Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - SWINGING EXTERIOR DOORt u,rarr ' fYl 1 C� ® Professional- , , ,- Bcrs Home I Log In User Registration HotToplcs. Submit Surcharge I Stats & Facts Publications I Contact Us j BCIS Site Map I Links I Search Florida . .. prac Product Approval 1 USER: Public Usv .. . Product uR Approval Menu > Product or Wlication Search> ppiiiag on List > Application Detall FL #'. FL17996-R2 Application Type Revision Code Version 2020 Application Status Approved . *Approved by DBPR: Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Elixir Door and Metal Company Address/Phone/Email 1215 Pope -Drive - . Douglas,: GA 31533 (912).493-2215 . ryarberry@elixirdmc.com Authorized Signature. Randall Yarberry .. ryarberry@eliXi rdmc;con Technical Representative FTC Product Design Group Address/Phone/Email PO Box 5.20775 Longwood, FL 32752 (321) 690-1788 info@ptc-corp Quality Assurance Representative. Address/Phorie/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method. Certification Mark or Listing Certification Agency- American Architectural Manufacturers Association Valldated By American Architectural Manufacturers Association Referenced Standard and Year (of Standard) Standard- Year ASTM E330 2002 ASfM E330 2014 Equivalence of Product Standards CertiFled By Florida Licensed Professional Engineer or Architect FL17996 R2 Eauly EER 2244 Rev3 ss:Ddf Product Approval Method Method 1 Option A Date Submitted 02/19/2021 Date Validated Date Pending FBC Approval Date Approved Surimmary of ProAueta 62/22/2021 02/28/2021 FL # Model, Number or Name Description 17996.1 Series,202-20SSteel Door Series•202-20S Steel O.S. Doorw/Vertical Slider Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17996 R2 C CAC 19359 Elixir - 202-20S OS Door (jbJ, Approved for use outside HVHZ: Yes ASTM Jan. 202Ligdf .Impact Resistant: No Design Pressure:.+38.7/-32 Quality Assurance Contract Expiration, Date 07/11/2024 Other: Installation Instructions. FL17906 R2 II •ELIX0034 Rev B Model-202-205 ss.odf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1642 Rev4 ss.odf Created by Independent Third Party: Yes 17996.2. Series 230 W9 Steel Door Series 230 W9. Steel O.S. Door w/ Cottage Window Limits of Use ... CertiRcation.Agency Certificate . Approved for use in HVHZ: No Approved for use outside HVHZ: Yes - Impact Resistant: No FL17996 R2 C CAC 19346 Elixir - 230-W9 OS Door 11bi, ASTM ]on. 2021.o�P - Quality Assurance Contract Expiration Date -Design Pressure: +25.3/-25.3 07/11/2024 Other: Installation Instructions FL17996 R2 II ELIX0033 Rev B Model 230 W9 .ss.odf Verified By: RobertJ. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2-AE PER, 1642,Rev4 ss.hdf Created by Independent Third Party: Yes 17996.3 . Series 402-14 Vinyl Steel Out -Swinging Regular Door -14" x 14" Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No Approved for use outside•HVHZ: Yes FL17996 R2 C CAC 19349 Elixir - 402-14 OS Door ej j, ASTM )an,2021.odf " Impact Resistant: No. Quality Assurance Contract Expiration Date. Design Pressure:-+66/-56 08/26/2025. .Other: Installation Instructions FL17996 R2 Is ELIX0650 REV-B:OS MODEL 402-14 ss.pdf Verified By: Robert J. Amoruso, PE FL.PE No: 49752 Created by Independent Third Party: Yes, Evaluation Reports FL17996.R2 AE PER 1951 Rev3 ss.g_df Created by Independent Third Party: Yes 17996.4 Series 402-20S Vinyl Steel Out -swinging Regular Door - 20" slider window Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL17996 'R2 C 'CAC 19358 Elixir - 402-20S.05 Door (],W, Approved for use outside HVHZ: Yes ASTM tan. 2021.odf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +66/-56 08/26/2025. Other: Installation Instructions FL17996 R2 II ELIX0051 REV-B OS MODEL 402 20S ss odf Verified. By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes . Evaluation Reports- FL17996 R2 AE PER 1951 Rev3 ss.od( ride endent Third Party: Yes 17996.5 Series 407 Vinyl Steel Out -Swing Regular Door - Blank (no window) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17996 R2 C CAC 19345 Elixir - 407 OS Door (1b) ASTM Approved for use outside HVHZ: Yes Jam 2021.2 ff Impact Resistant: No Quality. Assurance Contract Expiration Date Design Pressure: +56/-50 08/19/2025 Other: Installation Instructions FL17996 R2 II ELIX0052 REV-B OS MODEL 407 ss.r�df Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 RZ AE PER 1951 Rev3ss.pdf Created by Independent Third Party: Yes 17996.6 Series 430 WJ Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ:'Y4ds impfict Resistant: No Design Pressure: +56/-SO Other: Vinyl Steel Out -swinging Regular Door.- 9-Lite Window (1'8" x Yd") Certification Agency Certificate FL17996' R2 C CAC 19344 Elixir - 430=W9 OS Do& (1b) 0 . Quality Assurance Contract Expiration Date 08/25/2025 Installation Instructions FL17996 R2 II ELIX0053 REV-B OS MODEL 430-W9 ss od Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation:Reports• FL17996 R2 AE PER 1951 Rev3 gWAF. Created by Independent Third Party: Yes 17996.7 Series 6400 W9 Cottage Series 6400-W9 Non -Impact Inswing Painted Steel Door w/Storm Door ' Limits of Use Approved for use in HVHZ:. No Certification Agency Certificate FL17996 R2 •C CAC 19352 Elixir - 6400-1N9 IS Door'w-Srnrm 'Approved for use outside HVHZ:.Yes Impact Resistant: No Design Pressure: +66.7/-56.7 (1b) ASTM Jan. 2021.u� Quality Assurance Contract Expiration Date 09/07/2024 Other: -Installation Instructions FL17996 112- II .ELIX0056 Rev-8 IS MODEL 6400-W9 WM STORM DOOR ss.pdf- Verified By: Robert J. Amoruso, PE FL PE No. 49752 . Created by IndependentThird.Party.: Yes Evaluation Reports FL17996 R2-AE PER'.1954 Rev3 ss.o- Created by Independent Third Party: Yes.. 17996.8 Series 7500 Oval Series 7500:Non-Impact Inswing Vinyl Laminated Steel Door w/Storm Door and PVC Jambs Limits of.Use Approved for use in HVHZ: No 'Approved for use outside HVHZ* Yes Impact Resistant: No Design Pressure: +50/-50 Other:. Certification Agency Certificate . FL1706 R2 C CAC 19348 Elixir - 7500 IS Door w-Storm f 1,_ASTM Jan. 2021.odf Quality Assurance Contract Expiration Date 08/23/2024 Installation Instructions. FL17996 R2 II ELIX0060 Rev-B-IS MODEL STR 7500 OVAL WITH -STORM DOOR ss.odf- Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1955 Rev3 ss.odf Created by Independent Third Party: Yes --] 17996.9 Series 8406 W9.Cottage Series 8400-W9 Non -Impact Oval Inswing Vinyl Laminated Steel Door w/Storm Door Limits of Use.. Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Certification Agency Certificate FL17996 R2 C CAC 19353 Elixir - 8400-W9 IS Door w-Storm ( lb) ASTM ]an. 2021.pdf -Impact Resistani: No Design Pressure: +50/-50 Other: Quality Assurance Contract Expiration Date .09/07/2024 Installation Instructions FL17996' R2 II ELIX0057 Rev-5 IS MODEL 8400 W9' OVAL WITH STORM DOOR ss.odf Verified By: Robert J: Amoruso, RE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1954 Rev3 ssmpdf Created by Independent Third Party: Yes 17996.10 Series 9000. Series 9000 Non -Impact Inswing Vinyl Laminated Steel Door w/Storm Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure:.+50/-50.7 Other: Certification Agency Certificate FL17996 112 C CAC 19374 Elixir.- 9000 IS Door w-Storm lb-ASTM ]an. 2021.pdf ' Quality -Assurance Contract Expiration bate .09/06/2024 Installation Instructions FL17996 R2 II ELrX0058 Rev-BiS BLANK 9006 DOOR W. STORM DOOR ss.odf Verifed By: ,Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1954 Rev3 ss odf. Created by Independent Third Party: Yes 17996.11 Series 9400-W9 Cottage Series 9400-W9 No Inswing Vinyl Laminated Steel Door w/Storm Door Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Certification Agency Certificate FL17996 R2 C CAC 19350 Elixir - 9400=W9 IS Done w-Storm (1b) ASTM Jan: 2021:0d� Quality. Assurance Contract Expiration Date 09/06/2024 Other: Installation Instructions FL17996 R2 II EUX0059 Rev-B IS MODEL 9400-W9 COTTAGE W: STORM DOOR ss,odf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by IndependentTh.ird Party: Yes Evaluation Reports FL17996 R2 AE PER 1954 Rev3 ss.pdf Created by Independent Third Party: Yes 17996.12 Series AFIF7N Series AFIF7N Non -Impact IS Fiberglass"Doar Limits of Use Approved for use in No Approved for use outside HVHZ: Yes Certification Agency Certificate FL17996 R2 C CAC 19351 Elixir - AFIF7N IS Door ib) ASTM ]an. 2021,odf Impact Resistant: No Design Pressure: +38J/-38.7' Quality Assurance Contract Expiratiod Date 08/21/2024 Other:, Installation. Instructions. FL17996 R2 H ELIX0040 AFIM-BFIFM RevB ss.pdf Verified By: Aobert J,. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2• AE. PER' 1952 Rev3 ss,pdf Created by Independent Third Party: Yes 17996.13 Series-AVIM Series AVIF7N, Non -Impact IS Steel Door Limits of Use Approved for use in HVHZ: No Certification Agency Certificate FL17996 R2 C CAC 19356 Elixir - AVIF7N IS Door (ih�• ASTM ]an,.2021.od Quality Assurance Contract Expiration Date. 07/22/2025 Approved for use outside HVHZ.-Yes Impact Resistant: No Design Pressure: +38/-38 'Other: ,Installation Instructions FL17996' R2 •II. ELD(0047 AVIF7N RevB ss,gdf 'Verified By:.Robert J:'Amoruso, PE FL PE No: 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996'112.AE PER 1953 Rev3 ss.odf . Created by Independent Third Party: Yes 17996.14 Series BFIF7N Series BFIF7N Non-ImpactIS Fiberglass Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No . Approved for use outside HVHZ: Yes FL17996 R2 C 'CAC 19357 Elixir - BFIF7N. IS Door.w-Side Lites 1b ASTM Jan. 2021,Ddf Impact Resistant: No .. Design Pressure: +38.7/-38.7 Quality Assurance Contract Expiration Date '08/21/2024 Other: Installation Instructions FL17996 R2 3I ELTX0040 AFIF7N-BFIF7N RevB ss.odf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes .Evaluation Reports FL17996 R2 AE PER 1952 Rev3 ss.odf Created by Independent Third Party: Yes 17996AS Series BVI63S Series BVI63S Non -Impact Single Inswing Door w/Fixed Lite Insert and Outswing Storm Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Certification Agency Certificate FL17996 R2 C CAC EXR BVI63S E331)-olus5,odf Quality Assurance Contract Expiration Date 12/17/2021 Design Pressure: +65/-65 Installation Instructions Other: FL17996- R2 II ELIX6061 BVI63S RevB ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER .2244"ReV3 ss:Ddf . Created by Independent Third Party: Yes 17996.16 Series BVIF7N Series BVIF7N Non -Impact IS Steel Door Limits of Use Approved for -use in HVHZ: No Approved for use outside HVHZ: Yes Certification Agency Certificate FL17996 R2 C CAC 19354 Elixir- BVIF7N IS Door (11) ASTM )an. 2021.odf. •Impact Resistant: No Design Pressure: +40/-40 Quality Assurance Contract Expiration Date 07/29/2025 Other: Installation Instructions FLi7996 R2 II. ELIX0049 BVIF* BVIF7S RevB ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by IndependentThird'Party: Yes: Evaluation.Reports FL17996 R2 AE PER 1953 Rev3 ss.Ddf. v Created by Independent Third Party: Yes' 17996.17 Series BVIF7S : Series BVIF75Non-Irnpact1S Steel Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL37996 '112 C CAC 19355 Elixir - BVIF7S IS Door tv-Storm Approved for use outside HVHZ: Yes (1b) ASTM Jan. 2021.Ddf Impact Resistant: No Quality Assurance:Contract Expiration Date Design .Pressure: +50/-50 07/29/2025 Other: installation Instructions . FL17996" R2. II ELIX0049 BVIF7N BVIF7S RevB ss,pdf Verified By: Robert J. Amoruso, PE FL PE Na. 49752. Created by Independent Third Party: Yes Evaluation Reports FL17996 .R2 AE PER 1953 Rev3 ss.Ddf Created by Independent Third Party:. Yes ContactUs :: 2601 Blair Stone Road: Tallahassee FL 32399 Phone:850-4B7-1024 The State of Florida Is an AA/EEO.employer. Copyright 2007-2013 State of Florida.:: Prlvacv' Statement :: AccessiblPIM Statement :: Refund Statement Under Florida law; email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to.thls entity: Instead, contact the office by phone oi• by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florlda Statutes, effective October 1, 2012, licensees licensed "under Chapter, 455, F.S. must provide the Department with an email address if they have one. The emails - . provided may be used foroffldal communication with the licensee. However email addresses are public record. If you do not.wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick h=. .. Product Approval Accepts: o'er a� Credit Card Safe ELIXIR DOOR & METALS CO. MODEL-407 NON -IMPACT OUTSWING VINYL LAMINATED -STEEL: DOOR INSTALLATION ANCHORAGE DRAWING. GENERALNOTES:" 1. THE PRODUCT ANCHORAGE SHOWN HEREIN IS DESIGNED - S.IN AREAS WHERE WINDBORNE DEBRIS PROTECTION TO COMPLY WITH THE CURRENT EDITION OF THE REQUIREMENTS EXIST, USE OFAN IMPACT PROTECTIVE FLORIDA BUILDING CODE (FSC) EXCLUDING HIGH SYSTEM COMPLYING WITH THE FBC REQUIREMENTS FOR VELOCITY HURRICANE ZONE AND THE DESIGN WINDBORNE DEBRIS REGIONS IS MANDATORY FOR THE PRESSURE(S) STATED HEREIN. - PRODUCTHEREIN. 1a THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED. 6. FRAME MATERIAL' ALUMINUM ALLOY6063.76 " UPON SIGNED AND SEALED TEST REPORT DOOR PANEL MATERIN-:.09 M6- VINYL LAMINATED, CONSTRUCTION CONSULTING LABORATORY REPORT N GALVANIZED STEELAIS' SKIN WT URETHANE FOAM CORE. CCL-19-167 AND ASSOCIATED LABORATORY STAMPED ' DRAWINGS. .. .. 7. GLASS MEETS THE REQUIREMENTS OF ASTM E1300.12AE1. 1b. TESTED TO ASTM E330-14. B. DESIGNATIONS'X' STAND FOR THE FOLLOWING; 2. ADEQUACY OF THE EXISTING STRUCTURAL 2X FRAMING X: OPERABLE PANEL OR STEEL FRAMING AS A MAIN WIND FORCE RESISTING O: FIXED PANEL SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCTLOADS TO THE 9. HARDWARE. " FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER A HALF HINGES. (4) 6063-TS EXTRUDED ALUMINUM OR ARCHITECT OF RECORD. B. LATCH LOCK: KEYED - C. DEAD BOLT: SINGLE CYLINDER ,.3. WAND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE 10. SEE SHEET? FOR DESIGN PRESSURE CHART STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE - - . RESPONSIBILITY OF THE ENGINEER OR ARCNITECT OF 11; IF WATER INFILTRATION REQUIREMENT EXISTS, UNIT MUST. RECORD.. BE INSTALLED BENEATH AN OVERHANG MEETING THE. CURRENT EDITION OF THE FLORIDA BUILDING CODE - 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE BUILDING AND RESIDENTIAL VOLUMES. GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS -' FOR A SPECIFIC SITE IF SITE CONDITIONS CAUSE. INSTALLATION TO DEVIATE FROM THE REQUIREMENTS - DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT' - SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. - 'DESIGN PRESSURE RATING (PSF) IMPACT RATING WHERE WATER INFILTRATION REQUIREMENT IS NEEDED WHERE WATERINFILTRATON REQUIREMENT IS NOT NEEDED NONE - SEE GENERAL NOTE 11 +501-5.0- TABLE OF CONTENT SHEET DESCRIPTION 1 GENERAL AND- INSTALLATION NOTES 2 ELEVATION, ANCHORING LAYOUT 3 VERTICAL CROSS SECTIONS 4 HORIZONTAL • CROSS SECTIONS INSTALLATION NOTES: 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH S. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE ANCHOR LOCATION: WALL FINISHES. INCLUDING BUT NOT LIMITED, TO - STUCCO, FOAM, BRICK VENEER AND SIDING. 2. THE INSTALLATION ANCHORS ATTHE SPACINGS SHOWN . ARE THE MINIMUM NUMBER OF ANCHORS AND MAXIMUM 6. INSTALLATION ANCHORS SHALL BE INSTALLED IN SPACINGS TO BE USED FOR PRODUCT INSTALLATION. ACCORDANCE WITH ANCHOR MANUFACTURERS" INSTALLATION INSTRUCTIONS AND ANCHORS SHALL 3.SHIMASREQUIRED ATEACH INSTALLATION ANCHOR. NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS' WITH LOAD B EARI NG SHIMCS).'MAXIMUM ALLOWABLE THAN THE MINIMUM STRENGTH SPECIFIE13INTHE SHIM SIZE OF 114INCH. SHIM WHERE SPACE OF 1116INCH 'ANCHOR SCHEOULE' THIS SHEET. OR GREATER OCCURS. SHIM(S)SHALL BECONSTRUCTED. OF HIGH DENSITY PLASTIC OR BETTER. 7-.INSTALLATION ANCHORS AND ASSOCIATED HARDWARE' MUST BE MADE OF CORROSION RESISTANT MATERIAL 4: ANCHORS FOR INSTALLATION INTO WOOD FRAMING OR " OR RAVE A CORROSION RESISTANTCOATING. . 14GA. MINIMUM STEEL FRAMING SHALL SEAS SHOWN IN " 'ANCHOR SCHEDULE'THIS SHEET. ANCHOR SCHEDULE DOORFRAME MANUFACTURER ,EMBEDMENT EDGE 'ANCHOR CAPACITIES SUBSTRATE TYPE TYPE SIZE ANDIOR pN)1�1 DISTANCE BASEDON SPECIFICATION _- (IN)111a SHEET ' MIN..3 ' METALUSTEEL ASME 818.5.4 - THREADS , MIN, 33 KSI YIELD TUBING 14 GA FIN (Z-BAR) PAN HEAD NO: 8 PAST INSIDE 318, MIN (TAPPING SCREW) SURFACE OF STRNEGTH THICKNESS -SUBSTRATE . ANSI818.6.1. 2X WOOD (WOOD SCREW) WOOD WITH AMINIMUM FRAMING FIN (Z-BAR) PAN HEAD NO.8 . OR 1' 1/2' - SPECIFIC GRAVITYOF- . -ASME B18.6A-, 0.42. (TAPPING SCREW) NOTES: 1)-FDR WOOD OR TAPRNG SCREWS IF SPLITING IS A CONCERN, DRILL 0.082E PILOT HOLE (DRILL SIZE45), 2)EDGE DISTANCEMEASUi® FROM BTiERSIDE OFANCHOR TO EDGE OFSUBSTRATE T W O 0 Robert J. Amoluso, P.E. FL P.E. No.49752 W`>fVi �WUH.� O,ur Digitally signed by RobertJ Amoruso Date: 2021.02.18 12:08:03-05'00' 38 1• MAX. OA FRAME WIDTH 36 MAX. : v. . DOOR PANEL S o WIDTH W MAX.. O.C. (1YP.) . . B D . 4• MAX. (1 YP) {.— 4' MAX. (TYP ). m H O N v 4 .4 3. )� �y N X•u. F F (�]. c� N EdN 4 4. G' X: G LOCK ASSEMBLY IS LOCATED APPROX., - : - G'MAX - -C4 • o s c , 821J4" 60� ' 37•ABOVE BOTTOM OF DOOR LEAF H g } 0.0 (TYP.) 4 4 MAX OA MAX, E O AND THE DEADBOLTASSEMBLY, p FRAME DOOR 4 4 APPROX. 41' ABOVE BOTTOM OF DOOR X HEIGHT PANEL LEAF. SEE STRIKE DETAILS THIS O" C E~ Z m HEIGHT .. SHEET. W o �LL c a1° a v zQ _ rZ',, Zzz. Et 37' m. FOUR HALF HINGES. 3' + A O s as AND 21' FROM EACH SILLANCHOR SPACING i16 A C . END OF THE DOOR : SAME AS HEAD•SPACING �4 PANELSECURED 3 .3 BYNBX3/4•SCREINS ANCHOR LAYOUT W yell ELEVATION QYPJ .. .. EXTERIOR VMW .. . EX'IBRIOR VIEW .. - ANCHORING NOTES: '1. MINIMUM NUMBER OF AN IN JAMBS IS 14. ANCHOR SPACING.VARIES, BUT NOT TO EXCEED 6' MAXIMUM O.C. . 118x318`WOOD.. I I' SCREW MUSTTAPPING I I I . - .. RobeR J. Amoroso, P.E.- SCREW. 2.. MINIMUM NUMBER OF IN SILL SCREW SUFFICIENT LENGTH TO IS 6. ANCHOR SPACING VARIES, BUT NOT TO FL P.E No.A9752 . i I PENETRATE (3) THREADS. EXCEED 6• MAXIMUM O.C. . I L I MINIMUM BEYOND STEEL - Digitally-. TUBE. signed by Robert) ENTRY DOOR ENTRY.DOOR STRIKE DETAIL.. STRIKE DETAII. _ e 1 Dmon�so WOOoeRAM ESUB mre sres.•nnwasua iuT-z 'q "i ate: 2021.02.18 12:08:47 . -05,00, T MIN. EMBEDMENT—[— MBEDMENT #8 WOOD SCREW INSTALLATION ANCHOR 2X WOOD FRAME (BY OTHERS)' 1f2' MIN. SEALANT TAPE TO BACK. EDGE DIST. SIDE OF MOUNTING FIN 1/4' MAX SHIM EXTERIOR INTERIOR 1 VERTICAL SECTION WOOD FRAME SUBSTRATE EXTERIOR INTERIOR �1/4" MAX SHIM SEALANT TAPE TO BACK SIDE OF MOUNTING FIN�� 1/2' MIN. EDGE DIST. 2X WOOD FRAME (BY OTHERS) 1' MIN. EMBEOMENT-- 08 WOOD SCREW INSTALLATION ANCHOR SECTION 0VERTICAL WOOD FRAME SUBSTRATE THREE (3).THREAD MIN.PENETRATION. #8 TAPPING SCREW INSTALLATION ANCHOR SEALANT TAPE TO BACK 3/8' MIN. SIDE OF MOUNTING FIN • EDGEDIST. 14 GA MIN. SQUARE STEEL TUBING (BY OTHERS) EXTERIOR INTERIOR (D-%RCAL SECTION EL TUBINO SUBSTRATE ,EXTERIOR INTERIOR . /14 GA. MIN, SQUARE STEEL TUBING (BY OTHERS) 3/8' MIN. SEALANT TAPE TO BACK EDGE DIST. SIDE OF MOUNTING FIN #8 TAPPING SCREW ... -THREE(3)THREAD INSTALLATION ANCHOR MIN. PENETRATION C VERTICAL SECTION sTEELIMINGSUBSTRATE , C a'. g O N_ N U of c t,. o W M Z. ¢ Ems+ Soo a is o,; U<Vwid co d _� w I S C 0 a, zi-'t¢ ZZ� 111 O N-, OU R f 0 8 � a4 w 4� i Robert J. Amoruso, P.E. FL P.E. No. 49752 4 \ t aae Digitally signed by RobertJAmoruso . Date: 2021.02.18 12:08:59-05'00' 1/4' MAX SHIM 1/4' MAX SHIM p ` 1/2• MIN. EDGE:l11ST. •. ' 1/2'-MIN EDGE DIST . m a. . 2X WOOD FRAME 2X W000 FRAME (BY OTHERS) (BY OTHERS) . ..• B #8 WOOD SCREW #8 WOOD SCREW ' INSTALLATION ANCHOR INTERIOR INTERIOR INSTALLATION ANCHOR m ; 314 MIA IN. V o 1'MIN. \ \ A�\�A�� Null EMBEDMENT . C/] Z w C 92 �' V EMBEDMENT v�iG Vl SEALANT TAPE TO BACK : SIDE OF MOUNTING FIN EXTERIOR EXTERIOR SEALANTTAPETO:BACK VIR •+ o SIDE OF MOUNTING FINON �r m ca cc Iwo z z— HORIZONTALL SECTION F HORIZONTAL SECTION '�' a E . WOODFRAMESUBSTRATB WOOD sUBsztw p a� `r ¢ ,p� z e X m g!� 14 GA. MIN. SQUARE 14 GA MIN. SQUARE 3/8• MIN. EDGE DIST. " STEELTUBING(BY : OTHERS) '. INTERIOR - STEEL TUBING (BY OTHERS) INTERIOR . 3/8' MIN, EDGE DIST. ' @ #8 TAPPING.SCREW' tI8_ TAPPING SCREW INSTALLATION ANCHOR MIX 314' SMS INSTALLATION ANCHOR \ \\ THREE (3) THREAD r THREE (3) THREAD '' MIN. PENETRATION MIN. PENETRATION Robert J.Amoruso,P.E SEALANT TO BACK L.A EXTERIOR; EXTERIOR FIr P.E. No; 49752. SIDE OF MOUNTING FIN SEALANT TAPE -TO BACK w^^ ••m eF a°+ SIDE OF MOUNTING FIN • .' : : : : : : : : _ : _ : -H HOON�TAL SECTION : fool eheor€. (D'�HORIZONTAL SECTION Digitally signed by. STEE TMING SUBSTRATE RoberfJ Amoruso .. Date: 2021.02.18 . 12:09:1.0-05'00'