Loading...
HomeMy WebLinkAboutLETTER OF APPROVAL M.A. CORSON & ASSOCIATES, Inc. ARCHITECTURE * STRUCTURAL DESIGN 412 Colorado Ave., Stuart, Fl. 34994 (772) 223-8227 * Lic. #AR91665 To: St. Lucie County - Building & Code Regulation Division Date: October 16, 2020 Re: Edward Schmidt 9940 S. Ocean Drive Unit 902 (Middle) Jensen Beach, Fl. , 34957 It is acceptable to replace the existing sliding glass door openings for the address listed above as follows: 1) S.G.D. - The PGT "770" series aluminum S.G.D. has a Florida number NOA #19-1126.03 with a +90 / -90 design pressure. It has a small and large missile "D" approval HVHZ. This unit is located in a Zone 4. SCOPE OF WORK: New sliding glass door. DESIGN PARAMETERS AND ASSUMPTIONS USED: 1. DESIGN CODE: Florida Building Code Sixth Edition (2017) with 2020 Supplements using ASCE 7‐10 2. Structure Designed: Enclosed 3. Risk Category: II Exposure Category: D 4. Design Wind Velocity 170 mph End Zone Width: 4 ft 5. Mean Roof Height 80 ft Roof Pitch: 0:12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: Zone 4: +57.3 / -62.3 P.S.F. & Zone 5: +57.3 / -62.3 . Worst case scenario has been calculated. 7. Design Loads: Floor: N/A Roof/Dead: N/A Roof/Live: N/A Balcony: N/A Dock: N/A Deck: N/A Stairs: N/A Fence: N/A Railings: N/A 8. Were Shear Walls Considered For Structure? N/A Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? N/A 10. Design Soil Bearing Pressure: N/A Soil Test Reports Submitted? N/A Thank you for your time and consideration. If you have any questions please call. Respectfully, Mark A Corson Mark A. Corson A.I.A., NCARB President