Loading...
HomeMy WebLinkAboutNew Survey Pool RelocationGround Fault Circuit Breaker (For Pump) -- Water Proof / Ground Fault Circuit Breaker (located 6' - 20' frorn water) tSe��1"�tte �i5''t: tati Panel Time Clock Integral with pump AQUA RA DR Transformer Niche less Single Pole PAL Color TRIO fight Single Throw / (No Junction Box Required) Toggle switch / \\ or Wireless Remote NOTES: -ground all metal boxes. I -LED Niche -less light requires no ground. -Light fixture does not require GFCI or junction boss Electric Diagram Not To Scale I Surface Water Level 48 Solid bare cooperbond wire w/ approved Clamps r One on each side of the pool TOTAL: 4 Screwed Blown with 1.5" Long 1 /8 or larger approved concrete anchors N to \ Screwed Clown with 1.5" Long 1/8 or larger approved concrete anchors Pump & Filter Tie Top view / Not To Scale 18" min-24" max from inside wall og pool bonded to pool steel Equipotential Bonding Detail Per Florida Building Code Adaptation of N.E.C. 2008 sec680.26 Not To Scale Skimmer Vent Through Lid Water Level Deck Surface Pump Discharge ,(To Fitter) 2" PVC Pipe , Schedule 40 \ Pump Suction PB2008 Waterbond Fitting, Installed Sideways Horizontally attached to equipotential copper bond wire Per 20LZ NEC Section 680.26 (C) Listed 40YZ Pu p/Skim er Detail Not To Scale rn DRIVEWAY M \4 1. PLANS AND ENGINEERING ACCORDANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAI_ 2020, ANSI/NSPI 3, ANSI/NSPI 4, ANSI/NSPA 5, ANSI/NSPI 6, and ANSI/APSP 7. 2. ALL CONSTRUCTION AND INSTALLATIONS TO COMPLY WITH THE FLORIDA BUILDING CODE-: 7th EDITION RESIDENTIAL CODE 20207th EDITION, ANSI/NSPI 3, ANSI/NSPI 4, ANSI/NSPA 5, ANSI/NSPI 6, and ANSI/APSP 7. 3. ALL PIPING SHALL BE SCH 40 OR SCH 80 PVC, AND INSTALLATIONS SHALL BE COMPLY WITH FBC PLUMBING 2020. 4. ALL POOL AND SPA SHALL BE CONTINUOUS SOIL BEARING ON CLEAN COMPACTED SOIL WITH 2O00 PSF MINIMUM. 5. ALL HANDRAILS, LADDERS, LIGHTS SHALL BE BONDED WITH #8 GROUND WIRE PER NEC 680. 6. POOL AND SPA SHALL BE PROVIDED WITH APPROVED CHILD BARRIER OR SCREEN ENCLQSURE, HOUSE SAFETY BARRIER OR ALARM SYSTEM ALL IN ACCORDANCE WITH FBCR 4502.17.1 reference new survey to show revised location of pool and 7. ALL GAS AND FUEL PIPING SHALL BE PER FBC FUEL AND GAS 2020 (SEPARATE CONTRAC-rOR). compliance with all setbacks. 8. ALL ELECTRICAL INSTALLATIONS SHALL BE IN ACCORDANCE WITH THE CODE IN EFFECT AT THE CONSTRUCTION SITE. 9. POOL AND SPA EQUIPMENT SHALL BE SECURED TO CONCRETE PAD. 10. AFTER COMPLETION OF POOL CONSTRUCTION, HOMEOWNER SHALL CONSULT LICENSED POOL CONTRACTOR IN ORDER TO DRAIN POOL IF SO DESIRED. 11. HEATING EQUIPMENT SHALL COMPLY WITH FBC R 2020. 4 **Footers depicted =nthe site plan =ono=apply to this project. There will be no perimeter footer, just mudset pavers. 69 2' I I `D I i '61 I Existing RResidenceROPOSED OLND PAT10 1�` �� w Of 1,4iv 38 VERED AREA AVER BRICK PATIO SITE PLAN SCALER "=10' Concrete Min :500 Psi 2 ZL_L_:: 1-#5 Rebar Cobtinuous 36" Lap Splice ncrete Screen Footer Data' loatinZ or Pavers Not to Scal Concrete Min 2,500 Psi Reb Cobtinuous 36" Lap Sp Concrete Screen Footer Detail -Monolithic Slab. Not to Scale I ' "min Concret Foote Detail No S een Not tdscale LEGEND: SK Skimmer PR Pool Return KK Suction Cleaner Line EQUIPOTENTIAL BOND #8 BARE COPPER GROUND WIRE TO ELECTRICAL COMPONENTS AT EQUIPMENT r \ 2" Socket VGB 2008 Compliant 175 gpm Main Drain Plumbing Detail Not To Scale Specifications DIRECT BURIAL GROUND CLAMPS 4 AT CORNERS 0 0 0 0 [ PLUMBING DETAIL ELECTRIC BOND, SAFETY FENCE, REBAR DETAIL SAFETY FENCE 48", 360 PERIMETER, 3' CENTERS, 2' FROM WATER LINE 0 1 0 0 U 1 0 1 o 1 o / o o I o I o I o Eel 0 0 0 0 #3 J-SHAPED REBAR, 3' LENGTH @ 2' CENTERS, 360" PERIMETER OF POOL Pool Model: Clearwater bimen5ion5; 1 1'X20' Surface Area: 220SF Perimeter; 62' Light: 100W Total Wags; 100 Pooh Returns: 4 Capacity ( gals) : 6994 1" watertight, underground PVC VAC Stubout: Approved VAC Lock Fitting -turnover rate ( minutes) ; conduit back to 120V AC/12V AC 300 minutes transformer location, no junction Interior Finish: FIBERGLASS WITH GEL COAT box. All fittings should be glued Pump #1 : ha ward max flo Pump #2' NA and watertight hay ward Filter 5auare Footage, NA NA in, pipe Pool Main Brain connecting pipe NA in, pipe 5pa Main Brain connecting pipe EQUIPMENT PAD NA in, pipe 5pa 1�erapL{ 5uction �- *Minimum of 3 1/2" of straight, 1 1/2" PVC 2 in. pipe 5uction Cleaner Line OWNER:. pipe behind wall fitting required prior to conduit reducer or bend. �_ n, ipipe pool Skimmer dine p p ENGLERT, BARRETT 2 in. pipe Pool PAurn Line POOL CONTRACTOR: No -Niche LED Light .Detail NA in. pipe 5 a I;etur Line p p p GEOFFROY GEOFF P HILAIRE ( ) Not To Scale PAu�_v,,E CH INC. NA in. pipe Pool Then Peturn Line All America Pools Inc MECH-ELECT-CIVIL ENG, 1984 BILTMORE ST. #114 NA in. pipe 5pa Hier Peturn Line 5506 Melville Rd PORT SAINT LUCIE, FL 34984 ✓ Fort Pierce FL 34982 I'AUL WELCH R.E. FLA REG NO.29945 Phone: (772) DIG -POOL (344-7665) �NGIN��P C�PTI�IC TION Uric-Cour Florida Certified Pool Perrni«nr,, Contractor CPC-057355 Legal Information WINJMIUU VLL&j� !3Y TNF 5�A UNIfTWO Parcel #4511-811-0022-240-5 (UOf 4 CLU5T�P 2) FPOM 51� COP AUK � PUN N 00 b�G I� 47 AQUA RA DR JENSEN BEACH, FL 34957 MIN 105FC W 211,01 Pf f0 PC OF CUPV�