HomeMy WebLinkAboutTruss (2)w
r
w�
258 Southhall Lane, Suite 200
fiF; �D Maitland, Florida 32751
P: (321) 972-0491 1 F: (407) 880-2304 1 E: info@fdseng.com
vS1 Website: www.fdseng.com
ENGINEERING ASSOCIATES
July 19, 2021
Building Department
Ref:
Adams Homes
Lot:
Lot 66 Blk.1
Subdivision:
Fort Pierce - Waterstone
Address:
8601 Merano Ave.
Model:
1780 3CF A RHG
KA #
21-8328
Truss Company:
Builders First Source
Date of drawings:
7/6/21
Job No.:
2813124
Wind Speed:
160
Exposure:
C
Truss Engineer:
Joaquin Velez
To whom it may concern,
RECEIVED
AUG 0 3 702,
Perrnittin9 Depart
St. Lucie Countyent
We have reviewed the truss design package for the project referenced above. This truss package
complies with the original design intent and the underlying structure will accommodate all
indicated loads. We approve the truss package without comment based upon the truss layout and
truss profiles supplied to us by the Truss Company with truss profiles sealed by the Truss
Engineer.
Please note, this review is only for general conformance with the design concept of the project.
Contractor or sub -contractor is responsible for matching all structural components and details
shown in the construction documents. Contractor or sub -contractor is also responsible for
confirming all quantities and dimensions; selecting appropriate fabrication processes anq.111I I i q r,11,
techniques; and coordinating work with all other trades. ,•a p ABLO
�`d�\�•�-�C ENS �`4�',
Note: Truss ID's may vary. ?� . • N0 878 4 • ��`� s®
d
If you have any questions, please do not hesitate to call. y� •; ,
Sincerely, fl�• TA OF
Ile
S RIONA L
P•'�;�
IfiIIIII,aai
7/19/2021 7/19/2021 7/19/2021
Carl A. Brown, P.E. Scott Lewkowski, P.E. Luis Pablo orres, P.E.
FL. # 56126 FL. #78750 FL. # 87864
FDS Engineering Associates, A TSG Company
"Your Building Code Experts"
J
CONNECTORS SCHEDULE
ROOF TRUSS
Q
ID
MODEL ROOF UPLIF7T SYM
0
P11
LUS24 / JUS24
895 / 835
14901510
1LI
7
A
11 HTU26/ THD26
3600 / 3470
1155512330
11
0
B
11 HTU28 / THD28
4680 / 5040
1214012330
1LB
0
C
HTU26-2 / THD26-2
3600 / 3356
2175 / 2340
1 Lc
0
D
HTU28-2 / THD28-2
4680 / 5005
3485 / 2595
1 to
0
E
HGUS26-2 / THDH26-2
5320 / 5245
2165 / 2340
1 1
0
F
HGUS28-2 / THDH28-2
7460 / 8025
3235 13330
11F
0
G
HGUS26-3 / THDH26-3
5230 / 5245
2155 / 2340
1 tc
0
H
HGUS28-3 / THDH28-3
7460 / 7836
3235 / 4370
1 w
0
J
THJA26 / HJC26
9100 / 8990
4095 / 4370
1 W
3X8NOP
O Reviewed and Approved ❑ Revise and Resubmit
❑ Reviewed with Notations ❑ Not Reviewed (see explanation)
Corrections or comments made on equipment submittals or shop drawings during this review do
not relieve contractor from compliance with requirements of the drawings and specifications.
This check is only for review of general conformance with the concept of the project and
general compliance with the information given in the contract documents. The contractor is
responsible for confirming and correlating all quantities and dimensions; selecting fabrication
processes and techniques of construction; coordinating his work with that of all other trades and
performing his work in a safe and satisfactory manner
FDS ENGINEERING ASSOCIATES
Date: 07/19/2021 BT ES
Submittal No.: Project No.: 21-8328 Project Eng.: Luis Torres
Project Name: Adams Homes - Fort Pierce - Waterston - Lot 66 Blk 1 /
VERIFY ALL DMENSIONS AND HUNG CONDITIONS PPoOR TO APPROJAL
SOME CEIUNG FRAMING REOURED N RELD BY BUILDER
MAN W1 D FORCE RESISTWG SYSTEMIC4 HYBPoD WIND MCU46
ENCLOSED
EXPOSURE CATEGORY c
OCCUPANCY CATEGORY
WIFID LOAD 160 MPH
WND n1PORTANCE FACTOR 1.00
TRUSSES HAVE BEEN DES13NED FOR A 10.0 PSF BOTTOM CHORD LIVE LOAD
NONCONCURRENT WRH ANY OTHER LIVE LOADS
ROOF LOADING FLOOR LOADING
TCLL: 20 PSF TCLL: 40 PSF
TCDL: 07 PSF TCDL: 10 PSF
BCDL: 10 PSF BCDL: 5 PSF
TOTAL: 37 PSF TOTAL: 55 PSF
DURATION: 1.25 DURATION: 1.00
IMPORTANT
This Drawing Must Be Approved And
Returned Before Fabrication Will
Begin. For Your Protection Check All
Dimensions And Conditions Prior To
Approval Of Plan.
SIGNATURE BELOW INDICATES ALL
NOTES AND DIMENSIONS HAVE
BEEN ACCEPTED.
By Date
CAUTION!!!
DO NOT ATTEMPT TO ERECT
TRUSSES WITHOUT REFERRING TO
THE ENGINEERING DRAWINGS AND
BSC1431 SUMMARY SHEETS.
ALL PERMANENT BRACING MUST BE
IN PLACE PRIOR TO LOADING
TRUSSES. (le. SHEATHING,
SHINGLES, ETC.)
ALL INTERIOR BEARING WALLS
MUST BE IN PLACE PRIOR TO
INSTALLING TRUSSES.
REFER TO FINAL ENGINEERING
SHEETS FOR THE FOLLOWING.
1) NUMBER OF GIRDER PLIES AND
NAILING SCHEDULE.
2) BEARING BLOCK REQUIREMENTS.
3) SCAB DETAILS (IF REQUIRED)
4) UPLIFT AND GRAVITY REACTIONS.
WARNING
Backeharges Will Not Be Accepted
Regardless of Fault Without Prior
Notification By Customer Within 48
Hours And Investigation By
Builders First Source.
NO EXECPTIONS.
The General Contractor Is Responsible
For All Connections Other Than Truss
to Truss, Gable Shear Wall, And
Connections. Temporary and
Permanent Bracing, And Ceiling And
Roof Diaphragm Connections.
ROOF PITCH: 6112
CEILING PITCH: 3112
TOP CHORD SIZE: 2 X 4
BOTTOM CHORD SIZE: 2 X 4
OVERHANG LENGTH: 16"
END CUT: Plumb
CANTILEVER: —
TRUSS SPACING: 24"
BUILDING CODE: FBC202D
BEARING HEIGHT SCHEDULE
Adams Homes
PROJECT: Inge Family
MODEL: 1780 A 3CAR BLK
ADDRESS: 1 8601 MERANO AVE
LOT I BLOCK: 66/1
SION:I WATERSTONE
CITY: FORT PIERCE
DRAWN BY: KSANCHEZ
JOB # : 1 2813124
DATE: 07/0512021 1 SCALE: I NTS
PLAN DATE: 1 2021
REVISIONS:
1.
2.
3.
4.
4408 Airport Road
Plant City, FL 33563
Ph.(813) 305-1300
Fax (813) 305-1301