HomeMy WebLinkAboutEngineersM TYPICAL PLAN 1" = 1'-0" 8 L DECKING FASTENED TO STRINGERS AS SPECIFIED, MODIFICATION TO COMPOSITE DECKING ALLOWED ATTACH PER MANUFACTURER SPECIFICATIONS K J I G F I TYPICAL SECTION 8 Ei ELEV 0.0 ATTACH DECKING WITH #10 X 3" (304 SS) SCREWS, 2 PER DECK STRINGER STRINGER — BENT OR CROSS BUCK SEE SITE PLAN FOR LENGTH AND LOCATION FLITCH EXTERIOR STRINGER FOR FUSH APPEARANCE ALL THRU BOLTS, NUTS, WASHERS 8" STAINLESS W NUT FULLY THREADED PG3OF5 DOCK SECTION MHW PROFILE ELEV 1.0 OWNER Sawyer Residence 606 Willows Way Port St Lucie, FL 34952 ALL PILINGS 8" PERMITTING Treasure Coast Barge Permit Department 1200 SE Dixie Cutoff Rd Stuart, FL 34994 v D NEW SEAWALL ENGINEER PILINGS JETTED TO A MINIMUM 6' PENETRATION AS REVIEWED FOR MCR ENGINEERS NEEDED FOR ADEQUATE BEARING AND STABILITY -ODE COMPLIANCE MARINE - CIVIL & RESTORATION C SEE SPECIFICATIONS SHEET 4 FOR FASTENER ST. LUCIE COUNTY JENSEN BEACH, AND COMPONENT SIZE AND SPECIFICATION FL 34957 CENTER STRINGERS TOE NAILED F30CC 772-214-4800 W (2) # 16 (304 SS) STRINGER BUTT SPLICE DETAIL B RING SHANK NAILS @ EACH 8' = 1'-0" � E N� BENT. '0/ ` 18" �� NO.A3855 �` s OUTSIDE STRINGERS FACE 18 r yn NAILED W 16 RING SHANK (304 ,•, , j35�Zp r A SS) AS SHOWN `_ STATE OF k , •,53 NAL �G•,, 1 2 3 4 5 :l. 63��:L ? °• M Design Criteria 2020 Florida Building Code 7TH ED Exposure Classification - D Wind Load Basis -ASCE 7, 2010 Edition Building Classification - 2 Basic Wind Speed - 160 MPH Open Structure L IN J a G F E LC C B A Mean Height - 5' Material Specifications 1) The following are minimum specifications, increased pile size, etc., is approved. 2) Substructure a) Pilings -8" , Marine, 2.5 CCA (See plan view) b) Cross Ties - 2" x 8", #2 Grade, SYP .40 ACQ (All bents doubled). Stringers - 2" x 8", #2 Grade, SYP .40 ACQ 3) Decking 2X6 PT # 1 PT Bull Nose decking 4) Fasteners a) Thru Bolts, All thread -5' 304 Stainless with stainless lock washers and nuts b) Interior stringers toe nailed to bents c) Deck Fasteners - 3" # 10 Stainless, Self Drilling, 2 per deck board / stringer Installation Specifications The purpose of these specifications is to define uniform construction standards in terms of both geometry (length, width, and height) and construction practice (materials used and how they are installed). 1)SUBSTRUCTURE a) Cross Ties - Extended 3" beyond pile centerline, not to project beyond exposed edge of pile. b) Stringers - 24" max cl to cl if 2x6, 16" cl to cl if composite. Overlapped as needed to ensure end of stringer projects past underlying cross tie minimum 2", not to extend to the extent that stringers or deck boards can impede boats. Exterior edge of piling shall be a minimum of 2 " outside of any cross tie, stringer, or deck board. Exterior stringer to be doubled with flitched joint between pilings and bolted to piling for flush appearance. , it, iEWE® FOR ODE cOMPLIANCE 1 I 2 3 4 5_ 6 900C 1 8 PG40F5 SPECIFICATION OWNER Sawyer Residence 606 Willows Way Port St Lucie, FL 34952 PERMITTING Treasure Coast Barge Permit Department 1200 SE Dixie Cutoff Rd Stuart, FL 34994 ENGINEER MCR ENGINEERS MARINE - CIVIL & RESTORATION JENSEN BEACH, FL 34957 772-214-4800 0 E N q-/ NO.438 5 r• j +t v' 135ep ?p2' / STATE OF W W