HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTS 1/20122,3:37 PM Florida Building Code Online
rrrr�
-rofessional Regulation �V1
BC1S Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search
F! TIC?
i Product Approval pr
USER:Public User
Product AQprOval Menu>Produqt or Apnliwhon Search>Aplicatig List>Application Detail
FL 0 FL21895-R3
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Sentry Building Innovations
Address/Phone/Email 1209 Orange Street Wilmington
New Castle, DE 19801
(604)612-5289
mseth@sentrybuilding.com
Authorized Signature Marsha Hallandsworth
Mhollandsworth@sentrybuilding.com
Technical Representative Marsha Hallandsworth
Address/?hone/Email 1209 Orange Street Wilmington
New Castle, DE 19801
(843)735-1773
Mhollandsworth@sentrybuilding.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underiayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity QAI Laboratories
Quality Assurance Contract Expiration Date 12/31/2023
Validated By Sohn W. Knezevich,PE
validation Checklist- Hardcopy Received
Certificate of Independence FI 21895 R3 COI 2020 01 COI NIEMINEN p-4f
Referenced Standard and Year(of Standard) Standard YoK
ASTM D1970 2015
ASTM D4533 2015
ASTM D4798 2011
ASTM D4869 2016
ASTM D5035 2011
FRSA/TRI,Sixth Edition 2018
UL1897 2015
Equivalence of Product Standards
Certified By
https://floridabuilding.org/pr/pr_app_dtl.aspx7param=wGEVXQwtDqufjj9QzTt6YQnnxswE3xiGMgKUcbCNFDmTePlhaxjkxW/%3d%3d 112
1/20122.3:37 PM Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 11/19/2020
Date Validated 11/23/2020
Date Pending FBC Approval 11/29/2020
Date Approved 02/09/2021
Date Revised 12/17/2021
Summary of Products
Fl.it Model,Number or Name Description
21895.1 Roofnado Synthetic Roofing Synthetic roofing underiayments
Underlayments
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL21895 R3 II 2020 11 19 FINAL SENTRY FL21895-R3.W
Approved for use outside HVHZ:Yes Verified By: Robert Nteminen PE-59166
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-97.5 Evaluation Reports
Other: 1.)Refer to ER Section 5 for Limits of Use.2.)The FI 21895 R3 AE 2020 11 19 FINAL SENTRY FL3895-
design pressure herein pertains to one underlayment assembly R3.0
for use in tile roof systems. Refer to ER Section 5.8.3. Created by Independent Third Party:Yes
o yr,t
Conned Us::2601 Blair Stone Road,Tallahassee FL 32399 phone:850-487-1824
The State of Florida is an AA/Em employer.Colt'rlaht 2007-2013 state of Florida.::privacy statement::Accessibility statement::Pefund statement
Under Flowda law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395. Pursuant to section 455.275(1),
Florida Statutes,enedive October 1,2012,Bcansees licensed under chapter 455,F.S.must provide the Department with an email address If they have one.The malls
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to Me public To detemilm if you arc a licensee under Chapter 45S,F.S.,please dick tom.
Product Approval Ampb:
®® ® Ei®
Credit Card
Safe
https:/Moddabuilding.orgtpr/pr_app_dtl.aspx?param=wGEVXQwtDg49QzTt6YQnnxswE3xiGMgKUc.bCNFDmTePlhayAbcrw%3d%3d 212
NEMO I etc.
Certificate of Authorization#32455
353 Christian Street,Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATIONP
Sentry Building Innovations Evaluation Report 13925.02.17-1-R3
1209 Orange Street,Wilmington, FL21895-113
New Castle, DE 19801 Date of Issuance:02/16/2017
(843)735-1773 Revision 3:11/19/2020
SCOPE:
This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance
with the 71h Edition(2020)Florida Building Code sections noted herein.
DESCRIPTION: Roofnado-Synthetic Roofing Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein
and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC,LLC of any changes
to the product(s),the Quality Assurance or the production facility location(s). NEMO ETC,LLC requires a complete review
of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADvEmIsENIENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through S.
Prepared by:
F= The facsimlle seals
Robert J.M.Nieminen,P.E. ??o a„off P/19/20was autdmsn samart
'' `-„ Nieminen,P.E.on ll/19/2030. Thisdces not serveazan
Florida Registration No.59166,Florida DCA ANE1983 su,a.,,,,�,•� el c ronirally signed document
CEFMRCATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02018,NEMO ETC,LLC
ONEMID etc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roofnado" Synthetic Roofing Underlayments, as produced by Sentry Building
Innovations,have demonstrated compliance with the following sections of the 11h Edition(2020)Florida Building
Code through testing in accordance with applicable sections of the following Standards. Compliance is subject to
the Installation Requirements and Limitations/Conditions of Use set forth herein.
STANDARDS:2.
Section Properties Standard Year
1504.3.1 Wind resistance UL 1897 2015
1507.1.1,1507.2.4,1507.2.9.2/ Material standard ASTM D1970 2015
R905.1.1,R905.2.8.2
1507.1.1.1(2&3,Exception), Tear strength ASTM D4533 2015
1507.1.1.1(5)/R905.1.1.1(2&3,
Exception),R905.1.1.1(5)
1507.1.1.1(2&3,Exception), Tensile strength ASTM D5035 2011
1507.1.1.1(5)/R905.1.1.112&3,
Exception),R905.1.1.1(5)
1507.1.1.1(5)/R905.1.1.1(S) Liquid water transmission ASTM D4869 2016
1507.3.3/R905.3.3 Material standard FRSA/rRI,Sixth Edition 2018
TAS 11O Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Entltv Examination Reference Date
NEMO Evaluation Report lm-ACr-19-F8CER.08.19-2-R2 11/19/2020
NEMO(TST6049) UL 1897 4L-ACr-18-002.07.18-2 07/05/2018
NEMO(TST6049) AC152 4S-ACr-18-001.10.18-18 10/08/2018
NEMO(TST6049) FRSA/TRI Manual 4S-ACT-18-001.11.18-28 11/12/2018
OAI(TM808) ASTM D1970 RJ5365P-3 04/26/2017
CIA](TSr9808) ASTM D1970(adhesion) R15365133 06/29/2017
CIA](QUA7628) Traceability/Inspections Service Confirmation 08/12/2019
CIA](QUA7628) Quality Assurance Florida BCIS Current
4. PRODUCT ► a
Product Material Standard Plant(s) Description
4.1 Roofnado" 1507.1.1.1(2&3,Exception), India Synthetic polymer-based scrim-reinforced underlayment,
AnchorDeck" 1507.1.1.1(5)/ consisting of woven polyolefin base with a layer of
R905.1.1.1(2&3,Exception), nonwoven polyolefin sheet and a polymer coating on the
R905.1.1.1(5) back side,with a nominal unit weight of 2.25 lbs/square.
4.2 RoofnaclWm 1507.1.1.1(2&3,Exception), India Synthetic polymer-based scrim-reinforced underlayment,
StormTread" 1507.1.1.1(5)/ consisting of woven polyolefin base with a layer of
R905.1.1.1(283,Exception), nonwoven polyolefin sheet and a polymer coating on the
R905.1.1.1(5) back side,with a nominal unit weight of 3.90 lbs/square.
4.3 Roofnado" 1507.1.1.1(2&3,Exception), India Synthetic polymer-based scrim-reinforced underlayment,
Shinglet.ock' 1507.1.1.1(5)/ consisting of woven polyolefin base with a layer of
R905.1.1.1(2&3,Exception), nonwoven polyolefin sheet and a polymer coating on the
R905.1.1.1(5) back side,with a nominal unit weight of 3.80 Ibs/square.
4.4 Roafnado" ASTM D1970& United Self-adhering underlayment consisting of a synthetic top-
LapLock' PSU FRSA/TRI 09-18 Arab facer,polymer modified bitumen and a release liner,
Emirates available in rolls 36-inch x 67-ft with a nominal 60-mil
thickness.
NEMO ETC,LLC Evaluation Report 13925.02.17-1-R3
Certificate of Aothori:ation#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL21895-R3
Roofnado"Synthetic Roofing Undedayments Revision 3:11/19/2020
Page 2 of 5
ONEMO etc.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Roofnado' Synthetic Roofing Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority
Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof
covering.
5.6 Allowable roof covers:
TABLE 1: RooF CovER OpnoNs
AC NOWIVRL• 1507.2 1307.3 1507Aa 1507.5 1507.7 1507AA 1907.9
Underlayment Asphalt
Clay and Concrete Tile Metal Slate or Wood
Mechanical Adhesive- Slate-Type
Shingles Attach Sat Panels Shingles shingles Shingles Shakes
Roofnado" Yes No No Yes Yes Yes No
AnchorDeckm (residential) (residential)
Roofnado" Yes No No Yes Yes Yes No
StormTread'"
Roofnado"' Yes No No Yes Yes Yes No
ShingleLock"'
nr Yes
LapLock"PSU Yes Yes Yes(see56.1) Yes Yes Yes (Iolnt strips,1507.1.1.3/
R905.1.L31
5.6.1 Adhesive-set tile is limited to use of following underlayment/tile adhesive combinations.
TABLE 3A:ALLOWABLE UNDERLAYMENT/TILE ADHESn1E COMBINATIONS'
Undedayment Adhesive Florida Product Approval
Roofnado'"LapLockm PSU ICP Adhesives"Polyseta AH-160" FL6332
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underayment ApplicationSubstrates(designed to meet wind loads for project)
Type Primer Matedal(s)
Roofnado"'LapLock"PSU self-adhering Deck/sheathing (Optional)ASTM D41 plywood or OSB
Base sheet None ASTM D226,Type II felt
'Refer to Tile Manufacture/s or Adhesive Manufacturer's Florida Product Approvoi far Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report L3925.0217.1-R3
CenlJkate ofAuthw4oNon N32455 7'"EDITION(2020)FBC NON-HVHZ EVALUATION FL21895-R3
Roofnado"Synthetic Roofing Undedaymems Revision 3:11/19/2020
Page 3 of 5
ONEMOletc.
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than F8C 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but not less than Section 5.8.3 herein.
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underiayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof rile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,Appendix A,Table lA or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-97.S osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional)ASTM D41
Underlayment: Roofnado'LapLock'PSU,self-adhered and back-nailed 12-inch D.C.
S.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment Prepared Roof Cover Installation Type Maximum Exposure(days)
Roofnado^ AnchorDeckw,Roofnado— Mechanically attached 30
StormTreadw or Roofnado—ShingleLock—
Adhesiveset tile 90
Roofnadow LapLock" PSU
Mechanically attached 90
S.10 The Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DEIX TILE INSTALLATIONS
Underlayment rile Profile Staging Method Maximum Sbpe
Roofnado' Laplock' PSU Flat or Lugged Max.10-tile stack 4:12
NEMO ETC,LLC Evaluation Report 13925.02.17-143
Cenificate ofAuthontntion#32455 7'"EDITION(2020)FBC NON-HVHZ EVALUATION FL2189S-R3
Roofnado"Synthetic Roofing Underlayments Revision 3:11/19/2020
Page 4 of 5
ONEIVIO etc.
6. INSTALLATION:
6.1 Roofrl Synthetic Roofing Underlayments shall be installed in accordance with the manufacturer's
published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted
below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application.
6.3 Roofnado"AnchorDeck",Roofnado"Stor nTread"or Roofnado"ShingieLodc":
6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception),
1507.1.1.1(3,Exception)or 1507.1.1.1(5)or FBC Residential R905.1.1.1(2,Exception),R905.1.1.1(3,Exception)
or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation
instructions. FBC requirements take precedence over the manufacturer's installation instructions.
6.3.2 Fasteners:
Minimum fasteners shall be corrosion resistant, ring-shank cap nails shall be as set forth in FBC 1507.1.1.1 or
1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3.
6.4 Roofnado"lapLodke'PSU:
6.4.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)
in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof
covering to be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type II felt,the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.4.2 Tile Applications:
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof rile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS:
Contact the named OA entity for manufacturing facilities covered by F.A.0 Rule 61G20-3 QA requirements.
Refer to Section 4 herein for products and production locations having met codified material standards.
8. QUAUTY ASSURANCE ENTITY:
QAI Laboratories—QUA7628;(604)527-8378,mlansdowne@Oai.orR
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 13925.02.174-113
Certificate ofAuthonmtion a32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL21895-R3
Roofnadc"Synthetic Roofing Underlayments Revision 3:11/19/2020
Page 5 of 5