Loading...
HomeMy WebLinkAboutProduct ApprovalFlorida Building Code Online Page 1 of 3 FLORIDA. DePARTIVIGNT OF Business & Professional Regulation r Holida Department( BCIS Home I Log In I user Registration ; Hot Topics Submit Surcharge i Stats & Facts I Publications I FBC Staff .� BCIS Site Map I Links I Search Busines � s Product Approval Professi I R 0. USER: Public User Regulation Product Approval Menu > Product or Application Search > Application List > AppllcaUon Detail • FL # FL5027-R10 - Application Type Revision . Code Version 2014 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email GAF/LL Building, Products, Inc sub of GAF 295 McKoy Road Burgaw, NC 28403 (910) 663-3678, gblackwell@gaf.com Gordon Blackwell gblackwell@gaf.com Steve Boehling 295 McKoy Road Burgaw, NC 28425 sboehling@gaf.com Enrique Morales 295 McKoy Road Burgaw, NC 28425 emorales@gaf.com -Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity Miami -Dade BCCO - EVL Quality Assurance Entity Miami -Dade BCCO - CER Quality Assurance Contract Expiration Date 07/17/2017 - - Validated By Miami -Dade BCCO - VAL Certificate of Independence -Referenced. Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Standard Year TAS(100)(A) 1995 w- Product Approval Method Method 1 Option C https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtl VFscsiLIW... 3/15/2016 Florida Building Code Online Page 2 of 3 Date Submitted 10/14/2015 Date Validated 10/27/2015 Date Pending FBC Approval Date Approved 10/27/2015 FL # Model, Number or Name 5027.1 ARIOH Ridge Vent Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: . N/A . Design Pressure: N/A Other: AR1OH Ridge Vents shall not be installed on roof mean heights greater than 33 feet per Miami -Dade NOA 15- 0114.02. The AR10H Ridge Vent complies with the HVHZ of the Florida Building Code Description 10' long aluminum ridge vent - in embossed mill finish and colors Installation Instructions FL5027 R10 II NOA No 15-0114.02 AR1OH.odf Verified By: Miami -Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL5027 R10 AE NOA-No 15-0114.02 AR10H.odf 5027.2 GC12EF Turbine Vent 12" galvanized Turbine Roof Ventilator (externally braced in mill finish and in colors) Limits of Use Installation Instructions Approved for.use-in HVHZ: Yes FL5027 RIO II NOA NO 14-1224.14 GC12EF.odf Verified By: Miami -Dade BCCO - EVL Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: GC12EF Turbine Vents shall not be installed on roof FL5027 R10 AE NOA NO 14-1224.14 GC12EF.odf mean heights greater than 33 feet and these vents are approved for asphaltic shingle roofing per Miami -Dade NOA 14-1224.14: The GC12EF Turbine Vent complies with the HVHZ of the Florida Building Code. 5027.3 PR Solari/PR Hybridl Roof Mounted Solar Powered Attic Ventilator Limits of Use installation Instructions Approved for use'in HVHZ: Yes F1_5027 RIO II NOA NO 15-0812.18 PRSOLAR1 and PRHYBRID1.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Miami -Dade BCCO - EVL Design Pressure: N/A Created by Independent Third Party: Other: Approved for installations of asphaltic roofs with Evaluation Reports mean roof heights no greater than 33 feet per Miami -Dade FL5027 R10 AE NOA NO 15-0812.18 PRSOLARI and PRHYBRIDI.odf BCCO NOA 15-0812:18. The PR Solarl Roof Vent complies with the HVHZ of the Florida Building. Code . 5027.4 PRID Power Roof Vent Roof Mounted Powered Attic Ventilator Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5027 R10 II NOA NO 14-1224.15 PRiD Power Vent.odf Verified By: Miami -Dade BCCO - EVL Approved for use outside HVHZ: Yes Impact Resistant: N/A Created.by Independent Third Party: Design Pressure: N/A Evaluation Reports - Other: Approved.for installations of asphaltic roof with F1_5027. RIO AE NOA NO 14-1224.15 PR1D Power Vent.odf mean roof heights no greater than 33 feet per Miami -Dade BCCO NOA 14-1224.15. The PR1D Power Roof Vent complies with the HVHZ of the Florida Building Code 5027.5 PR2D Powered. Roof Vent PR2D Powered Roof Vent Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5027 RIO II NOA NO 14-1224.16 PR2D Power Vent.odf Verified By: Miami -Dade BCCO - EVL Approved for use outside HVHZ: Yes Impact Resistant: N/A- Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: Approved for installations of asphaltic roof with FL5027 RIO AE NOA NO 14-1224.16 PR2D Power Vent.odf mean roof heights no greater than 33 feet per Miami -Dade BCCO NOA 14-1224.16. The PR2D. Power Roof Vent complies with the HVHZ of the Florida Building Code 5027.6 PR3XD Powered. Roof Vent Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A.: Other: Approved for installations of asphaltic roof with mean roof heights no greater than 33 feet per Miami -Dade PR3XD Powered Roof Vent Installation Instructions FL5027 RIO II NOA NO 14-1224.17 PR3XD Power Vent.odf Verified By: Miami -Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL5027 RIO AE NOA NO 14-1224.17 PR3XD Power Vent. d h tps://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtlVFscsiLIW... 3/15/2016 Florida Building Code Online Page 3 of 3 BCCO NOA 1471224.17. The PR3XD Power Roof Vent complies with the HVHZ of the Florida Building Code 5027.7 SSB960 Static Roof Louver SSB960 Static Roof Louver Limits of Use Installation Instructions. Approved for use in HVHZ: Yes FL5027 -R10 II NOA NO 14-0414.08 SSB960 Slant Back Static Vent.Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Miami -Dade BCCO - EVL Design Pressure: N/A Created by Independent Third Party: -Other: SSB960 Roof Louvers shall not be installed on roof Evaluation Repots mean heights greater than 33 feet and are to be installed on FL5027 R10 AE NOA NO 14-0414.08 SSB960 Slant Back Static Vent.odf asphaltic shingle roofing per Miami -Dade NOA 14-0414.08. The SSB960 Static Roof Louver complies with the HVHZ of the Florida Building Code. Back Next Contact Us :: 1940.North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:; Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed, under Chapter 455, F.S. must provide. the Department with an email address if they have one. The emails provided may be used for official communication with the licensee: However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here_. Product Approval Accepts: -- ® `-tAec- E. CreditSCaarFE https://www.floridabuilding.org/pr/pr_app_dtl,aspx?paratn=wGEVXQwtDgtl VFscsiLIW... 3/15/2016 MIAMI-DADE COUNTY MIAWE PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami; Florida 33175-2474 BOARD AND CODE.ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted. by Miami -Dade County RER -Product. Control Section to be used in-Miam'Dade County and other areas -Where allowed by the. Authority Having.Jurisdiction (AHJ), This.NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County).and/or 'the AEU .(in areas. other than Miami. Dade County) . reserve the Tight .to have this productor material tested for quality assurance purposes. If this -product or material fails to perform in the accepted manner, . the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product -or material within their jurisdiction. RER reserves the right. to revoke this acceptance; if it is determined by Miami=Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as. described herein, and has been : designed to ' comply with the Florida Building Code including the High VelocityHurricane Zone of the Florida. Building Code. DESCRIPTION: GAF Master Flow® Attic Exhaust Vent —10ft. Aluminum Ridge Vent :(AR10H) LABELING: Each unit shall bear a permanent- label with, the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA. shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur .after theexpiration date. or if.there .has been a revision or change in -the materials, use; and/or manufacture of the product or process. Misuse of this NOA as an -endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall. be cause for termination. and removal .of NOA. ADVERTISEMENT: -The NOA number preceded by the words Miami -Dade County, -Florida, and followed by the expiration,date may be. displayed in advertising literature. If any portion of the NOA is displayed, then it. shall be done in its entirety. INSPECTION: A copy -of this entire NOA shall be.provided to the user by the manufacturer or its distributors and shall. be available for inspection at the. job site at the request of the Building Official. This NOA revises NOA.No. 12-0.127.10 and consists of pages 1 through 4 The submitted. documentation was reviewed by Alex Tigera. MIAMI•DADE COUNTY �FOHM...W NOA: No.: 15-0114.02 Expiration Date: 07/17/17 Approval Date: 08/20/15 Page 1 of 4 ROOFING SYSTEM APPROVAL • Category: - - Roofing Sub -Category: Ventilation Material:. Aluminum TRADE NAMES OF. PRODUCTS MANUFACTURED OR LABELED BY -APPLICANT: Test Product Product Dimensions Specification Description GAF Master Flow® Attic . 1.71": height _ TAS _100(A) Aluminum static louvered roof ventilation Exhaust Vent -10ft: 87.:width system Aluminum Ridge, Vent 10' aengtli - (AR10H) 0.025": Min. embossed thickness GAF. Master Flow® End 1.8": height TAS 100(A) . End cap for.GAF Master. Flow® Attic Exhaust Caps for -Aluminum 5.75":width Vent -1 Oft Aluminum Ridge Vent. (AR10H) . . • Ridge Vent -1.44"length - 0.080": Min. thickness GAF Master Flow® 4.5": height TAS l OO(A) Connector Strap for GAF Master Flow®Attic. . Connector Straps for - 2":width - . Exhaust Vent — IOft Aluminum Ridge, Vent Aluminum_ Ridge Vent 7.75":length . (AR1.OH) 0.025": Min -thickness MANUFACTURING LOCATION 1. Burgaw, NC. EVIDENCE SUBMITTED -_ Test Agency, Test Identifier Description -Date Center. for Applied Engineering, Inc.. MDC-106 TAS 100(A) Feb. 1995 Celotex Corporation Testing Services . 52012873 TAS 100(A) Jan. 1999 .PRI Construction Material LLB.-015-02--01 TAS 100.(A) - 08/01/07 Technologies. NOA No.: 154114.02 MLA► IDAoe couNTM Expiration Date: 07/17/17 Approval :Date: 08/20/15 Page 2 of 4 APPROVED ASSEMBLY: System Type A: Mechanical attachment of static vent over asphalt shingles. Cutout: Refer to manufacturer's published literature. Installation: Install endplug on the, end of the vent sealed with 100%silicone sealant. GAF Master Flow' Attic, Exhaust Vent —1 Oft. Aluminum Ridge Vent (AR10H) shall be 4" longer than ventilation slot to provide a base for the end plug. Apply'/4' wide bead of 1000% silicone sealant caulk to the bottom flange of the GAF Master Flow® Attic Exhaust Vent — IOft Aluminum. Ridge Vent (ARIOH) sections close to whereroof hole will be, after -vent is installed. Align end of first. section on the end.marks and the bottom -of the nailing. flange on'the chalk line (4" down on both side of the ridge peak). Nail the GAF Master Flow® Attic Exhaust Vent —10ft: Aluminum Ridge Vent. (AR10H) in place using 11/" aluminum ring shankroofing nails IT' o.c., with the first .nail .11/r" to 2:' from the vent end: All nail heads and vent section joints shall be sealed with 100% silicone sealant. Install GAF Master Flow® End Caps for Aluminum Ridge Vent over each end of ridge vent. Install GAF Master Flow® Connector Straps for Aluminum Ridge Vent at all connections between sections,.and at 3' intervals over the remainder of the vent using four 1'/2" aluminum ring shank - roofing nails per strap. Ventilation. Refer to manufacturer's published literature. Calculationk Minimum 2:.12 Slope: LIMITATIONS: 1. Refer to applicable Building Codes for required ventilation. 2. GAF Master Flow® Attic Exhaust Vent —1.Oft Aluminum Ridge Vent (AR10H). Shall comply with applicable building code. 3. GAF Master Flow® Attic Exhaust Vent —_ 1-Oft Aluminum Ridge Vent (AR10H) shall not be installed on roof mean heights greater than 33 feet. 4. GAF Master Flow° Attic Exhaust Vent —10ft Aluminum Ridge Vent (AR10H) shall comply with 1517.6 of the Florida Building -Code (FBC). 5. All:products = listed herein. shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 15-0114.02 M"bnAwe COUNTY Expiration Date: 07/17/17 Approval .Date: 08/20/15 Page 3 of 4 DETAIL GAF MASTER FLOW® ATTIC EXHAUST VENT - 10FT ALUMINUM RIDGE VENT (AR10H) END OF THIS -ACCEPTANCE CMIAMI-DWECO NOA: No.:. 15-0114.02 Expiration Date: 07117/17 Approval Date: 08/20/15 Page 4 of 4