Loading...
HomeMy WebLinkAboutProduct Approval - RoofingFlorida Building Code Online Page 1 of 2 Business & Professional ,u Regulation , BCIS:Home I Log In User Registration Hot Topic I Submit Surcharge Stats & Facts. I Publications I FBC Staff f BCIS Site Map I Links I Search A(Ma Departments I Busines Professi IProduct Approval ® USER:_ Public User Regulation Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL3506-118 NA Application Type Affirmation Code Version 2014 Application Status Approved Comments . Archived ❑ Product Manufacturer Hanson Roof Tile Address/Phone/Email 1340 SW 34 Ave Deerfield Beach, FL 33442 . (954) 421-2077 paul.oleksak@hanson.com Authorized Signature Paul Oleksak paul.dleksak@hanson.com Technical Representative Paul Oleksak -Address/Phone/Email Hanson Roof Tile 858 South Military Trail Deerfield Beach, FL 33442 (954)421-2077 Paul.oleksak@hanson.biz Quality Assurance Representative Paul Anderson Address/Phone/Email Hanson Roof Tile 230 West Davis Luling, TX 78648 (817) 690-8132 paul.anderson@hanson.com Category Roofing Subcategory Roofing Tiles Compliance Method Certification Mark or Listing Certification Agency Miami -Dade BCCO - CER Validated By Gary W. Walker ❑ Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard Year TAS 101 1995 TAS 102 1995 TAS 102(A) 1995 TAS 112 1 Equivalence of Product Standards Certified By D I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building. Code. https://www.floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtw2pk%2fDH... 3/ 15/2016 -5 Florida Building Code Online Page 2 of 2 Documentation from approved Evaluation or Validation Entity OYes ONo ON/A Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option A 02/03/2015 02/03/2015 02/08/2015 FL # - Model; Number or Name Description 3506.1 Hacienda Low/Medium Profile Roof Tile Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL3506 R8 C CAC FL3506 R6 II 12091,707 Hacienda Approved for use outside HVHZ: Yes Deerfield.Ddf Impact Resistant: N/A Quality Assurance Contract Expiration Date Design Pressure: N/A' " 12/16/2017 Other: Class A roof covering. Installation Instructions FL3506 R8 II 12091707 Hacienda Deerfield.Ddf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 3506.2 Hanson Flat Flat Profile Roof Tile Limits of Use Certification: Agency Certificate Approved for use in HVHZ: Yes FL3506 R8 C CAC 12 1218.14 Hanson Flat NOA.Ddf Quality Assurance Contract Expiration Date Approved for use outside HVHZ: Yes Impact Resistant: N/A 04/10/2018 Design Pressure: N/A Installation Instructions Other: Class A roof covering FL3506 R8 II 12 1218.14 Hanson Flat NOA.Ddf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 3506.3 Regal High Profile Roof Tile . Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL3506 R8 C CAC FL3506 R6 II 12091768 Regal Deerfield.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 12/16/2017 Other: Class A roof covering Installation Instructions FL3506 R8 II 12091708 Regal Deerfield.Ddf Verified By: Miami -Dade BCCO -. CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact Us :: 1940 North Monroe Street- Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO, employer. Copyright 2007-2013 State -of Florida.:: Privacy Statement Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® ;6 _ M . CreditCardSAFE https ://www. floridabuilding. org/prlpr_app_dtl. aspx?param=wGEVXQwtDgtw2pk%2fDH... 3/ 15/2016 MIAMI � MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474. T (786) 315-2590 F-(786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/sera Hanson Roof Tile 1340 SW 34`h Ave Deerfield Beach, FL 33442 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested' for quality assurance purposes.If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved -as described_ herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Hanson Hacienda Double Roll Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA, shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA- as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate- this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration datemay be displayed. in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A .copy of this entire. NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 11-1031.03 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. ►// NOA No.:12-0917.07 huarn•nE►oE couNnrAV Expiration Date: 12/16/17 Approval Date: 12/06/12 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system .using Hanson Hacienda Roof. Tile, as manufactured by Hanson Roof Tile in Deerfield Beach, Florida. and as described in Section 2 of this Notice of Acceptance. For the locations where the pressure requirements, do not exceed the values listed in section 4. herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION .Manufactured by Test Product Applicant Dimensions Specifications Description Hanson "Hacienda" Length: 17'/4" Low profile, interlocking, extruded concrete roof Width: 13" TAS 112 the equipped with two nail hole and double roll %a" thick ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Trim -Pieces 1= varies TAS 112 Accessory trim, concrete roof pieces for use at hips, w = varies rakes, ridges and valley terminations. varying thickness Manufactured for each tile profile. 2.1 MANUFACTURING LOCATION 2.1.1. Deerfield Beach, FL. 2.2 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Redland Technologies 7161-03 PA 102 - . Dec. 1991 7161-03 PA 102(A) Dec. 1991 7161-03 PA 108 Dec. 1991 P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails P0631-01 PA 108 July 1994 Letter Dated Aug. 1, 1994 PA 108 Aug. 1994 Professional Service Industries, 224-47099 PA 112 Sept. 1994 Inc. The Center for Applied 94-060B PA 101 March, 1994 Engineering, Inc. 94-084 PA 101 _ May-1994 25-7094-1 PA 102 Oct. 1994 25-7094-7 - PA 102 Oct. -1994 25-7094-4 PA 102 Oct. 1994 Project No. 307025 PA 100 Oct. 1994 Test #MDC-76 NOA No.: 12-0917.07 MLAMIDAOE couNTY Expiration Date: 12/16/17 Approval Date:.12/06/12 Page 2 of 6 2.2 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date 25-7183-1 PA 102 Feb. 1995 25-7183-2 PA 102 Feb. 1995 25-7214-2 PA 102 March, 1995 25-7214-6 PA 102 March, 1995 Celotex Corporation Testing 528454-24 PA 10.1 Sep. 1998 Services 520109-2 Dec. 1998 Walker Engineering, :Inc. Calculations Aerodynamic Multiplier March 1999 IBA Consultants, Inc. 2381-249 TAS 112 09/20/07 American Test Lab of South RT1024.01- 11 TAS 112 10/28/11 Florida 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar br adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with :TAS 112, appendix `A'. Such testing shall -be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications maybe installed perpendicular to the roof slope unless. stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. NOA No.:12-0917.07 MOLMUDADEcourvrr Expiration Date: 12/16/17 Approval Date:,12/06/12 Page 3 of 6 4. - INSTALLATION 4.1 Hanson `Hacienda' Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Hanson Hacienda Tile 10:0 1.4375 1.08 Table 2:. Aerodynamic Multipliers - X (ft3) Tile Profile a, (ft) Batten Application 2L (ft3) Direct Deck Application Hanson Hacienda. Tile 0.267 0.289 .Table 3: Restoring Moments due to Gravity --Mg (ft-Ibf) Tile Profilegreater 3": 12" 4": 12" 511: 12" 6": 12" 7": 12" or - Hanson Hacienda Tile Battens Direct Deck Battens Direct Deck Battens: Direct Deck Battens Direct Deck Battens Direct Deck - 5.92 - 6.80 5.82. 6.69 5.70 6.55 5.56 1 6.39 5.41 6.22, Table 4:. Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) For Nail -On Systems Tile .Profile Fastener Type Direct Deck (Min 16/32" plywood) Direct Deck (Min. 19/32" plywood) Battens Hanson 2710d Ring Shank Nails 27.8 37.4 28.8 Hacienda Tile 1-10d Smooth or Screw Shank Nail 8.8 11.8 4.1 2-10d Smooth or Screw Shank Nails 16.4 21.9 7.1 1 #8 Screw 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1-1.od Smooth or Screw Shank Nail field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails Field Clip) 35.5 35.6 34.8 2-10d Smooth or Screw Shank Nails Eave Clip) 31.9 31.9 32.2. 2-10d Ring Shank Nails 43.0 67.5 50.9 i Installation with a 4" tile' headlap and fasteners are located a min. of 2'h" from head of tile. NOA No.: 12-0917.07 QMIAM-DAIRCOUNnr Expiration Date: 12/16/17 Approval Date: 12/06/12 Page 4 of 6 Table 6:. Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Hanson Hacienda Tile Adhesive 26.1 2 See manufactures component approval for installation re Uirements. 3 Flexible Products Company TileBond Average weight per patty 11.4 grams. 3MTm 2-Component Foam.Roof Tile Adhesive AH-160. Average weight per patty 8 grams. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set. Systems Tile Profile Tile Application. Minimum.Attachment Resistance Hanson Hacienda Tile 3M 2-Com onent Foam Roof Tile Adhesive AH-160 86.61 3M 2-Component foam Roof Tile Adhesive AH-160 45.5 4 -Large piddyplacementof 54 rams 5 Medium add lacement of 24 grams Table 8: Attachment Resistance Expressed as a Moment- Mf(ft-lbf) for Mortar or Adhesive Set Systems Tile Tile Attachment Profile Application Resistance Hanson Hacienda Tile Mortar Set 20.6 S. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or following -statement: "Miami -Dade County Product Control Approved". nson. HANSON HACIENDA ROOF TILE .TILE IDENTIFICATION MARK LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance.: 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 12-0917.07 Expiration Date: 12/16/17 Approval Date: 12/06/12 Page 5 of 6 FA""""`Trr.rrdNT Tr PROFILE DRAWINGS HANSON HACIENDA CONCRETE ROOF TILE END OF THIS ACCEPTANCE [LOCK NOA No.: 12-0917.07 Expiration Date: 12/16/17 Approval Date: 12/06/12 Page 6 of 6