Loading...
HomeMy WebLinkAboutEnergy Efficiency Codet FORM R405-2020 RECE1VEp FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING �.QNSfI ICTION t!1/t mg De Florida Department of Business and Professional Regulation - Residential PeitdpWc- ftmethod Project Name: Lot 66 Block 1 Waterstone 1780 AGR Builder Name: ADAMS HOMES Street: 8601 Merano Avenue Permit Office: City, State, Zip: Fort Pierce , FL, 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) I. New construction or existing New (From Plans) 10. Wall Type>;1513.4 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1245.40 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 268.00 ft2 4. Number of Bedrooms 3 c. N/A d . N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1900.0 sgft.) R- ft2 Insulation Area 6. Conditioned floor area above grade (ft2) 1780 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 1780.00 ft2 R=19.0 Conditioned floor area below grade (ft2) 0 c. N/A 120.00 ft2 R= ft2 7. Windows(177.0 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 113.31 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 356 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 45.94 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 2.639 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.272 a. Electric Heat Pump 28.2 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 SHGC(AVG): N/A 15. Hot water systems 9. Floor Types (1780.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.099 Total Proposed Modified Loads: 52.71 Total PASS Baseline Loads: 52.75 I hereby certify that the plans, ications covered this calculation are in comp' h the Flod E�t�Pgj Code. �' �'' PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida n- OWNER/AGENT), DATE: R"w of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code.' Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: ., - %-1111uanae requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an y envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.055 Qn for whole house. 6/7/2021 11:38 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2171211 IAIDI IT C1I11A11AADU ruci+u. cr PROJECT Title: Lot 66 Block 1 Waterstone 17 Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 1780 Lot # 66-1 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 8601 Merano Avenue Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce Family Type: Detached , New/Existing: New (From Plans) FL, 34951 Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1780 15664 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1780 15664 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 155.7 ft 0 1780 ft2 ---- 0.38 0 0.62 ROOF / V Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1990 ft2 446 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1780 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Knee Wall (Vented) Main 19 Batt 120 ft2 0.11 Wood 2 Under Attic (Vented) Main 30 Blown 1780 ft2 0.11 Wood 6/7/2021 11:38 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 IAIDI IT CI MAUAMy r►u�i+v. -.� WALLS Adjacent Space CaWidth R_Vvitqlly Height Sheathing Framing Solar Below 1 S Exterior Concrete Block - Int Insul Main 4.1 40 0 8 0 320.0 ft2 0 0 0.6 2 W Exterior Concrete Block - Int Insul Main 4.1 40 6 8 0 324.0 ft2 0 0 0.6 0 3 NW Exterior Concrete Block - Int Insul Main 4.1 3 0 9 6 28.5 ft2 0 0 0.6 0 4 N Exterior Concrete Block - Int Insul Main 4.1 11 10 9 6 112.4 W 0 0 0.6 0 0 5 NE Exterior Concrete Block - Int Insul Main 4.1 3 0 9 6 28.5 ft2 0 0 6 E Exterior Concrete Block - Int Insul Main 4.1 54 0 8 0 432.0 ft2 0 0.6 0 0.6 0 7 - Garage Frame - Wood Main 13 33 6 8 0 . 268.0 ft2 0 0.23 0.01 0 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Metal Low-E Double Yes 0.55 0.7 N 17.8 ft2 14 ft 4 in 0 ft 10 in None None 2 S 1 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 3 W 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 4 NW 3 Vinyl Low-E Double Yes 0.33 0.21 N 11.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 5 N 4 Vinyl Low-E Double Yes 0.33 0.21 N 23.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 6 NE 5 Vinyl Low-E Double Yes 0.33 0.21 N 11.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 7 E 6 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 591 ft2 591 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000391 1827.5 100.26 188.23 .1312 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Sing] HSPF:8.5 28.2 kBtu/hr 1 sys#1 6/7/2021 11:38 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORUM R405-2020 INPUT SIIMMARV rI41=r1q IQT D=DnoT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 28.4 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS / ---- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 356 ft2 Main 89 ftZ Proposed Qn Main --- cfm 97.9 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan eb Heating Jan HF Feb Venting Mar Mar H A r Apr u May Jun Jul u Ma rl Jun X Jul Mug Se Sep ri f Oct Oct HNOV Nov Dec HDec Jan Feb Mar [X] Apr [ May JunJul Se [ Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 6/7/2021 11:38 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 8601 Merano Avenue, Fort Pierce, FL, 34951 - 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1245.40 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 268.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area 6. Conditioned floor area (W) 1780 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 R=19.0 1780.00 ft2 120.00 ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.33 113.31 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.23 a. Sup: Attic, Ret: Main, AH: Main 6 356 b. U-Factor: Dbl, U=0.33 45.94 ft2 SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 17.78 ft2 a. Central Unit 28.4 SEER:15.00 SHGC: SHGC=0.70 d. U-Factor: N/A ft2 SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.639 ft. a. Electric Heat Pump 28.2 HSPF:8.50 Area Weighted Average SHGC: 0.272 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.94 9. Floor Types Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ft2 None b. N/A R= ft2 Credits (Performance method) Pstat c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature Date: Address of New Home: City/FL Zip: y *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/7/2021 11:39 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1