HomeMy WebLinkAboutPRODUCT APPROVAL - SWINGING EXTERIOR DOORt u,rarr '
fYl 1 C�
® Professional- , , ,-
Bcrs Home I Log In User Registration HotToplcs. Submit Surcharge I Stats & Facts Publications I Contact Us j BCIS Site Map I Links I Search
Florida .
.. prac Product Approval
1 USER: Public Usv .. .
Product uR Approval Menu > Product or Wlication Search> ppiiiag on List > Application Detall
FL #'. FL17996-R2
Application Type Revision
Code Version 2020
Application Status Approved .
*Approved by DBPR: Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Elixir Door and Metal Company
Address/Phone/Email 1215 Pope -Drive - .
Douglas,: GA 31533
(912).493-2215 .
ryarberry@elixirdmc.com
Authorized Signature. Randall Yarberry ..
ryarberry@eliXi rdmc;con
Technical Representative FTC Product Design Group
Address/Phone/Email PO Box 5.20775
Longwood, FL 32752
(321) 690-1788
info@ptc-corp
Quality Assurance Representative.
Address/Phorie/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method. Certification Mark or Listing
Certification Agency- American Architectural Manufacturers Association
Valldated By American Architectural Manufacturers Association
Referenced Standard and Year (of Standard) Standard- Year
ASTM E330 2002
ASfM E330 2014
Equivalence of Product Standards
CertiFled By Florida Licensed Professional Engineer or Architect
FL17996 R2 Eauly EER 2244 Rev3 ss:Ddf
Product Approval Method Method 1 Option A
Date Submitted 02/19/2021
Date Validated
Date Pending FBC Approval
Date Approved
Surimmary of ProAueta
62/22/2021
02/28/2021
FL #
Model, Number or Name
Description
17996.1
Series,202-20SSteel Door
Series•202-20S Steel O.S. Doorw/Vertical Slider Window
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL17996 R2 C CAC 19359 Elixir - 202-20S OS Door (jbJ,
Approved for use outside HVHZ: Yes
ASTM Jan. 202Ligdf
.Impact Resistant: No
Design Pressure:.+38.7/-32
Quality Assurance Contract Expiration, Date
07/11/2024
Other:
Installation Instructions.
FL17906 R2 II •ELIX0034 Rev B Model-202-205 ss.odf
Verified By: Robert J. Amoruso, PE FL PE No. 49752
Created by Independent Third Party: Yes
Evaluation Reports
FL17996 R2 AE PER 1642 Rev4
ss.odf
Created by Independent Third Party: Yes
17996.2.
Series 230 W9 Steel Door
Series 230 W9. Steel O.S. Door w/ Cottage Window
Limits of Use ...
CertiRcation.Agency Certificate .
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes -
Impact Resistant: No
FL17996 R2 C CAC 19346 Elixir - 230-W9 OS Door 11bi,
ASTM ]on. 2021.o�P -
Quality Assurance Contract Expiration Date
-Design Pressure: +25.3/-25.3
07/11/2024
Other:
Installation Instructions
FL17996 R2 II ELIX0033 Rev B Model 230 W9 .ss.odf
Verified By: RobertJ. Amoruso, PE FL PE No. 49752
Created by Independent Third Party: Yes
Evaluation Reports
FL17996 R2-AE PER, 1642,Rev4 ss.hdf
Created by Independent Third Party: Yes
17996.3 .
Series 402-14
Vinyl Steel Out -Swinging Regular Door -14" x 14" Window
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
Approved for use outside•HVHZ: Yes
FL17996 R2 C CAC 19349 Elixir - 402-14 OS Door ej j,
ASTM )an,2021.odf "
Impact Resistant: No.
Quality Assurance Contract Expiration Date.
Design Pressure:-+66/-56
08/26/2025.
.Other:
Installation Instructions
FL17996 R2 Is ELIX0650 REV-B:OS MODEL 402-14 ss.pdf
Verified By: Robert J. Amoruso, PE FL.PE No: 49752
Created by Independent Third Party: Yes,
Evaluation Reports
FL17996.R2 AE PER 1951 Rev3 ss.g_df
Created by Independent Third Party: Yes
17996.4
Series 402-20S
Vinyl Steel Out -swinging Regular Door - 20" slider window
Limits of Use
Certification Agency Certificate
Approved for use In HVHZ: No
FL17996 'R2 C 'CAC 19358 Elixir - 402-20S.05 Door (],W,
Approved for use outside HVHZ: Yes
ASTM tan. 2021.odf
Impact Resistant: No
Quality Assurance Contract Expiration Date
Design Pressure: +66/-56
08/26/2025.
Other:
Installation Instructions
FL17996 R2 II ELIX0051 REV-B OS MODEL 402 20S ss odf
Verified. By: Robert J. Amoruso, PE FL PE No. 49752
Created by Independent Third Party: Yes .
Evaluation Reports-
FL17996 R2 AE PER 1951 Rev3 ss.od(
ride endent Third Party: Yes
17996.5
Series 407
Vinyl Steel Out -Swing Regular Door - Blank (no window)
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL17996 R2 C CAC 19345 Elixir - 407 OS Door (1b) ASTM
Approved for use outside HVHZ: Yes
Jam 2021.2 ff
Impact Resistant: No
Quality. Assurance Contract Expiration Date
Design Pressure: +56/-50
08/19/2025
Other:
Installation Instructions
FL17996 R2 II ELIX0052 REV-B OS MODEL 407 ss.r�df
Verified By: Robert J. Amoruso, PE FL PE No. 49752
Created by Independent Third Party: Yes
Evaluation Reports
FL17996 RZ AE PER 1951 Rev3ss.pdf
Created by Independent Third Party: Yes
17996.6 Series 430 WJ
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ:'Y4ds
impfict Resistant: No
Design Pressure: +56/-SO
Other:
Vinyl Steel Out -swinging Regular Door.- 9-Lite Window (1'8" x
Yd")
Certification Agency Certificate
FL17996' R2 C CAC 19344 Elixir - 430=W9 OS Do& (1b)
0 .
Quality Assurance Contract Expiration Date
08/25/2025
Installation Instructions
FL17996 R2 II ELIX0053 REV-B OS MODEL 430-W9 ss od
Verified By: Robert J. Amoruso, PE FL PE No. 49752
Created by Independent Third Party: Yes
Evaluation:Reports•
FL17996 R2 AE PER 1951 Rev3 gWAF.
Created by Independent Third Party: Yes
17996.7
Series 6400 W9 Cottage
Series 6400-W9 Non -Impact Inswing Painted Steel Door
w/Storm Door '
Limits of Use
Approved for use in HVHZ:. No
Certification Agency Certificate
FL17996 R2 •C CAC 19352 Elixir - 6400-1N9 IS Door'w-Srnrm
'Approved for use outside HVHZ:.Yes
Impact Resistant: No
Design Pressure: +66.7/-56.7
(1b) ASTM Jan. 2021.u�
Quality Assurance Contract Expiration Date
09/07/2024
Other:
-Installation Instructions
FL17996 112- II .ELIX0056 Rev-8 IS MODEL 6400-W9 WM
STORM DOOR ss.pdf-
Verified By: Robert J. Amoruso, PE FL PE No. 49752 .
Created by IndependentThird.Party.: Yes
Evaluation Reports
FL17996 R2-AE PER'.1954 Rev3 ss.o-
Created by Independent Third Party: Yes..
17996.8
Series 7500 Oval
Series 7500:Non-Impact Inswing Vinyl Laminated Steel Door
w/Storm Door and PVC Jambs
Limits of.Use
Approved for use in HVHZ: No
'Approved for use outside HVHZ* Yes
Impact Resistant: No
Design Pressure: +50/-50
Other:.
Certification Agency Certificate .
FL1706 R2 C CAC 19348 Elixir - 7500 IS Door w-Storm
f 1,_ASTM Jan. 2021.odf
Quality Assurance Contract Expiration Date
08/23/2024
Installation Instructions.
FL17996 R2 II ELIX0060 Rev-B-IS MODEL STR 7500 OVAL
WITH
-STORM DOOR ss.odf-
Verified By: Robert J. Amoruso, PE FL PE No. 49752
Created by Independent Third Party: Yes
Evaluation Reports
FL17996 R2 AE PER 1955 Rev3
ss.odf
Created by Independent Third Party: Yes
--]
17996.9
Series 8406 W9.Cottage
Series 8400-W9 Non -Impact Oval Inswing Vinyl Laminated
Steel Door w/Storm Door
Limits of Use..
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Certification Agency Certificate
FL17996 R2 C CAC 19353 Elixir - 8400-W9 IS Door w-Storm
( lb) ASTM ]an. 2021.pdf
-Impact Resistani: No
Design Pressure: +50/-50
Other:
Quality Assurance Contract Expiration Date
.09/07/2024
Installation Instructions
FL17996' R2 II ELIX0057 Rev-5 IS MODEL 8400 W9' OVAL
WITH STORM DOOR ss.odf
Verified By: Robert J: Amoruso, RE FL PE No. 49752
Created by Independent Third Party: Yes
Evaluation Reports
FL17996 R2 AE PER 1954 Rev3 ssmpdf
Created by Independent Third Party: Yes
17996.10
Series 9000.
Series 9000 Non -Impact Inswing Vinyl Laminated Steel Door
w/Storm Door
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure:.+50/-50.7
Other:
Certification Agency Certificate
FL17996 112 C CAC 19374 Elixir.- 9000 IS Door w-Storm
lb-ASTM ]an. 2021.pdf '
Quality -Assurance Contract Expiration bate
.09/06/2024
Installation Instructions
FL17996 R2 II ELrX0058 Rev-BiS BLANK 9006 DOOR W.
STORM DOOR ss.odf
Verifed By: ,Robert J. Amoruso, PE FL PE No. 49752
Created by Independent Third Party: Yes
Evaluation Reports
FL17996 R2 AE PER 1954 Rev3 ss odf.
Created by Independent Third Party: Yes
17996.11
Series 9400-W9 Cottage
Series 9400-W9 No Inswing Vinyl Laminated Steel
Door w/Storm Door
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Certification Agency Certificate
FL17996 R2 C CAC 19350 Elixir - 9400=W9 IS Done w-Storm
(1b) ASTM Jan: 2021:0d�
Quality. Assurance Contract Expiration Date
09/06/2024
Other:
Installation Instructions
FL17996 R2 II EUX0059 Rev-B IS MODEL 9400-W9
COTTAGE W: STORM DOOR ss,odf
Verified By: Robert J. Amoruso, PE FL PE No. 49752
Created by IndependentTh.ird Party: Yes
Evaluation Reports
FL17996 R2 AE PER 1954 Rev3 ss.pdf
Created by Independent Third Party: Yes
17996.12
Series AFIF7N
Series AFIF7N Non -Impact IS Fiberglass"Doar
Limits of Use
Approved for use in No
Approved for use outside HVHZ: Yes
Certification Agency Certificate
FL17996 R2 C CAC 19351 Elixir - AFIF7N IS Door ib) ASTM
]an. 2021,odf
Impact Resistant: No
Design Pressure: +38J/-38.7'
Quality Assurance Contract Expiratiod Date
08/21/2024
Other:,
Installation. Instructions.
FL17996 R2 H ELIX0040 AFIM-BFIFM RevB ss.pdf
Verified By: Aobert J,. Amoruso, PE FL PE No. 49752
Created by Independent Third Party: Yes
Evaluation Reports
FL17996 R2• AE. PER' 1952 Rev3 ss,pdf
Created by Independent Third Party: Yes
17996.13
Series-AVIM
Series AVIF7N, Non -Impact IS Steel Door
Limits of Use
Approved for use in HVHZ: No
Certification Agency Certificate
FL17996 R2 C CAC 19356 Elixir - AVIF7N IS Door (ih�• ASTM
]an,.2021.od
Quality Assurance Contract Expiration Date.
07/22/2025
Approved for use outside HVHZ.-Yes
Impact Resistant: No
Design Pressure: +38/-38
'Other:
,Installation Instructions
FL17996' R2 •II. ELD(0047 AVIF7N RevB ss,gdf
'Verified By:.Robert J:'Amoruso, PE FL PE No: 49752
Created by Independent Third Party: Yes
Evaluation Reports
FL17996'112.AE PER 1953 Rev3 ss.odf .
Created by Independent Third Party: Yes
17996.14
Series BFIF7N
Series BFIF7N Non-ImpactIS Fiberglass Door
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No .
Approved for use outside HVHZ: Yes
FL17996 R2 C 'CAC 19357 Elixir - BFIF7N. IS Door.w-Side
Lites 1b ASTM Jan. 2021,Ddf
Impact Resistant: No ..
Design Pressure: +38.7/-38.7
Quality Assurance Contract Expiration Date
'08/21/2024
Other:
Installation Instructions
FL17996 R2 3I ELTX0040 AFIF7N-BFIF7N RevB ss.odf
Verified By: Robert J. Amoruso, PE FL PE No. 49752
Created by Independent Third Party: Yes
.Evaluation Reports
FL17996 R2 AE PER 1952 Rev3 ss.odf
Created by Independent Third Party: Yes
17996AS
Series BVI63S
Series BVI63S Non -Impact Single Inswing Door w/Fixed Lite
Insert and Outswing Storm Door
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Certification Agency Certificate
FL17996 R2 C CAC EXR BVI63S E331)-olus5,odf
Quality Assurance Contract Expiration Date
12/17/2021
Design Pressure: +65/-65
Installation Instructions
Other:
FL17996- R2 II ELIX6061 BVI63S RevB ss.pdf
Verified By: Robert J. Amoruso, PE FL PE No. 49752
Created by Independent Third Party: Yes
Evaluation Reports
FL17996 R2 AE PER .2244"ReV3 ss:Ddf .
Created by Independent Third Party: Yes
17996.16
Series BVIF7N
Series BVIF7N Non -Impact IS Steel Door
Limits of Use
Approved for -use in HVHZ: No
Approved for use outside HVHZ: Yes
Certification Agency Certificate
FL17996 R2 C CAC 19354 Elixir- BVIF7N IS Door (11) ASTM
)an. 2021.odf.
•Impact Resistant: No
Design Pressure: +40/-40
Quality Assurance Contract Expiration Date
07/29/2025
Other:
Installation Instructions
FLi7996 R2 II. ELIX0049 BVIF* BVIF7S RevB ss.pdf
Verified By: Robert J. Amoruso, PE FL PE No. 49752
Created by IndependentThird'Party: Yes:
Evaluation.Reports
FL17996 R2 AE PER 1953 Rev3 ss.Ddf.
v Created by Independent Third Party: Yes'
17996.17 Series BVIF7S : Series BVIF75Non-Irnpact1S Steel Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL37996 '112 C CAC 19355 Elixir - BVIF7S IS Door tv-Storm
Approved for use outside HVHZ: Yes (1b) ASTM Jan. 2021.Ddf
Impact Resistant: No Quality Assurance:Contract Expiration Date
Design .Pressure: +50/-50 07/29/2025
Other: installation Instructions .
FL17996" R2. II ELIX0049 BVIF7N BVIF7S RevB ss,pdf
Verified By: Robert J. Amoruso, PE FL PE Na. 49752.
Created by Independent Third Party: Yes
Evaluation Reports
FL17996 .R2 AE PER 1953 Rev3 ss.Ddf
Created by Independent Third Party:. Yes
ContactUs :: 2601 Blair Stone Road: Tallahassee FL 32399 Phone:850-4B7-1024
The State of Florida Is an AA/EEO.employer. Copyright 2007-2013 State of Florida.:: Prlvacv' Statement :: AccessiblPIM Statement :: Refund Statement
Under Florida law; email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to.thls entity: Instead, contact the office by phone oi• by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1),
Florlda Statutes, effective October 1, 2012, licensees licensed "under Chapter, 455, F.S. must provide the Department with an email address if they have one. The emails -
. provided may be used foroffldal communication with the licensee. However email addresses are public record. If you do not.wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick h=.
.. Product Approval Accepts:
o'er a�
Credit Card
Safe
ELIXIR DOOR & METALS CO.
MODEL-407 NON -IMPACT OUTSWING
VINYL LAMINATED -STEEL: DOOR
INSTALLATION ANCHORAGE DRAWING.
GENERALNOTES:"
1. THE PRODUCT ANCHORAGE SHOWN HEREIN IS DESIGNED
- S.IN AREAS WHERE WINDBORNE DEBRIS PROTECTION
TO COMPLY WITH THE CURRENT EDITION OF THE
REQUIREMENTS EXIST, USE OFAN IMPACT PROTECTIVE
FLORIDA BUILDING CODE (FSC) EXCLUDING HIGH
SYSTEM COMPLYING WITH THE FBC REQUIREMENTS FOR
VELOCITY HURRICANE ZONE AND THE DESIGN
WINDBORNE DEBRIS REGIONS IS MANDATORY FOR THE
PRESSURE(S) STATED HEREIN. -
PRODUCTHEREIN.
1a THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED.
6. FRAME MATERIAL' ALUMINUM ALLOY6063.76 "
UPON SIGNED AND SEALED TEST REPORT
DOOR PANEL MATERIN-:.09 M6- VINYL LAMINATED,
CONSTRUCTION CONSULTING LABORATORY REPORT N
GALVANIZED STEELAIS' SKIN WT URETHANE FOAM CORE.
CCL-19-167 AND ASSOCIATED LABORATORY STAMPED
'
DRAWINGS. .. ..
7. GLASS MEETS THE REQUIREMENTS OF ASTM E1300.12AE1.
1b. TESTED TO ASTM E330-14.
B. DESIGNATIONS'X' STAND FOR THE FOLLOWING;
2. ADEQUACY OF THE EXISTING STRUCTURAL 2X FRAMING
X: OPERABLE PANEL
OR STEEL FRAMING AS A MAIN WIND FORCE RESISTING
O: FIXED PANEL
SYSTEM CAPABLE OF WITHSTANDING AND
TRANSFERRING APPLIED PRODUCTLOADS TO THE
9. HARDWARE. "
FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER
A HALF HINGES. (4) 6063-TS EXTRUDED ALUMINUM
OR ARCHITECT OF RECORD.
B. LATCH LOCK: KEYED
-
C. DEAD BOLT: SINGLE CYLINDER
,.3. WAND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND
ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE
10. SEE SHEET? FOR DESIGN PRESSURE CHART
STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE -
-
. RESPONSIBILITY OF THE ENGINEER OR ARCNITECT OF
11; IF WATER INFILTRATION REQUIREMENT EXISTS, UNIT MUST.
RECORD..
BE INSTALLED BENEATH AN OVERHANG MEETING THE.
CURRENT EDITION OF THE FLORIDA BUILDING CODE -
4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE
BUILDING AND RESIDENTIAL VOLUMES.
GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS
-'
FOR A SPECIFIC SITE IF SITE CONDITIONS CAUSE.
INSTALLATION TO DEVIATE FROM THE REQUIREMENTS -
DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT'
-
SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE
WITH THIS DOCUMENT.
-
'DESIGN PRESSURE RATING (PSF)
IMPACT RATING
WHERE WATER INFILTRATION
REQUIREMENT IS NEEDED
WHERE WATERINFILTRATON
REQUIREMENT IS NOT NEEDED
NONE
-
SEE GENERAL NOTE 11
+501-5.0-
TABLE OF CONTENT
SHEET
DESCRIPTION
1
GENERAL AND- INSTALLATION NOTES
2
ELEVATION, ANCHORING LAYOUT
3
VERTICAL CROSS SECTIONS
4
HORIZONTAL • CROSS SECTIONS
INSTALLATION NOTES:
1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH S. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE
ANCHOR LOCATION:
WALL FINISHES. INCLUDING BUT NOT LIMITED, TO
-
STUCCO, FOAM, BRICK VENEER AND SIDING.
2. THE INSTALLATION ANCHORS ATTHE SPACINGS SHOWN
. ARE THE MINIMUM NUMBER OF ANCHORS AND MAXIMUM
6. INSTALLATION ANCHORS SHALL BE INSTALLED IN
SPACINGS TO BE USED FOR PRODUCT INSTALLATION.
ACCORDANCE WITH ANCHOR MANUFACTURERS"
INSTALLATION INSTRUCTIONS AND ANCHORS SHALL
3.SHIMASREQUIRED ATEACH INSTALLATION ANCHOR.
NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS'
WITH LOAD B EARI NG SHIMCS).'MAXIMUM ALLOWABLE
THAN THE MINIMUM STRENGTH SPECIFIE13INTHE
SHIM SIZE OF 114INCH. SHIM WHERE SPACE OF 1116INCH
'ANCHOR SCHEOULE' THIS SHEET.
OR GREATER OCCURS. SHIM(S)SHALL BECONSTRUCTED.
OF HIGH DENSITY PLASTIC OR BETTER.
7-.INSTALLATION ANCHORS AND ASSOCIATED HARDWARE'
MUST BE MADE OF CORROSION RESISTANT MATERIAL
4: ANCHORS FOR INSTALLATION INTO WOOD FRAMING OR
" OR RAVE A CORROSION RESISTANTCOATING.
. 14GA. MINIMUM STEEL FRAMING SHALL SEAS SHOWN IN
"
'ANCHOR SCHEDULE'THIS SHEET.
ANCHOR SCHEDULE
DOORFRAME
MANUFACTURER
,EMBEDMENT
EDGE
'ANCHOR CAPACITIES
SUBSTRATE
TYPE
TYPE
SIZE
ANDIOR
pN)1�1
DISTANCE
BASEDON
SPECIFICATION
_-
(IN)111a
SHEET '
MIN..3
'
METALUSTEEL
ASME 818.5.4 -
THREADS ,
MIN, 33 KSI YIELD
TUBING 14 GA
FIN (Z-BAR)
PAN HEAD
NO: 8
PAST INSIDE
318,
MIN
(TAPPING SCREW)
SURFACE OF
STRNEGTH
THICKNESS
-SUBSTRATE
.
ANSI818.6.1.
2X WOOD
(WOOD SCREW)
WOOD WITH AMINIMUM
FRAMING
FIN (Z-BAR)
PAN HEAD
NO.8 .
OR
1'
1/2' -
SPECIFIC GRAVITYOF-
.
-ASME B18.6A-,
0.42.
(TAPPING SCREW)
NOTES:
1)-FDR WOOD OR TAPRNG SCREWS IF SPLITING IS A CONCERN, DRILL 0.082E PILOT HOLE (DRILL SIZE45),
2)EDGE DISTANCEMEASUi® FROM BTiERSIDE OFANCHOR TO EDGE OFSUBSTRATE
T
W
O
0
Robert J. Amoluso, P.E.
FL P.E. No.49752
W`>fVi
�WUH.� O,ur
Digitally signed by
RobertJ Amoruso
Date: 2021.02.18
12:08:03-05'00'
38 1• MAX. OA
FRAME WIDTH
36 MAX. : v. .
DOOR PANEL S o
WIDTH W MAX..
O.C. (1YP.) . .
B D . 4• MAX. (1 YP) {.— 4' MAX. (TYP
). m
H O N v
4 .4 3. )� �y N X•u.
F F (�]. c� N EdN 4 4.
G' X: G LOCK ASSEMBLY IS LOCATED APPROX., - : - G'MAX - -C4 • o s c ,
821J4" 60� ' 37•ABOVE BOTTOM OF DOOR LEAF H g }
0.0 (TYP.) 4 4
MAX OA MAX, E O AND THE DEADBOLTASSEMBLY, p
FRAME DOOR 4 4 APPROX. 41' ABOVE BOTTOM OF DOOR X
HEIGHT PANEL LEAF. SEE STRIKE DETAILS THIS O" C E~ Z m
HEIGHT .. SHEET. W o �LL
c
a1° a v zQ
_
rZ',, Zzz. Et 37' m.
FOUR HALF HINGES. 3' + A O s as
AND 21' FROM EACH SILLANCHOR SPACING i16
A C . END OF THE DOOR : SAME AS HEAD•SPACING �4
PANELSECURED
3 .3 BYNBX3/4•SCREINS ANCHOR LAYOUT W yell
ELEVATION QYPJ .. .. EXTERIOR VMW .. .
EX'IBRIOR VIEW .. -
ANCHORING NOTES:
'1. MINIMUM NUMBER OF AN IN JAMBS IS 14.
ANCHOR SPACING.VARIES, BUT NOT TO EXCEED 6'
MAXIMUM O.C. .
118x318`WOOD.. I I' SCREW MUSTTAPPING I
I I . - .. RobeR J. Amoroso, P.E.-
SCREW. 2.. MINIMUM NUMBER OF IN SILL
SCREW SUFFICIENT LENGTH TO IS 6. ANCHOR SPACING VARIES, BUT NOT TO FL P.E No.A9752 .
i I PENETRATE (3) THREADS. EXCEED 6• MAXIMUM O.C. .
I L I MINIMUM BEYOND STEEL - Digitally-.
TUBE.
signed by
Robert)
ENTRY DOOR ENTRY.DOOR
STRIKE DETAIL.. STRIKE DETAII. _ e 1 Dmon�so
WOOoeRAM ESUB mre sres.•nnwasua iuT-z 'q "i ate:
2021.02.18
12:08:47
. -05,00,
T MIN. EMBEDMENT—[—
MBEDMENT #8 WOOD SCREW
INSTALLATION ANCHOR
2X WOOD FRAME
(BY OTHERS)'
1f2' MIN.
SEALANT TAPE TO BACK. EDGE DIST.
SIDE OF MOUNTING FIN
1/4' MAX SHIM
EXTERIOR INTERIOR
1 VERTICAL SECTION
WOOD FRAME SUBSTRATE
EXTERIOR
INTERIOR
�1/4" MAX SHIM
SEALANT TAPE TO BACK
SIDE OF MOUNTING FIN��
1/2' MIN.
EDGE DIST.
2X WOOD FRAME
(BY OTHERS)
1' MIN. EMBEOMENT--
08 WOOD SCREW
INSTALLATION ANCHOR
SECTION
0VERTICAL
WOOD FRAME SUBSTRATE
THREE (3).THREAD
MIN.PENETRATION. #8 TAPPING SCREW
INSTALLATION ANCHOR
SEALANT TAPE TO BACK 3/8' MIN.
SIDE OF MOUNTING FIN • EDGEDIST.
14 GA MIN. SQUARE
STEEL TUBING (BY
OTHERS)
EXTERIOR INTERIOR
(D-%RCAL SECTION
EL TUBINO SUBSTRATE
,EXTERIOR INTERIOR
. /14 GA. MIN, SQUARE
STEEL TUBING (BY
OTHERS)
3/8' MIN.
SEALANT TAPE TO BACK EDGE DIST.
SIDE OF MOUNTING FIN
#8 TAPPING SCREW
... -THREE(3)THREAD INSTALLATION ANCHOR
MIN. PENETRATION
C VERTICAL SECTION
sTEELIMINGSUBSTRATE
,
C
a'.
g
O
N_
N
U
of
c
t,.
o
W
M
Z.
¢
Ems+
Soo
a
is
o,;
U<Vwid
co
d
_�
w
I
S
C 0
a,
zi-'t¢
ZZ�
111
O N-,
OU
R
f
0
8
�
a4
w
4�
i
Robert J. Amoruso, P.E.
FL P.E. No. 49752
4 \ t aae
Digitally signed by
RobertJAmoruso .
Date: 2021.02.18
12:08:59-05'00'
1/4' MAX SHIM
1/4' MAX SHIM
p
`
1/2• MIN. EDGE:l11ST.
•. '
1/2'-MIN EDGE DIST .
m
a.
.
2X WOOD FRAME
2X W000 FRAME
(BY OTHERS)
(BY OTHERS) .
..•
B
#8 WOOD SCREW
#8 WOOD SCREW
'
INSTALLATION ANCHOR
INTERIOR
INTERIOR
INSTALLATION ANCHOR
m
;
314
MIA
IN.
V
o
1'MIN.
\ \
A�\�A��
Null
EMBEDMENT .
C/]
Z
w
C
92
�'
V
EMBEDMENT
v�iG Vl
SEALANT TAPE TO BACK :
SIDE OF MOUNTING FIN
EXTERIOR
EXTERIOR SEALANTTAPETO:BACK
VIR
•+
o
SIDE OF MOUNTING FINON
�r
m
ca
cc
Iwo
z
z—
HORIZONTALL SECTION
F HORIZONTAL SECTION
'�'
a
E .
WOODFRAMESUBSTRATB
WOOD sUBsztw
p
a�
`r ¢
,p�
z
e
X
m
g!�
14 GA. MIN. SQUARE
14 GA MIN. SQUARE
3/8• MIN. EDGE DIST. "
STEELTUBING(BY :
OTHERS)
'. INTERIOR
- STEEL TUBING (BY
OTHERS)
INTERIOR .
3/8' MIN, EDGE DIST. '
@
#8 TAPPING.SCREW'
tI8_ TAPPING SCREW
INSTALLATION ANCHOR
MIX 314' SMS
INSTALLATION ANCHOR
\
\\
THREE (3) THREAD r
THREE (3) THREAD ''
MIN. PENETRATION
MIN. PENETRATION
Robert J.Amoruso,P.E
SEALANT TO BACK
L.A
EXTERIOR;
EXTERIOR
FIr P.E. No; 49752.
SIDE OF MOUNTING FIN
SEALANT TAPE -TO BACK
w^^ ••m
eF a°+
SIDE OF MOUNTING FIN
•
.'
:
: :
: : : : : _ : _ :
-H HOON�TAL SECTION
: fool eheor€.
(D'�HORIZONTAL SECTION
Digitally signed by.
STEE TMING SUBSTRATE
RoberfJ Amoruso ..
Date: 2021.02.18 .
12:09:1.0-05'00'