1 to .3, including the same minimum base specifications. This report .4 includes additional model numbers. The envelope structural components are the same as previous reports. The differences are internal mechanical and/or electrical. This report addresses options for attaching the Curb Profile to roof curbs. Model Numbers Included in This Report: GEN2 GEN3 Passive Vent AB-2042A AB-2543A AB-1020 AB-3042A AB-3543A AB-4042A AB-4543A AB-2042D AB-2543D AB-3042D AB-3543D AB-4042D AB-4543D AB-6042D AB-6543D FL#: FL 13339.6 R9 Date: 03/30/2021 CBUCK Engineering ReportNo.: 21-416.06-C-SPA-CM-ER Page 3 of 6 sp�_-cialtW structural Engineering CBUCK,Inc. Certificate of Authorization#8064 Vent Unit Curb Base Support: Type& Minimum Strength Specification : Design of curbs is outside the scope of this evaluation M Wood Description: 15/32"or greater Plywood,or Wood (based on minimum density/specific gravityof0.42) 2 Steel 22 gauge minimum thickness, 33 ksi minimum yield strength (3)Aluminum 1/8 inch minimum thickness, alloy 6063-T52 or 6063-T6 Roof Slope: Slope shall be in compliance with FBC, Chapter 15 based on the type of roof covering. Allowable Wind Resistance: Performance: : Positive Design Pressure: +115 PSF • Negative Design Pressure: -115 PSF •Allowable design pressures for allowable stress design(ASD). Performance Standards: The following test protocol was performed to demonstrate compliance with the intent of the code as this product is not specifically addressed in the performance standards listed in the code. • ASTM E330-02—Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors and by Uniform Static Air Pressure Difference Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 7th Edition (2020),Section 1708.2. FL M FL 13339.6 R9 Date: 03/30/2021 CBUCK Engineering Report No.: 21-416.06-C-SPA-CM-ER Page 4 of 6 Speclalty structural Englneerinq CBUCK,Inc.Certificate of Authorization#8064 Evaluation Report Scope: This product evaluation demonstrates compliance of this product with the structural wind load requirements of the Florida Building Code 7th Edition(2020), as related to Florida Product Approval Rule 61G20-3.001. Limits of Use: • Scope of"Limitations and Conditions of Use"for this evaluation: This evaluation report for"Optional Statewide Approval'contains technical documentation, specifications and installation method(s)which include "Limitations and Conditions of Use"throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval'. • Option for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(l)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. Design of support system is outside the scope of this report. Fire Classification is outside the scope of Rule 61G20-3,and is therefore not included in this evaluation. This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade& Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof vent products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certification, Inc. (FBC Organization#: QUA 1824) FL M FL 13339.6 R9 Date: 03/30/2021 CBUCK Engineerinq ReportNo.: 21-416.06-C-SPA-CM-ER Page 5 of 6 SpPclalty Structural EnglnPerinq CBUCK,Inc.Certificate of Authorization#8064 Component(s) Vent Base Material Standards: Material Steel Thickness: 22 ga• Yield Strength: 33 ksi Minimum Corrosion Resistance: Galvalume or Zincalume per ASTM A792 AZ 50 or in compliance with the FBC,Section 1507.4.3. Fastener for Wood Curb Type: Pancake or Hex Head Wood Screw Size: #10 x 1 in. Minimum Standard: Per ANSI/ASMEB18.6.1 Corrosion Resistance: Per FBC Section 1506.6 Fastener for Steel&Aluminum Curb Type: Self Tapping or Self Drilling Screw Size: #12 x 1 in. Minimum Standard: Per FBC Section 1507.4.4 and/or SAE J78-1979 Corrosion Resistance: Per FBC Section 1506.6 Evaluated Referenced Data: 1. ASTM E330-02—Uniform Static Air Pressure DifferenceTest By Certified Testing Laboratories, Inc. (FBC Organization ID#TST 1577) Project#:CTLA 2002W, Dated: 11/20/09 2. Quality Assurance By Keystone Certification, Inc. (FBC Organization ID#QUA 1824) Attic Breeze, L-C. Licensee#740 3. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) 4. Engineering Analysis By CBUCK Engineering Report#17-144-EA, Dated: 6/11/17 FL#: FL 13339.6 R9 Date: 03/30/2021 CBUCK EnglnPl=rinq ReportNo.: 21-416.06-C-SPA-CM-ER Page 6 of 6 Spxlalty structural EnglnPPrinq CBUCK,Inc.Certificate of Authorization#8064 Installation Methods Attic Breeze, LLC. Solar Powered Roof Vent Attachment To Curbs Attach to Wood Curb: Option to attach vertical leg or horizontal flange. Screw: pancake head or hex head minimum#10 x 1 inch 3 screw on each side for a minimum total of 12. Maximum spacing of 12 inches on center and within 6 inches of corners minimum distance to base edge 1 inch Attach to Steel (22 gauge min.) or Aluminum ( 1/8 in min.) Curb: Option to attach vertical leg or horizontal flange. Screw: pancake head or hex head minimum#10 x 1 inch 3 screws on each side for a minimum total of 12. Maximum spacing of 12 inches on center and within 6 inches of corners minimum distance to base edge 1 inch Refer to manufacturer's installation instructions as a supplemental guide for attachment.