Loading...
HomeMy WebLinkAboutExisting Plan View,i p Existing Plan View -IrkPaui i245 i a mass Road L 34947 it E't ' IMil .' i � 4 jt *, i l Maraldo Residence 10751 S. Ocean Dr., Lot B-5 Jensen Beach, FL 34957. Wilco Construction, Inc. Date: 10/15/21 (772)460-6928; FAX(772)460-6929 Pilings: TYPICAL DOCK AND ACCESSWAY CROSS SECTION Dock: min. 8" 0, (N.T.S.) wood 2.5 CCA max. 10, OC The work specified herein Boat Lift: has been designed and all 10" diam. +/-, wood work shall be in 2.5 CCA max. accordance with the 2020 Florida Building Code (7th Edn.). All codes reference herein Width: Varies are per the latest adopted edition. Decking: 2"x6" 0.4 ACQ #1 Tropical Decking STRINGERS: boards fastened whin. 3d" stainless steel 2"x8" 0.4 ACQ screws or 1 "x6" composite decking spaced at: max. 24" (for 2"x6" wood decking) OR fastened whin. 2.5" stainless max.18" (for 1"A" composite steel screws decking) with min. 5/8" SS lag bolts on each piling (lap spliced) NOTE: 147 Design loads to meet 2020 FBC - 7th Edn. Wind load as per ANSI/ /(2) ASCE 7-16 16d Toe Speodure D mph Nails Typical o f E N y j Importance Factor = 1.0 Block:Exp o+ To bE added as needed: Joist: 2"4" 12" 0.4 ACQ strap 2"x8" 0.4 ACQ on block @mid stringers each side of piling. 4 Permit Number •� -� (fast ed whin. 3 ea. Bolted w/ 5/8" 56-301691-004-EE � . min. "SS screws/nails ) SS cut rods. p Southeast District ,, y a vQ A d �ayss' 0 1S TSB •ply M.H.W. 3S p •�?,, �: -0 +t' M.L.W. CANAL BOTTOM 6' min. penetration Cross View Maraldo Residence- Wilco Construction, N Dock Structural Inc. N v 1 ENGINEERING REVIEW.• BOAT LIFT TOP CARRIER BEAMS AND MOUNTING BRACKETS COMPLY WITH WIND LOAD REQUIREMENTS OF THE 7TH EDITION (2020) FLORIDA BUILDING CODE, PER ASCE 7-16, AND PER DESIGN LOAD REQUIREMENTS OF THE 2015 EDITION ALUMINUM ASSOCIATIO ALUMINUM DESIGN MANL BEAMS AND MOUNTING BRACF INSTALLED PER HI -TIDE INSTRUCTION: EXCEED ULTIMATE DESIGN WIND SPEE 200 MPH (EXPOSURE CATEGORY C ( BOATS ARE TO BE REMOVED FROM 8 LIFTS PRIOR TO A MAJOR WIND EVE PILINGS: PILING PENETRATION TO BE 10' INTO THE SAND BOTTOM OR 5' INTO ROCK STRATA, SUB —SURFACE CONDITIONS CAN VARY GREATLY, THE CONTRACTOR SHALL VERIFY ALL PILE CAPACITIES TO COMPLY WITH FBC 202a ALL PILINGS TO BE 10" MINIMUM DIAMETER 2.5 C. C. A PRESSURE TREATED WOOD, PRE —STRESSED CONCRETE OR COMPARABLE EQUIVALENT. ELECTRICAL REVIEW. 1 HP ELECTRIC MOTOR -- AMPS ® 115V EACH 6.4 AMPS 0 230V EACH QUANTITY. 2 TOTAL WATTS: 2944 X2 E 2 HI 12.4 AM/'J V ZJUV LAGH QUAN77TY.• 2 TOTAL WATTS:• 5704 Digitally signed by Roger M BARER DN: r—US, o=Sustainable Earth L lEnngineers dba MCR Engineers, -ger Baber, P.E. o, u=A01_...4..10D0000017183ADA33 r C00001860sn=RogerM BABER Date: 2021.11.161255:07 -050W NOTE TO EXAMINER: THIS CERTIFIED ENGINEERED DRAWING HAS BEEN PREPARED SPECIFICALLY FOR USE ONLY BY.• WILCO CONST. opp6a00000Co00O0DOGOO m e ,9 °OOoo p CEIVs, O NO.43855 STATE OF 4f o0 0 ��8 4 O R 1 O oODOo $ 0 0 N A o a 9 ROGER BABER P.E. NO. 43855 CR PROFESSIONAL ENGINEERING 2430 NE DIXIE HWY JENSEN BEACH, FL 34957 ING MOUNTING TABS MUM (2) 3/8- DIA. SS LAG TS FOR WOOD PILING OR CONCRETE ANCHORS FOR 'CRETE PILINGS PER PILING IUIRED.MINIMUM (2) 3/8" SS CARRIAGE BOLT FOR ACHING MOUNTING TAB TO LIFT REQUIRED PER PILING. MOUNTING TAB CONSTRUCTED FROM 1/4- X 2" ALUMINUM 6 0 6 1 T 6 FLAT BAR. r7l" PVCWIDE POLES 4 PC BRAOCETS 4 K BRACKETS W HARDWARE 4 INUM BUNKS OR CARPETED a00D BUNKS 2 �^ BEAM ASSEMBLY 216, 000 LB. GEAR DRll/E & rJn� Tj (��� BOATLIFTS AND MARINE PRODUCTSC MOUNTING TABS IF REQUIRED B �/ /nLf( (/J/ TOP CARRIER SSEMBcr 1 p 4050 SELVITZ ROAD T TOP CARRIER AS SLY 1GEAR DRl1/E X2 BOAT LIFT (2020 FBC) X 3UMSSAC T7PE .NH SFiEAVE `+ FORT PIERCE, FL 34981 aLEC£AR2R. HYDE SCALE.• NTS DATE. 1/4/21 REV 1 -800-544-0735 www.hi-tide.com RIPON ar