Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST, LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 } 1. New construction or existing New (From Plans) 10. Wall Type01442.0 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ent Insul, Exterior R=4.1 1250.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 c N/A 4. Number of Bedrooms 2 R= ft2 d. N/A R= 5. is this a worst case? Yes ft2 11. Ceiling Types (1504.0 sgft.) Insulation Area 6. Conditioned floor area above grade (ft2) 1474 a. Under Attic (Vented) R=30.0 1474.00 ft2 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(141.3 sgfL) Description Area 12. Ducts R ft2 a. U-Factor: S91, U=1.04 101.25 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 125 SHGC: SHGC=0-29 b. U-Factor: Sgi, U=1.11 40.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 C. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.284. a. Electric Heat Pump 34.8 HSPF:8.50 8. Skyfights Area G. U-Factor:(AVG) NIA ft2 SHGC(AVG): N/A 15. Hot water systems 9. Floor Types (1473.5 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473-50 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. NIA R= ft2 16. Credits None Glass/Floor Area: 0.096 Total Proposed Modified Loads: 44.66 PASS Total Baseline Loads: 45,56 hereby certify that the plans and specifications covered by this calculation in Review of the plans and 'SSE ST are compliance with the Florida Energy specifications covered by this O� Code. p calculation indicates compliance�f�'' PREPARED i3Y: with the Florida Energy Code, DATE: Before construction is completed �. this building will be inspected for 04-i compliance with Section 553.908 i hereby certify that this building, as designed, is in compliance * 4 Florida Statutes. with the Florida Energy C--dp- OWNS E�q WE BUILDING OFFICIAL: DATE: i DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3,2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). V13/2021 8:02 AM EnergyGaugeo USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE STERLING IMP Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE _ / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft' ___ 0 1 0 2SIab-On-Grade Edge lnsulatio WIC 1ft 0 63 ft' ____ 0 1 0 3 Slab -On -Grade Edge lnsulatio M. BATH 8 ft 0 56 ft' __ 0 1 0 4SIab-On-Grade Edge lnsulatio KITCHEN 1 ft 0 192 W ___ 0 1 0 5 Slab -On -Grade Edge lnsulatio BATH 5 ft 0 45 fF ___ 0 1 0 6 Slab -On -Grade Edge lnsulatio BEDROOM 2 32.2 ft 0 203.5 ft' __ 0 1 0 7 Slab -On -Grade Edge lnsulatio ENTRY 7 ft 0 55 ft' 0 1 0 1/13/2021 8:02 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 - 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 fF -_ 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft2 246 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft2 N N CEILING # Gelling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63f2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft- 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood 10 Knee Wall (Vented) BEDROOM 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width P Height Sheathing Framing Solar Below o _ 1 NE=>SW Exterior Concrete Block - Int InsuBEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 2 SW=>NE Exterior Concrete Block - Int InsrBEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 3 NW=>SE Exterior Concrete Block - Int lnsuBEDR00M 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 _ 4 SW=>NE Exterior Concrete Block- Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 _ 5 NE=>SW Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _ 6 NE=>SW Exterior Concrete Block- Int InsBIEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 _7 SE=>NW Exterior Concrete Block -Int InsBEDROOM2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 8 S=>N Exterior Concrete Block - Int InSBEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 _ 9 SW=>NE Exterior Concrete Block - Int Ins9EDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block - Int Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 11 SW=>NE Exterior Concrete Block- Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 12 SW=>NE Exterior Concrete Block - Int InsuLAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 13 NE=>SW Exterior Concrete Block - Int lnst$REAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block - Int InstOREAT/DINT 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 1/13/2021 8:02 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 fY 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Ft Width Height In Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6ft- WINDOWS Orientation shown is the entered orientation => chanced to Worst Case. / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 1.04 0.29 N 32.9 ft' 1 ft 0 in 1.04 0.29 N 6.9 ft' 1 It 0 in 1.04 0.29 N 24.0 ft' 6 ft 0 in 1.04 0.29 N 37.5 ft' 1 ft 0 in 1.11 0.27 N 40.0 ft' 8 ft 0 in 1 ft 5 in Drapes/blinds 1 ft 5 in None 1 ft 5 in None 1 ft 5 in None 1 ft 5 in Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315W 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.48 141.7 A263 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER:15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None 1/13/2021 8:02 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R4O5-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply — -- Return-- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 125 ft2 Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[e Ceiling Fans: Ian Feb Heating [ Jan pQ Feb ((]� [X1 Mar Apr € MayX� MN Jun 4 j Jul jJC� [ ]Au[ (Xj ]Sep [ ] L J Oct Dec Venting t I Jan [ 1 Feb Ia7 Mar ay Jun I 1 Jul [ 1 Aug I 1 Sep lxJ Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 7e 78 78 78 78 78 78 78 78 Cooling (WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. O ft2 Oft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(81bs/sq.ft. ft2 It 0.3 M. BATH Default(8 lbs/sq.ft. ft2 It 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 It 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 ENTRY Default(8lbs/sq.ft. ft2 It 0.3 LAUNDRY Default(8 lbs/s .ft. ft2 ft 0.3 GREAT/DINING Ill 3/2021 8:02 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Y Owner: Jurisdiction: w Design Location: FL, Fort Pierce O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-penneable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing Cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking,or floor framing cavity g insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spax as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nonino and wirina Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or airsealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions of ICC1100. 1/13/2021 8:02 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. THE STERLING, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 2 5. Is this a worst case? Yes 6. Conditioned floor area (ft-) 1474 7. Windows" Description Area a. U-Factor. Sgl, U=1.04 101.25 ft= SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 ft- SHGC: SHGC=027 c. U-Factor. N/A ft= SHGC: d. U-Factor. WA ft2 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 8. Skylights Description Area a. U-Factor(AVG): N/A ft2 SHGC(AVG): N/A 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft- b. N/A R= ft2 c. N/A R= ff2 10. Wall Type and Insulation Insulation Area a. Concrete Block - Int Insul, Exterior R=4.1 1250.00 f - b. Frame - Wood, Adjacent R=11.0 192.00 fN c. N/A R= ft2 d. WA R= ft2 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft2 b. Knee Wall (Vented) R=19.0 30.00 ft2 c. N/A R_ ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 125 13. Cooling systems kBtu/hr Efficiency a. Central Unit 34.8 SEER:15.00 14. Heating systems kBtulhr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 15. Hot water systems a. Electric Cap: 50 gallons EF: 0.97 b. Conservation features None Credits (Performance method) None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature:-- Date: Address of New Home: City/FL Zip: -3ti5sa *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/13/2021 8:02 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 wri9htSoftm Project Summary Job: Date: Jan 13, 2021 Entire House By, QUICK CALCS, INC. 317 ST. LUCIE LN.,Fr. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466,796 Emil: QUICKCALCSc�i OL.COM Project Information For. WYNNE DEVELOPMENT THE STERLING, FT. PIERCE, FL Notes: Design Information Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18852 Btuh Structure 17877 Btuh Ducats 5654 Central vent (0 cfim) 0 Btuh Btuh Ducts Central vent (0 cfm) 8536 0 Btuh Bluh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24506 Btuh Use manufacturer's data n Infiltration Rate/swing multiplier Equipmeni load 0.95 sensible 25093 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2958 Btuh Duds 2319 Btuh Central vent (0 cfin) 0 Btuh Heatingg Area(1l2) Coolingg (none) 1474 1474 Equipment latent load 5277 Btuh Volume (to) 12227 12227 Airchanges/hour 0.45 023 Equipment Total Load (Sen+Lat) 30370 Btuh Equiv.AVF (cirn) 92 47 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536R 030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 33 OF 8.5 HSPF 34600 Btuh @ 47-F 27 OF 1160c(m 0.047 crm/Btuh 0.50 in H2O Baciap: Input=7kW, Output= 23009 Btuh, 100 AFUE Make Carver Trade CARRIERAIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Sensiblecooling 24360 Btuh Latentcooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 clam Airflowfactor 0.044 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCAto meetall requirementsof Manual J 8th Ed. Wrlaht aft- 2021-Jarv1308:11:06 1. Ri9ltStAe@Uriversal201919.021 RSU08101 Paget ..nwrengfboftWAC\WY NE-THESTERUNG. p Calc=W8 %AOoorfa� N 1# wrightsoft- RighW@ Worksheet Job: Entire House Date: Jan 13, 2021 QUICK CALCS, INC. By. 317 ST. LUCIE LN.,FT. PIERCE, FL 34W Phore: 772-466-6799 Fa 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room mama EntreHouse MASTER BEDROOM 2 Elpcsedwall 1802 it 52.0 it 3 Room height 8.3 ft of SA it heaHmol 4 Room dimensions 1.0 x 329.0 ft 5 Room area 14735 ft2 329D ft2 Ty Construction U-slue Or HTM Area Load Am number (BMh/F--°F) (BL[w or perimeter (ft) (Btuh) or Pedmer M (BNh) Heat Cool Gross N/PS Heat Cool Grass WPS Heat Cool 6T_G 13AA= 0.143 ne 4.00 2.55 479 442 1768 1124 80 80 320 204 1Aclom 1270 ne 3556 70.43 38 0 1344 2662 0 0 0 0 13A-0ac 0.143 se 4.00 255 128 83 331 210 0 0 0 0 1Aciom 1270 se 3556 34.77 24 24 848 829 0 0 0 O 11 11DO 0.390 se 10.92 11.31 22 22 236 244 0 0 0 0 W 13A4a 0.143 s 4.00 2.55 34 34 136 86 0 0 0 0 13A-4o s 0.143 m 4.00 2.55 360 353 1414 899 224 224 897 570 1Aciom 1270 w 3556 42.91 7 5 247 298 0 0 0 0 13A-0as 0.143 M 4DO 2.55 290 217 867 551 112 79 318 202 1Ac1om 1270 nw 3556 4524 33 0 1162 1478 33 0 1162 1478 4A5-2om 0.770 nw 2156 27.54 41 0 880 1124 0 0 0 0 P 12C-Om 0.091 - 2S5 128 192 192 489 246 0 0 0 0 C 16A30md OD32 - 0.90 2.32 1474 1474 1320 3419 329 329 295 763 F 22A-tol 0989 - 27.69 0.00 1474 180 4989 0 329 52 1440 0 6 c)AED e=rsion 784 680 Envelope losslgain 16030 13954 4432 3897 12 a) Ird ation 2822 773 909 249 b) Roomu llaton 0 0 0 0 13 hbtenalgers: Omlpants@ 230 5 1150 2 460 Applimossiother 2000 0 Subtotal(Iines61oi3) 18852 17877 5341 4606 Less external load 0 0 0 0 LeatanSer 0 0 0 0 Redishibulion 0 0 0 0 14 Subtotal 18852 17877 5341 4606 15 Duo:loads 30% 48% 5654 8536 30% 4896 1602 2199 Total room load 24506 26413 1 6943 6805 Airrequired(din) 1160 1160 329 299 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed -rid- wrightsoTt- 2021-Jarrv1308:11:06 RigltSuts&Uriwml20l9l9.O2l RSU08101 Pagel ...e rislWdghtsoft WAC1WYNNE-THESTERLINGnp Calc=MIB FrortDoorfares: N t l wrighilsoft Right4@ Worksheet Job: Entire House Date: Jan 13, 2021 QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 PIore:772-466-6799 Fax 772-4666796 Email: QUICKC4LC55-40LCOM 1 Room name WIC M BATH 2 Exposaddwall 0 ft 8.0 ft 3 Room height 8.0 ft heaV000l 8.0 ft heec of 4 Room dimensons 7.0 x 9.0 it 7.0 x 8.0 It5 Room area 63.0 1P 56.0 tF Ty Consbumon U-value Or HTM Area (ft) Load Area (Rj Load number (Bfuhd�°FF) (BWhftn or penmetar (ft) (BWh) or perimeter (ft) Eluh) Heat Cool Gross NIPS Heat Cool Gross WPS Heat Cool 6 W 13AAois 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 t—C 1Aaiom 1270 ne 3556 70.43 0 0 0 0 0 0 0 0 13A4= 0.143 se 4A0 255 0 0 0 0 0 0 0 0 1Aclom 1270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 11DO 0" se 10.92 11.31 0 0 0 0 0 0 0 0 W 13A = 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 t13A4ors 0.143 sN 4.00 2,55 0 0 0 0 64 57 228 145 —C 1A-ciom 1270 sw 3556 42.91 0 0 0 0 7 5 247 298 13A4ors 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 tAclom 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 4A5-20m 0.770 nw 2156 2754 0 0 0 0 0 - 0 0 0 P 12C-0Ow w 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C 16A30md 0A32 - 0.90 2.32 63 63 56 146 56 56 50 130 F 22A-tol 0.989 - 27.69 0.00 63 0 0 0 56 8 222 0 6 c)AED exarsim -2 225 Ervelope losslgain 56 145 747 798 12 a) Infiltration 0 0 740 38 b) Roomventilabon 0 0 0 0 13 trrasnal gains: Oaupants@ 230 0 0 0 0 Applianceyother 0 0 Subtotal(lines6to13) 56 145 887 836 Less load 0 0 0 0 Les4zrzer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 145 8137 836 15 Ductloads 301 481 17 69 30% 48% 266 399 Total room load 73 214 1153 1235 Air required(htrn) 3 9 55 54 Calculations approved byACCAto meet all reouirements of Manual J 8th Ed c w oT�' 2021-Jarrv1308:11:06 c� Right-SuteOUriversa1201919.021 RSU08101 Page ...00merts\Wngftofi HVAC1WYNNE-THESTERLINGnp Calc=MIS FrortOoorfaces:N wrightsofr RighW@ Worksheet Job: Entire House Date: Jan 13, 2021 QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Plxm: T12-466-6799 Fax 712466-6796 Email: QUICKCALCS@AOL.COM 1 Room name KITCHEN BATH 2 Exposalxall 8.0 It 5.0 ft 3 Room height 8.0 ft heaVmol 8.0 ft heaV=l 4 Room dimensions 1.0 x 192.0 It 9.0 x 5.0 it 5 Room area 192.0 V 45.0 fF Ty Construction U-value Or HTM Area (fF) Load Area (M Load number (BIuhflF-*9 (BWh%t'0 or perimeter (ft) (BWh) or perimeter (ft) (I3Wh) Heat Caol Gross NIPS Heat Cool Gros WP5 Heat Cool 6 13A4= 0.143 m 4.00 2.55 0 0 0 0 40 40 160 102 1Aatom 1270 ne 3556 70.43 0 0 0 0 0 0 0 0 13A-0as 0.143 se 4.00 2,55 0 0 0 0 0 0 0 0 1A-Oom 1270 se 3556 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 se 1092 11.31 0 0 0 0 0 0 0 0 W 13AA= 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sv 4.00 2.55 0 0 0 0 0 0 0 0 1Aciom 1270 sv 3556 42.91 0 0 0 0 0 0 0 0 13A4= 0.143 rw 4.00 255 0 0 0 0 0 0 0 0 1Aclom 1270 rw 35.56 4524 0 0 0 0 0 0 0 0 4A5-2om 0.770 nw 21.56 27.54 0 0 0 0 0 0 0 0 P 12C-0sv 0.091 - 2.55 128 64 64 163 82 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 192 192 172 445 45 45 40 104 F 22M)l 0.989 - 27.69 0.00 192 8 222 0 45 5 138 0 6 c)AED e=Irson -27 -2 Ernalope toss/gain 557 501 339 204 12 a) Infiltration 0 0 87 24 b) Roomven6lation 0 0 0 0 13 Intemalgains: Omlpant&@ 230 0 0 0 0 Appliancestother 2000 0 Subtotal(lines6to13) 557 2501 426 228 Lesselemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 557 2501 426 228 15 Ductloads 30% 48% 167 1194 30% 48% 128 109 Total room load I I 724 3695 1 554 336 Air required(dm) 34 162 26 15 Calculations approved byACCAto meet all requirements of Manual J 8th Ed - M -;� 1,� 2021-Jan1308:11:06 RigltSute®Uti rs1201919.021RSW8101 Page ...00sreris\Wd9HsoftWACYWYNNE-THE STERLING.rp Calc=WS Fmrt Doorfams:N wrightsoft° RighW@ Worksheet Job: Entire House Date: Jan 13, 2021 QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phorle: 772-466-6799 Fa 772-166.6796 Emil: OUICKCALCSCAAOLCOM 1 Room name 2 BEDROOM2 ENTRY Eposedwall 3 Room height 322 ft 16A It 4 Room dimensons 8.0 4 hea%ol 8.0 ft heatl000l Room area 1.0 x 203Z It 2035 1A x 55.0 It IF 55A IF Ty Conshumon U-value Or HTM Area number (BWh/R'-°Fj (BOrh/F) or perimeter (t) (Btuh) or perimeter (p (Bluh) Heat Cool Gros NWPiS Heat Cool Gros NPIS Heat Cool 6 Vtl �--G 13AAs 0.143 m 4.00 2.55 128 128 513 326 0 0 0 1A-Mm 1270 m 3556 70.43 0 0 0 0 0 0 0 0 13A-0oa 0.743 4.00 2.55 80 56 225 140 48 26 106 0 67 1Ac1om 1270 se 35.56 34.77 24 24 848 829 0 0 0 0 17 11DO 0.390 se 10.92 11.31 0 0 0 0 22 22 236 244 W 13A4= 0.143 s 4.00 2.55 34 34 130 86 0 0 0 13A4c s 0.143 sw 4.00 2.55 16 16 64 41 8 0 1Actorn 1270 w 3556 42.91 0 0 0 0 0 8 32 0 20 13A-4os 0.143 nv+ 4.00 2.55 0 0 0 0 0 0 1Aclom 1270 my 3556 4524 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 2156 2754 0 0 0 0 0 P C 12C-09w 16"Md 0.091 2,55 128 0 0 0 0 72 72 0 0 183 0 92 F 22A-tpl 0.032 0.989 - - 0.90 27.69 2,32 0.00 204 204 204 182 472 55 55 49 128 32 891 0 55 16 443 0 6 c)AEDe ram _2q � Envelope loss/gain 2859 1873 10gg yu 12 a) IMtlhation 564 154 122 34 b) Room centila5on 0 0 0 0 13 Intemalgains O=pantsl230 1 23 0 Appliancesother 0 0 0 Subtotal(lines6to 13) 3422 2257 1172 579 Les e*mal load 0 0 0 0 Lestrander 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3422 2257 1172 579 15 Duo:loads 30% 48% 1026 1078 30% 48% 351 276 Tofal mom load 4449 Airrequired (cfm) 7�4s Calculations approved bvACCAto meet all requirements of Manual J 8th Ed 2021Ja 1308:11:06 .A LA RigTHES(ERUNnnp Cac=W8 RSU08101 ...oamerts\WdgHsoft HVAgWYNNE-THE BTERLINGnp Calc=M78 FroHDoortaces: N Page F� wrightsoft- RighW@ Worksheet Job: Entire House Date: Jan 13, 2021 QUICK CALCS, INC. By. 317 ST. LUCIE UN., Fr. PIERCE, FL 34946 Ptore: 772.466-6799 Fax 712-466-6796 Emil: QUICKCALCS@4OL.COM 1 Roam name LAUNDRY GREAT/DINING 2 E)posd wall 13.0 ft 46.0 ft 3 Room height 8.0 ft heaV000l 8.9 ft heaV000l 4 5 Room dimensions Room area 7.0 x 6.0 ft 1.0 x 488.0 It 42.0 IF 488A ft' Ty ConsWcton U-Ialue Or HTM Area (� Load Area Load number (BWh4F--°F) (BNhAt� or Perimeter (ft) (Bluh) or penmetar (ft) (BWh) Heat Cool Gros NrP/S Heat Cool Gross NFS Heat Cool 6 Vil �C 13AAocs 0.143 ne 4.00 2.55 0 0 0 0 231 194 776 493 1A,1am 13A-4= 1270 0.143 ne as 3556 4.00 70.43 2.55 0 0 0 0 0 0 0 38 0 1344 2662 tAclom 1270 se 35.56 34.77 0 0 0 0 0 0 0 0 0 0 0 0 11 D 11D0 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 0 W 13A-40s 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 t13A4oca 0.143 sN 4.00 2,55 48 48 192 122 0 0 0 0 —G 1Aclom 1270 m 3556 4291 0 0 0 0 0 0 0 0 13A4ors 0.143 nw 4.00 2.55 0 0 0 0 178 137 549 349 1Actarn 1270 nw 3556 4524 0 0 0 0 0 0 0 0 4A5-2om 0.770 nw 21.56 27.54 0 0 0 0 41 0 880 1124 P 12C-Om 0.091 - 255 128 56 56 143 72 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 42 42 38 97 486 488 437 1132 F 22A-tpl 0.989 - 27.69 0.00 42 13 360 0 488 46 1274 0 6 a)AEDe=m.on _3 -56 Envelope loss/gain 733 288 5259 5704 12 a) Infiltration 105 29 8951 24 b) Room ventilaton 0 0 0 0 0 0 13 Internal gains: Oompants@ 230 0 0 2 Appliancestother 0 460 0 Subtotal(llnes6ht13) 837 317 6154 6409 Less elbamal load 0 0 0 0 s Letransrer 0 0 0 0 Redistribution 0 0 0 0 14 Sublotal 837 317 6 6409 15 DUQloads 30% 48% 251 151 30% 480A 1846846 3060 Total room Toad Air required (dm) 1089 468 87 9469 52 21 379 416 Calculations approved byACCAto meet all requirements of Manual J 8th Ed wrigh>�o1'[� 2021-Jan1308:11:06 RigTHES ERLI G.nprsal s1c= 21 RSW8101 ...owrer6lWnghSoR HJACIWYNNE-THE STERLING.np Calc=M78 FrortDoorfa¢s: N Page - wrightsoft° Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE UN., Fr.. PIERCE, FL 34946 Plum 772-466-6799 Fax 772466-6796 Emil: OUICKCALCS@AOL.COM Project For. WYNNE DEVELOPMENT THE STERLING, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest fiction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250/0250 in H2O 0.284 in/100ft 1160 cfrn 176 Supply Branch Detail Table Job: Date: Jan 13, 2021 By. Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0250 in H2O 0.284 in/100ft 1160 cfm Name Design (Btuh) Htg (dim) Clg (cm) Design FR Diam (in) H x W (in) Dud Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 554 26 15 0.376 4.0 Ox0 VIFx 18.1 115.0 st1 BEDROOM h 4449 211 146 0.374 6.0 OxO MFx 18.6 115.0 st1 ENTRY h 1523 72 38 0.510 5.0 OxO VIFx 3.0 95.0 GREAT/DINING c 4735 189 208 0.318 7.0 Ox0 VIFx 22.4 135.0 st2 GREAT/DINING-B c 4735 189 208 0.307 7.0 Ox0 VIFx 28.1 135.0 st2 KITCHEN c 3695 34 162 0.375 7.0 Ox0 VIFx 18.3 115.0 st1 LAUNDRY h 1089 52 21 0.366 6.0 Ox0 MFx 21.6 115.0 st1 M. BATH h 1153 55 54 0.366 4.0 Ox 0 VIFx 21.6 115.0 st1 MASTERBEDR00%A h 3471 164 149 0.297 6.0 Ox0 VIFx 33.1 135.0 st2 MASTERBEDROOM-B h 3471 164 149 0.284 6.0 OxO VIFx 41.1 135.0 st2 WIC c 214 3 9 0.310 4.0 Ox0 VIFx 26.3 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Ciro) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 711 724 0.284 922 12.0 0 x 0 VInIFIx st1 st1 PeakAVF 1088 1122 0.284 1050 14.0 0 x 0 VinlFlx a 10 Wriightso 2021-Ja 1306:11:06 Rigtt-Sute®Unversa1201919.021 RSU08101 AM Pagel ...ac rbi Wngttmt FNACIWYNNE-THESTERLING.np Calc=M18 FrortDoorfaas: N Return Branch Detail Table Name Grille Size(in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/joist Opening(in) Duct Matl I Trunk rb1 Ox0 1160 1160 0 1 0 0 0 Ox 0 1 VIFx t Wrlghtsoft® 2021-Jarv1308:1196 •.�• ...,—..�.,.-, liigttSufe®UriwTW1201919.021 RSU08101 Page 2 ...oamerls\WnghSoft HVAC1WYNNE-iHE STERLING.np CaIc=NJB Frort DoorfarBSN