Loading...
HomeMy WebLinkAboutTotal Dynamic Calculation� � 1 PROJECT NAME: PROJECT ADDRESS: BARRETT ENGLERT POOL 47 AQUA RA DR JENSEN BEACH, FL TOTAL DYNAMIC HEAD (TDH) CALCULATION DETERMINE MAXIMUM FLOW RATE PER ANSI / ASPS -15 MINIMUM FLOW RATE REQUIRED: 35 gpm /SKIMMER 1 SKIMMER PER 800 ftZ OF SURFACE AREA POOL VOLUME _ = 6994 gal TURNOVER TIME = 5 hr X 60 min./hr MAXIMUM FLOW RATE = POOL VOLUME / TURNOVER SPA FLOW RATE = 23.3 gpm MAX 300 min. = 23.3 gpm PIPE SIZES AT MAXIMUM SYSTEM FLOW RATE BRANCH PIPING SHALL BE N/A inch AT 6 fps MAX AT #N/A gpm TRUNK PIPING SHALL BE 2 inch AT 8 fps MAX AT 84 gpm RETURN PIPING SHALL BE 2 inch AT 10 fps MAX AT 105 gpm PUMP MAKE/TYPE HAYWARD MAXFLO VS SP2303VSP MAIN DRAIN / COVER n/a SIGNATURE / DATE CONTRACTOR: CERT. # APPROVED COVER RATE REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC J/ SIGNATURE / DATE ALL AMERICAN POOLS INC. PAUL WELCH INC. CPC 057355 PAUL WELCH P.E. Sheet 1 of 3 CERT# 29945 n/a gpm � C W ., - No.29945 STATE OF .' 10. PROJECT NAME: BARRETT ENGLERT POOL PROJECT ADDRESS: 47 AQUA RA DR JENSEN BEACH, FL TOTAL DYNAMIC HEAD (TDH) CALCULATION WORKSHEET DETERMINE MAXIMUM FLOW RATE PER ANSI / ASPS -15 2013 FRICTION LOSS FOR 2 inch SUCTION PIPE PER ft AT FRICTION LOSS FOR 2 inch RETURN PIPE PER ft AT 75 ft. SUCT. PIPE X 0.10 ft HEAD / ft 65 ft. RETURN PIPE X 0.16 ftHEAD / ft 84 gpm = 0.10 ft (PER TABLE) 105 gpm = 0.16 ft (PER TABLE) 7.5 TDH FOR SUCT. PIPE = 10.4 TDH FOR RETURN PIPE TABLE: SMOOTH PIPE SCH 40 PVC / FLOW AND FRICTION LOSS PFR FT PIPE DIAMETER (in) 6 ft/sec 8 ft/sec 10 ft/sec 1 16 gpm 0.13 ft 22 gpm 0.23 ft 27 gpm 0.35 ft 1.5 38 gpm 0.08 ft 51 gpm 0.14 ft 63 gpm 0.21 ft 2 63 gpm 0.06 ft 84 gpm 0.10 ft 105 gpm 0.16 ft 2.5 90 gpm 0.05 ft 119 gpm 0.08 ft 149 gpm 0.13 ft 3 138 gpm 0.04 ft 184 gpm 0.07 ft 230 gpm 0.10 ft 4 238 gpm 0.03 ft 317 gpm 0.05 1 ft 1 397 1 gpm 1 0.071 ft \C ENS No. 29945 STATE OF0. �`�,��......••- �Ns.��` r Y%`� 821 SIGNATURE / DATE SIGNATURE / DATE CONTRACTOR: ALL AMERICAN POOLS INC. PAUL WELCH INC. CERT. # CPC 057355 PAUL WELCH P.E. Sheet 2 of 3 CERT# 29945 t PROJECT NAME: PROJECT ADDRESS: BARRETT ENGLERT POOL 47 AQUA RA DR JENSEN BEACH, FL fJlazFlo VS.i?eifaisita�e�Gn awV iYk �ba.: r1 �- :.Y':. .. .. .6�,., f tt : �>. r< s ♦yy�yy,�;�� 3 ! TDH IN PIPING: 17.9 ft FILTER LOSS IN TDH: 8.0 ft HEATER LOSS IN TDH 0.0 ft OTHER LOSSES IN TDH: 0.0 ft �n�uirrru TOTAL SIMPLIFIED TDH: 25.9 ft NOTES: `��\��•''�C E MSSj' 1) PUMP OR HEATER MAKE / MODEL MAY NOT BE CHANGED • •. 2) INSTALLATION SHALL COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS: '• No. 20,945 3) EQUIPMENT LOCATIONS MAY NOT BE CHANGED. 4) VARIABLE SPEED PUMP USE MAXIMUM FLOW IN CALCULATION. .•• STATE OF SIGNATURE / DATE CONTRACTOR: CERT. # ALL AMERICAN POOLS INC. CPC 057355 Sheet 3 of 3 SIGNATURE / DATE PAUL WELCH INC. PAUL WELCH P.E. CERT# 29945