HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET1. L ST. LUCIE ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Sic a Application A. B, C 1,2,3,4,5,6,7 Prescriptive SUR-RAS 150 A, B, C 2,4,5,6,7 i Asphaltic Shingles A, B, D 12,4.5.8,7 or Clay Tile A B� D, E t,2,3,4,5,BtZ� Metal oofs A. B, D 1,2,3,4,5,6,7 Woo nOng es and ,� 1,2,4,5,6,7 Shake Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1, Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5, Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation I Form RooftnfoFebll I Rev Feb 18. 2021 ST. LUCIE Section A (General Information) Master Permit No. Process No. Lice4'5 it Contractors Name: 5 c` T}t ef9j Roof �QV License It «c- tS 3 Z 3 N 47 Job Address 2 Z NW Ma r' C 7 M �'c ROOF CATEGORY ❑ low Slope O Mechanically Fastened Tile O Mortar/Adhesive Set Tiles ❑ Asphaltic Shingles fgfAetal Panel/Shingles OWood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE ❑ New roof Repair ❑ Maintenance L4`Reroofing 0Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area ( F) N Steep Sloped Roof Area (SF) I7 / f Total (SF) G 3 O 0 Section B (Roof Plan) Sketch Roof Plan-. III trate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of ections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ST. LUCIE Section C (Low S ope Roof) Fill in specific roof ssembly components and identify manufacturer (If a component is r ot used, Identify as "NA") System Manufactu r: Product Approval NO.: Design Wind Presst res, From RAS 128 Or Calculations: Zone 1': _ Zone 1 Zone 2: _Zone 3: _ Max. Design Press re, from the specific product a Fir system: Deck: Gauge Thick n ss: Slope: Anchor/Base Sheel & No. df Ply(s): Anchor/Base Sheel Fastener/Bonding M erial: Insulation Base Lai er: Base Insultation Si a and Thickness: Base Insulation Fa tener/Bonding Material: Top Insulation Lay r: Top Insulation Size and Thickness: Top Insulation Fas ener/Bonding Material: Base Sheets) & N . of Ply(s): Base Sheet Fasten ?r/Bonding Material: Ply Sheet(s)' & No of Ply(s): Ply Sheet Fastene /Bonding Material: Top Ply: Top Ply Fastener/ oncling Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_" oc @ Lap, N Rows_ ® _ 00 Zone 1:_" oc @ Lap, If Rows — ®" o0 Zone 2—" oc @ Lap, # Rows — @ " oc Zone 3_" oc @ Lap, # Rows— ® oc Number of Fasteners Per Insulation Board: Zone 1'—Zone 1_Zone 2—Zone 3:_ Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, shing, Continuous Cleat, Cant Strip, Base Flashing, Co t ashing, Coping, Etc. Ind' te: Mean Roof Height, Parapet Height, Height of Base ashi , Component Material, Material' Thickness, Fastener VType, Fastener Spacing or Submit Manufacturers Details that mply with RAS 1 11 and Chapter 16. FT. Parapet Height I FT. Mean Roof Height ST. LUCIE Section D (Steep Roof System Manufacti. Notice of Acceptance Minimum Design Wii Zone Roof Slope: 12 e Roof System) b�lnurn,-e nitk—u1S I ALL �;'74Cl-�j. I -.)-- Pressures, If Applicable (From RAS 127 or Calculations): -S'7Zone 2e: '!0' Zone 2n:� one 2r.-I � Zone 3e: Zone 3r: — Deck Type: Type Undedayment R, P t b- S , cq- — I Insulation '- Fife Barrier: y'+ Ridge Va jdati 7 Fastener Type & Spacing: +l/ ' Adhesive Type: Type Cap Sheet Mean Roof I leight: G Ve- Roof Covering: 3)4 C-R Type & Sias Drip Edge: ST. LUCIE Section E (Tile Calctj For Moment based 1 are greater than or Required Moment Mean Roof Heigh 2:12 3:12 4:12 5:12 6:12 7:12 'Must be used in c • For Uplift based ti equal to the Fr vale (Zone 1: x (Zone 2e: x (Zone 2n: x (Zone 2r: x (Zone 3e: x (Zone 3r: _x le systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mi. If the M, values equal to the M, values, for each area of the roof, then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T 1 _x l_= _)— Mg: _=Mn_ Product Approval M, 2e: _ x 1 `_ ) — Mg: _ = M,,, _ Product Approval M, 2n: _x.l_= _I —Mg; =M,a, Product Approval M, 2r: _xb= _)—Mg: =M,r, Product Approval Mi 3e: —x2'—= I — Mg: _= Mrs, ____ Product Approval M, 3c —xk-- _I — Mg: _=Mrs,_ Product Approval M, Method 2 "Simplified Tile Calculations Per Table Below" Resistance (Mr) From Table Below_=,Product Approval M, Mr required Moment 15' 20, 34.4 36.5 32.2 34.4 30.4 32.2 28.4 26.4 30.1 2 . — —30' 40' 39.7 42.2 37.4 39.8 _35.1_ 37.3 32.8 34.9 30.5 32.4 1 24.4 25.9 J 27.1 28.2 30.0 junction with a list of mo nt based the s tems systems use Method 3. Co pare the values for F' with the values for F, If the F' values are greater than or for each area of the roof, hen the the attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T _=x W:= ) -W: cos r F,r Product Approval F' =x W:= ) -W:_ cos r =Fo._ Product Approval F' _=x W:=) -W: cos r= F,m_ Product Approval F' =x W:= ) -W:_ cos r =F.z,_ Product Approval F' =x W:= ) -W: cos r Fne_ Product Approval F' x W:=) -W:_ cos r Fra,_ Product Approval F' Where to Obtain Information Description Symbol Where to find Design Pressure From applicable table in RAS 127 or by an engineering analysis B Zones 3, 2e, 2n, 2r, 3e, 3r prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope B Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due tc Gravity Mr Product Approval Attachment Resistance MI Product Approval Required Moment Resistance Mr_ Calculated rAverage un m Attachment R istance F' Product Approval uired Uplift Resistant F, Calculated — — Tile Weight W Product Approval Dimensions L = length W = width Product Approval All calculations must best bmitted to the building official at the time of permit application.