HomeMy WebLinkAboutNew Survey Pool RelocationGround Fault
Circuit Breaker
(For Pump) --
Water Proof /
Ground Fault Circuit Breaker
(located 6' - 20' frorn water)
tSe��1"�tte �i5''t: tati
Panel
Time Clock
Integral with pump
AQUA RA DR
Transformer
Niche less
Single Pole PAL Color TRIO fight
Single Throw / (No Junction Box Required)
Toggle switch / \\
or Wireless Remote
NOTES: -ground all metal boxes.
I -LED Niche -less light requires no ground.
-Light fixture does not require GFCI or junction boss
Electric Diagram
Not To Scale
I
Surface
Water Level
48 Solid bare
cooperbond
wire w/ approved
Clamps r One on each
side of the pool
TOTAL: 4
Screwed Blown with 1.5"
Long 1 /8 or larger approved
concrete anchors
N
to
\ Screwed Clown with 1.5"
Long 1/8 or larger approved
concrete anchors
Pump & Filter Tie
Top view / Not To Scale
18" min-24" max
from inside wall og pool
bonded to pool steel
Equipotential Bonding Detail
Per Florida Building Code Adaptation of
N.E.C. 2008 sec680.26
Not To Scale
Skimmer
Vent Through Lid
Water Level
Deck Surface
Pump Discharge
,(To Fitter)
2" PVC Pipe
,
Schedule 40 \ Pump
Suction
PB2008 Waterbond
Fitting, Installed
Sideways Horizontally
attached to equipotential copper bond wire
Per 20LZ
NEC Section 680.26 (C)
Listed 40YZ
Pu p/Skim er Detail
Not To Scale
rn
DRIVEWAY
M
\4
1. PLANS AND ENGINEERING ACCORDANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAI_
2020, ANSI/NSPI 3, ANSI/NSPI 4, ANSI/NSPA 5, ANSI/NSPI 6, and ANSI/APSP 7.
2. ALL CONSTRUCTION AND INSTALLATIONS TO COMPLY WITH THE FLORIDA BUILDING CODE-: 7th EDITION
RESIDENTIAL CODE 20207th EDITION, ANSI/NSPI 3, ANSI/NSPI 4, ANSI/NSPA 5, ANSI/NSPI 6, and ANSI/APSP 7.
3. ALL PIPING SHALL BE SCH 40 OR SCH 80 PVC, AND INSTALLATIONS SHALL BE COMPLY WITH FBC PLUMBING 2020.
4. ALL POOL AND SPA SHALL BE CONTINUOUS SOIL BEARING ON CLEAN COMPACTED SOIL WITH 2O00 PSF MINIMUM.
5. ALL HANDRAILS, LADDERS, LIGHTS SHALL BE BONDED WITH #8 GROUND WIRE PER NEC 680.
6. POOL AND SPA SHALL BE PROVIDED WITH APPROVED CHILD BARRIER OR SCREEN ENCLQSURE,
HOUSE SAFETY BARRIER OR ALARM SYSTEM ALL IN ACCORDANCE WITH FBCR 4502.17.1
reference new survey to show revised location of pool and 7. ALL GAS AND FUEL PIPING SHALL BE PER FBC FUEL AND GAS 2020 (SEPARATE CONTRAC-rOR).
compliance with all setbacks. 8. ALL ELECTRICAL INSTALLATIONS SHALL BE IN ACCORDANCE WITH THE CODE IN EFFECT AT THE CONSTRUCTION SITE.
9. POOL AND SPA EQUIPMENT SHALL BE SECURED TO CONCRETE PAD.
10. AFTER COMPLETION OF POOL CONSTRUCTION, HOMEOWNER SHALL CONSULT LICENSED
POOL CONTRACTOR IN ORDER TO DRAIN POOL IF SO DESIRED.
11. HEATING EQUIPMENT SHALL COMPLY WITH FBC R 2020.
4
**Footers depicted =nthe site plan =ono=apply to this project. There will be no perimeter
footer, just mudset pavers.
69 2'
I
I
`D I
i
'61
I
Existing RResidenceROPOSED OLND PAT10
1�`
��
w
Of 1,4iv
38
VERED AREA
AVER BRICK PATIO
SITE PLAN
SCALER "=10'
Concrete Min :500 Psi 2
ZL_L_::
1-#5 Rebar Cobtinuous
36" Lap Splice
ncrete Screen Footer
Data' loatinZ
or Pavers
Not to Scal
Concrete Min 2,500 Psi
Reb Cobtinuous
36" Lap Sp
Concrete Screen Footer
Detail -Monolithic Slab.
Not to Scale
I
' "min
Concret Foote Detail
No S een
Not tdscale
LEGEND:
SK Skimmer
PR Pool Return
KK Suction Cleaner Line
EQUIPOTENTIAL BOND
#8 BARE COPPER
GROUND WIRE
TO ELECTRICAL COMPONENTS
AT EQUIPMENT
r
\ 2" Socket
VGB 2008 Compliant
175 gpm Main Drain Plumbing Detail
Not To Scale
Specifications
DIRECT BURIAL
GROUND CLAMPS
4 AT CORNERS
0
0
0
0
[ PLUMBING DETAIL
ELECTRIC BOND, SAFETY FENCE, REBAR DETAIL
SAFETY FENCE 48", 360 PERIMETER,
3' CENTERS, 2' FROM WATER LINE
0
1 0
0 U 1 0 1 o 1
o / o o I o I o I o
Eel
0
0
0
0
#3 J-SHAPED REBAR, 3' LENGTH @ 2' CENTERS,
360" PERIMETER OF POOL
Pool Model: Clearwater bimen5ion5; 1 1'X20'
Surface Area: 220SF Perimeter; 62'
Light: 100W Total Wags; 100
Pooh Returns: 4 Capacity ( gals) : 6994
1" watertight, underground PVC VAC Stubout: Approved VAC Lock Fitting -turnover rate ( minutes) ;
conduit back to 120V AC/12V AC 300 minutes
transformer location, no junction Interior Finish: FIBERGLASS WITH GEL COAT
box. All fittings should be glued Pump #1 : ha ward max flo Pump #2' NA
and watertight hay
ward
Filter 5auare Footage, NA
NA
in, pipe Pool Main Brain connecting pipe
NA
in, pipe 5pa Main Brain connecting pipe
EQUIPMENT PAD
NA
in, pipe 5pa 1�erapL{ 5uction
�- *Minimum of 3 1/2" of straight, 1 1/2" PVC
2
in. pipe 5uction Cleaner Line
OWNER:.
pipe behind wall fitting required prior to
conduit reducer or bend.
�_
n,
ipipe pool Skimmer dine
p p
ENGLERT, BARRETT
2
in. pipe Pool PAurn Line
POOL CONTRACTOR:
No -Niche LED
Light .Detail
NA
in. pipe 5 a I;etur Line
p p p
GEOFFROY GEOFF P HILAIRE
( )
Not To Scale PAu�_v,,E CH INC.
NA
in. pipe Pool Then Peturn Line
All America Pools Inc
MECH-ELECT-CIVIL ENG,
1984 BILTMORE ST. #114
NA
in. pipe 5pa Hier Peturn Line
5506 Melville Rd
PORT SAINT LUCIE, FL 34984
✓
Fort Pierce FL 34982
I'AUL WELCH R.E.
FLA REG NO.29945 Phone: (772) DIG -POOL (344-7665)
�NGIN��P C�PTI�IC TION Uric-Cour Florida Certified Pool
Perrni«nr,, Contractor CPC-057355
Legal Information WINJMIUU VLL&j� !3Y TNF 5�A UNIfTWO Parcel #4511-811-0022-240-5
(UOf 4 CLU5T�P 2) FPOM 51� COP AUK � PUN N 00 b�G I� 47 AQUA RA DR JENSEN BEACH, FL 34957
MIN 105FC W 211,01 Pf f0 PC OF CUPV�