Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lynn & Andrew Stefanik Residence Builder Name: Street: Lot 44 River Pointe at the Sands Permit Office: St. Lucie County City, State, Zip: Ft. Pierce , FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (2290.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.0 1950.00 ft2 b. Frame -Wood, Exterior R=13.0 340.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2132.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2132.00 ft2 6. Conditioned floor area above grade (ft2) 2132 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A 11. Ducts R= ft2 R ft2 7. Windows(199.9 sqft.) Description Area a. Sup: Main, Ret: Main, AH: Garage 6 426.4 a. U-Factor: Dbl, U=0.28 199.90 ft2 SHGC: SHGC=0.29 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency - SHGC: a. Central Unit 47.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 47.0 HSPF:9.50 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.290 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor T Types (2132.0 sqft.) Insulation Area y EF: 0.990 a. Slab -On -Grade Edge Insulation R=0.0 2132.00 ft2 b. Conservation features b. N/A R= ft2 . None c. N/A R= ft2 15. Credits CF,.Pstat Glass/Floor Area: 0.094 Total Proposed Modified Loads: 58.60 PASS Total Baseline Loads: 58.70 I hereby certify that the plans ancNecifi ions eyed by Review of the plans and ST9?, this calculation are in compliance with the Florida nergy specifications covered by this Code. calculation indicates compliance PREPARED BY: ��lD��r/.�L L'N�ls �i LG/f with the Florida Energy Code. Before construction is completed DATE: `�/� /b this building will be inspected for compliance with Section 553.908 0 * "' I hereby certify that this building, as designed, is in compliance Florida Statutes. CAD with the Florida Energy C WE'D OWNER/AGENT: BUILDING OFFICIAL: DATE: 1 " �6 DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. COPY 4/7/2016 2:46 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4