FL10626-R23
FL #
Application Type Revision
Code Version 2020
Application Status Pending FBC Approval
Comments
Archived
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parssppany, NJ D7054
(800)765-3411
mstieh9gaf.com
Authorized Signature Robert Niernmen
lreith@nemoetc.com
Technical Representative William Broussard
Address/phone/Email 1 Campus Drive
Parsippany, NJ D7054
(800) 766-3411
Tech nica IQu estionsGAF@gaf.com
Quality Assurance Representative
Address/phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License LLC66
UL
Quality Assurance Entity LC
Quality Assurance Contract Expiration Date 05/04/2023
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL1D626 R23 COI 2021 01 COI NIEMINEN. df
Year
standard
2015
ASTM D1970
201
ASTM D4533 (tear)
ASTM D4798(weathering)
2011
ASTM D4869 (water transmission)
2016
ASTM D5035 (tensile)
2011
201]
ASTM D6164
2016
ASTM D6757
2011
FM 4474
2018
FRSA/TRI, 6th Edition
FoilivalQnr,' of PrnriUrt Stanrlarria
Product Approval Method
Method 1 Option D
12/16/2021
Date Submitted 12/19/2021
Date Validated 12123/2021
Date Pending FBC Approval
# Model, Number or Name
10626A GAF Roof Underlayments for
use in FBC non-HVHZ
jurisdictions
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-442.5
Other: 1.) The design pressure noted in this
application relates to one particular
underlayment system. Refer to ER Section 5.8.3
for details. 2.) Refer to ER Section 5 for other
Limits of Use.
Description
Roofing Underlayments for use in sloped roof systems
Installation Instructions
FL 06 R2 II 021 12 14 FINAL ER GAF UNDER LAYMENTS FL1D626-
R23.p�f
Verified By: Robert Niemlen 59166
created by Independent Third Party: Yes
Evaluation Reports - , _ --., =a nac I mInFRLAYMENT5 FL1062E
by Independent Third Party: Yes
Contact Us :: 2681 Rlair Stone Roatl, T II h e FL 323ga Ph e' 850487-1824
privacy Statement ACCessIbIjMS atement :: Refund Statement
:: �_
The State of Florida Is an kvEEO employer. �opyy'" 2nnvv� -ntg State of Flanda.
Under Florida law, emall acddresses hare e public
m ofs, if you hone or b tr o tlonalelectronic
not amant il if you have anyprovide ra please cur .-Mail ddoess released 1, ons ct B5anlemal3 address It The95 -pursuantp have �ec-necords mduest, do not a4The ema8s
mall to this entity. Instead, y p y lease
effective October 1, 2012, licensees licensed under Chapter 455, a ersonai address, P
Florida Statutes, F.S., Please dick here .
provided may be used
for lea lema communication address wMChhcan be made availablertorthe public. �To determine if are aIf � licensee Chapte Y455,
provide the oeP produuR'AppreAfal AaeePt+°
C and
Safe
NEMO I etc.
certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06479
(203) 262-9245
ENGINEER EVALUATE
TEST CONSULT
Evaluation Report 01506.04.08-R23
GAF FL10626-R23
1Campus Drive Date of Issuance: 04/25/2008
Parsippany, NJ 07054 Revision 23: 12/14/2021
(800)766-3411
SCOPE: applicable rules and regulations governing the use of
This Evaluation Report is issued under Rule 61G20-3 and the
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product underthe Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 7tb Edition (2020) Florida Building Code sections noted
herein.
DESCRIPTION: GAF Roof Underlayments for use In FBC non-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507A.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the reference
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Evaluated" may be displayed
in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8
Prepared by:
The facsimile seal appearing was authorized by Robert
Robert J.M. Nieminen, P.E.
TJ
'•-: a -"=: a ' .��
,�Eyw.._..•E+.�F Nleminen,P.E. on 12/14I1011. This does not serve as an
59166, Florida DCAANE1983
`.;�; ;�;;.��" electronirallysigned document.
Florida Registration Na.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC Is not owned, operated or controlled by any company manufacturing or distributing products it distributing
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
financial interest in any other entity involved in the approval process o the
4. Robert Nieminen, P.E. does not have, nor will acquire, a
product. the D-signer of Record for any
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way,
project on which this Evaluation Report, or previous versions thereof, Is/was used for permitting or design guidance unless retained
specifically for that purpose. 02019 NEMO Err, LLC
MEMO I etc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
as produced by GAF, have demonstrated compliance with the
compliance Statement: GAF Roof Underlayments,
a Building Code through testing in accordance with the following
following sections of the 7"Edition (2020) Florid
n Requirements and Limitations /Conditions of Use set forth
Standards. Compliance is subject to the Installatio
herein.
Section
1504.3.1
1507.1.1, 1507.2.4, 1507.2.9.2 / R905.1.1,
R905.2.8.2
1507.1.1.1(2&3, Exception), 1507.1.1.1(5) /
R905.1.1.1(2&3, Exception), R905.1.1.1(5)
1507.1.1.1(2&3, Exception), 1507.1.1.1(5) /
R905.1.1.1(2&3, Exception), R905.1.1.1(5)
1507.1.1.1(5) / R905.1.1.1(5)
1507.1.1 / R905.1.1
1507.3.3, R905.3.3
1507.11.2
TAS 110
Property
Wind resistance
Material standard
Tear Strength
Tensile strength
Liquid water transmission
Material standard
Material standard
Material standard
Accelerated Weathering
Standard
Year
FM 4474
2011
ASTM D1970
2015
ASTM D4533
2015
ASTM D5035
2011
ASTM D4869
2016
ASTM D6757
2016
FRSA/TRI, Sixth Edition
2018
ASTM D6164
2011
ASTM D4798
2011
---�- FL1D626-1123
NEMO ETC, LLC 7TM EDITION (2020) FBC NON-HVHZ EVALUATION
,[ o)Autw00Hon 932E55 Revision 23: ]2/14/2o
Ce,ff9
GAF Roof UndeAayments page T of
4.1
4.2
4.3
4.4
4.5
M.
EntlW
UL, LUC
UL, LLC
Examination
Product
GAF Extended Dry -In Membrane
Liberty- SBS Self -Adhering Base/Ply
Sheet
StormGuard• HIM -Surfaced Leak Barrier
WeatherWatcho Mineral -Surfaced Leak
Barrier
Deck -Armor'" Premium Breathable Roof
Deck Protection
FeltBuster° Synthetic Roofing Felt
4.7 Shingle -Mate° Roof Deck Protection
4.8 StormSafe' Anchor Sheet
Tiger Paw- Premium Roof Deck
4-9 Protection
VersaShield° Fire -Resistant Roof Deck
4.10 Protection
4.11 1 Ruberoid° Mop Granule
4.12 I Ruberoid° Mop Granule FR
Reference
Material Standard
ASTM D1970
ASTM D1970
ASTM D1970 (Table 1)1
ASTM D1970
1507.1.1.1(2&3, Exception) /
R905.1.1.1(2&3, Exception)
1507.1.1.1(2&3, Exception),
1507.1.1.1(5) / R905.1.1.1(2&3,
Exception), R905.1.1.1(5)
ASTM D226, Type II (Table 11
1507-1.1.1(2&3, Exception) /
R905.1.1.1(2&3, Exception)
1507.1.1.1(2&3, Exception) /
R905.1.1.1(2&3, Exception)
ASTM 0226, Type II
ASTM D6164
FRSA/TRI D9-18
ASTM D6164
FRSA(TRI 09-18
ONEMOletc.
Date
Plartt(s)
Langley, BC Canada
Mt. Vernon, IN
Savannah, GA
Mt. Vernon, IN
Savannah, GA
Dadra, India
Dadra, India
Gujarat, India
(CPP) Rajasthan, India
(MIP) Rajasthan, India
Richmond, VA
Sparta_ burg, urg, SC
Pryor, OK
North Bay, ON
Dadra, India
Gujarat, India
Parzai, India
Conover, NC
Savannah, GA
Savannah, GA
have a lesser coefficient of friction than ASTM
StormGuarde Film -Surfaced Leak Barrier has been found through cnmparctive testing to
as forth in Section 4.3, Note
0226 roofing felt when tested at standard laboratory conditions. Agreement between purchaser and seller,
1 of ASTM D1970-I5, should be established as to slip resistance. Evaluation Report 01506.04.G&R23
NEMO ETC, LLC FL30626-R23
CcrtMrm °fA°rhodmti°n N32a55 7P1EDITION 120201 FBC NON-HVH2 EVALUATION Revision 23:12/14/2021
GAF Roof Undedayments page 3 of 8
ONEMOletc.
bert Nle
ithLLC nor Ro
P.E. are, in anyway, the Designer
5.1 This is a building code evaluation. Neer NEMO ETC, sions t
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miaml-
Dade Counties).
of components. Authority
decks and structural members shall be in
53 This Evaluation Report pertains to above -deck ron of the Authority
accordance with FBC requirements to the satisfactioHaving Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
y be
de to the Authority
within
oval based on this evaluation combined with supporting tdata for th a prepared roof covering.iHaving Jurisdiction for
ng.
approval
5.6 Allowable_ Rooms
TABLE 1: ROOF COVER OPTIONS
1507.3 1507.4 and 1507.5 ]507.7 3507.8 too 3507.9
FBC Section: 3507.1 Wood
Clay and concrete Tile Metal Slate or
Asphalt slate -Type Shingles Shakes
Shingles Underlayment Mechanical Adhesive- panels Shingles Shingles
Attach Set Yes
Yes
No
No
Yes
Yes
Yes
131n.1.13/
iW.1.13/
GAF Extended Dry -In Membrane
Yes
Rsos.12.3)
a9A5.12.31
Yes
Yes
No
No
No
No
bavntlnlw'
tsm.LL3/
Bplirt snip..
1902113/
Liberty'"SBS Self -Adhering
Yes
No
Rsos.l.l.$)
asost.us)
Base/Ply Sheet
Yes
Yes
Leak
No
No
Yes
Yes
Yes
Uolnt snips.
fsm.1.13/
Uolnt rtdps,
lsm.l.l3!
StormGuard•film-Surfaced
Yes
RB5.1.1.31
a9ps.tasl
Baffler
Yes
Yes
No
No
Na
No
No
Ilpint snips.
tsm.1.31
Urine svlPs.
tsm.lxa/
WeatherWatch• Mineml-Surfaced
Yes
R90SAA31
R9 stt.31
Leak Baffler
No
No
Deck -Armor"' Premium Breathable
Yes
No
No
Yes
Yes
Yes
Roof Deck Protection
No
No
No
No
No
No
FeltBuster"SYnthetic Roofing Felt
Yes
No
No
No
No
Shingle -Mate• Roof Deck
Yes
No
No
No
No
Protection
Yes
Yes
Yes
No
No
Tiger Paw'" Premium Roof Deck
Yes
No
No
Protection
No
No
No
No
No
VersaShield• Flre-Resistant Root
Yes
No
No
Deck Protection
Yes
Yes
(Cap Sheet In
No
No
No
No
No
Ruberoid• Mop Granule
No
Ica, 5heet'm
2-ply systeml
2-plysysteml
See 5.6.3
Yes
Yes
(cap Sheet in
No
No
No
No
No
ROberofd•MOp Granule FR
No
(cap Sheet in
2-plysysteml
2"IY system)
q.e 5.6.1
Evaluation Report 01SO624.08-R23
FL10626-R23
NEMO ETC, LLC 7-EDITION (2020) FBC NON-HVHZ EVALUATION
ipmre of Authorirution #32455 Revision 23: 1Page 4 of 3
Cert
GAF Roof Underlayments page 4 of
ONEMOletc.
5.6.1 Adhesive -set is limited to use of following underlayment / tile -adhesive combinations.
TABLE M ALLOWABLE UNDERIAYMENT f TILE -ADHESIVE COMBINATION52
Adhesive Florida Product Approval
Underlayment FL22525
Ruberold Mop Granule Ruberold Mop Granule FR Dupont Tile Bond Roaf 1 -Adhesive
5.7 Allowable Substrates:
GAF Extended Dry -In Membrane
i Iherty- sB5 Self -Adhering Base
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENFS
Sheet
Sto,Guard° Film -Surfaced Leak Barrier
Weather Watch° Mineral -Surfaced Leak Barrier
Liberty- SBS Self -Adhering Base/Ply Sheet
StormGuard° Film -Surfaced Leak Barrier
Weather Watch' Mineral -Surfaced Leak Barrier
Uberty' SBS self -Adhering Base/Ply Sheet
StormGuard° Film -Surfaced Leak Barrier
Weather Watch• Mineral -surfaced Leak Barrier
Application primer
self -adhering None plywood
(Optional) plywood
self -adhering ASTM D41
self -adhering � None
self -adhering � ASTM D41
Substrates
ASTM D226 felt, Type 11
metal (flashing metal, valley metal,
etc.)
ist
nulenule FRanuleanule FR
5.8 Attachment Limitations: accordance LE
5.8.1 the manufacturer's mechanically
installation instructions,lbu prepared
r for mechanically attach daunderlaymchment ents or base sheets nlot
less than FBC 1507.1.1 or R905.1.1.
5 8 2 For use uner s but it fo methane ally attached se attachment
allbsheets I not lecos than: with the manufacturer's installation
Instruction
FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1(for Two -Ply Asphalt Applied Hot Mop Underlayment)
or
° Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment systeM in
to underlayment that are not prescriptive in the FRSA/TRI
The following wind uplift limitations apply
Florida High Wind Concrete and Cloy Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testingfor wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Dlrect-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA RI
Florida High Wind concrete and Clay Roof rile installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
2 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment
Resistance erf orMunce.
Evaluation Report
NEMO ETC, LLL FL10626-RZ3
NEIV Gate C, LLC woarion t32ASS 7^ EDITION J20201 F9c NON.HVHZ EVALUATION Revision 23: 12/1412021
GAF Roof Underlayments page 5 of 9
ONEIVIOletc.
#1 Maximum Design Pressure=-442.5 psf.
Deck: Min. press psi structural concrete to meet project requirementsto satisfaction of Authority Having
Jurisdiction 5 Base
Rase Sheet: Base Sheet, Tri-Ply #7
Tri P V Ply#4 or GAFGLAS Flex Ply 6 applied infullmopping oeet, GAFGLAS fASTMBO ID312, Type IV hot aspma Base Sheet, halt at 20
to 25lbs/square.
ids Mop Granule FR applied in full mopping of ASTM D3 Type
Cap Sheet: Ruberoid® Mop Granule or Rubero
IV hot asphalt at 20 to 25 Ibs/square.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA(TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 2609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC1609orFBCResidential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application standard RAS 117. Assemblies marked with an asterisk" carry the limitations set forth in Section
2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements.
#2 Maximum Design Pressure=-45 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
eet D.C.
r Ruberoid° 20 smooth mechanically attached with
Base Sheet: GAFGLAS° #80 Ultima' Base Sh
min.1.25-Inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch D.C.
at the min. 4-inch wide side laps and 9-inch D.C. at two (2), equally spaced, staggered center rows
in the field of the sheet.
Cap Sheet: Ruberoid° Mop Granule or Rube
Map Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
#3 Maximum Design Pressure=-75 psf.
Deck: Min. 19/32-inch plywood 10 meet project requirements to satisfaction of Authority Having
Jurisdiction.
Sheet or Ruberoid° 20 Smooth mechanically attached with 1 ga.,
Base Sheet: GAFGLAS° #80 UltimaT" Base
min.1.25-inch long ring shank nails through 32 ga., 1-5/8-incdiameter
tin caps
spacedgered c8-in chows
at the min. 4-Inch wide side laps and 8-inch D.C. at three (3), equally sP
in the field of the sheet.
Cap Sheet: Ruberold°MopGranuleorRuberoid°Mop Granule FRapplied infull mopping ofASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
#4 Maximum Design Pressure=-97.5psf.
d to meet project requirements to satisfaction of Authority Having
Deck: Min. 19/32-inch plywoo
Jurisdiction.
Sheet or Ruberoid° 20 Smooth mechanically attached with 1 ga.,
Base Sheet: GAFGLAS° #80 Ultima' Basemin. 1.25-inch long ring shank nails through 32 ga., 1-5/8-Inch diameter tin caps spaced 4-inch D.C.oC
at the min. 2-inch wide side laps and 44nch D.C. at four (4), equally spaced center rows in the field
of the sheet. ° lied in full mopping of ASTM D312, Type
Cap Sheet: Ruberoid° Mop Granule or Ruberoid Mop Granule FR applied
IV hot asphalt at 20 to 25 Ibs/square.
Evaluation Report 01506'04.08-R23
FL10626-R23
NEMO ETC, LLC 7TH EDITION (20201 FBC NON-HVHZ EVALUATION
ijlmte fA.thorilutina 032455 oRevision 23: 1Page 6 of 9
Cert
GAF Roof Underlayments page 6 of 8
5.9 Exposure Limitations:
Underlayment
TABLE 3: EXPOSURE LIMITATIONS
Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster• Synthetic
Roofing Felt, Shingle -Mate` Roof Deck Protection, StormSafe - Anchor Sheet, Tiger
Paw'" Premium Roof Deck Protection, Versashieldo Fire -Resistant Roof Deck
Protection, Liberty"' SBS Self -Adhering Base/Ply Sheet, StormGuard• Film -Surfaced
Leak Barrier and WeatherWatch• Mineral -Surfaced Leak Barrier
GAF Extended Dry4n Membrane
Ruberoid• Mop Granule and Ruberoid• Mop Granule FR
ON EMID I etc.
Maximum
Prepared Roof Cover Exposure
Installation Type Idays)
Mechanically attached I 30
Mechanically attached 180
Adhesive -set the roof system 180
Mechanically attached UNLIMITED
in direct -deck the roof assemblies, the
5.10 Tile Sliooaee Limitations: When loading roof tiles on the underlayment
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
Ns
TABLE 4- TILE SUPPAGE UMITATIONS FOR DIRECT-DEcx TILE INSTAL1ATIO
The Profile staging Method
Maximum Stag
Underlaymem
Max. 10-tile stack
4:12
Flat
Max. 6-tile stack (4 over 2)
5:12
Ruberold• Mop Granule
Flat
Max. 10-tile stack
5:12
Lugged
Max. 6-tile slack (4 over 2)
5:12
Ruberoid• Mop Granule FR
Flat or Lugged
Lugged Max. 10-tile stack
4:12
6-1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. sweep the substrate thoroughly to
remove any dust and debris prior to application and prime the substrate (if applicable).
6.3 Deck-Armorm Premium Breathable Roof Deck Protection or Tiger Paw' Premium Roof Deck Protection:
6.3.1 Shall be installed in Compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception)
R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type
or 1507.1.1.1(3, Exception) or FBC Residential
of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation Instructions.
6.4 FeltBuster- Synthetic Roofing Felt:15
6.4.1 Shall be installed in compliance with requirements far a synthetic underlayment p FBC R905 1.1.1(3, Exception)
1507.1.1.1(3, Exception) or 107.1.1.1(a5edr FBC roof Rover covering to beinstalled, and Phenmlanufacturer's installation
in Ructions.1(5) for the typeprepared
instructions. FBC requirements take precedence over the manufacturer's installation instructions.
6.S StormSafe- Anchor sheet:
6.5.1 StormSafe'" Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems.
6-5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception)
or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type
C requirements
of prepared roof coveringto be installed, and the manufacturer's installation Instructions. FB
precedence over the manufacturer's installation Instructions.
Evaluation Report 01S06.04.08-R23
, FL30626-R23
NEMO ETCLLC EMOme CLC r6atlw, x32455 7TM EDITION(20201 FBC NON-HVHZ EVALUATION Revision23:12/14/21121
GAF Roof Underlayments Page 7 of 8
ONEMOletc.
6.5.3 One the same day, install Liberty'' SBS Self -Adhering Base/Ply; StormGuard° Film -Surfaced Leak Barrier or
WeatherWatch° Mineral -Surfaced Leak Barrier over the StormSafe" Anchor Sheet.
6.6 Shingle -Mate° Roof Deck Protection:
6.6.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM
0226, Type 11) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
6.7 VersaShield° FireResistant Roof Deck Protection
6.7.1 Shall be installed incompliance with requirements for an approved mechanically attached underlayment (ASTM
D6757) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be
installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
6.8 GAF Extended Dry -In Membrane, Liberty'" SBS Self -Adhering Base/Ply Sheet, StormGuard° Film -Surfaced Leak
Barrier or WeatherWatch° Mineral -Surfaced Leak Barrier:
6.6.1 Shall be installed in compliance with requirements for an approved self adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.2.1.3 or FBC Residential R9o5.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation Instructions.
6.B.2 Back -nailing is required. Back -nailing shall consist of Approved cap nails spaced 18-Inch o.c., encapsulated within
min. 4-inch side laps.
BC Approved ASTM D226 Type II felt, the felt shall be fastened in
6.8.3 When installed over a mechanically attached, F
accordance with FBC 1507.1.1 or R905.1.1.
5.8.4 GAF Extended Dry -In Membrane, Liberty'" SBS Self -Adhering Base/Ply Sheet, StormGuard° Film -Surfaced Leak
Barrier or WeatherWatch° Mineral -Surfaced Leak Barrier may be installed as a secondary water barrier using
minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system.
6.9 Ruberoid° Mop Granule Ruberold Mop Granule FR.
Sheet" in the
6.9.1 Shall be installed in compliance with s as an alternateto Wind Concrete andhClay Roof Tiletinstalllatied onpManual, S xth
'Two ply System' in the FRSA/TI Florida High
Edition, and the manufacturer's installation instructions.
6.9.2 Refer to Section 5.8 herein for attachment limitations.
6.9.3 Refer to Table 4 for tile staging limitations.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the named CA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
UL, LLC.—QUA9625; (613) 371-2765; Jacob Stewartul.com
- END OF EVALUATION REPORT -
Evaluation Report 01506.04.08-R23
NENIO ETC, LLC FL10626-R23
Ceelfimte afA"Mwtratian p32455 T" EDITION (2020) FBC NON-HVH2 EVALUATION Revision 23; 12/14/2021
GAF Roof Underlayments Page a of 9