Loading...
HomeMy WebLinkAboutProject Information -LUCUrS ST. LUCIE �� ORKI�`, ST LUCIE COUNTY ROOFING PERMIT INFORMATION Florida Building Code 7th Edition (2020) J A N 2 q 2r'22 Based on Section 1525 of the Florida Building Code-Building INSTRUCTION PAGE ST. Lucie County, Permitting COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A, B,C 1,2,3,435,6,7 Prescriptive BUR-RAS 150 A, B,C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4;5,6,7 Metal Roofs A,B, D 1,2,3,45AT Wood Shingles and A,B,D 1,2,4,5,6,7 Shakes Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2 2—e-_>( c!� 4 O 2. From Product Approval: REVIEWED FOH Front Page CODE COMPLIMN . ,, Specific System Description ��rr Specific System Limitations ST. LUCIE COUNT Y General Limitations BCC Applicable Detail Drawings 3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128 4. Other Component of Product Approval S. Municipal Permit Application 6. Owners Notification for Roofing Considerations(Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18,2021 ST. LUCIE WORKS Section A (General Information) Master Permit No. Process No. Contractors Name: Doing Roofing,.Co.-Arturo Reynoso License# CCC1332511 / 32144 Job Address 208 NE Bracken Rd, Port St Lucie, FL 34983 ROOF CATEGORY Vow Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles ❑Asphaltic Shingles ❑Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE- 0 New roof ❑ Repair ❑ Maintenance 'Reroofing ❑Recovering -ROOF SYSTEM INFORMATION Low Slope Roof Area(SF) 2,385 Steep Sloped Roof Area(SF) 0 Total(SF) 2,385 Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. ___j -F-Em roi 7fof N K i r IA I %J11 " L T_f J � Prepared by® roofr Length Measurement Report 208 NE Bracken Rd, Port St. Lucie, FL 34983, USA om Eaves 222ft 1 in Valleys 13ft 6in Hips 32ft 1 Oin Ridges Oft Oin o Rakes Oft Oin ... Wall Flashing Oft Oin Von Step Flashing Oft Oin Transitions 264ft 7in Unspecified Oft Oin 42 M M � N N V L N N N N 35 w Note:The above diagram contains measurements that have been rounded up.6 and 9 are written•6 and.•9 to avoid confusion. Some edge length totals have been hidden from the diagram to avoid overcrowding.Flashings are depicted as dotted lines. This report was prepared by Roofr.Copyright©2021 Roofr.com I All rights reserved. 4 ST. LUCIE , � � ��{ Section C(Low Slope Roof) Surfacing: N/A Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment: manufacturer Zone 1':`"oc @ Lap,#Rows ® moo (If a component is not used,identify as"NA") Zone 1:—"oc @ Lap,#Rows ® "o0 System Manufacturer: Polyglass USA Zone 2:—"oc @ Lap,#Rows ® moo Product Approval No.: FL1654-R27 Zone 3:_.._."oc @ Lap,#Rows ® "oo Number of Fasteners Per Insulation Board: N/A Design Wind Pressures,From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3: -27.6 -27.6 -51.0 -69.6 Zone 1':_Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Max. Design Pressure,from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping, system: 97•5 Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing,Coping, Etc.. Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base Type:Plywood Flashing,Component Material,Material'Thickness,Fastener Gauge Thickness: N/A Type,Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. Slope: 0.25/12 Anchor/Base Sheet&No.df Ply(s): N/A Anchor/Base Sheet Fastener/Bonding Material: FT. N/A Insulation Base Layer: N/A Base Insultation Size and Thickness: N/A Parapet Base Insulation Fastener/Bonding Material: Helght N/A Top Insulation Layer: N/A Top Insulation Size and Thickness: N/A 10 FT. Top Insulation Fastener/Bonding Material: N/A Mean Base Sheet(s)&No.of Ply(s): 1 Roof Base Sheet Fastener/Bonding Material: Height Elastoflex SA V Ply Sheet(s)'&No.of Ply(s): N/A Ply Sheet Fastener/Bonding Material: N/A Top Ply: 1 Top Ply Fastener/Bonding Material: Polyflex SA P L