HomeMy WebLinkAboutEnergy Efficiency Codet
FORM R405-2020
RECE1VEp
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING �.QNSfI ICTION
t!1/t mg De
Florida Department of Business and Professional Regulation - Residential PeitdpWc- ftmethod
Project Name: Lot 66 Block 1 Waterstone 1780 AGR Builder Name: ADAMS HOMES
Street: 8601 Merano Avenue Permit Office:
City, State, Zip: Fort Pierce , FL, 34951 Permit Number:
Owner: Jurisdiction: 661000
Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 )
I. New construction or existing
New (From Plans)
10. Wall Type>;1513.4 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1245.40 ft2
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0 268.00 ft2
4. Number of Bedrooms
3
c. N/A
d . N/A
R= ft2
5. Is this a worst case?
No
11. Ceiling Types (1900.0 sgft.)
R- ft2
Insulation Area
6. Conditioned floor area above grade (ft2)
1780
a. Under Attic (Vented)
b. Knee Wall (Vented)
R=30.0 1780.00 ft2
R=19.0
Conditioned floor area below grade (ft2)
0
c. N/A
120.00 ft2
R= ft2
7. Windows(177.0 sqft.) Description
Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33
113.31 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 356
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
45.94 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55
17.78 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 2.639 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.272
a. Electric Heat Pump
28.2 HSPF:8.50
8. Skylights
Area
c. U-Factor:(AVG) N/A
ft2
SHGC(AVG): N/A
15. Hot water systems
9. Floor Types (1780.0 sqft.)
Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 1780.00 ft2
b. Conservation features
EF: 0.940
b. N/A
R= ft2
None
c. N/A
R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.099
Total Proposed Modified Loads: 52.71
Total
PASS
Baseline Loads:
52.75
I hereby certify that the plans, ications covered
this calculation are in comp' h the Flod E�t�Pgj
Code. �' �''
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida n-
OWNER/AGENT),
DATE:
R"w of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.'
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
., - %-1111uanae requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
y envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.055 Qn for whole house.
6/7/2021 11:38 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2171211 IAIDI IT C1I11A11AADU ruci+u. cr
PROJECT
Title:
Lot 66 Block 1 Waterstone 17 Bedrooms: 3
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 1780
Lot #
66-1
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
8601 Merano Avenue
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce
Family Type:
Detached
,
New/Existing:
New (From Plans)
FL, 34951
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating Design Daily Temp
V Design
Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days
Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1780 15664
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1780 15664 Yes 4
3 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 155.7 ft 0
1780 ft2 ----
0.38 0 0.62
ROOF
/
V
Roof Gable Roof
Red Solar SA Emitt
Emitt Deck Pitch
#
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 1990 ft2 446 ft2 Medium
N 0.85 N 0.85
No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1780 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Knee Wall (Vented)
Main 19 Batt
120 ft2 0.11
Wood
2
Under Attic (Vented)
Main 30 Blown
1780 ft2 0.11
Wood
6/7/2021 11:38 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 IAIDI IT CI MAUAMy r►u�i+v. -.�
WALLS
Adjacent
Space
CaWidth
R_Vvitqlly
Height
Sheathing Framing Solar Below
1 S Exterior Concrete Block - Int Insul
Main
4.1 40 0
8 0
320.0 ft2
0
0 0.6
2 W Exterior Concrete Block - Int Insul
Main
4.1 40 6
8 0
324.0 ft2
0
0 0.6
0
3 NW Exterior Concrete Block - Int Insul
Main
4.1 3 0
9 6
28.5 ft2
0
0 0.6
0
4 N Exterior Concrete Block - Int Insul
Main
4.1 11 10
9 6
112.4 W
0
0 0.6
0
0
5 NE Exterior Concrete Block - Int Insul
Main
4.1 3 0
9 6
28.5 ft2
0
0
6 E Exterior Concrete Block - Int Insul
Main
4.1 54 0
8 0
432.0 ft2
0
0.6
0 0.6
0
7 - Garage Frame - Wood
Main
13 33 6
8 0 .
268.0 ft2
0
0.23 0.01
0
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1 N Insulated Main
None
.25
3
6 8
20 ft2
2 - Wood Main
None
.46
2
8
6 8 17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed
orientation.
/ Wall
Overhang
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1 S 1 Metal Low-E Double
Yes
0.55 0.7 N
17.8 ft2
14 ft 4 in
0 ft 10 in
None
None
2 S 1 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
3 W 2 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
4 NW 3 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
5 N 4 Vinyl Low-E Double
Yes
0.33 0.21 N
23.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
6 NE 5 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
7 E 6 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 591 ft2 591 ft2
64 ft
8 ft
1
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000391
1827.5 100.26 188.23
.1312
7
HEATING SYSTEM
# System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
Sing] HSPF:8.5
28.2 kBtu/hr
1
sys#1
6/7/2021 11:38 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORUM R405-2020 INPUT SIIMMARV rI41=r1q IQT D=DnoT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 28.4 kBtu/hr cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftz
DUCTS
/ ---- Supply ----
---- Return --- Air
CFM 25
CFM25
HVAC #
�/ # Location R-Value Area
Location
Area Leakage Type Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 356 ft2
Main
89 ftZ Proposed Qn Main
--- cfm
97.9 cfm 0.06 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan eb
Heating Jan HF
Feb
Venting
Mar
Mar
H
A r
Apr
u
May Jun Jul u
Ma rl
Jun X Jul Mug
Se
Sep
ri
f
Oct
Oct
HNOV
Nov
Dec
HDec
Jan Feb
Mar
[X]
Apr [
May JunJul
Se
[
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6 7
8
9
10
11
12
Cooling (WD) AM
PM
78
80
78
80
78
78 78 78 78
78
80
80
80
80
78
78 78 78 78
78
78
78
78
78
Cooling (WEH) AM
PM
78
78
78
78
78
78 78 78 78
78
78
78
78
78
78
78 78 78 78
78
78
78
78
78
Heating (WD) AM
PM
66
68
66
68
66
68
66 66 68 68
68
68
68
68
68
68 68 68 68
68
68
68
66
66
Heating (WEH) AM
PM
66
68
66
68
66
66 66 68 68
68
68
68
68
68
68
68 68 68 68
68
68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ftz
0 ft 0.3
6/7/2021 11:38 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
8601 Merano Avenue,
Fort Pierce, FL, 34951
- 1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1245.40 ft2
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0
268.00 ft2
c. N/A
R=
ft2
4. Number of Bedrooms
3
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
6. Conditioned floor area (W)
1780
a. Under Attic (Vented)
b. Knee Wall (Vented)
R=30.0
R=19.0
1780.00 ft2
120.00 ft2
7. Windows- Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
113.31 ft2
12. Ducts, location & insulation level
R ft2
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 356
b. U-Factor: Dbl, U=0.33
45.94 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
17.78 ft2
a. Central Unit
28.4 SEER:15.00
SHGC: SHGC=0.70
d. U-Factor: N/A
ft2
SHGC:
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
2.639 ft.
a. Electric Heat Pump
28.2
HSPF:8.50
Area Weighted Average SHGC:
0.272
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
9. Floor Types
Insulation Area
b. Conservation features
a. Slab -On -Grade Edge Insulation
R=0.0 1780.00 ft2
None
b. N/A
R= ft2
Credits (Performance method)
Pstat
c. N/A
R= ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature Date:
Address of New Home:
City/FL Zip:
y *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/7/2021 11:39 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1