Loading...
HomeMy WebLinkAboutSoprema_2569.1-R22_CV2020_4.1 TU HT6/24/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsKQFEnckB108Erx1Ud3xYlr7amGvvoArqgkU4EylLatg%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL2569-R22 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Soprema, Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville, NON-US 00000 (819) 478-2400 memathieu@soprema.ca Authorized Signature Marc-Etienne Mathieu memathieu@soprema.ca Technical Representative Marc-Etienne Mathieu Address/Phone/Email 1688 Jean-Berchmans-Michaud Drummondville, NON-US 00000 (819) 478-2400 Ext 3327 memathieu@soprema.ca Quality Assurance Representative Jean-Francois Cote, Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888) 811-3145 jfcote@soprema.ca Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert J. M. Nieminen Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/21/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL2569_R22_COI_2021_01_COI_NIEMINEN.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D1970 2015 ASTM D4601 2012 ASTM D4798 2011 FM 4474 2011 FRSA/TRI Sixth Edition 2018 TAS 103 2020 UL1897 2015 6/24/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsKQFEnckB108Erx1Ud3xYlr7amGvvoArqgkU4EylLatg%3d%3d 2/2 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/19/2021 Date Validated 04/19/2021 Date Pending FBC Approval 04/26/2021 Date Approved 06/08/2021 Summary of Products FL #Model, Number or Name Description 2569.1 Soprema Roof Underlayments for use in FBC HVHZ jurisdictions Self adhering roof underlayments Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER Section 5 for Limits of Use. Installation Instructions FL2569_R22_II_2021_04_19_FINAL_ER_SOPREMA_HVHZ_FL2569- R22.pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL2569_R22_AE_2021_04_19_FINAL_ER_SOPREMA_HVHZ_FL2569- R22.pdf Created by Independent Third Party: Yes 2569.2 Soprema Roof Underlayments for use in FBC non-HVHZ jurisdictions Self adhering roof underlayments Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-150 Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The design pressure noted herein pertains to underlayment systems used beneath adhesive-set tile systems. Refer to ER Section 5.8.3 for details. Installation Instructions FL2569_R22_II_2021_04_19_FINAL_ER_SOPREMA_NON- HVHZ_FL2569-R22.pdf Verified By: Robert Nieminen, P.E. PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL2569_R22_AE_2021_04_19_FINAL_ER_SOPREMA_NON- HVHZ_FL2569-R22.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT Soprema, Inc. 1640 rue Haggerty Drummondville, Québec J2C 5P8 Canada (819) 478-2400 Evaluation Report S18010.06.09-R20 FL2569-R22 (NON-HVHZ) Date of Issuance: 06/15/2009 Revision 20: 04/10/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product descr ibed herein has been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments for use in FBC non-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 04/19/2021. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC NEMO|etc. NEMO ETC, LLC Evaluation Report S18010.06.09-R20 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R22 (NON-HVHZ) Soprema Roof Underlayments Revision 20: 04/19/2021 Page 2 of 8 ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Soprema Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.3.1 Wind resistance UL 1897 2015 1507.1.1, 1507.2.4, 1507.2.9.2 / R905.1.1, R905.2.8.2 Material standard ASTM D1970 2015 1507.3.3 / R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD (TST6049) FRSA/TRI 04-12 (MS) S43530.02.14-1-R1 02/21/2014 ERD (TST6049) ASTM D1970 (QC) S44870.04.14-3 04/02/2014 ERD (TST6049) ASTM D1970 (OH) S44870.04.14-1 04/10/2014 ERD (TST6049) ASTM D1970 (MS) S44870.04.14-4 04/10/2014 ERD (TST6049) ASTM D1970 (OH) S40540.10.14 10/31/2014 ERD (TST6049) Tensile Adhesion / Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015 ERD (TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017 NEMO (TST6049) ASTM D1970 / TAS 110 (QC) SOPC-SC8970.08.15-R1 04/25/2018 NEMO (TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018 NEMO (TST6049) Tile Slippage 4S-SOPC-18-002.09.18 09/21/2018 NEMO (TST6049) ASTM D4798/D1970 (OH & MS) 4S-SOPC-18-002.05.19.A 05/31/2019 NEMO (TST6049) Tensile Adhesion / Long Term Aging 4p-DOW-19-SSLAP-01.A.R2 02/10/2020 NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-19-SSUDL-04.A 03/12/2020 NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-20-SSUDL-01.A 01/07/2021 NEMO (TST6049) ASTM D1970 (MS) 4j-SOPC-21-SSUDL-01.A 04/19/2021 PRI (TST5878) ASTM D1970 (MS) SOP-064-02-01 12/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL, LLC (QUA9625) Quality Control MLA File No. R16814 12/10/2015 UL, LLC (QUA9625) Quality Control MLA File No. R27605 05/08/2019 UL, LLC (QUA9625) Quality Control Service Confirmation 06/29/2020 UL, LLC (QUA9625) Quality Control Florida BCIS Current 4. PRODUCT DESCRIPTION: Product Material Standard Plant(s) Description 4.1 LASTOBOND TU HT ASTM D1970 and FRSA/TRI 09-18 Gulfport, MS self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof underlayment 4.2 Tri-Built S/A HT TU Underlayment ASTM D1970 and FRSA/TRI 09-18 Gulfport, MS self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof underlayment NEMO|etc. NEMO ETC, LLC Evaluation Report S18010.06.09-R20 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R22 (NON-HVHZ) Soprema Roof Underlayments Revision 20: 04/19/2021 Page 3 of 8 Product Material Standard Plant(s) Description 4.3 LASTOBOND Shield ASTM D1970 Drummondville, QC self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch 4.4 RESISTO SA SMOOTH PLY 40 ASTM D1970 Drummondville, QC self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment 4.5 LASTOBOND Shield HT ASTM D1970 Drummondville, QC self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment 4.6 LASTOBOND Pro HT-N ASTM D1970 Drummondville, QC self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch 4.7 LASTOBOND Pro HT-S ASTM D1970 Drummondville, QC self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment 4.8 EnviroShield ASTM D1970 Drummondville, QC self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment 4.9 LASTOBOND Eco ASTM D1970 Drummondville, QC Gulfport, MS Wadsworth, OH self-adhering, glass-mat reinforced, sand- surfaced, SBS modified bitumen roof underlayment 4.10 LASTOBOND Smooth Seal HT ASTM D1970 Gulfport, MS Wadsworth, OH self-adhering, glass-mat reinforced, film- surfaced, SBS modified bitumen roof underlayment 4.11 Tri-Built Smooth HT S/A Underlayment ASTM D1970 Gulfport, MS Wadsworth, OH self-adhering, glass-mat reinforced, film- surfaced, SBS modified bitumen roof underlayment 4.12 PrimeSource Grip-Rite Smooth Seal HT ASTM D1970 Gulfport, MS Wadsworth, OH self-adhering, glass-mat reinforced, film- surfaced, SBS modified bitumen roof underlayment 4.13 RESISTO LB1236 ASTM D1970 Drummondville, QC Gulfport, MS Wadsworth, OH self-adhering, glass-mat reinforced, sand- surfaced, SBS modified bitumen roof underlayment 4.14 TRI-BUILT Sand-R SA Shingle Underlayment ASTM D1970 Drummondville, QC Gulfport, MS Wadsworth, OH self-adhering, glass-mat reinforced, sand- surfaced, SBS modified bitumen roof underlayment 4.15 PrimeSource Grip-Rite Eave & Valley Protector ASTM D1970 Drummondville, QC Gulfport, MS Wadsworth, OH self-adhering, glass-mat reinforced, sand- surfaced, SBS modified bitumen roof underlayment 4.16 SRS TopShield ICE & WATER DEFENDER ASTM D1970 Drummondville, QC Gulfport, MS Wadsworth, OH self-adhering, glass-mat reinforced, sand- surfaced, SBS modified bitumen roof underlayment 4.17 RESISTO LB1244 ASTM D1970 Drummondville, QC Gulfport, MS Wadsworth, OH self-adhering, glass-mat reinforced, sand- surfaced, SBS modified bitumen roof underlayment NEMO|etc. NEMO ETC, LLC Evaluation Report S18010.06.09-R20 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R22 (NON-HVHZ) Soprema Roof Underlayments Revision 20: 04/19/2021 Page 4 of 8 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS FBC Section: 1507.2 1507.3 1507.4 & 1507.5 1507.7 1507.8 & 1507.9 Underlayment Asphalt Shingles Clay and Concrete Tile Metal Slate or Slate-Type Shingles Wood Shakes or Shingles Mechanical Attach Adhesive- Set Panels Shingles LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment Yes Yes Yes See 5.6.1 Yes Yes Yes Yes (joint strips, 1507.1.1.3 / R905.1.1.3) LASTOBOND Shield, Pro HT-N, RESISTO SA SMOOTH PLY 40 Yes No No Yes Yes Yes Yes (joint strips, 1507.1.1.3 / R905.1.1.3) LASTOBOND Shield HT, Pro HT-S Yes No No Yes Yes Yes Yes (joint strips, 1507.1.1.3 / R905.1.1.3) EnviroShield Yes No No Yes Yes Yes Yes (joint strips, 1507.1.1.3 / R905.1.1.3) LASTOBOND ECO, RESISTO LB1236, TRI- BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER, RESISTO LB1244 Yes No No No No Yes Yes (joint strips, 1507.1.1.3 / R905.1.1.3) LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment, Grip-Rite Smooth Seal HT Yes No No Yes Yes Yes Yes (joint strips, 1507.1.1.3 / R905.1.1.3) 5.6.1 Adhesive-set tile is limited to use of the following Approved underlayment / tile-adhesive combinations. TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS1 Underlayment Adhesive Florida Product Approval LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment Dupont FL22525 ICP Adhesives and Sealants Polyset® AH-160 FL6332 1 e. NEMO|etc. NEMO ETC, LLC Evaluation Report S18010.06.09-R20 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R22 (NON-HVHZ) Soprema Roof Underlayments Revision 20: 04/19/2021 Page 5 of 8 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Substrates (designed to meet wind loads for project) Type Primer Material(s) LASTOBOND Shield, LASTOBOND Pro HT- N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, LASTOBOND ECO, RESISTO LB1236, TRI- BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER, RESISTO LB1244, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip-Rite Smooth Seal HT self- adhering Deck / sheathing (Optional) ASTM D41, Elastocol Stick, Elastocol Stick Zero plywood, OSB or Southern Yellow Pine (SYP) ASTM D41 structural concrete Insulation (Optional) Elastocol Stick Zero Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Base Sheet (Optional) Elastocol Stick Zero ASTM D226, Type II felt or Modified Sopra-G LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, RESISTO LB1236, TRI- BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self- adhering Existing substrate RESISTO EXTERIOR PRIMER Existing sand-surfaced, glass-fiber surfaced, mineral-surfaced or film- surfaced roof underlayment* * Final acceptance of any existing substrate in a reroof (tear-off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self-adhering underlayments, contact RESISTO technical support. 5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. 5.7.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON-TILE prepared roof coverings, attachment shall be in accordance with for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 instructions, but for mechanically attached base sheets - not less than Section 5.8.3 herein. 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual , Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct-to-Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual , Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. NEMO|etc. NEMO ETC, LLC Evaluation Report S18010.06.09-R20 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R22 (NON-HVHZ) Soprema Roof Underlayments Revision 20: 04/19/2021 Page 6 of 8 #1 Maximum Design Pressure = -45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self-adhered and back-nailed within the selvedge- 1- spaced 12-inch o.c.. #2 Maximum Design Pressure = -67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol Stick Zero Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self-adhered and back-nailed within the selvedge-- spaced 12-inch o.c.. #3 Maximum Design Pressure = -120.0 psf: Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) RESISTO EXTERIOR PRIMER Base Ply: RESISTO SA SMOOTH PLY 40, self-adhered. Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self-adhered and back-nailed within the selvedge-- spaced 12-inch o.c.. #4 Maximum Design Pressure = -150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self-adhered and back-nailed within the selvedge-- spaced 12-inch o.c.. #5 All other direct-deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of -45 psf. 5.8.3.2 Mechanically-Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual , Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist th e elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. #6 Maximum Design Pressure = -60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6- inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self-adhered and back-nailed within the selvedge-- spaced 12-inch o.c. 5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment attachment shall be and attachment of the insulation or coverboard shall be in accordance with Approval. NEMO|etc. NEMO ETC, LLC Evaluation Report S18010.06.09-R20 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R22 (NON-HVHZ) Soprema Roof Underlayments Revision 20: 04/19/2021 Page 7 of 8 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Installation Type Maximum Exposure (days) LASTOBOND Eco, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244 Mechanically attached 30 LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip-Rite Smooth Seal HT Mechanically attached 90 LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment Mechanically attached or adhesive-set tile roof system 180 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope LASTOBOND TU HT, Tri- Built S/A HT TU Underlayment Flat Max. 10-tile stack 6:12 Lugged Max. 10-tile stack 5:12 Lugged Double-tile stacking method, as shown below 6:12 6. INSTALLATION: 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.2.1 Installation of RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self-adhering underlayment in a reroof (tear-off) application atop an existing underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a reroof (tear-off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to th e suitability of an existing substrate to receive RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self-adhering underlayments, contact RESISTO technical support. NEMO|etc. NEMO ETC, LLC Evaluation Report S18010.06.09-R20 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R22 (NON-HVHZ) Soprema Roof Underlayments Revision 20: 04/19/2021 Page 8 of 8 6.3 LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND Eco, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment, Grip-Rite Smooth Seal HT, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244: 6.3.1 Non-Tile Applications: Shall be installed in compliance with requirements for an approved self-adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and . When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt the base shee t shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.3.2 Tile Applications: Limited to LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment. Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual , Sixth Edition and instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: UL, LLC QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT -